Sei sulla pagina 1di 17

UNIT TOTAL

PRICE PRICE
1420-01 Surface finishing of flat or sloped installation areas, SQM P.M.
Surface finishing of flat or sloped installation areas, also in
presence of obstacles or restrictions (foundations, sleepers,
pipe systems, etc.) by hand or mechanically, including
the disposal of waste material.
1420-02
Surface compaction of areas as per ' 1420-01, including
soil wetting to obtain a compaction index not lower than
90%
SQM P.M.
Surface compaction of areas as per item 1420-01, including
soil wetting to obtain a compaction index not lower than
90% Modified according to Indian Code density.
1420-03
Surface compaction of areas, including soil wetting to
obtain a compaction index not lower than 95%
SQM P.M.
As per item 1420-02 but with a compaction index of 95% of
the Modified according to INDIAN Code density.
1420-04
Ground surface finishing medium size crushed stone (2-
3cm) with final depth of 5cm
SQM 121
Ground surface finishing with medium-size crushed stone (2-
3cm), also in presence of obstacles, both in flat or sloped
area, final layer depth 5 cm (soft finish).
1420-05
Ground surface finishing medium size crushed stone with
final depth of 10 cm
SQM P.M.
As per item 1420-04, but with final depth of 10 cm (soft
finish)
1420-05A
Ground surface finishing medium size crushed stone with
final depth greater than 10 cm
SQM P.M.
As per item 1420-04, but with final depth greater than 10
cm.
1440-05 General excavation In loose or compacted soil, or backfill. CBM 54,450
General excavation in any kind of soil at any depth below
ground level, the ground water being at max. height of 20
cm above bottom of excavation, including material loading,
and
1440-06 General excavation In soft rock. CBM P.M.
General excavation in any kind of soil at any depth below
ground level, the ground water being at max. height of 20
cm above bottom of excavation, including material loading,
and
1440-07 General excavation In solid rock with demolishing tools. CBM P.M.
General excavation in any kind of soil at any depth below
ground level, the ground water being at max. height of 20
cm above bottom of excavation, including material loading,
and
1440-08 General excavation In solid rock by blasting. CBM P.M.
General excavation in any kind of soil at any depth below
ground level, the ground water being at max. height of 20
cm above bottom of excavation, including material loading,
and
1440-09
Extra-price for presence of ground water table (over 20 cm
height from bottom of excavation).
CBM 50,380
to cover all works such as de-watering, collecting,
discharge, etc. included the supply of all consumables.
Section excavation means any trench excavation with
reduced width for foundations, ditches, pipe systems,
electrical and/or instrument cable trenches, etc. Generally,
trenches for sewer piping, electrical and/or instrument cable
systems, inspection pits, conduits and similar, are classified
as foundation excavations with position and dimensions as
shown on the drawings or specifications.
1440-10 Section excavation By hand in earth, up to 2 m. deep. CBM 94
Section excavation in any kind of soil at any level as per
drawings, the ground water being at max. height of 20 cm
above the bottom of excavation, including material loading
and transport to site dump, discharge and ground leveling.
1440-11
Section excavation By hand in earth from 2 m. up to 4 m.
deep.
CBM 99
ITEMS U.M. Q.TY PRICE LIST DESCRIPTION
Section excavation in any kind of soil at any level as per
drawings, the ground water being at max. height of 20 cm
above the bottom of excavation, including material loading
and transport to site dump, discharge and ground leveling.
1440-12 Section excavation By hand in earth over 4 m. deep. CBM 11
Section excavation in any kind of soil at any level as per
drawings, the ground water being at max. height of 20 cm
above the bottom of excavation, including material loading
and transport to site dump, discharge and ground leveling.
1440-20
Extra-price on 1440-10 to 1440-12 for presence of ground
water table
CBM P.M.
Extra-price on 1440-10 to 1440-12 for presence of ground
water table (over 20 cm height from bottom of excavation)
to cover all works such as de-watering, collecting,
discharge,
Section excavation means any trench excavation with
reduced width for foundations, ditches, pipe systems,
electrical and/or instrument cable trenches, etc. Generally,
trenches for sewer piping, electrical and/or instrument cable
systems,
inspection pits, conduits and similar, are classified as
foundation excavations with position and dimensions as
shown on the drawings or specifications.
1440-30 Section excavation Mechanically in earth up to 2 m. deep. CBM 1,870
1440-31
Section excavation Mechanically in earth from 2 up to 4 m
deep.
CBM 1,980
1440-32 Section excavation Mechanically in earth over 4 m deep. CBM 220
1440-40
Extra-price on 1440-30 to 1440-32 for presence of ground
water table
CBM P.M.
Extra-price on 1440-30 to 1440-32 for presence of ground
water table (over 20 cm height from bottom of excavation)
to cover all works such as de-watering, collecting,
discharge,
etc. included the supply of all consumables.
1440-44
Transport of Excavated materials from general and/or
section excavations
CBM 29,700
Transport only of excavated material to the dumping area
approved by the proper Authorities and/or Contractor,
outside the site, at a distance of 20 Km max. including any
payment or rent for using the dump. Unloading is included
in the relevant transport
1440-46
Extra-price per Km for transporting the said materials more
than 20 Km distant.
CBM P.M.
Transport only of excavated material to the dumping area
approved by the proper Authorities and/or Contractor,
outside the site, at a distance of 20 Km max. including any
payment or rent for using the dump. Unloading is included
in the relevant transport
1440-50 Back-filling using excavation materials CBM 24,750
The back-filling material shall be placed and compacted
evenly around the structures in layers not exceeding 300
mm thickness (loose material) and it shall be compacted up
to 95% of maximum dry density using excavation materials
and/or supplied by the Sub-Contractor according to the
groups. The fill material shall be conditioned with water to
within two per cent (2%) of the optimum moisture
content. The compaction shall be performed with suitable
rollers: heavy pneumatic tired roller compactor or
heavy vibrating compactor.
1440-51 Back-filling using materials supplied by sub-Contractor CBM 9,900
1440-52
Supply and laying of quarry or river sand, for sub-bases,
side filling and/or covering
CBM 708
Supply and laying of quarry or river sand, for sub-bases,
side filling and/or covering of piping systems and filling of
hollow foundations
1440-53
Sand supply and laying for the bedding and covering of
electrical cables directly buried
CBM P.M.
Sand supply and laying as per item 1440-52 above, but for
the bedding and covering of electrical cables directly buried
Any embankment for construction areas in compacted
layers, (max, thickness: 25 cm (loose material) or as
specified in the Technical Specifications and/or
Construction Specifications, with or without obstacles such
as foundations, masonry works, piping, etc., using
excavation and/or ground works material, or supplied by
Sub-Contractor, according to the groups indicated in the
"SOIL CLASSIFICATION" and as specified in the
"Technical Specifications".
