BS 6180:1999

(f)
C O
In addition, abarrier that is structurally safe should
not possess sufficient flexibility to alarmbuilding
users when subject to normal service conditions.
Therefore, for serviceability considerations, the
limiting condition for deflection appropriate for a
barrier for the protection of people is that the total
horizontal displacement of the barrier at any point
fromits original unloaded position should not
exceed the deflection limits determined fromthe
relevant structural design code for the material used
or 25mm, whichever is the smaller.
Where aglass component of abarrier is subjected to
imposed loads givenin BS6399-1, or if appropriate
BS6399-2, the displacement of any point of the glass
component, relative to its fixings, should not exceed
Ll65 or 25mm, whichever is the smaller where L is
given in8.3, 8.4 or 8.5.
Where the infill panel is aplastics material, as given
in11.4, the displacement of any point of the infill
panel should not exceed Ll80 or 25mm, whichever is
the smaller, when subjected to infill imposed loads
given inBS6399-1or, if appropriate, the wind loads
given inBS6399-2(where Lis the clear span of the
infill panel between supports).
6.4.2 Vehicle barriers
Barriers designed to resist vehicular impacts may be
distorted by such impacts but should remain
substantially inplace.
6.5Fixings, attachments and anchorage
C are should be taken to ensure that the strength of
fixings, attachments and anchorage securing the
barrier to asubstrate is adequate to sustain aloading
greater than that to which the barrier will be
subjected. All joints should be designed to provide
the full strength of the members being joined. To
that end, where any uncertainty exists with regard to
the strength of any component inthe fixing, the
design loading factors should be increased by 50%.
It is essential that fixing design takes particular
account of the material into which the fixing is
placed, the spacing between fixings, the edge
distance, and where the substrate is concrete, the
position of reinforcement. Reliance onthe pull-out
capacity of asingle fixing should be avoided.
NO TE 1 The recommendation of an additional load factor of 1.5
is intended to ensure that under an extreme load condition,
barriers will give an indication of failure by deflection distortion
and not by total collapse, as would be brought about by afailure
of the fixing, attachment or anchorage system.
NO TE 2 Where the design strength of aproposed system of
fixing to an existing substrate cannot be determined with
reasonable accuracy by theoretical consideration, load testing
should be used to validate the design. A factor greater than 1.5on
barrier load design may also be appropriate.
6.6Safety details
6.6.1 General
The finished barrier should have no sharp edges or
projections that may cause injury to persons or
damage to clothing.
Infill panels and balusters are intended to provide
support and protection to the user, and should be
designed to restrain people without causing
additional injury fromsharp edges, thin sections,
open ended tubes, projecting details, etc.
The ends of barriers on unlit access roads should be
provided with reflectors or reflective markings.
The designer should be aware of the need to provide
maintenance of the barrier to sustain levels of safety
and performance, C onsideration should be given in
the design of the barrier to the possibility of
tampering or vandalism.
6.6.2 Vehicle barriers
The designer should, wherever possible, avoid
introducing projections on the vehicular face of the
barrier and should also consider ways of redirecting
vehicles insuch away as to cause minimum damage
after impact.
6.7Support fromadjacent construction
The designer should ensure that any construction or
structure acting as support for barriers is of
adequate strength and stability to sustain all applied
loads safely without excessive stress, deflection or
distortion.
6.8Sight lines
It is essential to consider sight lines as well as safety
aspects when designing barriers inplaces such as
theatres, cinemas and concert halls. This applies
particularly to barriers protecting balconies or parts
of balconies having fixed seating within 530mmof
the barrier. The relationship between the height and
width of abarrier affects both sight lines and safety.
A lower, wider barrier may provide the same degree
of protection as ahigher, narrower barrier. The
minimum height for anarrow barrier given inTable 1
is800mm, however this height may be reduced to a
minimum of 750mmprovided the sumof the barrier
width and the barrier height is greater than 975mm
(see Figure 2).
NO TE It should be noted that where the barrier is not in front of
fixed seating (e.g. at the end of the gangway) the normal design
criteria apply.