ANALISIS DE DEMANDA POR EL METODO ARITMETICO

Nmero de viviendas
N habitantes x vivienda
Dotacin
Tasa de crecimiento
K1
K2
Poblacin en el 2012

aos

Horizonte

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032

560
2.88
180
2.06%
1.3
1.8
1612

2.06
1612
1,645
1,678
1,712
1,745
1,778
1,811
1,844
1,878
1,911
1,944
1,977
2,010
2,044
2,077
2,110
2,143
2,177
2,210
2,243
2,276

viv.
hab/viv
l/habxda

para centros poblados

Segn RNE
segn encuesta socioeconmica elaborada en Junio de 2012

180.00
Qp
3.36
3.43
3.50
3.57
3.64
3.70
3.77
3.84
3.91
3.98
4.05
4.12
4.19
4.26
4.33
4.40
4.46
4.54
4.60
4.67
4.74

1.30
Qmd
4.37
4.46
4.55
4.64
4.73
4.81
4.90
4.99
5.08
5.17
5.27
5.36
5.45
5.54
5.63
5.72
5.80
5.90
5.98
6.07
6.16

2.50
Qmh
8.4
8.58
8.75
8.93
9.10
9.25
9.43
9.60
9.78
9.95
10.13
10.30
10.48
10.65
10.83
11.00
11.15
11.35
11.50
11.68
11.85

0.80
Qd
6.72
6.86
7.00
7.14
7.28
7.40
7.54
7.68
7.82
7.96
8.10
8.24
8.38
8.52
8.66
8.80
8.92
9.08
9.20
9.34
9.48

0.25
Vregul.
72.58
74.09
75.60
77.11
78.62
79.92
81.43
82.94
84.46
85.97
87.48
88.99
90.50
92.02
93.53
95.04
96.34
98.06
99.36
100.87
102.38

0.10
V.reserva
0
38.53
39.31
40.09
40.87
41.56
42.34
43.11
43.89
44.67
45.53
46.31
47.09
47.87
48.64
49.42
50.11
50.98
51.67
52.44
53.22

V.Alm
72.58
112.62
114.91
117.20
119.49
121.48
123.77
126.05
128.35
130.64
133.01
135.30
137.59
139.89
142.17
144.46
146.45
149.04
151.03
153.31
155.60

ANALISIS DE DEMANDA POR EL METODO ARITMETICO


Nmero de viviendas
N habitantes x vivienda
Dotacin
Tasa de crecimiento
K1
K2

344 viv.
2.88 hab/viv
180 l/habxda
para centros poblados rurales
2.06%
1.3 Segn RNE
2.5
PARA EL AREA DE PRESIN N01
180.00
1.30
2.50
0.80
Qp
Qmd
Qmh
Qd
2.11
2.74
5.28
4.22
2.15
2.80
5.38
4.30
2.19
2.85
5.48
4.38
2.23
2.90
5.58
4.46
2.28
2.96
5.70
4.56
2.32
3.02
5.80
4.64
2.36
3.07
5.90
4.72
2.40
3.12
6.00
4.80
2.45
3.19
6.13
4.90
2.49
3.24
6.23
4.98
2.53
3.29
6.33
5.06
2.58
3.35
6.45
5.16
2.62
3.41
6.55
5.24
2.66
3.46
6.65
5.32
2.70
3.51
6.75
5.40
2.74
3.56
6.85
5.48
2.79
3.63
6.98
5.58
2.83
3.68
7.08
5.66
2.87
3.73
7.18
5.74
2.91
3.78
7.28
5.82

aos
2.06
0
991
1
1,011
2
1,032
3
1,052
4
1,072
5
1,093
6
1,113
7
1,134
8
1,154
9
1,174
10
1,195
11
1,215
12
1,236
13
1,256
14
1,276
15
1,297
16
1,317
17
1,338
18
1,358
19
1,378
20
1,399
ANALISIS DE CAUDALES
caudal promedio
Qprom =
Pob.futura x Dotacin/86400
Qprom =
2.91
l/s
caudal mximo diario
Qmd =
Qprom x K1
Qmd =

3.78
l/s
0.0038
m3/s
caudal mximo horario
Qmh =
Qprom x K2
Qmh =
7.28
l/s

Qmd REAL=

Qmd + perdidas(25%)

caudal de la oferta

Valm
69.25
70.63
71.93
73.22
74.82
76.20
77.50
78.80
80.48
81.78
83.07
84.67
86.05
87.35
88.65
89.94
91.63
92.92
94.22
95.52

=
=

CALCULO DEL DIAMETRO DE LA TUBERIA DE CONDUCCION


Para el clculo del dametro de la tubera de conduccin se utiliza la ecuacin de continuidad
Q=
donde:
Q:
V:
A:

V *A

Caudal mximo diario


velocidad del fluido, para veloc. Minimas de 0.6 m/s y velocidades mximas de 3m/s
Area de la tubera
velocidad recomend.
0.80
m/s
2
Q=
V**D /4
D=
(4Q/*V)1/2
D=
0.087
m
3 pulgadas
DN=
90mm
PVC-UF, ISO 4422-2, PN 7.5

METICO

s mximas de 3m/s

ANALISIS DE DEMANDA POR EL METODO A


Nmero de viviendas
216
N habitantes x vivienda
2.88
Dotacin
180
Tasa de crecimiento
2.06%
K1
1.3
K2
2.5
PARA EL AREA DE PRESIN N02
aos
2.06
180.00
0
622
Qp
1
635
1.32
2
648
1.35
3
661
1.38
4
673
1.40
5
686
1.43
6
699
1.46
7
712
1.48
8
725
1.51
9
737
1.54
10
750
1.56
11
763
1.59
12
776
1.62
13
789
1.64
14
801
1.67
15
814
1.70
16
827
1.72
17
840
1.75
18
853
1.78
19
866
1.80
20
878
1.83
ANALISIS DE CAUDALES
caudal promedio
Qprom =
Pob.futura x Dotacin/86400
Qprom =
1.83
l/s

4.73 l/s
4.04

caudal mximo diario


Qmd =
Qprom x K1

0.00473
l/s

Ok

cumple

Qmd =

2.38 l/s

caudal mximo horario


Qmh =
Qprom x K2
Qmh =

4.58

l/s

CALCULO DEL DIAMETRO DE LA TUBERIA DE CONDUCCION


Para el clculo del dametro de la tubera de conduccin se utiliza la ecua
Q=
donde:
Q:
V:
A:
Q=
D=
D=
DN=

V *A

Caudal mximo diario


velocidad del fluido, para veloc. Minimas de 0.6 m/s y veloc
Area de la tubera
V**D2 /4
(4Q/*V)1/2
0.08
m
75mm
PVC-UF, ISO 4422-2, PN 7.5

