Sei sulla pagina 1di 8

LABORATORIO DE MEDIDAS I

DETERMINACION DEL ANGULO DE PERDIDAS Y EL FACTOR DE


PERDIDAS DE UN CONDENSADOR
INFORME FINAL
DESARROLLO DEL LABORATORIO
A.-

Armar el circuito de la figura A.


R1
A

220V
60Hz

1.-

Colocar R1 al mximo valor.


Rmax 690 ohms.

2.-

Regular la salida del autotransformador desde cero hasta 22OV, tomando como mnimo un juego de
15 valores de V, A, W, VR1 y VC.
TABLA DE VALORES REALES NO1

3.-

15.25

0.020

0.40

14.80

30.40

0.040

1.40

26.10

5.35
9.82

45.40

0.060

2.20

38.83

14.63

60.70

0.080

3.80

52.20

19.65

75.80

0.110

7.20

70.70

26.56

90.60

0.130

10.20

84.10

31.67

105.10

0.150

13.80

97.80

36.81

120.20

0.170

18.20

111.50

42.10

135.20

0.195

23.00

125.80

47.30

10

150.00

0.215

28.60

140.00

52.50

11

165.30

0.235

34.40

153.40

57.60

12

180.60

0.260

41.40

168.20

63.10

13

190.50

0.275

45.00

177.40

66.60

14

200.30

0.290

50.00

186.60

70.00

15

210.00

0.300

55.00

194.30

72.90

16

220.30

0.315

61.00

205.20

77.00

Determinar los errores tericos experimentales tabulados dando el error absoluto y relativo
porcentual.

Para ello se desarrolla: R1 = 690 ohms , C = 10.00 uF donde

Xc = 265.26 ohms
Z = (R12 + Xc2)

= (6902 + 265.262)

Z = 739.23 ohms
I=V/Z

W = R I2

Vr1 = R . I

TABLA DE VALORES TEORICOS NO1


Dato

V
(Volt)

A
(mA)

W
(Watts)

VR1
(Volt)

VC
(Volt)

15.25

0.021

0.3

14.23

5.47

30.40

0.041

1.2

28.38

10.91

45.40

0.061

2.6

42.38

16.29

60.70

0.082

4.7

56.66

21.78

75.80

0.103

7.3

70.75

27.20

90.60

0.123

10.4

84.57

32.51

105.10

0.142

13.9

98.10

37.71

120.20

0.163

18.2

112.20

43.13

135.20

0.183

23.1

126.20

48.51

10

150.00

0.203

28.4

140.01

53.82

11

165.30

0.224

34.5

154.29

59.32

12

180.60

0.244

41.2

168.57

64.81

13

190.50

0.258

45.8

177.81

68.36

14

200.30

0.271

50.7

186.96

71.87

15

210.00

0.284

55.7

196.01

75.35

16

220.30

0.298

61.3

205.63

79.05

ERROR ABSOLUTO = V(terico) - V(real)


ERROR RELATIVO = E( abs ) / V (terico)
TABLA DE ERRORES ABSOLUTOS Y RELATIVOS NO1
A
Dato

Error
Absol.

Error
Relat.

Error
Absol.

VR

Error
Relat.

Error
Absol.

VC

Error
Relat.

Error
Absol.

Error
Relat.

0.00

3.1%

0.11

36.2%

0.57

4.0%

0.12

2.2%

0.00

2.7%

0.23

20.0%

2.28

8.0%

1.09

10.0%

0.00

2.3%

0.40

15.5%

3.55

8.4%

1.66

10.2%

0.00

2.6%

0.85

18.3%

4.46

7.9%

2.13

9.8%

0.01

7.3%

0.05

0.8%

0.05

0.1%

0.64

2.4%

0.01

6.1%

0.16

1.6%

0.47

0.6%

0.84

2.6%

0.01

5.5%

0.15

1.1%

0.30

0.3%

0.90

2.4%

0.01

4.6%

0.04

0.2%

0.70

0.6%

1.03

2.4%

0.01

6.6%

0.08

0.3%

0.40

0.3%

1.21

2.5%

10

0.01

6.0%

0.19

0.7%

0.01

0.0%

1.32

2.5%

11

0.01

5.1%

0.10

0.3%

0.89

0.6%

1.72

2.9%

12

0.02

6.4%

0.22

0.5%

0.37

0.2%

1.71

2.6%

13

0.02

6.7%

0.82

1.8%

0.41

0.2%

1.76

2.6%

14

0.02

7.0%

0.66

1.3%

0.36

0.2%

1.87

2.6%

15

0.02

5.6%

0.68

1.2%

1.71

0.9%

2.45

3.3%

16

0.02

5.7%

0.28

0.5%

0.43

0.2%

2.05

2.6%

4.-

Manteniendo en el voltmetro V y una tensin constante de 22OV, regular la resistencia R 1


desde un valor mximo al valor mnimo y tomar un juego de 15 valores de V,A, W, VR1 y VC.

