Sei sulla pagina 1di 5

PROFIS Anchor 2.1.4 www.hilti.

at
Company: CHIRAG ALUMINUM
Specifier:
Address:
Phone I Fax: - | -
E-Mail:
Page:
Project: CANOPY
Sub-Project I Pos. No.:
Date: 9/6/2014
Specifier's comments:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1. Input data
Anchor type and diameter: HIT-HY 150 MAX + HAS(-E) (5.8), M12
Effective embedment depth: h
ef
= 110 mm
Material: 5.8
Evaluation Service Report::
Issued I Valid: - | -
Proof: design method Engineering judgement SOFA BOND - based on ETAG BOND testing
Stand-off installation: e
b
= 0 mm (no stand-off); t = 10 mm
Anchor plate: l
x
x l
y
x t = 500 x 101 x 10 mm (Recommended plate thickness: not calculated)
Profile no profile
Base material: uncracked concrete , C25/30, f
cc
= 30.00 N/mm; h = 200 mm, Temp. short/long: 40/24C
Installation: hammer drilled hole, installation condition: dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
no longitudinal edge reinforcement
Geometry [mm] & Loading [kN, kNm]
1
PROFIS Anchor 2.1.4 www.hilti.at
Company: CHIRAG ALUMINUM
Specifier:
Address:
Phone I Fax: - | -
E-Mail:
Page:
Project: CANOPY
Sub-Project I Pos. No.:
Date: 9/6/2014
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2. Load case/Resulting anchor forces
Load case (Design loads):
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 19.040 0.000 0.000 0.000
2 19.040 0.000 0.000 0.000
3 19.040 0.000 0.000 0.000
4 19.040 0.000 0.000 0.000
max. concrete compressive strain []: 0.00
max. concrete compressive stress [N/mm]: 0.00
resulting tension force in (x/y)=(0/0) [kN]: 76.150
resulting compression force in (x/y)=(0/0) [kN]: 0.000
1 2
3 4
Tension
Compression
x
y
3. Tension load (EOTA TR 029, Section 5.2.2)
Proof Load [kN] Capacity [kN] Utilization b
N
[%] Status
Steel Strength* 19.038 25.333 75 OK
Combined pullout-concrete cone
failure**
76.150 79.399 96 OK
Concrete Breakout Strength** 76.150 84.237 90 OK
Splitting failure** 76.150 109.048 70 OK
* anchor having the highest loading **anchor group (anchors in tension)
Steel Strength
N
Rk,s
[kN]
38.000
g
M,s
1.500
N
Rd,s
[kN]
25.333
N
Sd
[kN]
19.038
Combined pullout-concrete cone failure
A
p,N
[mm
2
]
255700
A
p,N
0
[mm
2
]
107520
t
Rk,ucr,25
[N/mm
2
]
14.00
s
cr,Np
[mm]
328
c
cr,Np
[mm]
164
c [mm]
10000
y
c
1.018
t
Rk,ucr
[N/mm
2
]
14.26
k
3.200
y
g,Np
0
1.102
y
g,Np
1.016
e
c1,N
[mm]
0
y
ec1,Np
1.000
e
c2,N
[mm]
0
y
ec2,Np
1.000
y
s,Np
1.000
y
re,Np
1.000
N
Rk,p
0
[kN]
59.127
N
Rk,p
[kN]
142.918
g
M,p
1.800
N
Rd,p
[kN]
79.399
N
Sd
[kN]
76.150
2
PROFIS Anchor 2.1.4 www.hilti.at
Company: CHIRAG ALUMINUM
Specifier:
Address:
Phone I Fax: - | -
E-Mail:
Page:
Project: CANOPY
Sub-Project I Pos. No.:
Date: 9/6/2014
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Concrete Breakout Strength
A
c,N
[mm
2
]
258720
A
c,N
0
[mm
2
]
108900
c
cr,N
[mm]
165
s
cr,N
[mm]
330
e
c1,N
[mm]
0
y
ec1,N
1.000
e
c2,N
[mm]
0
y
ec2,N
1.000
y
s,N
1.000
y
re,N
1.000
k
1
10.100
N
Rk,c
0
[kN]
63.822
g
M,c
1.800
N
Rd,c
[kN]
84.237
N
Sd
[kN]
76.150
Splitting failure
A
c,N
[mm
2
]
206736
A
c,N
0
[mm
2
]
85264
c
cr,sp