ANALISIS DE DEMANDA POR EL METODO ARITMETICO


viv.
hab/viv
l/habxda

para centros poblados rurales

Segn RNE

1.30
Qmd
1.72
1.76
1.79
1.82
1.86
1.90
1.92
1.96
2.00
2.03
2.07
2.11
2.13
2.17
2.21
2.24
2.28
2.31
2.34
2.38

2.50
Qmh
3.30
3.38
3.45
3.50
3.58
3.65
3.70
3.78
3.85
3.90
3.98
4.05
4.10
4.18
4.25
4.30
4.38
4.45
4.50
4.58

0.80
Qd
2.64
2.70
2.76
2.80
2.86
2.92
2.96
3.02
3.08
3.12
3.18
3.24
3.28
3.34
3.40
3.44
3.50
3.56
3.60
3.66

0.25+0.10
Valm
43.37
44.37
45.27
45.96
46.96
47.95
48.56
49.55
50.54
51.24
52.23
53.22
53.83
54.82
55.81
56.51
57.50
58.41
59.10
60.09

ra x Dotacin/86400

Qmd REAL=

Qmd + perdidas(25%)

2.98 l/s
0.0030 m3/s

ETRO DE LA TUBERIA DE CONDUCCION


metro de la tubera de conduccin se utiliza la ecuacin de continuidad

d del fluido, para veloc. Minimas de 0.6 m/s y velocidades mximas de 3m/s
velocidad recomendada.

3.13
pulgadas
PVC-UF, ISO 4422-2, PN 7.5

0.60

m/s

HARDY CROSS - AREA DE PRESION N 01


1.- METODO DE DENSIDAD POBLACIONAL
Este mtodo considera la poblacin por rea de influencia de cada nudo. Para la aplicacin de este
mtodo se debera definir la poblacin en cada sector del rea del proyecto.
El caudal por nudo ser
Qi=
Qp * Pi
donde el caudal unitario poblacional se calcula por:
Qp=
donde:
Qp
Qt
Qi
Pt
Pi
nudo

nudo

Qt / Pt

nudo

Manzana
C
G1
J1
J1'

Manzana
G
Q
V
Y

Manzana
U
X
O1
P1

Manzana
L
M
O
R

nudo

0.00520 l/s/hab

Caudal unitario poblacional l/s/hab


Caudal total o caudal mximo horario para la totalidad de la poblacin l/s
Caudal en el nudo "i" l/s
Poblacin total del proyecto hab.
Poblacin del r de influencia del nudo "i" hab.

nudo

Manzana
H
I
K1
N1

N viviendas
9
6
18
10

Dens.(hab/viv.)
2.88
2.88
2.88
2.88

43

N viviendas
21
22
20
16

Dens.(hab/viv.)
2.88
2.88
2.88
2.88

79

N viviendas
17
20
16
6

Dens.(hab/viv.)
2.88
2.88
2.88
2.88

59

N viviendas
12
20
21
19

Dens.(hab/viv.)
2.88
2.88
2.88
2.88

72

N viviendas
20
16
14
9

Dens.(hab/viv.)
2.88
2.88
2.88
2.88

59

T.C.P

Pi

0.0206
0.0206
0.0206
0.0206

T.C.P

Pi

0.0206
0.0206
0.0206
0.0206

T.C.P

Pi

T.C.P

0.0206
0.0206
0.0206
0.0206

0.91

0.442
0.463
0.421
0.338

1.664

Qi

69
81
65
24
239

Pi

0.0206
0.0206
0.0206
0.0206

0.192
0.125
0.38
0.213

Qi

85
89
81
65
320

0.0206
0.0206
0.0206
0.0206

T.C.P

Qi

37
24
73
41
175

0.359
0.421
0.338
0.125

1.243

Qi

49
81
85
77
292

Pi

0.255
0.421
0.442
0.4

1.518

Qi

81
65
57
37
240

0.421
0.338
0.296
0.192

1.247

nudo

Manzana
A
B
D
H1
OTROS

N viviendas
7
3
8
9
6

Dens.(hab/viv.)
2.88
2.88
2.88
2.88
2.88

33

T.C.P

Pi

0.0206
0.0206
0.0206
0.0206
0.0206

Qi

28
12
33
37
24
134

0.146
0.062
0.172
0.192
0.125

0.697

VERIFICADOR DE CIRCUITOS CERRADOS PARA REDES DE AGUA POTABLE METODO DE HARDY C


CIRCUITO I
NUDO

LADO

1
2
3
4

(PULG)

Q0

1-2
2-3
3-4
4-1

2.5
0.84
-0.4
-1.37

LONG(m)

3
1.5
1
2

166.41
209.28
167.77
209.25

V (m/s)

140
140
140
140

0.55
0.74
0.79
0.68

CIRCUITO II
NUDO

LADO

1
4
5
6

(PULG)

Q0

1-4
4-5
5-6
6-1

1.37
-0.55
-1.8
-2.5

LONG(m)

2
1
2
3

209.25
179.34
209.21
178.92

V (m/s)

140
140
140
140

0.68
1.09
0.89
0.55

ITERACIONES
N01

CIRCUITO I

NUDO

LADO

1
2
3
4

Q0

1-2
2-3
3-4
4-1

2.5872
0.9272
-0.3128
-1.5818

N01

LONG(m)

3
1.5
1
2

166.41
209.28
167.77
209.25

V (m/s)

140
140
140
140

0.57
0.81
0.62
0.78

CIRCUITO II

NUDO

LADO

1
4
5
6

1-4
4-5
5-6
6-1

Q0

(PULG)

1.5818
-0.251
-1.501
-2.201

N02

LONG(m)

2
1
2
3

209.25
179.34
209.21
178.92

V (m/s)

140
140
140
140

0.78
0.50
0.74
0.48

CIRCUITO I

NUDO

1-2
2-3
3-4
4-1

(PULG)

LADO

1-2
2-3
3-4
4-1

Q0

(PULG)

2.621
0.961
-0.279
-1.6593

N02

LONG(m)

3
1.5
1
2

166.41
209.28
167.77
209.25

V (m/s)

140
140
140
140

0.57
0.84
0.55
0.82

CIRCUITO II

NUDO

LADO

1 1-4
4 4-5
5 5-6

Q0

1.6593
-0.1397
-1.3897

(PULG)

LONG(m)

2
1
2

209.25
179.34
209.21

V (m/s)

140
140
140

0.82
0.28
0.69

6 6-1

-2.0897

N03

178.92

140

0.46

CIRCUITO I

NUDO

LADO

R
A
1
2
3
4

(PULG)

Q0

R-A
A-1
1-2
2-3
3-4
4-1

7.28
6.37
2.6341
0.9741
-0.2659
-1.6743

N03

LONG(m)

6
6
3
3
2
3

515.09
150.40
166.41
209.28
167.77
209.25

V (m/s)

140
140
140
140
140
140

0.40
0.35
0.58
0.21
0.13
0.37

CIRCUITO II

NUDO

LADO

1
4
5
6

Q0

1-4
4-5
5-6
6-1

1.6743
-0.1116
-1.3616
-2.0616

(PULG)

