1.0 Introduction
These Standard Terms and Conditions of Sale of Engine
Part/Component Repair Services of SNECMA SA (hereinafter called
"SNECMA"), together with any terms and conditions, set forth in
SNECMA' signed proposal ("Proposal") submitted to the customer
identified in the Proposal ("Customer") and with the approved
workscope shall be the only terms and conditions applicable to the
provision by SNECMA of Services (as hereafter defined) for the repair
(performed in accordance with OEM Engine Shop Manual or SNECMA
Maintenance Manual), overhaul or servicing of the Engine part or
component of Customer's aircraft engines, engine modules, engine
module units, assemblies, subassemblies, controls and accessories,
and the parts incorporated in any of those items thereof described in
such Proposal (individually or collectively, as the case may be, the
"Equipment"). The term "Service(s)" means the services which
SNECMA agrees to perform as described in the Proposal and in the
approved workscope (whether or not contained in the Proposal),
including all labor and materials used by SNECMA in the performance
thereof.
These terms and conditions (STCS), together with the signed and
accepted Proposal and with the approved workscope, shall be
considered as the agreement between the parties and shall be in lieu of
any and all terms and conditions of any purchase order or other
document submitted by Customer except as specifically stated
hereinafter.
Pricing contained in these STCS are the prices available on the
SNECMA Website, www.snecma.com, update regularly.

SNECMA reserves the right to adjust pricing throughout the year for
any business need including but not limited to correcting any pricing
error that is identified following issuance of this these STCS.

2.0 Definitions
Accessories: Fixed price including labour and material with exceptions
(FOD, misused, fuel contamination, mishandling, major part bodies)

AD or Airworthiness Directive shall mean a document issued by the
Competent Aviation Authority having jurisdiction over the Equipment,
identifying an unsafe condition relating to such Equipment and, as
appropriate, prescribing inspections and the conditions and limitations,
if any, under which the Equipment may continue to operate.

Cleaning and Inspection costs and TAT are not included for the CRD
dedicated to customer with Snecma Engine Overaul Contract but shall
be added for CRD dedicated for isolated parts and accessories
Business, packages or repairs.
If part fails inspection, clean and serviceability fees apply.
Any additional factory testing, inspection and packaging requirements
of Customer shall be paid for by Customer.

CLP or Catalog list Price shall mean the OEMs current catalog or the
OEMs current list price pertaining to a new part or new item of
Equipment. The term current as used in this definition means as of
the time of providing such part or item during the applicable Service.

Designated Repair Facility shall mean one or more of the repair
facilities owned by SNECMA or its affiliates, which are certified by the
Competent Aviation Authority to perform the applicable Service
hereunder. A list of repair facilities currently owned or operated by
SNECMA or its affiliates is set forth in Article 15 hereunder.
The Services on the Equipment shall be performed at the repair facility
designated in Customers Purchase Order as agreed by SNECMA.
However, SNECMA has the right to change the Designated Repair
Facility and to subcontract any Services to any other SNECMA repair
facility, SNECMA-affiliated facility, or to any subcontractor selected by
SNECMA, as long as such repair facility, SNECMA affiliated facility or
subcontractor is certified and rated by the Competent Aviation Authority
to perform the required Services on the Equipment.

Material listed at CLP is sometimes requested by the ESM repair. This
cost shall be added excepted if specified otherwise at CRD repair
description.

SB or Service Bulletin shall mean the document issued by an OEM to
notify the engines operator of modifications, substitution of parts,
special inspections, special checks, amendment of existing life limits or
establishment of first-time life limits, or conversion of Equipment from
one model to another.

Turnaround Time (TAT) means the number of calendar days,
between Delivery and Redelivery, required to complete repairs,
exclusive of public holidays observed by the Designated Repair
Facility, Excusable Delays, and any delays due to acts of Customer or
failure to act by Customer.

- The Turn Around Time shall begin the day SNECMA acknowledges
receipt of the Equipment to be repaired in the Designated Repair
Facility as evidenced by the date shown on the shipping documents or;
from the date of acceptance by the Customer of SNECMA 's quotation
as proven on the purchase order, whichever is the latest.
- The Turn Around Time terminates the day of the notice advising the
Customer that the component is ready for shipment or; when the
component leaves the Designated Repair Facility to be returned to the
Customer as evidenced by the date shown on the shipping documents,
whichever occurs first, provided the notice of the Customer
acceptation of the quotation and all necessary information for SNECMA
to perform the repairs have been received by SNECMA on due time.

To this effect the Customer shall provide with its purchase order or at
SNECMA's request all relevant information to enable SNECMA to
perform the Services.
In case of disregard of the Customers obligations, TAT shall be
modified accordingly. When all information is available to SNECMA and
if the TAT has been exceeded by more than 50%, SNECMA shall
consider providing standard exchange for the Equipment for which the
Services was to be performed, which Equipment shall become the
property of SNECMA. The price to be paid by the Customer shall be
the price of Service of the initial Equipment.

3.0 General Procedure
A. Following Delivery (as defined below) of the Equipment to SNECMA
Designated Repair Facility, together with (1) a repair/purchase order
from Customer authorizing such Service, (2) an approved workscope if
any, and (3) all applicable Equipment records, SNECMA shall induct
the Equipment and proceed with the Service described in the Proposal.
SNECMA shall perform a standard receiving inspection of the
Equipment and shall submit a workscope to Customer for approval, if
not already defined in the Proposal. If Customer decides not to proceed
with the Service, Customer shall immediately notify SNECMA in writing
of its decision not to proceed and shall pay to SNECMA all costs and
labor charges incurred in connection with the inspection of the
Equipment, including, without limitation, preparation of inspection
report(s), loose assembly and packing of the Equipment for return
shipment.
B. Following disassembly and/or inspection of the Equipment,
SNECMA shall provide Customer with an estimate of the Redelivery
(as defined below) date.
C. Should SNECMA discover some additional work to be performed
after approval of workscope by Customer, SNECMA shall so notify
Customer and perform such additional work, which shall be embodied
in the Services, at Customer expense unless Customer notifies
SNECMA in writing within five (5) days of receiving such notification
that Customer does not want such additional work to be performed.
D Service shall be in accordance with SNECMA standard commercial
quality control policies, procedures and practices. SNECMA shall
determine which parts are required to repair the Equipment. These
parts shall be charged to Customer under the terms and conditions set
forth in Article 4 Price Mark up below, unless specified in the
SNECMA directory that the Services includes the primary parts.
E. Serviced Equipment shall be prepared and packed in accordance
with SNECMA' normal commercial practice unless otherwise specified
in the Proposal. SNECMA agrees to comply with all reasonable written
instructions of Customer as to markings to be placed on bills of lading,
packing lists, correspondence and shipping containers.
F. In connection with the Services provided on the Equipment,
SNECMA shall provide Customer with copies of all work records
required by the European Aviation Safety Agency ("EASA"), or, if
applicable, the Federal Aviation Administration of the United States
("FAA"), or such other foreign equivalent aviation authority as agreed to
in writing by SNECMA and Customer (each, a "Competent Aviation
Authority"), including any required repair facility component/accessory
tags.

4.0 Price
All prices are shown in United States Dollars. They are valid until
the next update of the prices.

The Services described in this directory are only payable in U.S.$.
Prices shall be as quoted by SNECMA to Customer in the Proposal or,
if not, set forth in the Proposal, as published in SNECMA or other
original equipment manufacturer's ("OEM") directories in effect at the
time the item is allocated to, or incorporated in, Customers Equipment.
SNECMA directories or other OEM directories are published once a
year at least and is subject to evolution during a year, including without
limitation creation of new repairs; such evolution shall be applicable
immediately even if not published in the current SNECMA directories.

Snecma | All rights reserved 1/18
MATERIAL MARK UP
Mark up on primary parts replacement will be 10 % over Original
Engine Manufacturer (O.E.M.) directory price.
Exchange fee is 7 % of the O.E.M. directory price on the part to be
replaced if rotable parts are available.
Transfer of title is effective after payment of the corresponding invoices.
Serviceable parts will be supplied at 85 % of the directory price unless
otherwise agreed by the Parties.

CUSTOMER DEROGATION REQUEST (CDR)
Customer will be charged for any Customer's Derogation Request on a
part a management fee equivalent to 2% of the OEM directory price of
said part, such fee being not less than $ 200. This management fee
does not include labor and part.
The referring prices applied in the quotations are the prices available in
the SNECMA web site www.snecma.com updated regularly