[mm]
146
s
cr,sp
[mm]
292
y
h,sp
1.268
e
c1,N
[mm]
0
y
ec1,N
1.000
e
c2,N
[mm]
0
y
ec2,N
1.000
y
s,N
1.000
y
re,N
1.000
k
1
10.100
N
Rk,c
0
[kN]
63.822
g
M,sp
1.800
N
Rd,sp
[kN]
109.048
N
Sd
[kN]
76.150
3
PROFIS Anchor 2.1.4 www.hilti.at
Company: CHIRAG ALUMINUM
Specifier:
Address:
Phone I Fax: - | -
E-Mail:
Page:
Project: CANOPY
Sub-Project I Pos. No.:
Date: 9/6/2014
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4. Shear load (EOTA TR 029, Section 5.2.3)
Proof Load [kN] Capacity [kN] Utilization b
V
[%] Status
Steel Strength (without lever arm)* N/A N/A N/A N/A
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** N/A N/A N/A N/A
Concrete edge failure in
direction**
N/A N/A N/A N/A
* anchor having the highest loading **anchor group (relevant anchors)
5. Displacements
The displacement of the highest loaded anchor should be calculated according to the relevant approval under the effect of the following
characteristic loads.
N
Sk
= 14.100 [kN]
V
Sk
= 0.000 [kN]
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
6. Warnings
The design method SOFA assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by filling the
gap with mortar of sufficient compressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means.
The compliance with current standards (e.g. EC3) is the responsibility of the user
An SLS-check is not performed for SOFA and has to be provided by the user!
Bore hole cleaning must be performed according to instructions for use (blow 4 times with the hand pump, brush 4 times, blow again 4 times
with the hand pump).
Characteristic bond resistances depend on short- and long-term temperatures.
Checking the transfer of loads into the base material is required in accordance with EOTA TR 029, Section 7!
The anchor plate is assumed to be sufficiently stiff in order to be not deformed when subjected to the actions!
The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of EOTA TR029! For larger diameters
of the clearance hole see Chapter 1.1. of EOTA TR029!
Fastening meets the design criteria!
4
PROFIS Anchor 2.1.4 www.hilti.at
Company: CHIRAG ALUMINUM
Specifier:
Address:
Phone I Fax: - | -
E-Mail:
Page:
Project: CANOPY
Sub-Project I Pos. No.:
Date: 9/6/2014
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7. Installation data
Anchor plate, steel: -
Profile: no profile
Hole diameter in the fixture: d
f
= 14 mm
Plate thickness (input): 10 mm
Recommended plate thickness: not calculated
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.
Annular gap must be removed by e.g. filling the holes with mortar or welding the anchors to the anchor plate!
Anchor type and diameter: HIT-HY 150 MAX + HAS(-E) (5.8), M12
Installation torque: 0.040 kNm
Hole diameter in the base material: 14 mm
Hole depth in the base material: 110 mm
Minimum thickness of the base material: 140 mm
Coordinates Anchor [mm]
Anchor x y c
-x
c
+x
c
-y
c
+y
1 -200 -31 - - - -
2 200 -31 - - - -
3 -200 31 - - - -
4 200 31 - - - -
1 2
3 4
250.0 250.0
50.0 50.0
5
0
.
5
5
0
.
5
1
9
.
5
1
9
.
5
1 2
3 4
x
y
5

Potrebbero piacerti anche