1440-60
General embankments for plant areas using excavation
materials
CBM P.M.
1440-61
General embankment by means of materials supplied by
Contractor.
CBM P.M.
1440-71A
Tank pad construction all-Inclusion, with concrete ring wall
having a section up to 0,60
SQM P.M.
Tank pad construction all-Inclusion, with concrete ring wall
having a section up to 0.60m2. Including execution of
foundation for tanks constituted of concrete ring wall,
excavation, backfilling, transport of surplus material to dump
area, filling inside concrete ring wall using material defined
in Soil Classification, spread in layers 25 cm thk. Max
(loose material) compacted up to 95% of MDD (modified
Proctor test), lean concrete thickness 5 cm, concrete with
specified compressive strength (fc) of 30 N/mm2,
formworks,
reinforcement (100 kg/m3 with 5%) of concrete,
bituminous emulsion on top of pad (1kg/ m2), 3 cm. of
asphalt wearing course, bituminous mastic for sealing to
install after hydraulic test on the circumference of shell
bottom and whatever necessary to have the work complete.
Asphalt impregnated board shall be supplied and installed
in accordance with API-650.
1440-71B
Tank pad construction all-Inclusion, with concrete ring wall
having a section from 0.61 m2 to 0.90 m2
SQM 77
1440-71D
Deduction and/or increasing of price for item 1440-71AB
for weight reinforcement variation.
KG P.M.
Deduction and/or increasing of price for item 1440-71AB
for weight reinforcement variation. Variation within 5% in
weight of reinforcement stated in item 1440-71A/B shall not
be ground for claim. Only variation quantities exceeding
5% the specified ratio shall be accounted in addition or in
deduction.
1440-74
Supply and installation of tank foundation surface with a
layer of gravel, 10 20 mm size,
SQM P.M.
closed with 5 mm aggregates and bituminous emulsion (1
kg/m2) or in accordance with Standards. Total thickness
100 mm. Including placing the material in place near the
working area, loadings, transports, unloading and any fee.
1440-75
Supply, laying and rolled of a layer of sand/cement mixture,
10 20 cm thick, on top of Tank pad.
CBM P.M.
The sand must be toughly mixed with cement type 1 in the
10:1 weight ratio. Including placing the material in place
near the working area, loadings, transports, unloading,
spreading and any fee.
1440-76
Coating of storage tank foundations with bituminous
conglomerate, final thickness 3 cm,
SQM P.M.
to be rolled and set according to the slopes specified on the
project drawings. Including placing the material in place
near the working area, loadings, transports, unloading and
any fee.
1471-01 Iinstallation of carbon steel pipes and fittings KG 14,492
Assembling and installation of carbon steel pipes and
fittings, externally coated as specified in Technical
Specification and/or in Construction Specification with
bituminous
product and reinforced by fiberglass mesh weighing 900 g
/m2. The system will be laid on pipe bed if any, (as per
project drawings). Including bends, T pieces, pipe cuts,
bevelling
welding, connections and any necessary accessories and/or
activities to complete the works. Excluding only excavation,
transport, sand pipe bed and backfilling. To be accounted
per kg of uncoated steel piping on the overall layout length
1471-02 Installation of carbon-steel valves KG 883
Assembly and installation of carbon-steel valves. Including
coating material.
1471-05 Installation of carbon steel flanges KG 277
Assembly and installation of carbon steel flanges.
1472-01 Supply, assembly and installation of stainless steel pipe LM 206
Supply, assembling and installation of Stainless steel pipes
and fittings, externally coated as specified in Technical
Specification and/or in Construction Specification. The
system will be laid on pipe bed if any, (as per project
drawings). Including bends, T pieces, pipe cuts,
connections and any necessary accessories and/or
activities to complete the works. Excluding only excavation,
transport, sand pipe bed and backfilling. To be accounted
per lm of uncoated steel piping on the overall layout length
measured on the centreline and on project drawings.
1490-18
Mechanical hole drilling (max. diameter 75 mm) on
reinforced concrete constructions
LM P.M.
1490-20
Drilled holes for dia 30 mm (min) to 50 mm (max) with
length 300 mm on reinforced concrete.
LM P.M.
Execution of holes in existing concrete works with drilling
machine. The price include fill with Epoxy Resin.
1491-02
Clay lining 20cm tck bottom tank basins (impervious) Under
tank Leak protection
SQM 62
as per Engineering specification Under tank Leak
protection. Item includes: selected material requirement,
loading on trucks and transportation inside the plant,
unloading, spreading and compaction as per Engineering
Specification.
1491-03 Wearing course, 5 cm. thick SQM 62
after rolling, spread on binder, obtained by hot blending 6%
solid bitumen and 94% of broken stone and grit, including
all necessary material,transport, spreading with suitable
vibrating equipment, rolling with 8 tons. roller min. and
whatever else is required to complete the works.
1491-04 Supply and erection Geotextile sheet. SQM 3,300
1491-05
Lining pad beneath tank with waterproof membrane Under
tank Leak protection
SQM P.M.
as per Engineering Specification Under tank Leak
protection.
Item includes : selected material requirement, loading on
trucks and transportation inside the plant, installation as per
Engineering Specification.
1491-06 Lining pad beneath tank with HDPE membrane liner. SQM 85
As per item 1491-05 but HDPE membrane liner.
1491-07
Sand bed layer (5+5 cm) 10cm tck for waterproof
membrane
SQM P.M.
item 1491-05 as per Engineering Specification; Under tank
Leak protection. Item includes : selected material
requirement, loading on trucks and transportation inside the
plant, unloading, spreading and compaction as per
Engineering Specification.
1491-08 Perforated PVC drain and test sleeve 50mm LM P.M.
Perforated PVC drain and test sleeve 50mm as per
Engineering Specification Under tank Leak protection.
Item includes : selected material requirement, transportation
inside the plant, unloading and installation as per
Engineering Specification.
1710-02 Supply, bending and installation of deformed bars KG 3,293,571
as indicated in Technical Specifications and/or Construction
Specifications.
1710-03
Supply and installation of electrical welded mesh
reinforcement
KG P.M.
Supply and installation, in accordance with construction
drawings, of electrically-welded mesh reinforcement as
indicated in Technical Specifications and/or Construction
Specifications.
1710-07 Supply and installation of anchor bolts of up to 20 kg KG 49,418
as indicated in the project drawings and/or in Technical
Specifications and/or Construction Specifications.