5.0 Delivery, Redelivery, Title and Governmental Authorization
A. Customer's Equipment shall be Delivered Duty Paid ("DDP") to
SNECMA' Designated Repair Facility pursuant to International
Chamber of Commerce "Incoterms" (2000 Edition) ("Delivery").
SNECMA shall redeliver the Equipment to Customer, Ex Works, in
SNECMA' Designated Repair Facility pursuant to "Incoterms" (2000
Edition) ("Redelivery").
Incoterms :
- including transport packaging required for the return of the repaired
component to the Customer (packaging shall be in accordance with
SNECMA normal commercial practice). It excludes specific packaging
or shuttle ones that would not insure proper protection during the return
shipment.
- including SNECMA usual tests and inspections unless otherwise
specified in the directory.
- not including any transportation and charges related to transportation.
- not including the price of the parts, if required for the repair, unless
otherwise specified in writing by SNECMA.
Parts needed to perform the repairs shall be furnished by SNECMA
and deemed to have been sold to the Customer, the replaced primary
part to be scrapped by SNECMA. The transfer of title shall take place
at the same time as the transfer of risk.
These Incoterms are valid insofar no contrary quotation or notice shall
have been made by SNECMA after receipt of the Equipment to be
repaired.
B. Title to SNECMA furnished parts, material and associated labor shall
pass to Customer upon the first to occur of incorporation in the
Equipment, and simultaneously, title to parts removed from the
Equipment shall pass to SNECMA. Without further act or obligation on
the part of the Customer, SNECMA shall dispose of all scrapped or
condemned parts removed from the Equipment.
C. If Equipment cannot be Redelivered when ready due to any cause
referred to in Article 8 "Excusable Delay", below, SNECMA may place
such Equipment into storage. In such event, SNECMA shall notify
Customer of such storage, SNECMA' Redelivery obligations shall be
deemed fulfilled and all risk of loss or damage to the Equipment shall
pass to Customer on the date of such storage. Any amounts otherwise
payable to SNECMA upon Redelivery shall be payable upon
presentation of SNECMA' invoice. Promptly upon submission of
SNECMA' invoice, Customer shall reimburse SNECMA for all expenses
incurred by SNECMA, including, but not limited to, preparation for and
placement into storage, handling, inspections, preservation and
insurance of the Equipment. Upon payment to SNECMA of all amounts
due hereunder, SNECMA shall assist and cooperate with Customer in
the removal of any Equipment which has been placed in storage.
D. Customer shall be the importer or exporter of record of the
Equipment and, unless otherwise specifically agreed to in writing by the
parties, Customer shall be responsible for obtaining import licenses,
export licenses, exchange permits and any other required
governmental authorizations. At Customer's request and expense,
SNECMA will assist Customer in obtaining any required approval but
shall not be liable if any authorization is delayed, denied, revoked,
restricted or not renewed, and Customer shall not be relieved of its
obligation to pay SNECMA for Services and any other charges which
are the obligation of the Customer hereunder. All items (including
technical data) delivered hereunder shall at all times be subject to (i)
the U.S. Export Administration Regulations and/ or the International
Traffic in Arms Regulations and (ii) the French Export Administration
Regulations and applicable customs regulations of France and (iii) any
other foreign government export control regulations.. Customer agrees
not to dispose of U.S. or French origin items (including technical data)
provided by SNECMA under these STCS other than in and to the
country of ultimate destination specified in Customer's purchase order,
approved government license(s) or authorization(s), except as said
laws and regulations may permit.

6.0 Invoices and Payment
A. SNECMA shall provide Customer with a budgetary estimate of the
costs to perform Services and shall issue a preliminary invoice to be
paid by Customer before Redelivery of the Equipment. Any quotation or
cost estimate is provided and accepted by Customer only as a
budgetary estimate, solely for the purpose of guidance and not for
reliance. SNECMA shall issue a final invoice for Services as soon as
practicable after completion of the Services. The final invoice shall
reflect the total charges owed by Customer and credits due Customer
and shall reflect any additional charges or credits to the preliminary
invoice incurred (if any), based on actual charges to complete the
Services. Such invoice shall be reconciled with any preliminary invoice.
Unless otherwise stated in the Proposal, the unpaid balance of any
preliminary invoice for Services shall be payable in full prior to
Redelivery of the Equipment. Customer shall pay the final invoice at
receipt. If any payment date falls on a day that is not a business day,
the payment that is otherwise due shall instead be due the next
business day. Timely payment by Customer shall be of the essence of
these STCS and SNECMA reserves the right to require different terms
of payment or other assurances of payment in the event Customer fails
to make timely payments such as an advance payment of 100% of the
estimated amount of the works and parts. The remainder at receipt of
invoice. The invoice will be deemed to be received no later than seven
(7) days from date of issue.
B. Customer shall make all payments under these STCS in United
States Dollars via wire transfer to the bank account designated on the
Proposal.
Such payment shall be immediately available for use and without any
right to withhold or to make any deduction whatsoever unless accepted
by SNECMA or affirmed by the competent court as per article 13,
Paragraph A.
C. SNECMA shall have the right, in addition to all other rights and
remedies afforded to it under these STCS or by law, to suspend
performance of its obligations under these STCS should Customer
default in the performance of its obligations under this article, and to
charge Customer for the corresponding costs associated with the work
stoppage.
D. If Customer is in default of any payment obligation, SNECMA is
without reminder and prejudice to any other rights entitled to charge
interest at Libor 3 month plus 4% for any outstanding sum, beginning
with any due date of payment.
E. Customer hereby grants to SNECMA a security interest in any
property owned by Customer (including Customers beneficial rights to
property leased by Customer) in the possession of SNECMA or any of
SNECMA affiliates, at any time, to secure all amounts owed by
Customer to SNECMA under these STCS.
F. For each final invoice, Customer will be charged at least a lumpsum
of 150$ regardless of the repair price.

7.0 Taxes
A. Any taxes of any nature levied exclusively in connection with
transactions hereunder, whether levied against Customer or Snecma,
shall be borne, and to the extent permitted by law, paid directly by the
Customer to the relevant authority.
If Snecma is required by law or otherwise to pay any such taxes,
including any related penalties and interest, the amount of the payment
so made by Snecma shall be reimbursed by Customer to Snecma upon
submission of Snecmas invoices.
Customer will use all reasonable effort to obtain a refund thereof. If all
or any part of any taxes be refund to Snecma, Snecma will repay
Customer such part thereof as Customer will have paid or reimbursed
to Snecma.
B. Withholding - All payments to be made by Customer to Snecma
under this agreement shall be free of all withholding of any nature
whatsoever except to the extent otherwise required by law; and if any
such withholding is so required, Customer will:
- Promptly notify Snecma; and
- Forthwith pay to Snecma such additional amount necessary to
ensure that, after the making of such deduction or withholding,
Snecma receives and retains a net amount equal to the full
amount which it would have received had no such deduction or
withholding been made or required to be made; and;
- Pay the full amount required to be deducted or withheld to the
relevant taxation authority within the time allowed for such
payment under applicable law; and
- Provide Snecma, in the same time of the payment, with a
certificate of deduction of tax at source.
If the aforesaid mechanism contravenes the law of [COUNTRY], the
Parties shall amend this Agreement in order to increase the respective
prices and mount envisioned by this Agreement so that the initial prices
and amounts are preserved.
C. Value Added and similar taxes - Transactions contemplated
between Snecma and Customer under this agreement will be governed
by European Community regulation in force (to date, Council directive
2006/112/EC).
Should value added tax or similar tax be applicable to the contemplated
transaction, Snecma will be entitled to invoice Customer such tax in
addition to the price hereto, unless Customer provides Snecma with
adequate exemption.

Snecma | All rights reserved 2/18
D. Assistance - It is expressively agreed between the Parties that
Customer will do its best effort to assist Snecma in the following
situations:
- Obligation for Snecma to provide any public authorities within the
jurisdiction of the Customer with any return of administrative, legal
or fiscal nature;
- Dispute with any public authorities within the jurisdiction of
Customer relative to matters of fiscal or customs nature with
respect to this agreement or the performance of this agreement
on.

8.0 Excusable Delay
SNECMA shall be excused from, and not be liable for, any delay in its
performance or failure to perform due to causes beyond SNECMA
reasonable control, including, without limitation, acts of God, war,
warlike conditions, inability to secure parts, material or transportation,
insurrection, riot, explosions, fires, government acts or failure to act,
government priorities, acts or failure to act of civil or military authorities,
labor disputes, strikes or Customers acts (or failure to act) as required
under the terms of these STCS. In the event of such delay, SNECMA
shall have the right to invoice Customer for all completed Service, and
Customer shall pay such invoice net thirty (30) days. Should
Customer's action or inaction (such as, without limitation, delay in
providing Customer owned property, Equipment records, approval or
other information), cause a delay, Customer's Equipment may be
removed from production, which may result in greater than day-for-day
delay. If delay resulting from any of the foregoing extends for more than
six (6) months and the parties have not agreed upon a revised basis for
continuing the Service, including an adjustment of the price, then upon
thirty (30) days written notice to the other, either party may terminate
their performance in respect to the Service delayed. In the event of
such a termination Customer shall pay SNECMA' termination charges
upon receipt of SNECMA' invoice(s) therefore.

9.0 Warranty
A. SNECMA warrants to Customer that, at the time of Redelivery, the
work performed under these STCS will be free from defects in
workmanship for a period of one thousand (1000) running hours after
repair or six (6) months after installation or one year from date of end of
repair, whichever shall first occur.
Customer shall send SNECMA written notice of a defect prior to the
expiration of thirty (30) days following discovery thereof. If SNECMA
reasonably determines that the work performed does not meet the
warranty specified above, SNECMA shall promptly correct the defect
by, at SNECMA option, (1) repairing the defective work, (2) making
available at the Designated Repair Facility a repaired or replacement
item, or (3) refunding the repair price allocable to the defective work.
The warranty period on any such repaired or replaced item shall be the
unexpired portion of the warranty on the initially repaired item. If
requested by SNECMA, Customer shall ship such defective item,
freight prepaid, to the location specified by SNECMA. If SNECMA
determines that a repair is covered by this warranty, SNECMA shall
reimburse Customer for its reasonable freight charges in connection
with the transportation of such item to SNECMA.
B. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF
ALL OTHER WARRANTIES, WHETHER WRITTEN, ORAL,
EXPRESSED, IMPLIED OR STATUTORY (including, without limitation,
any warranty of merchantability and fitness for particular purpose).
This warranty is not assignable without the written consent of
SNECMA. This warranty is applicable only if: the Equipment, following
Redelivery, (1) has been transported, stored, installed, operated,
handled, maintained and repaired in accordance with the then-current
recommendations of the Equipment manufacturer as stated in its
manuals, Airworthiness Directives, Service Bulletins or other written
instructions; (2) has not been altered, modified or repaired by anyone
other than SNECMA; and (3) has not been subjected to accident,
misuse, abuse or neglect.
C. The liability of SNECMA connected with or resulting from the
foregoing warranty shall not exceed in any case the cost of correcting
the defect as provided in paragraph A above. Upon the expiration of
the shortest period described in paragraph A above, all such liability
shall terminate. The foregoing shall constitute the sole remedy of
Customer and the sole liability of SNECMA for breach of warranty.

