AS/NZS 3823.2:2005
This Joint Australian/New Zealand Standard was prepared by Joint Technical
Committee EL-015, Quality and Performance of Household Electrical Appliances.
It was approved on behalf of the Council of Standards Australia on
8 December 2005 and on behalf of the Council of Standards New Zealand on
21 December 2005.
This Standard was published on 30 December 2005.

The following are represented on Committee EL-015:

Australian Association of Certification Bodies
Australian Consumers Association
Australian Electrical and Electronic Manufacturers Association
Australian Industry Group
Australian Retailers Association
Business New Zealand
Consumer Electronic Suppliers Association
Department of Minerals and Energy, Qld
Department of Industrial Relations, Qld
Electrical Compliance Testing Association
Energy Efficiency and Conservation Authority New Zealand
Ministry of Energy and Utilities, New South Wales
National Appliance and Equipment Energy Efficiency Committee
National Association of Testing Authorities Australia
New Zealand Manufacturers Federation
Office of the Chief Electrical Inspector, Victoria
Office of the Technical Regulator, South Australia

Additional Interests:

Air Conditioning and Refrigeration Equipment Manufacturers Association
Institute of Refrigeration Heating and Air Conditioning Engineers of
New Zealand
Institution of Professional Engineers New Zealand
Primary Industries and Resources, South Australia
Testing Interest Australia

Keeping Standards up-to-date
Standards are living documents which reflect progress in science, technology and
systems. To maintain their currency, all Standards are periodically reviewed, and
new editions are published. Between editions, amendments may be issued.
Standards may also be withdrawn. It is important that readers assure themselves
they are using a current Standard, which should include any amendments which
may have been published since the Standard was purchased.
Detailed information about joint Australian/New Zealand Standards can be found by
visiting the Standards Web Shop at www.standards.com.au or Standards New
Zealand web site at www.standards.co.nz and looking up the relevant Standard in
the on-line catalogue.
Alternatively, both organizations publish an annual printed Catalogue with full
details of all current Standards. For more frequent listings or notification of
revisions, amendments and withdrawals, Standards Australia and Standards New
Zealand offer a number of update options. For information about these services,
users should contact their respective national Standards organization.
We also welcome suggestions for improvement in our Standards, and especially
encourage readers to notify us immediately of any apparent inaccuracies or
ambiguities. Please address your comments to the Chief Executive of either
Standards Australia or Standards New Zealand at the address shown on the back
cover.

This Standard was issued in draft form for comment as DR 05316.

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6


AS/NZS 3823.2:2005
Australian/New Zealand Standard


Performance of electrical appliances
Airconditioners and heat pumps
Part 2: Energy labelling and minimum
energy performance standard (MEPS)
requirements


















COPYRIGHT
Standards Australia/Standards New Zealand
All rights are reserved. No part of this work may be reproduced or copied in any form or by
any means, electronic or mechanical, including photocopying, without the written
permission of the publisher.
Jointly published by Standards Australia, GPO Box 476, Sydney, NSW 2001 and Standards
New Zealand, Private Bag 2439, Wellington 6020

ISBN 0 7337 7077 0
Originated as AS/NZS 3823.2:1998.
Previous edition AS/NZS 3823.2:2003.
Fifth edition 2005.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 2


PREFACE
This Standard was prepared by the Joint Standards Australia/Standards New Zealand
Committee EL-15, Quality and Performance of Household Electrical Appliances, to
supersede AS/NZS 3823.2:2003 (including Amendment 1).
The AS/NZS 3823 series comprises five Parts, as follows:
AS/NZS
3823 Performance of electrical appliancesAirconditioners and heat pumps
3823.1.1 Part 1.1: Test methodsNon-ducted airconditioners and heat pumpsTesting
and rating for performance
3823.1.2 Part 1.2: Test methodsDucted airconditioners and air-to-air heat pumps
Testing and rating for performance
3823.1.3 Part 1.3 Water-source heat pumpsTesting and rating for performance:
Water-to-air and brine-to-air heat pumps
3823.2 Part 2: Energy labelling and minimum energy performance standard (MEPS)
requirements (this Standard)
3823.3 Part 3: Calculation of performance for minimum energy performance
standard (MEPS) requirements
The overall objective of the AS/NZS 3823 series of Standards is to promote high levels of
performance and energy efficiency in airconditioners and heat pumps. The Parts of the
AS/NZS 3823 series are summarized as follows:
(a) Part 1.1 includes performance test procedures for rating non-ducted airconditioners
and heat pumps, to be used in conjunction with Part 2.
(b) Part 1.2 includes performance test procedures for rating ducted airconditioners and
heat pumps, to be used in conjunction with Part 2.
(c) Part 1.3 includes performance test procedures for rating water-to-air heat pumps and
airconditioners with water cooled condensers, to be used in conjunction with Part 2.
(d) Part 2 specifies minimum energy performance standard (MEPS) requirements and
includes algorithms for the calculation of the energy efficiency star rating,
performance requirements, details of energy labels and requirements for valid
applications for registration.
(e) Part 3 specifies procedures for calculating the performance (simulation) of
airconditioners of the vapour compression type up to a rated cooling capacity of
65 kW, for minimum energy performance standard (MEPS) requirements, in lieu of
physical tests.
The main changes in this Standard are the introduction of a revised timetable and levels for
minimum energy performance standard requirements for single-phase units in the years up
to 2008 and the notification of a revised energy labelling algorithm for introduction from
2008. This edition also includes references to Part 1.3 for water sourced heat pumps.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
3 AS/NZS 3823.2:2005


Similar to the previous revisions of this Standard it is possible to use either physical tests or
simulated performance tests (described in AS/NZS 3823.3) to demonstrate compliance with
the minimum energy performance standard requirements for three-phase and some single-
phase units (units which do not carry an energy label). Only physical tests can be used to
demonstrate compliance with energy labelling. Suppliers of three-phase, single-phase
ducted and single-phase commercial units may choose to fix energy labels to products; if
so, then all of the usual requirements for energy labelling will apply (including the
requirement for a physical test). The status of energy labelling and minimum energy
performance standard (MEPS) Australian regulatory programs and their date of
implementation, for the various airconditioning equipment configurations, is provided in
Appendix E.
This Standard is published with the approval of the combined state and territory regulatory
authorities and is structured to be suitable for reference in legislation calling up minimum
energy performance standards and also for reference in energy labelling regulatory
legislation.
Key regulatory dates in this Standard and other changes are as follows:
(a) The change in scope of the mandatory energy labelling program for household
airconditioners and heat pumps from a 7.5 kW cooling requirement to a single-phase
requirement was 1 October 2001.
(b) Introduction of MEPS for three-phase airconditioners was 1 October 2001.
(c) Introduction of MEPS for single-phase airconditioners was 1 October 2004.
(d) Single-phase ducted units, which are registered to any relevant MEPS level under this
Standard, may carry an energy label on a voluntary basis.
(e) Revised three-phase MEPS levels will be introduced on 1 October 2007 (no change
from 2003 edition of this Standard).
(f) Single-phase MEPS levels for some categories of products originally proposed for
1 October 2007 have been advanced to 1 April 2006 and an additional MEPS level for
1 October 2008 has also been included.
(g) Class A efficiency levels will be valid for the next iteration of MEPS after 2008.
(h) A minor change to the wording on the energy label for variable output compressors.
Section 4 of this Standard sets out the transition provisions for energy labelling and MEPS
under this Standard.
New Zealand Energy Efficiency (Energy Using Products) Regulations 2002 had a
commencement date of 1 April 2002 for energy performance labelling of single-phase
airconditioners and 1 July 2002 for MEPS for three-phase airconditioners which currently
includes only the requirements of the 2003 edition of this Standard. The revised MEPS
levels and introductory dates for single phase units in New Zealand will be addressed by an
amendment to this Standard, which is expected in early 2006.
The terms normative and informative have been used in this Standard to define the
application of the appendix to which they apply. A normative appendix is an integral part
of a Standard, whereas an informative appendix is only for information and guidance.
Statements expressed in mandatory terms in notes to figures, are deemed to be requirements
of this Standard.


A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 4


CONTENTS
Page
SECTION 1 SCOPE AND GENERAL
1.1 SCOPE ........................................................................................................................ 6
1.2 EXCLUSIONS ............................................................................................................ 6
1.3 APPLICATION........................................................................................................... 7
1.4 OBJECTIVE................................................................................................................ 7
1.5 REFERENCED DOCUMENTS .................................................................................. 7
1.6 DEFINITIONS ............................................................................................................ 8
1.7 MEASURED QUANTITIES ..................................................................................... 10
1.8 ROUNDING.............................................................................................................. 10
1.9 CLAIMS OF CAPACITY AND ENERGY CONSUMPTION .................................. 10
SECTION 2 CALCULATIONS FOR THE ENERGY LABEL
2.1 SCOPE ...................................................................................................................... 11
2.2 GENERAL ................................................................................................................ 11
2.3 NUMBER OF TESTS AND PROCESSING OF DATA............................................ 11
2.4 COMPARATIVE ENERGY CONSUMPTION (CEC).............................................. 12
2.5 STAR RATING INDEX (SRI) .................................................................................. 12
2.6 STAR RATING......................................................................................................... 13
2.7 EXAMPLE OF ENERGY EFFICIENCY CALCULATIONS ................................... 13
2.8 ENERGY LABEL VALIDITY (CHECK TESTING) ................................................ 13
2.9 MAXIMUM COOLING TEST.................................................................................. 14
2.10 TOP ENERGY SAVER AWARD............................................................................. 14
SECTION 3 PERFORMANCE CRITERIA
3.1 GENERAL ................................................................................................................ 15
3.2 MINIMUM ENERGY PERFORMANCE STANDARD............................................ 15
3.3 CLASS A EFFICIENCY AIRCONDITIONERS....................................................... 18
3.4 TEST CONDITIONS FOR DETERMINING MINIMUM ENERGY
PERFORMANCE STANDARDS AND HIGH EFFICIENCY CLAIMS................... 19
3.5 NUMBER OF TESTS AND PROCESSING OF DATA............................................ 19
3.6 MINIMUM ENERGY PERFORMANCE STANDARD REQUIREMENTS
COMPLIANCE ......................................................................................................... 20
3.7 MEPS VALIDITY (CHECK TESTING) ................................................................... 20
3.8 VARIABLE OUTPUT COMPRESSORS.................................................................. 21
3.9 COEFFICIENT OF PERFORMANCE AT LOW TEMPERATURE......................... 21
3.10 STANDBY POWER AND CRANK CASE HEATERS ............................................ 21
3.11 LOAD CONTROL CAPABILITY ............................................................................ 21
3.12 POWER FACTOR..................................................................................................... 21
SECTION 4 APPLICATION AND TEST RESULT FORMATS
4.1 APPLICATION FOR REGISTRATION ................................................................... 22
4.2 HOLDING OF RECORDS........................................................................................ 23
4.3 DATE OF MANUFACTURE INFORMATION........................................................ 24
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
5 AS/NZS 3823.2:2005


Page
SECTION 5 PRINTING AND PLACEMENT OF ENERGY LABELS
5.1 PLACEMENT........................................................................................................... 25
5.2 MATERIAL AND SHAPE........................................................................................ 25
5.3 COLOURS ................................................................................................................ 25
5.4 LABEL REQUIREMENTS....................................................................................... 26
5.5 SAMPLE LABELS.................................................................................................... 26

APPENDICES
A EXAMPLES OF ENERGY EFFICIENCY CALCULATIONS ................................. 31
B FORMAT OF APPLICATION FOR REGISTRATION OF AN
AIRCONDITIONER FOR ENERGY LABELLING AND MEPS............................. 35
C FORMAT OF SUMMARY TEST RESULTS FOR AN ENERGY LABELLING
AND/OR MEPS APPLICATION WHERE FULL TEST REPORTS ARE NOT
PROVIDED............................................................................................................... 53
D ENERGY LABEL DIMENSIONS ............................................................................ 57
E ENERGY LABELLING AND MEPS REQUIREMENTS FOR VARIOUS
AIRCONDITIONING EQUIPMENT CONFIGURATIONS..................................... 62
F NEW ENERGY LABELLING ALGORITHMS........................................................ 66