LONG(m)

3
2
3
3

209.25
179.34
209.21
178.92

V (m/s)

140
140
140
140

0.4
0.1
0.3
0.5

NOTA: Segn OPS/CEPIS/05.145

La presin en cualquier punto de la red no ser menor a 10 m.c.a ni mayor a 50 m.c.a


La velocidad mnima en ningn caso ser menor de 0.3 m/s y deber garantizar la autolimpieza del sistema. En gen
Por otro lado, la velocidad mxima en la red de distribucin no exceder los 2 m/s.
A fin de que no se produzcan prdidas de carga excesivas, puede aplicarse la frmula de Mougnie para la determin
frmula aplicable a presiones a la red de distribucin de 20 a 50 m.c.a est dada por:

V=1.5*(D+0.05)0.5
Donde:
V= Velocidad (m/s)
D= Dimetro de la tubera (m)

AREA DE PRESION N 01
1.- METODO DE SECCIONAMIENTO PARA REDES ABIERTAS
Este mtodo consiste en formar anillos o circuitos, los cuales se numeran por tramos; en cada circuito se efecta un corte o seccio
y se calculan los gastos por cada tramo de la red abierta. Para un seccionamiento ideal, las presiones en los puntos de corte debe
tolerndose una diferencia mxima de 10% con respecto al valor de las presiones obtenidas para cada nudo. Si esto no se compr
alterar convenientemente el dimetro de algunas tuberias o modificar el seccionamiento adoptado.
Las redes se calculan para una capacidad de distribucin igual al consumo mximo horario, el que puede considerarse uniformem
distribuido a lo largo de toda la tubera, o por reas segn la densidad de poblacin.
GASTO EN MARCHA (Qm)
Qm=Qunit x L
DONDE:
Qm=
Gasto en marcha en l/s
Qunit.=
Gasto unitario en l/s
L=
Longitud del tramo en metros
GASTO UNITARIO
Qunit.=Qmh/Long. Total real
(no incluye lnea de aduccin)
DONDE:
Qmh=
Gasto mximo horario en l/s
Ltotal=
Longitud Total real en metros
GASTO INICIAL
Qi= Qm + Qf

DONDE:
Qi= Gasto inicial en l/s
Qm= Gasto en marcha en l/s
Qf= Gasto final en l/s
VERIFICADOR DE SISTEMAS ABIERTOS NUDO "F"
TRAMO
LONG.
GASTO(l/s)
(m)
inicial
Marcha
Final
Qi
Qm
Qf

F-F1
63.84
1.028

1.028
F1-F2
85.3
0.1322
0.1322
0.000
F1-F3
61.45
0.0952
0.0952
0.000
F1-F4
66.5
0.7826
0.1031
0.680
F4-F5
77.42
0.1200
0.1200
0.000
F4-F6
53.6
0.1582
0.0831
0.075
F6-F7
48.46
0.0751
0.0751
0.000
F4-F8
77.68
0.4014
0.1204
0.281
F8-F9
76.84
0.2000
0.1191
0.081
F9-F10
52.23
0.0809
0.0809
0.000
L=
663.32 m

Ficticio
Qfic

1.028
0.066
0.048
0.731
0.060
0.117
0.038
0.341
0.140
0.040

D
PULG

2
2
2
2
2
2
2
2
2
2

Qi= 0.00154978 l/s/m

VERIFICADOR DE SISTEMAS ABIERTOS NUDO "E"


TRAMO
LONG.
GASTO(l/s)
(m)
inicial
Marcha
Final
Qi
Qm
Qf

E-E1
75
0.669

0.669
E1-E2
55.23
0.0634
0.0634
0.000
E1-E3
84.96
0.5196
0.0975
0.422
E3-E4
92.6
0.1062
0.1062
0.000
E3-E5
80.71
0.1493
0.0926
0.057
E5-E6
49.43
0.0567
0.0567
0.000
E3-E7
74
0.1665
0.0849
0.082
E7-E8
71.16
0.0816
0.0816
0.000

L=

Ficticio
Qfic

0.669
0.032
0.471
0.053
0.103
0.028
0.124
0.041

D
PULG

2
2
2
2
2
2
2
2

583.09 m

Qi= 0.00114734 l/s/m


VERIFICADOR DE SISTEMAS ABIERTOS NUDO "X"
TRAMO
LONG.
GASTO(l/s)
(m)
inicial
Marcha
Final
Qi
Qm
Qf

X-X1
6.3
0.680

0.680
X1-X2
88.16
0.6681
0.1664
0.502
X2-X3
70.33
0.1328
0.1328
0.000
X2-X4
65.14
0.3689
0.1230
0.246
X4-X5
60.3
0.1138
0.1138
0.000
X4-X6
70
0.1321
0.1321
0.000
L=
360.23 m

Ficticio
Qfic

0.680
0.585
0.066
0.307
0.057
0.066

D
PULG

2
2
2
2
2
2

Qi= 0.00188768 l/s/m


VERIFICADOR DE SISTEMAS ABIERTOS NUDO "A"
TRAMO
LONG.
GASTO(l/s)

(m)

A-A1
A1-A2
A2-A3
A2-A4
A4-A5
A1-A6
A1-A7
A7-A8
L=

83.2
71.9
20.3
68.3
46.6
62.58
70.76
61.54
485.18 m

inicial
Qi

1.8900
0.8068
0.0791
0.4476
0.1815
0.2438
0.5154
0.2397

Marcha
Qm

0.2801
0.0791
0.2661
0.1815
0.2438
0.2756
0.2397

Final
Qf

1.890
0.527
0.000
0.182
0.000
0.000
0.240
0.000

Ficticio
Qfic

1.890
0.667
0.040
0.315
0.091
0.122
0.378
0.120

PULG

2
2
2
2
2
2
2
2

Qi= 0.00389546 l/s/m


VERIFICADOR DE SISTEMAS ABIERTOS NUDO "D"
TRAMO
LONG.
GASTO(l/s)
(m)
inicial
Marcha
Final
Qi
Qm
Qf

D-D1
153.9
0.1000

0.100
D1-D2
70.86
0.0464
0.0247
0.022
D2-D3
62.47
0.0217
0.0217
0.000
L=
287.23 m

Ficticio
Qfic

0.100
0.034
0.011

D
PULG

2
2
2

Qi= 0.00034815 l/s/m


VERIFICADOR DE SISTEMAS ABIERTOS NUDO "B"
TRAMO
LONG.
GASTO(l/s)
(m)
inicial
Marcha
Final
Qi
Qm
Qf

