Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
E1 CSU/DSU
Model 1500 / Model 500
(Stand Alone)
Installation Guide
TABLE OF CONTENTS
1. INSTALLATION................................................................................... 1
1.1 Unpacking.............................................................................................................. 1
1.2 Site Selection ........................................................................................................ 1
1.3. Mechanical and Electrical Installation ............................................................. 1
1.3.1.
Mechanical Installation............................................................................ 1
1.3.2.
Electrical Installation ............................................................................... 3
1.4. Configuration Setting ...................................................................................... 11
1.4.1.
Hardware Configuration Setting............................................................ 11
1.4.2.
Software Configuration Setting ............................................................. 11
1.5. Self-Test ............................................................................................................ 13
FIGURES
Figure 1- 1 Loop-E E1 CSU/DSU Front Panel View --------------------------------------- 1
Figure 1- 2 Loop-E CSU/DSU Rear Panel ---------------------------------------------------- 2
Figure 1- 3 Loop-E 1500 Stand Alone Internal Jumpter Setting ---------------------- 2
TABLES
Table 1 - 1 Shipping Material List--------------------------------------------------------------- 1
Table 1 - 2 Loop-E 1500 Stand Alone Configuration------------------------------------- 2
Table 1 - 3 RJ11 Console Port ------------------------------------------------------------------ 3
Table 1 - 4 RJ11 to DB25P (Male) Conversion Cable ------------------------------------ 3
Table 1 - 5 RJ11 to DB9S (Female) Conversion Cable ---------------------------------- 3
Table 1 - 6 Console port Conversion Cable (RJ11 to DB25) -------------------------- 3
Table 1 - 7 RJ48 Line Connector --------------------------------------------------------------- 4
Table 1 - 8 V.35/M34 DTE Port Pin Definition ---------------------------------------------- 5
Table 1 - 9 V.35/DB25 DTE Port Pin Definition--------------------------------------------- 6
Table 1 - 10 EIA530/DB25 DTE Port Pin Definition --------------------------------------- 7
Table 1 - 11 X.21/DB15 DTE Port Pin Definition ------------------------------------------- 8
Table 1 - 12 RS232/DB25 DTE Port Pin Definition ---------------------------------------- 9
Table 1 - 13 RS449/DB37 DTE Port Pin Definition ---------------------------------------10
Table 1 - 14 Default Software Configuration ----------------------------------------------12
-i-
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
1. INSTALLATION
CAUTION:
Never install telephone wiring during a lightning storm.
Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
Never touch un-insulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
Use caution when installing or modifying telephone lines.
1.1 Unpacking
This product is shipped in a complete package which contains Loop-E E1 CSU/DSU and accessories.Check
the shipping material against Table 1-1 Shipping Material List.
Table 1 - 1 Shipping Material List
Description
Loop-E FE1 CSU/DSU
User's Manual
AC Power Cord
Console Port Cable RJ 11 to DB25
(Choose one)
RJ 11 to DB 9S
Item
1
1
1
1
1
-1-
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
Loop-E E1 CSU/DSU Stand-Alone version is a desk top unit, which is stackable. The front panel is shown in
Figure 1-1, and the rear panel is shown in Figure 1-2.
J5
JG
2 1 3
J6
2 1 3
J4
J7
3 1 2 3 1 2
3 1 2
3 1 2
J
1
Main Board
J
2
J
3
3 1 2
-2-
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
Signal
Unassigned
Data Carrier Detect
Transmit Data
Receive Data
Signal Ground
Data Terminal Ready
Source
DCE
DTE
DCE
DTE
Signal
Data Carrier Detect
Transmit Data
Receive Data
Signal Ground
Data terminal Ready
DB25 Connector
Pin Number
8
2
3
7
20
-3-
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
Signal
Receive Ring
Receive Tip
Unassigned
Transmit Ring
Transmit Tip
Unassigned
Shield Ground
Shield Ground
Signal Direction
From E1 Network
From E1 Network
To E1 Network
To E1 Network
The DTE port is configured as a DCE device. There are 6 different DTE boards: V.35/M34, V.35/DB25,
EIA530/DB25, X.21/DB15, RS232/DB25, and RS449/DB37. Pin definitions are defined in Tables 1-5 to 113.