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 6

COPYRIGHT
STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND

Australian/New Zealand Standard
Performance of electrical appliancesAirconditioners and heat pumps

Part 2: Energy labelling and minimum energy performance standard (MEPS)
requirements

S E C T I O N 1 S C O P E A N D G E N E R A L
1.1 SCOPE
This Standard specifies the energy labelling requirements for single-phase non-ducted
airconditioners of the vapour compression type for household use and the minimum energy
performance standard (MEPS) requirements for single-phase and three-phase
airconditioners of the vapour compression type up to a rated cooling capacity of 65 kW and
that fall within the scope of AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3.
Particular regulatory requirements for different categories of airconditioning equipment and
validity dates are summarized in Appendix E of this Standard.
The revised MEPS levels and introductory dates for single phase units beyond 2004 in New
Zealand will be addressed by an amendment to this Standard.
This Standard does not specify electrical safety requirements.
This Standard specifies the following values for cooling and heating, as applicable:
(a) Rated power (input).
(b) Rated capacity (output).
(c) Energy efficiency ratio (EER) for cooling.
(d) Coefficient of performance (COP) for heating.
(e) Comparative energy consumption (CEC).
(f) Star Rating Index (SRI).
(g) Star rating.
(h) Some of the requirements for energy label validity.
(i) The performance criteria for energy labelling validity.
(j) Test report format.
(k) Printing requirements for airconditioner appliance energy labels.
(l) Minimum energy performance standard requirements.
1.2 EXCLUSIONS
The following equipment is excluded from the scope of this Standard:
(a) Close controlled airconditioners, pending the development of MEPS levels for these
products.
(b) Multi-split systems (i.e., those having more than one indoor unit with an independent
control for each indoor unit) pending the development of a suitable test method.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
7 AS/NZS 3823.2:2005

COPYRIGHT
(c) Evaporative coolers or any other cooling systems that are not of the vapour
compression type.
(d) Ground-water-sourced or ground-loop-sourced heat pumps within the scope of
Part 1.3.
NOTE: Water loop heat pumps as defined in Part 1.3 are included within the scope of this
Standard.
(e) Unbalanced airconditioners and spot coolers (these include many portable types).
(f) Commercial chillers which are used in commercial buildings to provide chilled-water
for space cooling equipment.
(g) Models that have been granted exemption by the relevant Australian/New Zealand
regulatory authority due to their specific design for applications such as process
heating or cooling or for heating or cooling of spaces to conditions that are not
intended for human comfort.
1.3 APPLICATION
This Standard shall be read in conjunction with AS/NZS 3823.1.1, AS/NZS 3823.1.2,
AS/NZS 3823.1.3 and AS/NZS 3823.3, as applicable.
Products that have water-cooled condensers as well as water-source heat pumps fall within
the scope of this Standard and shall meet the relevant labelling and/or MEPS requirements
for the cooling function. For these products, the cooling and heating performance shall be
determined and declared in accordance with AS/NZS 3823.1.3. Cooling only products with
water-cooled condensers that are included within the scope of AS/NZS 3823.1.1 and
AS/NZS 3823.1.2 shall be tested to AS/NZS 3823.1.3 wherever possible.
1.4 OBJECTIVE
The objective of this Standard is to
(a) provide detailed information on the performance and energy labelling requirements
which an airconditioning appliance has to meet in order to carry a valid energy
efficiency label;
(b) provide detailed information on the performance requirements which an
airconditioning appliance has to meet in order meet minimum energy performance
standard requirements; and
(c) describe the circumstances in which alternatives to physical testing may be used to
demonstrate and verify compliance with minimum energy performance standard
requirements.
1.5 REFERENCED DOCUMENTS
The following documents are referred to in this Standard:
AS
2706 Numerical valuesRounding and interpretation of limiting values
2834 Computer accommodation
AS/NZS
3823 Performance of household electrical appliancesAirconditioners and heat
pumps
3823.1.1 Part 1.1: Test methodsNon-ducted airconditioners and heat pumpsTesting
and rating for performance
3823.1.2 Part 1.2: Test methodsDucted airconditioners and air-to-air heat pumps
Testing and rating for performance
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 8

COPYRIGHT
3823.1.3 Part 1.3: Water-source heat pumpsTesting and rating for performance:
Water-to-air and brine-to-air heat pumps
3823.3 Part 3: Calculation of performance for minimum energy performance
standard (MEPS) requirements
1.6 DEFINITIONS
For the purposes of this Standard the definitions given in AS/NZS 3823.1.1,
AS/NZS 3823.1.2, AS/NZS 3823.1.3 and those below apply.
1.6.1 Check test
A full or part test in accordance with AS/NZS 3823.1.1, AS/NZS 3823.1.2,
AS/NZS 3823.1.3 or AS/NZS 3823.3, as applicable, to verify the performance or energy
consumption, or both, of an individual model.
1.6.2 Class A efficiency
Rating for an airconditioner that meets the minimum EER cooling values specified in
Clause 3.3.
1.6.3 Close controlled airconditioners
An airconditioner that meets the requirements of AS 2834 for Environment Type 1
conditions and satisfies the requirements of the process carried out in the airconditioned
room.
1.6.4 Comparative energy consumption (CEC)
The nominal energy consumption of a model of airconditioner. It is the estimate of energy
used by a single unit per hour of use at rated power for cooling and/or heating, as
applicable. It assumes the unit operates under standard conditions (as defined in
AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3) (see also Clause 2.3). The
CEC appears on the energy label as Power input. (Units: kW.)
1.6.5 Ducted airconditioners
An airconditioner model configuration where the indoor side is situated remote to the space
to be conditioned. The conditioned air is supplied or extracted via a duct.
1.6.6 Family of models
A range of models of the one brand, for which a single set of test reports is applicable and
where each of the models has the same relevant physical characteristics, comparative
energy consumption, energy efficiency rating, performance characteristics and refrigerant.
The term model is synonymous with family of models.
NOTE: A product that has single-phase and three-phase variants will have to be separately
registered and cannot be considered as one family (as MEPS requirements for single- and three-
phase variants may be different). Single- and three-phase products may be separately registered
using a single test report that covers these variants, as long as the product tested has the lowest
EER and COP of all the relevant variants.
1.6.7 Multi-split system
A split system airconditioner with a refrigeration system having a single outdoor unit and
two or more indoor units, each indoor unit being independently controlled.
1.6.8 Non-ducted airconditioner
An airconditioner model configuration where the indoor side is situated partly or wholly
within the space to be conditioned. The conditioned air is supplied and extracted directly to
and from the conditioned space.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
9 AS/NZS 3823.2:2005

COPYRIGHT
1.6.9 Rated capacity
The nominal rated capacity claimed by the manufacturer of an airconditioner model
determined as follows, as applicable:
(a) Rated total cooling capacity As claimed by the manufacturer in accordance with
AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3 for temperature
condition T1. (Units: W or kW.)
(b) Rated heating capacity As claimed by the manufacturer in accordance with
AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3 for temperature
condition H1. (Units: W or kW.)
The rated capacity appears on the energy label as Capacity Output (heating and/or cooling
as applicable. (Units: kW).
For variable output capacity equipment, the rated capacity of each model shall not exceed
the maximum continuous output rating possible by the unit. Short term peak outputs shall
not be used for rated capacity.
1.6.10 Rated power
Effective power input of the airconditioner model as claimed by the manufacturer in
accordance with AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3 during the
determination of rated cooling capacity and rated heating capacity, as applicable. (Units: W
or kW.)
1.6.11 Split system
An airconditioner with separate indoor and outdoor components that are connected with
refrigerant piping. The indoor unit usually lies within the conditioned space and may be
installed or portable/mobile.
NOTE: The indoor unit in some configurations may feed into a duct system. Some split ducted
system indoor units may have no fan and are designed to operate with an existing system (e.g.,
gas heater).
1.6.12 Spot cooler
A unitary airconditioner that lies wholly within a conditioned space and that draws air for
both the evaporator and condenser from the conditioned space and expels both of these back
into the conditioned space.
1.6.13 Star rating
The number of stars displayed on the energy label. Available stars are between a minimum
of one and a maximum of six, shown in half star intervals. The star rating is calculated from
the Star Rating Index (see Clause 2.6). (Dimensionless.)
1.6.14 Star rating index (SRI)
An indication of the claimed energy efficiency of a model at rated conditions. A higher SRI
indicates a higher energy efficiency. It is derived from the measured EER or measured
COP, as applicable (see Clause 2.5).
1.6.15 Statements of intention
1.6.15.1 Shall
Indicates that a statement is mandatory.
1.6.15.2 Should
Indicates a recommendation.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 10

COPYRIGHT
1.6.16 Three-phase model
A model where at least one component in the airconditioning system requires an external
three-phase power supply.
1.6.17 Single-phase model
A model where all components in the airconditioning system that require an external power
supply require only single-phase power.
NOTE: Some components of an airconditioner system may be supplied a.c. or d.c. power via
internal wiring.
1.6.18 Twin (or triple) split
A split system airconditioner comprising a single outdoor unit with two (or three) indoor
units that are controlled by a single controller.
1.6.19 Unbalanced airconditioner
An unbalanced airconditioner is a unitary airconditioner that lies wholly within a
conditioned space and that draws air from the conditioned space and expels this to outdoors.
An unbalanced airconditioner is usually ducted (where the exhaust air from the heat
exchanger is expelled from the conditioned space via a flexible duct, pipe or opening) but
may be connected to a pipe or other opening such as a window. These units are typically
portable or mobile.
1.6.20 Unitary airconditioner
An airconditioner where the evaporator, condenser and associated refrigeration components
(e.g., compressor) are contained within a single casing. Unitary airconditioners may be non-
ducted (e.g., window/wall units) or ducted (e.g., single packaged units).
1.7 MEASURED QUANTITIES
Quantities used in this Standard shall be measured during tests carried out in accordance
with AS/NZS 3823.1.1, AS/NZS 3823.1.2, AS/NZS 3823.1.3 or AS/NZS 3823.3, as
applicable.
1.8 ROUNDING
Unless otherwise stated, numbers shall be rounded and recorded to five significant figures
in accordance with AS 2706.
1.9 CLAIMS OF CAPACITY AND ENERGY CONSUMPTION
Any unqualified claims of capacity and energy consumption shall be rated values for
condition T1 or H1, as applicable (see Clauses 1.6.9 and 1.6.10). Other claims of capacity
and energy consumption shall be qualified by the conditions under which these values are
determined. The use of 'horsepower' as a unit of measure for air conditioner output capacity
shall not be used because it does not directly correlate to the output capacity in kW and is
therefore misleading.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
11 AS/NZS 3823.2:2005

COPYRIGHT
S E C T I O N 2 C A L C U L A T I O N S F O R T H E
E N E R G Y L A B E L
2.1 SCOPE
This Section sets out the equations and procedures for calculating the CEC, SRI values and
the star rating, which appear on an energy label. This Section applies to all single-phase
non-ducted appliances that fall within the Scope of this Standard, and to three-phase
appliances and ducted single-phase appliances which the supplier elects to register or have
records kept for energy labelling.
2.2 GENERAL
Energy labels may not be fixed to appliances that do not comply with the requirements of
this Section. Energy labels are provided for cooling only units, heating only units and
heating and cooling units. Units that have the capability to both heat and cool shall be
labelled as a heating and cooling unit, except where the heating is provided only by means
of resistive heating, in which case it shall be labelled as cooling only (refer to Clause 5.3.4).
The capacity and energy values shown on the energy label are based on the rated capacity
and the rated power, as claimed by the manufacturer. The values on the energy label shall
be consistent with the capacity on the models rating nameplate or all other data in any
associated product literature (or both) for the specified conditions. The Star Rating Index of
the airconditioner shall be based on the tested average energy efficiency ratio (EER), and
the tested average coefficient of performance (COP), as applicable, for the unit(s) tested.
The results of the unit(s) tested are used to assess the validity of the rated capacity and the
rated power. The determination of tested capacity (cooling and heating) and tested total
power input for the unit(s) used for the purposes of energy labelling shall be conducted
using the calorimeter test method as specified in AS/NZS 3823.1.1 or AS/NZS 3823.1.2 for
condition T1 for cooling or condition H1 for heating, as applicable, or AS/NZS 3823.1.3
Table 1 for cooling and Table 2 for heating. Determinations using the outdoor air-
enthalpy/psychrometric test method of these Standards or determinations using the
simulation method specified in AS/NZS 3823 are not acceptable.
2.3 NUMBER OF TESTS AND PROCESSING OF DATA
2.3.1 Number of units required
For the purposes of verification of the rated values of a model at least one unit of the
nominated model shall be tested for capacity, effective power input and EER on cooling or
heating and, where applicable, capacity, effective power input and COP on heating in
accordance with AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3. At the
suppliers discretion more than one unit may be tested.
2.3.2 Number of tests per unit
Only one valid test from each unit tested shall be considered when determining the energy
label data in accordance with AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3.
2.3.3 Verification of rated values
As a prerequisite to the determination of values for an energy label, the unit(s) tested shall
each comply with the following validity criteria for cooling and heating, as applicable:
(a) Tested effective power input for each unit .................................. 1.05 rated power.
(b) Tested cooling and heating capacity for each unit .................... 0.95 rated capacity.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 12

