Installation Accessories
Now includes Waveguide Accessories
Cost-Effective, Value-Added Products
for Superior Performance
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page A
A
B
E
A
E
F
G
C
Cable Installation Accessories
Cable Hoisting and Attachment:
Hoisting Grips, Support/Hoisting Grips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SnapStak Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Click-On Hangers, Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
KwikClamp Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Standard Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Hanger Attachment Adapters and Mounting Hardware . . . . . . . . . . . . . . . . . . . . 9
Cable Ties, Nylon or Velcro

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Hanger Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Weatherproofing:
3M Cold Shrink Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Weatherproofing Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Standard Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cable Entry:
Arrestor Port II Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Standard Cable Entry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Elliptical Waveguide Cable Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Installation Aids:
EASIAX

Prep Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Tool Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Installation Aids Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Lightning Protection
Grounding Kits:
Compact SureGround. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
SureGround. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Standard Grounding Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Grounding Bars:
Universal Ground Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
High Capacity Grounding Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Universal Arrestor Ground Bar Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Arrestor Plus

Surge Arrestors:
T-Series Arrestors, Integrated Arrestors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Gas Tube Surge Arrestors, Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Broadband Surge Arrestors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Services
Planning Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Customer Support Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Internet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
OnePack
SM
Site Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Andrew Institute

Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Appendixes
Appendix 1 Quarterwave Stub Surge Arrestors - Considerations and Selection . . 29
Appendix 2 Gas Discharge Tube Protectors - Considerations and Selection. . . . . 31
Appendix 3 DC Passing Wide Band Arrestors . . . . . . . . . . . . . . . . . . . . . . . . 34
Appendix 4 Lightning Strike Statistics and Definitions . . . . . . . . . . . . . . . . . . . . 35
Appendix 5 Documents Available for Additional Information. . . . . . . . . . . . . . . 36
Appendix 6 Cable Hanger Spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Appendix 7 Part Number Cross Reference MTS to Andrew . . . . . . . . . . . . . . . 45
Table of Contents
A Cable Hoisting and Attachment
B Weatherproofing
C Cable Entry
D Installation Aids
E Grounding Kits
F Grounding Bars
G Arrestor Plus

Surge Arrestors
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page B
AASP the first and only PCS/Cellular Systems Design Software
Andrew is your value-added source for cable installation
accessories and lightning protection. Over sixty years of
industry leadership around the globe allows us to provide
you with a comprehensive selection of cable installation
accessories and lightning protection products. When you
buy Andrew, you buy confidence.
With Andrew in your system build-out, you build in:
Faster installation
Increased versatility
Added safety and reliability
Greater cost effectiveness
Comprehensive customer service
Andrew product performance is the industry standard.
When you need superior performance from your system,
put Andrew cable installation accessories and lightning
protection to work for you.
Andrew quality protects your investment. Reliable Andrew
cable installation accessories and lightning protection help
keep your system operational, lowering repair and
replacement costs.
Andrew service means superior delivery performance.
Our system of global manufacturing facilities and product
warehouses ensures your cable installation accessories
and lightning protection products are where you want them,
when you want them. Our customer service can respond
to your requests on the telephone, or over the Internet.
When planning your next system, specify Andrew. We can
supply your system needs with greater cost effectiveness,
faster installation, superior performance, simplified ordering,
increased versatility, and added safety and reliability.
Andrewfor the best value in cable installation accessories
and lightning protection.
AASP is available on the Andrew Powertools
TM
CD-Rom or as a download from www.andrew.com
Do It Right the First Time with Andrew Accessories
Design your PCS or cellular system in less time, with
greater accuracy, and lower costs with advanced
Andrew Antenna Systems Planner software (AASP).
Powerful AASP software graphically guides you
through the entire design process, from the choice
of frequency to the available shipping options.
The programs dynamic, rule-based logic generates
custom solutions by using standard Andrew products while
automatically checking component compatibility. Upon completion,
AASP provides you with a customized bill of materials of the Andrew
parts necessary for the system.
O
nly fro
m
A
nd
rew
!
1
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 1
How to Choose Your Accessories
The Andrew Installation Accessories
Selection Guide
Once youve selected the cable and connectors for your system, the
cable mounting and protection system must be planned. Andrew offers
a comprehensive line of installation accessories and lightning protection
systems to help you realize your communications systems full potential.
The Andrew Installation Accessories Helpful Assistant
gives you insights and tips on accessories and lightning
protection. These tips can help you select the best
equipment to meet your specific needs.
Hoisting Grips
Select a hoisting grip to safely raise the cable
and hold it during hanger attachment. In some
cases, a hoisting grip must also be used with
a calibrated clamp, available from Andrew,
to provide permanent support for the cable.
Hangers
The type or shape of the structure, the space
available for cable attachment, the type of
environment the system will be exposed to,
and the ease of installation or maintenance are
key considerations. Many hanger options are
available, and many variables have tradeoffs that
affect total hanger system cost. The table on page
11 will help you select the best hangers for your
system and budget.
Weatherproofing
Weatherproofing keeps connector interfaces
tight and adds an additional layer of protection
against the environment. Andrew offers three types
of weatherproofing. A standard weather-proofing
kit provides universal coverage and uses butyl and
vinyl tapes to wrap connector surfaces. Our 3M
Cold Shrink Weatherproofing Kit uses a self-
shrinking technology to reduce installation time.
New weatherproofing enclosures seal and protect
connectors for the environment in seconds.
Grounding Kits
A grounding kit diverts transient currents from
lightning off the transmission line to an earth
grounding system to prevent damage to cable
and radio equipment. A typical installation uses
three grounding kits: near the top of the main
feeder cable, at the bottom of the main feeder
prior to the horizontal run, and just prior to the
cable entering the building. Andrew offers three
kit types to meet the requirements of your system
and budget.
Surge Arrestors
Andrew Arrestor Plus

Surge Arrestors provide the


last stage of an effective lightning protection
system. Install them to divert lightning transients off
the inner conductor of your coaxial cable before
they reach your radio equipment. Select from a
variety of surge arrestors to meet your exact
requirements.
Cable Entry
The final step in a base station installation is to
bring the cable into the building or radio cabinet.
Two basic types of cable entry systems are
available: a standard building entry, and an
integrated system that combines cable entry and
lightning surge suppression into one efficient
system.
Elements of a Cable Mounting and Protection System
Need a Hand?
Look for the Andrew
Installation Accessories
Helpful Assistant.
2
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 2
NEW! SnapStak Hangers
No more worries about fumbling with hardware
or losing small parts because there arent any!
New antenna systems can now be added to crowded multiple-tenant
towerswith minimal space! SnapStak snap-in hangers can be stacked
up to three deep when using 1/2" and 7/8" coaxial cable, or two
deep when using 1-1/4" and 1-5/8" coaxial cable. Each hanger
accommodates one run of HELIAX

cable.
The distinctive, self-contained design of the SnapStak stackable snap-in
hanger eliminates the need for mounting hardware and installation tools.
This simplifies coaxial cable installations, lowering both time and cost.
Retention tabs on the spring fork make
SnapStak hangers highly resistant to
pop-out, so installations are robust and
secure. Yet, specially designed to
dampen vibrations, SnapStak hangers
do not have a rigid hold on the tower,
so motion caused by wind is simply
absorbed. This reduces movement
down the coaxial cable, greatly
reducing stress on the connections at
the jumper cable, antenna, or device.
SnapStak hangers can be mounted directly to the
tower support system, or used in conjunction with a variety of mounting
accessories for rooftops, buildings and water towers. The SnapStak
hanger installs in 3/4" holes in support structures 1/8" (0.120" to
0.150") thick. The stainless steel construction of the SnapStak snap-in
hanger provides exceptional integrity, even in highly corrosive
environments and extreme weather conditions. Compact installations save
tower space. And maintenance is easy, since SnapStak stackable snap-in
hangers are self sufficient no hardware required for installation!
Mounts to pre-punched 3/4" (19 mm) holes. Kit of 10.
Use the support/hoisting grip whenever
possible. Rely on the standard, lace up hoisting
grip only when connectors are pre-attached or
you have to place a grip in the middle of a
cable run over 200 ft.
Cable Hoisting and Attachment
F1SGRIP F1SGRIP-IK 1/4" FSJ1
L1SGRIP L1SGRIP-1IK 1/4" LDF1
E2SGRIP E2SGRIP-2IK 3/8" EFX2
L2SGRIP L2SGRIP-2IK 3/8" LDF2
F2SGRIP F2SGRIP-2IK 3/8" FSJ2
C2SGRIP C2SGRIP-2IK 3/8" CNT-400
L4SGRIP L4SGRIP-4IK 1/2" LDF4
F4SGRIP F4SGRIP-4IK 1/2" FSJ4
L45SGRIP L45SGRIP-45IK 5/8" LDF4.5
L5SGRIP L5SGRIP-5IK 7/8" LDF5, VXL5
L6SGRIP L6SGRIP-6IK 1-1/4" LDF6, VXL6
L7SGRIP L7SGRIP-7IK 1-5/8" LDF7, VXL7
L12SGRIP L12SGRIP-12IK 2-1/4" LDF12
Standard Hoisting Grip
For Transmission Line Installation
Use at 200 ft (60 m) intervals to raise cable on
tower. Use with additional support clamp to
achieve optimum cable grip.
cable installation accessories
ORDERING INFORMATION
Part Number Description
SG-IT Support Clamp Installation Tool
ORDERING INFORMATION
Part Number Part Number
Hoisting Grip Support Clamp Cable Size
43094 L4SGRIP-4IK 1/2"
29958 L45SGRIP-45IK 5/8"
19256B L5SGRIP-5IK 7/8"
29961 L6SGRIP-6IK 1-1/4"
24312A L7SGRIP-7IK 1-5/8"
31535 L12SGRIP-12IK 2-1/4"
26985A NA 3"
34759 NA 4"
31031-1 NA 5"
ORDERING INFORMATION
Part Number Description - Kits of 10
SSH-12 SnapStak hanger kit for 1/2" corrugated cable
SSH-78 SnapStak hanger kit for 7/8" corrugated cable
SSH-114 SnapStak hanger kit for 1-1/4" corrugated cable
SSH-158 SnapStak hanger kit for 1-5/8" corrugated cable
US patents: 6,345,543 6,899,305 and 6,161,804 other patents pending
Support/Hoisting Grip
Safer, Faster Cable Hoisting
Lift and support cable in your monopole or on your tower
faster and more safely and without the threat of slippage.
Our one-piece grip and locking clamp speed and simplify
installation by eliminating time consuming lacing.
Use at 200 ft (60 m) intervals to raise cable and
provide permanent cable support. Basic kit includes
one grip and one support clamp. Support clamps are
also available in kits of10. Installation tool is required.
ORDERING INFORMATION
Part Number Part Number HELIAX

Cable
Support Grip Support Clamp Size Type
3
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 3
SnapStak Hanger Tool
Specially designed pliers make installation and
removal of SnapStak snap-in hangers extremely
easy. The spring loaded pliers are designed
with a hook that holds and spreads the hanger
open to slip easily over the cable. Serrated
pads then squeeze the hanger together for
effortless insertion into the mounting structure.
Insulated handle and a lanyard hole make it
easy to hang on to.
Snap-In Tower Standoffs
For mounting snap-in hangers to round
support members. Adapter is designed
with 3/4" pre-punched hole. Adapter
provides 2-1/2" (60 mm) standoff. All
parts are stainless steel or galvanized.
Kit of 10.
NEW! Universal Snap-In Adapter
The Universal Snap-In Adapter is a versatile device for securing coaxial
cable hangers to structures such as communications towers, rooftops,
buildings and water towers.
The Universal Snap-In Angle Adapter secures coaxial cable to any
round or angle tower members where pre-punched holes are not easily
accessible. The adapter has a pre-punched 3/4" hole that allows the
installer to mount cable hangers such as Andrew SnapStak snap-in
hangers to wireless communications towers or other structures. Made
of stainless steel for long life.
Cable Hoisting and Attachment
cable installation accessories
ORDERING INFORMATION
Part Number Member Diameter, in (mm)
STS-12 1 2 (25 50)
STS-23 2 3 (50 75)
STS-34 3 4 (75 100)
STS-45 4 5 (100 125)
Snap-In Hangers
Attachment with No Hardware!
Andrew Snap-In Hangers provide quick
and easy attachment in all types of
weather. The hangers snap directly
into holes in the tower support members.
Installation time and costs are substantially
reduced. These hangers feature cable gripping
tabs to prevent cable slippage, and are constructed
of heavy gauge stainless steel for high strength and
excellent corrosion resistance. Waveguide versions
include a heavy UV resistant rubber insert to secure
the elliptical cable.
ORDERING INFORMATION
Part Number Description
206706A-6 For 5/8" cables
206706A-5 For 2-1/4" cables
Cable
ladder
rung
Round
member
adapter
Angle
Universal Adapter Applications
ORDERING INFORMATION
Part Number Description
UA-3 Universal Snap-in Adapter, kit of 10
ORDERING INFORMATION
Part Number Description
UAAI Universal Angle Adapter Insert, kit of 10
Universal Angle Adapter Insert
Insert transitions the Universal Adapters 3/4" to
a 3/8" hole diameter, which allows the use of
standard hangers.
Shown with Snap-In Adapter,
each purchased separately
ORDERING INFORMATION
Part Number Description
SHT-4 SnapStak Hanger Tool, quantity 1
Waveguide Type Part Number
EW52 EWSH-52
EW63 EWSH-63
EW64 EWSH-64
EW77 EWSH-77
EW90 EWSH-90
EW127A EWSH-127A
EW132 EWSH-132
EW180 EWSH-180
EW220 EWSH-220
EW249 EWSH-240
4
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 4
NEW! Anchor Rail Adapter*
Anchor Rail Adapters make cable installation
fast, secure, and neat.
These one-piece, one-size, self-contained
Anchor Rail Adapters require no tools and
snap into common strut or anchor rail
systems, such as UniStrut

Metal
Framing. The 3/4" hole accepts
common snap-in hangers. Adapters
can be used for horizontal or vertical
cable to produce neatly aligned
installations on large poles, smokestacks,
rooftops, walls, or any support structure.
*Patent Pending UniStrut is a registered trademark of the UniStrut Corporation
Snap-In Adapter Bracket
This bracket is used in conjunction
with WRAPLOCK

and is used on
large, round members, water towers,
or outside of a monopole. The
brackets slide on the WRAPLOCK
and hold up to six runs of coaxial cable. You can use multiple brackets for
the number of runs required for your system. The galvanized steel bracket
supports both standard hangers and snap-in hangers. Accommodates six
runs of snap-in hangers and four runs of click-on hangers.
Universal Snap-In Bracket
These galvanized steel brackets are designed to
work on both angle and round members. They are
pre-punched with 3/4" holes to hold snap-in hangers
or standard hangers.
PVC Roof Sleeper
Support rooftop coaxial cable runs using the snap-in PVC
Roof Sleepers. PVC Roof Sleepers are pre-punched
with 3/4" holes to accommodate snap-in
hangers. Sleepers are made of a gray
4" (102 mm) x 4" (102 mm), UV-resistant
PVC material.
Snap-In Adapter Block
This Snap-In Adapter Block is designed to
accommodate a snap-in hanger on each side
of the block. You can attach this to the tower with
our standard angle adapters or tower standoffs.
Mechanically galvanized hardware.
ORDERING INFORMATION
Part Number Description
ARA-18 Anchor Rail Adapter for 0.71" (18 mm) rails
(European standard), kit of 10
ARA-22 Anchor Rail Adapter for 0.86" (22 mm) rails
(North American standard), kit of 10
ORDERING INFORMATION
Part Number Description
RM-USBG Snap-In Adapter Bracket
12395-1 Stainless Steel WRAPLOCK
ORDERING INFORMATION
Part Number Description
SHA3 Snap-in Adapter Block, kit of 10
ORDERING INFORMATION
Part Number Description
SS-TB2550 Universal Snap-In Bracket, for 1-1/2" to 5- 9/16"
round member 2-1/2" to 5" angle member.
Accommodates six snap-in or standard hangers.
SS-TB6080 Universal Snap-In Bracket, for 6" to 10-3/4"
round member 6" to 8" angle member
accommodates six snap-in or standard hangers.
ORDERING INFORMATION
Part Number Description
MT-F1598 4 run, 22" (559 mm) length
MT-F1599 8 run, 32" (810 mm) length
MT-F1600 12 run, 43" (1102 mm) length
Cluster Support Bracket
The Cluster Support Bracket is a versatile means
to support multiple runs of coaxial cable in
virtually any application. The oval design allows
coaxial cable to be run inside and outside of the
bracket, which maximizes its capacity. Each
bracket features 3/4" holes to accommodate
snap-in hangers and 3/8" holes for butterfly
hangers using standard 3/8" hardware. The
Cluster Support Bracket supports seven runs of
coaxial cable. Sold in units of one, U-bolt hardware sold separately.
ORDERING INFORMATION
Part Number Description
CS-B Cluster Support Bracket with U-bolt
for 2-3/8" round member attachment
Cable Hoisting and Attachment
5
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 5
Cable Hoisting and Attachment
Click-On Hangers
Click-On Hangers
Install Cable with One Easy Click
Specifically designed to support HELIAX

coaxial cable, stackable Click-On


Hangers install in just minutes and provide
a perfect fit that gives your PCS/PCN, cellular,
microwave, rural telephony, GSM, or other telecommunications
system a professional appearance, especially in confined spaces.
Available in either single or double versions, Click-On Hangers are
manufactured of tough UV-resistant material and set the standard for
durability, simplicity of installation, and cost effectiveness. Click-On
Hangers are sold in kits of 10.
(United States Patent #5794897)
Flat Member Attachment Angle Adapter Attachment
Round Member Attachment Ceiling Adapter Attachment
ORDERING INFORMATION
Double Single*
Part Number Part Number Hanger Description
L4CLICK L4SCLICK 1/2" Hanger for LDF4, kit of 10
L45CLICK NA 5/8" Hanger for LDF4.5, kit of 10
L5CLICKB L5SCLICKB 7/8" Hanger for LDF5, VXL5, kit of 10
L6CLICK L6SCLICK 1-1/4" Hanger for LDF6, VXL6, kit of 10
L7CLICK L7SCLICK 1-5/8" Hanger for LDF7, VXL7, kit of 10
*Contact Andrew for information on hangers complete
with angle adapter and hardware.
SUPPORT HARDWARE ORDERING INFORMATION
Part Number Attachment Hardware
243684 Compact Angle Adapter, see page 10 for details
244350 Ceiling Adapter, kit of 10
Round Member Adapter (various sizes) see page 10
Click-On Hanger Hardware Kits
Click-On Hanger attachment hardware is
available in 3/8" or M10 sizes.
Constructed of stainless steel for
durability. Select hardware length
according to planned hanger stack
height.
Note: Click-On Hangers accommodate two runs of cable and can be
stacked up to three deep to handle up to six runs.
ATTACHMENT HARDWARE DIMENSIONS
Rod Length Rod Length
Part Number (inches) (millimeters)
243095-11 3.97 101
243095-7 5.5 141
243095-3 7.1 181
243095-12 5 126
243095-8 7.3 186
243095-4 9.9 251
243095-9 3.75 95
243095-5 5.4 137
243095-1 7 177
243095-10 4.75 121
243095-6 7.25 184
243095-2 9.75 248
cable installation accessories
ORDERING INFORMATION
Imperial Metric Stack Height Cable Size
Part Number Part Number (# of hangers)
243095-9 243095-11 1 1/2" or 7/8"
243095-5 243095-7 2 1/2" or 7/8"
243095-1 243095-3 3 1/2" or 7/8"
243095-10 243095-12 1 1-1/4" or 1-5/8"
243095-6 243095-8 2 1-1/4" or 1-5/8"
243095-2 243095-4 3 1-1/4" or 1-5/8"
Each kit contains 10 threaded rods, 20 nuts, 40 flat washers and 40 lock washers.
Multi-run hangers are the best choice for installing cables
where space is very limited on crowded towers.
6
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 6
Installation shows Click-On Hangers, SureGround Kits
(weatherproofing removed for illustration) and a Universal Grounding Bar
NEW! Miniature Click-On Hangers
Fast, easy installation for small cables
Now installing small cables into hangers is accomplished
in one easy click with new Miniature Click-On
Hangers.
Each compact, Miniature Click-On Hanger
accommodates two runs of cable. Miniature
Click-On Hangers are compact and
stackable, making it easy to install several
runs of cable in confined spaces.
Miniature Click-On Hangers are cost
effective and durable. With flexible
gripping ribs, the hanger provides secure
support on a range of cable sizes, and
indexing on the hanger body helps align
cables during installation.
Specifically designed to accommodate
small corrugated coaxial cables, elliptical
waveguide, and braided cable runs,
Miniature Click-On Hangers provide a
perfect fit for your installation. Hangers are
packed in kits of 10. Attachment hardware made
of anti-corrosion coated metal for long service life
is sold separately in kits of 10. US patent pending
ORDERING INFORMATION
Select hardware by intended hanger stack height.
Hanger
Part Number Description
68MCLICK Click-On Hangers for 6-8 mm cable;
FSJ1A, CNT-240, CNT-300, BR-240, BR-300, kit of 10
912MCLICK Click-On Hangers for 9-12 mm cable;
LDF1, EFX2, FSJ2, LDF2, CNT-400, BR-400, kit of 10
1316MCLICK Click-On Hangers for 13-16 mm cable;
FSJ4, LDF4-50A, CNT-500, CNT-600, BR-600, kit of 10
ORDERING INFORMATION
Select hardware by intended hanger stack height.
Hanger
Part Number Description
252026-10KT Mini Angle Adapters, M8 tap, kit of 10
252027-10KT Single Stack Hardware for
Mini Click-On Hangers, M8 thread, kit of 10
252028-10KT Double Stack Hardware for
Mini Click-On Hangers, M8 thread, kit of 10
252029-10KT Triple Stack Hardware for
Mini Click-On Hangers, M8 thread, kit of 10
Cable Hoisting and Attachment
7
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 7
KwikClamp Hangers
Multiple Run Cable Hangers for European Norms
Ideal for multiple run cable hangers designed exclusively for European-
style towers, cost effective KwikClamp Cable Hangers eliminate the
need for drilling and adapters. These self-clamping cable hangers
attach directly to round or flat tower members, providing sturdy, reliable,
long-term support to systems. Hangers are sold in kits of 10.
Round/Flat KwikClamp
Cable Hoisting and Attachment
Popular in European site designs, these hangers are
shipped only from Andrew facilities in Europe.
Cable Size RG8 LDF4 LDF4.5 LDF5 LDF6 LDF7
Tower Cable
member type runs Part Number Base
Part Number Base R8CLAMP-( ) L4CLAMP-( ) L45CLAMP-( ) L5CLAMP-( ) L6CLAMP-( ) L7CLAMP-( )
3-11 mm 2 UNV-2
8-25 mm round or 1 RDN-1 RDN-1 RDN-1 RDN-1 RDN-1
3-25 mmflat plate 2 RDN-2 RDN-2 RDN-2 RDN-2 RDN-2
3 RDN-3 RDN-3 RDN-3 RDN-3 RDN-3
Cable and Hanger Type
KwikClamp Ordering Instructions
Refer to the table to build a part number. First select your cable size on
the top row and note the base of the hangers part number below it.
Next refer to the first 2 columns on the left to select the tower member
type and number of cable runs. Cross this to the cable size to find the
part number detail. For example, a hanger for three 7/8" LDF5 cables
on a round tower would be: L5CLAMP-RDN-3
All hangers sold in kits of 10
cable installation accessories
8
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 8
9
A
Angle Adapter
Galvanized and Non-marring
For mounting 1/2" to 2-1/4" cable hangers to angle
tower members up to 3/4" (19 mm) thick. Hanger
attachment hardware sold separately (see above).
Kit of 10.
Standard Hangers for Security and Flexibility
Standard Hangers and Hardware
Standard hangers are designed for easy installation. The clamp locking
bolt and nut are pre-assembled and captivated to minimize installation
labor. Proper tension is easy to determine. The hanger is simply tightened
until there is a 5/16" gap between the clamp legs. The pre-drilled hole
for 3/8" or 1/2" mounting hardware and slots for round member
adapter clamps further simplify installation. See pages 10 and 11 for
accessories to adapt these hangers to most tower configurations.
Hardware Kit of 10 Sets
Imperial kits include 3/8" fillister-head bolts, lock
washers, and nuts for attachment of standard hangers
to drilled tower members. The metric kit includes M10
bolts and lock washers for use with metric angle
adapters.
For Waveguide Waveguide Photo
Type Numbers Hanger Kit Reference
EW17, EWP17 31766A-9 C
EW20 31766A-10 C
EW28 31766A-11 C
EW34, EWP34 42396A-15 B
EW37, EWP37, EWP37S 42396A-4 B
EW43, EWP43 42396A-16 B
EW52, EWP52, EWP52S 42396A-8 B
EW63, EWP63, EWP63S 42396A-7 B
EW64, EWP64 42396A-1 B
EW77, EWP77 42396A-11 B
EW85 42396A-5 B
EW90, EWP90, EWP90S 42396A-5 B
EW127A, EWP127A 42396A-9 B
EW132, EWP132 42396A-9 B
EW180, EWP180 43211A B
EW220 43211A B
EW240 43211A B
Please refer to Appendix 6 for specific recommendations.
STANDARD HANGAR ORDERING INFORMATION
Hanger Nominal Photo
Part Number Cable Size Reference
43211A 3/8" A
43211A 1/2" A
42396A-9 5/8" B
42396A-5 7/8" B
42396A-1 1-1/4" B
42396A-2 1-5/8" B
42396A-4 2-1/4" B
31766A-11 3" C
31766A-10 4" C
ORDERING INFORMATION
Part Number Description
31769-5 3/4" (19 mm) long
31769-1 1" (25 mm) long
243684-MH Metric M10 19 mm long
ORDERING INFORMATION
Part Number Description
247763-I Tapped for 3/8" hardware
247763 Tapped for metric hardware
B C
Other Mounting Hardware
Threaded Rod Support Kit for
Standard Hangers. Use to mount
hangers away from supporting
structure, under cable bridge, and
inside equipment room. Includes
3/8" diameter threaded rod,
galvanized ceiling mounting plate,
nuts, and washers. Attach to angle
tower members with 31768A angle adapters. Attach to
round tower members with 30848 series tower standoffs. All components
are stainless steel, except ceiling mounting plate.
ORDERING INFORMATION
Kit of 1 Kit of 5
Part Number Part Number Rod Length in (mm)
31771 31771-4 12 (305)
31771-9 31771-6 24 (610)
31771-10 36 (915)
Cable Hoisting and Attachment
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 9
Cable Hoisting and Attachment
cable installation accessories
Round Member Adapter
Stainless steel clamps to mount 1/2" to 4" cable
hangers to round support members. Two each are
needed for 3" and 4" cable hangers. Kit of 10.
45 Adapter
Use with angle adapter and threaded rod
support kit to place a hanger at a waveguide
bend. Kit of 10.
Nylon Cable Ties For Jumper
Cable Attachment
Cable ties secure cable bundles where space
is limited. They are an excellent choice for
organizing jumper cables within and between
radio cabinets and for bundling jumper cables.
Nylon cable ties provide support for small
diameter cable 1/4" to 1/2". Typical
applications include securing jumper cables in
buildings and along horizontal antenna mounting arms.
Compact Stainless Steel
Angle Adapters
These compact, lightweight, high quality stainless
steel angle adapters provide a cost saving option to
standard adapters for many wireless systems that use
HELIAX