1710-08 Supply and installation of anchor bolts over 20.01 kg KG 70,199
1710-11
Supply and installation of sliding plates for horizontal
equipment
KG 394
as indicated in project drawings and/or in Technical
Specifications and/or Construction Specifications.
1710-12 Installation only of sliding plates for horizontal equipment KG P.M.
as per item 1710-11.
1710-13 Supply and installation of neoprene or teflon plates or block KG P.M.
as described in Technical Specifications and/or
Construction Specifications.
1710-15
Supply and installation of metal components in galvanized
or non galvanized steel
KG 105,490
such as plates, angles, etc. as specified in project drawings
and/or in Technical Specifications
and/or Construction Specifications.
1710-15M
Supply and installation of stainless steel plate AISI 316 with
various thickness from 5mm to 15 mm.
KG 376
as specified in project drawings and/or in Technical
Specifications and/or Construction Specifications.
1710-17 Supply and installation of expansion bolts of up to 10 kg U 279
as indicated in the project drawings and/or in Technical
Specifications and/or Construction Specifications.
1710-18
Supply and installation of expansion bolts of from 10 kg to
20kg
U 110
as indicated in the project drawings and/or in Technical
Specifications and/or Construction Specifications.
1710-19 Supply and installation of chemical bolts of up to 10 kg, U 55
as indicated in the project drawings and/or in Technical
Specifications and/or Construction Specifications.
1710-20
Supply and installation of chemical bolts of from 10kg to
20kg
U 110
as indicated in the project drawings and/or in Technical
Specifications and/or Construction Specifications.
1799-01
Supply and installation of expansion bolts type Hilti or
equivalent with diameter from 12mm to 16 mm
U P.M.
including all equipment and activities to perform installation
according to Vendor instructions. Chipping of concrete
surface to discover the bars before hole execution shall be
included.
1799-02
Supply and installation of expansion bolts type Hilti or
equivalent with diameter from 20 mm to 24 mm
U P.M.
including all equipment and activities to perform installation
according to Vendor instructions. Chipping of concrete
surface to discover the bars before hole execution shall be
included.
1710-21
Supply and laying of normal leveling mortar (grout), 25 mm
thk
SQM P.M.
made in accordance with the above requirements and
requirements of Technical Specifications and/or drawings,
for
grouting of plates, base frames or other anchoring elements
for structures and/or machines, including cleaning of
surfaces, necessary formworks, chamfering of edges,
smoothing of exposed surfaces and all other operations and
charges necessary to complete the work in accordance with
Contract Specifications.
1710-22
Supply and laying of normal leveling mortar (grout) 50 mm
thk
SQM P.M.
As per item 1710-21 except that thickness shall be 50 mm.
1710-24
Supply and laying of special leveling mortar, "non-shrinking
grout", 25 mm thk
SQM 503
made with special factory-mixed components with size and
grading and chemical mechanical
properties in accordance with requirements stated above
and in the Technical Specifications, or as approved by the
Contractor, for grouting of plates, base frames or other
anchoring elements of structures and/or machines,
including all duties and charges stated in item 1710-21.
1710-25
Supply and laying of special leveling mortar, "non-shrinking
grout" 50 mm.
SQM 263
As per previous item 1710-24 except that thickness shall be
50 mm.
1710-26
Supply and laying of special leveling mortar, "non-shrinking
grout" greater than 50 mm
CBM P.M.
As per previous item 1710-24 except that thickness shall be
greater than 50 mm. or for filling of pockets and similar.
1710-27 Supply and laying of epoxy grout thickness 25 mm SQM 223
with requirements stated in the Technical Specifications or
as approved by the Contractor, for grouting of vibrating
machines, including all duties and charges stated in item
1710-21.
1710-28 Supply and laying of epoxy grout thickness 50 mm. SQM 43
As per previous item 1710-27 except that thickness shall be
50 mm.
1710-29
Supply and laying of epoxy grout thickness greater than 50
mm
CBM P.M.
As per previous item 1710-28 except that thickness shall be
greater than 50 mm or for filling of pockets and similar.
1710-30
Non-shrinking grout 25mm Chockfast Red Epoxy type sand
filled
SQM 32
or similar qualified Indian material. Grout shall be placed in
a manner that does not interfere with the movement of
equipment or structure designed for expansion. Grout shall
be mixed, placed, and cured in accordance with
manufacturer's recommendations. Levelling by screws,
wedges, and shims.
For Sub-Contractor's duties and accounting refer to item
1710-24.
1710-31 Non-shrinking grout 50mm Resin Epoxy type sand filled SQM 204
As per item 1710-30 but thickness 50 mm.
1710-32 Non-shrinking grout > 50mm Resin Epoxy type sand filled CBM 12
As per item 1710-30 but > 50mm thickness.
1711-01 Supply and laying of lean concrete layer, 5 cm thick SQM 3,215
1711-02 Supply and laying of lean concrete layer, 10 cm. Thick SQM 8,150
1711-03
Supply and laying of lean concrete, layer over 10 cm thick (
CC 1:3:6)
CBM 257
1711-06 Supply and casting of foundation concrete ( M30 ) CBM 19,029
(fc not less than as specified in Technical Specifications
and/or Construction Specifications).
1711-07
Surface treatment of foundation in contact with aggressive
water by means of bituminous paint
SQM 16,799
Surface treatment of foundation in contact with aggressive
water by means of bituminous paint, as indicated in
Technical Specifications or drawings.
1711-08
Supply and casting of fc = 30 N/mm2 concrete for sleepers,
all inclusive
LM P.M.
as indicated in the Technical Specifications, including:
excavation, removal of the excavated material, back-filling,
formworks, reinforcement rods, metal inserts, lean concrete
and whatever else may be required to complete the works.
1711-09
Supply and casting of fc = 30 N/mm2 concrete for vertical
ladder foundations
U 33
as indicated in Engineer standard dwg, including:
floor scraping, when necessary, form-works, reinforcement
rods, anchor bolts (when not supplied by Contractor),
excavation and backfilling if necessary, and whatever else
may be required to complete the works.
1711-10
Supply and casting of fc = 30 N/mm2 concrete for stair
foundations
U 17
Supply and casting of fc = 30 N/mm2 concrete for stair
foundations as indicated in Engineer standard dwg,
including:
floor scraping, when necessary, form-works, reinforcement
rods, anchor bolts (when not supplied by Contractor),
excavation and backfilling if necessary, and whatever else
may be required to complete the works.
