GCT-1000 configuration.

0=End 1=Topogr. 2=Opt.


Topography editor.
0=End 1=Stations
2=Topography 3=Various
GCT-1000 configuration.
0=End 1=Topogr. 2=Opt.
***** GCT 1000 *****
Complete printout of all programmed variables:
-------------------------------------------------------
Programm version V3.53e 20.11.1997 14:10:18
Configuration of system OPTICAS KAUFFMAN VYMC
Date: 01.07.2014 17:02:54
Configuration of stations :
---------------------------
St-No. Status Prio. --1----2----3--- Adress-no. ----7----8----9---10
1 NORM 0 2000 0 0 0 0 0 0 0 0 0
2 NORM 0 1000 0 0 0 0 0 0 0 0 0
3 NORM 0 4000 0 0 0 0 0 0 0 0 0
4 NORM 0 3000 0 0 0 0 0 0 0 0 0
5 NORM 0 7000 0 0 0 0 0 0 0 0 0
6 NORM 0 5000 0 0 0 0 0 0 0 0 0
7 NORM 0 6000 0 0 0 0 0 0 0 0 0
Topography of system OPTICAS KAUFFMAN VYMC
Date: 01.07.2014 17:02:57
Starting from blower 1:
diverter 1.1 active position 1:
station 1
End of diverter.
diverter 1.1 active position 2:
station 2
End of diverter.
diverter 4.1 active position 1:
station 3
End of diverter.
diverter 4.1 active position 2:
station 4
End of diverter.
diverter 6.1 active position 1:
station 5
End of diverter.
diverter 6.1 active position 2:
station 6
End of diverter.
station 7
End.
Blower at following stations: 1
No. of digits for addresses : 4
Max. transport time sec.: 120
suction time for branch clearing sec.: 20
Blower-type (afterrun) : NO
Sending protokoll switched on : NO
Alarmrelais switched on : NO
Debug variable : 162
Change from suction to presssure delayed : 0
Sendingcounter : 1141792
deputy table of the system OPTICAS KAUFFMAN VYMC
Date: 01.07.2014 17:03:05
No deputy numbers stored.
Stat type d1 d2 cst.dst. timeout power absent slow
1 10 2 0 0 A 90 Off Off 0
2 10 2 0 0 A 40 Off Off 0
3 10 0 0 0 A 40 Off Off 0
4 10 2 0 0 A 40 Off Off 0
5 10 0 0 0 A 40 Off On 0
6 10 2 0 0 A 40 Off Off 0
7 10 0 0 0 A 90 Off Off 0
Master station is no. 7
Lost carrier goes to station Nr. 7
GCT-1000 configuration.
0=End 1=Topogr. 2=Opt.
GCT-1000 configuration.
0=End 1=Topogr. 2=Opt.
GCT-1000 configuration.
0=End 1=Topogr. 2=Opt.
GCT-1000 configuration.
0=End 1=Topogr. 2=Opt.
GCT-1000 configuration.
0=End 1=Topogr. 2=Opt.
GCT-1000 configuration.
0=End 1=Topogr. 2=Opt.
GCT-1000 configuration.
0=End 1=Topogr. 2=Opt.
End of configur. mode
----- Service mode -----
GCT-1000e
V3.53e 20.11.1997 14:10:18
01.07.2014 17:07:00 --- End of malfunction. Normal operating.
Order received: from 7 to 4
01.07.2014 17:07:39Blower: suction
01.07.2014 17:07:42 S 7 TSS
01.07.2014 17:07:46 S 6 TSd1
01.07.2014 17:07:53Blower: pressure
01.07.2014 17:07:53 S 4 TSd1
01.07.2014 17:07:57 S 4 TSd1
01.07.2014 17:08:04Blower: off
01.07.2014 17:08:05 S 4 TSS
01.07.2014 17:08:11 S 4 TSS
Order received: from 4 to 7
01.07.2014 17:09:27Blower: suction
01.07.2014 17:09:30 S 4 TSS
01.07.2014 17:09:35 S 4 TSd1
01.07.2014 17:09:39Blower: pressure
01.07.2014 17:09:44 S 4 TSd1
01.07.2014 17:09:49 S 6 TSd1
01.07.2014 17:09:55Blower: off
01.07.2014 17:09:56 S 7 TSS
01.07.2014 17:10:00 S 7 TSS
01.07.2014 17:12:29 --- End of malfunction. N