coaxial cable. These compact angle


adapters are suitable for use with single runs of HELIAX cable up to 2-
1/4" in diameter. When used with our stackable Click-On Hangers, they
can accommodate up to six runs of HELIAX LDF6 1-1/4" cable or smaller
cable and up to four runs of HELIAX LDF7 1-5/8" cable. Includes 3/8
or mid-hanger attachment hardware. Kit of 10.
45 Adapter
Use with angle adapter and threaded rod support kit to place a hanger
at a waveguide bend. Galvanized steel. Kit of 10.
ORDERING INFORMATION
Part Number Description
243684 Imperial Angle Adapter, kit of 10
243684-M Metric Angle Adapter, kit of 10
ORDERING INFORMATION
Part Number Member Diameter, in (mm)
31670-1 12 (2550)
31670-2 23 (5075)
31670-3 34 (75100)
31670-4 45 (100125)
31670-5 56 (125150)
31670-6 68 (150200)
ORDERING INFORMATION
1 in (25 mm) 2.5 in (60 mm) Member Diameter
Standoff Standoff in (mm)
30848-5 0.751.5 (2040)
30848-4 1.53.0 (4075)
30848-1 41108A-1 34 (75100)
30848-2 41108A-2 45 (100125)
30848-3 41108A-3 56 (125150)
Clamp Head
ORDERING INFORMATION
Part Number Description
MF39901-10 Clamp Head, kit of 10
ORDERING INFORMATION
Part Number Description
42334 45 Adapter, kit of 10
ORDERING INFORMATION
Part Number Description
40417 Nylon Cable Ties, 5/16" wide 14.5" long, kit of 50
ORDERING INFORMATION
Part Number Description
42334 Galvanized steel
Angle Adapter
Stainless Steel, kit of 10 pieces. For mounting cable
1/2" to 4" cable hangers to angle tower members up
to 7/8" (22mm) thick. Includes hanger attachment
hardware.
ORDERING INFORMATION
Part Number Description
31768A 3/8" Hardware
31768A-M Metric Hardware
Tower Standoff
Adapters with round member clamps and
hardware for 1/2" to 4" hangers. All parts
are stainless steel or galvanized. Kit of 10.
10
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 10
11
Hanger Selection Guide
Hanger Type
Construction
Cable runs
supported
Primary applications
Typical installation
time (minutes)***
Key feature
Benefits
Attachment
capability
(Tower member type)
Additional parts
needed
Tower adapters
(allows hanger
attachment to
various tower types)
SnapStak Hangers
Stainless steel
1 to 3
Towers with
pre-punched
cable ladders,
snap-in accessories
7
Attaches cables in
compact bundles
saving tower space
Fastest hanger
installation
No additional
hardware needed
Attaches cables in
compact three run
bundles
Impervious to
environmental
extremes
Universal hanger
accommodates all
corrugated cables
3/4" drilled cable
ladder
Various adapters
(see page 4)
None
Cluster mount
Universal tower
adapter
Anchor
rail adapter
KwikClamp
Hangers
Stainless steel
and plastic
1 to 3
New or existing
towers
15
Built in tower
adapter
Requires no
additional hardware
for tower
attachments
Fits round, flat
angle, and c
channel tower
members
Quick installation
UV stable
Round member
Angle member
Channel section
Cable ladders
None
None required
Click-On Single,
Double, or
Miniature Hangers
Engineered plastic
single or double
2 to 6
Rooftops,
water towers
and towers
with limited space
20
Stackable up to
three high
Attaches cables in
compact six run
bundles
Versatile and
adaptable to almost
any application
Easy to install
click-on design
UV stable
3/8" (M10) drilled
hardware ladder
Various adapters
(see page 9-10)
Threaded rod
and hardware
Round member
adapter
Angle adapter
Standard Hangers
Stainless steel
1
Tower installations
subject to high wind,
high corrosion,
high ice
20
Stainless steel
tensioning hardware
Impervious to
environmental
extremes
Adaptable to various
tower configurations
3/8" (M10) drilled
cable ladder
Various adapters
(see page 9)
Tower attachment
hardware kit
Round member
adapter
Angle adapter
Support/
Hoisting Grips*
Tin coated bronze
1
Monopole towers
2
Calibrated clamp
provides permanent
cable support
Quick installation
Monopole
application
Accommodates
single run of cable
All towers and
monopoles
None
None required
Cable Ties**
Nylon
1
Jumper cables and
inter-rack cabling
N/A
Universal fastening
Fits most cable sizes
and tower members
Quick installation
Inexpensive
Accommodates
single run of
lightweight cable
Round member
Angle member
Cable ladders
None
None required
Conditions
* Support Grip or Hoisting/Support Grip required with all cable installations
** Should only be used with 1/2" cable and smaller
*** Installation time based on a 100 ft (30 m) run of 7/8" cable with 3 ft (1 m) hanger spacing. Monopole application applied 200 ft intervals, 2 minutes.
Cable Hoisting and Attachment
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 11
Weatherproofing
cable installation accessories
NEW! Weatherproofing Enclosures
Seal and Protect Connectors
from the Environment in Just
Seconds
Weatherproofing for Main Line Feeders
The weatherproofing gel closure system
provides an additional measure of protection,
providing a watertight seal around the cable and
dampening the vibration that can loosen connector interfaces. Each
enclosure accommodates both N and DIN connections and complements
female main-feeder connectors coupled to male jumper connections using
standard or SureFlex
TM
cable assemblies.
ORDERING INFORMATION
Part Number Cable Size to Cable Size
WE-7812 Enclosure for 7/8 to 1/2 connections
WE-11412 Enclosure for 1-1/4 to 1/2 connections
WE-15812 Enclosure for 1-5/8 to 1/2 connections
More Information:See the installation video on
www.andrew.com/products/trans_line/heliax/weatherproofing.aspx
Weathertight Seal Quickly Installs in Three Minutes
Complete your transmission line installation with the premier
weatherproofing product to seal and protect connectors, splices, surge
protectors, and jumper-to-antenna interfaces from the environment. Andrew
3M Cold Shrink Weatherproofing protects your investment and your
systems performance.
No Tools Required
Cold Shrink Weatherproofing simply slips over the connection and
compresses around the interface. No tapes or heat guns are required
for sealing or shrinking. Simply place the Cold Shrink kit over the cable
and connector, make the connection, and unwind the pull-tab applicator.
Once it is collapsed, its continuous compression design forms a
watertight seal around the cable. Developed jointly by Andrew and
3M Corporation, Cold Shrink
Weatherproofing has proven itself in
thousands of high power cable
installations for more than 15 years.
Fits up to 2-1/4" HELIAX

Cable
Kits are available for transitions
from larger to smaller diameter
cable, such as 1-5/8" to 1/2", or
for same diameter cable, such as
1/2" to 1/2". See the table for part
numbers.
3M and Cold Shrink are trademarks of Minnesota Mining
and Manufacturing Company
Part Number Minutes Application Diameters in (mm)* Kit Coverage Cable Size to Cable Size
Connectors, 7-16 DIN or Type N
245173 0.63 0.41 (1610) 3/8" through 1/2" to 3/8" through 1/2"
241475-13 0.80 0.29 (207.4) 1/4" through 5/8" to 1/4" through 1/2"
241474-7 0.80 0.80 (2020) 5/8" to 5/8"
245171 0.84 0.29 (27.4) 7/8" to 1/4" through 1/2"
245172 1.20 0.29 (307.4) 1-5/8" or 1 1/4" to 1/4" through 1/2"
245175 1.40 0.41 (3610) 2-1/4" to 1/4" through 1/2"
Antennas, filters, amplifiers, 7-16 DIN or Type N**
245174 0.84 0.29 (217.4) 1/2" 7/8" jumpers to antenna
* Minimum application diameter is the fully compressed diameter of each tube in the kit.
**Andrew 3M
TM
Cold Shrink
TM
Weatherproofing is completely compatible with Andrew base station antennas.
Request Bulletin 10138B for complete details and also refer to special publication SP50030 for specific application information on the use of
Cold Shrink
TM
for antenna interfaces.
Weatherproofing for Antennas
Complete your transmission line installation
with Andrew Corporations WeatherShield
Connection Protection Enclosure which
seals and protects connectors from the
environment.
The reusable enclosure contains an
innovative trifold seal that provides
complete moisture block for installed
connectors. The ease of installation on
hard-to-reach connections and the long-
term protection provided by this
enclosure makes it the most cost-
effective solution available today. The
WeatherShield Connection Protection
Enclosure takes just seconds to install.
Simply place the housing around the
connector and snap the tabs together.
AWE-A12 enclosure for
1/2 to antenna/device
ORDERING INFORMATION
Part Number Description
AWE-A12 Enclosure for 1/2 antenna connection/device
12
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 12
13
Standard Weatherproofing Kit
for Connectors and Antennas
The application of sealing
materials to antenna cable
connections protects them
from weather conditions.
These include moisture
penetration and loosening
of connections from
vibrations caused by strong
winds. Andrew Corporation
recommends weatherproofing these connections with standard
weatherproofing tapes such as butyl and plastic electrical tapes.
Main feeder cable-to-jumper cable connection
Jumper cable-to-antenna connection
This kit provides an additional moisture seal for cable connections.
It also prevents loosening of connections from vibration or other external
stresses, which would eventually allow moisture penetration. The sealed
connection is suitable for typical exposed and buried cable applications.
ArrestorPort II
Integrated Transmission Line
Entry/Ground System
The ArrestorPort II integrated building
entry/ground system redefines the way you
achieve cable shelter entry and grounding. Traditional installations rely on
a piecemeal approach that steals time and increases costs. ArrestorPort II
unifies the installation of entry ports, Arrestor Plus

surge protectors, and


transmission line grounding into an integrated entry/ground system.
Arrestor Plus surge arrestors cut costs, save valuable interior space, and
protect your revenues and personnel from the damaging effects of
lightning strikes.
ArrestorPort II Integrated Wall Entry/Grounding System Kit consists of
an entry panel and a 1/8" solid copper ground bar assembly with
assembly hardware, weather stripping, and weatherproof sealing caps
for all entry ports. Use with Arrestor Plus surge arrestors (page 26, order
separately) and standard cable boots (page 14, order separately).
Installers should become thoroughly familiar with and use the installation
tips given here.
Installation Tips
When applied, the tape must be above 32F (0C) to ensure
adhesion. Keep tape warm by carrying in coat pockets.
Do not stretch the tape. Apply only enough tension to provide
a smooth wrap.
Smooth each wrapped layer with your hands to ensure
full adhesion.
Do not pull the tape to tear tape always cut it.
(Pulled tape eventually unravels, decreasing protection.)
Add extra final layers of tape in warmer climates where there
will be long exposure to damaging ultra violet (UV) rays. Two
or three extra layers of tape will provide additional UV protection.
When wrapping tape, overlap the tape to half-width.
Ensure vent or drain holes at the bottom of the antenna
or device are not covered with weatherproofing tape.
Cable Entry
Colored Electrical Marking Tape
Colored tape is a convenient way to mark and code cable runs. Six
different colors are availabe in 3/4x 66 rolls. Sold in individual rolls.
ORDERING INFORMATION
Part Number Description
CM-TB Blue, 3/4 x 66 (19.1 mm x 20.1 m)
CM-TBR Brown, 3/4 x 66 (19.1 mm x 20.1 m)
CM-TG Green, 3/4 x 66 (19.1 mm x 20.1 m)
CM-TR Red, 3/4 x 66 (19.1 mm x 20.1 m)
CM-TW White, 3/4 x 66 (19.1 mm x 20.1 m)
CM-TY Yellow, 3/4 x 66 (19.1 mm x 20.1 m)
WEATHERPROOFING CONNECTIONS PER KIT
Connection Type Applications
Per Kit
2-1/4" to 1/2" (57 mm to 13 mm) 2
1-5/8" to 1/2" (41 mm to 13 mm) 2
1-1/4" to 1/2" (32 mm to 13 mm) 2
7/8" to 1/2" (22 mm to 13 mm) 4
1/2" to 1/2" (13 mm to 13 mm) 12
7/8" to antenna, amplifier, device (22 mm to 13 mm) 12
1/2" to antenna, amplifier, device (13 mm to 13 mm) 12
ORDERING INFORMATION
Standard Weatherproofing Tapes
Part Number Description
221213 Complete kit, Black
221213-S Complete kit, Slate gray
42615-4 2-1/2 x 24 butyl rubber roll
9905-41 3/4 x 66 black plastic tape roll
9905-71 2 x 20 black plastic tape roll
ORDERING INFORMATION
Part Number Description
APORT-13-4 Provides mounting positions for 13 bulkhead mount
surge arrestors and includes four 4" holes for
waveguide entry.
Andrew 221213 Weatherproofing Kit contains:
2 rolls of 3/4" x 66' black plastic tape
1 roll of 2" x 20' black plastic tape
6 rolls of 2-1/2" x 24" butyl rubber tape
Weatherproofing
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 13
Cable Entry
cable installation accessories
ORDERING INFORMATION
Cable Boot Cable Number of
Part Number Size Holes in Boots
4" (102 mm) Cable Boots
204679A-17 1/4" Foam 3
204679A-19 3/8" Foam 1
204679A-5 1/2" Foam 1
204679A-7 1/2" Foam 3
204679A-6 1/2" Air 1
204679A-1 1/2" Air 3
204679A-16 1/2" 4
204679A-13 5/8" 1
204679A-14 5/8" 3
204679A-2 7/8" 1
204679A-18 7/8 2
204679A-15 7/8" 3
204679A-3 1-1/4" 1
204679A-4 1-5/8" 1
204679A-8 2-1/4" 1
204679A-9 3" 1
CAP-4 Blank cap 0
CAP-4-10 Blank cap, kit of 10 0
5" (127 mm) Cable Boots
48939A-16 3/8" Foam 3
48939A-6 1/2" Foam 1
48939A-8 1/2" Foam 3
48939A-7 1/2" Air 1
48939A-5 1/2" Air 3
48939A-17 1/2" 4
48939A-14 5/8" 1
48939A-15 5/8" 3
48939A-1 7/8" 1
48939A-2 7/8" 3
48939A-3 1-1/4" 1
48939A-4 1-5/8" 1
48939A-9 2-1/4" 1
48939A-10 3" 1
EP-CAP5 Blank cap 0
ORDERING INFORMATION
Part Number Cable Size
40656A-3 1/2"
40656A-7 5/8"
40656A-1 7/8"
40656A-5 1-1/4"
40656A-2 1-5/8"
40656A-6 2-1/4"
40394-2 3"
40394-1 4"
33938-5 5"
Standard Cable Entry - Wall, Roof, and Integrated Cable Entry Systems and Accessories
Standard Cable Entry Boots
Use with feed-thru plate with the corresponding
size entry hole.
Multiple Entrance Wall/Roof
Feed-Thru Plate
Plate with one or more 4 or 5-inch holes.
Weatherproof sealing caps included. Use with
the corresponding size rubber cable boot
(sold separately).
Single Entrance Wall/Roof
Feed-Thru Assembly
Includes rubber boot, clamp, and galvanized
steel plate. Order from table.
ORDERING INFORMATION
Part Number of Height Width
Number Openings in (mm) in (mm)
4 (102 mm) Entry Opening, Multiple Entrance Plate
204673-1 1 7 (178) 7 (178)
204673-2 1 5 (127) 5 (127)
204673-2A 3 9.5 (241.3) 20 (508)
204673-4 4 9.5 (241.3) 25.5 (648)
204673-6 6 17.5 (444) 23 (584)
204673-8 8 17.5 (444) 25.5 (648)
204673-9 9 23.0 (584) 23.0 (584)
204673-10 10 9.5 (241.3) 31.0 (787)
204673-12 12 25.5 (648) 25.5 (648)
204673-16 16 25.5 (648) 25.5 (648
204673-18 18 25.5 (648) 39.5 (1003)
204673-20 20 28.8 (731) 31.0 (787)
204673-24 24 31.0 (787) 39.5 (1003)
5" (127 mm) Entry Opening, Multiple Entrance Plate
48940-1 1 9.5 (241) 9.5 (241)
48940-2 2 9.5 (241) 17.5 (241)
48940-3 3 9.5 (241) 25.5 (648)
48940-4 4 17.5 (444) 17.5 (444)
48940-6 6 17.5 (444) 25.5 (648)
48940-8 8 17.5 (444) 33.5 (851)
48940-9 9 25.5 (648) 25.5 (648)
ORDERING INFORMATION
Hole Plugs
Part Number Description
PLUG-12 Plug, 1/2", for unused cable boot holes, kit of 5
PLUG- 78 Plug, 7/8", for unused cable boot holes, kit of 5
PLUG-114 Plug, 1-1/4", for unused cable boot holes, kit of 5
PLUG-158 Plug, 1-5/8", for unused cable boot holes, kit of 5
14
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 14
15
A Single Entrance Wall/Roof Feed-Thru Assembly.
Includes rubber boot, clamp, and galvanized steel plate.
Order from table below.
B Single Entrance Wall/Roof Feed-Thru Assembly for EW37EW240.
Includes rubber boot, clamps, and aluminum plate.
C Waveguide Boot for use with 204673 and 48940 series multiple
entrance wall/roof feed-thru plates. Boot diameter of 4 in or 5 in
(102 or 127 mm) is available to match plate. Order individually
from table below.
C Waveguide Boots
Waveguide Boots
For Waveguide 4 in (102 mm) 5 in (127 mm)
Type Numbers Diameter Diameter
EW17, EWP17
EW20
EW28
EW34, EWP34 204679-34 48939-34
EW37, EWP37, EWP37S WGB4-37 WGB5-37
EW43, EWP43 WGB4-43 WGB5-43
EW52, EWP52, EWP52S WGB4-52 WGB5-52
EW63, EWP63, EWP63S WGB4-63 WGB5-63
EW64, EWP64 WGB4-64 WGB5-64
EW77, EWP77 WGB4-77 WGB5-77
EW85 WGB4-85 WGB5-85
EW90, EWP90, EWP90S WGB4-90 WGB5-90
EW127A, EWP127A WGB4-127 WGB5-122
EW132, EWP132 WGB4-132 WGB5-132
EW180, EWP180 WGB4-180 WGB5-180
EW220 WGB4-220 WGB5-220
EW240 WGB4-240 WGB5-240
Single Entrance Wall/
Roof Feed-Thru Assemblies
Single Entrance
For Waveguide Design Wall/Roof Feed-Thru
Type Numbers Figure Assembly
EW17, EWP17 A 35849A-10
EW20 A 35849A-9
EW28 A 35849A-13
EW34, EWP34 A 35849A-17
EW37, EWP37, EWP37S B 245314-37
EW43, EWP43 B 245314-43
EW52, EWP52, EWP52S B 245314-52
EW63, EWP63, EWP63S B 245314-63
EW64, EWP64 B 245314-64
EW77, EWP77 B 245314-77
EW85 B 245314-85
EW90, EWP90, EWP90S B 245314-90
EW127A, EWP127A B 245314-127A
EW132, EWP132 B 245314-132
EW180, EWP180 B 245314-180
EW220 B 245314-220
EW240 B 245314-240
C
B
C
A
A C B
Elliptical Waveguide - Standard Cable Entry - Wall and Roof Feed-Thru and Boots
Cable Entry
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 15
Installation Aids
cable installation accessories
NEW! EASIAX