Tensin Constante: V = 22O Voltios


TABLA DE VALORES REALES No. O2

Dato

5.-

V
(Volt)

A
(mA)

W
(Watts)

VR1
(Volt)

VC
(Volt)

220

0.315

61.0

204.5

76.6

220

0.340

65.0

200.8

83.8

220

0.355

67.0

199.6

86.6

220

0.415

77.0

191.0

103.7

220

0.480

85.0

180.7

120.8

220

0.510

88.0

175.0

128.8

220

0.530

89.0

170.6

134.8

220

0.580

91.0

160.1

146.3

220

0.620

91.4

150.4

156.4

10

220

0.644

90.0

141.0

164.3

11

220

0.680

87.0

130.3

172.8

12

220

0.700

86.0

119.8

180.5

13

220

0.730

79.0

109.8

187.4

14

220

0.750

75.0

100.4

191.8

15

220

0.770

69.0

89.7

196.8

16

220

0.840

1.4

0.0

217.7

Repetir el punto 4.

V = 22O Voltios ( es constante ) ; Xc = 265.26 ohms ; R1 = V / I


Z = (R12 + Xc2) ;

I = 22O / Z
TABLA DE VALORES TEORICOS N02

Dato

Z
(Ohm)

R1
(Ohm)

A
(Amp)

W
(Watts)

VR1
(Volt)

VC
(Volt)

649.21

592.542

0.339

74.6

200.8

89.9

647.06

590.188

0.340

74.8

200.7

90.2

619.72

560.078

0.355

78.1

198.8

94.2

530.12

458.982

0.415

91.3

190.5

110.1

458.33

373.773

0.480

105.6

179.4

127.3

431.37

340.176

0.510

112.2

173.5

135.3

415.09

319.281

0.530

116.6

169.2

140.6

379.31

271.134

0.580

127.6

157.3

153.9

354.84

235.685

0.620

136.4

146.1

164.5

10

341.61

215.262

0.644

141.7

138.6

170.8

11

323.53

185.225

0.680

149.6

126.0

180.4

12

314.29

168.561

0.700

154.0

118.0

185.7

13

301.37

143.042

0.730

160.6

104.4

193.6

14

293.33

125.226

0.750

165.0

93.9

198.9

15

285.71

106.159

0.770

169.4

81.7

204.3

16

261.90

372.769

0.840

184.8

220.0

222.8

ERROR ABSOLUTO = V(terico) - V(real)


ERROR RELATIVO = E( abs ) / V (terico)
TABLA DE ERRORES ABSOLUTOS Y RELATIVOS NO2

A
Dato

Error
Absol.

Error
Relat.

Error
Absol.

VR

Error
Relat.

Error
Absol.

VC

Error
Relat.

Error
Absol.

Error
Relat.

0.00

0.0%

3.11

4.8%

0.99

0.5%

6.96

8.3%

0.00

0.0%

3.23

4.7%

0.14

0.1%

6.39

7.1%

0.00

0.0%

3.58

5.1%

0.77

0.4%

7.57

8.0%

0.00

0.0%

2.05

2.6%

0.52

0.3%

6.38

5.8%

0.00

0.0%

1.12

1.3%

1.29

0.7%

6.52

5.1%

0.00

0.0%

0.48

0.5%

1.51

0.9%

6.48

4.8%

0.00

0.0%

0.69

0.8%

1.38

0.8%

5.79

4.1%

0.00

0.0%

0.21

0.2%

2.84

1.8%

7.55

4.9%

0.00

0.0%

0.80

0.9%

4.28

2.9%

8.06

4.9%

10

0.00

0.0%

0.72

0.8%

2.37

1.7%

6.53

3.8%

11

0.00

0.0%

1.35

1.6%

4.35

3.5%

7.58

4.2%

12

0.00

0.0%

3.41

4.1%

1.81

1.5%

5.18

2.8%

13

0.00

0.0%

2.77

3.6%

5.38

5.2%

6.24

3.2%

14

0.00

0.0%

4.56

6.5%

6.48

6.9%

7.14

3.6%

15
16

0.00

0.0%

6.06

9.6%

7.96

9.7%

7.45
-

3.6%
-

B.- Armar el circuito de la figura 2B

220V
60Hz

1.-

R2

La resistencia R2 ponerla al mximo valor.


