Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
P.D 1185
Fire Code
P.D 957
Subdivision &
Condominium
Law
B.P 220
Economic
Housing
B.P 220
Socialized
Housing
B.P 344
Accessibility
Law
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Occupant Load
Maximum of 90% of
the lot
Maximum of 80% of
the lot
At least 250 mm
thick, 600 mm
below ground
surface
18.6 sq. m/ person
N/A
N/A
N/A
No. of units
Multiplied by 6
N/A
N/A
No. of units
Multiplied by 6
N/A
N/A
N/A
N/A
N/A
N/A
1.10 m
200 mm
250 mm
600 mm
200 mm
250 mm
600 mm
200 mm
250 mm
At least 1 entrance
& 1 exit
N/A
N/A
N/A
Refer to Fire
Code
Specifications
(Too many to
tabulate)
At least 1 entrance
& 1 exit
At least 1 entrance
& 1 exit
At least 1 entrance
& 1 exit
Subject
Residential
Requirements
Corner Lot
Inside Lot
Foundation
Light &
Ventilation
Min. dimension of
court
Passageway from
Inner Court
N/A
N/A
2.00 m
N/A
1.50 m
2.00 m
2.00 m
N/A
At least 1.20 m
N/A
At least 1.20 m
At least 1.20 m
At least 1.20 m
N/A
N/A
N/A
2.40 m
2.40 m
N/A
2.00 m
1.80 m - Mezzanine
2.00 m
1.80 m - Mezzanine
2.00 m
1.80 m - Mezzanine
N/A
P.D 957
Subdivision &
Condominium
Law
B.P 220
Economic
Housing
B.P 220
Socialized
Housing
B.P 344
Accessibility
Law
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
2.25 sq. m
2.00 m
2.30 m
2.30 m
2.13 m
Sum of Areas of
Openings in any
Storey
Window Openings
N/A
Size/ Dimension
of Rooms
P.D 1096
Building Code
P.D 1185
Fire Code
N/A
Eaves over
required windows
N/A
N/A
N/A
N/A
N/A
N/A
Exits
Occupant Load of
less than 10
Occupant Load of
10-499
Occupant load of
500-999
Occupant Load of
1000-above
Distance to exits
without Sprinkle
System
Distance to exits
with Sprinkle
System
Min. exit door
width
Min. exit door
height
Min. corridor
width
Max. slope of
passageway
Dead ends
At least 1 exit
At least 2 exits
At least 1 exit
At least 1 exit
At least 1 exit
N/A
At least 2 exits
N/A
At least 2 exits
N/A
N/A
N/A
At least 3 exits
N/A
At least 3 exits
N/A
N/A
N/A
At least 4 exits
N/A
At least 4 exits
N/A
N/A
N/A
Max. of 45 m
Max. of 46 m
Max. of 45 m
Max. of 45 m
Max. of 45 m
N/A
Max. of 60 m
Max. of 61 m
Max. of 60 m
Max. of 60 m
Max. of 60 m
N/A
700 mm
710 mm
700 mm
800 mm
800 mm
N/A
2.00 m
2.00 m
2.00 m
2.00 m
2.00 m
N/A
1.10 m
550 mm
1.10 m
1.20 m
1.20 m
1.20 m
1:8
N/A
1:8
1:8
1:8
Max. of 6.00 m
Max. of 6.00 m
Max. of 12.00 m
Max. of 12.00 m
Max. of 12.00 m
N/A
Stairways for
Buildings
P.D 1096
Building Code
P.D 1185
Fire Code
P.D 957
Subdivision &
Condominium
Law
B.P 220
Economic
Housing
B.P 220
Socialized
Housing
B.P 344
Accessibility
Law
750 mm
N/A
N/A
N/A
N/A
N/A
900 mm
N/A
900 mm
900 mm
900 mm
N/A
1.10 m
N/A
1.10 m
1.00 m
1.00 m
N/A
200 mm
190 mm class A
200 mm
200 mm
200 mm
N/A
200 mm class B
250 mm class A
230 mm class B
1.12 m
2.75 m class A
3.70 m class B
Tread
250 mm
Min. width
Distance bet.
