Sei sulla pagina 1di 12

1.50 1.

47
SL NO DESCRIPTION NOTATION FORMULA UNIT VALUE REMARKS
1.0 NOTATIONS
1.1 Flange Rigidity J =(52.14 * VL * Mo)/(L*E*go^2*KL*ho) <=1.0
where
1.2 Rigidity Index <= 1 J
1.3 Factor for loose type flange (from fig. 2-7.5) VL 0.60
1.4 Total moment acting on the flange Mo
1.5 L
1.6 Modulus of elasticity for the flage maeerial at design condition E
1.7 go 0.62
1.8 Rigidity factor for loose type flange KL refer para 2-14 page 368 0.20
1.9 ho 3.88
1.10
1.11
1.12
1.13
1.14
Thickness of hub at the small end go in 0.62
thickness of hub at back of flange g1 in 0.93
hub length h in 2.49
1.15 factor ho =sqrt(B*go) in 3.88
inside diameter of the flange B in 24.25
CHECK B<20g1 18.50
therefore B = 24.25
1.16
1.17
1.18 g1/go 1.49
1.19 h/ho 0.64
Calculation for Mo
1.20 Mo =W * (C-G) / 2
1.21 where
1.22 flange design bolt load for gasket seating W =Wm1
1.23 flange design bolt load for operating condition W =(Am+Ab) * Sa / 2
1.24 bolt circle diameter C in 32.00
1.25 Diameter at location of Gasket load reaction G refer sketch 1 fig 2-4 in 24.65
1.26
1.27 Calculation for Wm1
1.28 Wm1 =(0.785 * G^2 * P)+(2*b*3.14*G*m*P) lb 69138.33
DESIGN OF FABRICATED FLANGES
AS PER ASME SEC VIII DIVISION-1 APPENDIX -2 (2007)
1.50 1.47
SL NO DESCRIPTION NOTATION FORMULA UNIT VALUE REMARKS
DESIGN OF FABRICATED FLANGES
AS PER ASME SEC VIII DIVISION-1 APPENDIX -2 (2007)
1.29 where
1.30 Diameter at location of Gasket load reaction G refer sketch 1 fig 2-4 in 24.65
1.31 Internal Design Pressure P psi 145.00
1.32 b
1.33 gasket factor form table 2-5.1 m 0.00
1.34
1.35
1.36
1.37
1.38
1.39
1.40
1.41
1.42
1.43
1.44
1.45
1.46
1.47
1.48
1.49
1.50
1.51
1.52
1.53
1.54
1.55
1.56
1.57
1.58
1.59
1.60
1.61
1.62
2.0
2.1
3.0
3.1
1.50 1.47
SL NO DESCRIPTION NOTATION FORMULA UNIT VALUE REMARKS
DESIGN OF FABRICATED FLANGES
AS PER ASME SEC VIII DIVISION-1 APPENDIX -2 (2007)
1.50 1.47
SL NO DESCRIPTION NOTATION FORMULA UNIT VALUE REMARKS
DESIGN OF FABRICATED FLANGES
AS PER ASME SEC VIII DIVISION-1 APPENDIX -2 (2007)
1.50 1.42
SL NO DESCRIPTION NOTATION FORMULA UNIT VALUE REMARKS
1.0 NOTATIONS
1.1 Flange Rigidity J =(52.14 * VL * Mo)/(L*E*go^2*KL*ho) <=1.0 1.95 max
0.31 min
where
1.2 Rigidity Index <= 1 J
1.3 Factor for loose type flange (from fig. 2-7.5) VL 0.80
1.4 Total moment acting on the flange Mo max lb-in 3206925.32
min lb-in 513103.83
1.5 Factor L 1.23
1.6 Modulus of elasticity for the flage material at design condition E psi 29400000.00 temp=70F 28.8*10^6 for tem=200F
1.7 go in 1.30