RESISTENCIA MAXIMA 5 kilo Ohms.

2.-

Regular la salida del autotransformador variando la tensin desde cero hasta 22OV, tomando

como mnimo un juego de 15 valores de A, V, W, VR2 y VC.

TABLA DE VALORES REALES NO3

Dato

V
(Volt)

A
(mA)

W
(Watts)

15.02

0.057

0.00

30.04

0.115

0.20

45.50

0.175

0.40

60.00

0.235

0.80

75.00

0.295

1.20

90.00

0.350

1.80

105.00

0.410

2.40

120.00

0.470

3.20

135.00

0.530

4.00

10

150.00

0.580

5.00

11

165.00

0.640

6.08

12

180.00

0.700

7.20

13

195.00

0.760

8.48

14

210.00

0.820

10.00

15

220.10

0.860

10.80

SERIE
COS = _V2_-__Vr12__-__Vc2_
2 . Vr1 .VC
Tg = Ctg
TABLA DE ANGULO DE PERDIDA Y FACTOR DE PERDIDAS DE UN CONDENSADOR-TABLA No.O1
( CASO A: R1 (CONSTANTE) Y V (VARIABLE) )

Dato

COS f

Tag a

-0.0954

95.5

-0.0958

-5.47

0.2858

73.4

0.2983

16.61

0.2987

72.6

0.3130

17.38

0.2796

73.8

0.2912

16.23

0.0111

89.4

0.0111

0.64

0.0249

88.6

0.0249

1.43

0.0175

89.0

0.0175

1.00

0.0259

88.5

0.0259

1.49

0.0182

89.0

0.0182

1.04

10

0.0098

89.4

0.0098

0.56

11

0.0269

88.5

0.0269

1.54

12

0.0162

89.1

0.0162

0.93

13

0.0162

89.1

0.0162

0.93

14

0.0153

89.1

0.0153

0.88

15

0.0365

87.9

0.0365

2.09

16

0.0157

89.1

0.0157

0.90

TABLA DE ANGULO DE PERDIDA Y FACTOR DE PERDIDAS DE UN CONDENSADOR - TABLA


No.O2( CASO B: R1 (VARIABLE) Y V (CONSTANTE) )

Dato

COS f

Tag a

0.0227

88.7

0.0227

1.30

0.0314

88.2

0.0314

1.80

0.0307

88.2

0.0307

1.76

0.0294

88.3

0.0294

1.69

0.0265

88.5

0.0265

1.52

0.0263

88.5

0.0263

1.51

0.0245

88.6

0.0245

1.40

0.0291

88.3

0.0291

1.67

0.0280

88.4

0.0280

1.61

10

0.0329

88.1

0.0329

1.89

11

0.0347

88.0

0.0347

1.99

12

0.0339

88.1

0.0340

1.94

13

0.0298

88.3

0.0298

1.71

14

0.0398

87.7

0.0398

2.28

15

0.0460

87.4

0.0460

2.64

16

PARALELO
COS = Pc / V I
COS = (I * Sen / Ic

TABLA DE ANGULO DE PERDIDA Y FACTOR DE PERDIDAS DE UN CONDENSADOR - TABLA No.O3


( CASO A: R1 (CONSTANTE) Y V (VARIABLE) )
Dato

COS f

Ic
(mA)