COPYRIGHT
2.4 COMPARATIVE ENERGY CONSUMPTION (CEC)
The CEC of an airconditioner model is calculated by the following equation:
) (kW power rated CEC = . . . 2.4
CEC is in kW rounded to the nearest 0.01. Rated power is in kilowatts.
The CEC is determined for cooling and heating, as applicable.
2.5 STAR RATING INDEX (SRI)
2.5.1 General
The equations for SRI in the following clauses are derived from a market analysis in 1998
and were introduced in 2000. The revised equations to be introduced in 2008 reflect
improvements in airconditioner efficiency achieved since the introduction of Energy
Labelling. These are documented in Appendix F. The original air conditioner equations
were introduced in 1987.
The SRI for a model of airconditioner for cooling and heating, as applicable, shall be
determined in accordance with Clauses 2.5.2 and 2.5.3 respectively, using the measured
average values of EER and COP for the unit(s) tested, as applicable. The SRI shall also be
calculated and reported for appliances registered only for compliance with minimum energy
performance standard requirements. The value for EER and COP shall be in Watts/Watt.
2.5.2 SRI cooling
The SRI for cooling is calculated by the following equation:
[ ] 3 / 17 ) 10 EER average Tested ( cooling SRI = . . . 2.5(1)
2.5.3 SRI heating
The SRI for heating is calculated by the following equation:
[ ] 3 / 20 ) 10 COP average Tested ( heating SRI = . . . 2.5(2)
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
13 AS/NZS 3823.2:2005

COPYRIGHT
2.6 STAR RATING
The star rating is based on the SRI and is obtained from Table 2.1.
TABLE 2.1
DERIVATION OF STAR RATING
Star Rating Index
(SRI)
Star rating
SRI <1.5 1.0
1.5 SRI < 2.0 1.5
2.0 SRI < 2.5 2.0
2.5 SRI < 3.0 2.5
3.0 SRI < 3.5 3.0
3.5 SRI < 4.0 3.5
4.0 SRI < 4.5 4.0
4.5 SRI < 5.0 4.5
5.0 SRI < 5.5 5.0
5.5 SRI < 6.0 5.5
6.0 SRI 6.0
2.7 EXAMPLE OF ENERGY EFFICIENCY CALCULATIONS
NOTE: For a complete example of calculations carried out on a typical set of test results refer to
Appendix A.
2.8 ENERGY LABEL VALIDITY (CHECK TESTING)
The energy label shall be accepted as valid when a single sample of a model, tested for an
initial screening test, meets the following criteria for cooling and heating, as applicable:
(a) Tested effective power input ...................................................... 1.10 rated power.
(b) Tested cooling and heating capacity ........................................ 0.90 rated capacity.
(c) Tested EER .................................................................................. 0.90 rated EER.
(d) Tested COP..................................................................................0.90 rated COP.
If the above criteria do not apply, the label shall be accepted as valid if up to three
additional units are tested and the average values for these additional units are as follows:
(i) Tested average effective power input ......................................... 1.10 rated power.
(ii) Tested average cooling and heating capacity ........................... 0.90 rated capacity.
(iii) Tested average EER...................................................................... 0.90 rated EER.
(iv) Tested average COP .....................................................................0.90 rated COP.
NOTE: More details on check testing and validity criteria can be found in the Administrative
Guidelines. The most up to date version can be obtained from www.energyrating.gov.au website.
Check testing will be undertaken using the conditions (e.g. settings, duct pressure and air
flow rates) specified in the application for registration for MEPS and energy labelling
(where applicable).
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 14

COPYRIGHT
2.9 MAXIMUM COOLING TEST
Appliances that carry an energy label shall meet the requirements of the maximum cooling
test set out in AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3, as applicable,
when tested to temperature condition T1 as specified for the maximum cooling test. This
test may be conducted using either a calorimeter or the outdoor air-enthalpy/psychrometric
test method.
While all units within a model are required to meet the maximum cooling tests requirements
of AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3, only one unit need be tested
to confirm this for the purposes of energy labelling and MEPS. Evidence of such a test
report should be provided on registration.
2.10 TOP ENERGY SAVER AWARD
The Top Energy Saver Award Winner (TESAW) is an award system that Governments have
created to recognize the most efficient products on the market. Products, which have
qualified for an award may display the text for the relevant award year on the energy label
as specified in Section 5.
NOTE: Background, criteria, and the method of applying for The Top Energy Saver Award
Winner is given on www.energyrating.gov.au website.

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
15 AS/NZS 3823.2:2005

COPYRIGHT
S E C T I O N 3 P E R F O R M A N C E C R I T E R I A
3.1 GENERAL
The performance criteria set out in Clauses 3.2 to 3.7 shall be met by all units.
NOTE: Where a system has more than one power supply (e.g., a split system), the whole system
is considered to be three-phase for the purposes of this Standard where at least one of the external
power supply systems is three-phase. See Clause 1.6.16 for a definition of a three-phase model.
3.2 MINIMUM ENERGY PERFORMANCE STANDARD
For airconditioners manufactured in Australia or New Zealand or imported after the dates
specified, the EER cooling shall be greater than or equal to the minimum limits given in
Table 3.1 or Table 3.2, as applicable. For the purposes of determining the relevant MEPS
level in Table 3.1 or Table 3.2, rated capacity shall be rounded to the nearest 0.1 kW.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 16

COPYRIGHT
TABLE 3.1
MINIMUM ENERGY PERFORMANCE STANDARDS (MEPS)
MINIMUM REQUIREMENTS FOR AIR COOLED CONDENSER AIR
CONDITIONERS
Configuration Cooling
only or
reverse
cycle
Phase Rated
cooling
capacity
(kW)
Min
EER
1-Oct-
2001
Min
EER
1-Oct-
2004
Min
EER
1-Apr-
2006
Min
EER
1-Oct-
2007
Min
EER
1-Oct-
2008
C/O 1 <7.5 n/a 2.45 2.75
b
2.75 2.84
d

C/O 1 7.5 to <10 n/a 2.45 2.45 2.75 2.84
d

C/O 1 10.0 to 18.9
a
n/a 2.45 2.45 2.75 2.75
R/C 1 <7.5 n/a 2.30 2.75
b
2.75 2.84
d

R/C 1 7.5 to <10 n/a 2.30 2.30 2.75 2.84
d

R/C 1 10.0 to 18.9
a
n/a 2.30 2.30 2.75 2.75
Both 3 <10 2.25 2.25 2.25 2.75 2.84
d

Both 3 10 to 12.5 2.30 2.30 2.30 2.75 2.75
Both 3 12.6 to 15.5 2.35 2.35 2.35 2.75 2.75
Both 3 15.6 to 18 2.40 2.40 2.40 2.75 2.75
Non ducted
unitary
(window/wall)
Both 3 18.1 to 18.9
c
2.45 2.45 2.45 2.75 2.75
C/O 1 <4 n/a 2.45 3.05
b
3.05 3.33
d

C/O 1 4 to <7.5 n/a 2.45 2.75
b
2.75 2.93
d

C/O 1 7.5<10 n/a 2.45 2.45 2.75 2.93
d

C/O 1 10.0 to 18.9
a
n/a 2.45 2.45 2.75 2.75
R/C 1 <4 n/a 2.30 3.05
b
3.05 3.33
d

R/C 1 4 to <7.5 n/a 2.30 2.75
b
2.75 2.93
d

R/C 1 7.5 to <10 n/a 2.30 2.30 2.75 2.93
d

R/C 1 10.0 to 18.9
a
n/a 2.30 2.30 2.75 2.75
Both 3 <4 2.25 2.25 2.25 3.05 3.33
d

Both 3 4 to <7.5 2.25 2.25 2.25 2.75 2.93
d

Both 3 7.5 <10 2.25 2.25 2.25 2.75 2.93
d

Both 3 10 12.5 2.30 2.30 2.30 2.75 2.75
Both 3 12.6 15.5 2.35 2.35 2.35 2.75 2.75
Both 3 15.6 18 2.40 2.40 2.40 2.75 2.75
Both 3 18.1 18.9 2.45 2.45 2.45 2.75 2.75
Both 3 19 25 2.45 2.45 2.45 3.05 3.05
Both 3 25.1 30 2.50 2.50 2.50 3.05 3.05
Both 3 30.1 37.5 2.55 2.55 2.55 3.05 3.05
Both 3 37.6 39 2.60 2.60 2.60 3.05 3.05
Both 3 39.1 45.5 2.60 2.60 2.60 2.75 2.75
Non ducted split
Both 3 45.6 65 2.65 2.65 2.65 2.75 2.75
(continued)
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
17 AS/NZS 3823.2:2005

COPYRIGHT
C/O 1 0 <10 n/a 2.45 2.45 2.50 2.50
C/O 1 10 18.9
a
n/a 2.45 2.45 2.50 2.75
R/C 1 0 <10 n/a 2.30 2.30 2.50 2.50
R/C 1 10 18.9
a
n/a 2.30 2.30 2.50 2.75
Both 3 0 <10 2.25 2.25 2.25 2.50 2.50
Both 3 10 12.5 2.30 2.30 2.30 2.75 2.75
Both 3 12.6 15.5 2.35 2.35 2.35 2.75 2.75
Both 3 15.6 18 2.40 2.40 2.40 2.75 2.75
Both 3 18.1 18.9 2.45 2.45 2.45 2.75 2.75
Both 3 19 25 2.45 2.45 2.45 3.05 3.05
Both 3 25.1 30 2.50 2.50 2.50 3.05 3.05
Both 3 30.1 37.5 2.55 2.55 2.55 3.05 3.05
Both 3 37.6 39 2.60 2.60 2.60 3.05 3.05
Both 3 39.1 45.5 2.60 2.60 2.60 2.75 2.75
Ducted (split &
unitary)
Both 3 45.6 65 2.65 2.65 2.65 2.75 2.75
NOTES:
1 AS/NZS 3823.2 defines terms and applicable dates used in this table.
aFor single phase product over 18.9 kW cooling capacity, the relevant 3 phase MEPS level for the
rated cooling capacity is applicable from October 2008.
bIncreased MEPS levels for 1 April 2006 apply to any product marketed for household use. Products which are
purely commercial are subjected to the 2006 MEPS levels indicated from 1 October 2007. MEPS for 2007 and 2008
apply to all product types irrespective of use.
cFor three phase non-ducted unitary products > 18.9 kW, MEPS are the same as for non-ducted-split systems.
dThese MEPS levels are subject to confirmation by an amendment to this Standard during 2006.
2 Not applicable is indicated by n/ano coverage of this product type from the date specified.
3 The revised MEPS levels and introductory dates for levels beyond 2004 in New Zealand will be addressed by an
amendment to this Standard.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 18