2 Cable Prep Tools


Improve system performance and cut installation
time with specialized EASIAX 2
Cable Prep Tools. Wireless
installation specialists require
tools that provide precision and
consistency when attaching connectors.
The tools provide a clean cut of the
coaxial cable and eliminate copper
shavings. This lessens the potential for high VSWR and IMD
readings. EASIAX 2 tools also reduce the time spent preparing cable for
connector attachment by 40%, compared to using common tools.
ORDERING INFORMATION
Tool Part Number Cable Type Connector Type
CPT-L1 LDF1-50 Standard connectors
CPT-E2L2N EFX2-50 Type N connectors
CPT-E2L2DIN EFX2-50 7-16 DIN connectors
CPT-E2L2N LDF2-50 Type N connectors
CPT-E2L2DIN LDF2-50 7-16 DIN connectors
CPT-F4 FSJ4-50B FSJ4 version two connectors
CPT-L4ARC1 LDF4-50, HL4RP-50 7-16 DIN or
Type N standard,
RingFlare, OnePiece
or PositiveStop connectors
CPT-L45RC LDF4.5-50 RingFlare connectors
CPT-78U LDF5-50A 7-16 DIN or
AVA5-50 Type N standard,
VXL5-50 RingFlare, OnePiece,
or PositiveStop connectors
CPTL6 LDF6-50 7-16 DIN or
Type N standard,
RingFlare,OnePiece
or PositiveStop connectors
CPT-158U LDF7-50 7-16 DIN or
AVA7-50 Type N standard,
VXL7-50 RingFlare, OnePiece,
or PositiveStop connectors
ORDERING INFORMATION
Tool
Part Number Description
CPTV2-158 Cable Prep Tool for use with AVA, VXL, and LDF 1-5/8" cable
CPTV2-114 Cable Prep Tool for use with VXL and LDF 1-1/4" cable
CPTV2-BK Replacement blade kit for CPTV2 tools
EASIAX Replacement Blades
REPLACEMENT BLADE ORDERING INFORMATION
Tool Replacement Blade
Part Number Kit Part Number
CPT-L1 CPT-BKS1
CPT-F4 CPT-BK
CPT-L4ARC1 CPT-BKS1
CPT-E2L2DIN CPT-BKS1
CPT-E2L2N CPT-BKS1
CPT-L45RC CPT-BKS1
CPTL6 CPT-BK6
CPT-158U CPT-BK7
CPT-78U CPT-BK5
Recommended drill size for tools for 1/4" through 1/2" cables is 3/8"
torque value with 12 volt minimum. Cordless drill 14.4 minimum voltage,
400 650 RPM.
Recommended drill size for tools for 7/8" through 1-5/8" cable is 1/2".
Cordless drill 15.4 minimum voltage, 400650 RPM.
For detailed information on cable preparation, request Special Publication
50262. See Services section (page 27) to order.
EASIAX

Plus Automated Cable Prep Tool


For Reliable Cable Preparation in 10 Seconds
Cable installers and system designers can
dramatically reduce cable preparation time
and expense while improving overall system
performance with the EASIAX Plus Automated
Cable Preparation Tool. Fit the EASIAX Plus
Tool to any standard power drill,
and it removes the cable jacket, outer
conductor, and foam, then cuts back
and chamfers the inner conductor to
the correct dimensions for connector
attachment all in less than 15 seconds.
The EASIAX Plus automated method of cable
preparation means cable connections that are more consistent,
more reliable, and more repeatable.
Better Connections Yield
Superior System Performance
The connector interface is one of the most critical factors affecting
transmission line operation. Even experienced technicians find the job
more difficult when equipped with makeshift devices or an inadequate
array of simple hand tools, and it only takes a single faulty connection to
degrade performance and threaten your operations revenues.
16
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 16
17
EASIAX

Cable Prep Tool


For Fast, Precision Cuts in 15 Seconds
Type: MCPT
Its Accurate Cuts precisely at crest of
copper corrugation at the exact distance
required for easy connector attachment.
Clean cut makes flaring easier than
ever. Precise blade depth makes it
impossible to cut inner conductor.
Its Consistent Every cut by every
technician on every interface of any
cable will be exactly the same. Its
one more way to ensure consistent
electrical performance for your cable
system.
EASIAX

precision cutting tool is the only cutting tool made exclusively for
HELIAX

coaxial cable.
EASIAX Cutting Tool Ordering Information
ORDERING INFORMATION
For HELIAX

Cable Types Cutting Tool Part No. Features Replacement Blades Kit of 5,Part Number
FSJ1, FSJ4, ETS1, RXL1* Series MCPT-1412 Cuts jacketing and outer conductor 209874
FSJ2, FSJ4,ETS2 Series MCPT-3812 Cuts jacketing and outer conductor 209874
LDF4, HL4RP-50, RXL4** Series MCPT-L4 Cuts outer conductor and scores jacketing MCPT-BK4
LDF5, VXL5, AVA5, RXL5 Series MCPT-78 Cuts outer conductor and inner conductor and scores jacketing MCPT-BK5
* Except RXL1-1RNT
** Except RXL4-(1, 2 or 3) RNT
Except FSJ1RN
Except FSJ4RN
Installation Aids
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 17
Installation Aids
cable installation accessories
Crimping Tool
Used to attach crimp-on lugs for standard
and SureGround series. Not required
for kits having factory-attached lugs.
Connector Attachment Torque Wrenches
Preset to Andrew Specifications
Andrew Torque Wrenches attach any type of HELIAX

connectors to HELIAX LDF4.5, LDF5, LDF6, LDF7, and


LDF12 coaxial cables. All are designed with a mechanism
to audibly notify the installer that the proper torque has
been reached and release the pressure.
Aluminum Grounding Kit Tool
Now installers can prepare transmission line cable for
grounding kit installation in one simple, precise step
and without using a knife! The Andrew Aluminum
Grounding Kit Prep Tool takes just seconds to use:
simply snap the tool in place around the cable and
rotate. In one step the tool removes the exact
amount of jacketing necessary to attach the
grounding strap. The Grounding Kit Prep Tool is a
manually operated cutting device that quickly trims
away a section of cable jacket for the purpose of
grounding strap installation. The tool is ideal for use
on cables mounted close to structures and other
cable runs, and will not scrape or damage the
cables outer conductor.
Cable Reconditioning and
Foam Separating Tools
These tools perform two tasks in one operation: (1)
recondition the cut edge of the outer conductor to its
original shape and dimension and (2) separate the
foam from the outer conductor. This operation forms the
cable end for precise entry into a one-piece connector
and proper attachment. All of the tools except FST-158 have an inner
conductor guide pin on both sides of the tool, one for each cable type.
The larger pin is for LDF cable and the smaller pin is for VXL cable.
ORDERING INFORMATION
FOR CABLE RECONDITIONING AND FOAM SEPARATING TOOL
Tool
Part Number Description
FST-78 For AVA5-50 and VXL5-50 cables
FST-78A For LDF5-50A and VXL5-50 cables
FST-114 For LDF6-50A and VXL6-50 cables
FST-158 For LDF7-50A and VXL7-50 cables
FST-158A For AVA7-50 cable
ORDERING INFORMATION
Part Number Cable Type Connector Type
247696 LDF4-50A OnePiece
245154 LDF4-50A RingFlare
244376 LDF4.5-50 RingFlare and Standard
244378 LDF5-50A, OnePiece, RingFlare,
LDF5-50B and Standard
and VXL5-50
244375 LDF6-50 RingFlare and Standard
247698 LDF6-50 LDF6 OnePiece only
244374 LDF7-50A OnePiece, RingFlare
and Standard
244374 VXL7-50 OnePiece, RingFlare
and Standard
244373 LDF12-50 Standard
244379 All Type N coupling nut
244377 All 7-16 DIN coupling nut
247696 LDF4-50 OnePiece
ORDERING INFORMATION
Part Number Cable Type Grounding Kit Type
GKT-F4A FSJ4 Standard
GKT-L4A LDF4 Standard, CSGL, SGL and SGPL series
GKT-78A LDF5, VXL5, AVA5 Standard, CSGL, SGL and SGPL series
GKT-114A LDF6, VXL6 Standard, CSGL, SGL and SGPL series
GKT-158A LDF7, VXL7, AVA5 Standard, CSGL, SGL and SGPL series
ORDERING INFORMATION
Tool Part Number Replacement Blade Kit
GKT-F4A GKT-BKF4
GKT-L4A GKT-BK512
GKT-78A GKT-BK512
GKT-114A GKT-BK67
GKT-158A GKT-BK67
ORDERING INFORMATION
Part Number
207270
18
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 18
Installation Aids
Cable Tool Part Number Description
Easier Connections with
Attachment Tool Kits
The connector interface is one of the most
critical factors affecting transmission line
operation. Even experienced technicians
can have a hard time when equipped
with makeshift devices or an inadequate
array of simple hand tools, and it only
takes a single faulty connection to
degrade performance and threaten your
operations revenues.
Selection
The table is designed to help you select
the right tools for each HELIAX

cable
size. Under each cable size you will find
a list of part numbers for the appropriate
cable prep tools, cable conditioning tools,
spanner and torque wrenches, and
grounding kit prep tools.
Youll have the option of selecting a
manual or automated cable prep tool.
Under the individual tools you will find
the torque wrenches for the connector
interface nuts.
Manual Cable Prep Tool for 3/8" FSJ1-50 cable
Cut-off Tool 7/32"
Cut-off Tool 8/32"
Cut-off Tool 9/32"
Manual Cable Prep Tool for 3/8" FSJ2-50 cable
Cut-off Tool 7/32"
Cut-off Tool 8/32"
Cut-off Tool 9/32"
Automated/Manual Cable Prep Tool for 1/2" coaxial SuperFlexcable
Manual Cable Prep Tool for 1/2" SuperFlex FSJ4-50B cable
Chamfer Tool
Cut-off Tool 7/32"
Cut-off Tool 8/32"
Cut-off Tool 9/32"
Automated/Manual Cable Prep Tool for 1/2" coaxial cable
21 mm Torque Wrench for L4- OnePiece connectors
3/4" Torque Wrench for L4- RingFlare connectors
Manual Cable Prep Tool for 1/2" LDF4-50A cable
Plastic Grounding Kit Stripping Tool for LDF4 cable
Replacement Blade Kit for Grounding Kit Stripping Tool for LDF4 cable
Manual Cable Prep Tool for 7/8" VXL5 or LDF5 cable
Automated Cable Prep Tool for 7/8 cable
1-1/4" Torque Wrench for 7/8" connectors
1-3/8" Open End Wrench for OnePiece 7/8" connectors.
Fits body of PositiveStop connectors
1-1/4" Open End Wrench for 7/8" connectors.
Fits clamping nut of Positive Stop connectors.
Foam and Separating Tools for LDF5-50B and VXL5-50 cable
Foam and Separating Tools LDF5-50A and VXL5-50 cable
Aluminum Grounding Kit Stripping Tool for 7/8" cable
Replacement Blade Kit for Plastic Grounding Kit Stripping Tool for 7/8" cable
Manual Cable Prep Tool for 1-1/4" VXL6 or LDF6 cable
Replacement Blade for CPTV2-114
Automated Cable Prep Tool for 1-1/4" LDF6 cable
1-7/8" Torque Wrench 1-1/4" standard or RingFlare
TM
connectors
1-3/4" Torque Wrench for 1-1/4" OnePiece connectors
Foam and Separating Tool for LDF6-50 and VXL6-50 cable
Aluminum Grounding Kit Stripping Tool for 1-1/4" cable
Replacement Blade Kit for Grounding Kit Stripping Tool for 1-1/4" cable
1-7/8" Open End Wrench
Manual Cable Prep Tool for 1-5/8" VXL7 or LDF7 cable
Replacement Blade for CPTV2-158
Automated Cable Prep Tool for 1-5/8" cable
2-1/4" Torque Wrench for 1-5/8" connectors
2-1/4" Open End Wrench for 1-5/8" connectors
Foam and Separating Tool for LDF7-50 and VXL7-50 cable
Aluminum Grounding Kit Stripping Tool for 1-5/8" cable
Replacement Blade Kit for Grounding Kit Stripping Tool for 1-5/8" cable
*MCPT-1412 . . . . .
224361 . . . . . . . .
224362 . . . . . . . .
244494 . . . . . . . .
MCPT-3812 . . . . .
224361 . . . . . . . .
224362 . . . . . . . .
244494 . . . . . . . .
CPT-F4 . . . . . . . . .
MCPT-1412 . . . . .
241953 . . . . . . . .
224361 . . . . . . . .
224362 . . . . . . . .
244394 . . . . . . . .
CPT-L4ARC1 . . . . .
247696 . . . . . . . .
245154 . . . . . . . .
MCPT-L4 . . . . . . . .
GKT-L4A . . . . . . . .
GKT-BK512 . . . . . .
*MCPT-78 . . . . . . .
CPT-78U . . . . . . . .
244378 . . . . . . . .
245516 . . . . . . . .
244459-5 . . . . . .
FST-78 . . . . . . . . .
FST-78A . . . . . . . .
GKT-78A . . . . . . . .
GKT-BK512 . . . . . .
CPTV2-114 . . . . . .
CPTV2-BK . . . . . . .
CPTL6 . . . . . . . . .
244375 . . . . . . . .
247698 . . . . . . . .
FST-114 . . . . . . . .
GKT-114A . . . . . . .
GKT-BK67 . . . . . . .
244459-6 . . . . . .
CPTV2-158 . . . . . .
CPTV2-BK . . . . . . .
CPT-158U . . . . . . .
244374 . . . . . . . .
244459-7 . . . . . .
FST-158 . . . . . . . .
GKT-158A . . . . . . .
GKT-BK67 . . . . . . .
1/4" cable
3/8" cable
1/2" cable F4
F4 and L4
1/2" cable L4
7/8" cable
1 1/4" cable
1 5/8" cable
General Purpose TB-COMP-KIT . . . . .Complete Tool Box Kit includes all individual tools marked
with and asterisk in the list below.
Individual Tools 244379 . . . . . . . .
244377 . . . . . . . .
*224352 . . . . . . .
*224354 . . . . . . .
*224355 . . . . . . .
*224356 . . . . . . .
*224360 . . . . . . .
*224363 . . . . . . .
*224368 . . . . . . .
*224373 . . . . . . .
*224380 . . . . . . .
*224395 . . . . . . .
*114468 . . . . . . .
*114469 . . . . . . .
Type N coupling nut torque wrench
7-16 DIN type coupling nut torque wrench
Safety knife
Ruler
Grease brush
Point file
Pin alignment tool
Cable flare tool LDF4
Cable flare tool LDF5
Cable flare tool LDF6
Pin depth gauge N-male
Pin depth gauge N-female
Pin depth gauge DIN-male
Pin depth gauge DIN-female
19
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 19
Grounding Kits
lightning protection
NEW! Compact SureGround Grounding Kits
Now wireless communications system installers and designers can protect
their systems from the effects of lightning easier and at lower cost. The
new Compact SureGround Grounding Kit, available only from Andrew,
is a one-piece grounding assembly with the weatherproofing molded right
into the grounding strap.
Compact SureGround Grounding Kit features:
Easy attachment
Self-locking, self-sealing weatherproof boot eliminates
loose hardware and taping
Saves up to an hour of installation time per typical nine run site
Sure protection
Largest surface contact area in the industry
Provides surety of protection against even the
most severe lightning strikes
Waterproof to IEC529, IP68
Compact size
Snap and lock installation ideal for tight cable
bundles or crowded towers
Exclusive universal grounding lug can be fitted
to a one- or two- hole earthing attachment point.
US patent 6,548,762, others patents pending
More Information
See Compact Sureground
Ordering Information on Page 23
See the installation video on
www.andrew.com/products/trans_line/heliax/sureground.aspx
SureGround Standard Compact
SureGround
Easy Installation
Position Compact SureGround Snap and Lock to Seal
The Compact SureGround fits neatly in tight cable bundles
The Compact SureGround Kit with integrated
weatherproofing is the choice for the speediest
installation, best fit in tight locations, and long
term protection.
20
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 20
21
Grounding Kits
General Features
Heavy Duty Ground Lead
Andrew Grounding Kits use heavy duty 16 mm
2
ground leads
to maximize performance. The IEC 1024-1 compliant copper ground
lead reduces dc resistance. The extremely pliable jacket provides
protection and makes it easy to maneuver the lead into position for
attachment to the down conductor.
Solid copper construction for high current handling capability,
compatibility with copper cable outer conductors.
Meets military standards at commercial prices.
Provides certainty of continued operation.
Tested at an independent laboratory.
Grounding Point
Grounding Point 4
(Runs longer than 200 ft.)
Grounding
Point 2
Grounding
Point 3
Point 1
Universal Grounding Lugs
This grounding lug provides you with the option of a one-hole
configuration or two-hole configuration. Just break
away the bottom portion of the lug and this will
give you your one-hole lug. This Universal Lug
will fit common buss bar configurations with
two-hole spacings of 0.750, 0.815 or 1.0".
Designed to crimp on 16 mm
2
grounding
wire. Included on all grounding kits and
available separately.
for two bolt grounding
for one bolt grounding
Versatile Grounding Lug
Transmission Line Grounding
A well designed system uses grounding kits to provide a bond between
the cable and the tower/earth ground system. One grounding kit is
recommended at tower top, tower bottom, at 200 ft (60 m) intervals (where
applicable), and at the entrance to the equipment shelter. Andrew solid
copper grounding kits have passed United States Air Force lightning
simulation tests and meet MIL-STD-188-124A. The non-braided solid copper
construction of all Andrew grounding kits eliminates corrosion caused by
moisture retention and wicking. A heat shrink tube protects the cable
terminal connection.
Crimping Tool for SureGround
and Standard Grounding
The crimping tool is used to attach crimp-on lugs for standard and
SureGround series grounding kits. Not required for kits with factory
attached lugs.
ORDERING INFORMATION
Part Number Description
245529-10 Universal Grounding Lug, kit of 10
207136-3 Grounding Lug hardware kit
ORDERING INFORMATION
Part Number Description
207270 Crimping Tool, kit of 1
Simply snap off pre-scored lug for one hole option
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 21
Grounding Kits
lightning protection
Standard Grounding Kits
Offer Easy Installation for System Protection
Standard Grounding Kits are traditional solutions
for lightning protection and are also well suited
for elliptical waveguide installations. One
grounding kit is recommended at the tower
top, tower bottom, at 200 ft (60 m) intervals,
and at the entrance to the equipment shelter.
Standard Grounding Kits (204989 and
241088 series) require few steps to install and
include easy-to-follow instructions. Proper tensioning
is ensured by an expansion section that provides visual indication
that the strap is secured.
Series 204989 and 241088 kits include a solid copper strap riveted to
the grounding wire, coiling tool for proper tightening, universal grounding
lug, tower attachment hardware, and a two-part tape weatherproofing
system. Field-attachable, crimp-on grounding lugs require a crimping tool
(not included).
Key Feature Over-molded weatherproof Preformed clip-on strap Wraparound grounding strap Multiple cable size
design for easy, fast installation wraparound grounding strap
Benefits Uniform installation compact Requires no tools Fits standard coaxial cable Breakaway design fits
design for bundled installation for installation and elliptical waveguide multiple sizes of coaxial cable
and elliptical waveguide
Installation Time Less than 1 minute About 3 minutes About 6 minutes About 7 minutes
Construction Preformed copper Pre-tensioned copper Copper ground strap Copper ground strap
ground strap ground clip
Over-molded weatherproof Standard weatherproofing Standard weatherproofing Standard weatherproofing
boot, easy lock tabs
Grounding Kit Selection Guide
Compact SureGround SureGround Standard Universal
Universal Connector Grounding Kit
40 mm x 22 mm x 17 mm
SureGround Kits
Fast Installation,
Complete Protection
Protect your equipment from
the effects of lightning with
SureGround Grounding Kits.
Meeting both MIL and IEC
standards, the SureGround
self-securing ground strap
eliminates the need for
attachment tools and provides
protection against lightning strikes up
to 125 kA. Quality non-braided solid
copper construction prevents moisture retention
and wicking, while a heavy duty 16 mm
2
IEC 1024-1 compliant
copper ground lead maximizes performance. Installation is fast, easy,
and error-free. Grounding kits include a solid copper strap riveted to
the grounding wire, tower attachment hardware, and a two-part tape
weatherproofing system.
US patent 5,850,056
Connector Grounding Kit for Mounting Rail
ORDERING INFORMATION
Part Number Description Quantity
244495 Universal Connector Grounding Kit 1
ORDERING INFORMATION
Part Number Description
CGT12 Connector Ground Kit fits all F4 and L4
(except OnePiece) series connectors
CGT58 Connector Ground Kit fits all L4.5 and L5
standard connectors
CGT78 Connector Ground Kit fits all L5, V5, A5, OnePiece,
and Positive Stop series connectors
CGT114 Connector Ground Kit fits all L6 and V6 series connectors
CGT158 Connector Ground Kit fits all L7 and V7 series connectors
CGT214 Connector Ground Kit fits all L12 series connectors
22
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 22
23
Compact SureGround Ordering Information
HELIAX

Cable Type 600 mm 1 meter 1.5 meters


factory attached lug factory attached lug field attached lug
1/2" LDF4 Black CSGL4-06B2 CSGL4-10B2 CSGL4-15B4
1/2" LDF4 Gray CSGL4-06S2 CSGL4-10S2 CSGL4-15S4
7/8" LDF5 Black CSGL5-06B2 CSGL5-10B2 CSGL5-15B4
7/8" LDF5 Gray CSGL5-06S2 CSGL5-10S2 CSGL5-15S4
1-1/4" LDF6 Black CSGL6-06B2 CSGL6-10B2 CSGL6-15B4
1-1/4" LDF6 Gray CSGL6-06S2 CSGL6-10S2 CSGL6-15S4
1-5/8" LDF7 Black CSGL7-06B2 CSGL7-10B2 CSGL7-15B4
1-5/8" LDF7 Gray CSGL7-06S2 CSGL7-10S2 CSGL7-15S4
SureGround Ordering Information
HELIAX

Cable Type 600 mm 1 meter 1.5 meters


factory attached lug factory attached lug field attached lug
1/2" LDF4 Black SGL4-06B2 SGL4-10B2 SGL4-15B4
1/2" LDF4 Gray SGL4-06S2 NA NA
5/8" LDF4.5 SGL45-06B2 SGL45-10B2 SGL45-15B4
7/8" LDF5 Black SGL5-06B2 SGL5-10B2 SGL5-15B4
7/8" LDF5 Gray SGL5-06S2 NA NA
1-1/4" LDF6 Black SGL6-06B2 SGL6-10B2 SGL6-15B4
1-1/4" LDF6 Gray SGL6-06S2 NA NA
1-5/8" LDF7 Black SGL7-06B2 SGL7-10B2 SGL7-15B4
1-5/8" LDF7 Gray SGL7-06S2 NA NA
2-1/4" LDF12 SGL12-06B2 SGL12-10B2 SGL12-15B4
Standard Grounding Kit Ordering Information
HELIAX

Cable Type 24 36 60
factory attached lug factory attached lug field attached lug
1/4" and 3/8", EW240 223158-2 223158-3 223158-4
1/2", EW180, EW220 241088-1 241088-6 241545
5/8" and 7/8", EW85, EW90, EW127A, EW132 241088-2 241088-7 220497
1-1/4", EW64, EW77 241088-3 241088-8 241088-60
1-5/8", EW52, EW63 241088-4 241088-9 220498
EW43 204989-10 241088-64 204989-28
2-1/4" and 3", EW28, EW34, EW37 241088-5 241088-10 223700-724
4", EW17, EW20 204989-6 NA NA
5" 204989-7 NA NA
SureGround Plus Ordering Information
HELIAX

