PROGRAM DESCRIPTION SHEET

07/15/11

RATE

7SEG0147

UP

Processor:
Target Display:

PARALELL

68HC05C8
402B

Path: N:\RELEASED\6805
Source Loc: N:\6805C
Compiled w/: COSMIC
Language: C
Based on: RATE402
Description: 1-digit to 16-digit general rate counter (with ability to expand as needed for custom rates)
Custom Rates for Rehau and Bruce Hardwood Floors. See dip switch settings for more Info.
Control Bd:

1700-402

Baud Rate In:


Baud Rate Out:
Input Protocol:
Output Protocol:
Other inputs:
Other outputs:
Dip Switches:

Address switch is SW4:


ADDRESS switches 1 & 2 control the refresh rate
1 OFF and 2 OFF = once per second
1 ON and 2 OFF = once per ten seconds
1 OFF and 2 ON = once per 30 seconds
1 ON and 2 ON = once per minute
ADDRESS switches 3 through 8 control the scaling factor
- 8 OFF, 7 OFF, 6 OFF, 5 OFF, 4 OFF, & 3 OFF = pulses per second
- 8 OFF, 7 OFF, 6 OFF, 5 OFF, 4 OFF, & 3 ON = pulses per minute(STANDARD)
- 8 OFF, 7 OFF, 6 OFF, 5 OFF, 4 ON, & 3 OFF = pulses per hour
- 8 OFF, 7 OFF, 6 OFF, 5 OFF, 4 ON, & 3 ON = pulses per day
- 8 OFF, 7 OFF, 6 ON, 5 OFF, 4 ON, & 3 OFF = Special for Rehau(encoder output of 23 pulses
per revolution/Feet Per Minute)
- 8 OFF, 7 OFF, 6 ON, 5 OFF, 4 ON, & 3 ON = Special for Bruce Hardwood Floors(encoder output
of 2 pulses per revolution/Feet Per Minute)
(other settings to be defined as needed)
- 8 OFF, 7 OFF, 6 ON, 5 ON, 4 OFF, & 3 OFF = SPECIAL FOR CHANNEL CORP. 863 PPM = 4.2;
2588PPM = 12.6
NOTE: DISPLAY MUST HAVE FIXED DECIMAL POINT(X X X . X) FOR CHANNEL CORP.
- 8 OFF, 7 OFF, 6 ON, 5 ON, 4 OFF, & 3 ON = SPECIAL FOR JJosephson. 180PPM = 1,
180PPS=60

FUNCTION SWITCH is SW2:


FUNCTION switches 1 through 3 control quantity of digits
1 OFF, 2 OFF, & 3 OFF = 2 (or 1) digits
1 ON, 2 OFF, & 3 OFF = 4 (or 3) digits (CHANNEL CORP)
1 OFF, 2 ON, & 3 OFF = 6 (or 5) digits
1 ON, 2 ON, & 3 OFF = 8 (or 7) digits
1 OFF, 2 OFF, & 3 ON = 10 (or 9) digits
1 ON, 2 OFF, & 3 ON = 12 (or 11) digits
1 OFF, 2 ON, & 3 ON = 14 (or 13) digits
1 ON, 2 ON, & 3 ON = 16 (or 15) digits
FUNCTION switches 4 & 5 control trailing zero's
4 OFF and 5 OFF = none( CHANNEL CORP)
4 ON and 5 OFF = one
4 OFF and 5 ON = two
4 ON and 5 ON = three
Date In:
Comment:
Logic:

04/06/01
Requires 4 meg Hz crystal, IRQ opto
For period of first refresh interval, the display will show the counts received (updated every 1/2
second). After the first refresh interval, it will show the rate (scaled as needed) and updated once
every refresh interval.

Released: 04/06/01
Who?: RMH
Tester: TECHS

Revision History
Revision

Date

Who?

What?

04/06/01

COM

Initial release