COPYRIGHT

TABLE 3.2
MEPSMINIMUM EER FOR WATER COOLED CONDENSER
AIRCONDITIONERS
(see Note 1)
Supply
(No. of
phases)
Cooling capacity/Type
1 Oct. 2001
(see Note 2)
1 Oct. 2004 1 Oct. 2007
All capacitiesCooling only (ducted and
non-ducted)
N/A 2.45 3.50
1
All capacitiesReverse cycle (ducted and
non-ducted)
N/A 2.30 3.50
< 10 kW 2.25 2.25 3.50
1012.5 kW 2.30 2.30 3.50
12.615.5 kW 2.35 2.35 3.50
15.618.0 kW 2.40 2.40 3.50
18.118.9 kW 2.45 2.45 3.50
19.025.0 kW 2.45 2.45 3.50
25.130.0 kW 2.50 2.50 3.50
30.137.5 kW 2.55 2.55 3.50
37.639.0 kW 2.60 2.60 3.50
39.045.5 kW 2.60 2.60 3.20
3
45.665.0 kW 2.65 2.65 3.20
NOTES:
1 This table includes requirements for airconditioners with water cooled condensers and water sourced
heat pumps.
2 In New Zealand, MEPS became mandatory on 1 July 2002.
3 The revised MEPS levels and introductory dates for levels beyond 2004 in New Zealand will be
addressed by an amendment to this Standard.
3.3 CLASS A EFFICIENCY AIRCONDITIONERS
The EER cooling for an airconditioner that claims to be Class A efficiency shall be greater
than or equal to the minimum limits given in Table 3.3.
TABLE 3.3
FUTURE MEPS LEVELS BEYOND 2008
(CLASS A EFFICIENCY)
MINIMUM EER COOLING
AIRCONDITIONERS WITH AIR COOLED CONDENSERS
Rated cooling capacity
(kW)
Minimum EER cooling
(W/W)
kW 10.0 Under consideration
10.0 < kW 19.0 3.35
19.0 < kW 39.0 3.65
kW > 39.0 3.35
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
19 AS/NZS 3823.2:2005

COPYRIGHT
3.4 TEST CONDITIONS FOR DETERMINING MINIMUM ENERGY
PERFORMANCE STANDARDS AND HIGH EFFICIENCY CLAIMS
The unit shall be operated at rated capacity under the cooling capacity test with
CONDITION T1 in accordance with AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or
AS/NZS 3823.1.3 for the determination of cooling capacity, effective power input, energy
efficiency ratio and compliance with minimum EER cooling requirements.
Appliances with variable output compressors, which do not meet the minimum energy
performance standard requirements at rated capacity under CONDITION T1 in
AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3, may be tested at part load
operation. Variable output compressors shall be deemed to comply with the minimum EER
cooling requirements of this standard if they achieve the minimum required EER when they
are operated at not less than 50% of their rated cooling capacity, under CONDITION T1. A
separate test report with supporting data is required if compliance with MEPS is not at
100% of rated capacity.
3.5 NUMBER OF TESTS AND PROCESSING OF DATA
For the purposes of demonstrating compliance with minimum energy performance standard
requirements a report shall be prepared as follows:
(a) For units registered for energy labelling (on either a mandatory or voluntary basis)
and MEPS: one physical test conducted in accordance with AS/NZS 3823.1.1 or
AS/NZS 3823.1.2 for CONDITION T1 for cooling and CONDITION H1 for heating,
or one physical test conducted in accordance with AS/NZS 3823.1.3 to Table 1 for
cooling and Table 2 for heating, as applicable:
or
(b) For units registered for MEPS only: either a simulation of performance as specified in
AS/NZS 3823.3, or one physical test conducted in accordance with ASNZS 3823.1.1
or AS/NZS 3823.1.2 for CONDITION T1 for cooling and CONDITION H1 for
heating, or one physical test conducted in accordance with AS/NZS 3823.1.3 to Table
1 for cooling and Table 2 for heating, as applicable.
Where appliances are of a configuration not within the scope of AS/NZS 3823.3 (e.g.,
where technology that cannot be accurately modelled is used, such as unitary systems where
there is thermal interaction between internal components, water cooled units, non steady
state behaviour such as defrosting) there is no alternative to a physical test.
The applicability of energy labelling and MEPS program elements together with relevant
application dates shall be in accordance with the provisions of Appendix E.
As a prerequisite to the verification of MEPS compliance, any physical test result used to
support an application for MEPS shall meet the validity criteria for cooling as set out in
Clause 2.3.3. For product registered using simulation to AS/NZS 3823.3, the rated capacity
shall not exceed the capacity obtained by simulation.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 20

COPYRIGHT
3.6 MINIMUM ENERGY PERFORMANCE STANDARD REQUIREMENTS
COMPLIANCE
Evidence of minimum energy performance standard requirements compliance can be
provided by a report on a physical test to AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or
AS/NZS 3823.1.3 requirements or for certain product types a report on a simulation test to
AS/NZS 3823.3 requirements as specified in Clause 3.5. The report shall demonstrate that
each appliance meets or exceeds the minimum EER cooling requirement for the appliance
capacity. The claimed capacity and power consumption for both cooling and heating, if
applicable, shall be substantiated by physical testing or simulation of appliance
performance for the standard rating conditions set out in Clause 3.5.
NOTE: An example of airconditioner assessment for MEPS is provided in Appendix A.
3.7 MEPS VALIDITY (CHECK TESTING)
Check testing of a product may be either by a physical test or a simulation test. In the case
of dispute, test results obtained by physical testing, using the procedures defined in
AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3, take precedence over test
results obtained using a simulation model. In the case of a physical test, check testing will
be undertaken using the calorimeter method wherever possible as this provides a more
reliable result for verification purposes.
Generally a screening test is conducted on a single model and if this fails any of the criteria
below, up to 3 additional units are tested in Stage 2. The rated data shall be accepted as
valid if the product satisfies the EER requirement and data from the verification test meets
all of the following criteria.
(a) Tested effective power input ...................................................... 1.10 rated power.
(b) Tested cooling and heating capacity ........................................ 0.90 rated capacity.
(c) Tested EER .......................................................MEPS limit and 0.90 rated EER.
(d) Tested COP..................................................................................0.90 rated COP.
NOTES:
1 Simulation models provide an estimate of system optimum performance under idealized
operating conditions. Modelling may not take into account variables introduced in the
physical manufacture of a system, such as airflow across the coils. For this reason actual tests
may show a performance lower than that estimated by the simulation model. Physical tests
take priority in this Standard and performance claims based on a simulation model are made
at the applicants own risk.
2 More details on check testing and validity criteria can be found in the Administrative
Guidelines. The most up to date version can be obtained from the www.energyrating.gov.au
website.
Where a physical check test is undertaken to validate a registration, the laboratory should
provide all relevant physical measurements (such as pressure drops and refrigerant
temperatures etc.) that will allow the physical check test to be fully compared with the
original test report or the simulation result (refer to Appendix C).
Check testing will be undertaken using the conditions (e.g. settings, duct pressure and air
flow rates) specified in the application for registration for MEPS and energy labelling
(where applicable).
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
21 AS/NZS 3823.2:2005

COPYRIGHT
3.8 VARIABLE OUTPUT COMPRESSORS
Products that have variable output compressors (e.g., multi-speed or inverter-driven or
variable speed compressors) have this indicated on the www.energyrating.gov.au website
and on the energy label (where applicable). These products may also claim EER and COP
figures (as applicable) at 50% of the rated capacity for CONDITIONS TI and HI in
AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3 (as applicable) for display on
the www.energyrating.gov.au website. Performance data shall be displayed on the website
only when the claim is supported by test data at the time of registration or listing.
NOTE: Such products can have a high relative efficiency at part load. If these products are
identified to the relevant regulatory authority and supporting test data is provided, the part load
performance figures will be displayed on the www.energyrating.gov.au website. Generally, an
output in the range of 50% to 60% is acceptable for this listing.
3.9 COEFFICIENT OF PERFORMANCE AT LOW TEMPERATURE
NOTE: Minimum coefficient of performance of heat pumps at low ambient temperature is under
consideration by regulatory authorities.
3.10 STANDBY POWER AND CRANK CASE HEATERS
All products shall have the following data measured for the model as set out in
AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3 (as applicable):
(a) Off mode power consumption (Watts).
(b) Passive standby mode power consumption, where applicable (Watts).
(c) Whether or not the product has any form of crank case heating.
(d) Where a crank case heater is present, the average crank case heater power
consumption under outdoor conditions specified in the relevant standards for all
airconditioner types (i.e., whether cooling only, heating only or reverse cycle).
During registration or listing, the above data shall be provided as set out in Appendix C.
Relevant data will be displayed on the www.energyrating.gov.au website.
3.11 LOAD CONTROL CAPABILITY
Planning is under way to mandate facilities for external load control and communications
capability for certain airconditioner types within the scope of this standard. These will be
included in a future amendment to this Standard.
3.12 POWER FACTOR
The average power factor during cooling and heating capacity rating tests shall be reported
for all products.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 22

COPYRIGHT
S E C T I O N 4 A P P L I C A T I O N A N D T E S T
R E S U L T F O R M A T S
4.1 APPLICATION FOR REGISTRATION
4.1.1 General
Where the relevant regulatory authority requires registration or approval of energy labels or
minimum energy performance standard requirements, Clauses 4.1.2 and 4.1.6 shall apply.
NOTE: Australia requires registration for energy labelling and MEPS. Three-phase heating only
models do not require registration for MEPS; however, data to support claimed performance are
still required under Clause 4.2.
4.1.2 Registration
For an energy labelling and MEPS application in accordance with Appendix B, a test report
to AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3 or a summary report in
accordance with Appendix C shall be provided. For a MEPS application in accordance with
Appendix B, a test report to AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3 or
a summary report in accordance with Appendix C shall be provided where physical tests
have been conducted. Where a simulation to AS/NZS 3823.3 has been conducted for a
MEPS application in accordance with Appendix B, a report in accordance with
Appendices A and B of AS/NZS 3823.3 shall be provided.
NOTES:
1 Applications in the form of computer printouts, which present all the application data in a
similar layout to the forms in Appendix B, are equally valid.
2 Where HPRATE has been used for a simulation to support a MEPS application, a copy of the
project (sys) file is regarded as equivalent to a report in accordance with Appendices A and B
of AS/NZS 3823.3. Where values other than the defaults for pressure drop, subcooling or
superheating are used in the project file (see Appendix A), test data to support the use of
these values will be required.
For registration, the relevant state regulatory authority shall be contacted.
NOTE: Details of the relevant regulatory bodies are available from www.energyrating.gov.au
website.
4.1.3 Test report
A test report in accordance with AS/NZS 3823.1.1, AS/NZS 3823.1.2, AS/NZS 3823.1.3 or
AS/NZS 3823.3, as applicable, for each model tested shall be held by the appliance supplier
if not supplied with the original registration.
The documents required by this Section shall be made available to the relevant regulatory
authority upon request. Records shall be retained for at least five years after the last date of
manufacture or import, whichever is applicable.
4.1.4 MEPS transition
All products within the scope of MEPS manufactured or imported for sale in Australia on or
after the relevant MEPS date shall meet the relevant MEPS requirements. Such units shall
hold a valid registration at the time of sale, which shall indicate compliance with these
MEPS requirements.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
23 AS/NZS 3823.2:2005