B-B1
70.28
0.2220

0.222
B1-B2
49.05
0.2220
0.2220
0.000
L=
119.33 m
0.0019
B-B3
B3-B4
L=

65.66
61.92
127.58 m

0.1000
0.1000

0.0515
0.0485

0.100
0.000

Ficticio
Qfic

0.222
0.111

D
PULG

2
2

0.100
0.050

2
2

Qi= 0.00078382 l/s/m


VERIFICADOR DE SISTEMAS ABIERTOS NUDO "C"
TRAMO
LONG.
GASTO(l/s)
(m)
inicial
Marcha
Final
Qi
Qm
Qf

C-C1
153.9
0.1000

0.100
C1-C2
70.86
0.1000
0.1000
0.000
L=
224.76 m

Ficticio
Qfic

0.100
0.050

D
PULG

2
2

Qi= 0.00044492 l/s/m

NOTA: Segn OPS/CEPIS/05.145

La presin en cualquier punto de la red no ser menor a 10 m.c.a ni mayor a 50 m.c.a


La velocidad mnima en ningn caso ser menor de 0.3 m/s y deber garantizar la autolimpieza del sistema. En gen

Por otro lado, la velocidad mxima en la red de distribucin no exceder los 2 m/s.
A fin de que no se produzcan prdidas de carga excesivas, puede aplicarse la frmula de Mougnie para la determin
frmula aplicable a presiones a la red de distribucin de 20 a 50 m.c.a est dada por:

V=1.5*(D+0.05)0.5
Donde:
V= Velocidad (m/s)
D= Dimetro de la tubera (m)

VERIFICADOR DE CIRCUITOS CERRADOS PARA REDES DE AGUA POTABLE METODO DE HARDY C


CIRCUITO III
NUDO

LADO

1
2
3
4

NUDO

LADO

R
A
1
2
3
4

nudo

Dens.(hab/viv.)
2.88

Manzana
N viviendas
J1'
10
J1
9

Dens.(hab/viv.)
2.88
2.88

19

N viviendas
5
6

Dens.(hab/viv.)
2.88
2.88

11

N viviendas
4

Dens.(hab/viv.)
2.88

C
G1

nudo

Manzana

28.3
166.17
104.84
133.08

LONG(m)

N viviendas
9

Manzana

(PULG)

6
2
2
2
2
2

J1

nudo

LONG(m)

3
2
2
2

7.28
0.91
0.5469
0.1409
-0.0881
-0.3631

Manzana

0.455
0.049
-0.18
-0.455

Q0

R-A
A-1
1-2
2-3
3-4
4-1

nudo

(PULG)

Q0

1-2
2-3
3-4
4-1

515.09
4.88
28.3
166.17
104.84
133.08

T.C.P

0.0206

0.40
0.45
0.27
0.07
0.05
0.18

Qi

37
37

Pi

0.192

0.192

Qi

41
37
78

Pi

0.0206
0.0206

T.C.P

V (m/s)

Pi

0.0206
0.0206

T.C.P

0.10
0.02
0.09
0.22

140
140
140
140
140
140

0.0206

T.C.P

V (m/s)

140
140
140
140

0.213
0.192

0.405

Qi

20
24
44

Pi

0.104
0.125

0.229

Qi

16
16

0.083

0.083

DATOS HIDRAULICOS
NUDO

LADO

R
A
1
2
3
4

R-A
A-1
1-2
2-3
3-4
4-1

Q0

7.28
0.91
0.5469
0.1409
-0.0881
-0.3631

CALCULOS

(PULG)

LONG(m)

6
2
2
2
2
2

515.09
4.88
28.3
166.17
104.84
133.08

V (m/s)

140
140
140
140
140
140

0.40
0.45
0.27
0.07
0.05
0.18

ESION N 01

S DE AGUA POTABLE METODO DE HARDY CROSS


hf

0.7894
3.8534
-5.6332
-2.348

hf

2.348
-10.8601
-3.8918
-0.8488

hf/Q0

0.5842
8.4867
26.0536
3.1707

hf/Q0

3.1707
36.5294
3.9999
0.6281

0.08718
0.08718
0.08718
-0.21179

0.21179
0.29897
0.29897
0.29897

Q'

2.5872
0.9272
-0.3128
-1.5818

Q'

1.5818
-0.251
-1.501
-2.201

ONES
hf

0.8412
4.6267
-3.5726
-3.0641

hf

3.0641
-2.5405
-2.78
-0.6704

hf

0.8616
4.9439
-2.8908
-3.3479

hf

3.3479
-0.8584
-2.4104

hf/Q0

0.6015
9.2314
21.1295
3.5836

hf/Q0

3.5836
18.7248
3.4264
0.5635

hf/Q0

0.6081
9.5174
19.1684
3.7327

hf/Q0

3.7327
11.3675
3.2088

0.03383
0.03383
0.03383
-0.07746

Q'

2.621
0.961
-0.279
-1.6593

Q'

0.07746
0.11129
0.11129
0.11129

1.6593
-0.1397
-1.3897
-2.0897

Q'

0.01312
0.01312
0.01312
-0.01499

2.6341
0.9741
-0.2659
-1.6743

Q'

0.01499
0.02811
0.02811

1.6743
-0.1116
-1.3616

-0.609

0.5391

0.02811

-2.0616

Segn
Mouqnie
V(m/s)

COTA PIEZOMETRICA
hf

0.7
0.7
0.5
0.5
0.5
0.5

0.6125
0.1397
0.8796
0.1756
-0.0917
-0.4783

hf/Q0

0.6107
9.6277
18.3991
3.7614

0.00339
0.00339
0.00339
-0.00118

Q'

2.638
0.978
-0.263
-1.676

Segn
Mouqnie
V(m/s)

189.00
188.39
188.25
187.37
187.19
187.28

FINAL

188.39
188.25
187.37
187.19
187.28
187.76

COTA PIEZOMETRICA
hf

0.5
0.5
0.5
0.5

INICIAL

0.4783
-0.0197
-0.3262
-0.6010

hf/Q0

3.7614
9.3876
3.1534
0.5329

0.00118
0.00457
0.00457
0.00457

Q'

1.676
-0.107
-1.357
-2.057

INICIAL

188.25
187.77
187.79
188.12

mayor a 50 m.c.a
garantizar la autolimpieza del sistema. En general se recomienda un rango de velocidades de 0.5 - 1 m/s.
der los 2 m/s.
plicarse la frmula de Mougnie para la determinacin de las velocidades ideales para cada dimetro. Dicha

SION N 01

os; en cada circuito se efecta un corte o seccionamiento


ideal, las presiones en los puntos de corte deben ser iguales
obtenidas para cada nudo. Si esto no se comprueba. Se deber

o horario, el que puede considerarse uniformemente

FINAL

187.77
187.79
188.12
188.72

V
(m/seg)

0.507
0.033
0.023
0.361
0.030
0.058
0.019
0.168
0.069
0.020

V
(m/seg)

0.330
0.016
0.232
0.026
0.051
0.014
0.061
0.020

V
(m/seg)

0.335
0.289
0.033
0.152
0.028
0.033

V
(m/seg)

hf
()

Hf
(m)