Cos a

0.0000

90.0

0.059

0.9633

15.57

0.0579

86.7

0.118

0.9701

14.04

0.0502

87.1

0.179

0.9751

12.82

0.0567

86.7

0.236

0.9926

6.97

0.0542

86.9

0.295

0.9970

4.46

0.0571

86.7

0.355

0.9855

9.75

0.0557

86.8

0.414

0.9896

8.25

0.0567

86.7

0.473

0.9926

6.97

0.0559

86.8

0.532

0.9950

5.73

10

0.0575

86.7

0.591

0.9799

11.51

11

0.0576

86.7

0.650

0.9830

10.59

12

0.0571

86.7

0.709

0.9855

9.75

13

0.0572

86.7

0.768

0.9877

8.99

14

0.0581

86.7

0.827

0.9895

8.31

15

0.0571

86.7

0.867

0.9902

8.02

CUESTIONARIO
1. Cul es la influencia de R1 en la determinacin del ngulo de prdidas y el factor de prdidas del
condensador utilizado?
Tangente de (tg ) es el factor de prdidas, tericamente depende en forma directamente proporcional a la
resistencia cuando se trata del primer circuito en que R1 est en serie con el capacitor

tg

IR1
2fR1C 0
I
C 0

Mientras que en el segundo circuito en que R est en paralelo la dependencia es inversamente proporcional,
segn :

tg

R2
1

VC 0 2fR 2 C 0

En la experiencia se pudo confirmar el primer caso (A) en que salvo los primeros valores el ngulo de
prdidas tuvo una tendencia a estabilizarse. Mientras que para el segundo caso (B) cuando disminuamos la
resistencia no vara en forma apreciable el ngulo de prdidas.
R1 hace que el condensador se comporte como un condensador real, o sea que el condensador tenga
prdidas debido a su aislante (dielctrico) que se representa como una resistencia (en este experimento se
simul la resistencia del dielctrico con una resistencia ya definida).
2.

Cul es la influencia de R 2 en la determinacin del ngulo de prdidas y el factor de prdidas del


condensador utilizado?
Esta influencia tericamente se puede apreciar en la segunda ecuacin ,vista en la repuesta anterior.
En la experiencia mantuvimos R2 constante mientras que varabamos la tensin .
Pudimos comprobar que efectivamente el factor de prdidas no vara mucho sino que se mantuvo
alrededor de 0.9.
Matenindose R2 constante a.5 K y aumentando la tensin, ocasiona un crecimiento de la corriente total,
teniendo presente que la impedancia del circuito es constante en todo momento, esto hace que el ngulo
de prdidas se mantenga casi constante aunque este influenciado con una tensin constante.

3.

Cul es la importancia del ngulo de prdidas y el factor de prdidas del condensador?


El factor de prdidas est relacionado directamente con el valor de las resistencias R 1 y R2 que representan
la resistencia del aislante o dielctrico del condensador. Al aumentar R, aumenta el factor de prdidas.
Entonces este nos indica las prdidas del mismo condensador, prdidas que se presentan en el aislante.
Luego el ngulo de prdidas nos indica la calidad del aislante del condensador usado.

4.

En condensadores normalizados, determinar el factor de prdidas y el ngulo de prdidas, tales


como; papel, aceite, papel impregnado en aceite, cermica, poliester.

CONSTANTES DIELECTRICAS

AIRE
RESINA
HULE DURO
PAPEL SECO
BAQUELITA
MICA
PORCELANA
MYCALEX
VIDRIO
COMPUESTOS DE DIOXIDO

1
2.5
2.8
3.5
4.5 a 7.5
5a9
5.5
8
4.2
90 a 170

DE TITANIO

RESISTENCIAS DIELECTRICAS
AIRE
FIBRA
VIDRIO
ACEITE DE RICINO
BAQUELITA
PORCELANA
PAPEL (PARAFINADO)
PAPEL (ENCERADO)
MICA

5.

80
50
200
370
500
750
1200
1800
200

Dar por lo menos 5 observaciones y conclusiones de carcter personal.


Existe una relacin directa entre el factor de prdidas y la resistencia del dielctrico del capacitor y a la vez
la relacin de corriente consumida por la resistencia.
Para el caso del experimento con la resistencia en serie y variando solo la tensin mas no la resistencia, el
ngulo de prdidas y el factor de prdidas solo sufre pequeas variaciones y el valor de los mismos son
pequeos.
En el segundo caso variando la resistencia y haciendo esta ms pequea el ngulo de prdidas tiende a
valores pequeos, lo cual indica una mejor calidad del aislante del condensador. En las tablas halladas no
se puede ver con claridad este hecho ya que la variacin de sta presenta una tendencia lineal. Adems los
errores en la medicin y lectura contribuyen a este inconveniente.
Entonces para determinar la exacta capacidad del capacitor se debe tener en cuenta la calidad del
dielctrico o aislante del mismo para que su factor de prdidas no sea considerable.
Tambin se puede deducir que un condensador sea ptimo debe tener un ngulo de prdida peque4.