Dy. DIRECTOR OF MINES SAFETY (ELEC) EASTERN ZONE
MINISTRY OF LABOUR & EMPLOYMENT
GOVERNMENT OF INDIA
SCHEME: The program of PLC is so developed that the same effects are
achieved involving minimum no. of components. The conventional items like
timers, contactors, set-reset relays etc are removed by incorporating the same in
PLC. 4 nos. of 32*24 volt DC input and 3 nos. of 32*24 volt DC output modules,
1no each of CPU and power supply modules along with 1 no back
plane( mounting plate) are used to accomplish the required task. All the
necessary preconditions are directly extended to PLC Input module without the
use of most of the contactors, timers etc which were earlier used to achieve the
same task. Depending upon the availability of input conditions, command is
issued through output module to the concerned drive/safety to function. The
preconditions available at Input module are compared with the program loaded in
CPU. In case of any deviation from the desired/safe operating condition, which
can happen due to actuation of concerned safety/operational limit switches or
tripping of concerned relays etc, concerned operation is prohibited by virtue of
blocking of relevant output command. The safety of machine is not at all
compromised and in fact additional safeties are included in some of the
applications.