Mougnie
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48

0.426
0.004
0.001
0.236
0.003
0.006
0.001
0.067
0.013
0.001

V
(m/seg)

hf
()

Hf
(m)

Mougnie
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48

0.226
0.001
0.134
0.003
0.008
0.000
0.010
0.001

V
(m/seg)

hf
()

Hf
(m)

Mougnie
0.48
0.48
0.48
0.48
0.48
0.48

6.667
0.042
0.023
3.548
0.035
0.119
0.015
0.866
0.168
0.017

3.011
0.011
1.572
0.028
0.095
0.009
0.133
0.017

3.104
2.349
0.042
0.715
0.032
0.042

hf

COTA PIEZOMETRICA
Inicial
Final
(i)
(f)

2975.490
2975.064
2975.064
2975.061
2975.061
2975.059
2975.059
2974.823
2974.823
2974.820
2974.820
2974.814
2974.814
2974.813
2974.813
2974.746
2974.746
2974.733
2974.733
2974.732

COTA TERRENO
Inicial
(i)

2975.490
2932.500
2932.500
2932.500
2931.000
2931.000
2923.000
2931.000
2930.000
2918.250

COTA PIEZOMETRICA
Inicial
Final
(i)
(f)

2975.810
2975.584
2975.584
2975.583
2975.583
2975.450
2975.450
2975.447
2975.447
2975.440
2975.440
2975.439
2975.439
2975.429
2975.429
2975.428

COTA TERRENO
Inicial
(i)

2947.000
2939.500
2939.500
2938.680
2938.680
2943.000
2938.680
2936.500

0.020
0.207
0.003
0.047
0.002
0.003

COTA PIEZOMETRICA
Inicial
Final
(i)
(f)

2978.430
2978.410
2978.410
2978.203
2978.203
2978.200
2978.200
2978.153
2978.153
2978.152
2978.152
2978.149

COTA TERRENO
Inicial
(i)

2958.500
2958.500
2950.500
2950.500
2941.000
2941.000

Hf

COTA PIEZOMETRICA

COTA TERRENO

(m/seg)

()

(m)

Mougnie
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48

20.567
2.992
0.016
0.746
0.075
0.129
1.045
0.125

1.711
0.215
0.000
0.051
0.004
0.008
0.074
0.008

V
(m/seg)

hf
()

Hf
(m)

Mougnie
0.48
0.48
0.48

0.014
0.001
0.000

V
(m/seg)

hf
()

Hf
(m)

0.110
0.055

Mougnie
0.48
0.48

0.391
0.109

0.028
0.005

0.049
0.025

0.48
0.48

0.089
0.025

0.006
0.002

(m/seg)

0.932
0.329
0.020
0.155
0.045
0.060
0.186
0.059

V
(m/seg)

0.049
0.017
0.005

V
(m/seg)

V
(m/seg)

0.049
0.025

0.089
0.012
0.001

V
(m/seg)

hf
()

Hf
(m)

Mougnie
0.48
0.48

0.014
0.002

0.089
0.025

Inicial
(i)

2977.300
2975.589
2975.374
2975.374
2975.323
2975.319
2975.311
2975.237

Final
(f)

2975.589
2975.374
2975.374
2975.323
2975.319
2975.311
2975.237
2975.230

Inicial
(i)

2964.000
2950.500
2952.500
2952.500
2938.000
2950.500
2950.500
2943.000

COTA PIEZOMETRICA
Inicial
Final
(i)
(f)

2976.600
2976.586
2976.586
2976.585
2976.585
2976.585

COTA TERRENO
Inicial
(i)

2947.500
2938.500
2929.500

COTA PIEZOMETRICA
Inicial
Final
(i)
(f)

2976.110
2976.083
2976.083
2976.078

COTA TERRENO
Inicial
(i)

2938.750
2933.000

2976.110
2976.104

2976.104
2976.103

COTA PIEZOMETRICA
Inicial
Final
(i)
(f)

2975.910
2975.896
2975.896
2975.894

mayor a 50 m.c.a
garantizar la autolimpieza del sistema. En general se recomienda un rango de velocidades de 0.5 - 1 m/s.

2938.750
2937.500

COTA TERRENO
Inicial
(i)

2935.000
2934.500

der los 2 m/s.


plicarse la frmula de Mougnie para la determinacin de las velocidades ideales para cada dimetro. Dicha

S DE AGUA POTABLE METODO DE HARDY CROSS


hf

1.2063
0.4639
-3.2574
-5.6724

hf/Q0

4.9047
17.5146
33.4788
23.0636

Q'

0.09194
0.09194
0.09194
0.09194

0.5469
0.1409
-0.0881
-0.3631

Q'

COTA PIEZOMETRICA
hf

0.61
0.0260
0.0587
0.0280
-0.0074
-0.1294

hf/Q0

5.7367
43.0713
18.2144
19.0309

-0.00434
-0.00434
-0.00434
-0.00434

0.5426
0.1366
-0.0924
-0.3674

INICIAL

189.00
188.39
188.36
188.30
188.27
188.28

FINAL

188.39
188.36
188.30
188.27
188.28
188.41

COTA DE TERRENO
INICIAL

189.00
170.15
170.25
172.00
165.69
164.00

CALCULOS
hf

0.61
0.0260
0.0587
0.0280
-0.0074
-0.1294

COTA PIEZOMETRICA
INICIAL

189.00
188.39
188.36
188.30
188.27
188.28

FINAL

188.39
188.36
188.30
188.27
188.28
188.41

COTA DE TERRENO
INICIAL

189.00
170.15
170.25
172.00
165.69
164.00

FINAL

170.15
170.25
172.00
165.69
164.00
170.25

PRESIONES
INICIAL

0.00
18.24
18.11
16.30
22.58
24.28

FINAL

18.24
18.11
16.30
22.58
24.28
18.16

COTA DE TERRENO
INICIAL

189.00
170.15
162.64
164.39
154.92
154.50

FINAL

170.15
162.64
164.39
154.92
154.50
162.64

COTA DE TERRENO
INICIAL

162.64
154.50
155.69
164.73

FINAL

154.50
155.69
164.73
162.64

PRESIONES
INICIAL

FINAL

0.00
18.24
25.61
22.98
32.27
32.79

18.24
25.61
22.98
32.27
32.79
25.12

PRESIONES
INICIAL

25.61
33.27
32.10
23.39

FINAL

33.27
32.10
23.39
26.08

COTA TERRENO
Final
(f)

2932.500
2926.000
2930.000
2931.000
2920.000
2923.000
2925.000
2930.000
2918.250
2915.500

PRESIONES
Inicial
Final
(i)
(f)

39.240
42.564
42.564
49.061
42.561
45.059
42.559
43.823
43.823
54.820
43.820
51.814
51.814
49.813
43.813
44.746
44.746
56.483
56.483
59.232

COTA TERRENO
Final
(f)

