The document provides technical specifications for a Stelkraft Triplex pump system. It includes details on the triplex pump such as its model, power rating, dimensions and pressure rating. It also specifies the components that make up the system including a Series 60 engine, Allison transmission, radiator assembly, control panel and Zone II explosion proofing system. The Zone II system is certified by DNV and contains temperature switches, pressure switches and an emergency shutdown system to allow safe operation in hazardous areas.
The document provides technical specifications for a Stelkraft Triplex pump system. It includes details on the triplex pump such as its model, power rating, dimensions and pressure rating. It also specifies the components that make up the system including a Series 60 engine, Allison transmission, radiator assembly, control panel and Zone II explosion proofing system. The Zone II system is certified by DNV and contains temperature switches, pressure switches and an emergency shutdown system to allow safe operation in hazardous areas.
The document provides technical specifications for a Stelkraft Triplex pump system. It includes details on the triplex pump such as its model, power rating, dimensions and pressure rating. It also specifies the components that make up the system including a Series 60 engine, Allison transmission, radiator assembly, control panel and Zone II explosion proofing system. The Zone II system is certified by DNV and contains temperature switches, pressure switches and an emergency shutdown system to allow safe operation in hazardous areas.
STELKRAFT TRIPLEX is designed to operate in Zone II Class I, Division 2, Groups A, B, C and D & it will have the following Items which comply Zone II requirement. Radiator Assembly will include standard Radiator for Jacket Water, Charge Air Cooler, Transmission Cooler & Hydraulic Oil Cooler. Control Panel will have Engine Controls, Transmission Control, Pump Rate Analyzer, Lube System Control & Process Piping Control. Displacement Tank & Suction C-Pump 4x5 are provided together with Valves. Complete Equipment is certified by DNV to operate in II Class I, Division 2 , Groups A,B,C and D. 1. TRIPLEX PUMP Model - TWS600S Type - Horizontal Triplex single acting Plunger Pump Maximum Rated Input Brake Power - 447 KW (600 BHP) Stroke - 152.4 MM (6) Max. Load, link rod - 43,360 Kg Max. Input torque - 16,320 NM Gear Ratio - 4.6 : 1 Overall Dimension - L:1,276 x W: 1,366 x H: 774 in MM Total Weight - 2086 Kg Pressure Rating - 10,000 psi
2. SERIES 60 ENGINE Model - 6063 MK74 (12.7 L) Engine Type - 4 cycle Number of Cylinders - 6 Bore x Stroke in (mm) - 5.1 in x 6.3 in (130 mm X 160 mm) Engine Control Module - DDEC IV Electronic Control System , Compliance: Class I, Division 2 , Groups A,B,C and D , T6 2 | P a g e
Engine Cooling System Min. Coolant Flow Rate in Engine Circuit - 125.1 gal/min (US) @ Peak Torque Speed (1350 r/min) - 79.2 gal/min (US) Max. Coolant out Temp. in Engine Circuit - 210 F Min. Engine Coolant Fill Rate - 3.0 gal/min (US) Min. Drawdown - 10% Max. Duration Time - 30 min Min. Top Tank Coolant Temp. - 160 F Exhaust System Max. Exhaust System Back Pressure - 3.0 in Hg Fuel System Max. Fuel Inlet Temp. - 140 F Max. Fuel Pump Suction for Clean System - 6.0 in Hg Max. Fuel Pump Suction for Dirty System - 12.1 in Hg
3. ALLISON TRANSMISSION Technical Specifications Model - 4700 OFS Rating - 600 HP Part No. - 4700 OFS Atex Group IIB, T3, Cat 3G Classified Area Input Torque Gross - 2,508 NM (1,850 ft lb) Input Power Gross Kw (hp) - 447 Kw (600 Hp) Acceptable full-load engine governed speed - 1700~2300 rpm Acceptable engine idle speed range - 500~800 rpm Standard - BS EN 13463 BS EN 60079 BS EN 50019 Test Authority - PYROBAN Specification - Certification for safe use in Group IIB, T3 , Cat 3G classified areas
Oil System Allison approved fluids - TES 295 and TES 389 Capacity excluding external circuits Without PTO - 48 Liters (51 quarts)
4. ZONE II SYSTEM (PYROBAN) Pyroban Zone II System will have the following major components. During Full Load Test of Triplex Pump, DNV surveyor will be attending the qualification of Individual Components (Temperature Switches, Pressure Switch, EMS Emergency Shutdown System, Over Speed Shut Down). MANIFOLD
Description : Inlet DDC Series 60 Standard : EN 1834-1:2000 , EEMUA Publication 107 , BP200
FLEXIBLE Description : Short 450 mm Detroit Series60 Cert No. : PYROBAN LTD Standard : EN 1834-1:2000, EEMUA Publication 107, BP200 3 | P a g e
MECHANICAL KIT DETROIT SERIES 60 SIDE MOUNTED Standard : EN 1834-1:2000 , EEMUA Publication 107 , BP200
TEMPERATURE SWITCH (1) Type - Guardian Temperature Switch Model - T1101/060HT/PB1X Process Temperature Range - 10 C to +280 C Max Working Pressure - 35 Bar Range - 175 to 225 C Trip Rising - 195 C NPT Specification - II / 3G , EEx nL Standard - EN 50021:1988
TEMPERATURE SWITCH (2) Type - Guardian Temperature Switch Model - T1101/ 038MT/ PB1X Process Temperature Range - 10 C to +175 C Max Working Pressure - 35 Bar Range - 75 to 125 C Trip Rising - 100 C NPT Specification - II / 3G, EEx nL Standard - EN 50021:1988
PRESSURE SWITCH Type - Guardian Pressure Switch Model - P1101/ B110N30/SS2X Process Temperature Range - 20 C to +150 C Max Working Pressure - 30 Bar Range - 0.1 to 1.7 BAR Trip Rising - 0.8 bar NPT Specification - II / 3G, EEx nL Standard - EN 50021:1988