Cable Type 600 mm 1 meter 1.5 meters


factory attached lug factory attached lug field attached lug
5/8" LDF4.5 SGPL45-06B2 SGPL45-10B2 SGPL45-15B4
2-1/4" LDF12 SGPL12-06B2 SGPL12-10B2 SGPL12-15B4
Universal Ground Ordering Information
HELIAX

Cable Type 60
field attached lug
1/2" - 1-5/8" (EW180-EW63) UG12158-15B4
Grounding Kits
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 23
Grounding Bars
lightning protection
2 Ground Buss Bar
Part Number Description
2" x 10" Ground Buss Bar Kits
Bare Copper
UGBKIT-0210 Universal Ground Buss Bar Kit, 1/4" x 2" x 10"
(6.4 mm x 50.8 mm x 254.0 mm)
with Universal Buss Bar Hardware Kit
Tinned Copper
UGBKIT-0210-T Universal Tinned Ground Buss Bar Kit,1/4" x 2" x 10"
(6.4 mm x 50.8 mm x 254.0 mm)
with Universal Buss Bar Hardware Kit
2" x 12" Ground Buss Bar Kits
Bare Copper
UGBKIT-0212 Universal Ground Buss Bar Kit, 1/4" x 2" x 12"
(6.4 mm x 50.8 mm x 304.8 mm)
with Universal Buss Bar Hardware Kit.
Tinned Copper
UGBKIT-0212-T Universal Tinned Ground Buss Bar Kit, 1/4" x 2" x 12"
(6.4 mm x 50.8 mm x 304.8 mm)
with Universal Buss Bar Hardware Kit.
2" x 14" Ground Buss Bar Kits
Bare Copper
UGBKIT-0214 Universal Ground Buss Bar Kit, 1/4" x 2" x 14"
(6.4 mm x 50.8 mm x 355.6 mm)
with Universal Buss Bar Hardware Kit.
Tinned Copper
UGBKIT-0214-T Universal Tinned Ground Buss Bar Kit,
1/4" x 2" x 14"
(6.4 mm x 50.8 mm x 355.6 mm)
with Universal Buss Bar Hardware Kit.
2-1/2 Ground Buss Bar
Part Number Description
2-1/2" x 12-1/2" Ground Buss Bar Kits
Bare Copper
UGBKIT-2 Universal Ground Buss Bar Kit, 1/4" x 2-1/2" x 12-1/2"
(6.4 mm x 63.5 mm x 317.5 mm)
with Universal Buss Bar Hardware Kit.
Tinned Copper
UGBKIT-2T Universal Tinned Ground Buss Bar Kit,
1/4" x 2-1/2" x 12-1/2"
(6.4 mm x 63.5 mm x 317.5 mm)
with Universal Buss Bar Hardware Kit.
2-1/2" x 19-1/2" Ground Buss Bar Kits
Bare Copper
UGBKIT Universal Ground Buss Bar Kit, 1/4" x 2-1/2" x 19-1/2"
(6.4 mm x 63.5 mm x 495.3 mm)
with Universal Buss Bar Hardware Kit.
Tinned Copper
UGBKIT-T Universal Tinned Ground Buss Bar Kit,
1/4" x 2-1/2" x 19-1/2"
(6.4 mm x 63.5 mm x 495.3 mm)
with Universal Buss Bar Hardware Kit.
Andrew offers a complete range of grounding buss bar sizes
and hole pattern configurations to accomodate just about any
application. Each grounding bar is made from 1/4 solid copper
bar stock and is available with optional tin plating. Kits come
complete with insulators, stainless steel brackets, adapters, and
hardware for mounting to a wall or tower.
24
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 24
Universal Arrestor
Ground Bar Assembly
This pre-punched solid copper ground
bar assembly simplifies mounting and
grounding of surge arrestors inside the
building. Instead of relying on
individual wires or field-fabricated
trapeze setups, the Andrew Universal Arrestor Ground Bar Assembly
provides a uniform mounting and grounding point for surge arrestors and
grounding leads. The 1/8" assembly uses three horizontal members that
can be oriented flat or upright and adjusted vertically as needed to
accommodate various surge arrestor types. Also included is a mounting
kit that includes ceiling brackets, insulators, threaded rod, and hardware.
Compatible with standard entry port sizes
Height-adjustable bars
Solid copper construction
Accepts bulkhead or bolt grounded surge arrestors
Accommodates one- and two-hole grounding lugs
Eliminates need for internal buss bar
Type Number and Description
UGBA-DIN-36 - Universal Ground Bar Assembly with three 6-position
ground bars punched for oversized 7-16 DIN mount arrestors
(APTL and APT series) or bolt-grounded arrestors.
UGBA-36 - Universal Ground Bar Assembly with three 6-position ground
bars punched for most 7-16 DIN, Type N, or bolt-grounded arrestors.
(Andrew APG and APM series arrestors)
UGBA-DIN-34 - Universal Ground Bar Assembly with three 4-position
ground bars punched for oversized 7-16 DIN mount arrestors
(APTL and APT series) or bolt-grounded arrestors.
UGBA-34 - Universal Ground Bar Assembly with three 4-position ground
bars punched for most 7-16 DIN, type N or bolt-grounded arrestors.
(Andrew APG and APM series arrestors)
25
4 Ground Buss Bar
Part Number Description
4" x 12" Ground Buss Bar Kits
Bare Copper
UGBKIT-0412 Universal Ground Buss Bar Kit, 1/4" x 4" x 12"
(6.3 mm x 101.6 mm x 304.8 mm)
with Universal Buss Bar Hardware Kit.
Tinned Copper
UGBKIT-0412-T Universal Tinned Ground Buss Bar Kit, 1/4" x 4" x 12"
(6.3 mm x 101.6 mm x 304.8 mm)
with Universal Buss Bar Hardware Kit
4" x 14" Ground Buss Bar Kits
Bare Copper
UGBKIT-0414 Universal Ground Buss Bar Kit, 1/4" x 4" x 14"
(6.3 mm x 101.6 mm x 355.6 mm)
with Universal Buss Bar Hardware Kit.
Tinned Copper
UGBKIT-0414-T Universal Tinned Ground Buss Bar Kit, 1/4" x 4" x 14"
(6.3 mm x 101.6 mm x 355.6 mm)
with Universal Buss Bar Hardware Kit.
4" x 20" Ground Buss Bar Kits
Bare Copper
UGBKIT-0420 Universal Ground Buss Bar Kit, 1/4" x 4" x 20"
(6.3 mm x 101.6 mm x 508.0 mm)
with Universal Buss Bar Hardware Kit.
Tinned Copper
UGBKIT-0420-T Universal Tinned Ground Buss Bar Kit, 1/4" x 4" x 20"
(6.3 mm x 101.6 mm x 508.0 mm)
with Universal Buss Bar Hardware Kit.
4" x 24" Ground Buss Bar Kits
Bare Copper
UGBKIT-0424 Universal Ground Buss Bar Kit, 1/4" x 4" x 24"
(6.3 mm x 101.6 mm x 609.6 mm)
with Universal Buss Bar Hardware Kit.
Tinned Copper
UGBKIT-0424-T Universal Tinned Ground Buss Bar Kit, 1/4" x 4" x 24"
(6.3 mm x 101.6 mm x 609.6 mm)
with Universal Buss Bar Hardware Kit.
Grounding Bars
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 25
26
Arrestor Plus

Lightning Surge Arrestors


T-Series Surge Arrestors
Arrestor Plus

T-Series Surge Arrestors give


engineers more flexibility when configuring
lightning protection systems. This slim-profile
arrestor fits easily inside equipment
enclosures, and offers true multistrike
protection. The Arrestor Plus bulkhead
mount T-Series features universal Type N
and 7-16 DIN interfaces.
Arrestor Plus Replaceable
Gas Tube Surge Arrestors
Offering broadband performance
from 02000 MHz and excellent
electrical characteristics, Arrestor
Plus Replaceable Gas Tube Surge
Arrestors are easy to install and
feature dc pass capability through the
center conductor to the active tower top
electronics. The units removable cap
makes periodic maintenance fast and easy.
T-SERIES SURGE ARRESTORS SELECTION GUIDE
Surge Arrestor Key Benefit
TSeries Universal installation splice into any system
dc Pass dc pass capability bulkhead and standard
grounding splice into any system
Add the final measure of protection to your equipment from lightning
current traveling down the transmission line with Arrestor Plus Surge
Arrestors. All designs are completely weatherproof and feature low return
and insertion loss and low intermodulation. A wide range of surge
arrestor types and configurations are available to support just about any
application.
Arrestor Plus T-Series Dual Band
800-2200 MHz
APT-DFDF-DB
APT-DFDM-DB
ATP-BDFDF-DB
APT-BDFDM-DB
APT-NFNF-DB
APT-NFNM-DB
Arrestor Plus
dc Passing Wideband
800-2200 MHz
APTDC-BDFDF-DB
APTDC-BDFDM-DB
Arrestor Plus Gas Tube
0-2000 MHz 0-2000 MHz
APG-BDFDF-090 APG-BDFDF-350
APG-BDFDM-090 APG-BDFDM-350
APG-BNFNM-090 APG-BNFNM-350
APG-BNFNF-090 APG-BNFNF-350
Arrestor Plus Broadband
2000-2800 MHz
APB-BNFNF-2400
APB-BNFNM-2400
2000-6000 MHz
BB-BNFNFE-2G
Broadband T-Series
Dual Band
dc-Pass
Dual Band
Replaceable
Gas Tube
T-Series Surge Arrestors provide multistrike protection and offer the best RF performance for most applications. Select the integrated
series to eliminate the need for a connector and achieve better RF performance. Use the T-series as a universal replacement for
existing systems. APTDC-series gives you protection like quarterwave devices with dc passing capability. The gas tube series is
ideally suited for applications requiring dc pass capability. Refer to Appendixes 1 and 2 for detailed information on Arrestor Plus

Surge Arrestor technologies and typical performance parameters of each.


ORDERING INFORMATION
Part Number Description
APG-BDFDF-* 02000 MHz Surge Arrestor, bulkhead
7-16 DIN female/7-16 DIN female
APG-BDFDM-* 02000 MHz Surge Arrestor, bulkhead
7-16 DIN female/7-16 DIN male
APG-BNFNM-* 02000 MHz Surge Arrestor, bulkhead
Type N female/Type N male
APG-BNFNF-* 02000 MHz Surge Arrestor, bulkhead
Type N female/Type N female
GASTUBE-090 90-volt Gas Tube Replacement, kit of 10
GASTUBE-350 350-volt Gas Tube Replacement, kit of 10
243951 90-degree Mounting/Grounding Bracket, Type N
243950 90-degree Mounting/Grounding Bracket, 7-16 DIN
244847 DIN (APTL)
* specify gas tube static sparkover voltage:
09090 volt 350350 volt
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 26
27
Internet
Now its easier than ever to do business with the worlds premier provider
of RF subsystem solutions. Our website www.andrew.com, provides the
latest in product information, customer service, and technical support.
With features like Industry Solutions, On-Line Order Status, a powerful
search function, fast and easy navigation, and password-protected
sections tailored for specific customer needs, www.andrew.com is your
comprehensive source for information on Andrew products and services.
Updated Interface
The industrys best planning software
Online Andrew Institute

training registration
Technical information
Tailored Partner Portals
Andrew Catalog 38
Andrew Access webzine
News and Events, and much more!
Now www.andrew.com makes it easier than ever to do business with
the worlds provider of RF subsystem solutions.
Planning Software
AASP the first and only PCS/Cellular Systems Design Software
Design your PCS or cellular system in less time,
with greater accuracy, and lower costs with
advanced Andrew Antenna Systems Planner
software (AASP). Powerful AASP software
graphically guides you through the entire
design process, from the choice of frequency
to the available shipping options. The
programs dynamic, rule-based logic generates
custom solutions by using standard Andrew
products while automatically checking component
compatibility. Upon completion, AASP provides you with a customized
bill of materials of the Andrew parts necessary for the system.
Customer Support Center (CSC)
Service Around the Clock, Around the World
Andrew Corporations CSC provides easy
access to comprehensive technical and
customer support including product
information, catalog guidance, and other
reference information to Andrew customers
worldwide.
Contact the Andrew Customer Support Center for:
Technical support
Order status
Replacement materials
Product information
Coordinating product service, repairs, or replacement
Call toll free from:
North America . . . . . . . . . . . . . . . . . . . .1-800-255-1479
Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-800-349-5444
International:
United Kingdom . . . . . . . . . . . . . . . . . . . . .0800-250055
Australia . . . . . . . . . . . . . . . . . . . . . . . . . .1800-803 219
New Zealand . . . . . . . . . . . . . . . . . . . . . .0800-441-747
Call from other areas: . . . . . . . . . . . . . .+1 708-873-2307
OnePack
SM
Site Kits
The Answer for More Efficient
System Build-outs
Todays global build-out demands new
solutions that speed system deployment
and simplify supply chain
management. To help system
managers better achieve these
goals, Andrew offers kits for
wireless RF communications
systems sites. OnePack Site Kits
provide the critical components in
easy to order, easy to manage packages. System designers and
managers can be confident of shortened project planning and execution
cycles, improved efficiency, and dependable system performance.
AASP is available on the Andrew Powertools
TM
CD-Rom
or as a download from www.andrew.com
services
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 27
Installation Techniques to Ensure Quality!
Andrew products and people are at the forefront of connecting the
wireless world. As the industry evolves, the Andrew Institute

is
committed to providing you with quality, effective training. Our trainers
deliver knowledge that can develop your skills and self-assurance, as
well as benefit your system performance and reliability. Dedicated
Andrew Institute trainers will share their proven installation techniques
and expertise with you in one or two-day sessions.
Build an Agenda Customize Your Training:
Connector Attachment (1 hour per connector)
Cable concepts
Connector attachment
Accessories
Fundamentals of VSWR (3 hours)
Typical site configuration
Plot/sweep interpretation
Troubleshooting
Base Station Antennas (4 hours)
Antenna concepts
Mounting techniques
Weatherproofing
Inspection and maintenance
Terrestrial Microwave Systems (2 days)
RF theory/TMW fundamentals
Antenna installation
Path alignment
Pressurization fundamentals
Benefits of Andrew Institute
Technical Training
You will learn:
how to obtain the highest
possible performance with
every Andrew product installed.
system fundamentals and how
components work together.
proper installation of cable, connectors,
and accessories through hands-on practice.
TMW systems fundamentals and essential elements of path alignment.
pressurization systems theory of operation and installation techniques.
proper path alignment.
fundamentals of VSWR sweep testing, insertion loss and
TDR/FDR plots.
The Andrew Institute welcomes the opportunity to serve the industry.
We can bring select courses to your facility, or you can come to
any one of our seven convenient training locations.
For more information visit our Web site at: www.andrew.com
Registration is available online or call: +1-708-873-2644
More customers are mandating that
technicians installing their systems
are registered as having completed
Andrew Institute training.
Orland Park, Illinois USA
Lochgelly, Scotland
Coignieres, France
Sorocaba, Brazil
Sandton, South Africa
Suzhou, China
services
28
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 28
29
Quarterwave Stub Surge Arrestors
Considerations and Selection
Quarterwave Stub (QWS) Surge Arrestor Technology
An understanding of the key concepts of quarterwave stub technology and
its relationship to lightning transients can be of great benefit to transmission
line system designers and operators. With this understanding, system
designers and operators can more fully utilize lightning protection systems
that use QWS technology as well as understand the critical role multistrike
ability plays in lightning protection systems.
Arrestor Plus

T-Series Surge Arrestors from Andrew Corporation employ


quarterwave stub (QWS) technology, a unique design that allows
microwave signals to pass unattenuated while shunting the lower
frequencies associated with lightning-induced transients to ground. This
proven QWS technology is utilized in APT Arrestor Plus

Surge Arrestors.
To understand QWS technology, one needs to understand lightning.
The lightning transient is characterized by a current waveform with an
8-microsecond rise time (time to reach 90% of the peak value) and
a 20-microsecond decay time (time to decay to 50% of the peak value).
Peak currents can reach excessive values, but 50% of all strikes will reach
values of only 18 kA. It is important to remember that this is only
a laboratory characterization of the lightning transient, but it facilitates
standardized testing techniques for the industry. Figure 1 depicts an actual
laboratory-generated 8/20 sec waveform that was used to evaluate
Andrew Surge Arrestors. For more detailed information regarding
laboratory generated surge waveforms, see IEC 60-2,
ANSI-IEEE Std 4-1978, and ANSI C62.1-1984.
The substantial energy associated with lightning transients has frequency
components near dc with components of decreasing value of energy
extending through 160 kHz.
The effectiveness of surge arrestors is characterized by the throughput
energy and the ability to withstand multiple surges. These characteristics
are readily measurable in a laboratory equipped with the appropriate test
equipment. Throughput energy is a measure of the amount of energy
passed through the output of the device when the input of the device is
subjected to a lightning transient waveform. The throughput energy can
be calculated from the residual voltage waveform using the relationship:
Figure 2 shows the residual output voltage present when an APT Series
Surge Arrestor was subjected to an actual 8/20 sec waveform with a
peak current of 20 kA. In this case, the residual voltage was recorded
across a 50 ohm load. The resulting throughput energy was 72
microjoules. The objective of the surge arrestor is to minimize the
throughput energy to a manageable level. Most microwave transmitters
and receivers used in todays wireless systems are capable of
withstanding throughput energy levels of 10 millijoules or less.
The ability to withstand multiple strikes is also an important measure
of surge arrestor merit. Multistrike ability is measured by subjecting the
QWS surge arrestors to repeated surges and observing if the arrestors
continue to properly function or show signs of degradation. No evidence
of failure or degradation was observed after subjecting the Andrew
Arrestor Plus

Surge Arrestors to over 100 strikes at 50 kA peak current


using an 8/20 sec waveform. This level of reliability is essential
in protecting todays telecommunications systems from the potential
of damaging lightning transients.
Arrestor Plus QWS Surge Arrestors are carefully designed and tested
to provide a low impedance path to ground for any lightning induced
transient energy present on the center conductor of the transmission line.
These surge arrestors are designed to withstand multiple strikes of the most
severe surges. The unique attributes of QWS surge arrestors are made
possible by careful design and selection of the geometry and
cross-sectional area of the conductors that make up the shorting stub.
QWS designs result in extremely low throughput energy devices with
true multistrike ability.
When selecting a surge arrestor, the RF performance must be considered.
Characteristics that describe RF performance are operating bandwidth,
VSWR (return loss), insertion loss, maximum average power, and passive
intermodulation distortion.
The operating bandwidth of quarterwave shorted stubs is limited,
but Andrew Arrestor Plus QWS Surge Arrestors are designed to
accommodate the operating bandwidth requirements of todays wireless
telecommunications systems. Quarterwave shorted stubs can be designed
to accommodate up to 20% bandwidth. The bandwidth characteristics of
the surge arrestors is similar to that of a bandpass filter: RF signals at the
center of the band pass unattenuated, while out-of-band signals (such as
lightning transients) are diverted harmlessly to ground.
Appendix 1
appendixes
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 29
Appendix 1
Figure 3 shows the measured wideband S11 (return loss) of a QWS
surge arrestor. Note that in the band of interest, the S11 levels are
typically -30 dB.
It is key to note that dc signals cannot be passed through the device.
When dc passing is required, as is often the case for tower top active
electronics, then it is strongly recommended to use Andrew APG Gas
Tube Series Surge Arrestors. For more information on APG Gas Tube
Series Arrestors, see Appendix 2.
The lowest center frequency of operation is limited to approximately
400 MHz, while the highest center frequency is limited by the cutoff
frequency of the coaxial cable being used. Figure 4 shows a cross-
sectional view of a QWS Surge Arrestor. The lower operating frequency
is limited due to the physical size of the shorting stub. When the shorting
stub reaches too long of a physical length, the stub appears as an
inductive load, resulting in excessive residual voltages. Quarterwave
shorted stubs can be designed to accommodate systems operating as
high as 12 GHz.
In the operating bandwidth of the Arrestor Plus

QWS Surge Arrestors,


the RF performance characteristics are optimal. At the operating
frequencies of the Arrestor Plus, the insertion loss is less than 0.1 dB,
no more than adding a connector to the transmission line path. Figure 5
shows the measured S21 (insertion loss) performance of an APM type
QWS surge arrestor. Note that in the band of interest, the S21 levels are
better than -0.05 dB.
The maximum average operating power of the Arrestor Plus QWS
Surge Arrestor is limited by the connector interface. The suggested
maximum average operating power for type N connectors is 600 watts
at 900 MHz. The suggested maximum average operating power for
7-16 DIN connectors is 3000 watts at 900 MHz. Exceeding these
values can result in excessive temperature rise and permanent damage to
the device. For more information regarding connector power rating,
see Andrew Catalog 38.
Intermodulation distortion (IMD) is a major concern in today's PCS,
cellular, ESMR, and other wireless systems. IMD is caused by nonlinear
effects within a device. For connectors, these nonlinear effects can be
caused by poor contact between internal surfaces, plating with ferrous
materials, such as nickel, or by oxide build up between contact surfaces.
Arrestor Plus

Surge Arrestors are designed with high pressure


contacts, premium platings, and are compensated to offer the best
possible IMD performance.
The functionality of Arrestor Plus QWS Surge Arrestors can be readily
evaluated by using ordinary RF field test equipment. If there is no
degradation of the VSWR or insertion loss of the arrestor, then the surge
arrestor is reassuringly functioning as a transient lightning protection
device. VSWR and insertion loss measurements can be made by using
vector or scalar network analyzers as well as a variety of other readily
available field test equipment. No other maintenance is required. As
obvious as it may seem, surge arrestors should never be installed
or tested when a storm is occurring or approaching.
System requirements often dictate outdoor installation of surge arrestors.
Arrestor Plus Surge Arrestors are ideal for these applications and designed
to withstand the harshest environments and are extensively tested to meet
industry standard specifications for waterproofing, vibration, thermal
cycling, mechanical shock, salt spray, fungus, and moisture resistance.
QWS Surge Arrestors are excellent choices for wireless base station
applications where superior RF performance is required to ensure
call quality and when protection against multiple lightning strikes
is of primary importance.
Figure 4
appendixes
30
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 30
Gas Discharge Tube Protectors Considerations
and Selection
Gas Tube Surge Arrestor Technology
To simplify selecting the appropriate gas tube for your system plots,
maximum average power vs. VSWR have been compiled. Figures 1 and
2 show plots of maximum average power vs. VSWR for 90 and 350 volt
gas tubes. Each graph shows different values of commonly used dc bias
voltages. These graphs were established from extensive laboratory testing
and include the appropriate safety factors to ensure proper gas tube
selection. Using these graphs for selecting a gas tube will optimize the
level of protection required for your system.
Gas tube elements are offered in various spark-over voltages. Andrew
Corporation simplifies the selection process by limiting the users choice to
two options, 90 volt for GPS applications and 350 volt for many other
wireless applications requiring a dc bias. Plots of maximum average
power vs. VSWR have been compiled for the 90 and 350 volt gas tubes
from extensive laboratory testing and have built-in safety factors to ensure
proper selection. See figures 3 and 4. Each graph shows several different
values of commonly used dc bias voltages. Using these graphs for
selecting a gas tube will optimize the level of protection required for your
system.
When working in todays environment of diplexed signals, overlaid
networks, tower mounted amplifiers, and multiple carriers, it is necessary
to verify that a systems maximum average power does not exceed that
rating for the gas tube. The following example illustrates the process of
using the voltage derating curves that follow.
2. Calculate the peak instantaneous voltage of a two,
+42dBm carrier, 50 ohm based system
Peak instantaneous voltage (volts): =
V peak per carrier (volts) number of carriers (N)
Peak instantaneous voltage (volts) = 80
Therefore, the peak instantaneous voltage of a two
+42dBm carriers is 80 volts.
3. Calculate the peak instantaneous power of two,
+42dBm carrier, 50 ohm based system
Peak instantaneous power (watts): =
(Peak instantaneous voltage (volts))
2
Impedance (ohms)
Peak instantaneous power (watts) = 128
Peak instantaneous power (dBm): =
Peak instantaneous power (watts)
0.001