1711-11
Supply and casting of fc = 30 N/mm2 concrete for small
dimension foundations (0.20 cubic meter max),
U 77
Supply and casting of fc = 30 N/mm2 concrete for small
dimension foundations (0.20 cubic meter max), such as
auxiliary piping supports, stub-ups, drain protection,
including
floor scraping, form-works and whatever else may be
required to complete the works.
1711-12 Hydrants basements U 11
Hydrants basements. According to engineering drawing.
Price shall be all included.
1711-13 Lance monitor basements U 6
Lance monitor basements. According to engineering
drawing.
Price shall be all included.
1711-20 Supply and assembling of timber or steel formworks SQM 15,100
Supply and assembling of timber or steel formworks,
complete with any necessary accessories and supports,
including the removal within the scheduled dates for
foundation works as per item 1711-06.
1711-21 Supply and assembling of circular formwork SQM 155
Supply and assembling of circular formwork as described in
1711-20 for foundation concrete.
1712-01
Supply and casting of elevation concrete at a max height of
10.00 m
CBM 4,012
Supply and casting of elevation concrete with fc of not less
than that specified in the Technical Specifications, for:
- columns;
- beams, lintel and masonry reinforcing girders;
- stairs;
- roofing slabs;
- machinery basements on slabs;
- bridges and box culverts;
at a max height of 10.00 m measured from the upper face
of the plinth or foundation mat.
1712-02
Supply and casting of elevation concrete at a height from
10.01 up to 20.00 m.
CBM 1,029
Supply and casting of elevation concrete as per item 1712-
01, but at a height from 10.01 up to 20.00 m. measured as
per item 1712-01 above.
1712-03
Supply and casting of elevation concrete at a height of more
than 20.01 m.
CBM 473
Supply and casting of elevation concrete, as per item 1712-
01, but at a height of more than 20.01 m. measured as per
item 1712-01.
1712-20
Supply and assembling of elevation timber or steel
formworks up to 10 mt
SQM 13,378
Supply and assembling of timber or steel formworks,
complete with any necessary accessories and supports,
including the removal within the scheduled dates for
elevationworks as per item 1712-01.
1712-21
Supply and assembling of elevation formwork from 10.01 up
to 20.00 m
SQM 1,349
Supply and assembling of formworks as described in 1712-
20 for concrete works as per item 1712-02.
1712-22
Supply and assembling of elevation formworks more than
20.01 m.
SQM 871
Supply and assembling of formworks as described in 1712-
20 for concrete works as per item 1712-03.
1712-23
Supply and assembling of elevation circular formworks up to
10.00 mt high
SQM 1,038
Supply and assembling of circular formworks as described
in 1712-20 for elevation concrete up to 10.00 mt high.
1713-01
Supply and laying of sub-base for r.c. road and paving in
compacted layers max. thk 25 cm
CBM P.M.
Supply and laying of sub-base for reinforced concrete
paving and road in compacted layers (max. thickness 25
cm) or as indicated in Technical Specifications and sloped
according to the project drawings or specifications. Material
shall be indicated in the "SOIL CLASSIFICATION" table.
The degree of soil compaction and the required CBR value
shall be according to Technical Specifications and/or
Construction Specifications.
1713-03
Supply and installation of a vapour barrier, consisting of a
polyethylene sheet
SQM P.M.
Supply and installation of a vapour barrier, consisting of a
polyethylene sheet with a thickness as indicated on the
construction drawings and/or in Technical Specifications.
1713-04 Concrete Road and Paving 10 cm thk SQM P.M.
Paving and road slab in reinforced concrete, fc as per
Technical Specifications, cast in sections, including
vibration, finishing with the required slopes and formworks
and
excluding only the reinforcement bars, calculated as per the
corresponding Price List item: slab thickness 10 cm.
1713-04A
Reinforced concrete road andpaving thickness 10 cm class
30 N/mm2, all inclusive
SQM P.M.
Reinforced concrete paving and road thickness 10 cm class
fck 30 N/mm2 including excavation for paving encasement
(if necessary), subgrade compaction as specified in
Technical Specifications, sub-base 20 cm thickness using
excavation materials as per "SOIL CLASSIFICATION" laid
in layers not higher than 25 cm (loose material) and
compacted up to 95% MDD, polyethylene sheet 0.4 mm as
vapor barrier, formwork, reinforcement as specified in
standard drawings or Technical Specifications, reinforced
concrete curb 15 x 15 cm as indicated on construction
drawings and including whatever
necessary to give the work complete according to
construction drawings. Formation and sealing of joints as
described in items 1713-13 to 1713-16 are also included in
the price. The price includes also thickened edge.
1713-05 Concrete Road and Paving 15 cm thk SQM P.M.
The same as per item 1713-04, but with slab thickness of
15 cm.
1713-05A
Reinforced concrete road and paving thickness 15 cm class
30 N/mm2, all inclusive
SQM 4,113
The same as per item 1713-04A but with thickness 15 cm.
The price includes thickness edges
1713-06 Concrete Road and Paving 20 cm thk SQM P.M.
The same as per item 1713-04, but with slab thickness 20
cm.
1713-06A
Reinforced concreteroad and paving thickness 20 cm class
30 N/mm2, all inclusive
SQM 7,345
The same as per item 1713-04A but with thickness 20 cm.
The price includes thickness edges.
1713-07 Local upward or downward concrete works CBM P.M.
Local upward or downward concrete works, with fc as per
Technical Specifications, to support equipment, machinery,
etc., including form-works and excluding the
reinforcement bars only.
1713-08 Curbs in fc = 30 N/mm2, max dimensions 150 x 150 LM P.M.
Curbs in fc = 30 N/mm2, max dimensions 150 x 150, or as
specified on Technical Specifications and/or standard
drawings, including form-works and reinforcements bars.
1713-09
Supply ad application of hardener (dry mixture of hardener
and cement) by "dusting"
SQM P.M.
Supply ad application of hardener (dry mixture of hardener
and cement) by "dusting" over the surfaces as per items
1713-04 to 06. Type, quantity of hardener and cement shall
be as per Technical Specification and/or per construction
drawings.
1713-13
Surface check joints performed by cutting the necessary
depth and thickness
LM P.M.
Surface check joints performed by cutting the necessary
depth and thickness, and then sealing, according to the
specifications of Technical Specifications and/or on
standard
and/or project drawings.
1713-14
Construction and/or contraction joints for the whole
thickness,
LM P.M.
Construction and/or contraction joints for the whole
thickness, including the subsequent cutting and filling, as
specified in Technical Specifications and/or standard and/or
project
drawings.
1713-15 Isolation joints for the whole thickness, max. width 25 mm., LM P.M.
Isolation joints for the whole thickness, max. width 25 mm.,
filled as specified in Technical Specifications and/or
standard and/or project drawings.
