Sei sulla pagina 1di 7

Bill of Material

Document No:

Project : General Project Francis Turbine


Project Code:
Item Turbine Auxiliary Control And Governor
Panel(TAGP)
Rev Part Description
Nomen
0
No

Ref

Make

Rating/Scale Range etc

Detail

Qty/
Unit

Master Trip Relay

86TU

Areva/Alst
om

Aux voltage : 110V DC, 6NO+2NC


Electrical reset contacts, with flag,
case size : NH
Dim. H-124xW153xD-128mm
Cutout-H-116mmXw145mm

MVAJH

Digital Speed Monitor


Relay with
Proximity Sensor

SM

Omron

1) Supply Voltage: 24V DC.


Sensor
Input : NPN input/Voltage input pulse
I/P
O/P 4-20mA
2) Optional Boards
4 Relay output board
Size 96x48mm
% Indicator 24V DC
Liner Inputs 4-20mA
LOOPIN, LOOPOUT
2 nos. Relay Out put
Size 96x48x248mm
12 Windows, 110V DC
Big Window- Size 32X32mm
Colour-RED for Trip-16Nos.
AMBER for Alarm-16Nos.

K3HB-RNB
DC/24

Digital Position Indicator


GUIDE VANE

GVI%

Masibus/O
mron/Redli
on

Annunciator for Trip &


Alarm

30A

Minilec

Auto/Test Switch

SW1

SALZER/

Compiled by
Checked by
Approved by

Date

Rev

Date

2 Pole Position stayput 22.5dia, 6A


Revision

Total
QTY

Remarks

With proximity
sensor model no.

E2A-M12KS04M1-C1
XS2F-D422GCO-A2

K34-C2
LC5296H

MBAS0600
3

12 Window

22.5Dia

DC SWITCH

Date


Bill of Material

Document No:

Project : General Project Francis Turbine


Project Code:
Item Turbine Auxiliary Control And Governor
Panel(TAGP)
Rev Part Description
Nomen
0
No
110V DC, CW ON/OFF
Switch
110V DC, GLOP
ON/OFF Switch
110V DC,
OPU System ON/OFF
Switch
110V DC, Spring Return
Switch
Speed/Load Raise/lower
Selector switch

SW2

Brake Apply/Release
SelectActuator

SW7

Guide vane
Open/CloseSelect
Actuator

SW5/
SW8

Push buttons
ANN. Accept
ANN. Test
ANN. Reset

Compiled by
Checked by
Approved by

SW3
SW4

SW6

Ref

Make

Rating/Scale Range etc

Detail

2 Pole Position stayput 22.5dia, 6A

22.5Dia

DC SWITCH

2 Pole Position stayput 22.5dia, 6A

22.5Dia

DC SWITCH

2 Pole Position stayput 22.5dia, 6A

22.5Dia

DC SWITCH

2 way with spring at centre position


NO element in each position

22.5Dia

2 way with spring at centre position


NO element in each position

22.5Dia

Teknic

2 way with spring at centre position


NO element in each position

22.5Dia

Teknic

22.5 Dia
BLACK-with 1 NO Element
BLUE-with 1 NO Element
YELLOW-with 1 NO Element

22.5Dia

Siemens
SALZER/
Siemens
SALZER/
Siemens
SALZER/
Siemens
SALZER/
Siemens

PB1
PB2
PB3
Date

Rev

Date

Revision

Qty/
Unit

Remarks

DC SWITCH
1

1
1
1
Date

Total
QTY


Bill of Material

Document No:

Project : General Project Francis Turbine


Project Code:
Item Turbine Auxiliary Control And Governor
Panel(TAGP)
Rev Part Description
Nomen
0
No
M/C Auto Start
M/C Auto Stop
By-pass Valve Open
By-pass Valve close
MIV-Open
MIV-Close
Spare
Spare

10

Ref

Make

PB4
PB5
PB6
PB7
PB8
PB9
PB11
PB12

Emergency Stop

DC/DC Converter

Teknic

12

Hooter for DC fail

13

Electronic Hooter (Buzzer)

14

Miniature Circuit Breaker

Compiled by
Checked by
Approved by

Date

PS

Rating/Scale Range etc

Detail

22.5 Dia
RED-2NO & 1NC Element
Stay-put Type Mushroom head
Press to Lock Turn to Release

Qty/
Unit

110V DC/24V DC,


20A - 25A with Fan

Edison

240V AC

Captain

110V DC, Door Mounting

MCB1

ABB/
legrand

110V DC, 20 Amps-2Pole

Date

Revision

Remarks

22.5Dia

Pheonix
(Quint)

Rev

Total
QTY

1
1
1
1
1
1
1
1

GREEN-with 1 NO Element
RED- with 1 NO Element
GREEN-with 1 NO Element
RED- with 1 NO Element
GREEN-with 1 NO Element
RED-with 1 NC Element
GREEN-with 1 NO Element
RED-with 1 NO Element