2939.500
2943.000
2938.680
2929.000
2943.000
2935.000
2936.500
2935.500

PRESIONES
Inicial
Final
(i)
(f)

28.810
36.084
36.084
32.583
36.083
36.770
36.770
46.447
36.767
32.440
32.440
40.439
36.759
38.929
38.929
39.928

COTA TERRENO
Final
(f)

2958.500
2950.500
2944.000
2941.000
2939.000
2938.000

PRESIONES
Inicial
Final
(i)
(f)

19.920
19.910
19.910
27.703
27.703
34.200
27.700
37.153
37.153
39.151
37.151
40.149

COTA TERRENO

PRESIONES

Final
(f)

2950.500
2952.500
2953.000
2938.000
2943.000
2951.500
2943.000
2941.000

Inicial
(i)

13.300
25.089
22.874
22.874
37.323
24.819
24.811
32.237

Final
(f)

25.089
22.874
22.374
37.323
32.319
23.811
32.237
34.229

COTA TERRENO
Final
(f)

2938.500
2929.500
2934.000

PRESIONES
Inicial
Final
(i)
(f)

29.100
38.086
38.086
47.085
47.085
42.585

COTA TERRENO
Final
(f)

2933.000
2934.500

PRESIONES
Inicial
Final
(i)
(f)

37.360
43.083
43.083
41.578

2937.500
2935.000

COTA TERRENO
Final
(f)

2934.500
2932.300

37.360
38.604

38.604
41.103

PRESIONES
Inicial
Final
(i)
(f)

40.910
41.396
41.396
43.594

COTA DE TERRENO
FINAL

170.15
170.25
172.00
165.69
164.00
170.25

PRESIONES
INICIAL

0.00
18.24
18.11
16.30
22.58
24.28

FINAL

18.24
18.11
16.30
22.58
24.28
18.16

DATOS HIDRAULICOS
NUDO

LADO

R
A
1
2
3
4

Q0

R-A
A-1
1-2
2-3
3-4
4-1

(PULG)

7.28
6.37
2.6341
0.9741
-0.2659
-1.6743

6
6
3
3
2
3

DATOS HIDRAULICOS
NUDO

LADO

1
4
5
6

Q0

1-4
4-5
5-6
6-1

1.6743
-0.1116
-1.3616
-2.0616

(PULG)

3
2
3
3

DATOS HIDRAULICOS
NUDO

LADO

R
A
1
2
3
4

R-A
A-1
1-2
2-3
3-4
4-1

Q0

7.28
0.91
0.5469
0.1409
-0.0881
-0.3631

(PULG)

LONG(m)

6
2
3
3
2
2

515.09
4.88
28.3
166.17
104.84
133.08

140
140
140
140
140
140

S HIDRAULICOS

DATOS CALCULADOS
LONG(m)

515.09
150.40
166.41
209.28
167.77
209.25

V (m/s)

140
140
140
140
140
140

S HIDRAULICOS

V(m/s)

0.40
0.35
0.58
0.21
0.13
0.37

0.7
0.7
0.5
0.5
0.5
0.5
Mouqnie

COTA PIEZOMETRICA
hf

0.6125
0.1397
0.8796
0.1756
-0.0917
-0.4783

DATOS CALCULADOS
LONG(m)

209.25
179.34
209.21
178.92

V (m/s)

140
140
140
140

V(m/s)

0.4
0.1
0.3
0.5

0.5
0.5
0.5
0.5
Mouqnie

INICIAL

189.00
188.39
188.25
187.37
187.19
187.28

FINAL

188.39
188.25
187.37
187.19
187.28
187.76

COTA PIEZOMETRICA
hf

0.4783
-0.0197
-0.3262
-0.6010

INICIAL

188.25
187.77
187.79
188.12

FINAL

187.77
187.79
188.12
188.72

DATOS CALCULADOS
V (m/s)

0.40
0.45
0.12
0.03
0.05
0.18

hf

0.61
0.0260
0.0082
0.0039
-0.0074
-0.1294

COTA PIEZOMETRICA
INICIAL

189.00
188.39
188.36
188.35
188.35
188.36

FINAL

188.39
188.36
188.35
188.35
188.36
188.49

COTA DE TERRENO
INICIAL

189.00
170.15
170.25
172.00
165.69
164.00

FINAL

170.15
170.25
172.00
165.69
164.00
170.25

PRESIONES
INICIAL

0.00
18.24
18.11
16.35
22.66
24.36

COTA DE TERRENO
INICIAL

189.00
170.15
162.64
164.39
154.92
154.50

FINAL

170.15
162.64
164.39
154.92
154.50
162.64

COTA DE TERRENO
INICIAL

162.64
154.50
155.69
164.73

FINAL

154.50
155.69
164.73
162.64

PRESIONES
INICIAL

FINAL

0.00
18.24
25.61
22.98
32.27
32.79

18.24
25.61
22.98
32.27
32.79
25.12

PRESIONES
INICIAL

25.61
33.27
32.10
23.39

FINAL

33.27
32.10
23.39
26.08

PRESIONES
FINAL

18.24
18.11
16.35
22.66
24.36
18.24

AREA DE PRESION N 02
1.- METODO DE SECCIONAMIENTO PARA REDES ABIERTAS
Este mtodo consiste en formar anillos o circuitos, los cuales se numeran por tramos; en cada circuito se efecta un corte o se
y se calculan los gastos por cada tramo de la red abierta. Para un seccionamiento ideal, las presiones en los puntos de corte de
tolerndose una diferencia mxima de 10% con respecto al valor de las presiones obtenidas para cada nudo. Si esto no se com
alterar convenientemente el dimetro de algunas tuberias o modificar el seccionamiento adoptado.
Las redes se calculan para una capacidad de distribucin igual al consumo mximo horario, el que puede considerarse uniform
distribuido a lo largo de toda la tubera, o por reas segn la densidad de poblacin.
GASTO EN MARCHA (Qm)
Qm=Qunit x L
DONDE:
Qm=
Gasto en marcha en l/s
Qunit.=
Gasto unitario en l/s
L=
Longitud del tramo en metros
GASTO UNITARIO
Qunit.=Qmh/Long. Total real
(no incluye lnea de aduccin)
DONDE:
Qmh=
Gasto mximo horario en l/s
Ltotal=
Longitud Total real en metros
GASTO INICIAL
Qi= Qm + Qf
DONDE:
Qi= Gasto inicial en l/s
Qm= Gasto en marcha en l/s
Qf= Gasto final en l/s
TRAMO

R-1
1-2
1-3
3-4
3-5
5-6
5-7
7-8
7-9
9-10
9-11
11-12
11-13
13-14
13-15
15-16
15-17
17-18
17-19
18-20
19-21
LT=

LONG.
(m)