1713-16 Expansion joints for the whole thickness, max width 25 mm LM P.M.
Expansion joints for the whole thickness, max width 25 mm,
with steel sleeve and spacing bars (total length within the
sleeve to be greased, or alternatively peripherally thickened
type), filled as specified in the Technical Specifications
and/or standard and/or project drawings.
1713-17
Supply and laying of sub-base with "stabilized corrected
earth"
CBM P.M.
Supply and laying of sub-base as above, but consisting of
"stabilized corrected earth" (raw materials being earth of
the" SOIL CLASSIFICATION", with the addition of type 325
normal PORTLAND cement).
1713-18 Laying only of sub-base with material from excavation CBM P.M.
Laying only of sub-base as described above being the
material coming from excavation.
1799-07 Concrete Road and Paving 25 cm thk SQM P.M.
The same as per item 1713-04, but with slab thickness 25
cm.
1799-08
Reinforced concrete road and paving thickness 25 cm class
30 N/mm2, all inclusive
SQM P.M.
The same as per item 1713-04A but with thickness 25 cm.
The price includes thickness edges.
1799-09
Cut of existing reinforced concrete paving or road with
thickness 25 cm maximum.
LM P.M.
Cut of existing reinforced concrete paving or road with
thickness 25 cm maximum.
Construction of pits and/or septic tanks, as indicated herein
below, in concrete as per Technical Specifications, as
indicated on the project drawings and/or standard drawings,
including lean concrete, reinforcement, form-works, pipe
and conduit holes, complete with concrete manhole cover.
In the case of metal ladder, manhole cover and frame, the
installation cost is included in the price. It is included in the
unit price the sealing of pipes and conduit inlet/outlet and
the levelling mortar eventually necessary for concrete cover
alignment.Excavation, transport, back-filling, cover and
frame and any metal ladder indicated in the said drawings
shall not be included in the supply.
1714-01
Sewer pits, with internal dimensions ranging from 0.50 x
0.50 m. to 0.90 x 0.90 m, max. 3.50 m deep.
CBM 11
Sewer pits, with internal dimensions ranging from 0.50 x
0.50 m. to 0.90 x 0.90 m, max. 3.50 m deep.
1714-02
Sewer pits with internal dimensions ranging from 0.91 x
0.91 m. to 1.50 x 1.50 m. max.4.00 m deep
CBM P.M.
1714-03
Puling pit with internal dimensions ranging up to 2,0 m x 2,0
m max depth 3,0 m
CBM 106
Puling pit with internal dimensions ranging up to 2,0 m x 2,0
m max depth 3,0 m, as per item 1714-01, for
electrical/instrumental underground cables, including final
sand filling.
1714-03A
Puling pit with internal dimensions ranging but with internal
dimensions from to 2,0 m x 2,01 m up to 2,0 m x 5,0 m and
max depth 3,0 m
CBM P.M.
As per item 1714-03 but with internal dimensions from to
2,01 m x 2,01 m up to 5,0 m x 5,0 m and max depth 3,0 m,
1714-05
Sanitary pit with internal dimensions up to 0,90 m x 0,90 m,
max depth 3,5 m
CBM P.M.
Sanitary pit with internal dimensions up to 0,90 m x 0,90 m,
max depth 3,5 m including final sand filling.
1714-05A
Sanitary pit with internal dimensions from to 0,91 m x 0,91
m up to 1,2 m x 1,2 m and max depth 5,0 m,
CBM P.M.
As per item 1714-05 but with internal dimensions from to
0,91 m x 0,91 m up to 1,2 m x 1,2 m and max depth 5,0 m.
1714-08 Supply only of cast iron covers KG 1,100
Supply only of cast iron covers as indicated in the project
drawings/standard drawings or Technical Specifications.
1714-10 Supply and installation of galvanized grating-type covers KG P.M.
Supply and installation of galvanized grating-type covers, as
indicated in the project and/or standard drawings, or
Technical Specifications.
1714-11A Supply only of galvanized grating-type covers KG P.M.
Supply only of the items as per item 1714-10.
1714-12 Supply and installation of checkered plate covers KG P.M.
Supply and installation of chequered plate covers as
indicated in the project and/or standard drawings or
Technical Specifications.
1714-13A Supply only of checkered plate covers KG 385
Supply only of the items as per item 1714-12.
1714-14 Supply and installation of steel frames KG P.M.
Supply and installation of steel frames, anchored in
concrete pits, for chequered plates/grating covers. The steel
profiles shall be painted with primer unless otherwise
indicated on project and/or standard drawings or Technical
Specifications.
1714-15A Supply only of steel frames KG 1,238
Supply only of items as per item 1714-14.
1799-06 Prefabricated concrete cover 20 cm thk SQM 22
Prefabricated concrete cover 20 cm thk as per construction
drawings. Item includes: selected material requirement,
transportation inside the plant, unloading, reinforcement
and installation as per Engineering Specification.
For Sub-Contractor duties refer to item 1711-11.
1714-31 Construction of underground cable trench in unpaved area CBM P.M.
Construction of underground cable trench in unpaved area
according to Engineering Standard. Including excavation,
transport of surplus material to dump area, back filling,
sand, red bricks or red concrete slab up to 500 mm
thickness, cable markers and whatever necessary to give
the work complete.
1714-32 Construction of underground cable trench in paved area CBM P.M.
Construction of electrical cable trench in paved area as per
Engineering standards including excavation, transport of
surplus material to dump area, backfilling, sand, red
bricks or red concrete slab up to 500 mm thickness, cable
markers and whatever necessary to give the work complete.
1714-34A Lighting pole foundation U 13
Lighting pole foundation as per Engineer standard including
excavation, transport of surplus material to dump area,
backfilling, lean concrete, concrete, reinforcement, PVC or
concrete sleeve and whatever necessary to give the work
complete. It is excluded from Sub-Contractor scope only
alignment and grouting operations.
1714-35A Execution of trench for lighting cables LM 330
Execution of trench for lighting cables as indicated on
construction drawings including excavation, transport of
surplus material, sand, backfilling, red brick protection and
cable markers as per Engineer standard and whatever
necessary to give the work complete.
1714-36A Execution of trench for grounding cables LM P.M.
As per item 1714-35A but for grounding cables.
1714-37A Execution of trench for cathodic protection cables LM P.M.
As per item 1714-35A but for cathodic protection cables.
1714-38A Execution of trench for anode LM P.M.
As per item 1714-35A but for anode.
