Residential Electrical Inspections - FL Author: David Burtt
Residential Electrical Inspections - FL
Introduction Activity Start Your Day Activity Question 1: Start Your Day Question. Question ID#: 2827.0 Question 1: According to your handout, which of the following is one of the most common violations on a rough-in inspection?
A: 300.4(A) Nailplates. B: 110.7 Installation free from short circuits. C: 110.3(B) Staples installed correctly. D: 410.116 Recessed luminaire clearance. Question 2: Start Your Day Question. Question ID#: 2828.0 Question 2: According to your handout, which of the following is one of the most common violations on a FINAL inspection?
A: 230.66 Listed service equipment. B: 250.28 Main bonding jumper. C: 210.52 Improper location of receptacles. D: 110.14(B) Proper splices for equipment grounds. Question 3: Start Your Day Question. Question ID#: 2829.0 Question 3: Which of the following installations is a Code violation?
A: A permanently installed fire alarm system supplied by a non-GFCI protected outlet. B: A non-GFCI protected receptacle installed in a living room behind a sofa. C: A non-GFCI protected receptacle installed in a garage behind a freezer. D: A GFCI-protected receptacle installed outdoors 10 ft. away from an HVAC compressor. Question 4: Start Your Day Question. Question ID#: 2830.0 Question 4: In the morning, a coworker was asking you about a commercial job. According to 2011 NEC section 450.14, which of the following is now required to be marked on the transformer when the disconnecting means is not within sight?
Page 1 2013 JADE Learning, Inc. Residential Electrical Inspections - FL Author: David Burtt A: Location of the disconnecting means. B: Type of disconnecting means. C: Voltage of circuit. D: Location of the transformer. Question 5: Start Your Day Question. Question ID#: 2831.0 Question 5: According to 2011 NEC section 590.4(D), which of the following is true about old service pole receptacle covers?
A: They do not need to be replaced. B: They need to be replaced if installed before 2002. C: They need to be replaced with tamper-resistant type receptacle covers. D: They need to be replaced with the extra-duty type receptacle covers. Creekside Dr. Inspection - Temporary Service Activity Question 6: Creekside Dr. Inspection - Temporary Service Question. Question ID#: 2833.0 Question 6: Which of the following is true about your first inspection of the temporary service?
A: Approved. B: Disapproved for multiple violations. C: Disapproved for one violation. D: Not enough information to approve or disapprove. Question 7: Creekside Dr. Inspection - Temporary Service Question. Question ID#: 2834.0 Question 7: Which of the following sections of the 2011 NEC covers "Unused Openings" for a temporary service installation?
A: 110.12(A). B: 110.22(A). C: 200.6. D: 230.24. Question 8: Creekside Dr. Inspection - Temporary Service Question. Question ID#: 2835.0 Question 8: Which of the following sections of the 2011 NEC covers "Identification of Disconnecting Means" for the temporary service installation?
A: 110.12(A). B: 110.22(A). C: 200.6. D: 230.24. Page 2 2013 JADE Learning, Inc. Residential Electrical Inspections - FL Author: David Burtt Question 9: Creekside Dr. Inspection - Temporary Service Question. Question ID#: 2836.0 Question 9: Which of the following sections of the 2011 NEC covers clearances of overhead service conductors for the temporary service installation?
A: 200.6. B: 230.24. C: 230.42. D: 240.4. Question 10: Creekside Dr. Inspection - Temporary Service Question. Question ID#: 2837.0 Question 10: Which of the following sections of the 2011 NEC covers "Ground Rod Installation" for the temporary service installation?
A: 250.110. B: 250.25. C: 250.53(G). D: 250.92. Mill St. Inspection - Rough-In Inspection Activity Question 11: Mill St. Inspection - Rough-In Inspection Question. Question ID#: 2839.0 Question 11: Which of the following is true about your inspection on Mill St.? This was a rough-in inspection.
A: Approved. B: Disapproved for multiple violations. C: Disapproved for one violation. D: Not enough information to approve or disapprove. Question 12: Mill St. Inspection - Rough-In Inspection Question. Question ID#: 2840.0 Question 12: Which of the following sections of the 2011 NEC covers "Proper Location/Spacing of Receptacle Outlet(s) (Countertops)" for the rough-in inspection?