COPYRIGHT
Single phase non-ducted household products <7.5kW cooling which are registered as
complying with October 2007 MEPS requirements under the 2003 edition of this Standard
will be deemed to comply with the April 2006 MEPS requirements of this Standard when
registration expiry dates are reviewed by regulators. Registrations which have not indicated
compliance with the April 2006 MEPS requirements of this Standard will expire on
31 March 2006.
Registrations to the 2003 edition of this Standard will be permitted up to 31 March 2006.
All registrations after this date shall be in accordance with this Standard.
NOTE: More details on the duration and validity of registrations can be found in the
Administrative Guidelines. The most up to date version can be obtained from the
www.energyrating.gov.au website.
4.1.5 Energy label transitions
Regulators have advised that products with existing registrations for energy labelling to a
previous edition of this Standard can continue to affix and display these previously
approved labels until the product requires re-registration for MEPS or energy labelling as
defined in this Standard.
Products with energy labels to previous editions of this Standard which are manufactured or
imported prior to the relevant MEPS implementation date may be supplied directly from a
warehouse without the need to re-label for an indefinite period.
NOTE: Energy labelling algorithms are due to change in 2008 (refer Appendix F) and all products
will require re-registration and new labels as defined in a future edition of this Standard from that
date. Special provisions will apply to products on display in retailers during the 2008 energy
transition.
4.1.6 Duration of registration
Registrations for energy labelling and MEPS may have a validity of up to 5 years.
Registration expiry dates are reviewed annually and records may be extended (up to the 5
year limit in 1 year increments) where there is no forthcoming change to regulatory
requirements.
Registrations of single phase products to previous editions of this Standard will expire no
later than 30 September 2008.
NOTE: More details on the duration of registration can be found in the Administrative
Guidelines. The most up to date version can be obtained from the www.energyrating.gov.au
website.
4.2 HOLDING OF RECORDS
4.2.1 General
Where the registration or approval of energy labels or minimum energy performance
standard requirements is not required, Clauses 4.2.2 and 4.2.3 shall apply.
NOTE: This Clause is applicable to New Zealand.
4.2.2 Data
Appendix B gives the information that shall be reported and held by the appliance supplier
(manufacturer or importer), to support the performance claims.
4.2.3 Test report
A test report in accordance with AS/NZS 3823.1.1, AS/NZS 3823.1.2, AS/NZS 3823.1.3 or
AS/NZS 3823.3, for each model tested, shall be held by the appliance supplier.
The documents required by this Section shall be made available to the relevant regulatory
authority upon request. Records shall be retained until at least five years after the last date
of manufacture or import, whichever is applicable. A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 24

COPYRIGHT
4.3 DATE OF MANUFACTURE INFORMATION
The date of manufacture may be non-encrypted, encrypted or able to be determined from a
serial number or other markings on the appliance and shall be visible when the appliance is
in its position of normal use. Information on how to determine the date of manufacture shall
be provided on the registration form (see Appendix C).
NOTES:
1 Regulators will use the date of manufacture as a guide as to when a product may have been
available for sale in Australia. It is therefore preferable to be able to determine at least the
month and year of manufacture from information on the appliance. This does not however
preclude the use of other markings, for example serial numbers, which indicate those
appliances manufactured within a period of time, with such details given on the registration
form.
2 Irrespective of the information marked on the appliance, local manufacturers or importers
may be required to provide evidence of the actual manufactured or imported date if requested
by a regulator.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
25 AS/NZS 3823.2:2005

COPYRIGHT
S E C T I O N 5 P R I N T I N G A N D P L A C E M E N T O F
E N E R G Y L A B E L S
5.1 PLACEMENT
The label shall be adhered, or attached as a swing tag, on the front of the unit or display
front. The label may be attached to the exterior of the packaging. The label shall be
attached to the unit when the unit is removed from its packaging for display purposes.
5.2 MATERIAL AND SHAPE
The label shall be of durable cardboard, if it is to be attached as a swing tag, or be self-
adhesive and shall be cut to one of the outlines shown in Figures 5.2, 5.3 or 5.4, as
applicable. A trim or die cut margin of up to 2 mm around the label is acceptable.
5.3 COLOURS
5.3.1 Cooling only label
The cooling only label shall be of a white background, and shall be printed in the following
four colours (see Figure 5.2):
(a) Pantone 300 (Blue).
(b) Pantone Black.
(c) Pantone 116 (Yellow).
(d) Pantone 340 (Green).
5.3.2 Heating and cooling label
The heating and cooling label shall be of a white background, and shall be printed in the
following five colours (see Figure 5.3):
(a) Pantone 300 (Blue).
(b) Pantone Black.
(c) Pantone Warm Red.
(d) Pantone 116 (Yellow).
(e) Pantone 340 (Green).
5.3.3 Heating only label
The heating only label shall be of a white background, and shall be printed in the following
four colours (see Figure 5.4):
(a) Pantone Warm Red.
(b) Pantone Black.
(c) Pantone 116 (Yellow).
(d) Pantone 340 (Green).
5.3.4 Electric heating
Where a unit incorporates user-controlled electric heating devices, the note shown in
Figure 5.1 shall be included on the label. The text of the note shall be printed in
Pantone Warm Red (see Figure 5.1, Note 2) under the power input.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 26

COPYRIGHT
Where the unit has manually switchable electric heating devices as its sole form of heating,
a cooling only label shall be used. Where the unit has manually switchable electric heating
devices as supplementary heating, a heating and cooling label shall be used.
NOTE: User-controlled electric heating devices are not included in the determination of unit
energy performance, while automatically controlled devices are included.
5.4 LABEL REQUIREMENTS
The font shall be Gill Sans, Humanist 521 or Hammersmith. The preferred font is Gill Sans
as illustrated in the Figures. Only one font shall be used on a label. The fields (a), (b), (c),
(d) and (e) of Figure 5.1 shall comply with the following requirements:
(a) Field a This band shall terminate according to the appliances star rating, either
bisecting the relevant star for a rating of half a star or, for a rating of only full stars,
bisecting the gap between the relevant star and the next highest on the scale.
(b) Field b The brand and the model designation shall be inserted here. The wording
should be complete and concise. The lines shall not exceed a measure of 65 mm. They
should have normal spacing of letter, line and word and they shall be centred
horizontally in the area allowed. In the case of split systems, where the indoor and
outdoor components have different model numbers, model numbers for both shall
appear on the label.
(c) Field c This panel shall contain the rated total cooling capacity and rated heating
capacity, as applicable (capacity output), and the comparative energy consumption
(CEC) (power input) for cooling and heating, as applicable. The Figures that apply to
the particular appliance shall be of the font and size indicated and shall be centred in
the blue panel for cooling and the red panel for heating. The spacing between the
figures of a three-figure number is the same as for a four-figure number.
(d) Field d All models shall include this text and the associated check boxes. Yes shall
be ticked if the model meets the requirements of Clause 3.8. Otherwise, No shall be
ticked.
(e) Field e This panel shall form a solid green bar. Where the product has qualified for
and has been approved to receive a TESAW award, the text shown in Figure D4 for
the relevant award year may be shown on the energy label. Appendix D shows
additional information about label dimensions for this option.
NOTE: In addition to the requirements of this Section, label dimensions should be in accordance
with Appendix D. Additional material to assist in the printing of labels may be available from,
and any queries regarding such should be directed to, the relevant regulatory authority.
5.5 SAMPLE LABELS
Examples of printed energy labels for airconditioning appliances are shown in Figures 5.2,
5.3 and 5.4.

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
27 AS/NZS 3823.2:2005

COPYRIGHT

NOTES:
1 The preferred label width is 90 mm. For online printing, the external diameter of the red/blue star rating
arch may be reduced to 86 mm to allow for a 2 mm registration error such that the red print does not
extend over the label edge or result in a white band underneath it (see Appendix D).
2 This text shall be omitted if there is no user-controlled electric heating device installed (see Clause 5.3.4).
3 The fields (a), (b), (c), (d) and (e) of this Figure shall contain the information as required by Clause 5.4.
4 Font definitions for the reverse cycle label in this Figure are applicable to cooling only and heating only
labels.
5 See Clause 5.3 for specification of colours. On some printers and display devices, the colours in this
sample label may appear different to those specified.
FIGURE 5.1 DETAILS OF LABELHEATING AND COOLING UNIT
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 28

COPYRIGHT

NOTE: See Clause 5.3 for specification of colours. On some printers and display devices, the colours in this
sample label may appear different to those specified.
FIGURE 5.2 EXAMPLE OF LABELCOOLING ONLY UNIT
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
29 AS/NZS 3823.2:2005

COPYRIGHT

NOTE: See Clause 5.3 for specification of colours. On some printers and display devices, the colours in this
sample label may appear different to those specified.
FIGURE 5.3 EXAMPLE OF LABELHEATING AND COOLING UNIT
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 30

COPYRIGHT

NOTE: See Clause 5.3 for specification of colours. On some printers and display devices, the colours in this
sample label may appear different to those specified.
FIGURE 5.4 EXAMPLE OF LABELHEATING ONLY UNIT


A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
31 AS/NZS 3823.2:2005

COPYRIGHT
APPENDIX A
EXAMPLES OF ENERGY EFFICIENCY CALCULATIONS
(Informative)
A1 GENERAL
This Appendix provides an example of energy efficiency calculations. Paragraphs A2 and
A3 show the calculations involved in the determination of the energy label details for a
hypothetical single-phase reverse cycle household airconditioner for MEPS and energy
labelling and the determination of CEC, SRI and star rating. Paragraph A4 shows the
calculations involved in the determination of MEPS testing and compliance for a
hypothetical reverse-cycle three-phase split packaged airconditioner.
A2 TEST RESULTS, AVERAGES AND RATED VALUES
A hypothetical single-phase reverse cycle window/wall household airconditioner is
considered for MEPS and energy labelling.
On cooling, it has a rated capacity of 4.45 kW with a rated power input of 1.61 kW.
On heating, it has a rated capacity of 4.75 kW with a rated power input of 1.64 kW.
This unit is a single-phase airconditioner within the scope of AS/NZS 3823.1.1 and
according to Appendix E, compliance requirements are for labelling and MEPS (L).
Data from testing one sample in accordance with AS/NZS 3823.1.1 is shown in Tables A1
and A2. Values are for CONDITION T1 for cooling and CONDITION H1 for heating.
Before the energy labelling details are calculated, the unit should be checked for MEPS
compliance.
A2.1 Verification of MEPS requirements
In order to verify that this particular model complies with MEPS, the unit is required to
exceed the MEPS levels for that model as listed in Table 3.1. The tested EER in Table A1 is
2.689 while the rated EER is 2.764.
This unit complies with the MEPS requirements for 2004 (single-phase reverse cycle non-
ducted) as the rated and tested EER exceed the minimum EER specified in Table 3.1 (i.e.,
EER >2.3). While the rated value for EER just meets the MEPS 2006 requirements for
single-phase non-ducted non-split reverse cycle (i.e., EER >2.75), the test result does not
support this claim, so compliance with this requirement cannot be claimed.
A2.2 Verification of rated values
The test results should now be analysed to ensure that they verify the claimed rated values
as specified in Clause 2.3.3. For capacity and effective power input, the test value for the
test unit is compared with the rated values to ensure that they lie within the required units.
A summary of the verification comparisons for cooling and heating are contained in
Tables A3 and A4.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 32

COPYRIGHT
TABLE A1
COOLING TEST RESULTS
Specification Rated
Tested
unit 1
Cooling capacity (kW) 4.45 4.415
Effective power input (kW) 1.61 1.642
EER 2.764 2.689
TABLE A2
HEATING TEST RESULTS
Specification Rated
Tested
unit 1
Heating capacity (kW) 4.75 4.772
Effective power input (kW) 1.64 1.701
COP 2.896 2.805
TABLE A3
VERIFICATION OF RATED
COOLING SPECIFICATIONS
(PROPORTION OF RATED RESULT)
Tested/Rated Unit 1
Verification
limit for
each unit
Cooling capacity 0.992 0.95
Effective power input 1.020 1.05
NOTES:
1 The tested value for cooling capacity is greater than
0.95 of the rated capacity for each unit, so the rated
capacity is valid.
2 The tested value for effective power input is less
than 1.05 the rated power for each unit, so the rated
power is valid.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
33 AS/NZS 3823.2:2005

COPYRIGHT
TABLE A4
VERIFICATION OF RATED
HEATING SPECIFICATIONS
(PROPORTION OF RATED RESULT)
Tested/Rated Unit 1
Verification
limit for
each unit
Heating capacity 1.005 0.95
Effective power input 1.037 1.05
NOTES:
1 The tested value for heating capacity is greater
than 0.95 of the rated capacity for each unit, so
the rated capacity is valid.
2 The tested value for effective power input is less
than 1.05 the rated power for each unit, so the
rated power is valid.
A3 CALCULATION OF ENERGY LABEL VALUES
A3.1 Calculation of comparative energy consumption (CEC)
When the rated specifications have been verified, the CEC can be calculated from the rated
power.
CEC is calculated in accordance with Clause 2.4.
Example:
(a) CEC cooling = rated power
= 1.61 kW
(b) CEC heating = rated power
= 1.64 kW
A3.2 Calculation of Star Rating Index (SRI)
SRI for cooling and heating are calculated from the applicable equations in Clause 2.5.
Note that the tested values for EER and COP (not the rated values) are used to calculate
SRI.
Example:
(a) SRI cooling = [ (EERav 10) 17 ] / 3
= [ (2.689 10) 17 ] / 3
= 3.2967
(b) SRI heating = [ (COPav 10) 20 ] / 3
= [ (2.805 10) 20 ] / 3
= 2.6833
Star rating is as given in Table 2.1. Therefore, the cooling star rating for this model is 3.0
and the heating star rating for this model is 2.5.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 34