1714-39A
Construction of electrical and instrument cable duct bank
all inclusive
CBM 39
Construction of electrical and instrument cable duct bank as
per Engineer standard including excavation, transport of
surplus material to dump area, backfilling, lean concrete,
PVC conduits, steel bars for conduit support, markers
embedded in the paving, and whatever necessary to give
the work complete.
1715-01
Supply and laying of lean concrete, blended with iron oxide
(10 kg of iron oxide per cubic meter of mix) to protect
electric cables buried directly underground (5 cm thk)
SQM P.M.
Supply and laying of lean concrete, blended with iron oxide
(10 kg of iron oxide per cubic meter of mix) to protect
electric cables buried directly underground (5 cm thk).
1715-02 Electrical cable marker for underground duct bank marking U P.M.
Electrical cable marker for underground duct bank marking.
Item includes: selected material requirement, transportation
inside the plant, unloading and installation as per
Engineering Specification.
1714-40
Reinforced concrete box culvert in traffic areas for storm
water system. Height from 300mm to 1000mm
CBM 35
Reinforced concrete box culvert in traffic areas for storm
water system.This item includes excavation, soil
compaction, formworks, concrete, reinforcing steel, steel
inserts, leveling plates as per construction drawings. The
height of the box culvert is variable from 300mm to
1000mm.
1714-41
Reinforced concrete box culvert in traffic areas for storm
water system. Height from 1001mm to 1500mm
CBM 32
Reinforced concrete box culvert in traffic areas for storm
water system.This item includes excavation, soil
compaction, formworks, concrete, reinforcing steel,steel
inserts, leveling plates as per construction drawings.The
height of the box culvert is variable from 1001mm to
1500mm.
1714-42
Reinforced concrete box culvert in traffic areas for storm
water system. Height from 1501 or bigger
CBM P.M.
Reinforced concrete box culvert in traffic areas for storm
water system.This item includes excavation, soil
compaction, formworks, concrete, reinforcing steel,steel
inserts, leveling plates as per construction drawings.The
height of the box culvert is 1501mm or bigger.
1714-43
Reinforced concrete trench in traffic areas for storm water
system. The height of the trench is variable from 300mm to
1000mm
LM 1,586
Reinforced concrete trench in traffic areas for storm water
system. This item includes excavation, soil compaction,
formworks, concrete, reinforcing steel, steel inserts,
levelling plates and grating cover as per construction
drawings.
1714-44
Reinforced concrete trench in traffic areas for storm water
system. The height of the trench is variable from 1001mm
to 1500mm
LM 0
Reinforced concrete trench in traffic areas for storm water
system. This item includes excavation, soil compaction,
formworks, concrete, reinforcing steel, steel inserts,
levelling plates and grating cover as per construction
drawings. The height of the trench is variable from 1001mm
1714-45
Reinforced concrete trench in traffic areas for storm water
system. The height of the trench is 1501mm or bigger.
LM 0
Reinforced concrete trench in traffic areas for storm water
system. This item includes excavation, soil compaction,
formworks, concrete, reinforcing steel, steel inserts,
levelling plates and grating cover as per construction
drawings.
1714-46
R.C. Trench for water drainage for acid areas with AISI
316L. Internal section up to 500mm wide / up to 500mm
high
LM 211
Reinforced Concrete Trench for water drainage for acid
areas as per Engineering Specification; the concrete trench
shall be integrally poured together with the adjacent
concrete paving.This item includes:
- excavation and soil compacting,
- concrete (minimum yield strength 30 N/mm2),
- reinforcement, steel inserts, levelling plates and splash
cover,
- AISI 316L stainless Steel Lining and Grating or concrete
cover.
- all materials to make the work complete excluding
monolithic topping on paving.
- internal section up to 500mm wide / up to 500mm high
(see SKETCH A)
1714-47
R.C. Trench for water drainage for acid areas with AISI
316L. Internal section up to 501mm to 600 wide / from 501
up to 700mm high
LM P.M.
R.C. Trench for water drainage similar to Item 1714-46 but
having internal section from 501mm to 600 wide / from 501
up to 700mm high (see SKETCH A).
1714-48
R.C. Trench for water drainage for acid areas with AISI
316L. Internal section from 601 mm to 700 wide/from 501 to
900 high.
LM 801
As per item 1714-46, but with internal section from 601 mm
to 700 wide/from 501 to 900 high (see SKETCH A).
1714-49
R.C. Trench for water drainage for non acid areas up to
400 wide, up to 500 high
LM 242
R.C. Trench for water drainage for non-acid areas as per
Engineering Specification. The concrete trench shall be
integrally poured together with the adjacent concrete
paving.
This item includes:
- excavation and soil compacting ,
- concrete (minimum yield strength 30 N/mm2)
- reinforcement , steel inserts and splash cover
- galvanized carbon steel grating or concrete cover
- all materials to make the work complete the work
excluding monolithic topping on paving.
- internal section up to 400mm wide/up to 500mm high (see
1714-50
R.C. Trench for water drainage for non acid areas internal
section from 401mm to 600 wide / from 501 up to 700mm
high
LM P.M.
R.C. Trench for water drainage similar to Item 1714-49 but
having internal section from 401mm to 600 wide / from 501
up to 700mm high (see SKETCH A).
1714-51
R.C. Trench for water drainage for non acid areas internal
section from 601mm to 800 wide / from 501 up to 700mm
high
LM P.M.
R.C. Trench for water drainage similar to Item 1714-49 but
having internal section from 601mm to 800 wide / from 501
up to 700mm high (see SKETCH A).
1714-52
R.C. Trench for water drainage for non acid areas internal
section from 801mm to 1000 wide / from 701 up to 1000mm
high
LM P.M.
R.C. Trench for water drainage similar to Item 1714-49 but
having internal section from 801mm to 1000 wide / from 701
up to 1000mm high (see SKETCH A).
1714-53
R.C. Trench for water drainage for non acid areas internal
section over 1001mm wide / over 1001mm high
LM P.M.
R.C. Trench for water drainage similar to Item 1714-49 but
having internal section over 1001mm wide / over 1001mm
high (see SKETCH A).
1714-54
R.C. Trench for water drainage for non acid areas internal
section from 401 mm to 600 wide/from 501 to 1200 high.
LM P.M.
As per item 1714-49 but with internal section from 401 mm
to 600 wide/from 501 to 1200 high (see SKETCH A).
1717-01 Supply and casting of foundation concrete for basin CBM 176
Supply and casting of foundation concrete for basin having
fc not less than as specified in Technical Specification
and/or Construction Specifications.
1717-02 Supply and casting of elevation concrete for basin CBM 275
Supply and casting of elevation concrete for basin (at any
height) with fc not less that as specified in the Technical
Specification and/or Construction Specifications.