Landings
1.10 m
3.60 m
Dimension of
Landings in the
direction of travel
Height of
handrails
1.12 m
800-900 mm from
the nosing
760-895 mm
from the nosing
P.D 1096
Building Code
P.D 1185
Fire Code
Min. of width of
sidewalk
1/6 of R.O.W
N/A
Plan Strip
800 mm for
sidewalks exceeding
2.00 m in width
Sidewalks &
Arcades
Driveways,
Entrance & Exits
Slope of entryway
Max. slope of
ramps
Open Space
Requirements
Interior Lots
250 mm
250 mm
250 mm
N/A
1.10 m
3.60 m
600 mm
3.60 m
600 mm
3.60 m
N/A
N/A
Equal to the
width of the
stairway
800-900 mm
from the nosing
N/A
800-1200 mm from
the nosing
800-1200 mm
from the nosing
700-800 mm
from the floor
P.D 957
Subdivision &
Condominium
Law
B.P 220
Economic
Housing
B.P 220
Socialized
Housing
B.P 344
Accessibility
Law
1.00 m for
major road &
minor roads
N/A
N/A
N/A
1:3 or 1:4
N/A
1:3 or 1:4
N/A
N/A
N/A
1:10
10%
1:10
15%
15%
1:12 but
length shall not
exceed 6.00 m
w/o landing
50% Residential
25% others
N/A
50% Residential
25% Others
50% Residential
25% Others
50% Residential
25% Others
N/A
Inside Lots
20% Residential
15% others
N/A
20% Residential
15% Others
20% Residential
15% Others
20% Residential
15% Others
N/A
Corner/Through
Lot
Lot bounded by
streets on 3 sides
10% Residential
5% others
5% for all
occupancies
N/A
10% Residential
5% Others
5% for all
Occupancies
10% Residential
5% Others
5% for all
Occupancies
10% Residential
5% Others
5% for all
Occupancies
N/A
Setbacks
P.D 1096
Building Code
P.D 1185
Fire Code
P.D 957
Subdivision &
Condominium
Law
B.P 220
Economic
Housing
B.P 220
Socialized
Housing
B.P 344
Accessibility
Law
Low Density
Residential (R-1)
5.00 m Front
2.00 m Side
2.00 m Rear
3.00 m Front
2.00 m Side
2.00 m Rear
2.00 m Front
2.00 m Side
2.00 m Rear
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
3.00 m Front
2.00 m Side
2.00 m Rear
1.5 m Front
2.00 m Side
2.00 m Rear
1.5 m Front
2.00 m Side
2.00 m Rear
N/A
N/A
2.40 x 5.00 m
(perpendicular &
diagonal)
2.00 x 6.00 m
(parallel)
2.40 x 5.00 m
(perpendicular &
diagonal)
2.00 x 6.00 m
(parallel)
2.40 x 5.00 m
(perpendicular &
diagonal)
2.00 x 6.00 m
(parallel)
3.70 x 5.00 m
Pooled Parking 1
slot/ 10 units
Pooled Parking 1
slot/ 10 units
Pooled Parking 1
slot/ 10 units
N/A
1 slot /8 units
1 slot/ 4 units
1 slot/ 1 unit
1 slot / 20 units
1 slot / 20 units
N/A
Medium Density
Residential (R-2)
High Density
Residential (R-3)
N/A
N/A
Parking
Size of Parking
Slot
Low-income single
detached living
units w/ individual
lot size not more
than 100 sq. m
50 sq. m below
50-100 sq. m
100 sq. m above
2.40 x 5.00 m
(perpendicular &
diagonal)
2.00 x 6.00 m
(parallel)
Pooled Parking 1
slot/ 10 units
1 slot /8 units
1 slot/ 4 units
1 slot/ 1 unit
N/A
N/A