1.8 Rigidity factor for loose type flange KL refer para 2-14 page 368 0.20
1.9 ho in 5.61
1.10
1.11
1.12
1.13
1.14
Thickness of hub at the small end go in 1.30
thickness of hub at back of flange g1 in 1.69
hub length h in 3.23
1.15 factor ho =sqrt(B*go) in 5.61
inside diameter of the flange B in 24.25 590
CHECK B<20g1 33.86 23.22835
therefore B = 24.25
1.16
1.17
1.18 g1/go 1.30
1.19 h/ho 0.58
Calculation for Mo
1.20 case 1 -for gasket seating Mo =W * (C-G) / 2 513103.83
case2 -for operating condition Mo =W * (C-G) / 2 3206925.32
1.21 where
1.22 flange design bolt load for gasket seating W =Wm1 lb 139537.87
1.23 flange design bolt load for operating condition W =(Am+Ab) * Sa / 2 lb 872118.88 780119.64
1.24 bolt circle diameter C in 32.00
1.25 Diameter at location of Gasket load reaction G refer sketch 1 fig 2-4 in 24.65
1.26
DESIGN OF FABRICATED FLANGES
AS PER ASME SEC VIII DIVISION-1 APPENDIX -2 (2007)
1.50 1.42
SL NO DESCRIPTION NOTATION FORMULA UNIT VALUE REMARKS
DESIGN OF FABRICATED FLANGES
AS PER ASME SEC VIII DIVISION-1 APPENDIX -2 (2007)
1.27 Calculation for Wm1
1.28 Wm1 =(0.785 * G^2 * P)+(2*b*3.14*G*m*P) lb 139537.87 139537.8725
1.29 where
1.30 Diameter at location of Gasket load reaction G refer sketch 1 fig 2-4 in 24.65
1.31 Internal Design Pressure P psi 145.00
1.32 b =0.5sqrt(b0) 0.57
1.33 gasket factor form table 2-5.1 m 5.50
1.34 basic gasket seating width bo =N/2 in 1.30
1.35 N in 2.60
1.36
1.37 Am in^2 31.78
1.38 Ab in^2 37.99
1.39 Sa,Sb psi 25000.00
1.40
1.41 Am1 =Wm1/Sb in^2 5.58
1.42 Am2 =Wm2/Sa in^2 31.78 86
1.43 43
1.44 Wm2 =3.14*b*G*y lb 794477.58 794477.5831 1.692913
1.45
1.46 82.1
1.47 where
1.48 gasket factor form table 2-5.1 y psi 18000.00
1.49
1.50
1.51
1.52 calculation of L L =((t*e+1)/T)+(t^3/d) 1.23
1.53
1.54 Flange thickness t 2.75
1.55 factor e =FL/ho 0.25
1.56 factor for loose type flange see fig2-7.4 FL 1.40
factor ho =sqrt(B*go) 5.61
1.57 factor involving K (ffrom fig 2-7.1) T 1.80
1.58 OD of Flange A in 35.98
1.59 As per fig.2.4 -(1) - dimension of flange B in 24.25
1.60 K =A/B 1.48
1.61 factor d =U/VL *ho * go^2 71.06
1.62 factor involving K (ffrom fig 2-7.1) U 6.00
Factor for loose type flange (from fig. 2-7.5) | 0.80
2.0
2.1
1.50 1.42
SL NO DESCRIPTION NOTATION FORMULA UNIT VALUE REMARKS
DESIGN OF FABRICATED FLANGES
AS PER ASME SEC VIII DIVISION-1 APPENDIX -2 (2007)
3.0
3.1
1.50 1.42
SL NO DESCRIPTION NOTATION FORMULA UNIT VALUE REMARKS
DESIGN OF FABRICATED FLANGES
AS PER ASME SEC VIII DIVISION-1 APPENDIX -2 (2007)
28.8*10^6 for tem=200F

Potrebbero piacerti anche