1717-03 Supply and laying of water-stops of PVC, 20 cm wide LM 108
Supply and laying of water-stops made of PVC, 20 cm wide,
shaped as per drawings or as per approved sample, to be
used for construction joints, to be placed within the steel
reinforcement, including suitable fixing to the steel bars,
welding at junctions and including all other operations and
duties necessary to complete the works according to
the Contract Specifications.
1717-04 Supply and laying of water-stops of PVC, 30 cm wide LM P.M.
As per item 1717-03 above, except that the water-stop shall
have a minimum width of 30 cm and profile suitable for
installation at the expansion joint of the structure.
1717-07 Supply and laying of water-stops of rubber 20cm wide LM P.M.
As per item 1717-03 except that the water-stop shall be
made of rubber in accordance with the requirements of the
Technical Specifications.
1717-08 Supply and laying of water-stops of rubber 30cm wide LM P.M.
As per item 1717-04 except that the water-stop shall be
made of rubber in accordance with the requirements of the
Technical Specifications.
1717-12 Sealing of expansion joints LM P.M.
Sealing of expansion joints (including supply and laying of
joint filler, primers and sealant) to be made in accordance
with the requirements and procedures of the Technical
Specifications, including all duties and charges.
1717-13
Supply and laying of 5mm thickness AISI 316L preformed
sheet lining for concrete sump basin
KG 11,000
AISI 316L sheet lining 5 mm thk . Supply and laying of 5mm
thickness AISI 316L preformed sheet lining including steel
anchoring, head-to-head welding along the entire perimeter
of prefabricated sheets and all other activities for concrete
sump basin as per Construction drawings, including tests
as per INDIAN Code.
1717-14 Stainless Steel Grating AISI 316L. KG 90
Stainless Steel Grating AISI 316L. Supply and installation of
gratings mesh 30x50 mm plate 25x3 mm.
1717-15 Cement mortar for slope in concrete basins CBM 8
Cement mortar for slope. Mortar shall be used as finishing
in concrete basins for slope, or to reach final design
elevation or to reduce as little as possible the concrete
irregularities.
Thickness may be in range of 2-10 cm. Mortar shall have
500 kg of cement per cubic meter and may be added with
gravel
(maximum size 10 mm). Sub-Contractor duties as per item
1731-01 Supply of precast foundation CBM P.M.
Supply of precast foundation. Supply of prefabricated
concrete foundations for pre-cast frame. Including
excavation, back-filling, transport of surplus material, lean
concrete thick 10 cm, formworks, reinforcement (in the ratio
of 120 kg/ m3), protruding dowels, curing, storage, handling
in the refabrication yard or in the shop. Transportation from
Shop and Off Loading to site, transportation from
prefabrication yard to site (if any). Including erection,
alignment, shop drawings: production drawings (include
bars bending schedule and bar placement drawings) and
Erection drawings as per technical Specification.Including
all labor, equipment and supervision activities.Excluding
anchor/ headed bolts/ pin connection, cast in situ joints with
non-shrinking concrete and coating.
1731-02 Erection of precast foundation. CBM P.M.
Erection of precast foundation. Including levelling plate or
templates.Including all loading/ unloading operations
prefabrication yard-storage area- site and handling within
battery limits. Including all labor, equipment and supervision
activities. Excluding anchor/ headed bolts/ pin connection,
cast in situ joints with non-shrinking concrete.
1731-03
Supply of pre-cast elements (frame and beam) for pipe-
rack.
CBM 1,089
Supply of pre-cast elements (frame and beam) for pipe-
rack.
Supply of prefabricated concrete elements having cross
section of any dimensions but not heaviest of 110 tons.
Including formworks, reinforcement (ratio of 280 kg/ m3 with
5%, material and rebar type according to MS 1731)
curing, stripping, storage, handling in the prefabrication yard
or in the shop. Including embedded items, insert plate (ratio
of 55 kg/m3) and sleeves. Transportation from Shop and
Off Loading to site, transportation from prefabrication yard
to site (if any). Including shop drawings: production
drawings (include bars bending schedule and bar
placement drawings) and Erection drawings as per
technical Specification.
Including all labor, equipment and supervision activities.
Exclusion as per item 1731-01.
1731-04
Erection of pre-cast elements (frame and beam) for pipe-
rack.
CBM 1,089
Erection of pre-cast elements (frame and beam) for pipe-
rack. Including leveling plate, no shrinking grouting for
leveling plates, approved template for positioning of frame
with correct alignment. Including all loading/unloading
operations prefabrication yard-storage area- site and
handling within battery limits. Including all labor, equipment
and supervision activities.
1731-05
Variation 5% for reinforcement weight for items 1731-01 and
1731-03.
KG P.M.
and 1731-03.Deduction or increasing of price of above
items for reinforcement weight variation. Variation within
5% in weight of reinforcement ratio, measured on overall
volume of precast elements supplied, stated in above said
items shall not be accounted and paid. Only variation
exceeding 5% the specified ratio, shall be accounted in
addition or deduction.
1731-06
Variation 5% for weight of steel inserts for items 1731-01 and
1731-03.
KG P.M.
and 1731-03. Deduction or increasing of price of above
items for weight of steel insert variation. Variation within
5% in weight of steel ratio, measured on overall volume of
precast
elements supplied, stated in above said items shall not be
accounted and paid. Only variation quantities exceeding
5% the specified ratio shall be accounted in addition or
deduction.
1731-08 Supply and installation of steel pins. KG 275
Supply and installation of steel pins. Supply and installation
of steel pins as per IFC drawings and technical
specifications.
1731-09
Supply and installation of NMB splice sleeve with frustum-
conical geometry.
U 910
Supply and installation of NMB splice sleeve with frustum-
conical geometry. Supply and installation of NMB splice
steel sleeves with frusto-conical geometry, including non-
shrinking grout type SS Mortar or equivalent, coil springs
and whatever is necessary to complete the supply are
included.
1731-12 Installation only of NMB splice sleeve system. U 891
Installation only of NMB splice sleeve system.
As per item 1731-09 but only installation.
1731-14 Above ground coating for precast and cast in situ joints. SQM 869
Above ground coating for precast and cast in situ joints.
Supply, application, touch-up or repair, of one or more layer
as indicated on the IFC drawings and/or in MS1731 and/or
Construction Specifications.
1731-15 Underground coating for precast foundations. SQM P.M.
Underground coating for precast foundations. Supply,
application, touch-up or repair, of one or more layer as
indicated on the IFC drawings and/or in MS1731 and/or
Construction Specifications.