Peak instantaneous power (dBm) = 51.072


Therefore, the peak instantaneous power of two,
+42dBm carriers is 128 watts (+51dBm).
10log
4. The gas tube selection curves are specified as Maximum
Average Power vs. VSWR. Therefore, it is required to
calculate an estimate of the average (RMS) power from the
peak instantaneous power. A reasonable calculation of this
estimate is shown below:
Peak instantaneous voltage (volts) = 80
RMS equivalent (volts):=
Peak instantaneous voltage (volts)
2
RMS equivalent (volts)= 56.569
RMS equal power (watts): =
(RMS equivalent (volts))
2
Impedance (ohms)
RMS equal power (watts) = 64
Therefore, to utilize the gas tube selection curves, an
approximate value of 64 watts average power would provide
a reasonable estimate.
Note that for this calculation, the dc bias voltage was not
specified and the VSWR was not specified. The gas tube
selection curves provide a derating for both the VSWR and
dc bias voltage.
31
Appendix 2
1. Calculate the peak instantaneous voltage of a single
+42dBm carrier for a 50 ohm based system
V rms per carrier (volts): =
average power per carrier (watts) Impedance (ohms)
V rms per carrier (volts) = 28.284
V peak per carrier (volts) : = 2V rms per carrier (volts)
V peak per carrier (volts) = 40
Therefore, the peak instantaneous voltage of a single
+42dBm carrier is 40 volts.
1000
Average Power
per Carrier (watts) =
10
(average power per carrier in dBm/10)
Using the Maximum Average Power Derating Curves
GSM Radio Operating Conditions:
1. Number of carriers = 2
2. Power of each carrier (dBm) = +42 dBm carriers at the
output of a hybrid combiner (+45 dBm at combiner input)
3. VSWR = 1.25:1
4. dc Bias = 15V
5. Nominal Impedance = 50
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 31
Appendix 2

3.25W
Vdc Bias = 15V
Derating of Maximum Average Power due to VSWR and
Applied dc-bias for APG Arrestor Plus Surge Arrestors
with 90 Volt Gas Tubes
Vdc bias = 0 volts
Vdc bias = 5 volts
Vdc bias = 12 volts
Vdc bias = 24 volts
1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0
VSWR
Figure 1
A
v
e
r
a
g
e

P
o
w
e
r

(
W
a
t
t
s
)
12
11
10
9
8
7
6
5
4
3
2
1
0
1.25
Steps
1. Apply system parameters to 90V curves.
2. Estimate 15V dc bias line
3. Find Average Power level at intersection with 1.25 VSWR
4. Average Power = 3.25W
5. 3.25W is much less than 64W therefore 90V gas tube is not chosen
for this application.
6. Move on to 350V curve.

Derating of Maximum Average Power due to VSWR and
Applied dc-bias for APG Arrestor Plus Surge Arrestors
with 90 Volt Gas Tubes
Vdc bias = 0 volts
VSWR
Figure 2
A
v
e
r
a
g
e

P
o
w
e
r

(
W
a
t
t
s
)
Vdc bias = 5 volts
Vdc bias = 12 volts
Vdc bias = 24 volts
Vdc bias = 15 volts
375W
Steps:
1. Locate Maximum Average Power for System with VSWR=1.25 and
Vdc =15V as before.
2. Maximum Average Power (est.) = 375W (+55.74 dBm)
3. Estimated Average Power (from calculation) = 64W (+48.06 dBm)
4. Resulting safety margin is 7.68 dB.
5. 350V gas tube is chosen due to acceptable safety margin.
The APTDC line of dc passing surge arrestors should be used for those
cases where the intersection of VSWR and Maximum Average Power
lie above the 0 volt dc offset curve.
Gas Tube Derating Curves
90 Volt
Figure 3
350 Volt
Figure 4
appendixes
32
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 32
Andrew Arrestor Plus

Gas Tube Surge Arrestors allow field replacement


of gas tube elements. Gas tubes can be replaced by simply removing the
nut and replacing the element. A gas tube element may not always show
outward signs of failure or degradation, therefore, routine maintenance
and inspection is suggested. If the number of storms in an area is high,
gas tube elements should be replaced more frequently. Gas tube
degradation is dependent on the number as well as the intensity of the
lightning strikes. As obvious as it may seem, gas tube elements should
never be replaced when a storm is occurring or approaching.
When selecting a surge arrestor, the RF performance must be considered.
Characteristics that describe RF performance are operating bandwidth,
VSWR (return loss), insertion loss, and maximum average power.
Arrestor Plus Gas Tube Arrestors offer the widest bandwidth available of
any gas tube surge arrestors on the market. Unlike quarter wave stub
arrestors, Andrew APG Gas Tube Arrestors can be used for applications
under 400 MHz. A single unit can be used for broadband applications
over the full frequency range of 0 2000 MHz. Figure 5 shows the
measured wideband S11 return loss plot of a gas tube surge arrestor.
Note that in the commonly used 800 960 MHz and 1700 2000
MHz bands, the S11 levels are typically better than 30 dB.
Over the operating frequencies of the Arrestor Plus, the insertion loss is
less than 0.1 dB, no more than adding a connector to the transmission
line path. Figure 6 shows the measured S21 (insertion loss) performance
for a typical APG family arrestor. Note that in the commonly used
800-960 MHz and 1700-2000 MHz bands, the S21 levels are
typically 0.05 dB and 0.12 dB, respectively.
33
Appendix 2
Unlike QWS arrestors, a gas tube arrestor can pass dc current along the
center conductor, as is often required for todays wireless communication
systems incorporating tower top active electronics.
VSWR and insertion loss measurement of APG Gas Tube Surge Arrestors
can be made by using vector or scalar network analyzers as well as
a variety of other readily available types of field test equipment. The
arrestors are dc passing broadband devices and can therefore be
used with time domain reflect meters or fault location equipment.
System requirements often dictate that surge arrestors will be installed
outdoors. The Arrestor Plus APG Series Surge Arrestors from Andrew
are ideal for these applications and are designed to withstand the
harshest environment. They are extensively tested to meet industry
standard specifications for waterproofing, vibration, thermal cycling,
mechanical shock, salt spray, fungus, and moisture resistance.
Andrew Arrestor Plus gas tube surge arrestors are an excellent choice
for broadband frequency applications or when a dc bias is required
for providing power to tower top devices. Please visit our website at
www.andrew.com for product data sheets and electronic copies of
this appendix.
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 33
Appendix 3
dc Passing T-Series Arrestors
Andrew Arrestor Plus

, dc Passing Surge Arrestors (US Patent Pending) are


true broadband RF devices that are capable of allowing a
dc bias to pass along the center while shorting the lower frequencies
associated with lightning induced transients to the outer conductor and
to earth ground. By removing the gas tube from the RF path, they allow
dc voltage to pass and greatly enhance power handling capability.
Arrestor Plus

, dc Passing, Wideband Surge Arrestors are the same


general shape and size as a typical quarterwave surge arrestors. The
arrestor is comprised of two coaxial connector interfaces joined by a
center conductor passing through a coaxial arrestor body. A shorting stub
connects to the center conductor on an axis perpendicular to the center
conductor through a port in the arrestor body. A gas discharge tube sits
directly on top of the RF shorting stub, under constant pressure applied by
the gas tube spring clip. The shorting stub, RF shorting stub, gas tube and
gas tube spring clip are sealed inside of the shorting stub sleeve and
arrestor body by compressing an o-ring between the screw-in gas cap
and the shorting stub sleeve.
The function of the various elements in the dc passing T-series surge
arrestor described above are best understood if modeled as a simple
electronic circuit as shown in figure 2, below.
Figure 2
Electronic Circuit Diagram of dc Passing Wideband Surge Arrestor
The two coaxial connector interfaces, ports P1 and P2, provide coupling
to coaxial cables that run between the output of the radio equipment and
the surge arrestor and the surge arrestor and the antenna. This cable is
indicated as having a nominal impedance (Zo) of 50. The center
conductor sections that are between the coaxial connector interfaces and
the shorting stub are modeled as transmission lines TL1 and TL2. The
shorting stub is modeled as an inductor (L1) that connects to the center
conductor between TL1 and TL2. The outer surface of the RF Shorting
Stub is coated with a dielectric material to create a series capacitance
(C1) between the end of the helical shorting stub and the shorting stub
sleeve, which is a ground (G1). A gas discharge tube with capacitance
(C2) sits in parallel with capacitor C1 and ground (G2). The inductance,
L1, of the helical shorting stub and the effective capacitance of parallel
capacitors C1 and C2 tune the surge arrestor giving it a broadband
frequency response.
Under normal operating conditions, the RF signal will pass straight from
P1 to P2 since the inductor, L1, appears as an open circuit. When a dc
bias voltage is applied at either P1 or P2, it will also pass straight
through the device. The dc bias voltage is prevented from shorting to
either earth grounds, G1 or G2, by capacitors, C1 and C2, because
these capacitors appear as open circuits to low current dc bias voltages
typically applied to power tower mounted amplifiers or active antennas.
The gas in the gas discharge tube will ionize under lightning strikes or
other high voltage conditions allowing the transient to go from the center
conductor to the outer conductor or ground (G2). For purposes of
effective grounding, the surge arrestor can either be mounted to ground
through a bulkhead interface or by mounting the surge arrestor to a
copper grounding bus bar via threaded mounting hardware that is
provided with the surge arrestor or ordered separately.
appendixes
34
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 34
35
Definitions/Comments
Isokeraunic Level: The isokeraunic level is a measure of the number of
thunderstorm days per year. A thunderstorm day is defined as a day on
which thunder is heard. For example, the city of Chicago averages 41
thunderstorm days per year. The isokeraunic level is expressed as:
T
y
= Isokeraunic Levels
Total Flash Density: The total flash density is a measure of the number of
flashes per year per square kilometer. For example, the city of Chicago
averages 33 flashes per year per square kilometer. Total flash density
includes intracloud flashes, intercloud flashes and cloud-to-ground flashes.
Total flash density can be expressed as DT . The expression for total flash
density is an empirically determined value based on many years of
observation and can be approximated as follows:
D
T
0.02 x T
y
2
Ground Flash Density: The ground flash density is a measure of the
number of flashes that reach the ground (as opposed to intercloud and
intracloud type flashes). Flashes that reach the ground are the ones that
are threatening to us. For example, the city of Chicago averages 9.9
ground flashes per year per square kilometer. The expression for ground
flash density is an empirically determined value based on many years of
observation and can be expressed as follows:
D
Ground Flash
= P
fraction
x D
T
is the fraction of total flashes that reach the ground. The value is related to
the latitude as expressed in the following equation:
P
fraction
= 0.1 x [1 + (
latitude
)
2
] 30
Area of Attraction of a Structure: A structure has a defined attraction
area that is strongly dependent on the height and less dependent on its
width and length. For a structure of height H, length L, and width W, the
area of attraction (sometimes referred to as area of collection) can be
estimated by using the following equation. All units are in meters. Note
that if the structure has a small length or small width as compared to the
height, such as a communications tower or pole, then the equation is
dominated by the height.
Area
C
= L W = 4.4 H (L + W) + (2.2 H)
2
Average Number of Strikes per Year to a Tower: The average number of
strikes per year for an arbitrary tower of height H, length L and width W,
can be estimated by multiplying the Area of Attraction, AreaC, by the
Ground Flash Density, D Ground Flash. Since the Area of Attraction, is expressed in
square meters and the Ground Flash Density is expressed in square
kilometers, a factor of 10
-6
must be included.
S

Area
c
x D
Ground Flash
x H
2
x 10
-6
Strikes per Year, 50 foot tower: As an example, a 50-foot tower in
the Chicago area will average 0.040 strikes per year (or this can be
interpreted as 1 strike every 24.6 years). The calculations were based
on a 50-foot (15.24 meters) height, 3.5-meter width, 3.5-meter length,
latitude of 42 degrees, and an isokeraunic level of 41 thunderstorm
days per year.
Strikes per Year, 100 foot tower: As an example, a 100-foot tower
in the Chicago area will average 0.153 strikes per year (or this can
be interpreted as 1 strike every 6.5 years). The calculations were based
on a 100-foot (30.48 meters) height, 3.5-meter width, 3.5-meter length,
latitude of 42 degrees, and an isokeraunic level of 41 thunderstorm
days per year.
Strikes per Year, 200 foot tower: As an example, a 200-foot tower
in the Chicago area will average 0.591 strikes per year (or this can be
interpreted as 1 strike every 1.7 years). The calculations were based
on a 200-foot (60.96 meters) height, 3.5-meter width, 3.5-meter length,
latitude of 42 degrees, and an isokeraunic level of 41 thunderstorm
days per year.
It is important to remember that these are statistical calculations based on
many years of observation. When lightning strikes within even a few
kilometers of the tower, damaging transients can be coupled and carried
on any transmission lines, data lines, and power lines in the vicinity and
cause damaging effects within the area of the tower.
References
1 IEC 1312-1, Protection Against Lightning Electromagnetic Impulse
2 IEEE C62.41-1991, IEEE Recommended Practice on Surge Voltages in Low-Voltage ac Power Circuits
3 MIL-STD-188-124A, Military Standard for Grounding, Bonding and Shielding
4 MIL-HDBK-419A, Military Handbook for the Theory of Grounding, Bonding and Shielding of
Communications Electronics. Volume 1 (Basic Theory), Volume 2 (Applications)
5 MIL-STD-1757A, Lightning Qualification Test Techniques for Aerospace Vehicles and Hardware
6 National Electric Code 1993, Article 280
7 IEC 1024-1, Protection of Structures Against Lightning.
8 BS 6651, 1992 Code of Practice for Protection of Structures Against Lightning
9 Aleksa, J. and Stockman, C., A Flash of Beauty or a Force for Destruction?,
South African Wireless Communications, Aug 1997
10 Fisher, F.A. and Plumer, J.A., Lightning Protection of Aircraft, Lightning Technologies, 1990
Appendix 4
Isokeraunic Flash Ground Strikes per Year: Strikes per Year: Strikes per Year:
Location Level Latitude Density Flash Density 50-foot tower 100-foot tower 200-foot tower
Chicago, IL 41 42 33.60 9.95 0.041 0.153 0.591
Arlington, TX 48 33 46.10 9.85 0.040 0.151 0.585
Atlanta, GA 50 34 50.00 11.30 0.046 0.173 0.671
Tampa, FL 100 28 200.00 35.00 0.143 0.537 2.081
York, UK 9 53 1.62 0.67 0.003 0.010 0.039
Taiwan 20 23 8.00 1.27 0.005 0.019 0.075
Hong Kong 30 23 18.00 2.85 0.012 0.043 0.170
Singapore 140 2 392.00 39.30 0.160 0.604 2.340
Rio de Janeiro 60 23 72.00 11.40 0.046 0.175 0.679
P
fraction
P
fraction
Lightning Strike Statistics and Definitions
Statistics on the Probability of a Lightning Strike to Towers of Various Heights in Various Locations on Earth
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 35
Appendix 5
Cable Hoisting and Attachment Bulletin Number/SP
Support/ Hoisting Grips for HELIAX

Cables 237409
Hoisting Grips 17262
Click-On Hangers 3969A
Click-On Hangers 237397
KwikClamp Hangers 10164
Standard Hanger Kits 37378
Type 31766A Hanger Kits 17783
Hanger Kits 37321
Round Member Adapter Kit (Click-On Hangers) 237515
Hoisting Grip and Cable Support Hangers (SP30-45)
Compact Angle Adapters 10140
Angle Adaptors (types 31768A, 243684, 243684-M) 237363
Hanger spacing guide lines 10883
Tools
HELIAX