351.62
156.78
61.75
164.23
60.02
180.75
59.73
178.14
60.41
167.86
60.12
149
47.32
136.9
69.4
98.56
174.6
7.67
9.64
261.16
750.79
2854.83 m

inicial
Qi

4.580
0.2515
4.3285
0.2635
3.9659
0.2900
3.5797
0.2858
3.1981
0.2693
2.8318
0.2390
2.4964
0.2196
2.2008
0.1581
1.9314
0.4313
1.2200
0.4190
1.2045

GASTO(l/s)
Marcha
Final
Ficticio
Qm
Qf
Qfic

4.580
4.580
0.2515
0.000
0.126
0.0991
4.229
4.279
0.2635
0.000
0.132
0.0963
3.870
3.918
0.2900
0.000
0.145
0.0958
3.484
3.532
0.2858
0.000
0.143
0.0969
3.101
3.150
0.2693
0.000
0.135
0.0965
2.735
2.784
0.2390
0.000
0.120
0.0759
2.420
2.458
0.2196
0.000
0.110
0.1113
2.089
2.145
0.1581
0.000
0.079
0.2801
1.651
1.791
0.0123
0.419
0.425
0.0155
1.204
1.212
0.4190
0.000
0.209
1.2045
0.000
0.602
(NO INCLUYE LINEA DE ADUCCION)

D
PULG

4
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
2.5
1
2
0.75
1.5

V
(m/seg)
Segn
Mougnie
0.6
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.4
0.5
0.4
0.4

Qi=

0.0016043 l/s/m

CHEQUEO DE PRESIONES EN LOS PUNTOS DE SECCIONAMIENTO


PUNTOS
SECCIONADOS

PRESION CALCULADA (m)


Mxima
Mnima

14.280

13.870

VALOR
MEDIO (m)

14.075

MAXIMAPORCENTAJE
(m)
DEL VALOR
cumple
DIFERENCIA MEDIO (%)
<10%

0.410

2.91

Ok

NOTA: Segn OPS/CEPIS/05.145


La presin en cualquier punto de la red no ser menor a 10 m.c.a ni mayor a 50 m.c.a
La velocidad mnima en ningn caso ser menor de 0.3 m/s y deber garantizar la autolimpieza del sistema. En g
Por otro lado, la velocidad mxima en la red de distribucin no exceder los 2 m/s.
A fin de que no se produzcan prdidas de carga excesivas, puede aplicarse la frmula de Mougnie para la deter
frmula aplicable a presiones a la red de distribucin de 20 a 50 m.c.a est dada por:

V=1.5*(D+0.05)0.5
Donde:
V= Velocidad (m/s)
D= Dimetro de la tubera (m)

TRAMO

R-1
1-2
1-3
3-4
3-5
5-6

LONG.
(m)

351.62
156.78
61.75
164.23
60.02
180.75

inicial
Qi

4.580
0.2515
4.3285
0.2635
3.9659
0.2900

GASTO(l/s)
Marcha
Final
Qm
Qf

4.580
0.2515
0.000
0.0991
4.229
0.2635
0.000
0.0963
3.870
0.2900
0.000

Ficticio
Qfic

4.580
0.126
4.279
0.132
3.918
0.145

D
PULG

4
2
3
2
3
2

V
(m/seg)
Segn
Mougnie
0.6
0.5
0.5
0.5
0.5
0.5

5-7
7-8
7-9
9-10
9-11
11-12
11-13
13-14
13-15
15-16
15-17
17-18
17-19
18-20
19-21

59.73
178.14
60.41
167.86
60.12
149
47.32
136.9
69.4
98.56
174.6
7.67
9.64
261.16
750.79

3.5797
0.2858
3.1981
0.2693
2.8318
0.2390
2.4964
0.2196
2.2008
0.1581
1.9314
0.4313
1.2200
0.4190
1.2045

0.0958
0.2858
0.0969
0.2693
0.0965
0.2390
0.0759
0.2196
0.1113
0.1581
0.2801
0.0123
0.0155
0.4190
1.2045

3.484
0.000
3.101
0.000
2.735
0.000
2.420
0.000
2.089
0.000
1.651
0.419
1.204
0.000
0.000

3.532
0.143
3.150
0.135
2.784
0.120
2.458
0.110
2.145
0.079
1.791
0.425
1.212
0.209
0.602

3
2
3
2
3
2
3
2
3
2
2.5
1
2
0.75
1.5

0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.4
0.5
0.4
0.4

se efecta un corte o seccionamiento


en los puntos de corte deben ser iguales
a nudo. Si esto no se comprueba. Se deber

ede considerarse uniformemente

hf
()

Hf
(m)

3.6280
0.1367
12.9696
0.1490
11.0174
0.1779
9.0936
0.1732
7.3574
0.1551
5.8544
0.1244
4.6522
0.1064
3.6153
0.0579
6.2888
37.9449
9.0438
41.5360
10.0507

1.2757
0.0214
0.8009
0.0245
0.6613
0.0322
0.5432
0.0309
0.4445
0.0260
0.3520
0.0185
0.2201
0.0146
0.2509
0.0057
1.0980
0.2910
0.0872
10.8476
7.5460

COTA PIEZOMETRICA
Inicial
Final
(i)
(f)

171.500
170.224
170.224
170.203
170.224
169.423
169.423
169.399
169.423
168.762
168.762
168.730
168.762
168.219
168.219
168.188
168.219
167.774
167.774
167.748
167.774
167.422
167.422
167.404
167.422
167.202
167.202
167.187
167.202
166.951
166.951
166.945
166.951
165.853
165.853
165.562
165.853
165.766
165.562
154.715
165.766
158.220

COTA TERRENO
Inicial
Final
(i)
(f)

171.500
155.162
155.162
146.902
155.162
154.161
154.161
146.920
154.161
154.203
154.203
147.050
154.203
153.969
153.969
147.130
153.969
154.303
154.303
147.000
154.303
154.410
154.410
147.323
154.410
153.986
153.986
150.360
153.986
152.572
152.572
152.000
152.572
147.982
147.982
148.382
147.982
147.397
148.382
135.000
147.397
148.000

PRESIONES
Inicial
Final
(i)
(f)

0.00
15.06
15.06
23.30
15.06
15.26
15.26
22.48
15.26
14.56
14.56
21.68
14.56
14.25
14.25
21.06
14.25
13.47
13.47
20.75
13.47
13.01
13.01
20.08
13.01
13.22
13.22
16.83
13.22
14.38
14.38
14.95
14.38
17.87
17.87
17.18
17.87
18.37
17.18
19.71
18.37
10.22

0.44897125

0.91

impieza del sistema. En general se recomienda un rango de velocidades de 0.5 - 1 m/s.

e Mougnie para la determinacin de las velocidades ideales para cada dimetro. Dicha

hf
()

Hf
(m)

3.6280
0.1367
12.9696
0.1490
11.0174
0.1779

1.2757
0.0214
0.8009
0.0245
0.6613
0.0322

COTA PIEZOMETRICA
Inicial
Final
(i)
(f)

171.500
170.224
170.224
170.203
170.224
169.423
169.423
169.399
169.423
168.762
168.762
168.730