-4-
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
Signal
Source
Cable Shield
Signal Ground
Request To Send
DTE
Clear To Send
DCE
DCE
DCE
DTE
Unassigned
Unassigned
Unassigned
Unassigned
Unassigned
Transmit Data
DTE
Receive Data
DCE
DTE
DCE
External Clock
DTE
Receive Clock
DCE
DTE
DCE
Transmit Clock
DCE
Unassigned
AA
BB
Unassigned
CC
Unassigned
DD
Unassigned
EE
Unassigned
FF
Unassigned
HH
Unassigned
JJ
Unassigned
KK
Unassigned
LL
Unassigned
MM
Unassigned
NN
Unassigned
-5-
DCE
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
Signal
Source
Cable Shield
Transmit Data
DTE
Receive Data
DCE
Request To Send
DTE
Clear To Send
DCE
DCE
Signal Ground
DCE
DCE
10
Unassigned
11
DTE
12
DCE
13
Unassigned
14
DTE
15
Transmit Clock
DCE
16
DCE
17
Receive Clock
DCE
18
Unassigned
19
Unassigned
20
21
Unassigned
22
Unassigned
23
Unassigned
24
External Clock
25
Unassigned
DTE
DTE
-6-
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
Signal
Source
Cable Shield
Transmit Data
DTE
Receive Data
DCE
Request To Send
DTE
Clear To Send
DCE
DCE
Signal Ground
DCE
DCE
10
DCE
11
DTE
12
DCE
13
DCE
14
DTE
15
Transmit Clock
DCE
16
DCE
17
Receive Clock
DCE
18
Local Loopback
DTE
19
DTE
20
DTE
21
Remote Loopback
DTE
22
DCE
23
DTE
24
External Clock
DTE
25
Test Mode
DCE
-7-
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
Signal
Source
Cable Shield
Transmit Data
DTE
Control
DTE
Receive Data
DCE
Indication
DCE
Signal Timing
DCE
External Clock
DTE
Signal Ground
DTE
10
Control Return
DTE
11
DCE
12
Indication Return
DCE
13
DCE
14
DTE
15
Unassigned
-8-
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
Signal
Source
Cable Shield
Transmit Data
DTE
Receive Data
DCE
Request To Send
DTE
Clear To Send
DCE
DCE
Signal Ground
Unassigned
10
Unassigned
11
Unassigned
12
Unassigned
13
Unassigned
14
Unassigned
15
Transmit Clock
16
Unassigned
17
Receive Clock
DCE
18
Local Loopback
DTE
19
Unassigned
20
DTE
21
Remote Loopback
DTE
22
Unassigned
23
Unassigned
24
External Clock
DTE
25
Test Mode
DCE
DCE
DCE
-9-
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
Signal
Source
Cable Shield
Unassigned
Unassigned
Transmit Data
DTE
Transmit Clock
DCE
Receive Data
DCE
Request To Send
DTE
Receive Clock
DCE
Clear To Send
DCE
10
Local Loopback
DTE
11
DCE
12
DTE
13
DCE
14
Remote Loopback
DTE
15
Unassigned
16
Unassigned
17
External Clock
DTE
18
Test Mode
DCE
19
Signal Ground
20
Unassigned
21
Unassigned
22
DTE
23
DCE
24
DCE
25
DTE
26
DCE
27
DCE
28
Unassigned
29
DCE
30
DTE
31
DCE
32
Unassigned
33
Unassigned
34
Unassigned
35
36
Unassigned
37
Unassigned
- 10 -
DTE
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
- 11 -
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
Default
Baud Rate
Data Bit
Stop Bit
Parity Bit
XON-XOFF
Interface
9600
8
1
NONE
OFF
TERMINAL
E1 Line Item
Default
Code
CRC
RAI
FDL
Idle Code
Frame
HDB3
ON
ON
ON
0xD5
ON
DTE Port
Default
Rate
Clock
Data
RTS
TTM
64KxN
NORMAL
NORMAL
ACTIVE
OFF
Active Map
Default
MAP1
MAP2
Switch MAP1:
MAP2:
Master Clock
2nd Clock
Password
all idle
all idle
(00:00 - 12:00)
(12:00 - 00:00)
Line Clock
Line Clock
Disable
Alarm Threshold
Alarm Enable
Alarm Dial-out
BPV, Line
ES, Line
UAS, Line
CS, Line
Default
Disable
Disable
10E- 5
1
1
1
Dial Out
Primary Dial String
Start Time
Stop Time
Secondary Dial String
Start Time
Stop Time
Inactivity Time-out
Password
Device Name
ATDT
08:00
07:59
ATDT
08:00
07:59
0 Minutes
LOOP
LOOP-E-01
Default
- 12 -
Loop-ETM E1 CSU/DSU Model 1500/ Model 500 Stand Alone Installation Guide
1.5. Self-Test
At system power up, a complete self-test routine is run to check all I/O ports, read/write memory, and data
paths to validate system integrity. During the system self test, "Testing" message is shown on the upper line
of the LCD display. The software release version and date code is shown on the lower line of the LCD
display. If an error is found, FAIL is shown in the upper right corner of the LCD display and a dedicated error
message is shown on the lower line. Users may press ESC, left arrow ( < ), right arrow ( > ), and ENTER
key in this order to read a specific error code. If no error is found, the LCD display will show "PASS" in the
upper right corner of the LCD display followed by a Main Menu. After installation see step-by-step guide for
the configuration of the CSU/DSU.
- 13 -