10.0 Limitation of Liability
A. The total liability of SNECMA for any and all claims, whether in
contract, warranty, tort (including negligence but excluding wilful
misconduct or recklessness), product liability, patent infringement, or
otherwise, for any damage arising out of, connected with, or resulting
from the performance or non-performance of any Service provided
hereunder or from the manufacture, sale, Redelivery, resale, repair,
overhaul, replacement or use of the Equipment or any item or part
thereof, shall not exceed the price allocable to the repaired or
overhauled item, part or Service which gives rise to the claim.
Consequently, Customer and its insurers waive any recourse against
SNECMA for any loss or damage beyond that limit.
B. Customer shall defend, indemnify and hold harmless SNECMA for
and against any and all losses, claims, suits, judgements, costs and
expenses, including but not limited to reasonable attorney fees and all
associated costs therewith, which may be incurred by, charge to,
recoverable from or which may accrue against SNECMA by virtue of a
claim by a third party for injury or death to person or damage to
property as a result of the negligent performance or non performance
by SNECMA of its obligations under these STCS, except to the extent
that that such injury, death or damage is determined to be due solely
and directly to SNECMA recklessness or willful misconduct.
C. In no event, whether as a result of breach of contract, warranty, tort
(including negligence but excluding willful misconduct or recklessness),
product liability, patent infringement, or otherwise, shall SNECMA be
liable for any indirect damages (for avoidance of doubts indirect
damages shall cover any similar types of damages such as but not
limited to, special, consequential, incidental, resultant, punitive or
exemplary damages, including, without limitation, loss of use, revenue,
image, profit or goodwill).
D. For the purpose of this Article 10, the term "SNECMA" is deemed to
include SNECMA and its affiliated companies, the subcontractors and
suppliers of the Services furnished hereunder, and the directors,
officers, employees, servants and representatives of each.

11.0 Information
A. Unless otherwise specifically agreed upon in a proprietary
information agreement signed by the parties, any knowledge or
information which Customer has disclosed or may hereafter disclose to
SNECMA, incident to the Service or Equipment, shall not be deemed to
be confidential or proprietary information, and, accordingly, shall be
acquired free from any restriction on use or disclosure.
B. The existence of these STCS and their general purpose may be
stated to others by either of the parties without approval from the other
except that the terms of these STCS and any knowledge or information
which SNECMA may disclose to Customer with respect to pricing,
design, manufacture, sale, use, repair, overhaul or Service of
Equipment shall be deemed to be proprietary information and shall be
held in confidence by Customer. Such information shall not be
reproduced, used or disclosed to others by Customer without
SNECMA' prior written consent, except to the extent required by
government agencies or courts for official purposes. Disclosure to such
government agencies or courts shall be made only (1) upon thirty (30)
days advance written notice to SNECMA of such disclosure so as to
provide SNECMA the ability to obtain appropriate protective orders and
(2) with a suitable restrictive legend limiting further disclosure.
C. The preceding paragraph B shall not apply to information which (1)
is or becomes part of the general public knowledge or literature
otherwise than as a result of breach of Customer's obligations
hereunder, or (2) was, as shown by written records, known to
Customer prior to receipt from SNECMA, or (3) is disclosed without
restriction to Customer by a third party having the right to do so.
D. Nothing contained in these STCS shall convey to either party the
right to use the trademarks of the other, or convey or grant to Customer
any license under any patent owned or licensed by SNECMA.

12.0 Termination
Either party may terminate these STCS upon thirty (30) days written
notice to the other for failure to comply with any material provision of
these STCS unless the failure shall have been cured, or the party in
breach has substantially affected all acts required to cure the failure,
prior to such thirty (30) days. SNECMA may immediately terminate
these STCS if Customer (1) fails to make any of the required payments
when due, unless cured within ten (10) days of such payment due date,
(2) makes any agreement with creditors due to its inability to make
timely payments of its debts, (3) enters into liquidation whether
compulsory or voluntary, (4) becomes insolvent, or (5) becomes
subject to the appointment of a receiver of all or a material part of its
assets. If such termination should occur, Customer shall not be relieved
of its payment obligation for Services rendered hereunder.

13.0 Dispute Resolution
A. Arbitration Procedure. All disputes arising out of or in connection
with these STCS, may be exclusively referred by any party that is
involved in the dispute, and to the exclusion of any competent court, to
binding arbitration and, if so referred, shall be fully and finally resolved
under the Rules of Conciliation and Arbitration of the International
Chamber of Commerce (the "Rules") by one or more arbitrators
appointed in accordance with said rules. The place of arbitration shall
be Paris, France.
The arbitration shall be in English and the opinion shall be rendered in
French. The arbitration award may be presented and enforced by any
party in any court of competent jurisdiction.
Notwithstanding the foregoing, SNECMA may at any time seek from a
court of competent jurisdiction any relief to avoid irreparable damage
occurring in the event obligation set forth in article 6 here above was
not performed in accordance with the terms hereof.
Snecma | All rights reserved 3/18
B. Exclusivity, Confidentiality. Each of the parties intends that the
dispute resolution process set forth in this Article shall be the parties
exclusive remedy for any dispute. All statements made in connection
with the dispute resolution process set forth in this Article shall not be
disclosed to any third party except as required by law or subpoena.
C. Exception. Any party may at any time, without inconsistency with
this Article, seek from a court of competent jurisdiction any equitable,
interim, or provisional relief to avoid irreparable harm or injury.
D. Applicable Law. These STCS are construed and governed in all
aspects by the laws of France.

14.0 General Provisions
A. Right to Subcontract. SNECMA shall have the right to have any of
the Services performed at any SNECMA facility or any facility of
SNECMA' affiliates, or any subcontractor selected by SNECMA or such
affiliates, provided such facility, affiliate or subcontractor is properly
certified and rated by the Competent Airworthiness Authority to perform
such work. SNECMA use of affiliates or subcontractors shall not
relieve SNECMA from the responsibility for the proper performance of
its obligations set forth in these STCS.
B. Assignment. Except as described in paragraph A above, the
assignment of all or any portion of these STCS, or any purchase order
or any right or obligation hereunder, by either party, without the prior
written consent of the other party shall be void. Notwithstanding the
foregoing, the Customer's consent shall not be required for the
substitution of a SNECMA affiliate in place of SNECMA as the
contracting party or the recipient of payments pertaining to all or any
portion of these STCS or any purchase order or any right or obligation
in connection with these STCS. In the event of any such substitution,
Customer shall be so advised in writing, although failure to so advise
shall not be cause for termination hereunder.
C. Waiver of Immunity. To the extent that Customer or any of its
property becomes entitled at any time to any immunity on the grounds
of sovereignty or otherwise from any legal action, Customer hereby
irrevocably waives the application of such immunity insofar as such
immunity relates to Customer's rights and obligations in connection
with these STCS.
D. Partial Invalidity : If any provision of these STCS shall be held to be
invalid, illegal or unenforceable, the validity, legality and enforceability
of the remaining provisions shall not in any way be affected or impaired
thereby.
E. Beneficiaries. Except as herein expressly provided to the contrary,
the provisions of these STCS are for the benefit of the parties hereto
and not for the benefit of any third party.
F. Language, Notices. All correspondence and documentation arising
out of or connected with these STCS and any related purchase
order(s), including but not limited to Equipment records and logs, shall
be in the English language. Any notices furnished under these STCS:
(1) shall be in writing, (2) shall become effective upon receipt, and (3)
shall be delivered or sent by mail or electronic transmission to the
address set forth on the Proposal, which may be change by written
notice to the other party.
G. Non-Waiver. Any failure by either party to enforce any of the
provisions of these STCS or to require at any time performance by the
other party of any of the provisions hereof shall in no way affect the
validity of these STCS or any part hereof, or in the right of the parties
thereafter to enforce each and every such provision; nor shall the
parties actual performance, whether or not under these STCS, be
deemed in any way indicative of the scope of the obligations of the
parties under these STCS.
H. Titles/Subtitles. The titles and subtitles given to the sections of these
STCS are for convenience only and shall not be deemed to limit or
restrict the context of the article or section to which they relate.
I. Entire Agreement. These STCS contain and constitute the entire and
only agreement between the Parties hereto respecting the subject
matter hereof, and supersedes and cancels all previous negotiations,
agreements, proposals, statements, course of dealing or usage of
trade, commitments and writings in connection therewith.
These STCS may not be released, discharged, abandoned,
supplemented, changed or modified in any manner, orally or otherwise,
except by an instrument in writing of concurrent or subsequent date
signed by a duly authorized representative of each of the parties
hereto.
J. Counterparts: These STCS may be executed by the parties in
separate counterparts, each of which shall be deemed to be an original
and all of which, when taken together, shall constitute one and the
same document. Delivery of an executed counterpart of a signature
page to these STCS by fax shall be as effective as delivery of a
manually executed counterpart.