COTA TERRENO
Inicial
Final
(i)
(f)

171.500
155.162
155.162
146.902
155.162
154.161
154.161
146.920
154.161
154.203
154.203
147.050

PRESIONES
Inicial
Final
(i)
(f)

0.00
15.06
15.06
23.30
15.06
15.26
15.26
22.48
15.26
14.56
14.56
21.68

9.0936
0.1732
7.3574
0.1551
5.8544
0.1244
4.6522
0.1064
3.6153
0.0579
6.2888
37.9449
9.0438
41.5360
10.0507

0.5432
0.0309
0.4445
0.0260
0.3520
0.0185
0.2201
0.0146
0.2509
0.0057
1.0980
0.2910
0.0872
10.8476
7.5460

168.762
168.219
168.219
167.774
167.774
167.422
167.422
167.202
167.202
166.951
166.951
165.853
165.853
165.562
165.766

168.219
168.188
167.774
167.748
167.422
167.404
167.202
167.187
166.951
166.945
165.853
165.562
165.766
154.715
158.220

154.203
153.969
153.969
154.303
154.303
154.410
154.410
153.986
153.986
152.572
152.572
147.982
147.982
148.382
147.397

153.969
147.130
154.303
147.000
154.410
147.323
153.986
150.360
152.572
152.000
147.982
148.382
147.397
135.000
148.000

14.56
14.25
14.25
13.47
13.47
13.01
13.01
13.22
13.22
14.38
14.38
17.87
17.87
17.18
18.37

14.25
21.06
13.47
20.75
13.01
20.08
13.22
16.83
14.38
14.95
17.87
17.18
18.37
19.71
10.22

TRAMO

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

R-1
1-2
1-3
3-4
3-5
5-6
5-7
7-8
7-9
9-10
9-11
11-12
11-13
13-14
13-15
15-16
15-17
17-18
17-19
18-20
19-21

LONG.
(m)

351.62
156.78
61.75
164.23
60.02
180.75
59.73
178.14
60.41
167.86
60.12
149
47.32
136.9
69.4
98.56
174.6
7.67
9.64
261.16
750.79

inicial
Qi

4.580
0.2515
4.3285
0.2635
3.9659
0.2900
3.5797
0.2858
3.1981
0.2693
2.8318
0.2390
2.4964
0.2196
2.2008
0.1581
1.9314
0.4313
1.2200
0.4190
1.2045

VERIFICADOR DE SIST
ARE
GASTO(l/s)
Marcha
Final
Qm
Qf

4.580
0.2515
0.000
0.0991
4.229
0.2635
0.000
0.0963
3.870
0.2900
0.000
0.0958
3.484
0.2858
0.000
0.0969
3.101
0.2693
0.000
0.0965
2.735
0.2390
0.000
0.0759
2.420
0.2196
0.000
0.1113
2.089
0.1581
0.000
0.2801
1.651
0.0123
0.419
0.0155
1.204
0.4190
0.000
1.2045
0.000

VERIFICADOR DE SISTEMA ABIERTOS PARA REDES DE AGUA POTABLE METODO USADO DE SECCIONAMIENTO
AREA DE PRESION N 02, CENTRO POBLADO MENOR SANTA MARIA ALTA
(l/s)
D
V
V
hf
Hf
COTA PIEZOMETRICA
Ficticio
PULG
(m/seg)
(m/seg)
()
(m)
Inicial
Final
Qfic
Segn
(i)
(f)

Mougnie

4.580
4
0.6
0.6
3.6280
1.2757
171.500
170.224
0.126
1
0.2
0.4
3.9861
0.6249
170.224
169.599
4.279
3
0.9
0.5
12.9696
0.8009
170.224
169.423
0.132
1
0.3
0.4
4.3436
0.7133
169.423
168.710
3.918
3
0.9
0.5
11.0174
0.6613
169.423
168.762
0.145
1
0.3
0.4
5.1862
0.9374
168.762
167.824
3.532
3
0.8
0.5
9.0936
0.5432
168.762
168.219
0.143
1
0.3
0.4
5.0486
0.8993
168.219
167.319
3.150
3
0.7
0.5
7.3574
0.4445
168.219
167.774
0.135
1
0.3
0.4
4.5228
0.7592
167.774
167.015
2.784
3
0.6
0.5
5.8544
0.3520
167.774
167.422
0.120
1
0.2
0.4
3.6279
0.5406
167.422
166.882
2.458
3
0.5
0.5
4.6522
0.2201
167.422
167.202
0.110
1
0.2
0.4
3.1017
0.4246
167.202
166.777
2.145
3
0.5
0.5
3.6153
0.2509
167.202
166.951
0.079
0.75
0.3
0.4
6.8469
0.6748
166.951
166.276
1.791
2.5
0.6
0.5
6.2888
1.0980
166.951
165.853
0.425
1
0.8
0.4
37.9449
0.2910
165.853
165.562
1.212
2
0.6
0.5
9.0438
0.0872
165.853
165.766
0.209
0.75
0.7
0.4
41.5360
10.8476
165.562
154.715
0.602
1.5
0.5
0.4
10.0507
7.5460
165.766
158.220

AMIENTO
COTA TERRENO
Inicial
Final
(i)
(f)

171.500
155.162
155.162
146.902
155.162
154.161
154.161
146.920
154.161
154.203
154.203
147.050
154.203
153.969
153.969
147.130
153.969
154.303
154.303
147.000
154.303
154.410
154.410
147.323
154.410
153.986
153.986
150.360
153.986
152.572
152.572
152.000
152.572
147.982
147.982
148.382
147.982
147.397
148.382
135.000
147.397
148.000

PRESIONES
Inicial
Final
(i)
(f)

0.00
15.06
15.06
22.70
15.06
15.26
15.26
21.79
15.26
14.56
14.56
20.77
14.56
14.25
14.25
20.19
14.25
13.47
13.47
20.01
13.47
13.01
13.01
19.56
13.01
13.22
13.22
16.42
13.22
14.38
14.38
14.28
14.38
17.87
17.87
17.18
17.87
18.37
17.18
19.71
18.37
10.22

NOTA: Segn OPS/CEPIS/05.145


La presin en cualquier punto de la red no ser menor a 10 m.c.a ni mayor a 50 m.c.a
La velocidad mnima en ningn caso ser menor de 0.3 m/s y deber garantizar la autolimpieza del sistema. En g
Por otro lado, la velocidad mxima en la red de distribucin no exceder los 2 m/s.
A fin de que no se produzcan prdidas de carga excesivas, puede aplicarse la frmula de Mougnie para la deter
frmula aplicable a presiones a la red de distribucin de 20 a 50 m.c.a est dada por:

impieza del sistema. En general se recomienda un rango de velocidades de 0.5 - 1 m/s.

e Mougnie para la determinacin de las velocidades ideales para cada dimetro. Dicha

Potrebbero piacerti anche