Connector Tool Kit 237274


Tool Box 1971A
Tool Box Configurations 10147
EASIAX

Plus Cable Prep Tool L5, L6, L7 10267


EASIAX

Plus Cable Prep Tool FSJ4 10197


Wrench Kits 10234
Securing Coaxial Cable in a Monopole 10236
Andrew Installation Tools 10988
Weatherproofing
3M Cold Shrink Weatherproofing Kits 237272
3M Cold Shrink Weatherproofing Kits 237426
Application Details for 3M Cold Shrink Kits (SP50030)
Connector/Splice Weatherproofing Kit 237133
Weatherproofing Enclosures (SP50414)
Weatherproofing Enclosures 237799
Weatherproofing Enclosures for In Line Connectors 10907
WeatherShield Publication TP-100257-EN
WeatherShield New Product Announcement PA-100428-EN
Cable Entry System
Cabinet Feed-Thru Plates for 1/2" through 1-5/8" 237362
Types 204673 and 48940 Wall/Roof Feed Thru Plates 237060
Single Entrance Wall/Roof Feed-Thru Kits 37007
ArrestorPort II Entry/Ground System 237516
Grounding
Universal Grounding Bar 237440
Universal Ground Bar Assembly 237513
Compact SureGround Testing Performance SP50365-A
Compact SureGround Kits 10725
Compact SureGround instruction bulletin 237700
Sureground instruction bulletin 237549
Standard grounding kits instruction bulletin 237549
Connector grounding kit 237701
Andrew Accessory Products Information
Documents Available For Additional Information
The table below lists Andrew Installation Instructions and Special Publications (SP) for the products mentioned in this guide.
Available from www.andrew.com (see page 27)
appendixes
36
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 36
37
Appendix 6
Cable Hanger
Cable Size Type Number Type Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed: 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice: No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
1/2" LDF4-50A 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)
1/2" LDF4-75A 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)
1/2" HL4RP-50 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)
1/2" HJ4-50 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)
1/2" HLT4-50 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 3 (0.9) 2 (0.6)
1/2" HT4-50 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)
1/2" HST4-50 43211A 5 (1.5) 3 (0.9) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" HS4RP-50 43211A 5 (1.5) 3 (0.9) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" FSJ4-50B 43211A 5 (1.5) 3 (0.9) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1/2" FSJ4-75A 43211A 5 (1.5) 3 (0.9) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
5/8" LDF4.5-50 42396A-9 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
5/8" HJ4.5-50 42396A-9 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
7/8" AVA5-50 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
7/8" LDF5-50A 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
7/8" HJ5-50 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
7/8" HJ5-75 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
7/8" HT5-50 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)
1-1/4" LDF6-50 42396A-1 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9)
1-5/8" AVA7-50 42396A-2 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
1-5/8" LDF7-50A 42396A-2 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
1-5/8" HJ7-50A 42396A-2 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
2-1/4" LDF12-50 42395A-4 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
2-1/4" HJ12-50 42396A-4 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)
3" HJ8-50B 31766A-11 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
4" HJ11-50B 31766A-10 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
5" HJ9HP-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
5" HJ9-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees).
Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occurring simultaneously. 2. Wind speeds are maximum, which includes gust factors
and exposure factors.
Cable Hanger Spacing
Revision: February 2005; added elliptical waveguide hangers
Recommended maximum hanger spacings are tabulated below for
various wind speed and ice conditions. The recommendations are based
on guidelines stated in EIA Standard RS-222 and new wind tunnel and
vibration tests. They are current as of January 2003 and supersede those
in previous Andrew catalogs. Please refer to Andrew publication number
10883 available at www.andrew.com for the most current
recommendations.
Standard Hangers - Maximum Hanger Spacing
(Note: Standard tower configuration spacing is 3 to 4 ft)
These spacing recommendations assume that all hangers are properly
installed and tightened.
Installations in Typical Climates. Use the 125 mph (200 km/h), 1/2"
ice conditions, highlighted in red in the table.
Severe or Mild Climates. Use the wind speed and ice conditions that
most closely approximate the expected worst case conditions for the
local climate.
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 37
38
Cable Hanger
Cable Size Type Number Type Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed: 125 mph (200 km/h) 150 mph (240 km/h)
Radial Ice: No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
1/2" 1LDF4-50A 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" LDF4-75A 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HL4RP-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HJ4-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HLT4-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HT4-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HST4-50 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" HS4RP-50 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" FSJ4-50B 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
1/2" FSJ4-75A 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)
5/8" LDF4.5-50 42396A-9 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 3 (0.9)
5/8" HJ4.5-50 42396A-9 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 3 (0.9)
7/8" AVA5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" LDF5-50A 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" HJ5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" HJ5-75 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
7/8" HT5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)
1-1/4" LDF6-50 42396A-1 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
1-5/8" AVA7-50 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" LDF7-50A 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
1-5/8" HJ7-50A 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)
2-1/4" LDF12-50 42395A-4 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
2-1/4" HJ12-50 42396A-4 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
3" HJ8-50B 31766A-11 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
4" HJ11-50B 31766A-10 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
5" HJ9HP-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
5" HJ9-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees).
Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occurring simultaneously. 2. Wind speeds are maximum, which includes gust factors
and exposure factors.
Appendix 6
Standard Hangers - Maximum Hanger Spacing (Note: Standard tower configuration spacing is 3 to 4 ft.)
appendixes
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 38
Appendix 6
Snap-In Hangers - Recommended Maximum Hanger Spacing
Cable Hanger
Cable Size Type Number Type Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed: 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice: No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
1/2" LDF4-50A SSH-12 4 (1.22) 4 (1.22) 3 (0.91) 4 (1.22) 3 (0.91) 2 (0.61)
1/2" LDF4-75 SSH-12 4 (1.22) 4 (1.22) 3 (0.91) 4 (1.22) 3 (0.91) 2 (0.61)
1/2" FSJ4-50B SSH-12 4 (1.22) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 2 (0.61)
1/2" FSJ4-75A SSH-12 4 (1.22) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 2 (0.61)
1/2" HL4RP-50 SSH-12 4 (1.22) 4 (1.22) 3 (0.91) 4 (1.22) 3 (0.91) 2 (0.61)
1/2" HLT4-50 SSH-12 4 (1.22) 4 (1.22) 3 (0.91) 4 (1.22) 3 (0.91) 2 (0.61)
1/2" HS4RP-50 SSH-12 4 (1.22) 4 (1.22) 3 (0.91) 4 (1.22) 3 (0.91) 2 (0.61)
1/2" HST4-50 SSH-12 4 (1.22) 4 (1.22) 3 (0.91) 4 (1.22) 3 (0.91) 2 (0.61)
1/2" HT4-50 SSH-12 4 (1.22) 4 (1.22) 3 (0.91) 4 (1.22) 3 (0.91) 2 (0.61)
1/2" HJ4-50 SSH-12 4 (1.22) 4 (1.22) 3 (0.91) 4 (1.22) 3 (0.91) 2 (0.61)
5/8" LDF4.5-50 206706A-6 4 (1.22) 4 (1.22) 3 (0.91) 4 (1.22) 3 (0.91) 2 (0.61)
7/8" AVA5-50 SSH-78 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61)
7/8" LDF5-50A SSH-78 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61)
7/8" HJ5-50 SSH-78 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61)
7/8" HJ5-75 SSH-78 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61)
7/8" HT5-50 SSH-78 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61)
7/8" FT5-50T SSH-78 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61)
1-1/4" LDF6-50 SSH-114 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61)
1-5/8" AVA7-50 SSH-158 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61)
1-5/8" LDF7-50A SSH-158 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61)
1-5/8" HJ7-50A SSH-158 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61)
2-1/4" LDF12-50 206706A-5 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61)
Wind Speed: 125 mph (200 km/h) 150 mph (240 km/h)
Radial Ice: No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
1/2" LDF4-50A SSH-12 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 1 (0.30)
1/2" LDF4-75 SSH-12 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 1 (0.30)
1/2" FSJ4-50B SSH-12 3 (0.91) 2 (0.61) 1 (0.30) 2 (0.61) 2 (0.61) 1 (0.30)
1/2" FSJ4-75A SSH-12 3 (0.91) 2 (0.61) 1 (0.30) 2 (0.61) 2 (0.61) 1 (0.30)
1/2" HL4RP-50 SSH-12 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 1 (0.30)
1/2" HLT4-50 SSH-12 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 1 (0.30)
1/2" HS4RP-50 SSH-12 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 1 (0.30)
1/2" HST4-50 SSH-12 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 1 (0.30)
1/2" HT4-50 SSH-12 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 1 (0.30)
1/2" HJ4-50 SSH-12 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 1 (0.30)
5/8" LDF4.5-50 206706A-6 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61) 1 (0.30)
7/8" LDF5-50A SSH-78 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 1 (0.30) 1 (0.30)
7/8" HJ5-50 SSH-78 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 1 (0.30) 1 (0.30)
7/8" HJ5-75 SSH-78 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 1 (0.30) 1 (0.30)
7/8" HT5-50 SSH-78 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 1 (0.30) 1 (0.30)
7/8" FT5-50T SSH-78 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 1 (0.30) 1 (0.30)
1-1/4" LDF6-50 SSH-114 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 1 (0.30) 1 (0.30)
1-5/8" LDF7-50A SSH-158 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 1 (0.30) 1 (0.30)
1-5/8" HJ7-50A SSH-158 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 1 (0.30) 1 (0.30)
2-1/4" LDF12-50 206706A-5 2 (0.61) 2 (0.61) 1 (0.30) 2 (0.61) 1 (0.30) 1 (0.30)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees).
Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occurring simultaneously. 2. Wind speeds are maximum, which includes gust factors
and exposure factors.
39
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 39
Click-On Hangers Recommended Maximum Hanger Spacing
Cable Hanger Type* and
Cable Size Type Number Stack Configuration Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed: 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice: No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
1/2" LDF4-50A L4CLICK, 1-Stack 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91)
1/2" LDF4-50A L4CLICK, 2-Stack 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91)
1/2" LDF4-50A L4CLICK, 3-Stack 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91)
Note: These same hanger spacing recommendations apply for the other following 1/2" cable types: LDF4-75A, HL4RP-50, HLT4-50, HS4RP-50, HST4-50, HT4-50, HJ4-50
5/8" LDF4.5-50 L45CLICK, 1-Stack 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91)
5/8" LDF4.5-50 L45CLICK, 2-Stack 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91)
5/8" LDF4.5-50 L45CLICK, 3-Stack 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91)
Note: These same hanger spacing recommendations apply for the other following 5/8" cable types: HJ4.5-50 and AVA5-50
7/8" AVA5-50 L5CLICK, 1-Stack 4 (1.22) 4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91)
7/8" LDF5-50A L5CLICK, 1-Stack 4 (1.22) 4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91)
7/8" LDF5-50A L5CLICK, 2-Stack 4 (1.22) 4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91)
7/8" LDF5-50A L5CLICK, 3-Stack 4 (1.22) 4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91)
Note: These same hanger spacing recommendations apply for the other following 7/8" cable types: VXL5-50, HJ5-50, HJ5-75, HT5-5.
1-1/4" LDF6-50 L6CLICK, 1-Stack 4 (1.22) 4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91)
1-1/4" LDF6-50 L6CLICK, 2-Stack 4 (1.22) 4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91)
1-1/4" LDF6-50 L6CLICK, 3-Stack 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91)
1-5/8" AVA7-50 L7CLICK, 1-Stack 4 (1.22) 4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91)
1-5/8" LDF7-50A L7CLICK, 1-Stack 4 (1.22) 4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91)
1-5/8" LDF7-50A L7CLICK, 2-Stack 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91)
1-5/8" LDF7-50A L7CLICK, 3-Stack 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91)
Note: These same hanger spacing recommendations apply for the other following 1 5/8" cable types: HJ7-50A and AVA7-50.
Wind Speed: 125 mph (200 km/h) 150 mph (240 km/h)
Radial Ice: No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
1/2" LDF4-50A L4CLICK, 1-Stack 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61)
1/2" LDF4-50A L4CLICK, 2-Stack 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61)
1/2" LDF4-50A L4CLICK, 3-Stack 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61)
Note: These same hanger spacing recommendations apply for the other following 1/2" cable types: LDF4-75A, HL4RP-50, HLT4-50, HS4RP-50, HST4-50, HT4-50, HJ4-50
5/8" LDF4.5-50 L45CLICK, 1-Stack 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61)
5/8" LDF4.5-50 L45CLICK, 2-Stack 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61)
5/8" LDF4.5-50 L45CLICK, 3-Stack 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61)
Note: These same hanger spacing recommendations apply for the other following 5/8" cable types: HJ4.5-50
7/8" LDF5-50A L5CLICK, 1-Stack 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61)
7/8" LDF5-50A L5CLICK, 2-Stack 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61)
7/8" LDF5-50A L5CLICK, 3-Stack 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61)
Note: These same hanger spacing recommendations apply for the other following 7/8" cable types: VXL5-50, HJ5-50, HJ5-75, HT5-50
1-1/4" LDF6-50 L6CLICK, 1-Stack 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61)
1-1/4" LDF6-50 L6CLICK, 2-Stack 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61)
1-1/4" LDF6-50 L6CLICK, 3-Stack 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61)
1-5/8" LDF7-50A L7CLICK, 1-Stack 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61)
1-5/8" LDF7-50A L7CLICK, 2-Stack 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61)
1-5/8" LDF7-50A L7CLICK, 3-Stack 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61)
Note: These same hanger spacing recommendations apply for the other following 1 5/8" cable types: HJ7-50A.
* These hanger spacings have been specified based on using the Click-On Hangers with Andrew specified hardware kits. Definitions and Assumptions 1. Per EIA-222 Standard:
Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees). Combined wind and ice loading is reduced by 25% to reflect
lower probability of wind and ice occurring simultaneously. 2. Wind speeds are maximum, which includes gust factors and exposure factors.
Appendix 6
appendixes
40
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 40
41
Mini Click-On Hangers Recommended Maximum Hanger Spacing
Cable Hanger Type and
Cable Size Type Number Stack Configuration
Wind Speed: 125 mph (200 km/h)
Radial Ice: No Ice 1/2" (13 mm) 1" (25 mm)
6 mm-8 mm CNT-240, CNT-300, FSJ1 series 68MCLICK, 1-Stack 1.5 (0.61) 1.5 (0.61) 1.5 (0.61)
6 mm-8 mm CNT-240, CNT-300, FSJ1 series 68MCLICK, 2-Stack 1.5 (0.61) 1.5 (0.61) 1.5 (0.61)
6 mm-8 mm CNT-240, CNT-300, FSJ1 series 68MCLICK, 3-Stack 1.5 (0.61) 1.5 (0.61) 1.5 (0.61)
9 mm-12 mm CNT-400, LDF1, FSJ2, LDF2, EFX2 series 912MCLICK, 1-Stack 3 (0.91) 3 (0.91) 3 (0.91)
9 mm-12 mm CNT-400, LDF1, FSJ2, LDF2, EFX2 series 912MCLICK, 2-Stack 3 (0.91) 3 (0.91) 3 (0.91)
9 mm-12 mm CNT-400, LDF1, FSJ2, LDF2, EFX2 series 912MCLICK, 3-Stack 2 (0.61) 2 (0.61) 2 (0.61)
13 mm-16 mm CNT-500, CNT-600, FSJ4, LDF4 series 1316MCLICK, 1-Stack 3 (0.91) 3 (0.91) 3 (0.91)
13 mm-16 mm CNT-500, CNT-600, FSJ4, LDF4 series 1316MCLICK, 2-Stack 3 (0.91) 3 (0.91) 3 (0.91)
13 mm-16 mm CNT-500, CNT-600, FSJ4, LDF4 series 1316MCLICK, 3-Stack 2 (0.61) 2 (0.61) 2 (0.61)
* These hanger spacings have been specified based on using the Click-On Hangers with Andrew specified hardware kits.
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member
(360 degrees). Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occurring simultaneously. 2. Wind speeds are maximum,
which includes gust factors and exposure factors.
Appendix 6
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 41
Insulated Hangers Recommended Maximum Hanger Spacing
Cable Hanger
Cable Size Type Number Type Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed: 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice: No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
1/4" FSJ1-75A 11662-3 3.5 (1.07) 2 (0.61) 1.5 (0.46) 3 (0.91) 1.5 (0.46) 1 (0.30)
1/4" HST1-50 11662-3 4.5 (1.37) 2.5 (0.76) 2 (0.61) 4 (1.22) 2 (0.61) 1.5 (0.46)
1/4" LDF1-50 11662-3 4.5 (1.37) 2.5 (0.76) 2 (0.61) 4 (1.22) 2.5 (0.76) 1.5 (0.46)
3/8" EFX2-50 11662-3 5.5 (1.68) 3.5 (1.07) 2.5 (0.76) 4.5 (1.37) 3 (0.91) 2 (0.61)
3/8" ETS2-50 11662-3 5.5 (1.68) 3.5 (1.07) 2.5 (0.76) 5 (1.52) 3 (0.91) 2 (0.61)
3/8" FSJ2-50 11662-3 5.5 (1.68) 3.5 (1.07) 2.5 (0.76) 5 (1.52) 3 (0.91) 2 (0.61)
3/8" HS2RP-50 11662-3 5.5 (1.68) 3.5 (1.07) 2.5 (0.76) 5 (1.52) 3 (0.91) 2 (0.61)
3/8" HST2-50 11662-3 5.5 (1.68) 3.5 (1.07) 2.5 (0.76) 5 (1.52) 3 (0.91) 2 (0.61)
3/8" LDF2-50 11662-3 5 (1.52) 3 (0.91) 2.5 (0.76) 4 (1.22) 2.5 (0.76) 2 (0.61)
1/2" FSJ4-50B 11662-3 5.5 (1.68) 3.5 (1.07) 3 (0.91) 4.5 (1.37) 3 (0.91) 2.5 (0.76)
1/2" FSJ4-75A 11662-3 5.5 (1.68) 3.5 (1.07) 3 (0.91) 4.5 (1.37) 3 (0.91) 2.5 (0.76)
1/2" LDF4-50A 11662-3 6 (1.83) 4 (1.22) 3.5 (1.07) 5 (1.52) 3.5 (1.07) 2.5 (0.76)
1/2" LDF4-75A 11662-3 6 (1.83) 4 (1.22) 3.5 (1.07) 5 (1.52) 3.5 (1.07) 2.5 (0.76)
1/2" HL4RP-50 11662-3 6 (1.83) 4 (1.22) 3.5 (1.07) 5 (1.52) 3.5 (1.07) 2.5 (0.76)
1/2" HLT4-50 11662-3 6 (1.83) 4 (1.22) 3.5 (1.07) 5 (1.52) 3.5 (1.07) 2.5 (0.76)
1/2" HS4RP-50 11662-3 5.5 (1.68) 3.5 (1.07) 3 (0.91) 4.5 (1.37) 3 (0.91) 2.5 (0.76)
1/2" HST4-50 11662-3 5.5 (1.68) 3.5 (1.07) 3 (0.91) 4.5 (1.37) 3 (0.91) 2.5 (0.76)
1/2" HT4-50 11662-3 6 (1.83) 6 (1.83) 5.5 (1.68) 6 (1.83) 6 (1.83) 4.5 (1.37)
1/2" HJ4-50 11662-3 6 (1.83) 6 (1.83) 5.5 (1.68) 6 (1.83) 6 (1.83) 5 (1.52)
7/8" AVA5-50 11662-2 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 5.5 (1.68)
7/8" LDF5-50A 11662-2 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 5.5 (1.68)
7/8" HJ5-50 11662-2 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
7/8" HJ5-75 11662-2 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
7/8" HT5-50 11662-2 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
1-1/4" LDF6-50 33948-5 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
1-5/8" HJ7-50A 33948-3 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
1-5/8" LDF7-50A 33948-3 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
2-1/4" HJ12-50 33948-6 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
2-1/4" LDF12-50 33948-6 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
3" HJ8-50B 33948-2 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
4" HJ11-50 33948-4 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
5" HJ9-50 33948-1 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
5" HJ9HP-50 33948-1 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees).
Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occurring simultaneously. 2. Wind speeds are maximum, which includes gust factors
and exposure factors.
Appendix 6
appendixes
42
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 42
43
Insulated Hangers Recommended Maximum Hanger Spacing
Cable Hanger
Cable Size Type Number Type Number Recommended Maximum Hanger Spacing, feet (meters)
Wind Speed: 125 mph (200 km/h) 150 mph (240 km/h)
Radial Ice: No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)
1/4" FSJ1-75A 11662-3 2.5 (0.76) 1 (0.30) 1 (0.30) 2 (0.61) 1 (0.30) 0.5 (0.15)
1/4" HST1-50 11662-3 3 (0.91) 1.5 (0.46) 1 (0.30) 2.5 (0.76) 1.5 (0.46) 1 (0.30)
1/4" LDF1-50 11662-3 3 (0.91) 2.5 (0.76) 1.5 (0.46) 2.5 (0.76) 1.5 (0.46) 1 (0.30)
3/8" EFX2-50 11662-3 3.5 (1.07) 2 (0.61) 1.5 (0.46) 3 (0.91) 2 (0.61) 1.5 (0.46)
3/8" ETS2-50 11662-3 4 (1.22) 2.5 (0.76) 1.5 (0.46) 3 (0.91) 2 (0.61) 1.5 (0.46)
3/8" FSJ2-50 11662-3 4 (1.22) 2.5 (0.76) 1.5 (0.46) 3 (0.91) 2 (0.61) 1.5 (0.46)
3/8" HS2RP-50 11662-3 4 (1.22) 2 (0.61) 1.5 (0.46) 3 (0.91) 2 (0.61) 1.5 (0.46)
3/8" HST2-50 11662-3 4 (1.22) 2 (0.61) 1.5 (0.46) 3 (0.91) 2 (0.61) 1.5 (0.46)
3/8" LDF2-50 11662-3 3.5 (1.07) 2 (0.61) 1.5 (0.46) 2.5 (0.76) 1.5 (0.46) 1 (0.30)
1/2" FSJ4-50B 11662-3 3.5 (1.07) 2.5 (0.76) 2 (0.61) 3 (0.91) 2 (0.61) 1.5 (0.46)
1/2" FSJ4-75A 11662-3 3.5 (1.07) 2.5 (0.76) 2 (0.61) 3 (0.91) 2 (0.61) 1.5 (0.46)
1/2" LDF4-50A 11662-3 4 (1.22) 3 (0.91) 2 (0.61) 3 (0.91) 2.5 (0.76) 1.5 (0.46)
1/2" LDF4-75A 11662-3 4 (1.22) 3 (0.91) 2 (0.61) 3 (0.91) 2.5 (0.76) 1.5 (0.46)
1/2" HL4RP-50 11662-3 4 (1.22) 3 (0.91) 2 (0.61) 3 (0.91) 2.5 (0.76) 1.5 (0.46)
1/2" HLT4-50 11662-3 4 (1.22) 3 (0.91) 2 (0.61) 3 (0.91) 2.5 (0.76) 1.5 (0.46)
1/2" HS4RP-50 11662-3 3.5 (1.07) 2.5 (0.76) 2 (0.61) 3 (0.91) 2 (0.61) 1.5 (0.46)
1/2" HST4-50 11662-3 3.5 (1.07) 2.5 (0.76) 2 (0.61) 3 (0.91) 2 (0.61) 1.5 (0.46)
1/2" HT4-50 11662-3 6 (1.83) 5 (1.52) 3.5 (1.07) 6 (1.83) 4 (1.22) 3 (0.91)
1/2" HJ4-50 11662-3 6 (1.83) 6 (1.83) 4 (1.22) 6 (1.83) 6 (1.83) 3 (0.91)
7/8" AVA5-50 11662-2 6 (1.83) 5.5 (1.68) 4.5 (1.37) 5 (1.52) 4.5 (1.37) 3.5 (1.07)
7/8" LDF5-50A 11662-2 6 (1.83) 5.5 (1.68) 4.5 (1.37) 5 (1.52) 4.5 (1.37) 3.5 (1.07)
7/8" HJ5-50 11662-2 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 5 (1.52)
7/8" HJ5-75 11662-2 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 5 (1.52)
7/8" HT5-50 11662-2 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 5.5 (1.68)
1-1/4" LDF6-50 33948-5 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
1-5/8" AVA7-50 33948-3 6 (1.83) 6 (1.83) 5.5 (1.68) 6 (1.83) 6 (1.83) 4.5 (1.37)
1-5/8" HJ7-50A 33948-3 6 (1.83) 6 (1.83) 5.5 (1.68) 6 (1.83) 6 (1.83) 4.5 (1.37)
1-5/8" LDF7-50A 33948-3 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
2-1/4" HJ12-50 33948-6 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
2-1/4" LDF12-50 33948-6 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
3" HJ8-50B 33948-2 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
4" HJ11-50 33948-4 6 (1.83) 6 (1.83) 6 (1.83) 5 (1.52) 5 (1.52) 4.5 (1.52)
5" HJ9-50 33948-1 4.5 (1.37) 4.5 (1.37) 4.5 (1.37) 3 (0.91) 3.(0.91) 3 (0.91)
5" HJ9HP-50 33948-1 4.5 (1.37) 4.5 (1.37) 4.5 (1.37) 3 (0.91) 3.(0.91) 3 (0.91)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees).
Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occurring simultaneously. 2. Wind speeds are maximum, which includes gust factors
and exposure factors.
Appendix 6
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 43
Appendix 6
appendixes
Recommended Maximum Hanger Spacing
Standard Hangers, Outdoors for Various Wind Speed and Ice Conditions
Waveguide Hanger
Type Number Type Number Recommended Maximum Hanger Spacing, feet (m)
Wind Speed: 85 mph (137 km/h) 100 mph (160 km/h)
Radial Ice: No Ice 1/2 in (13 mm) 1 in (25 mm) No Ice 1/2 in (13 mm) 1 in (25 mm)
EW17, EWP17 31766A-9 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
EW20 31766A-10 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
EW28 31766A-11 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 5.5 (1.68)
EW34, EWP34 42396A-15 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 5.5 (1.68) 6 (1.83)
EW37, EWP37 42396A-4 6 (1.83) 6 (1.83) 5.5 (1.68) 5.5 (1.68) 5.5 (1.68) 5 (1.52)
EW43, EWP43 42396A-16 6 (1.83) 6 (1.83) 5.5 (1.68) 5 (1.52) 5 (1.52) 4.5 (1.37)
EW52, EWP52 42396A-8 5.5 (1.68) 5 (1.52) 4.5 (1.37) 4.5 (1.37) 4.5 (1.37) 4 (1.22)
EW63, EWP63 42396A-7 5 (1.52) 4.5 (1.37) 4 (1.22) 4 (1.22) 4 (1.22) 3.5 (1.07)
EW64, EWP64 42396A-11 5 (1.52) 5 (1.52) 4 (1.22) 4.5 (1.37) 4 (1.22) 3.5 (1.07)
EW77, EWP77 42396A-1 5 (1.52) 5 (1.52) 4 (1.22) 4.5 (1.37) 4 (1.22) 3.5 (1.07)
EW85 42396A-5 5.5 (1.68) 5 (1.52) 4 (1.22) 4.5 (1.37) 4 (1.22) 3.5 (1.07)
EW90, EWP90 42396A-5 5.5 (1.68) 4.5 (1.37) 4 (1.22) 4.5 (1.37) 4 (1.22) 3 (0.91)
EW127A, EWP127A 42396A-9 5.5 (1.68) 4.5 (1.37) 3.5 (1.07) 4.5 (1.37) 4 (1.22) 3 (0.91)
EW132, EWP132 42396A-9 5.5 (1.68) 4.5 (1.37) 3.5 (1.07) 5 (1.52) 4 (1.22) 3 (0.91)
EW180, EWP180 43211A 6 (1.83) 4.5 (1.37) 3.5 (1.07) 5 (1.52) 4 (1.22) 3 (0.91)
EW220 43211A 6 (1.83) 4.5 (1.37) 3.5 (1.07) 5 (1.52) 4 (1.22) 3 (0.91)
EW240 43211A 6 (1.83) 4.5 (1.37) 3.5 (1.07) 5 (1.52) 4 (1.22) 3 (0.91)
Wind Speed: 125 mph (200 km/h) 150 mph (240 km/h)
Radial Ice: No Ice 1/2 in (13 mm) 1 in (25 mm) No Ice 1/2 in (13 mm) 1 in (25 mm)
EW17, EWP17 31766A-9 6 (1.83) 6 (1.83) 5.5 (1.68) 5 (1.52) 5 (1.52) 4.5 (1.37)
EW20 31766A-10 5.5 (1.68) 5.5 (1.68) 5 (1.52) 4.5 (1.37) 4.5 (1.37) 4 (1.22)
EW28 31766A-11 5 (1.52) 5 (1.52) 4.5 (1.37) 4 (1.22) 4 (1.22) 3.5 (1.07)
EW34, EWP34 42396A-15 4.5 (1.37) 4.5 (1.37) 4 (1.22) 4 (1.22) 3.5 (1.07) 4 (1.22)
EW37, EWP37 42396A-4 4.5 (1.37) 4.5 (1.37) 4 (1.22) 3.5 (1.07) 3.5 (1.07) 3 (0.91)
EW43, EWP43 42396A-16 4 (1.22) 4 (1.22) 3.5 (1.07) 3.5 (1.07) 3.5 (1.07) 3 (0.91)
EW52, EWP52 42396A-8 3.5 (1.07) 3.5 (1.07) 3 (0.91) 3 (0.91) 3 (0.91) 2.5 (0.76)
EW63, EWP63 42396A-7 3.5 (1.07) 3 (0.91) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2 (0.61)
EW64, EWP64 42396A-1 3.5 (1.07) 3 (0.91) 2.5 (0.76) 3 (0.91) 2.5 (0.76) 2 (0.61)
EW77, EWP77 42396A-11 3.5 (1.07) 3 (0.91) 2.5 (0.76) 3 (0.91) 2.5 (0.76) 2 (0.61)
EW85 42396A-5 3.5 (1.07) 3 (0.91) 2.5 (0.76) 3 (0.91) 2.5 (0.76) 2 (0.61)
EW90, EWP90 42396A-5 3.5 (1.07) 3 (0.91) 2.5 (0.76) 3 (0.91) 2.5 (0.76) 2 (0.61)
EW127A, EWP127A 42396A-9 3.5 (1.07) 3 (0.91) 2.5 (0.76) 3 (0.91) 2.5 (0.76) 2 (0.61)
EW132, EWP132 42396A-9 4 (1.22) 3 (0.91) 2.5 (0.76) 3 (0.91) 2.5 (0.76) 2 (0.61)
EW180, EWP180 43211A 4 (1.22) 3 (0.91) 2.5 (0.76) 3.5 (1.07) 2.5 (0.76) 2 (0.61)
EW220 43211A 4 (1.22) 3 (0.91) 2.5 (0.76) 3.5 (1.07) 2.5 (0.76) 2 (0.61)
EW240 43211A 4 (1.22) 3 (0.91) 2.5 (0.76) 3.5 (1.07) 2.5 (0.76) 2 (0.61)
Definitions and Assumptions
1. Per EIA-222 Standard:
Coefficient of drag for elliptical waveguide is 1.6 (average of 1.2 for cylindrical and 2.0 for flat members).
Ice forms completely around member (360 degrees).
Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occuring simultaneously.
2. Wind speeds are maximum, which includes gust factors and exposure factors.
Hanger Spacing
for HELIAX