16.0 Repair centers
Snecma Villaroche
Rond Point Ren Ravaud REAU
77550 MOISSY-CRAMAYEL
France
Customer Support Manager : Franois Degras
Tel : 33 (0) 1 64 14 85 83
Fax 33 (0) 1 64 14 89 60
francois.degras@snecma.fr

Snecma Saint Quentin
1, Rue des frres Farman
78771 Magny-les-Hameaux Cedex
France
Customer Support Manager : Laurent Picot
Tel. : 33 (0) 1 30 96 28 00 / 57 52
Fax. : 33 (0) 1 30 96 27 23
laurent.picot@snecma.fr

Snecma Chatellerault
Z.I. Nord - Rue maryse Basti
BP 129
86101 Chtellerault Cedex
France
Customer Support Manager : Bruno Roy
Tel. : 33 (0) 5 49 20 45 00 / 45 29
Fax. : 33 (0) 5 49 20 22 43
bruno.roy@.snecma.fr

Snecma Sevices Bruxelles
Btiment 24B - Local 305
Aroport Bruxelles National
BP 1930 Zaventem
Belgium
Customer Support Manager :
Tel. : 32 2 790 45 00
Fax. : 32 2 790 47 99

Propulsion Technologies International
15301 SW 29th Street
Miramar, Fl 33027
USA
Director of Sales : Gregory Ryan
Customer Service : Evelyn Valenciano
Tel. : +1 (786)-999-0600
Fax. : +1 (954)-874-0301
evelyn.valenciano@ptechi.com

Aircelle Europe Services
Zone industrielle de Saint Ulfrant
27500 Pont Audemer
France
Tel : 02.32.20.40.00
Fax : 02.32.20.40.50

17.0 Sales Interfaces
Philippe DUMAY
SALES DIRECTOR
Phone : +33 (0)1 60 59 88 16
Fax : +33 (0)1 60 59 55 01
philippe.dumay@snecma.fr

Pascal RONDOUIN
SALES DIRECTOR
Phone : +33.(0)1 60 59 41 37
Fax : +33 (0)1 60 59 55 01
pascal.rondouin@snecma.fr

