1- LST RTTST
Note
None.
Parameters
ID
Name
Description
Example
Example 1: To list the information about the routine E1/T1 test whose task ID
is 2, run the following command:
LST RTTST:TID=2;
The result is shown as follows:
+++
HUAWEI
2008-05-17 12:05:39
O&M
#28
%% LST RTTST:TID=2;%%
RETCODE = 0 Operation succeeded
Routine Test Task
-----------------
Task ID
Task State
Test Item
Cabinet No.
Subrack No.
Slot No.
Subboard Type
Port No.
Start Time
End Time
Test Period(min)
Test Duration(min)
=
=
=
=
=
=
=
=
=
=
=
=
2
IDLE
E1T1 Test
0
0
0
E1 Cover Board
0
2008-05-01 22:00:00
2008-06-01 22:30:00
40
1
(Number of results = 1)
---
END
Example 2: To list the information about the routine RTWP test whose task ID
is 255, run the following command:
LST RTTST:TID=255;
The result is shown as follows:
LST RTTST: TID=255;
+++
HUAWEI
2010-04-07 11:15:03
O&M
#182
%%LST RTTST: TID=255;%%
RETCODE = 0 Operation succeeded.
Routine Test Task
----------------Task ID
Task State
Test Item
Detection Type
Change Time (S)
Increase/Decrease Range (0.1dB)
Upper Limit (0.1dBm)
Lower Limit (0.1dBm)
(Number of results = 1)
---
=
=
=
=
=
=
=
=
255
TESTING
RTWP Test
Change Threshold
5
10
-720
-1120
END
Output Description
Field
Description
Task ID
Task State
Test Item
Cabinet No.
Subrack No.
Slot No.
Subboard Type
Port No.
Test Period(min)
Test Duration(min)
Detection Type
Change Time(s)
Indicates the size of the time window. This parameter is valid when
Detection Type includes CHANGE or THRESHOLD.
Increase/Decrease
Range(0.1dB)
Upper Limit(0.1dBm)
Lower Limit(0.1dBm)
Note
All routine test results saved on an NE will be lost when the NE restarts.
The number of RTWP routine test result executed is fixed to 0, but this data cannot be
used for the analysis of the RTWP performance test result. To view the actual RTWP,
upload the routing RTWP test log file from the base station.
Parameters
ID
Name
Description
Example
Example 1: To list the results of the routine E1/T1 test whose task ID is 2,
run the following command:
LST RTTSTRESULT: TID=2;
The result is shown as follows:
+++
HUAWEI
2008-05-17 12:05:39
O&M
#28
%% LST RTTSTRESULT:TID=2;%%
RETCODE = 0 Succeed.
E1T1 Test Result
---------------Task ID = 2
Cabinet No. = 0
Subrack No. = 0
Slot No. = 0
Subboard Type = E1 Cover Board
Port No. = 1
Execution Result = Succeeded
Test Start Time = 2008-05-03 18:30:00
Test End Time = 2008-05-03 18:40:00
Line Conflicting Error Rate = 0.002
Framing Error Rate = 0.001
CRC Error Rate = 0.0001
EBit Error Rate(E1)/Error Block Rate(T1) = 0.05
(Number of results = 1)
To be continued...
---
END
+++
HUAWEI
2008-05-17 12:05:39
O&M
#28
%% LST RTTSTRESULT:TID=2;%%
RETCODE = 0 Operation succeeded
2 reports in total
--END
Example 2: To list the results of the routine optical port test whose task ID
is 4, run the following command:
LST RTTSTRESULT: TID=4;
The result is shown as follows:
LST RTTSTRESULT: TID=4;
+++
HUAWEI
2010-04-07 11:24:29
O&M
#223
%%LST RTTSTRESULT: TID=4;%%
RETCODE = 0 Operation succeeded.
STM1 Test Result
---------------Task ID
Cabinet No.
Subrack No.
Slot No.
Subboard Type
STM No.
Test Mode
Test Start Time
Test End Time
Execution Result
Out of Frame Event Rate
Regenerator Section Block Error Rate
Multiplex Section Block Error Rate
Multiplex Section Far End Block Error Rate
High Order Path Block Error Rate
High Order Path Far End Block Error Rate
Loss of Cell Delineation Event Rate
Rx Corrected HEC Error Rate
Rx Uncorrectable HEC Error Rate
Nonmatched Cell Rate
Tx Cell Number
Rx Cell Number
Lower Order Path Block Error Rate
Lower Order Path Far End Block Error Rate
(Number of results = 1)
To be continued...
---
END
+++
HUAWEI
2010-04-07 11:24:29
O&M
#223
%%LST RTTSTRESULT: TID=4;%%
RETCODE = 0 Operation succeeded.
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
4
0
0
0
Unchannelled Cover Board
0
Group Type
2010-04-07 11:23:17
2010-04-07 11:24:17
Succeeded
0.3000000001
0.3000000001
0.3000000001
0.3000000001
0.3000000001
0.3000000001
0.3000000001
0.3000000001
0.3000000001
0.3000000001
1000
2000
0.3000000001
0.3000000001
2 reports in total
--END
Output Description
Field
Description
Task ID
Cabinet No.
Subrack No.
Slot No.
Subboard Type
Port No.
Execution Result
STM No.
Test Mode
Number of Tx Cells
Number of Rx Cells
Note
The time and date parameters indicate the time and date of the BS rather than the time
and date of the LMT.
Parameters
ID
Name
Description
CN
Cabinet No.
SN
Slot No.