COPYRIGHT
A4 MEPS FOR AIRCONDITIONERS
A hypothetical reverse cycle three-phase split packaged airconditioner is considered for
MEPS.
On cooling, it has a rated capacity of 23.3 kW with a rated power input of 9.2 kW.
On heating, it has a rated capacity of 28.6 kW with a rated power input of 9.7 kW.
This unit is an airconditioner within the scope of AS/NZS 3823.1.1 and according to
Appendix E, and compliance requirements are for MEPS (M).
Data from testing a single sample in accordance with AS/NZS 3823.1.1 yields a result of
22.9 kW cooling capacity and an effective power input of 9.31 kW, yielding a tested EER
of 2.4597. Data from testing a single sample in accordance with AS/NZS 3823.1.1 yields a
result of 28.0 kW heating capacity and an effective power input of 9.9 kW, yielding a tested
COP of 2.8283.
Before MEPS compliance is verified, the test results should be analysed to ensure that they
verify the claimed rated values as specified in Clause 2.3.3. For capacity and effective
power input, the test values for each test unit are compared with the rated values to ensure
that they lie within the required limits. In this case the measured cooling capacity is 0.983
of the rated value and the effective power input is 1.012 of the rated value, so the claimed
values are valid. Similarly, the claimed heating results are valid.
The rated capacity of the model is 23.3 kW, therefore from Table 3.1 the MEPS 2001
requirement is that EER shall be > 2.45. As the tested value is 2.4597, which is greater than
2.45, the model complies with MEPS 2001. This unit does not comply with the MEPS
requirements for 2007, or the Class A Efficiency requirements specified in Table 3.3.

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
35 AS/NZS 3823.2:2005

COPYRIGHT
APPENDIX B
FORMAT OF APPLICATION FOR REGISTRATION OF AN
AIRCONDITIONER FOR ENERGY LABELLING AND MEPS
(Normative)
B1 INTRODUCTION
This Appendix sets out the required format for submitting an application for registration.
NOTES:
1 The contact details supplied by applicants in this form or online may be used by other
Government agencies to keep applicants informed of forthcoming regulatory changes that
may affect the product registered under this Standard. Otherwise, contact details are treated as
private and confidential.
2 NOTICE OF RIGHT TO DISCLOSE INFORATIONThe information you submit on this
application will be used for the purposes of assessing your application and the performance of
statutory responsibilities. The information, which you have submitted may be disclosed to
other state and territory or New Zealand energy efficient government bodies (or their agents)
who may use the information only for the purposes of carrying out their duties and or
responsibilities including comparing efficiency claims. The information will also be entered
onto the Online Registration Database. More information about this database is available at
www.energyrating.gov.au website.
B2 SCOPE
This Appendix sets out the required format for submitting an application for registration
and record keeping.
B3 GUIDANCE ON THE USE OF THIS APPLICATION FORM
The Appendix has been formatted and structured to align with the online registration system
for energy labelling and MEPS.
The preferred method of making an application for energy labelling and/or MEPS is via the
online registration system to ensure compliance with the most current registration
information requirements. To use this system, you need to apply for a user name and
password. Once a user name has been issued, you will have full access to the online system.
Details on how to apply for a user name and password and how to log on to the online
system can be found at www.energyrating.gov.au website.
B3.1 All registrations
If the unit meets a subsequent MEPS level in addition to the one currently in force, this
should be indicated in the application (refer to Section 4 for details). Only a single unit
needs to be tested and report submitted when applying for energy labelling to this Standard
(AS/NZS 3823.2:2005). Any units that carry an energy label shall be accompanied by a
physical test (simulation for energy labelling is not permitted). Any MEPS only application
may be accompanied by either a physical test or a simulation. Where energy labelling is not
mandatory, the applicant may choose to label the product on a voluntary basis, but all the
normal rules for energy labelling will apply (e.g., physical test is required).
B3.2 Submissions to the New Zealand regulator
Applicants who have listed their product with the New Zealand regulator and intend to rely
on the goods access provisions of the Trans Tasman Mutual Recognition Arrangement to
sell that product in Australia without registering it with an Australian regulator shall
comply with the following conditions: A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 36

COPYRIGHT
(a) The company responsible for the manufacture or importation of this product shall
have its registered offices in New Zealand.
(b) In respect of the product imported or manufactured by the applicant, this product
shall be either imported into New Zealand (but not directly into Australia) or
manufactured in New Zealand (not in Australia).
(c) If this product is imported into Australia, then it shall be imported through
New Zealand.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
37 AS/NZS 3823.2:2005

COPYRIGHT
B4 APPLICATION FORM
APPLICATION FOR REGISTRATION OF
AN AIRCONDITIONER FOR ENERGY EFFICIENCY
(Please type or print)
SECTION 1 APPLICATION DETAILS
I hereby apply for registration of an electrical appliance/s for the purpose of energy labelling
(where applicable) and MEPS.

SECTION 2 APPLICANT DETAILS
Name of applicant:


Company name:


Company address:



Name:

Address:

Position/Title:

Telephone:

Facsimile:

Contact person:
(A name, address
and contact details
for a person in
Australia or
New Zealand shall
be provided)
E-mail:

The Standard to which this application is
made?
AS/NZS 3823.2 (2003)
AS/NZS 3823.2 (2005)
What is this application for? MEPS only/Labelling and
MEPS
Is this product to be used exclusively for
commercial applications?
Yes/No
Is the application for a single model or a
family of models?
Single/Family
(indicate correct answer)

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 38

COPYRIGHT
SECTION 3 DESCRIPTION OF APPLIANCE
Brand name:


System
Name
Indoor Unit* Outdoor
Unit*
Model 1
Model 2
Model 3
Model designation (List all models
covered by this application. This
can either be a number or name or
combination of the two that will
identify the particular product. Add
additional rows if more than 3
models)

* Indicate only for split systems
Family model designation, if
applicable, for above models:

Model/family number(s) to appear
on the energy rating label where
provided and on the energyrating
website:
(indicate correct answer)
Display
List of individual models noted above
Or
Family model designation noted above
Country of manufacture:

Australia/NZ/Otherplease specify
Where is this product to be sold:
(indicate each country)

NOTE: The response will determine
how the model will be displayed on
Government energy rating websites in
Australia and New Zealand. If a model
is not indicated as being available in a
country, that model will not appear on
websites specific to that country.
Australia
New Zealand
Others
(See pick list on electronic registration system)
Year and month in which model
first available in Australia or
New Zealand:
Year Month
Date of manufacture traceability (of
package unit or indoor unit if split
system):
Is the date of manufacture
permanently marked on the rating
plate in a non-encrypted format?


Yes
Date format:


No
Provide details:
If yes, provide an example of the
date format.

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
39 AS/NZS 3823.2:2005

COPYRIGHT
If no, provide details on how to
determine (from the serial number
or other permanent markings for
this model) whether the date of
manufacture was either

(a) in the 5 year period prior to
the introduction of MEPS; or

(b) in the 5 year period
subsequent to the
introduction of MEPS.

Date of manufacture traceability (of
outdoor unit if split system):
Is the date of manufacture
permanently marked on the rating
plate in a non-encrypted format?


Yes
Date format:


No
Provide details:
If yes, provide an example of the
date format.

If no, provide details on how to
determine (from the serial number
or other permanent markings for
this model) whether the date of
manufacture was either

(a) in the 5 year period prior to
the introduction of MEPS; or

(b) in the 5 year period
subsequent to the
introduction to MEPS.

Does this model or family replace
or supplement another model or
family with identical energy
consumption and energy efficiency
rating?
(indicate correct answer)
Yes/No
If yes, indicate relevant details: Model name Model number Registration
number


A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 40

COPYRIGHT
SECTION 4 TESTING AND TEST REPORT
Is a test report or a summary
report in accordance with
Appendix C attached?
(indicate correct answer)
YesA single physical test report is attached
YesA simulation test report is attached
YesA summary report to Appendix C is attached
NoNo test reports are attached
If no report is attached, note the
source registration number of the
appliance upon which this
application relies for its report:
(proceed to Section 5 if no report
attached)

Test laboratory type:
(indicate correct answer)
Own in-house laboratory:
Independent laboratory:

Test laboratory name:


Test laboratory address:



Test laboratory location:
(indicate correct answer)
Australia:
New Zealand:
Other(please specify):

Test laboratory accreditation:


NATA
NATA recognized (please specify)
Unknown/none
Other(please specify):

Test Standard used:
(indicate relevant Standard, year,
revision and any amendment)
AS/NZS 3823.1.1 (non-ducted)
AS/NZS 3823.1.2 (ducted)
AS/NZS 3823.1.3 (water sourced/cooled)
AS/NZS 3823.3 (simulation)
Other (please specify)

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
41 AS/NZS 3823.2:2005

COPYRIGHT
Modelling software used (a) Nil (physical test report/s supplied)
(b) Oakridge softwareNOT using default
settings
(c) Oakridge softwareusing default settings (HP
Rate File Lodged with this application)
NOTE: HPRATE and Oakridge MK III
and IV do not support modelling of
certain airconditioner types such as
window wall models, unitary systems
where there is thermal interaction of
the components, any heat mode
where defrosting occurs, models with
water cooled condensers

If Oakridge software was used,
which version was used?
MK III MK IV MK V
Test report numbers:
(fill in as applicable)


Does this airconditioner have
separate indoor and outdoor
units?
Yes/No
Test room indoor type used:
Calorimeter/Enthalpy test room/not applicable
(simulation)
Test room outdoor type used:
Calorimeter/Enthalpy test room/water loop
equipment/not applicable (simulation)
Test
unit

SERIAL
NUMBER
Unitary unit or
indoor unit if split
system
SERIAL
NUMBER
Outdoor unit if
split system
Test
date


Serial number of test units/s and
date tested:
(Fill in fields as applicable to the
applicationUnit 2 and 3 only
need to be filled in for labelling
applications to the 2001
Standard)

Rated voltage and frequency of
tested unit/s
Unitary unit or
indoor unit if
split system
Outdoor unit if
split system
Rated voltage
range (V)

Rated frequency
(Hz)

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 42

COPYRIGHT
Tested voltage and frequency of
tested unit/s
Unitary unit or
indoor unit if
split system
Outdoor unit if
split system
Tested voltage
(V)

Test frequency
(HZ)

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
43 AS/NZS 3823.2:2005

COPYRIGHT
SECTION 5 SPECIFIC APPLICANCE DETAILS
Appliance dimensions
(Advisory only):
(for split systems note only
dimensions of the internal unit)
Width (mm): Height (mm): Depth (mm):
Airconditioner type:
(indicate correct answer)
Cooling only
Reverse cycle
Heating only
Power supply: Single-phase
Three-phase
Refrigerant: R22, R114, R502, R134, R32, R123, R124, R125
R143A, R152A, R290, R410A, R3212560, R507
R14312555, R404, R407
Other (please specify)
A/C Configuration 1Air
distribution:
(indicate correct answer)
Ducted/Non ducted
A/C Configuration 2Type:
(indicate correct answer)
Window/Wall
Spot cooler
Portable cooler
Single split system
Double/triple split system
Multiple split system
Packaged
Non-ducted split system indoor
unit mounting:
Wall-hung
Under ceiling
Floor mounted
Cassette
Floor/Ceiling
A/C configuration 3Heat
transfer:
(indicate correct answer)
Heat source (heating)
Air
Cooling tower
(Reversible)
Water loop (refer
AS/NZS 3823.1.3)
Ground water or
Ground loop (refer
AS/NZS 3823.1.3)
N/ACooling only

Heat sink (cooling)
Air
Cooling tower
Water loop (refer
AS/NZS 3823.1.3)
N/AHeating only
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 44