Snecma | All rights reserved 4/18
HARNESS MW0301>0304 &
MW0312>0313 Villaroche
325-015-001-0 MW0301/0302/0303/0304/0312/0313
18224 325-026-401-0 Inspection test 21 1150
325-026-501-0 MW0301/0302/0303/0304/0313
18222 325-026-701-0 Minor repair 21 2000
325-026-801-0 MW0312
20513 325-026-901-0 Minor repair 21 3400
325-026-902-0 MW0301/MW0304
20509 325-035-201-0 Major repair 21 3400
325-035-501-0 MW0312
20515 325-035-502-0 Major repair 21 8200
325-045-301-0 MW0302/MW0303
20510 Major repair 21 2700
MW0313
20514 Major repair 21 4100
HARNESS FOR NACELLE -
MW0311 Villaroche
325-029-901-0
12886 325-029-902-0 TEST INSPECTION 21 1150
325-029-903-0
20511 325-029-904-0 Minor repair 21 2600
325-029-905-0
20512 Major repair 21 5500
23922 NEW MW0311 ELECTRICAL HARNESS 21 1800
FAN ROTOR BLADE
Saint Quentin - PTI
340-001-022-0
11663 340-001-026-0 CLEANING / INSPECTION 7 70
340-001-027-0 BASIC OVERHAUL
11664 BLEND REPAIR OF THE BLADE AIRFOIL +21 +377
SHOTPEENING OF THE FAN ROTOR BLADE
REPAIR OF CU-NI-IN THERMAL SPRAY COATING AND DRY
FILM LUBRICANT VARNISH ON THE ROOT
11665 STRAIGHTENING OF THE AIRFOIL +7 +850
23514 Reconditioning face mating with booster +7 +452
11731 REWORK ROOT PRESSURE FACE UNDERCUT (CFM special
program)
+7 +377
23532 Static Moment weight +151
22747 REPAIR OF THE FAN BLADE PER CDR. (CFM technical data) +162
23901 MAPPING ENGINE SET. PRICE PER BLADE +7
FAN DISK
PTI
340-000-410-0
11983 340-000-415-0 Cleaning / Incoming inspection 7 1356
340-000-420-0 STANDARD REPAIR
18334
340-000-471-0
REPLACEMENT OF THE CRIMPED SELF- LOCKING NUTS ON
THE SPINNER REAR CONE ASSY
+30 +20 744
340-000-472-0
340-000-473-0 REPLACEMENT OF THE CRIMPED SPACERS
REPAIR OF DOVETAIL SLOT PRESSURE FACES ON THE FAN
DISK
SB 72-0324 OR 72-0585
22125 REPLACEMENT OF THE CRIMPED SELF- LOCKING NUTS ON
THE SPINNER REAR CONE ASSY
+30 +22 319
REWORK OF THE FAN DISK
REPLACEMENT OF THE CRIMPED SPACERS
BLENDING OF THE FAN DISK
REPAIR OF DOVETAIL SLOT PRESSURE FACES ON THE FAN
DISK
11984 REPLACEMENT OF THE CRIMPED SELF- LOCKING NUTS ON
THE SPINNER REAR CONE ASSY
+1 137
20230 BLENDING OF THE FAN DISK +1 675
21818 REPAIR OF THE FACE THAT MATES WITH THE SEALING
FLANGE OF THE BOOSTER SPOOL
+2 999
11985 REPLACEMENT OF THE CRIMPED SPACERS +1 137
19125 REPAIR OF PAINT MARKING +1 304
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
TESTA
MIR
MIR
MAR
MAR
MAR
MAR
INSP
002
004
007
MIR
MAR
SB 72-0062
CINSP
CINSP
002
011
016
002
011
012
016
SB 72-0324
002
012
013
016
017
715101
715102
722101
722103
SP MP
014
SB 72-0253
SP MW
CDR
001
Snecma | All rights reserved 5/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
21819 REPAIR OF LOCKS BY PLASMA SPRAYING +2 822
22719 REPAIR OF THE FAN DISK PER CDR +14 +2 191
11434 FPI + ECI +2 217
SPINNER FRONT CONE
PTI
337-005-118-0
13064 340-000-205-0 Cleaning / Incoming inspection 21 209
20597 REMOVAL OF SURFACE DEFECTS AND SPOT TOUCH-UP OF
OXIDE FILM COATING OR RESTORATION OF AERODYNAMIC
PROFILE AND FULL RECONDITIONING OF HARD ANODIZING
+783
22267 REMOVAL OF SURFACE DEFECTS AND REPAIR OF THE
SULFURIC ANODIZING, ANTI-EROSION PAINT, AND WHITE
SPIRAL MARK ON THE SPINNER FRONT CONE
+1 043
19243 REPAIR OF THE SPINNER FRONT CONE DIAMETER THAT
LOCATES THE SPINNER REAR CONE
+1 518
13065 REPLACEMENT OF THE DEFECTIVE SWAGED SELF-LOCKING
INSERTS ON THE SPINNER FRONT CONE ASSEMBLY
+418
SPINNER REAR CONE
PTI
337-005-118-0
11328 Cleaning / Incoming inspection 14 209
13021 SPOT TOUCH-UP OF THE HARD ANODIZING ON THE
SPINNER REAR CONE
+586
20781 REPLACEMENT OF CRIMPED SELF LOCKING NUTS ON
SPINNER REAR CONE
+7 +1 252
21854 REPAIR OF THE SPINNER REAR CONE DIAMETERS +7 +2 514
22798 Repair of the Spinner Rear Cone Mating Faces with the Retaining
Flange and/or the Spinner Front Cone
+7 +2 723
BOOSTER VANE STG 1
PTI
340-001-307-0
22780 340-001-308-0 Cleaning and serviceability inspection 21 418
340-001-309-0 STANDARD REPAIR
22202 340-001-310-0 Blending of vane airfoil +3 724
Reconditioning of abradable coating on outer shroud
21163 Blending of vane airfoil +897
22203 Reconditioning of abradable coating on inner shroud +2 457
21164 Reconditioning of abradable coating on outer shroud +3 129
22781 Reconditioning of the front flange rabbet diameter +1 669
22782 Reconditioning of front flange rabbet outer diameter +1 669
24001 Replacement of inner shroud +3 360
22692 Improvement of the Fan and Booster Vane Assy to Prevent the
Corrosion in Field Only
+1 899
BOOSTER VANE STG 2
PTI
335-192-202-0
22795 335-192-203-0 Cleaning and serviceability inspection 21 418
STANDARD REPAIR
22204 Blending of vane airfoil +3 755
Reconditioning outer shroud
21165 Blending of vane airfoil +897
22796 Reconditioning of abradable coating on inner shroud +2 457
22787 Reconditioning of front flange rabbet diameter +1 669
22788 Reconditioning of aft flange rabbet diameter +1 669
22789 Reconditioning of front flange mating face +1 669
22790 Reconditioning of aft flange mating face +1 669
23016 Replacement of vane one by one all stages +9 +10 165
018
CDR
AD 2002-13-03
CINSP
001
014
016
026
CINSP
001
002
002
003
017
025
CINSP
001
CINSP
001
003
001
002
010
011
012
013
036
722105
722105
722109
722109
006
007
028
SB 72-0454
003
001
Snecma | All rights reserved 6/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
BOOSTER VANE STG 3
PTI
340-058-302-0
22797 340-058-303-0 Cleaning and serviceability inspection 21 418
STANDARD REPAIR
22205 Reconditioning of abradable coating on outer shroud +3 724
Blending of vane airfoil
21166 Blending of vane airfoil +897
22206 Reconditioning of abradable coating on inner shroud +2 457
21167 Reconditioning of abradable coating on outer shroud +3 129
21168 Replacement of riveted self locking nuts +705
22792 Reconditioning of aft flange rabbet diameter +1 669
22791 Reconditioning of front flange rabbet diameter +1 669
22793 Reconditioning of front flange mating face +1 669
22794 Reconditioning of aft flange rabbet diameter +1 669
23017 Replacement of vane one by one all stages +9 +10 165
BOOSTER VANE STG 4
PTI
340-058-402-0
21169 340-058-404-0 Cleaning and serviceability inspection 21 418
340-058-405-0 STANDARD REPAIR
22207 340-058-406-0 Blending of vane airfoil +3 724
Reconditioning of abradable coating on outer shroud
21171 Blending of vane airfoil +897
21170 Reconditioning of abradable coating on inner shroud +2 457
21172 Reconditioning of abradable coating on outer shroud +3 129
21173 Replacement of riveted self locking nuts +705
23018 Replacement of vane one by one all stages +9 QUOTE
FAN BLADE PLATFORM
PTI
23487 340-001-814-0 CLEANING / INSPECTION 21
340-001-816-0 STANDARD REPAIR
22283 REPLACEMENT AND BONDING OF ELASTOMER SEALS (15-
93557)
+21 +501
Repair of corrosion damage (P/N340-001-816-0 only)
Repair the forward end concave side
WEIGHT ADJUSTEMENT OF PLATEFORM
FULL OR PARTIAL RECONDITIONNING OF PROTECTIVE
COATING (15-93555)
21807 APPLICATION OF SB 72-0586 FOLLOWING ESM 722120 +14 +131
VARIABLE BLEED VALVE GUIDE
PADS PTI
340-079-603-0 Price for one part
22772 340-079-604-0 Replacement of PTFE friction pad +21 +1 612
Cleaning, FPI, dimensional incoming inspection
Replacement of crimped self locking nuts or swaged self locking
insert
From 2 to 4 parts (price for each)
22773 Replacement of PTFE friction pad +21 +1 043
Cleaning, FPI, dimensional incoming inspection
Replacement of crimped self locking nuts or swaged self locking
insert
FAN SHAFT
PTI
1767M49G05
22824 1767M49G06 Cleaning / Incoming inspection 21 720
1767M49G07 Standard repair
22287 335-006-414-0 REPLACEMENT OF THE ALUMINUM PAINT +3 129
CINSP
003
722109
001
001
002
003
004
015
014
016
017
036
CINSP
001
722109
003
001
002
003
004
036
CINSP
002
722120
003
006
007
008
SB 72-0586
001
002
CINSP
722123
001
002
CINSP
CINSP
722201
001
Snecma | All rights reserved 7/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
REPLACEMENT OF ALL CRIMPED SELF-LOCKING SHANK
NUTS
21716 TOUCHUP PAINTING PER INSPECTION +522
22774 Reconditioning of the air/oil separator locating diameter +3 041
22775 Reconditioning of locating diameter with N1 bearin g sleeve +3 145
22776 Reconditioning of aft locationg diameter with LPT shaft +3 025
22777 Reconditioning of mating face with LPT coupling nut +2 264