A: 210.52(C). B: 210.52(F). C: 210.52(H). D: 210.52(I). Question 13: Mill St. Inspection - Rough-In Inspection Question. Question ID#: 2841.0 Question 13: Which of the following sections of the 2011 NEC covers "Cables Stapled Flat" for the rough-in Page 3 2013 JADE Learning, Inc. Residential Electrical Inspections - FL Author: David Burtt inspection?
A: 334.23. B: 334.30. C: 334.40(A). D: 300.1. Question 14: Mill St. Inspection - Rough-In Inspection Question. Question ID#: 2842.0 Question 14: Which of the following sections of the 2011 NEC covers "Branch Circuits- Proper Rating for Location" for the rough-in inspection?
A: 210.11(A). B: 210.11(C). C: 210.52(F). D: 300.4(A)(1). Question 15: Mill St. Inspection - Rough-In Inspection Question. Question ID#: 2843.0 Question 15: Which of the following sections of the 2011 NEC covers "Closet Luminaire Clearance" for the rough-in inspection?
A: 410.10. B: 410.12. C: 410.16. D: 440.10. Pine St. Inspection - Rough-In Inspection Activity Question 16: Pine St. Inspection - Rough-In Inspection Question. Question ID#: 2845.0 Question 16: Which of the following is true about your inspection on Pine St.? This inspection was a rough-in inspection.
A: Approved. B: Disapproved for multiple violations. C: Disapproved for one violation. D: Not enough information to approve or disapprove. Question 17: Pine St. Inspection - Rough-In Inspection Question. Question ID#: 2846.0 Question 17: Which of the following sections of the 2011 NEC covers "Cable in Unfinished Basement/Crawl Space" for the rough-in installation?
A: 334.17. B: 334.27(C). Page 4 2013 JADE Learning, Inc. Residential Electrical Inspections - FL Author: David Burtt C: 334.23. D: 334.15(C). Question 18: Pine St. Inspection - Rough-In Inspection Question. Question ID#: 2847.0 Question 18: Which of the following sections of the 2011 NEC covers "Nail Plates Where Required" for the rough-in inspection?
A: 300.4(A)(1). B: 300.14. C: 334.30(A). D: 314.23. Question 19: Pine St. Inspection - Rough-In Inspection Question. Question ID#: 2848.0 Question 19: Which of the following sections of the 2011 NEC covers "Proper Splices for Equipment Grounds" for the rough-in inspection?
A: 110.3(B). B: 110.12. C: 110.14(B). D: 250.110. Question 20: Pine St. Inspection - Rough-In Inspection Question. Question ID#: 2849.0 Question 20: Which of the following sections of the 2011 NEC covers "Device/Outlet Box Required Cubic Inches" for the rough-in inspection?
A: 300.14. B: 314.4. C: 314.16. D: 314.27. Kenmore Ct. Inspection - Final Inspection Activity Question 21: Kenmore Ct. Inspection - Final Inspection Question. Question ID#: 2851.0 Question 21: Which of the following is true about your inspection on Kenmore Ct.? This was a final stage inspection.
A: Approved. B: Disapproved for multiple violations. C: Disapproved for one violation. D: Not enough information to approve or disapprove. Page 5 2013 JADE Learning, Inc. Residential Electrical Inspections - FL Author: David Burtt Question 22: Kenmore Ct. Inspection - Final Inspection Question. Question ID#: 2852.0 Question 22: Which of the following sections of the 2011 NEC covers "Branch Circuits - Proper Rating for Location" for the final inspection?
A: 210.11(C). B: 210.52(C). C: 210.50(C). D: 230.70(A)(1). Question 23: Kenmore Ct. Inspection - Final Inspection Question. Question ID#: 2853.0 Question 23: Which of the following sections of the 2011 NEC covers "Device Covers Seated Against Wall" for the final inspection?
A: 405.4. B: 406.5. C: 406.6. D: 408.4. Question 24: Kenmore Ct. Inspection - Final Inspection Question. Question ID#: 2854.0 Question 24: Which of the following sections of the 2011 NEC covers "Proper Location of Receptacle Outlet(s)" (Bathroom) for the final inspection?