COPYRIGHT
Does this airconditioner have a
variable output compressor? (e.g.
variable speed drive (inverter) or
a multi-speed compressor)
(indicate correct answer)
Yes/No
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
45 AS/NZS 3823.2:2005

COPYRIGHT
SECTION 6 TEST RESULTS
TEST RESULTSCOOLINGCONDITION T1
COOLING
POWER
Rated effective power input (kW)*
Labelled CEC (kW)*
(Fill in for labelling applications only)

Tested cooling power inputTest 1 (kW)**


COOLING
CAPACITY
Rated sensible cooling capacity (kW)*


Rated dehumidifying effect (kW)*
NOTE: 1 litre water extracted per hour = 0.683 kW

Rated total cooling capacity (kW)*


Tested total cooling capacityTest 1 (kW)**


EER EERTest 1**
Does the air-cooled condenser evaporate the condensate?
(indicate correct answer)
Yes/No
Indicate fan and any other settings for determination of rated capacity:
Indicate method of obtaining fixed output on airconditioners with variable
output capacity:
For ducted systems, indicate air flow rate (cubic metres/second):
For ducted systems, indicate static pressure (Pa):
Average power factor for the cooling test:
Does this model comply with the maximum cooling test for
Condition T1: (include correct answer)
Note this only applies to applications for energy labellingIf the
application is for MEPS only then select N/A.
Supply a test report on a single unit to support this claim (see Clause 2.9).
Yes/No/N/A
* to 2 decimal places
** to 3 decimal places
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 46

COPYRIGHT
TEST RESULTSHEATINGCONDITION H1
Does this model incorporate electric resistance heating?
(indicate correct answer)
Yes/No
HEATING
POWER
Rated effective power input (kW)*
Labelled CEC (kW)*
(Fill in for labelling applications only)

Tested heating power inputTest 1 (kW)**
(Fill in for labelling applications only)

HEATING
CAPACITY
Rated total heating capacity (kW)*
Tested heating capacityTest 1 (kW)**
(Fill in for labelling applications only)

COP COPTest 1**
(Fill in for labelling applications only)

Indicate fan and any other settings for determination of rated capacity:
For ducted systems, indicate air flow rate (cubic metres/second):
Indicate method of obtaining fixed output on airconditioners with variable
output capacity:

For ducted systems, indicate static pressure (Pa):
Average power factor for the heating test:

RESULT SUMMARYFor labelling applications only
COOLING HEATING
Tested EER** and COP** (as applicable):
Star Rating Index (see Clause 2.5):
Star Rating:
* to 2 decimal places
** to 3 decimal places



Does this model have a crank case heater? Yes/No
Average power in off mode (where applicable).
(Where present, off mode power shall include the energy
consumption of the crankcase heater measured at 20C
as defined in the relevant Part 1 Standard).
Watts
Average power in passive standby mode (where
applicable).
Where present, passive standby mode power shall include
the energy consumption of the crankcase heater
measured at 20C as defined in the relevant Part 1
Standard).
Watts
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
47 AS/NZS 3823.2:2005

COPYRIGHT
If a crankcase heater is present, state the average power
at an ambient of 7C in off mode (or in passive standby
mode if off mode is not applicable).
Include the energy consumption of the crankcase heater
defined in the relevant Part 1 Standard.
Watts
Data for both off mode and passive standby mode where
present. All products have at least one of these modes.
Refer to relevant Part 1 for definitions and conditions.

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 48

COPYRIGHT
SECTION 7 VOLUNTARY DECLARATIONLOW TEMPERATURE HEATING
PERFORMANCE
NOTE: At the time of the publication of this Standard the requirements of this Section were
under consideration by regulatory authorities.

SECTION 8 VOLUNTARY DECLARATIONVARIABLE OUTPUT COMPRESSOR
PERFORMANCE
NOTE: This Section is to be filled in only by those manufacturers that wish to indicate part
load performance of products that have a variable output compressors (e.g., multi-speed or
inverter-driven compressor) on the www.energyrating.gov.au website as set out in
Clause 3.8. Only EER and COP will be shown on the website.
Voluntary declarationPart load (50%)
(Applicable to applications to AS/NZS 3823.2 only for air-conditioners with variable
output compressors)
Have you supplied a test report for part load operation
as part of this application?
(indicate correct answer)
Yes/No
Do you want part load data to be indicated on the
energyrating website?
(indicate correct answer)
Yes/No
Part load test results
COOLING
POWER
(50% LOAD)
Tested cooling power input (kW)**

(Not applicable to heating only airconditioners)

COOLING
CAPACITY
(50% LOAD)
Tested total cooling capacity (kW)**
(Output should be in the range 50% to 60% rated
capacity)
(Not applicable to heating only airconditioners)

EER
(50% LOAD)
EER
(Not applicable to heating only airconditioners)

COOLING
CAPACITY
Where applicable indicate method of obtaining fixed
output on airconditioners with variable output
capacity

HEATING POWER
(50% LOAD)
Tested heating power input (kW)**
(Not applicable to cooling only airconditioners)

HEATING
CAPACITY
(50% LOAD)
Tested total heating capacity (kW)**
(Output should be in the range 50% to 60% rated
capacity)
(Not applicable to cooling only airconditioners)

COP
(50% LOAD)
COP
(Not applicable to cooling only airconditioners)

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
49 AS/NZS 3823.2:2005

COPYRIGHT
HEATING
CAPACITY
Where applicable indicate method of obtaining fixed
output on airconditioners with variable output
capacity.

** to 3 decimal places
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 50

COPYRIGHT
SECTION 9 MANDATORY DECLARATIONVARIABLE OUTPUT COMPRESSOR
MODELS
NOTE: This Section is to be filled in only by those manufacturers that are registering
products that have a variable output compressor to this Standard (AS/NZS 3823.2) for
MEPS compliance.
Indicate the setting and % of rated capacity used to
verify MEPS (refer to Clause 3.4)
Setting % of rated
capacity
The rest of this Section shall be completed if the MEPS compliance capacity is not 100%
of rated capacity. A test report shall be supplied at the % of rated capacity used to claim
compliance with MEPS.

Has a test report been supplied at the % of rated
capacity used to verify MEPS?
(indicate correct answer)
Yes/No
Cooling capacity used to verify MEPS compliance
(kW):
(% of rated capacity stated above)

Tested or modelled EER:
(% of rated capacity stated above)

Where applicable, indicate method of obtaining fixed
output on airconditioners with variable output capacity

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
51 AS/NZS 3823.2:2005

COPYRIGHT
SECTION 10 COMPLIANCE WITH MEPS
NOTE: This Section is to be filled in by all applicants.
Minimum energy performance standards (minimum efficiency) and high efficiency
declaration
MEPS are mandatory for all airconditioners except those that are exempt from the scope
of this Standard (see Clause 1.2). Detailed MEPS requirements are set out in Section 3.
Three-phase airconditioners that claim to be Class A efficiency after 1 October 2007 shall
also have to meet the requirements specified in Section 3.
Single-phase unit MEPS levels Min
EER
Does this model
comply?
(indicate correct answer)
Applicable 2004 MEPS level (minimum EER):
(see Table 3.1 or 3.2)
Yes/No
Applicable 2006 MEPS level (minimum EER):
(see Table 3.1 or 3.2)
Yes/No
Applicable 2007 MEPS level (minimum EER):
(see Table 3.1 or 3.2)
Yes/No
Applicable 2008 MEPS level (minimum EER):
(see Table 3.1 or 3.2)
Yes/No

Three-phase unit MEPS levels and Class A levels
Min
EER
Does this model
comply?
(indicate correct answer)
Applicable 2001 MEPS level (minimum EER):
(see Table 3.1 or 3.2)
Yes/No
Applicable 2007 MEPS level (minimum EER):
(see Table 3.1 or 3.2)
Yes/No
Class A efficiency level
(minimum EER):
(see Table 3.3) (applies to single and three phase)
Yes/No
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 52

COPYRIGHT
SECTION 11 DECLARATION
I declare that the details stated in this application are correct.
Signature of Applicant: .............................................. Date: ......................................

Office use only
Date received: Registration number:


A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
53 AS/NZS 3823.2:2005

COPYRIGHT
APPENDIX C
FORMAT OF SUMMARY TEST RESULTS FOR AN ENERGY LABELLING
AND/OR MEPS APPLICATION WHERE FULL TEST REPORTS ARE NOT
PROVIDED
(Informative)
This Appendix sets out the format for submitting summary test results for tests undertaken
for an energy labelling and/or MEPS application where full test reports to AS/NZS 3823.1.1
or AS/NZS 3823.1.2 or AS/NZS 3823.1.3 are not provided with the application. A separate
form should be prepared for each unit tested.

Airconditioner details
Brand:
Model name: (if applicable)
Model number: (of package unit or indoor unit if split system)
Model number: (of outdoor unit if split system)
A/C Configuration 1Air distribution Ducted/non-ducted
A/C Configuration 2Type Cooling only/heating only/cooling and heating
A/C Configuration 3Heat transfer Air/cooling tower/water loop
Non-ducted split system indoor unit
mounting
Wall-hung/Under ceiling/Floor
mounted/Casette/Floor/Ceiling
Serial number(s) of unit tested: (of package unit or indoor unit if split system)
Serial number(s) of unit tested: (of outdoor unit if split system)
Rated voltage: V (of package unit or indoor unit if split system)
Rated voltage: V (of outdoor unit if split system)
Rated frequency:
Rated cooling capacity (condition T1) (where applicable):
Rated effective power input, cooling (where applicable):
Rated heating capacity (condition H1) (where applicable):
Rated effective power input, heating (where applicable):
Does this airconditioner use a variable output compressor (e.g., speed drive or multi-speed
compressor)?

Test summary
Complete a separate copy of this page for each test type, as applicable, i.e., cooling,
heating and maximum cooling tests.
Date of test:
Test officer:
Test mode: Cooling only/heating only/cooling and heating
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 54

COPYRIGHT
Test type: Cooling capacity/heating capacity/maximum cooling/all
applicable tests
Test room type indoor
equipment:
Calorimeter/Enthalpy test room
Test room type outdoor
equipment:
Calorimeter/Enthalpy test room/Water loop
Test Standard: AS/NZS 3823.1.1/AS/NZS 3823.1.2/ AS/NZS 3823.1.3
Test mode: Cooling/heating/maximum cooling
Supply voltage: V (of package unit or indoor unit if split system)
Supply voltage: V (of outdoor unit if split system)
Supply frequency: Hz
Average current (amps): (Single-phase units or Phase 1 for three-phase)
Average current (Amps): Phase 2 Phase 3 (Three-phase units only)
Stabilization period (minutes):
Test period (minutes):
Indoor condition mean dry bulb (C):
Indoor condition maximum variation dry bulb (max min) (C):
Indoor condition mean wet bulb (C): (where applicable)
Indoor condition maximum variation wet bulb (max min) (C): (where applicable)
Fan setting:
Average air flow volume (m
3
/hour):
Indoor external static pressure (Pa): (ducted units only)
Outdoor condition mean dry bulb (C):
Outdoor condition maximum variation dry bulb (max min) (C):
Outdoor condition mean wet bulb (C):
Outdoor condition maximum variation wet bulb (max min) (C):
Reading frequency (minutes):
Water inlet temperaturemean (C): (water loop and water cooled)
Water outlet temperaturemean (C): (water loop and water cooled)
Water flow ratemean (litre/minute): (water loop and water cooled)
Circulation pumphas this power been included in the effective power input?: (water loop
and water cooled)
Reading frequency (minutes):

Cooling capacity results
Measured sensible cooling capacity (W):
Measured latent cooling capacity (W):
Measured total cooling capacity (W):
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
55 AS/NZS 3823.2:2005

COPYRIGHT
Measured effective power input (W):
Measured EER cooling (W/W):

Heating capacity results
Measured heating capacity (W):
Measured effective power input (W):
Measured COP heating (W/W):
Did the unit enter a defrost cycle during the test?: Yes/No
If so, what is the average interval between defrosts? (minutes)

Maximum cooling results
Was there any obvious damage to the equipment during the test? Yes/No
Did the motor overload protection trip within the first hour after power was restored? Yes/No
If yes, how many times did the unit trip?:
At what time did the first trip occur (minutes after power restored): (minutes)
Was the airconditioner tested with an air filter installed? Yes/No