22778 Reconditioning of tungsten carbide coating of N2 B earing locating
diameter
+5 737
22779 Reconditioning of locating diameter with the fan disk +3 578
23738 Repair of the LPT shaft midspan inner locating diameter +3 025
23737 Repair the locating diameter with fan disk assembly with plasma
spray
+2 608
21717 INTRODUCTION OF A NEW PROBE HOUSING WITH
INCREASED LENGTH INSERTS OR REWORK OF THE OLD
ONE
+1 268
21790 CLEANING + MPI +1 466
NO. 1 BEARING SLEEVE
PTI
301-297-812-0
22558 CLEANING / INSPECTION 21 319
22564 RECONDITIONING OF FWD LOCATING INNER DIAMETER +1 758
22565 RECONDITIONING OF FDW LOCATING OUTER DIAMETER +1 758
FAN OUTLET GUIDE VANE
PTI
340-002-305-0
22825 Cleaning / Incoming inspection 37
STANDARD REPAIR
11471 AIRFOIL AND PLATEFORM BLEND REPAIR +21 +183
RECONDITIONING OF THE PROTECTIVE COATING
21726 REMOVAL OF CORROSION AND REPAIR OF PROTECTIVE
COATING
+7 +53
COMPRESSOR ROTOR SPOOL
STAGE 1-2 Chtellerault
72-31-04
17895 CLEANING / INCOMING INSPECTION / AD 2002-13-03 / FPI 28 2140
17896 REPAIR OF ILLEGIBLE PART MARKINGS +420
23530 REPAIR OF FRETTED DOVETAILS +1 828
17897 REPAIR OF DIAMETER B +4 698
17898 REPAIR OF THE SEAL TEETH COATING +3 440
17899 APPLICATION OF THE MOLYDAG 254 COATING ON STAGES 1
AND 2 DOVETAILS
+3 091
17900 REPAIR OF FRETTED SURFACE G +1 634
22183 DOVETAIL REPAIR +742
22720 Blending per SP704111 +1 129
COMPRESSOR ROTOR DISK
STAGE 3 Chtellerault
72-31-05
21736 Cleaning / Incoming inspection 21 1613
12552 FPI +1 183
22721 Blending per SP704111 +1 054
22426 REPAIR OF THE RABBET DIAMETERS +4 714
COMPRESSOR ROTOR SPOOL
STAGE 4-9 Chtellerault
72-31-06
12575 CLEANING + FPI +28 +1 962
22293 REPAIR OF THE SEAL TEETH COATINGS +4 816
002
INSP01
004
005
006
008
010
014
011
016
SB 72-0298
AD 2002-13-03
CINSP
001
002
722212
002
003
004
CINSP
001
002
008
AD 2002-13-03
001
SP704111
CINSP
AD 2002-13-03
SP704111
722303
723104
723105
723106
002
005
006
007
008
CINSP
Snecma | All rights reserved 8/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
22307 REPAIR OF THE FORWARD AND AFT RABBET DIAMETERS +2 140
22228 BLEND REPAIR OF BLADE PLATFORM RAILS +1 505
23140 REPAIR OF THE SEAL TEETH COATINGS QUOTE
REPAIR OF THE FORWARD AND AFT RABBET DIAMETERS
COMPRESSOR ROTOR SHAFT
Chtellerault
1386M56P02
19918 1386M56P03 INSPECTION / TOUCH-UP THREADED END +28 +1 056
1590M28G01
12585 1590M28G02 FPI +1 223
1590M28G03
19794 1590M28G04 Blending per SP704111 +659
1590M28G05
19928 1590M28G06 REPAIR OF COATINGS ON THE SHAFT +4 363
1590M28G07
12311 1590M28G08 REPAIR OF THE LOCKING LUG SLOTS +28 +1 970
21414 REPAIR OF THE AFT FLANGE RABBET DIAMETERS +4 912
21417 REPAIR OF 4.6875-12 THREADS +925
19919 REPLACE THE THREADED END +12 708
19797 REPAIR OF AREA P +1 322
23141 REPLACE THE THREADED END QUOTE
REPAIR OF AREA P
CPR ROTOR REAR ROTATING
AIR SEAL (CDP) Chtellerault
1523M35P01
12325 Cleaning / Incoming inspection 21 1355
22534 AD +1 183
12326 REPAIR OF THE SEAL TEETH COATING +2 204
21606 REPAIR OF THE FORWARD AND AFT RABBETS +3 209
23142 REPAIR OF THE SEAL TEETH COATING QUOTE
REPAIR OF THE FORWARD AND AFT RABBETS
COMPRESSOR ROTOR AIR
DUCT PTI
9514M54
17880 Cleaning / Incoming inspection 418
Standard Repair
23096 REPAIR OF THE FORWARD MATING SURFACE +21 +4 442
REPAIR OF THE FORWARD MATING SURFACE OF THE AIR
DUCT DIAMETER BB
REPAIR OF THE AFT SUPPORT LUGS
REPAIR OF ILLEGIBLE PART MARKINGS
23740 REPLACEMENT OF COMPRESSOR ROTOR AIR DUCT SLEEVE QUOTE
23741 SUPPORT LUG REPAIR QUOTE
HPT INNER STATIONARY SEAL
(CDP) Chtellerault
1808M56G01
12220 Cleaning / Incoming inspection 7 525
Standard Repair
21159 REPLACEMENT OF THE SEAL CLINCH NUTS +21 +14 280
REPLACEMENT OF HONEYCOMB
17826 HEAT SHIELD REPLACEMENT +10 +13 934
COMBUSTION CHAMBER
SSB
724200 STANDARD REPAIR
22932 REASSEMBLY OF THE COMBUSTION CHAMBER + FINAL
INSPECTION
+28 +27 400
PRELIMINARY + INSPECTION (VISUAL) DISASSEMBLY
Standard repair
EXTENDED REPAIR
22933 REASSEMBLY OF THE COMBUSTION CHAMBER + FINAL
INSPECTION
+28 +33 726
003
004
001
003
INSP
723107
AD 2002-13-03
SP704111
002
004
005
006
007
008
007
008
CINSP
AD 2002-13-03
723108
001
003
001
003
002
CINSP
001
002
004
005
003
004
B
STDR
A
723111
724103
724200
B
006
007
CINSP
Snecma | All rights reserved 9/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
EXTENDED REPAIR
PRELIMINARY + INSPECTION (VISUAL) DISASSEMBLY
COMBUSTION CHAMBER INNER
AND OUTER COWLS SSB
1968M59G01
13109 CLEANING / INSPECTION +28 +678
22918 Weld repair and resize outer cowl +888
22941 Weld repair and resize inner cowl +888
23834 Labour Packages (complete units, only SAC)
COMBUSTION CHAMBER DOME
SSB
1275M27P04 STANDARD REPAIR
22919 1561M26G05 Cleaning / Incoming inspection 28 9267
SPECIAL SIZING TECHNIQUE - VENTURI DIAMETER SIZING
AND WELD REPAIR
WELD REPAIR AND BORING SCREW BOLT
REPLACEMENT OF THE PRIMARY SWIRL NOZZLE RETAINER
APPLICATION OF THE THERMAL BARRIER COATING
REMOVAL OF THE THERMAL BARRIER COATING
PRIMARY SWIRL NOZZLE ANTI ROTATION TANG REPAIR
WELD REPAIR AND RESIZE OF BOLTED COMBUSTOR DOME
EXTENDED REPAIR
22920 Cleaning / Incoming inspection 28 10285
SPECIAL SIZING TECHNIQUE - VENTURI DIAMETER SIZING
AND WELD REPAIR
SLEEVE - DEFLECTOR AND SWIRLER REPLACEMENT ON
DOME PER ONE SET INSERT
Primary swirl nozzle bore plasma spray wear repair
Sleeve and deflector replacement
WELD REPAIR AND BORING SCREW BOLT
REPLACEMENT OF THE PRIMARY SWIRL NOZZLE RETAINER
FLANGE REPLACEMENT
APPLICATION OF THE THERMAL BARRIER COATING
REMOVAL OF THE THERMAL BARRIER COATING
PRIMARY SWIRL NOZZLE REPAIR/REPLACEMENT
PRIMARY SWIRL NOZZLE ANTI ROTATION TANG REPAIR
WELD REPAIR AND RESIZE OF BOLTED COMBUSTOR DOME
22924 DEFLECTOR OF PLATE SPD REPLACEMENT +3 549
22925 DOME THICKBELLMOUTH SPD REPLACEMENT REPAIR +5 597
23827 SWIRLERS - THICK FLANGE QUOTE
23835 Labour Packages (complete units, only SAC)
COMBUSTION CHAMBER INNER
LINER SSB
1317M57G02 STANDARD REPAIR
22921 1317M57G03 Cleaning / Incoming inspection 28 8028
1968M64G01
1968M64G02 APPLY OF THE THICKNESS THERMAL BARRIER COATING
DRILL LINER BOLT HOLES
APPLY THE THERMAL BARRIER COATING
REMOVAL OF THE THERMAL BARRIER COATING
00C
001
002
COM
CINSP
724202
008
009
013
CINSP
001
002
005
006
001
002
003
005
006
007
008
009
010
011
012
013
004
014
SB 72-0455
COM
CINSP
005
006
007
012
724201
A
EXTR
724203
Snecma | All rights reserved 10/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
INSTALLATION OF THE NUT PLATES
REMOVAL OF THE NUT PLATES IN THE LINER
WELD REPAIR AND RESIZING AND STRESS RELIEF
EXTENDED REPAIR
22922 Cleaning / Incoming inspection 28 9041
Nugget wall thickness inspection
Brazed cooling hole inspection
APPLY OF THE THICKNESS THERMAL BARRIER COATING
AFT SUPPORT LEG WELD REPAIR
Repair inner liner bolt holes
DRILL LINER BOLT HOLES
APPLY THE THERMAL BARRIER COATING
REMOVAL OF THE THERMAL BARRIER COATING
INSTALLATION OF THE NUT PLATES
REMOVAL OF THE NUT PLATES IN THE LINER
WELD REPAIR AND RESIZING AND STRESS RELIEF
22926 INNER LINER SEAL PULSE TIG WELD REPAIR +1 491
Price per patch
22927 WELDED PATCH REPAIR +1 488
22928 WELD REPAIR OF NUT SUPPORT +615
23828 INNER LINER AFT FLANGE AND DATUM REPLACEMENT
SPARE PART REPAIR
QUOTE
23836 Labour Packages (complete units, only SAC)
COMBUSTION CHAMBER
OUTER LINER SSB
1317M56G0X STANDARD REPAIR
22929 1968M43G0X Cleaning / Incoming inspection 28 9429
1968M44G0X
1968M63G0X lug ring braze modification
APPLY OF THICKNESS THERMAL BARRIER COATING
IGNITOR FERRULE REPAIR / REPLACEMENT
IGNITER SLEEVE, FERRULE, RETAINER
WELD REPAIR AND RESIZING WITHOUT THE LUG RING
REPLACEMENT
BOLT HOLE DRILLING REPAIR
INSTALLATION OF THE LUG RING
REMOVAL OF THE COMBUSTION CHAMBER OUTER LINER
LUG RING
APPLY OF THE THERMAL BARRIER COATING
REMOVAL OF THE THERMAL BARRIER COATING
REPAIR OF THE PLASMA SPRAY WEAR COATING
EXTENDED REPAIR
22923 Cleaning / Incoming inspection 28 12784
brazed cooling hole inspection
lug ring braze modification
Nugget wall thickness inspection
Alf seal flange weld repair
Igniter port localized sizing repair and inspection
APPLY OF THICKNESS THERMAL BARRIER COATING
IGNITOR FERRULE REPAIR / REPLACEMENT
IGNITER SLEEVE, FERRULE, RETAINER
001
003
004
CINSP
001
003
004
005
006
007
010
011
012
SB 72-547
SB 72-521
002
008
004
005
009
013
COM
CINSP
014
016
SB 72-647
CINSP
006
007
008
009
002
003
009
SB 72-521
SB 72-647
SB 72-547