1731-18 Supply and installation of expansion joints. SQM P.M.
Supply and installation of expansion joints. Supply and
installation as per IFC drawings, and project and technical
specifications of stainless steel plate thick 2 mm, Teflon pad
thick 6 mm and galvanized insert for Teflon
accommodations.
1731-20 Supply and installation of non-shrinking grout. CBM 99
Supply and installation of non-shrinking grout. Supply and
installation of non-shrinking grout, sleeves, joints according
to project specifications.
1731-21 Supply and installation of galvanized steel. KG P.M.
Supply and installation of galvanized steel. Supply and
installation of metal components in galvanized steel, such
as plates, angles, etc, exclusion those embedded
(completely or partially) in pre-cast elements, completely or
partially embedded in cast in situ concrete or necessary to
complete the joints as specified in project drawings and/or
in Technical Specifications
1741-02
Internal and external coatings of metal skirts of vertical
equipment
CBM P.M.
Internal and external coating of metal skirts of vertical
equipment (thickness variable from 5 to 10 cm).
1741-03
Coating of curved bottoms for vertical vessels (thickness
variable from 5 to 10 cm)
CBM P.M.
Coating of curved bottoms for vertical vessels (thickness
variable from 5 to 10 cm).
1741-04 External kerbs of metal skirts CBM P.M.
External kerbs of metal skirts. Installation of fire proofing for
steel elements, using 5 cm thick sprayed cement mortar,
consisting of aggregates 100% passing through the 4.75
sieve (small granulometry aggregates as per INDIAN Code)
and cement, mixed at a ratio of 3:1 (by weight), including
supply and installation of the mesh reinforcement and
hooks, mastic sealing between the concrete layer edge and
the metal structure, according to the specifications of
Technical Specifications and/or construction drawings.
1741-06
Internal and external coatings of metal skirts of vertical
equipment
SQM P.M.
Internal and external coatings of metal skirts of vertical
equipment
1741-07 Coating of curved bottom of vertical vessels SQM P.M.
Coating of curved bottom of vertical vessels.
1741-08 External kerbs of metal skirts SQM P.M.
External kerbs of metal skirts.
1741-09
Supply and installation of fire proofing FENDOLITE MII
Type for steel structures
SQM P.M.
Supply and installation of fire proofing FENDOLITE MII
Type, 40 mm thickness, according to Vendor instruction, for
steel structure including supply and installation of reinforced
mesh with dimension and type as per Vendor specification,
mastic sealing and all activities and materials to perform the
works.
1741-10
Supply and installation of fire proofing FENDOLITE MII
Type for internal and external vessel skirt
SQM P.M.
As per item 1741-09, but for internal and external vessel
skirt.
1741-11
Supply and installation of fire proofing FENDOLITE MII
Type for vessel bottom
SQM P.M.
As per item 1741-09, but for vessel bottom.
1741-12
Supply and installation of fire proofing FENDOLITE MII
Type for skirt curb
SQM P.M.
As per item 1741-09, but for skirt curb.
1741-13
Dense Concrete Fireproofing for steel structure members
with hollow section H<300 mm
CBM 20
Fireproofing for steel structure members with hollow section
H<300 mm or any shape and profile less than 300 mm high
using Dense Concrete aggregates. Materials supply and
installation included in accordance to the Engineering and
Job Specification. Fireproofing can be applied before or
after the member installation in accordance to the
Contractor instruction. Dense Concrete fireproofing shall be
applied from 0.00 up to 2.10 m from pavement.
Price includes: - temporary scaffolding;
- supply and installation of wire mesh and steel connection
to the member,
- protection of adjacent surfaces during the installation
- supply and installation of dense concrete as per Job
Specification
- finishing of the surface in accordance to the specs
- top primer coating (epoxy paint specific for fireproofing)
2 coats.
Minimum thickness of concrete shall be 50 mm around the
contour of the shape. Accounting is by theoretical volume
based on overall dimension of shape plus 50 mm both
sides.
1741-14
Dense Concrete Fireproofing for steel structure members
(Contour type) with section H>=300mm
CBM 10
Fireproofing for steel structure members (Contour type) with
section H>=300mm or any shape and profile equal or more
than 300mm high using Dense Concrete aggregates.
Materials supply and installation as per Item 1741-13.
Minimum thickness of concrete shall be 50 mm around the
contour of the shape. Accounting is by theoretical volume
based on effective contour of the shape plus 50 mm
both sides.
1741-15
Light Concrete Fireproofing for steel structure members with
hollow section H < 300mm
CBM P.M.
Fireproofing for steel structure members with hollow section
H < 300mm or any shape and profile less than 300mm high
using Light Concrete aggregate as per applicable
Indian Std.s. Materials supply and installation as per Item
1741-13. Light Concrete fireproofing shall be applied from
2.10 up to 10.5 mt from pavement. Minimum thickness of
concrete shall be 50 mm around the contour of the shape.
Accounting is by theoretical volume based on overall
dimension of shape plus 50 mm both sides.
1741-16
Light Concrete Fireproofing for steel structure members
(Contour type) with section H > 300mm
CBM P.M.
Fireproofing for steel structure members (Contour type) with
section H > 300mm or any shape and profile equal or more
than 300 mm high using Light Concrete aggregate as per
applicable Indian Std.s. Materials supply and installation as
per Item 1741-13. Light Concrete fireproofing shall be
applied from 2.10 up to 10.5 m from pavement. Minimum
thickness of concrete shall be 50 mm around the contour of
the shape.
Accounting is by theoretical volume based on effective
contour of the shape plus 50 mm both sides.
1761-01
Lining of concrete surfaces made of acid-resistant tiles laid
with acid-resistant mortar
SQM 3,207
Lining of concrete surfaces (both horizontal and vertical)
made of acid-resistant tiles laid with acid-resistant mortar,
including cutting of tiles, sealing of points with acid-resistant
Lining of concrete surfaces (both horizontal and vertical)
made of acid-resistant tiles laid with acid-resistant mortar,
including cutting of tiles, sealing of points with acid-resistant
1763-01 Coating of concrete surfaces made of antacid epoxy-resins SQM P.M.
Coating of concrete surfaces (both horizontal or vertical
surfaces) made of antacid epoxyresins applied in
subsequent coats by roll or brush, on suitable primer. Type
of primer, resins, filler, glass fiber reinforcement if required,
thickness and number of coats shall be in accordance with
the requirements of the Technical Specifications.
Note:
1. Item with P.M. (per memory) need to be considered as alternative
solution and/or for future application.
2. De-watering (well points) of general excavated areas, shall be kept
in operation during the period of all civil works.

Potrebbero piacerti anche