Recommended additional data to be collected for checktests
Discharge pressure and equivalent temperature:
Discharge line temperature:
Discharge superheat:
Liquid/suction line lengths:
Liquid line temperature:
Suction pressure and equivalent temperature:
Suction line temperature:
Power consumptionevaporator fan motor:
Power consumptionCondensing unit:

Standby modes
Does this model have a crankcase heater? Yes/No
Off mode power consumption Watts (at 20C if product has a crankcase heater):
If the product has a crankcase heater, off/standby mode power consumption, watts, at 7C:
Passive standby power consumption Watts (at 20C if product has a crankcase heater):
Passive standby power mode description (add variation as required):

DECLARATION
I declare that the details stated in this test report summary are correct and are based on a
test report which we hold.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 56

COPYRIGHT
Test report number/reference
Signature of Test
Officer:
..................................
Date: (dd/mm/yyyy)

A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
57 AS/NZS 3823.2:2005

COPYRIGHT
APPENDIX D
ENERGY LABEL DIMENSIONS
(Informative)
Figures D1, D2 and D3 of this Appendix provide most of the dimensional information
required to create a valid energy label. The font sizes are specified in Figure 5.1.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 58

COPYRIGHT

NOTES:
1 The preferred label width is 90 mm. For online printing, the external diameter of the blue star rating arch
may be reduced to 86 mm to allow for a 2 mm registration error such that the blue print does not extend
over the label edge or result in a white bend underneath it.
2 See Clause 5.3 for specification of colours. On some printers and display devices, the colours in this
sample label may appear different to those specified.
FIGURE D1 ENERGY LABEL DIMENSIONSCOOLING UNIT ONLY
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
59 AS/NZS 3823.2:2005

COPYRIGHT

NOTES:
1 The preferred label width is 90 mm. For online printing, the external diameter of the red/blue
star rating arch may be reduced to 86 mm to allow for a 2 mm registration error such that the
red/blue print does not extend over the label edge or result in a white bend underneath it.
2 Where the text (not using user-controlled electric heating devices) is included under the
power input, the distance from the base of the power input (red box) to the bottom of the
white box is increased from 7 mm to 10 mm (see Clause 5.3.4 regarding when this text is
required).
3 See Clause 5.3 for specification of colours. One some printers and display devices, the
colours in this sample label may appear different to those specified.
FIGURE D2 ENERGY LABEL DIMENSIONSHEATING AND COOLING UNIT A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 60

COPYRIGHT

NOTES:
1 The preferred label width is 90 mm. For online printing the external diameter of the red star rating arch
may be reduced to 86 mm to allow for a 2 mm registration error such that the red print does not extend
over the label edge or result in a white bend underneath it.
2 Where the text (not using user-controlled electric heating devices) is included under the power input, the
distance from the base of the power input (red box) to the bottom of the white box is increased from 7 mm
to 10 mm (see Clause 5.3.4. regarding when this text is required).
3 See Clause 5.3 for specification of colours. On some printers and display devices, the colours in this
sample label may appear different to those specified.
FIGURE D3 ENERGY LABEL DIMENSIONSHEATING ONLY UNIT
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
61 AS/NZS 3823.2:2005

COPYRIGHT

FIGURE D4 ENERGY LABEL DIMENSIONSINCORPORATING TESAW
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 62

COPYRIGHT
APPENDIX E
ENERGY LABELLING AND MEPS REQUIREMENTS FOR VARIOUS
AIRCONDITIONING EQUIPMENT CONFIGURATIONS
(Normative)
The following program elements (shown in Table E1) shall be applicable to airconditioners:
(a) LMandatory energy labelling from the date given in Table E1 and mandatory
MEPS from 1 October 2004.
(b) MMandatory MEPS from the date given in Table E1 and voluntary energy
labelling.
See Tables 3.1 and 3.2 for actual MEPS values that are required to be met by different unit
types and cooling capacities.
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
63 AS/NZS 3823.2:2005

COPYRIGHT
TABLE E1
ENERGY LABELLING AND MEPS REQUIREMENTS FOR VARIOUS
AIRCONDITIONING EQUIPMENT CONFIGURATIONS
Type Description
Examples
(not all)
Conf. Phase Application
Compliance
requirement
and date
a


Household
L
b

Prior to October 2001

1
Commercial
M
From October 2004
Household
Window/
Wall
A single encased
assembly designed
for mounting in a
window or through
a wall

Non-
ducted
3
Commercial
M
Since October 2001
Household
1
Commercial
Household Spot cooler
A single encased
assembly that
discharges
conditioned and
condenser exhaust
air into the same
space
Portable device
used in
factories to
blow cool air
onto an
assembly
worker
Non-
ducted
3
Commercial
Exempted
Household

1
Commercial
Household
Portable
ducted
unbalanced
Single cased
assembly which
draws air from the
conditioned space
and exhausts this
through a duct

Ducted
3
Commercial
Exempted
Wall hung
portable
balanced
A single encased
assembly that
draws air from
outside and
discharges to
outside.
Portable device
attached to
special small
wall ducts
assembly lies
wholly within
conditioned
space
Non-
ducted
1 or 3
Household or
Commercial
L
b

Prior to October 2001
M
From October 2004
Household
L
b

Prior to October 2001
1
Commercial
M
From October 2004
Household
Wall-hung split
Under ceiling
split
Cassette split
Floor console
Remote
condenser
Portable
Non-
ducted
3
Commercial
M
Since October 2001
Household
M
bc

From October 2004
Ducted split
system
1
Commercial
M
From October 2004
Household
Split
systems
A system
comprised of an
outdoor unit and
an indoor unit
interconnected by
refrigeration
piping
Add-on cooling
for ducted gas
heating
Ducted
3
Commercial
M
Since October 2001
Household

1
Commercial
Household
Multi-
split
system
A split system
having two or
more indoor units,
each indoor unit
being capable of
being controlled
independently

Ducted
and
non-
ducted 3
Commercial
Under consideration
(continued) A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 64

COPYRIGHT
Type Description
Examples
(not all)
Conf. Phase Application
Compliance
requirement
and date
a


Household
L
b

Prior to October 2001

1
Commercial
M
From October 2004
Household

Non-
ducted
3
Commercial
M
Since October 2001

Household
M
bc

From October 2004

1
Commercial
M
From October 2004
Household
Twin/
Triple split
system
A split system
comprised of a
single outdoor unit
with two (or three)
indoor units that
are controlled by a
single controller

Ducted
3
Commercial
M
Since October 2001
Household
M
bc

From October 2004
1
Commercial
M
From October 2004
Household
Single
package
unit
A single encased
assembly situated
remote to the
space to be
conditioned, which
supplies/
extracts air from
the conditioned
space through duct
Roof top unit Ducted
3
Commercial
M
Since October 2001
Household
M
bc

From October 2004
1
Commercial
M
From October 2004
Household
Devices that
use cooling
towers
Water cooled
condensers
Ducted
3
Commercial
M
Since October 2001
Household
L
b

Prior to October 2001
1
Commercial
M
From October 2004
Household
Water
cooled unit
A split or single
packaged system
where the
condenser heat is
removed by water
and subsequently
cooled by air
Devices that
use cooling
towers
Water cooled
condensers
Non-
ducted
3
Commercial
M
Since October 2001
(continued)
TABLE E1 (continued)
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
65 AS/NZS 3823.2:2005

COPYRIGHT
Type Description
Examples
(not all)
Conf. Phase Application
Compliance
requirement
and date
a


Household
M
bc

From October 2004
Water loop heat
pumps
d

1
Commercial
M
From October 2004
Household

Ducted
3
Commercial
M
Since October 2001

Household
L
b

Prior to October 2001
Water loop heat
pumps
d

1
Commercial
M
From October 2004

Household
M
Since October 2001
Water
source heat
pump
A split or single
packaged system
where the
condenser heat
(cooling) or
evaporator heat
(heating) is
transferred to or
from water

Non-
ducted
3
Commercial
M
Since October 2001
Household
1
Commercial
Household
Close
controlled
air-
conditioner
See Clause 1.6.3
Computer room
airconditioner
Ducted
and
non-
ducted 3
Commercial
Exempted until 2007
a MEPS requirements shown as October 2001 were not mandatory in New Zealand until 1 July 2002.
b Mandatory energy labelling (L) for these systems was limited to 7.5 kW units up to October 2001 (single
or three-phase) and was altered to cover all single-phase models only from October 2001.
c Mandatory energy labelling (L) without MEPS is applicable prior to the introduction of MEPS (M) on the
nominated date.
d Ground water heat pumps and ground loop heat pumps defined in AS/NZS 3823.1.3 are exempt.
TABLE E1 (continued)
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 66

COPYRIGHT
APPENDIX F
NEW ENERGY LABELLING ALGORITHMS
(Informative)
The following energy labelling algorithms will replace the star rating equations in
Clause 2.5. These will be introduced in early 2008 and will apply to all products registered
from April 2008. A transition period for the new label for product on display will apply
until late 2008.
SRI cooling2008
The SRI cooling is calculated by the following equation:
SRI cooling = [(Tested average EER 8) 18]/4 . . . F(1)
SRI heating2008
The SRI for heating is calculated by the following equation:
SRI heating = [(Tested average COP 8) 18]/4 . . . F(2)
This equates to a 1 star line at and EER/COP of 2.75 with an increase of 0.5 per additional
star.
These equations have been revised for adoption with the more stringent MEPS levels come
into force in late 2008. These equations and associated changes to the energy label will be
included in a revision of this Standard in 2006/2007. If you have any comments on these
algorithms, contact the Australian Greenhouse Office on energy.rating@deh.gov.au
website.


A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
67 AS/NZS 3823.2:2005


NOTES
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6
AS/NZS 3823.2:2005 68


NOTES
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6


Standards Australia
Standards Australia is an independent company, limited by guarantee, which prepares and publishes
most of the voluntary technical and commercial standards used in Australia. These standards are
developed through an open process of consultation and consensus, in which all interested parties are
invited to participate. Through a Memorandum of Understanding with the Commonwealth
government, Standards Australia is recognized as Australias peak national standards body.
Standards New Zealand
The first national Standards organization was created in New Zealand in 1932. The Standards
Council of New Zealand is the national authority responsible for the production of Standards.
Standards New Zealand is the trading arm of the Standards Council established under the Standards
Act 1988.
Australian/New Zealand Standards
Under a Memorandum of Understanding between Standards Australia and Standards New Zealand,
Australian/New Zealand Standards are prepared by committees of experts from industry,
governments, consumers and other sectors. The requirements or recommendations contained
in published Standards are a consensus of the views of representative interests and also take
account of comments received from other sources. They reflect the latest scientific and industry
experience. Australian/New Zealand Standards are kept under continuous review after publication
and are updated regularly to take account of changing technology.
International Involvement
Standards Australia and Standards New Zealand are responsible for ensuring that the Australian
and New Zealand viewpoints are considered in the formulation of international Standards and that
the latest international experience is incorporated in national and Joint Standards. This role is vital
in assisting local industry to compete in international markets. Both organizations are the national
members of ISO (the International Organization for Standardization) and IEC (the International
Electrotechnical Commission).
Visit our web sites
www.standards.org.au www.standards.co.nz
www.standards.com.au
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6




GPO Box 476 Sydney NSW 2001
Administration
Phone (02) 8206 6000
Fax (02) 8206 6001
Email mail@standards.com.au
Customer Service
Phone 1300 65 46 46
Fax 1300 65 49 49
Email sales@standards.com.au
Internet www.standards.org.au
Level 10 Radio New Zealand House
155 The Terrace Wellington 6001
(Private Bag 2439 Wellington 6020)
Phone (04) 498 5990
Fax (04) 498 5994
Customer Services (04) 498 5991
Information Service (04) 498 5992
Email snz@standards.co.nz
Internet www.standards.co.nz
ISBN 0 7337 7077 0 Printed in Australia
A
c
c
e
s
s
e
d

b
y

R
M
I
T

U
N
I
V
E
R
S
I
T
Y

L
I
B
R
A
R
Y

o
n

2
9

M
a
r

2
0
0
6





















This page has been left blank intentionally.