014
016
017
021
724204
Snecma | All rights reserved 11/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
WELD REPAIR AND RESIZING WITHOUT THE LUG RING
REPLACEMENT
BOLT HOLE DRILLING REPAIR
INSTALLATION OF THE LUG RING
REMOVAL OF THE COMBUSTION CHAMBER OUTER LINER
LUG RING
APPLY OF THE THERMAL BARRIER COATING
REMOVAL OF THE THERMAL BARRIER COATING
REPAIR OF THE PLASMA SPRAY WEAR COATING
22934 WELDED PATCH REPAIR +1 491
22935 INCO 718 PLASMA SPRAY REPAIR OF THE LUG RING AFT
SURFACE
+1 570
22936 WELD REPAIR OF THE OUTER LINER SEAL +1 570
23829 AFT SUPPORT RING REPLACEMENT QUOTE
21155 SALVAGE REPAIR +18 732
23837 Labour Packages (complete units, only SAC)
HPT NOZZLE SEGMENTS
Chtellerault
2002M20G
19229 2080M35G Cleaning / Incoming inspection 7 158
FULL REPAIR
18768 FULL REPAIR INCLUDING PACH, SVPA AND TBC +21 +3 198
22463 Rework of HPT Nozzles to Double Vertical Seal Slot Configuration +42 +13 824
SPLIT VANE REPAIR (3D-AERO)
19228 COOLING MODIFICATION +7 +134
HPT OUTER STATIONARY SEAL
Chtellerault
1808M58Gxx
12287 Cleaning / Incoming inspection 21 578
12288 HONEYCOMB REPLACEMENT ON HPT AFT OUTER
STATIONARY SEAL
+6 400
22274 DIAMETER B DIMENSIONAL RESTORATION BY PLASMA +2 888
HPT ROTOR BLADES
Chtellerault
2002M52P04
21735 2002M52P05 CLEANING / INSPECTION 5 78
2002M52P09
23470 2002M52P11 ECI edge of contact 30
11910 SWET WELD REPAIR ON TIP, AND DEEP TIP
CRACKS,RECONTOUR,EDM PLUGGED HOLES
+35 +804
FULL REPAIR
13708 THROUGH FIELD REWORK (PN 2002M52P09/11) +56 +1 308
FULL REPAIR with TBC (MONO RENE N5 MATERIAL)
REJUVENATION REPAIR
18390 HIGH PRESSURE TURBINE BLADE COATING REJUVENATION +56 +1 308
HPT FRONT ROTATING AIR
SEAL (FOS) Chtellerault
1795M36P02
22525 CLEANINIG / INCOMING INSPECTION 28 1006
11428 FPI +1 414
21402 REPAIR OF THE SEAL TOOTH COATING +2 204
21403 REPAIR OF DIAMETER R +1 667
HPT ROTOR FRONT SHAFT
Chtellerault
1873M73P01
12694 Cleaning / Incoming inspection 7 952
13934 THERMAL SPRAY RABBET REPAIR +21 +4 343
HPT ROTOR REAR SHAFT
Chtellerault
1498M45P06
008
002
003
004
005
012
006
007
CINSP
003
COM
CINSP
015
SB 72-0683
004
CINSP
CINSP
019
725201
SB 72-0389
020
021
CINSP
725203
AD 2002-13-03
001
002
CINSP
725204
001
725205
725101
725105
017
SB 72-0466
013
015
018
SAL
Snecma | All rights reserved 12/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
19995 1864M9P04 Cleaning / Incoming inspection 1608
70-21-11 STANDARD REPAIR
20469 70-21-12 REPLACEMENT OF THE SEAL TEETH +28 +7 251
70-21-31
70-21-32
REAR SHAFT BEARING JOURNAL THERMAL SPRAY REPAIR
70-21-33
18298 70-32-14 REPAIR OF AREA M +2 613
70-32-24
23118 70-41-11 REPLACEMENT OF THE SEAL TEETH +12 336
70-53-11
72-00-52 REPAIR OF AREA M
REAR SHAFT BEARING JOURNAL THERMAL SPRAY REPAIR
22685 SP 0704111(BLENDING OF ROTATING SEAL) +362
HPT REAR ROTATING SEAL
Chtellerault
1319M17P01
13128 1319M17P02 Cleaning / Incoming inspection 7 814
STANDARD REPAIR
19324 REPLACEMENT OF SEAL THEETH COATING +21 +5 786
THERMAL SPRAY REPAIR OF DIAMETER "E"
22166 MOUNTING FLANGE HOLE DAMAGE REPAIR +987
HPT SHROUD
Chtellerault
1522M25P02
20468 1795M50P01 Cleaning / Incoming inspection 7 68
1795M50P02
24008 1957M75P01 Standard repair of N5 material +35 +760
1957M91P02
24009 2081M28P01 Enhanced Durability Puck Repair +35 +760
2081M28P02 STANDARD REPAIR + SB C CLIP
11567 STANDARD REPAIR OF N5 MATERIAL +21 +746
C-CLIP COOLING MODIFICATION
STANDARD REPAIR ( post C CLIP)
22667 STANDARD REPAIR OF N5 MATERIAL SHROUD WITH C-CLIP
MODIFICATION
+21 +641
23475 Wear track & forward pad weld restoration +214
HPT SHROUD NOZZLE
SUPPORT ASSEMBLY Chtellerault
1784M36G01
22174 2002M69G02 Cleaning / Incoming inspection 28 1224
13628 FORWARD FLANGE WEAR REPAIR +8 474
13629 REPLACEMENT OF SUPPORT BUSHINGS +2 846
22089 REPLACEMENT OF THE BORESCOPE BOSS +2 027
21611 SELF RETAINING SLABBED HEAD BOLT REPLACEMENT +12 768
22335 SUPPORT AFT FLANGE HEADLESS STRAIGHT PIN
RELACEMENT
+767
23020 Dimensional heat-treat repair with mandels +3 140
13630 REPAIR OF WEAR ON VANES MOUNT AFT FACE +2 552
20559 FORWARD FLANGE DIMENSIONAL REPAIR +3 481
13631 PLASMA SPRAY OF SURFACE AM AND DIAMETER FM +4 095
21636 FORWARD FLANGE WEAR REPAIR +8 474
23119 REPLACEMENT OF SUPPORT BUSHINGS QUOTE
FORWARD FLANGE WEAR REPAIR
FORWARD FLANGE DIMENSIONAL REPAIR
SELF RETAINING SLABBED HEAD BOLT REPLACEMENT
HPT SHROUD SUPPORT
HANGER Chtellerault
1808M61
20200 1957M74 Cleaning / Incoming inspection 7 100
FULL REPAIR
13848 REPAIR USING RBD +21 +1 266
FULL REPAIR + SB
13983 REPAIR USING RBD +21 +1 591
CINSP
001
005
006
001
005
006
SP SP704111
CINSP
001
003
725210
002
CINSP
013
SB 72-0735
725301
011
SB 72-0079
003
R03,R11
CINSP
004
012
013
014
015
016
018
019
021
SB 72-0156
012
014
019
SB 72-0156
CINSP
014
014
725302
725304
Snecma | All rights reserved 13/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
C-CLIP COOLING MODIFICATION
23359 Form repair +294
LPT NOZZLE SEGMENTS STG 1
Chtellerault
338-108-606-0
11945 338-108-607-0 Cleaning / Incoming inspection 7 105
338-108-608-0 MINOR REPAIR 1
22514 338-108-609-0 BLEND REPAIR OF THE BLADE AIRFOIL +21 +263
338-108-706-0
338-108-707-0 VPA Overcoating
338-108-708-0 MINOR REPAIR 2
19029 338-108-709-0 BLEND REPAIR OF THE BLADE AIRFOIL +21 +483
RECONDITIONING OF VAPOR PHASE ALUMINIZATION
FULL REPAIR
20879 RECONDITIONING OF VAPOR PHASE ALUMINIZATION +28 +2 888
DIFFUSION BRAZING REPAIR
HEAVY REPAIR
19031 RECONDITIONING OF VAPOR PHASE ALUMINIZATION +28 +3 429
GAS PATH AREA RECONDITIONNING BY RBD
DIFFUSION BRAZING REPAIR
11948 COOLING MODIFICATION +226
LPT NOZZLE REAR FLANGE
STAGE 1 Saint Quentin
338-111-303-0
23529 Cleaning / Inspection 840
20374 REPLACEMENT OF THE PLASMA THERMAL COATING ON THE
FACE MATING WITH THE STAGE 1 LPT NOZZLE SEGMENT
+21 +4 515
INTERMEDIATE FLANGE
Chtellerault
23591 CLEANING / INSPECTION 7 420
21715 REPAIR OF THE THERMAL COATING ON MATING FACE AND
RABBET DIAMETER WITH STAGE 1 LPT NOZZLE INNER AIR
SEAL
+21 +3 366
LPT BLADES STAGE 1
Chtellerault
338-108-206-0
23615 Cleaning / Incoming inspection 7 16
STANDARD REPAIR
23616 TOUCH UP OF ALUMINIZATION ON STAGE 1 TURBINE
BLADES
+20 +100
Repair of Hard Facing and if necessary, the Mating Faces of Tip
Shroud on the Stage 1 Blades with Coast Metal 64
Repair of the Seal Teeth on the Blade Tip Shroud, by Weld Buildup
with Coast Metal 64
Repair of the Seal Teeth by Plasma Spraying
Resetting of Pretwist Angle
AIRFOIL BLEND REPAIR
23617 Repair of the Vapor-Phase Aluminization +21
LPT BLADES STAGES 2-4
Chtellerault
338 116-303-0
11578 338-108-304-0 Clean and serviceability inspection 7 16
338-108-403-0 STAGE 2 - STANDARD REPAIR
23654 338-108-503-0 REPAIR OF THE SEAL TEETH BY PLASMA SPRAYING +20 +100
338-108-504-0
338-108-553-0 Repair of the Vapor-Phase Aluminization on the Stage 2 Blades
338-108-5540
338-115-902-0 TOUCH-UP OF ALUMINIZATION ON STAGE 2
338-116-102-0
338-116-103-0
REPAIR OF HARD FACING AND MATING FACES ON TIP
SHROUD WITH CM 64 STAGE 2
338-116-152-0
338-116-153-0 AIRFOIL BLEND REPAIR
RESETTING OF PRETWIST ANGLE
STAGE 2
23657 Repair the seal teeth on the blade tip shroud by weld build up with
coast metal 64
+21
STAGE 3 - STANDARD REPAIR
001
SB 72-0079
016
CINSP
005
005
017
005
002
CINSP
001
CINSP
725311
725401
001
002
003
004
005
007
008
CINSP
002
003
004
006
010
018
725402
020
725306
725308
017
018
SB 72-0089
CINSP
001
055
Snecma | All rights reserved 14/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
23655 REPAIR OF THE SEAL TEETH BY PLASMA SPRAYING +20 +100
Repair of the stage 3 and stage 4 turbine blades seal teeth by weld
build-up with coast metal 64
REPAIR OF HARD FACING ON NOTCHES/MATING FACES ON
TIP SRHOUD
AIRFOIL BLEND REPAIR
RESETTING OF PRETWIST ANGLE
STAGE 4 - STANDARD REPAIR
23656 REPAIR OF THE SEAL TEETH BY PLASMA SPRAYING +20 +100
Repair of the stage 3 and stage 4 turbine blades seal teeth by weld
build-up with coast metal 64
REPAIR OF HARD FACING ON NOTCHES & MATING FACES
ON TIP SHROUD
REPAIR OF HARD FACING ON NOTCHES & MATING FACES
ON TIP SHROUD
AIRFOIL BLEND REPAIR
RESETTING OF PRETWIST ANGLE
STAGE 3 AND 4
23658 Removal of Oxides and Oxysulfides by Chemical Cleaning +21
LPT DISKS STAGE 1-4
Chtellerault - PTI
336-001-804-0
22526 Cleaning / Incoming inspection 21 1183
22785 Machining foward flange of stage 1 and 2 +4 300
