The expert in Aircraft power

Pre-Conditioned Air units


Fixed PCA units

LDX
Lebrun Direct eXpansion Pre-Conditioned Air units
LEBRUN LDX Point-Of-Use ground or bridge mounted Pre-Conditioned Air units were specifically developed to meet the
requirements of airports in taking over the functions of the aircraft APU while the aircraft is parked at the gate. This alternative
drastically reduces CO2/NOx emissions and noise level while leading to major savings in fuel and on the maintenance cost
of the on-board APU. These units will automatically maintain the appropriate temperature inside the cockpit, the cabin and
the electronic compartment of any parked aircraft during pre-flight servicing, loading and maintenance (AIRBUS, BOEING,
EMBRAER, FALCON).
LEBRUN LDX PCA units are designed for ground or bridge mounting, parking areas or for hangar applications
(maintenance).
LEBRUN LDX PCA units are designed for existing, refurbished, extended or new terminals.
Main advantages of LEBRUN LDX PCA units are:
High performances: refrigeration capacity, energy efficiency, low noise level.
Low Total Cost of Ownership (TCO).
High Reliability.
Low maintenance, easy access to all components.
Easy installation, commissioning and operation.
LEBRUN commits to the highest performances (verified in test room at Customer site conditions), cabin
temperature achievement, pressure and temperature losses in the hoses, free online assistance.
Key Words: Performance, Efficiency (COP), Reliability, Low maintenance, Compliance with latest requirements
of aircraft (AIRBUS, BOEING, EMBRAER, FALCON).
Purpose: From narrow body to jumbo aircraft (A380 ready), ground or bridge mounted.

GUINAULT S.A
95 Rue du Rond dEau
45590 Saint-Cyr-en-Val - FRANCE
Tel: +33 2 38 63 84 00
E-mail : info@guinault.com

GUINAULT-LEBRUN
Rue de Bettingen Nr4
8362 Grass - LUXEMBURG

www.guinault-lebrun.com

LEBRUN S.A
Rue Grard 15
7020 Nimy - BELGIUM
Tel: +32 65 40 30 30
Email: info@lebrun.eu

The expert in Aircraft power

LDX15

LDX20

LDX40

LDX65

AIRCRAFT TYPES

C (737, A320)
D (B767, A300)
E (B777, B747, A330,A340, A350)
F (B787, A380)

COOLING FEATURES

Minimum Air Flow

0,5 kg/sec

0,8 kg/sec

1,5 kg/sec

1,5 kg/sec

Maximum Air Flow

2,0 kg/sec

2,6 kg/sec

5,0 kg/sec

6,5 kg/sec

Maximum Pressure

6000 Pa

8600 Pa

10000 Pa

13000 Pa

Air Temperature delivery

-5 / +5C

-5 / +5C

-5 / +5C

-5 / +5C

< 125 A

< 150 A

< 300 A

< 500 A

ELECTRICAL CURRENT CONSUMPTION

Consumption in cooling mode

DIMENSIONS and WEIGHT

Ground mounted
LxWxH - Weight

2608x2500x2118 mm
2.500 kg

3800x2500x2780 mm
3.600 kg

4300x2500x2780 mm
6.500 Kg

5500x2500x2780 mm
9.000 Kg

Bridge mounted
LxWxH - Weight

3500x2500x1600 mm
2.750 kg

4300x2500x1600 mm
3.850 kg

< 80 dB(A)

< 80 dB(A)

< 80 dB(A)

< 85 dB(A)

SOUND PRESSURE LEVEL

At 3 meters distance, free field

STANDARD FEATURES

Feet with silent blocks (ground mounted PCA units)


Frame and panels in galvanized and painted steel
Panels fitted with sound insulation
RAL 9010 as Standard. Other upon request

Screw compressor (low vibrations, no overhaul maintenance before


100 000 hours)
R134a refrigerant
Electrically operated expansion valves
Sight glass
Filter dryer

2 stages filtration G4 + F7 with pressostat control


High efficiency centrifugal blower
Air outlet: one or two 14/18 outlets
Automatic airflow adjustment

Variable frequency drives on compressor, condenser fans and blower


380 to 460V, 3 Phases, grid frequency of 50 or 60Hz and ground

No condensate pump
Stainless steel condensate pan

Smart control:
- touchscreen for easy operation and maintenance
- management of all aircraft curves and restrictions
- management of airflows, pressures, temperatures
- management of sensors, valves...

Automatic or manual mode selection

MODBUS TCP/IP (RS485 protocol) for BMS


connection or any other protocol

CE Certificate
Compliance with:
Machinery Directive 2006/42/EC,
EMC Directive 2004/108/EC
Low Voltage Directive (LVD) 2006/95/EC

High & low pressostats


Compressor Overheating
Oil low level / low temperature

Sand louvers
Any other RAL color
Ultra low noise

SAFETY FEATURES

Reversed phase protection


Air outlet over heating
Smoke detector
Overpressure

STANDARD OPTIONS

Refrigerant leak detector


Remote control panel
Heating mode
Special coating protection for coils

Specifications subjected to modifications without notice

www.guinault-lebrun.com