Elliptical Waveguide
Recommended maximum hanger spacings are tabulated below for various
wind speed and ice conditions. The recommendations are based on
guidelines stated in EIA Standard RS-222 and new wind tunnel and
vibration tests. They supersede those in previous Andrew catalogs.
Installations in Typical Climates. Use the 125 mph (200 km/h), 1/2" ice
conditions, highlighted in red in the table.
Severe or Mild Climates. Use the wind speed and ice conditions that most
closely approximate the expected worst case conditions for the local climate.
44
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 44
45
AA-SL 243684 Angle Adaptor with 3/8" Tapped Holes
AA-SL-M10 243684-M Angle Adaptor with 10 mm Tapped Holes
AA-U SHA3 Universal Angle Adaptor
AA-US UA-3 Universal Angle Adaptor, Snap-in Version (Insert not included)
AK-45 42334 45 Degree Adaptor Kit
AT-K306-U UGBA-DINU-36 Arrestor Trapeze Kit
BA-114-1A 204679A-3 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for 1-1/4" corrugated coaxial cable
BA-114-1B 48939A-3 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for 1-1/4" corrugated coaxial cable
BA-12-1A 204679A-5 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for 1/2" corrugated coaxial cable
BA-12-1B 48939A-6 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for 1/2" corrugated coaxial cable
BA-12-2A NA 4" Boot Assembly
BA-12-2B NA 5" Boot Assembly
BA-12-3A 204679A-7 Boot Assembly Kit, 4" (101.6 mm) with 3 Holes for 1/2" corrugated coaxial cable
BA-12-3B 48939A-8 Boot Assembly Kit, 5" (127.0 mm) with 3 Holes for 1/2" corrugated coaxial cable
BA-12-4A NA 4" Boot Assembly
BA-12-5A NA 4" Boot Assembly
BA-12-5B NA 5" Boot Assembly
BA-127-1A WGB4-127 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for EW127 and WE130
BA-127-1B WGB5-127 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for EW127 and WE130
BA-12F-1A NA 4" diameter, One 1/2" flex, entry port boot assembly
BA-12F-1B NA 5" diameter, 1 LDF4, entry port boot assembly
BA-12F-2A NA 4" diameter, two 1/2" superflex, entry port boot assembly
BA-12F-2B NA 5" diameter, two hole for 1/2" superflex, entry port boot assembly
BA-12F-3A NA 4" diameter, three hole for 1/2" superflex, entry port boot assembly
BA-12F-3B NA 5" diameter, three hole for 1/2" superflex, entry port boot assembly
BA-12F-4A NA 4" diameter, four 1/2" superflex, entry port boot assembly
BA-12F-4B NA 5" Diameter, four 1/2" superflex, entry port boot assembly
BA-150-1A NA 4" Boot Assembly with 1 hole, EW150, EW132, and E150
BA-150-1A WGB4-132 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for WE150 and EW132
BA-150-1B WGB5-132 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for WE150 and EW132
BA-158-1A 204679A-4 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for 1-5/8" corrugated coaxial cable
BA-158-1B 48939A-4 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for 1-5/8" corrugated coaxial cable
BA-180-1A WGB4-180 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for EW180 and WE191
BA-180-1B WGB5-180 5" Boot Assembly with 1 hole, EW180
BA-214-1A 204679A-8 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for 2-1/4" corrugated coaxial cable
BA-214-1B 48939A-9 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for 2-1/4" corrugated coaxial cable
BA-220-1A WBG4-220 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for EW220
BA-220-1B WGB5-220 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for EW220
BA-37-1A WGB4-37 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for WE37
BA-37-1B WGB5-37 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for WE37
BA-400 NA 4" (101.6 mm) Boot Assembly, cushion not included
BA-46-1A NA 4" Boot Assembly with 1 hole, EW46
BA-46-1B NA 5" Boot Assembly with 1 hole, EW47
BA-500 NA 5" (127.0 mm) Boot Assembly, cushion not included
BA-52-1A WGB4-52 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for EW52 and WE61
BA-52-1B WGB5-52 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for EW52 and WE61
BA-58-1A 204679A-13 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for 5/8" corrugated coaxial cable
BA-58-1B 48939A-14 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for 5/8" corrugated coaxial cable
BA-58-2A NA 4" Boot Assembly
BA-58-2B NA 5" Boot Assembly
Appendix 7
Installation Accessories Part Number Cross Reference MTS to Andrew
MTS No. Andrew No. Description
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 45
46
BA-58-3A 204679A-14 Boot Assembly Kit, 4" (101.6 mm) with 3 Holes for 5/8" corrugated coaxial cable
BA-58-3B 48939A-15 Boot Assembly Kit, 5" (127.0 mm) with 3 Holes for 5/8" corrugated coaxial cable
BA-58-4B NA 5" Boot Assembly
BA-63-1A WGB4-63 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for EW63 and WE65
BA-63-1B WGB5-63 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for EW63 and WE65
BA-77-1A WGB4-77 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for EW77 and WE78
BA-77-1B WGB5-77 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for EW77 and WE78
BA-78-1A 204679A-2 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for 7/8" corrugated coaxial cable
BA-78-1B 48939A-1 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for 7/8" corrugated coaxial cable
BA-78-2A 204679A-18 Boot Assembly Kit, 4" (101.6 mm) with 2 Holes for 7/8" corrugated coaxial cable
BA-78-2B 204679A-18 5" Boot Assembly
BA-78-3A 204679A-15 Boot Assembly Kit, 4" (101.6 mm) with 3 Holes for 7/8" corrugated coaxial cable
BA-78-3B 48939A-2 Boot Assembly Kit, 5" (127.0 mm) with 3 Holes for 7/8" corrugated coaxial cable
BA-78-4A NA 4" Boot Assembly
BA-78-4B NA 5" Boot Assembly
BA-85-1A NA 4 " diameter, One hole for EW85 and WE108, entry port boot assembly
BA-85-1B NA 5 " diameter, One hole for EW85 and WE108, entry port boot assembly
BA-90-1A WGB4-90 Boot Assembly Kit, 4" (101.6 mm) with 1 Hole for EW90
BA-90-1B WGB5-90 Boot Assembly Kit, 5" (127.0 mm) with 1 Hole for EW90
BH-114-NH 42396A-1 Butterfly Hanger Kit for 1-1/4" corrugated and LMR-1700 coaxial cable
BH-127-NH 42396A-9 Butterfly Hanger Kit for EW127, EW132, WE130, and WE150
BH-12-NH 43211A Butterfly Hanger Kit for 1/2" corrugated, smooth wall, and LMR-600 coaxial cable
BH-158-NH 42396A-2 Butterfly Hanger Kit for 1-5/8" corrugated and smooth wall coaxial cable
BH-180-NH 43211A Butterfly Hanger Kit for EW180 and WE191
BH-214-NH 42396A-4 Butterfly Hanger Kit for 2-1/4" corrugated coaxial cable
BH-43-NH 42396A-16 Butterfly hanger for EW43
BH-52-NH 42396A-8 Butterfly hanger for EW52
BH-58-NH 42396A-9 Butterfly Hanger Kit for 5/8" corrugated and LMR-900 coaxial cable
BH-63-NH 42396A-1 Butterfly Hanger Kit for EW63 and WE65
BH-64-NH 42396A-1 Butterfly Hanger Kit for EW64
BH-77-NH 42396A-11 Butterfly hanger for EW77
BH-78-NH 42396A-5 Butterfly Hanger Kit for 7/8" corrugated, smooth wall, and LMR-1200 coaxial cable
BH-85-NH 42396A-5 Butterfly Hanger Kit for EW85, EW90, and WE108
BH-S114-NH 42396A-1 Standard Hanger for 1-1/4" corrugated coaxial cable
BH-S12-NH 43211A Standard Hanger for 1/2" corrugated and smooth wall coaxial cable
BH-S158-NH 42396A-2 Standard Hanger for 1-5/8" corrugated and smooth wall coaxial cable
BH-S214-NH NA Standard hanger for 2-1/4" cable
BH-S38-NH 43211A Standard Hanger for 3/8" corrugated and smooth wall coaxial cable
BH-S58-NH NA Standard hanger for 5/8" cable
BH-S78-NH 42396A-5 Standard Hanger for 7/8" corrugated and smooth wall coaxial cable
CB-114 L6CLICK Mini Coax Support Blocks for 1-1/4" corrugated coaxial cable
CB-114H L6SCLICK Hanger Clamps for 1-1/4" coaxial cable
CB-114L NA Large Coax Support Blocks 1-1/4"
CB-12 L4CLICK Mini Coax Support Blocks for 1/2" corrugated coaxial cable
CB-1200T NA Mini Coax Support Block for LMR-1200
CB-12CR NA Mini Coax Support Block for 1/2" smooth wall coaxial cable
CB-12H L4SCLICK Hanger Clamps for 1/2" coaxial cable
CB-12L NA Large Coax Support Blocks 1/2"
CB-158 L7CLICK Mini Coax Support Blocks for 1-5/8" corrugated coaxial cable
CB-158CR L7CLICK Mini Coax Support Blocks for 1-5/8" smooth wall coaxial cable
Installation Accessories Part Number Cross Reference MTS to Andrew
MTS No. Andrew No. Description
Appendix 7
appendixes
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 46
47
CB-158H L7SCLICK Hanger Clamps for 1-5/8" coaxial cable
CB-158L NA Large Coax Support Blocks 1-5/8"
CB-1700T NA Mini Coax Support Block for LMR-1700
CB-214L NA Large Coax Support Blocks 2-1/4"
CB-58 L45CLICK Mini Coax Support Blocks for 5/8" corrugated coaxial cable
CB-58H NA Hanger Clamps for 5/8" coaxial cable
CB-78 L5CLICK Mini Coax Support Blocks for 7/8" corrugated coaxial cable
CB-78CR NA Mini Coax Support Block for 7/8" smooth wall coaxial cable
CB-78H L5SCLICK Hanger Clamps for 7/8" coaxial cable
CB-78L NA Large Coax Support Blocks 7/8"
CH-114-NH 42396A-1 Clip Hanger Kit for 1-1/4" corrugated coaxial cable
CH-114-NH NA Clip Hanger for 1-1/4" corruagated cable
CH-12-NH 43211A Clip Hanger Kit for 1/2" corrugated and smooth wall coaxial cable
CH-12-NH NA Clip Hanger for 1/2" corruagated cable
CH-158-NH 42396A-2 Clip Hanger for Kit 1-5/8" corrugated and smooth wall coaxial cable
CH-158-NH NA Clip Hanger for 1-5/8" corruagated cable
CH-78-NH 42396A-5 Clip Hanger Kit for 7/8" corrugated and smooth wall coaxial cable
CH-78-NH NA Clip Hanger for 7/8" corruagated cable
CH-A114-1 NA Cushion Hanger Assembly with 1 Hole for 1-1/4" corrugated coaxial cable
CH-A12-1 NA Cushion Hanger Assembly with 1 Hole for 1/2" corrugated coaxial cable
CH-A12-2 NA Cushion Hanger Assembly with 2 Holes for 1/2" corrugated coaxial cable
CH-A12-3 NA Cushion Hanger Assembly with 3 Holes for 1/2" corrugated coaxial cable
CH-A12-4 NA Cushion Hanger Assembly with 4 Holes for 1/2" corrugated coaxial cable
CH-A12-5 NA Cushion Hanger Assembly with 5 Holes for SO Cord/Flashhead Cable
CH-A158-1 NA Cushion Hanger Assembly with 1 Hole for 1-5/8" corrugated coaxial cable
CH-A214-1 NA Cushion Hanger Assembly with 1 Hole for 2-1/4" corrugated coaxial cable
CH-A78-1 NA Cushion Hanger Assembly with 1 Hole for 7/8" corrugated coaxial cable
CH-A78-2 NA Cushion Hanger Assembly with 2 Holes for 7/8" corrugated coaxial cable
CH-A78-3 NA Cushion Hanger Assembly with 3 Holes for 7/8" corrugated coaxial cable
CH-A78-4 NA Cushion Hanger Assembly with 4 Holes for 7/8" corrugated coaxial cable
CP-114 PLUG-114 Cushion Plug for 1-1/4" corrugated coaxial cable
CP-12 PLUG-12 Cushion Plug for 1/2" corrugated coaxial cable
CP-158 PLUG-158 Cushion Plug for 1-5/8" corrugated coaxial cable
CP-38 NA Cushion Plug, 3/8" cable, kit of 5
CP-58 NA Cushion Plug, 5/8" cable, kit of 5
CP-78 PLUG-78 Cushion Plug for 7/8" corrugated coaxial cable
CS-A12 245174 Coldshrink weatherproofing kit 1/2" to 7/8" jumper to antenna
CS-A1F 245174 Coldshrink weatherproofing kit 1/2" to 7/8" jumper to antenna
CS-A58 245174 Coldshrink weatherproofing kit 1/2" to 7/8" jumper to antenna
CS-BS SHA3 Mini Cluster Support bracket
CS-U1212 245173 3M Cold Shrink, 1/2" to 1/2"
CS-U12158 245172 3M Cold Shrink
CS-U12214 245175 3M Cold Shrink, 1/2" to 2-1/4"
CS-U1278 245171 3M Cold Shrink, 1/2" to 7/8"
CS-U5858 241474-7 Coldshrink weatherproofing kit 5/8" to 5/8"
EP-1033 204673-9 Entry Panel, 9 port, 3 x 3
EP-1113 48940-9 Entry Panel, 9 port, 3 x 3
EP-1118 204673-12 Entry Panel, 12 port, 3 x 4, Standard
EP-1191 48940-8 Entry Panel, 8 port, 2 x 4
EP-1199 NA Entry Panel, 4 port, 2 x 2
Appendix 7
Installation Accessories Part Number Cross Reference MTS to Andrew
MTS No. Andrew No. Description
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 47
48
EP-1297 204673-10 Entry Panel, 10 port, 2 x 5
EP-1333 204673-18 Entry Panel, 18 port, 3 x 6
EP-1334 204673-12 Entry Panel, 12 port, 3 x 4, Large
EP-1336 204673-12A 4" Wall roof feed thru plate, twelve opening (2 X 6)
EP-1338 204673-8 Entry Panel, 8 port, 2 x 4, Large
EP-1340 204673-24 Entry Panel, 24 port, 4 x 6
EP-1447 204673-16 Entry Panel, 16 port, 4 x 4
EP-1448 204673-2A Entry Panel, 2 port, 1 x 2
EP-1449 204673-6 Entry Panel, 6 port, 2 x 3
EP-1635 204673-3 Entry Panel, 3 port, 1 x 3
EP-1861 204673-20 4" (101.6 mm) Entry Panel, 20 port, 4 x 5
EP-220 204673-1 Entry Panel, 1 port, 1 x 1, Standard
EP-549 48940-1 Entry Panel, 1 port, 1 x 1
EP-550 48940-2 Entry Panel, 2 port, 1 x 2
EP-551 48940-3 Entry Panel, 3 port, 1 x 3
EP-552 48940-4 Entry Panel, 4 port, 2 x 2
EP-553 48940-6 Entry Panel, 6 port, 2 x 3
EP-574 204673-2 Entry Panel, 1 port, 1 x 1, Compact
EP-575 204673-4 Entry Panel, 4 port, 1 x 4
EP-576 204673-8 Entry Panel, 8 port, 2 x 4, Standard
GB-0210-NH NA Ground Buss Bar, 1/4" x 2" x 10" (6.4 mm x 50.8 mm x 254.0 mm). Hardware not included.
GB-0210T-NH NA Tinned Ground Buss Bar, 1/4" x 2" x 10" (6.4 mm x 50.8 mm x 254.0 mm). Hardware not included.
GB-0210T-U UGBKIT-0210-T Tinned Ground Buss Bar Kit, 1/4" x 2" x 10" (6.4 mm x 50.8 mm x 254.0 mm)
GB-0210-U UGBKIT-0210 Ground Buss Bar Kit, 1/4" x 2" x 10" (6.4 mm x 50.8 mm x 254.0 mm)
GB-0212-NH NA Ground Buss Bar, 1/4" x 2" x 12". (6.4 mm x 50.8 mm x 304.8 mm). Hardware not included.
GB-0212T-NH NA Tinned Ground Buss Bar, 1/4" x 2" x 12". (6.4 mm x 50.8 mm x 304.8 mm). Hardware not included.
GB-0212T-U UGBKIT-0212-T Tinned Ground Buss Bar Kit, 1/4" x 2" x 12" (6.4 mm x 50.8 mm x 304.8 mm)
GB-0212-U UGBKIT-0212 Ground Buss Bar Kit, 1/4" x 2" x 12" (6.4 mm x 50.8 mm x 304.8 mm)
GB-0214-NH NA Ground Buss Bar, 1/4" x 2" x 14" (6.4 mm x 50.8 mm x 355.6 mm). Hardware not included.
GB-0214T-NH NA Tinned Ground Buss Bar, 1/4" x 2" x 14" (6.4 mm x 50.8 mm x 355.6 mm). Hardware not included.
GB-0214T-U UGBKIT-0214-T Tinned Ground Buss Bar Kit, 1/4" x 2" x 14" (6.4 mm x 50.8 mm x 355.6 mm)
GB-0214-U UGBKIT-0214 Ground Buss Bar Kit, 1/4" x 2" x 14" (6.4 mm x 50.8 mm x 355.6 mm)
GB-02512-NH NA Ground Buss Bar, 1/4" x 2-1/2" x 12-1/2" (6.4 mm x 63.5 mm x 317.5 mm). Hardware not included.
GB-02512T-NH NA Tinned Ground Buss Bar, 1/4" x 2-1/2" x 12-1/2" (6.4 mm x 63.5 mm x 317.5 mm). Hardware not included.
GB-02512T-U UGBKIT-2T Tinned Ground Buss Bar Kit, 1/4" x 2-1/2" x 12-1/2" (6.4 mm x 63.5 mm x 317.5 mm)
GB-02512-U UGBKIT-2 Universal Ground Bar 2.5" x 12.5"
GB-02519-NH NA Ground Buss Bar, 1/4" x 2-1/2" x 19-1/2" (6.4 mm x 63.5 mm x 495.3 mm). Hardware not included.
GB-02519T-NH NA Tinned Ground Buss Bar, 1/4" x 2-1/2" x 19-1/2" (6.4 mm x 63.5 mm x 495.3 mm). Hardware not included.
GB-02519T-U UGBKIT-T Tinned Ground Buss Bar Kit, 1/4" x 2-1/2" x 19-1/2" (6.4 mm x 63.5 mm x 495.3 mm)
GB-02519-U UGBKIT Universal Ground Bar 2.5" x 19.5"
GB-0412-NH NA Ground Buss Bar, 1/4" x 4" x 12" (6.3 mm x 101.6 mm x 304.8 mm). Hardware not included.
GB-0412T-NH NA Tinned Ground Buss Bar, 1/4" x 4" x 12" (6.3 mm x 101.6 mm x 304.8 mm). Hardware not included.
GB-0412T-U UGBKIT-0412-T Tinned Ground Buss Bar Kit, 1/4" x 4" x 12" (6.3 mm x 101.6 mm x 304.8 mm)
GB-0412-U UGBKIT-0412 Ground Buss Bar Kit, 1/4" x 4" x 12" (6.3 mm x 101.6 mm x 304.8 mm)
GB-0414-NH NA Ground Buss Bar, 1/4" x 4" x 14" (6.3 mm x 101.6 mm x 355.6 mm). Hardware not included.
GB-0414T-NH NA Tinned Ground Buss Bar, 1/4" x 4" x 14" (6.3 mm x 101.6 mm x 355.6 mm). Hardware not included.
GB-0414T-U UGBKIT-0414-T Tinned Ground Buss Bar Kit, 1/4" x 4" x 14" (6.3 mm x 101.6 mm x 355.6 mm)
GB-0414-U UGBKIT-0414 Ground Buss Bar Kit, 1/4" x 4" x 14" (6.3 mm x 101.6 mm x 355.6 mm)
GB-0420-NH NA Ground Buss Bar, 1/4" x 4" x 20" (6.3 mm x 101.6 mm x 508.0 mm). Hardware not included.
GB-0420T-NH NA Tinned Ground Buss Bar, 1/4" x 4" x 20" (6.3 mm x 101.6 mm x 508.0 mm). Hardware not included.
Appendix 7
appendixes
Installation Accessories Part Number Cross Reference MTS to Andrew
MTS No. Andrew No. Description
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 48
49
GB-0420T-U UGBKIT-0420-T Tinned Ground Buss Bar Kit, 1/4" x 4" x 20" (6.3 mm x 101.6 mm x 508.0 mm)
GB-0420-U UGBKIT-0420 Ground Buss Bar Kit, 1/4" x 4" x 20" (6.3 mm x 101.6 mm x 508.0 mm)
GB-0424-NH NA Ground Buss Bar, 1/4" x 4" x 24" (6.3 mm x 101.6 mm x 609.6 mm). Hardware not included.
GB-0424T-NH NA Tinned Ground Buss Bar, 1/4" x 4" x 24" (6.3 mm x 101.6 mm x 609.6 mm). Hardware not included.
GB-0424T-U UGBKIT-0424-T Tinned Ground Buss Bar Kit, 1/4" x 4" x 24" (6.3 mm x 101.6 mm x 609.6 mm)
GB-0424-U UGBKIT-0424 Ground Buss Bar Kit, 1/4" x 4" x 24" (6.3 mm x 101.6 mm x 609.6 mm)
GB-HK-U NA Universal Ground Bar Attachment Kit
GK-C114 SGL6-15B4 Clip-on Ground Kit for 1-1/4" corrugated coaxial cable
GK-C114-2H2 SGL6-06B2 Clip-on Ground Kit for 1-1/4" corrugated coaxial. Includes 2' (0.6 m) lead with attached 3/8" (9.5 mm) two-hole lug.
GK-C12 SGL4-15B4 Clip-on Ground Kit for 1/2" corrugated coaxial. Includes 5' (1.5 m) lead with unattached 3/8" (9.5 mm) two-hole lug.
GK-C12-2H2 SGL4-06B2 Clip-on Ground Kit for 1/2" corrugated coaxial. Includes 2' (0.6 m) lead with attached 3/8" (9.5 mm) two-hole lug.