A: 210.52(D). B: 210.11(C). C: 210.70. D: 210.52(I). Question 25: Kenmore Ct. Inspection - Final Inspection Question. Question ID#: 2855.0 Question 25: Which of the following sections of the 2011 NEC covers "Gaps at Edge of Box" for the final inspection?
A: 312.22. B: 314.21. C: 314.15. D: 314.23. Question 26: Kenmore Ct. Inspection - Final Inspection Question. Question ID#: 2856.0 Question 26: Which of the following sections of the 2011 NEC covers "Closet Luminaire Clearance" for the final installation?
A: 410.16. B: 410.14. C: 410.48. D: 410.160. Page 6 2013 JADE Learning, Inc. Residential Electrical Inspections - FL Author: David Burtt Question 27: Kenmore Ct. Inspection - Final Inspection Question. Question ID#: 2857.0 Question 27: Which of the following sections of the 2011 NEC covers "Service Panel Labeled Properly" for the final inspection?
A: 404.8. B: 405.6. C: 406.5. D: 408.4. Question 28: Kenmore Ct. Inspection - Final Inspection Question. Question ID#: 2858.0 Question 28: Which of the following sections of the 2011 NEC covers "Intersystem Bonding Means" for the final inspection?
A: 250.50. B: 250.53. C: 250.94. D: 250.120. Question 29: Kenmore Ct. Inspection - Final Inspection Question. Question ID#: 2859.0 Question 29: Which of the following sections of the 2011 NEC covers "Outside HVAC Disconnecting Means" for the final inspection?
A: 210.63. B: 440.14. C: 440.22. D: 440.64. Question 30: Kenmore Ct. Inspection - Final Inspection Question. Question ID#: 2860.0 Question 30: Which of the following sections of the 2011 NEC covers "Receptacle Outlet if Applicable" (Heating, Air-Conditioning, Refrigeration Equipment) for the final inspection?
A: 210.90. B: 210.70. C: 210.63. D: 210.11(B). Dell Dr. Inspection - Final Inspection Activity Question 31: Dell Dr. Inspection - Final Inspection Question. Question ID#: 2862.0 Page 7 2013 JADE Learning, Inc. Residential Electrical Inspections - FL Author: David Burtt Question 31: Which of the following is true about your inspection on Dell Dr.? This was a final inspection.
A: Approved. B: Disapproved for multiple violations. C: Disapproved for one violation. D: Not enough information to approve or disapprove. Question 32: Dell Dr. Inspection - Final Inspection Question. Question ID#: 2863.0 Question 32: Which of the following sections of the 2011 NEC covers "Proper Location of Receptacles Outlet(s) (Front)" for the final inspection?
A: 210.63. B: 210.52(E). C: 210.70. D: 230.90(A). Question 33: Dell Dr. Inspection - Final Inspection Question. Question ID#: 2864.0 Question 33: Which of the following sections of the 2011 NEC covers "Receptacles GFCI Protected" for the final inspection?
A: 210.70. B: 210.60. C: 210.12(A). D: 210.8(A). Question 34: Dell Dr. Inspection - Final Inspection Question. Question ID#: 2865.0 Question 34: Which of the following sections of the 2011 NEC covers "Proper Location & Clearance" for the final inspection?
A: 110.24. B: 110.26(A). C: 110.26(C). D: 110.26(F). Question 35: Dell Dr. Inspection - Final Inspection Question. Question ID#: 2866.0 Question 35: Which of the following sections of the 2011 NEC covers panelboard "Overcurrent Protection" for the final inspection?
A: 408.36. B: 408.16. C: 408.6. D: 408.4. Question 36: Dell Dr. Inspection - Final Inspection Question. Question ID#: 2867.0 Page 8 2013 JADE Learning, Inc. Residential Electrical Inspections - FL Author: David Burtt Question 36: Which of the following sections of the 2011 NEC covers "Receptacles Grounded Properly" for the final inspection?
A: 406.8. B: 406.5. C: 406.4(A). D: 406.2(A). Question 37: Dell Dr. Inspection - Final Inspection Question. Question ID#: 2868.0 Question 37: Which of the following sections of the 2011 NEC covers "Branch Circuits AFCI Protected" for the final inspection?
A: 210.8. B: 210.12. C: 210.19. D: 210.23. Question 38: Dell Dr. Inspection - Final Inspection Question. Question ID#: 2869.0 Question 38: Which of the following sections of the 2011 NEC covers "Proper Location of Receptacle Outlet(s)" (Appliances) for the final inspection?