EPB

11

S 282 UC-K
20
Date

For DC Fail
Annunciation
For Fault Ann.
(Mounted on Rear
door)


Bill of Material

Document No:

Project : General Project Francis Turbine


Project Code:
Item Turbine Auxiliary Control And Governor
Panel(TAGP)
Rev Part Description
Nomen
0
No

Ref

Make

Rating/Scale Range etc

Detail

Qty/
Unit

S 282 UC-K
6
S 281 UC-K
10
S272-C 20
S272-C 6
S272-C 10

4
3

15

Miniature Circuit Breaker

MCB2-5
MCB10,
11,12

ABB

110V DC, 6 Amps-2Pole


110V DC, 10 Amps-1Pole

16

Miniature Circuit Breaker

MCB6
MCB7,8
MCB9

ABB

240V AC, 20 Amps-2Pole


240V AC, 6 Amps-2Pole
240V AC, 10 Amps-2Pole

17

Door Limit Switch

DS1

Teknic
Euchner

10A, 230V AC, Roller Type

NG1KB510

18

Panel lamp

CFL

Philips

Compact Fluorescent lamp with


Fitting. 9Watt, 240V. AC

19

Thermo -Stat

HTH

Girish

0-60 C, 15Amps. 240V AC

20

Space heater

HSH

KSI

80 Watts, 240V, AC

21

Toggle Switch

TG1

Kaycee

1Pole OFF/ON, 6A

KT 1621
BY

22

Power socket with switch


built in fuse
Diode TB

PS1

Anchor

D1-D29

Elmex

15Amps, 3pin, 240V AC, With LED


Indication
Dual Diode Cathode Common

23

Compiled by
Checked by
Approved by

Date

Rev

Date

Revision

KUDD4
Date

Total
QTY

Remarks

1
2
1

Qty shall be as per


Bill of Material

Document No:

Project : General Project Francis Turbine


Project Code:
Item Turbine Auxiliary Control And Governor
Panel(TAGP)
Rev Part Description
Nomen
0
No
24

Control TB

Ref

Make

Rating/Scale Range etc

Detail

Eelmex

Earth Bus

26

Wiring
Auxiliary Supply ckt.
240V, AC Ckt.

Copper, 1Rx50x10 mm
1 Sq mm, +Ve-Red, -Ve-blue
1.5 Sq mm, Phase yellow, neutral-light
blue

FRLS
FRLS

Analog Signal Ckt.


2C x 0.75 Sq mm (screened)
Brown/White
4C x 0.75 Sq mm (screened)
Brown/White/Yellow/Green
1 Sq mm, black

Binary signal ckt.


1. Interlocks / XA to Relay
Compiled by
Checked by
Approved by

Date

Rev

Date

Total
QTY
drawing.

XA
XB
XC
TB
XS
XG
XA1
XA2
XA3
XP
XD
25

Qty/
Unit

Revision

Date

Remarks


Bill of Material

Document No:

Project : General Project Francis Turbine


Project Code:
Item Turbine Auxiliary Control And Governor
Panel(TAGP)
Rev Part Description
Nomen
0
No

Ref

Make

Rating/Scale Range etc

Detail

Qty/
Unit

Total
QTY

0.75 Sq mm, Pink

2. Annunciator
(Alarm/Trip)
Windows (30A)
Finolex
Finolex
Lapp
(unitronic)

27

CRCA Sheet metal construction,


Free standing with
1. All Load Bearing Members
32mm Thick
2. Front covers 2mm Thick
3. Rear Doors 2mm Thick
4. Partition 1.6mm Thick
5. Removable Gland Plate
6. Colour - RAL-7035
Powder coated Structure finish
7. Degree of Protection IP 55
8. lifting arrangement
9. 100mm Base channel

Fabricated panel,
removable gland plates,
base channel

Compiled by
Checked by
Approved by

Date

Rev

Date

Revision

Date

Remarks


Bill of Material

Document No:

Project : General Project Francis Turbine


Project Code:
Item Turbine Auxiliary Control And Governor
Panel(TAGP)
Rev Part Description
Nomen
0
No

Ref

Make

Rating/Scale Range etc

Detail

Qty/
Unit

Total
QTY

Remarks

10. 15mm AVM Pad

Note:

Any other item required other than mentioned above required for completion of the system shall be supplied by supplier without any extra charges.
All equipments shall operate satisfactorily in ambient temperature up to 45C without air conditioning.
Pilot devices such as selector switches, push button stations, and thermostat, will be of heavy duty type.
All CT & PT connections inside panels will be done with of 2.5sq mm.
CT PT wiring will be done with colored wiring only
Make of the wiring shall be Finolex/Lapp FRLS Cable.
The type of turbine is Horizontal Francis.

Contactor and interposing relay will be as per agreed BOM.

Compiled by
Checked by
Approved by

Date

Rev

Date

Revision

Date