Sei sulla pagina 1di 1

Project Control No.

:
Project Title:
160 Panay Ave., Cor EDSA, Quezon City
1103 Philippines Client: Maynilad
Tel. No. 928-6533 415-8782 Fax No. Subj. Title: UBC Design Criteria
924-1865 924-1931
(632) 924-1887
Date: 2014 JUNE
A. Minimum Design Loads
I. DEAD LOADS Sect. 204
Unit Weight of Concrete 23.6 kN/m
3
Tbl. 204-1 Reinforced Concrete, Stone (including gravel)
Unit weight Soil 18 kN/m
3
To be verify
Unit Weight of Steel 77.8 kN/m
3
Tbl. 204-1
Unit Weight of Glass 25.1 kN/m
3
Tbl. 204-1
CEILINGS
Gypsum Board (per mm thickness) 0.128 kPa Tbl. 204-2 Gypsum board 5/8 in. thick = 16mm thk
Mechanical Duct Allowance 0.2 kPa Tbl. 204-2
Plaster on Tile or Concrete 0.24 kPa Tbl. 204-2
Metal Furring 0.12 kPa Tbl. 204-2
COVERINGS, ROOF and WALL
Deck, Metal, 20 Gage 0.12 kPa Tbl. 204-2
Deck, Metal, 18 Gage 0.14 kPa Tbl. 204-2
Rigid Insulation 0.04 kPa Tbl. 204-2 0.16 kPa
Water Proofing Membranes 0.07 kPa Tbl. 204-2 Bituminous, Smooth Surface
FRAME WALLS
Windows, Glass, Frame and Sash 0.38 kPa Tbl. 204-2
FLOOR FILL
Stone concrete, per mm 0.023 kPa Tbl. 204-2 For Slab Weight
FLOOR FINISHES
Ceramic Tile 0.77 kPa Tbl. 204-2
CONCRETE MASONRY UNITS
Hollow Concrete Masonry 2.97 kPa Tbl. 204-2 150mm Whyte thickness, 21.2 kN/m
3
, Full Grout
Plastering 0.48 kPa Tbl. 204-2 Plastered both face
II. LIVE LOADS Sect. 205
FLOOR LIVE LOADS
Dinning Rooms and Restaurants 4.8 kPa Tbl 205-1
Storage
Light 6 kPa Tbl 205-1
Heavy 12 kPa Tbl 205-1
ROOF LIVE LOADS
1 kPa Tbl 205-3 0 to 20 sq.m Tributary Area
III. EARTHQUAKE LOADS Sect. 208
Occupancy Category III. Tbl. 103-1 IV.Standard Occupancy Structures
Seismic Importance Factor 1.00 Tbl. 208-1 IV.Standard Occupancy Structures
Soil Profile Type S
D Tbl. 208-2 Stiff Soil Profile
Seismic Zone 4 Fig. 208-4 Region IV: Cavite
Seismic Zone Factor 0.4 Tbl. 208-3 Zone 4 Region IV: Cavite
Near Source Factor, N
a 1.00 Tbl. 208-4 Closest distance to Valley Fault Line >10m
Near Source Factor, N
v 1.00 Tbl. 208-5 Closest distance to Valley Fault Line >15km
Seismic Source Type A Tbl. 208-6 M 7.0
Seismic Coefficients, C
a 0.44 Na 0.44 Tbl. 208-7
Seismic Coefficients, C
v 0.64 Nv 0.64 Tbl. 208-8
Numerical coefficient, Ct 0.0731 Sect. 208.5.2.2 RC Moment resisting frames
Earthquake-Force-Resisting Structural System of Concrete Moment Resisting Frame System
Numerical coefficient, R 8.5 Tbl. 208-11B Special RC Moment-Resisting Frame SMRF
B. Allowable Stresses
Concrete Compressive Strength, fc'
Columns, Beams, ShearWalls, Slabs 28.00 MPa
Steel Yield Strength, fy
Main Reinforcement 414 MPa 16 mm bar diameter and above
Secondary Reinforcement 276 MPa 12 mm bar diameter and below
Soil Bearing Capacity 75 kPa
C. References
NSCP 2010 Vol. 1 Sixth Edition
D. Basic Load Combinations using Strength Design or Load and Resistance Factor Design
1) EQX EQX - Earthquake Load along X direction
2) EQZ EQZ - Earthquake Load along Z direction
3) DL DL - Dead Load
4) LL LL - Live Load
5) 1.4DL Sect. 203.3.1 Eq. (203-1)
6) 1.2DL+1.6LL Sect. 203.3.1 Eq. (203-2)
7) 1.2DL+1.0EQX + 1.0LL Sect. 203.3.1 Eq. (203-5)
8) 1.2DL+1.0EQZ + 1.0LL Sect. 203.3.1 Eq. (203-5)
Pitch Roof with slope = 28.56 %
ANGEL LAZARO & ASSOCIATES INTERNATIONAL
Consulting Engineers and Architects
SD-WTC
Proposed Food Kiosk
1 of 1

Potrebbero piacerti anche