CLS Subboard
Type
PN
Port No.
SD
Start Date
ST
Start Time
ED
End Date
ET
End Time
Test Period
TD
Example
To start the routine E1/T1 performance test with the parameters as follows:
Cabinet No.: 0, Subrack No.: 0, Slot No.: 0, Subboard Type: E1 Cover Board,
Port No.: 0, Start Date: 2010&07&01, Start Time: 00&00&00, End Date:
2010&07&02, End Time: 00&00&00, Test Period: 60, Test Duration: 5, run the
following command:
STR E1T1RTTST: CN=0, SRN=0, SN=0, CLS=E1_COVERBOARD,PN=0, SD=2010&07&01,
ST=00&00&00, ED=2010&07&02, ET=00&00&00, TP=60, TD=5;
The result is shown as follows:
+++
HUAWEI
2008-05-17 12:05:39
O&M
#28
%%STR E1T1RTTST: CN=0, SRN=0, SN=0, CLS=E1_COVERBOARD, PN=0, SD=2010&07&01,
ST=00&00&00, ED=2010&07&02, ET=00&00&00, TP=60, TD=5;%%
RETCODE = 0 Operation succeeded
Start E1T1 Routine Test Report
-----------------------------Task ID = 2
(Number of results = 1)
---
END
Output Description
Field
Description
Note
When a RTWP routine test is started, all users can query or stop the test, but no user can
start the test again.
A maximum of 20 routine tests can be conducted at the same time in the system,
including the E1/T1 performance routine test, optical port line performance routine test,
and RTWP routine test.
A routine test is not conducted for a single user but effective to all users.
Parameters
ID
Name
Description
TYPE
Detection Type
CHT
Change Time
RANGE Increase/Decrease
Range
UPL
Upper Limit
Lower Limit
Example
To start the routine RTWP performance test with the parameters as follows:
Detection Type: CHANGE, Change Time: 300, Increase/Decrease Range: 100, run
the following command:
STR RTWPRTTST:TYPE=CHANGE,CHT=300,RANGE=100;
The result is shown as follows:
+++
HUAWEI
2008-05-17 12:05:39
O&M
#28
%% STR RTWPRTTST:TYPE=CHANGE,CHT=300,RANGE=100;%%
RETCODE = 0 Operation succeeded
Start RTWP Routine Test Report
-----------------------------Task ID = 2
(Number of results = 1)
--END
Output Description
Field
Description
Function
Use this command to stop the specified routine test. The system actively reports each result of
the routine test, before reporting the command execution success message, which indicates the
number of results of the executed routine test.
Note
None.
Parameters
ID
Name
Description
Example
Example 1: To stop the routine E1/T1 test whose task ID is 2, run the
following command:
STP RTTST:TID=2;
The result is shown as follows:
+++
HUAWEI
2008-05-17 12:05:39
O&M
#28
%%STP RTTST:TID=2;%%
RETCODE = 0 Succeed.
E1T1 Test Result
---------------Task ID
Cabinet No.
Subrack No.
Slot No.
Subboard Type
Port No.
Execution Result
Test Start Time
Test End Time
Line Conflicting Error Rate
Framing Error Rate
=
=
=
=
=
=
=
=
=
=
=
2
0
0
0
E1 Cover Board
1
Succeeded
2008-05-03 18:30:00
2008-05-03 18:40:00
0.002
0.001
=
=
0.0001
0.05
To be continued...
---
END
+++
HUAWEI
2008-05-17 12:05:39
O&M
#28
%%STP RTTST:TID=2;%%
RETCODE = 0 Operation succeeded
Number of Test Result Executed
-----------------------------Number of Test Result Executed
(Number of results = 1)
2 reports in total
--END
Example 2: To stop the routine optical port test whose task ID is 4, run the
following command:
STP RTTST:TID=4;
The result is shown as follows:
STP RTTST: TID=4;
+++
HUAWEI
2010-04-07 11:24:49
O&M
#226
%%STP RTTST: TID=4;%%
RETCODE = 0 Operation succeeded.
STM1 Test Result
---------------Task ID
Cabinet No.
Subrack No.
Slot No.
Subboard Type
STM No.
Test Mode
Test Start Time
Test End Time
Execution Result
Out of Frame Event Rate
Regenerator Section Block Error Rate
Multiplex Section Block Error Rate
Multiplex Section Far End Block Error Rate
High Order Path Block Error Rate
High Order Path Far End Block Error Rate
Loss of Cell Delineation Event Rate
Rx Corrected HEC Error Rate
Rx Uncorrectable HEC Error Rate
Nonmatched Cell Rate
Tx Cell Number
Rx Cell Number
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
4
0
0
0
Unchannelled Cover Board
0
Group Type
2010-04-07 11:23:17
2010-04-07 11:24:17
Succeeded
0.3000000001
0.3000000001
0.3000000001
0.3000000001
0.3000000001
0.3000000001
0.3000000001
0.3000000001
0.3000000001
0.3000000001
1000
2000
=
=
0.3000000001
0.3000000001
To be continued...
---
END
+++
HUAWEI
2010-04-07 11:24:49
O&M
#226
%%STP RTTST: TID=4;%%
RETCODE = 0 Operation succeeded.
Number of Test Result Executed
-----------------------------Number of Test Result Executed
(Number of results = 1)
2 reports in total
--END
Output Description
Field
Description
Task ID
Cabinet No.
Subrack No.
Slot No.
Subboard Type
Port No.
Execution Result
STM No.
Test Mode
Number of Tx Cells
Number of Rx Cells