A: 210.21. B: 210.50(C). C: 210.60(A). D: 210.52(C). Question 39: Dell Dr. Inspection - Final Inspection Question. Question ID#: 2870.0 Question 39: Which of the following sections of the 2011 NEC covers "Grounding of Equipment" for the final inspection?
A: 250.53. B: 250.94. C: 250.110. D: 250.120. Question 40: Dell Dr. Inspection - Final Inspection Question. Question ID#: 2871.0 Question 40: Which of the following sections of the 2011 NEC covers "Metal Boxes & Covers Grounded" for the final inspection?
A: 314.23. B: 314.21. C: 314.20. D: 314.4. Page 9 2013 JADE Learning, Inc. Residential Electrical Inspections - FL Author: David Burtt Cheswick Dr. Inspection - Final Inspection Activity Question 41: Cheswick Dr. Inspection - Final Inspection Question. Question ID#: 2873.0 Question 41: Which of the following is true about your inspection on Cheswick Dr.? This was a final inspection.
A: Approved. B: Disapproved for multiple violations. C: Disapproved for one violation. D: Not enough information to approve or disapprove. Question 42: Cheswick Dr. Inspection - Final Inspection Question. Question ID#: 2874.0 Question 42: Which of the following sections of the 2011 NEC covers "Outside HACR Service Receptacle" for the final inspection?
A: 210.52. B: 210.63. C: 406.9. D: 230.70(A)(1). Question 43: Cheswick Dr. Inspection - Final Inspection Question. Question ID#: 2875.0 Question 43: Which of the following sections of the 2011 NEC covers "Grounding Electrode System Installation" for the final inspection?
A: 210.52. B: 250.110. C: 250.53. D: 250.50. Question 44: Cheswick Dr. Inspection - Final Inspection Question. Question ID#: 2876.0 Question 44: Which of the following sections of the 2011 NEC covers "Receptacle Mounting" for the final inspection?
A: 406.9. B: 406.6. C: 406.5. D: 404.5. Question 45: Cheswick Dr. Inspection - Final Inspection Question. Question ID#: 2877.0 Question 45: Which of the following sections of the 2011 NEC covers "Grounding of Equipment" for the final inspection?
A: 250.110. Page 10 2013 JADE Learning, Inc. Residential Electrical Inspections - FL Author: David Burtt B: 250.50. C: 250.1. D: 250.120. Question 46: Cheswick Dr. Inspection - Final Inspection Question. Question ID#: 2878.0 Question 46: Which of the following sections of the 2011 NEC covers "Service Conductors Proper Ampacity" for the final inspection?
A: 210.8(A). B: 230.70(A). C: 230.90(A). D: 210.52(A). Question 47: Cheswick Dr. Inspection - Final Inspection Question. Question ID#: 2879.0 Question 47: Which of the following sections of the 2011 NEC covers "Circuits Labeled Properly" for the final inspection?
A: 404.4. B: 406.5. C: 408.4. D: 422.31. Question 48: Cheswick Dr. Inspection - Final Inspection Question. Question ID#: 2880.0 Question 48: Which of the following sections of the 2011 NEC covers "Receptacles GFCI Protected if Required" for the final inspection?
A: 210.5. B: 210.8(A). C: 200.6(A). D: 210.12. Question 49: Cheswick Dr. Inspection - Final Inspection Question. Question ID#: 2881.0 Question 49: Which of the following sections of the 2011 NEC covers "Correct Depth for Outlet Box" for the final inspection?
A: 314.20. B: 314.4. C: 314.21. D: 314.27(C). Question 50: Cheswick Dr. Inspection - Final Inspection Question. Question ID#: 2882.0 Question 50: Which of the following codes covers "Smoke Alarm Proper Location" for the final inspection?
A: NFPA 70. Page 11 2013 JADE Learning, Inc. Residential Electrical Inspections - FL Author: David Burtt B: NFPA 70E. C: NFPA 72. D: NFPA 79. Wrap Up Your Day Activity Question 51: Wrap Up Your Day Question. Question ID#: 2884.0 Question 51: Which of the following sections of the 2011 NEC covers "Hydromassage Tub Access/Receptacle Box Location" for the final inspection?