12579 AD 2002-13-03 +645
13760 Blending according SPM 70-41-11 +2 150
LPT ROTOR SUPPORT
Chtellerault
725405
13157 CLEANING / INSPECTION 21 1022
CLEANING + FPI
STANDARD REPAIR
23571 REPAIR SURFACE MATING WITH LPT FWD ROT. OIL SEAL +4 515
RECOND REAR SURFACE MATING WITH FWD ROT. AIR SEAL
LPT ROTATING AIR SEALS
STAGE 1-4 Chtellerault
338-111-502-0
12449 338-111-603-0 Cleaning / Incoming inspection 21 504
338-111-701-0
12450 REPAIR OF THE TITANIUM/ALUMINIUM OXIDE COATING ON
THE SEAL TEETH
+2 673
STAGE 1 TO 4
18772 RECONDITIONING OF RETAINING RING MATING FACE +3 035
22179 TOUCH-UP OF SEAL TEETH QUOTE
REPAIR OF SEAL TEETH BY WELD BUILD-UP
LPT CASE
PTI
338-117-404-0
21850 REPLACEMENT OF RIVETED PARTS AND RIVETS +2 187
21777 REIDENTIFICATION PER SB72-0552 +825
23869 Repair of wear marks on rail 0 support ring by plasma spaying QUOTE
Rework of the LPT Case Rail 0 Support Ring and Reidentification of
the LPT Case.
PACKAGE 1
18920 REPLACEMENT OF RIVETED PARTS AND RIVETS +80 QUOTE
REPAIR OF WEAR MARKS ON RAIL 0 BY PUSLED WELDING
BUILD-UP
RECONDITIONING OF THE DIA A BY PLASMA
LPT NOZZLE SEGMENTS STAGE
2 Chtellerault
338-109-106-0
13627 338-109-107-0 Cleaning / Incoming inspection 7 105
338-109-206-0 MINOR REPAIR
002
003
005
007
017
002
003
005
008
009
017
028
CINSP
001
AD .
725403
SP 704111
CINSP
AD 2002-13-03
001
725405
003
CINSP
001
002
725406
003
004
001
SB 72-0552
725407
021
SB 72-0718
001
002
012
CINSP
725408
Snecma | All rights reserved 15/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
22510 338-109-207-0 BLEND REPAIR OF THE BLADE AIRFOIL +14 +210
338-109-306-0
338-109-307-0 TOUCH-UP THE ALUMINIZATION
MEDIUM REPAIR
19214 BLEND REPAIR OF THE BLADE AIRFOIL +14 +630
REPLACEMENT OF THE ABRADABLE HONEYCOMB LINER
REPAIR OF THE VAPOR PHASE ALUMINIZATION
FULL REPAIR
20366 BLEND REPAIR OF THE BLADE AIRFOIL +21 +1 680
DIFFUSION BRAZING FULL REPAIR
REPLACEMENT OF THE ABRADABLE HONEYCOMB LINER
REPAIR OF THE VAPOR PHASE ALUMINIZATION
19216 REPAIR OF THE ANTI-ROTATION SLOTS AND HARD FACE
MATING SURFACES BY WELDING
+7 +447
11552 INNER PLATEFORM REWORK +7 +630
LPT OUTER STATIONARY AIR
SEALS STAGE 1 Chtellerault
338-112-603-0
13985 338-112-605-0 Cleaning / Incoming inspection 7 91
338-122-604-0 STAGE 1 - STANDARD REPAIR
22471 REPLACEMENT OF THE ABRADABLE HONEYCOMB LINER +21 +1 040
REPAIR OF WEAR ON LOCATING DOWEL
APPLICATION OF VAPOR PHASE ALUMINIZATION (S.V.P.A) ON
THE HONEYCOMB LINER ON THE STAGE 1 SEAL SEGMENT
STAGE 1 - MAJOR REPAIR
22247 REPLACEMENT OF THE ABRADABLE HONEYCOMB LINER +24 +1 491
REWORK OF STAGE 1 SEAL SEGMENT
REPAIR OF WEAR ON LOCATING DOWEL
APPLICATION OF VAPOR PHASE ALUMINIZATION (S.V.P.A) ON
THE HONEYCOMB LINER ON THE STAGE 1 SEAL SEGMENT
LPT OUTER STATIONARY AIR
SEALS STAGE 2-4 Saint Quentin
338-112-602-0 STAGE 2-4
23949 338-112-7XX Serviceability inspection only 45
338-112-8XX STAGE 2 - STANDARD REPAIR
23950 Replace honeycomb +21 +435
STAGE 2
23951 Replace FWD braze strip QUOTE
STAGE 2
23952 Anti-rotation lock replacement QUOTE
STAGE3 - STANDARD REPAIR
23953 Clean and Serviceability inspection 28 435
Replace honeycomb
STAGE 3
23954 Replace FWD braze strip QUOTE
STAGE 4 - STANDARD REPAIR
23955 Replace honeycomb +28 +435
STAGE 4
23956 Anti-rotation Lock replacement QUOTE
LPT NOZZLE SEGMENTS STAGE
3 Chtellerault
338-109-702-0
11573 338-109-704-0 Cleaning / Incoming inspection 7 105
338-109-705-0 MINOR REPAIR
22536 338-109-802-0 VANE AIRFOIL BLEND REPAIR +14 +289
338-109-804-0
338-109-805-0 TOUCH-UP THE ALUMINIZATION
MEDIUM REPAIR
22537 VANE AIRFOIL BLEND REPAIR +21 +861
REPLACEMENT OF THE HONEYCOMB LINER
APVS - RECONDITIONING OF THE VAPOR PHASE
ALUMINIZATION
MAJOR REPAIR
20201 VANE AIRFOIL BLEND REPAIR +21 +1 728
REPLACEMENT OF THE HONEYCOMB LINER
APVS - RECONDITIONING OF THE VAPOR PHASE
ALUMINIZATION
001
005
001
004
018
001
004
018
020
019
SB 72-0241
CINSP
001
006
007
001
006
007
SB 72-0567
CINSP
001
004
008
CINSP
001
004
001
004_STG4
CINSP
001
002
001
005
009
001
005
009
725412
725412
725413
Snecma | All rights reserved 16/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
REPAIR OF CRACKS BY DIFFUSION BRAZING
21392 REPAIR OF THE ANTI-ROTATION SLOT AND HARD-FACE
MATING SURFACES BY WELDING
+7 +447
11575 INNER PLATEFORM REWORK +7 +363
LPT NOZZLE SEGMENTS STAGE
4 Chtellerault
338-110-102-0
21393 338-110-103-0 Cleaning / Incoming inspection 7 158
338-110-202-0 MINOR REPAIR
19137 338-110-203-0 Vane airfoil blend repair +14 +473
Replacement of the honeycomb liner
FULL REPAIR
19138 Vane airfoil blend repair +28 +1 166
Replacement of the honeycomb liner
Repair of cracks by diffusion brazing
19136 Repair of the anti-rotation slot and hard-face mating surfaces by
welding
+7 +420
SEAL SUPPORT
Chtellerault
336-026-302-0
21693 Cleaning / Incoming inspection 7 620
21694 REPLACEMENT OF THE ABRADABLE HONEYCOMB +21 +5 271
21793 REPAIR OF THE ABRADABLE COATING +3 019
21794 REPAIR OF THE OUTER DIAMETER MATING THE LPT ROTOR
SUPPORT, BY PLASMA SPRAYING
+2 946
21795 REPAIR OF THE INNER DIAMETER MATING THE LPT ROTOR
SUPPORT, BY PLASMA SPRAYING
+3 035
LPT SHAFT
PTI
340-074-703-0
19962 Cleaning / Incoming inspection 28 592
19964 FULL REPAIR OF THE ALUMINIUM PAINT +2 833
22345 REPAIR OF THE AFT DIAMETER, LOCATES THE FAN SHAFT
BY PLASMA SPRAYING
+3 817
22799 Reconditioning of the N4 bearing mating face +3 505
22800 Reconditioning of the rear rotating air/oil seal locating diameter +2 226
22801 Reconditioning of LPT stub shaft mating face +2 226
22802 REPAIR OF THE TUNGSTEN CARBIDE COATING ON
DIAMETER THAT LOCATES THE N4 BEARING
+4 730
22804 Reconditioning of forward locating diameter with fan shaft by metal
coating
+3 505
22803 REPAIR OF THE TUNGSTEN CARBIDE COATING ON
DIAMETER THAT LOCATES THE N5 BEARING
+3 951
22805 Reconditioning of center vent tube aft locating diameter +2 258
22806 Reconditioning of LPT stub shaft locating diameter on LPT shaft +2 226
22807 REPAIR OF CENTER VENT TUBE FORWARD LOCATING
DIAMETER
+2 580
22808 Reconditioning of rear rotating air seal locating diameter +2 365
22809 Replacement of bonded ribs +2 226
19963 IT76/96 - R01 - TOUCH UP OF THE ALUMINIUM PAINT +1 301
13164 CLEANING + MPI +1 962
REAR ROTATING AIR/OIL SEAL
Chtellerault
336-095-401-0
13738 Cleaning / Incoming inspection 28 648
11976 RECONDITIONING OF THE DIAMETER THAT LOCATES THE
LPT ROTOR SUPPORT BY PLASMA SPRAYING
+1 908
11977 REPAIR OF THE REAR ROTATING AIR /OIL SEAL TEETH +5 419
003
012
SB 72-0241
CINSP
001
009
725413
001
003
009
012
CINSP
001
002
003
004
CINSP
001
002
003
004
005
006
007
008
009
010
011
012
013
IT76/96
725504
AD 2002-13-03
CINSP
001
003
725416
725501
Snecma | All rights reserved 17/18
Effective : 01 Janv 2010
CFM56-7
Package Component / Parts ATA/Repair
Number
Workscope Repair Site TAT
in days
Price
CENTER VENT TUBE
PTI
301-319-724-0
23495 334-007-196-0 Cleaning / Inspection 21 471
Standard repair
17740 RECONDITIONING OF FRONT AND/OR MID JOURNALS +5 748
REPLACEMENT OF CENTER SECTION
RECONDITIONING OF AFT JOURNAL
21087 RECONDITIONING OF FRONT AND/OR MID JOURNALS +1 777
21086 RECONDITIONING OF AFT JOURNAL +1 568
21083 REPLACEMENT OF CENTER SECTION +2 822
17071 REPLACEMENT OF MID JOURNAL SECTION +2 508
17073 REPLACEMENT OF FORWARD SECTION (IN CONJUCTION
WITH REP 003 )
+1 902
21088 REPAIR OF THE LOCATING HOLES +1 401
18068 Recond. of aft. locating diameter +2 195
23493 Repair of the Anti-rotation Tang by Weld Build-Up +2 258
22470 CLEANING AND CONDITIONING +418
23161 REIDENTIFICATION SUIVANT SB 72-0124 +2 822
21707 REWORK OF ANTI-ROTATING TANG +2 090
22966 Any combination of repairs do not exceed 28 days
REAR VENT TUBE
PTI
23531 Cleaning / Inspection 7 366
23542 REPLACEMENT OF ONE OR SEVERAL LOCATING PINS +14 +784
NO. 4 BEARING FORWARD
ROTATING OIL SEAL Chtellerault
336-009-801-0
21599 Cleaning / Incoming inspection 21 523
22278 PLASMA SPRAY REPAIR DIAMETER C +1 542
22279 PLASMA SPRAY REPAIR DIAMETER X +1 239
12413 RECONDITIONING OF THE ABRADABLE COATING +2 242
21600 REPAIR OF RABBET DIAMETER (DIA A) +2 185
LPT SHAFT PLUG ASSEMBLY
PTI
23537 Cleaning / Inspection 7 314
CINSP
001
002
003
001
002
003
004
005
006
007
008
009
SB 72-0124
15-93902
COM
CINSP
001
CINSP
PLASM
PLASM2
001
002
CINSP
725506
725510
725514
725516
Snecma | All rights reserved 18/18