GK-C158 SGL7-15B4 Clip-on Ground Kit for 1-5/8" corrugated coaxial cable
GK-C158-2H2 SGL7-06B2 Clip-on Ground Kit for 1-5/8" corrugated coaxial. Includes 2' (0.6 m) lead with attached 3/8" (9.5 mm) two-hole lug.
GK-C214 SGL12-15B4 Clip-on Ground Kit for 2-1/4" corrugated coaxial. Includes 5' (1.5 m) lead with unattached 3/8" (9.5 mm) two-hole lug
GK-C214-2H2 SGL12-06B2 Clip-on Ground Kit for 2-1/4" corrugated coaxial. Includes 2' (0.6 m) lead with attached 3/8" (9.5 mm) two-hole lug.
GK-C58 SGL45-15B4 Clip-on Ground Kit for 5/8" corrugated coaxial. Includes 5' (1.5 m) lead with unattached 3/8" (9.5 mm) two-hole lug.
GK-C58-2H2 SGL45-06B2 Clip-on Ground Kit for 5/8" corrugated coaxial. Includes 2' (0.6 m) lead with attached 3/8" (9.5 mm) two-hole lug.
GK-C78 SGL5-15B4 Clip-on Ground Kit for 7/8" corrugated coaxial cable
GK-C78-2H2 SGL5-06B2 Clip-on Ground Kit for 7/8" corrugated coaxial. Includes 2' (0.6 m) lead with attached 3/8" (9.5 mm) two-hole lug.
GK-S114 241088-60 Standard Ground Kit for 1-1/4" corrugated coaxial cable
GK-S12 241545 Standard Ground Kit for 1/2" corrugated coaxial cable
GK-S1200T 220497 Standard Ground Kit for LMR-1200 coaxial cable
GK-S127 220497 Standard Grounding Kit: EW127
GK-S12AC 241545 Standard Ground Kit for 1/2" smooth wall coaxial cable
GK-S132 220497 Standard Grounding Kit: EW132
GK-S158 220498 Standard Ground Kit for 1-5/8" corrugated coaxial cable
GK-S158AC NA Standard Grounding Kit: 1-5/8" cable, smooth wall
GK-S158CR 220498 Standard Ground Kit for 1-5/8" smooth wall coaxial cable
GK-S1700T 241088-60 Standard Ground Kit for LMR-1700 coaxial cable
GK-S180 241545 Standard Ground Kit for EW180 and WE191
GK-S214 223700-724 Standard Ground Kit for 2-1/4" corrugated coaxial cable
GK-S220 241545 Standard Ground Kit for EW220
GK-S37 223700-724 Standard Ground Kit for WE37
GK-S38 223158-4 Standard Ground Kit for 3/8" corrugated coaxial cable
GK-S43 220498 Standard Ground Kit for EW43
GK-S46 220498 Standard Ground Kit for WE46
GK-S52 220498 Standard Ground Kit for EW52 and WE61
GK-S58 220497 Standard Ground Kit for 5/8" corrugated coaxial cable
GK-S58AC 220497 Standard Ground Kit for 5/8" smooth wall coaxial cable
GK-S600T 241545 Standard Ground Kit for LMR-600 coaxial cable
GK-S63 220498 Standard Ground Kit for EW63 and WE65
GK-S64 241088-60 Standard Ground Kit for EW64
GK-S77 241088-60 Standard Ground Kit for EW77 and WE78
GK-S78 220497 Standard Ground Kit for 7/8" corrugated coaxial cable
GK-S78AC 220497 Standard Ground Kit for 7/8" smooth wall coaxial cable
GK-S78CR 220497 Standard Ground Kit for 7/8" smooth wall coaxial cable
GK-S85 220497 Standard Ground Kit for EW85, EW90, and WE108
GK-U2H5-U UG12158-15B4 Universal Ground Kit, 5' (1.5 m) lead with unattached 1/4" (6.4 mm) and 3/8" (9.5 mm) two-hole lugs
HG-114 29961 Lace-Up Hoisting Grip for 1-1/4" corrugated and LMR-1700 coaxial cable
HG-114L L6SGRIP Pre-Laced Hoisting Grip for 1-1/4" corrugated and LMR-1700 coaxial cable
Appendix 7
Installation Accessories Part Number Cross Reference MTS to Andrew
MTS No. Andrew No. Description
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 49
50
HG-12 43094 Lace-Up Hoisting Grip for 1/2" corrugated, smooth wall, and LMR-600 coaxial cable
HG-127 29958 Lace-Up Hoisting Grip for EW122, EW127, EW132, WE122, WE130, WE150
HG-12L L4SGRIP Pre-Laced Hoisting Grip for 1/2" corrugated, smooth wall, and LMR-600 coaxial cable
HG-158 24312A Lace-Up Hoisting Grip for 1-5/8" corrugated and smooth wall coaxial cable
HG-158L L7SGRIP Pre-Laced Hoisting Grip for 1-5/8" corrugated and smooth wall coaxial cable
HG-180 43094 Lace-Up Hoisting Grip for EW180, WE190, WE191
HG-214 31535 Lace-Up Hoisting Grip for 2-1/4" corrugated coaxial cable
HG-214L L12SGRIP Pre-Laced Hoisting Grip for 2-1/4" coaxial cable
HG-37 NA Lace up hoisting grip for EW37
HG-38L L2SGRIP Pre-Laced Hoisting Grip for 3/8" corrugated coaxial cable
HG-43 31535 Lace-Up Hoisting Grip for EW43 and WE46
HG-52 24312A Lace-Up Hoisting Grip for EW52 and WE61
HG-58 29958 Lace-Up Hoisting Grip for 5/8" corrugated, smooth wall, and LMR-900 coaxial cable
HG-58L L45SGRIP Pre-Laced Hoisting Grip for 5/8" corrugated, smooth wall, and LMR-900 coaxial cable Pre-Laced Hoisting Grip for 7/8"
HG-64 29961 Lace-Up Hoisting Grip for EW63, EW64, WE65, WE70
HG-77 29961 Lace-Up Hoisting Grip for EW77, WE78
HG-78 19256B Lace-Up Hoisting Grip for 7/8" corrugated, smooth wall, and LMR-1200 coaxial cable
HG-78L L5SGRIP Pre-Laced Hoisting Grip for 7/8" corrugated, smooth wall, and LMR-1200 coaxial cable
HG-85 19256B Lace-Up Hoisting Grip for EW85, WE90, WE108
HK-100-10 31769-1 Hanger Hardware Kit, 3/8" x 1" (9.5 mm x 25.4 mm) slotted hex head screws, lock washers, and hex nuts
HK-34-10 31769-5 Hanger Hardware Kit, 3/8" x 3/4" slotted hex head screws, lock washers and hex nuts
HK-DSCB 243095-5 3/8" Galvanized Hardware Kit for two Coax Support Blocks
HK-DSCB158 243095-8 3/8" Galvanized Hardware Kit for two 1-5/8" or LMR-1700 Coax Support Blocks
HK-DSCB158-M10 NA 10 mm Stainless Steel Hardware for 1-5/8" - 2
HK-DSCB-M10 NA 10 mm Stainless Steel Hardware - 2
HK-ECBL NA Extender SS Hardware kit for Support Blocks
HK-ECBL158 NA Extender SS Hardware kit for 1-5/8" Support Blocks
HK-ECBL214 NA Extender SS Hardware kit for 2-1/4" Support Blocks
HK-M1020-10 243684-MH Hanger Hardware Kit, 10 mm x 20 mm slotted head bolts, lock washers, and hex nuts
HK-SCBL NA SS Hardware kit for Support Blocks
HK-SCBL158 NA SS Hardware kit for 1-5/8" Support Blocks
HK-SCBL214 NA SS Hardware kit for 2-1/4" Support Blocks
HK-SSCB 243095-9 3/8" Galvanized Hardware Kit for one Coax Support Block
HK-SSCB158 243095-12 3/8" Galvanized Hardware Kit for one 1-5/8" or LMR-1700 Coax Support Block
HK-SSCB158-M10 NA 10 mm Stainless Steel Hardware for 1-5/8" - 1
HK-SSCB-M10 NA 10 mm Stainless Steel Hardware - 1
HK-TSCB 243095-4 3/8" Galvanized Hardware Kit for three Coax Support Blocks
HK-TSCB158 243095-12 3/8" Galvanized Hardware Kit for three 1-5/8" or LMR-1700 Coax Support Blocks
HK-TSCB158-M10 NA 10 mm Stainless Steel Hardware for 1-5/8" - 3
HK-TSCB-M10 NA 10 mm Stainless Steel Hardware - 3
MT-464 9905-41 3/4" Electrical tape
MT-465-1 9905-71 2" Electical tape
MT-469-2 42615-4 Butyl tape
MT-8806-66 9905-41 3/4" Electrical tape
RM-A100 31670-1 Round Member Adaptor, 1"-2" OD (25.4 mm-50.8 mm OD)
RM-A200 31670-2 Round Member Adaptor, 2"-3" OD (50.8 mm-76.2 mm OD)
RM-A300 31670-3 Round Member Adaptor, 3"-4" OD (76.2 mm-101.6 mm OD)
RM-A400 31670-4 Round Member Adaptor, 4"-5" OD (101.6 mm-127.0 mm OD)
RM-A500 31670-5 Round Member Adaptor, 5"-6" OD (127.0 mm-152.4 mm OD)
RM-A600 31670-6 Round Member Adaptor, 6"-8" OD (152.4 mm-203.2 mm OD)
Appendix 7
appendixes
Installation Accessories Part Number Cross Reference MTS to Andrew
MTS No. Andrew No. Description
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 50
51
SA-38S NA Standoff Adapter with 3/8" tapped hole
SA-38S02 NA Standoff Adapter with 3/8" tapped hole, for members 1-2" OD
SA-38S100 30848-5 Stand-off Adaptor for 1"-2" OD (25.4 mm-50.8 mm OD) members
SA-38S200 30848-4 Stand-off Adaptor for 2"-3" OD (50.8 mm-76.2 mm OD) members
SA-38S300 30848-1 Stand-off Adaptor for 3"-4" OD (76.2 mm-101.6 mm OD) members
SA-38S400 30848-2 Stand-off Adaptor for 4"-5" OD (101.6 mm-127.0 mm OD) members
SA-38S500 30848-3 Stand-off Adaptor for 5"-6" OD (127.0 mm-152.4 mm OD) members
SA-S100-M13 NA Standoff 10 mm tapped hole
SA-S125-M14 NA Standoff 10 mm tapped hole
SA-S25-M10 NA Standoff 10 mm tapped hole
SA-S50-M10 NA Standoff 10 mm tapped hole
SA-S75-M12 NA Standoff 10 mm tapped hole
SA-S-M10 NA Standoff Adapter with 10 mm tapped hole
SA-SS NA Snap-In Stand-off Adapter
SA-SS02 NA Snap-In Stand-off Adapter, for members 1-2" OD
SA-SS100 STS-12 Universal Stand-off Adaptor for 1"-2" OD (25.4 mm-50.8 mm OD) members
SA-SS200 STS-23 Universal Stand-off Adaptor for 2"-3" OD (50.8 mm-76.2 mm OD) members
SA-SS300 STS-34 Universal Stand-off Adaptor for 3"-4" OD (76.2 mm-101.6 mm OD) members
SA-SS400 STS-45 Universal Stand-off Adaptor for 4"-5" OD (101.6 mm-127.0 mm OD) members
SA-SS500 NA Snap in tower standoff adapter (5" - 6")
SAUH UAAI Universal angle adapter insert
SC-114-1 NA Standard Port Cushion with 1 Hole for 1-1/4" corrugated coaxial cable
SC-12-1 NA Standard Port Cushion with 1 Hole for 1/2" corrugated coaxial cable
SC-12-2 NA Standard Port Cushion with 2 Holes for 1/2" corrugated coaxial cable
SC-12-3 NA Standard Port Cushion with 3 Holes for 1/2" corrugated coaxial cable
SC-12-4 NA Standard Port Cushion with 4 Holes for 1/2" corrugated coaxial cable
SC-12-5 NA Standard Port Cushion with 5 Holes 3/8" corrugated coaxial cable
SC-158-1 NA Standard Port Cushion with 1 Hole for 1-5/8" corrugated coaxial cable
SC-214-1 NA Standard Port Cushion with 1 Hole for 2-1/4" corrugated coaxial cable
SC-38-1 NA Standard Port Cushion with 1 Hole for 3/8" corrugated coaxial cable
SC-38-3 NA Standard Port Cushion with 3 Holes for 3/8" corrugated coaxial cable
SC-38-9 NA Standard Port Cushion with 9 Holes for 3/8" corrugated coaxial cable
SC-58-1 NA Standard Port Cushion with 1 Hole for 5/8" corrugated coaxial cable
SC-58-2 NA Standard Port Cushion with 2 Holes for 5/8" corrugated coaxial cable
SC-58-3 NA Standard Port Cushion with 3 Holes for 5/8" corrugated coaxial cable
SC-58-4 NA Standard Port Cushion with 4 Holes for 5/8" corrugated coaxial cable
SC-78-1 NA Standard Port Cushion with 1 Hole for 7/8" corrugated coaxial cable
SC-78-2 NA Standard Port Cushion with 2 Holes for 7/8" corrugated coaxial cable
SC-78-3 NA Standard Port Cushion with 3 Holes for 7/8" corrugated coaxial cable
SC-78-4 NA Standard Port Cushion with 4 Holes for 7/8" corrugated coaxial cable
SC-B NA Standard Port Cushion, Blank (no holes)
SH-U114 SSH-114 Universal Snap-in Hanger for 1-1/4" corrugated and LMR-1700 coaxial cable
SH-U12 SSH-12 Universal Snap-in Hanger for 1/2" corrugated, smooth wall, and LMR-600 coaxial cable
SH-U158 SSH-158 Universal Snap-in Hanger for 1-5/8" corrugated and smooth wall coaxial cable
SH-U214 206706A-5 Universal Snap-in Hanger for 2-1/4" corrugated coaxial cable
SH-U58 206706A-6 Universal Snap-in Hanger for 5/8" corrugated, smooth wall, and LMR-900 coaxial cable
SH-U78 SSH-78 Universal Snap-in Hanger for 7/8" corrugated, smooth wall, and LMR-1200 coaxial cable
TR-SK12 31771 Threaded Rod Support Kit, 3/8" x 12" long
TR-SK12-5 31771-4 Threaded Rod Support Kit, 3/8" x 12" long
TR-SK24 31771-4 Threaded rod support kit, 24", kit of 2
Appendix 7
Installation Accessories Part Number Cross Reference MTS to Andrew
MTS No. Andrew No. Description
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 51
52
TR-SK24 31771-9 Threaded Rod Support Kit, 3/8" x 24" long
TR-SK24-5 31771-6 Threaded Rod Support Kit, 3/8" x 24" long
TR-SK300m10-5 NA 10 mm Thrd Rod Sprt Kit of 5(10 mm X 300 mm)
TR-SK36 NA Threaded rod support kit of 5 (36")
TR-SK36 NA Threaded rod support kit, 36", kit of 5
TR-SK36-5 31771-10 Threaded Rod Support Kit, 3/8" x 36" long
TR-SK600m10-6 NA 10 mm Thrd Rod Sprt Kit of 5(10 mm X 600 mm)
TR-SK900m10-7 NA 10 mm Thrd Rod Sprt Kit of 5(10 mm X 900 mm)
TW15 40417 Nylon Cable ties
TW15HD NA Nylon Cable ties
UGBKIT UGBKIT Universal Ground Bar: 2-1/2" x 19-1/2", with hardware
WK-U 221213 Universal Weatherproofing Kit
Appendix 7
Installation Accessories Part Number Cross Reference MTS to Andrew
MTS No. Andrew No. Description
CA-100351.1-EN NEW SIZE.qxd 10/17/05 3:18 PM Page 52
Worldwide Availability
ANDREW CORPORATION GLOBAL SALES
United States
Andrew Corporation
10500 W. 153rd Street
Orland Park, IL 60462 USA
Telephone: +1 (708) 349-3300
Fax: +1 (708) 349-5444
Australia
Andrew Australia
153 Barry Road
Campbellfield, Victoria
Australia 3061
Tel: +61 3 9300-7969
Fax: +61 3 9357-9110
Brazil
Andrew do Brasil Ltda.
Av. Com Camilo Julio 1256-CP 597
Zona Industrial
Sorocaba SP 18086-000 Brazil
Tel: +55 15 2102-4000
Fax: +55-15 2102-4001
Canada
Andrew Canada Inc.
606 Beech Street, West
Whitby, Ontario
Canada L1N 5S2
Tel: +1 (905) 668-3348
Fax: +1 (905) 668-8590
China
Andrew Telecom China Co. Ltd.
Beijing Branch
Units 10-12 on Level 17, Office Tower
E1,
The Towers, Oriental Plaza,
No. 1 East Chang An Avenue,
Dong Cheng District,
Beijing 100738, China
Tel: (+86-10) 8518-9608
Fax: (+86-10) 8518-9605
Andrew Telecom China Co. Ltd.
Chengdu Branch
Unit I, 8th Floor, First City Plaza
#308 Shuncheng Dajie
Chengdu 610017 China
Tel: (+86-28) 6527905
Fax:(+86-28) 6527906
Andrew Telecom China Co. Ltd.
Guangzhou Branch
Rm. 4606, Metro Plaza No. 183
Tian He Bei Lu, Tian He Qu,
Guangzhou 510620 China
Tel: (+86-20) 8755-7063/7050
Fax: (+86-20) 8755-7065
Andrew Hong Kong Ltd.
2006 ING Tower
308-320 Des Voeux Road Central
Hong Kong
Tel: +852 2515-7500
Fax: +852 2515-7599
Andrew Telecom China Co. Ltd.
1st floor, Xing Yuan Building
No. 410, Gui Ping Rd.
Cao He Jing Development Zone
Shanghai, 200233 China
Tel: (+86-21) 5464-4688
Fax: (+86-21) 5426-3220
Finland
Andrew Communication Oy
Kiilakiventie 1
FIN-90250
Oulu, Finland
Tel: +358 40-55-99-009
Fax: +358 8-5210-109
France
Andrew S.A.R.L.
28, rue Fresnel,
Z. A. Pariwest
BP 182
Coignires Cedex 78313
France
Tel: +33 1 30-05-45-50
Fax: +33 1 34-61-76-55
Germany
Andrew GmbH
Freischtzstrasse 96
81927 Munich, Germany
Tel: +49 89 99-271-100
Fax: +49 89 99-271-120
Andrew GmbH
Zur Halbinsel 3
45356 Essen, Germany
Tel: +49 201 836-0710
Fax: +49 201 836-0720
India
Andrew Telecommunications India
Private Ltd.
#D-64, Defence Colony
New Delhi 110 024 India
Tel: +91 11 2-465-4562
Fax: +91 11 2-465-4565
Andrew Telecommunications India
Private Ltd.
Plot #76, Pilerne Industrial Estate
Bardez, Goa 403511 India
Tel: +91 0 832 2407312
Fax: +91 0 832 2407314
Indonesia
Andrew Jakarta Office
Benchmartk,
The Ascott Jakarta
2 Jalan Kebon Kacang Raya
Jakarta 10230 Indonesia
Tel: +62 21 318-5821
Fax: +62 21 318-5820
Italy
Andrew SRL
Via Vittor Pisani 14
20124 Milano MI, Italy
Tel: +39 02 677-1601
Fax: +39 02 667-15262
Business Centre Parco de' Medici
Viale Castello della Magliana 38
00148 Roma, Italy
Tel. +39 06 65970277
Tel. +39 06 65970278
Fax +39 06 65970233
Japan
Andrew International Corporation
Room 305-Nagatacho TBR Bldg.
2-10-2 Nagata-cho
Chiyoda-Ku, Tokyo, Japan 100
Tel: +81 3 3581-0221
Fax: +81 3 3581-0222
Malaysia
Andrew Corporation
Level 12-03B, Plaza Masalam
2 Jalan Tengku Zabedah Ampuan
E9/E - 40100 Shah Alam
Selangor Darul Ehsan, Malaysia
Tel: +60 3 5512-6370
Fax: +60 3 5512-7324
Mexico
Andrew Corporation Mxico, SA de CV
Monte Elbruz 124 - 402A
Col. Palmitas Polanco
Mxico, D.F. 11560
Tel: +52 55 1346-1900
Fax: +52 55 1346-1901
New Zealand
Andrew New Zealand Inc.
PO Box 50-691, Porirua
Wellington 6215 New Zealand
Tel: +64 4 238-0700
Fax: +64 4 238-0701
Philippines
Andrew Philippines Inc.
Unit 907, 9th Floor
Antel 2000 Corporate Centre Building
121 Valero Street, Salcedo Village
Makati City, Manila, Philippines
Tel: +63 2 751-5170/ 887-1086
Fax: +63 2 751-5171
Russia
Andrew International Corporation
Gubkina STR 8
Moscow 117966 Russia
Tel: +7 095 748-0001
Fax: +7 095 748-0002
Saudi Arabia
Andrew Corporation
1st Floor, Al Khozama Center.
P.O. Box 53215, Riyadh 11583
Kingdom of Saudi Arabia
Tel: +966 1 465-4650 ex. 7412/7414
Fax: +966 1 465-4650 ex. 7413
Singapore
Andrew International Corporation
Singapore Representative Office
391A Orchard Road #12-01
Ngee Ann City Tower A
Singapore 238873
Tel: +65 683-85246
Fax: +65 673-89428
South Africa
Andrew Satcom Africa (Pty) Ltd.
PO Box 786117
Sandton 2146
Republic of South Africa
Tel: +27 11 719-6000
Fax: +27 11 444 5393
Spain
Andrew Espaa SA
Paseo de la Castellana, 140, 4B
28046 Madrid, Spain
Tel: +34 917 45-20-40
Fax: +34 915 64-29-85
Sweden
Andrew AB
Djursholmsvgen 30
SE-183 52 Tby, Sweden
Tel: +46 8 544-708-90
Fax: +46 8 768-37-70
Switzerland
Andrew Kommunikations Systeme AG
Bchliwis 2B - 8184 Bachenblach
Zurich, Switzerland
Tel: +41 1 863-73-73
Fax: +41 1 863-73-80
Thailand
Andrew International Holding Corporation
9 Soi Yasoob 2
Vibhavadee-Rangsit Road,
6th Floor (B) Vorasin Building,
Lardyao, Chatuchak,
Bangkok 10900, Thailand
Tel. +66 2 691-5923, 691-5925
Fax. +66 2 691-5924
United Kingdom
Andrew Ltd.
Ilex Building Mulberry Business Park
Fishponds Road Wokingham
Berkshire RG41 2GY, England
Tel: +44 118 936-6700
Fax: +44 118 936-6777
Customer Support Center
Call toll-free from
North America:
Tel: 1-800-255-1479
Fax: 1-800-349-5444
International:
Tel: +1-708-873-2307
Fax: +1-708-349-5444
United Kingdom: 0800-250055
Australia: 1800-803 219
Brazil: 0800-704-4175
New Zealand: 0800-441-747
Internet
www.andrew.com
One Company. A World of Solutions.
All designs, specifications and availabilities of products and services presented in this catalog are subject to change without notice.
CA-100351.1-EN (10/05) 2005 Andrew Corporation, Orland Park, IL 60462 USA