Sei sulla pagina 1di 3

Nominal voltage

Flash frequency
Lamp failure flash frequency
12VDC / 24VDC
9VDC to 16VDC
18VDC to 32VDC
221W + 5W
2(221W + 5W)
21W + 5W
(60 to 110)OPS / min
(140 to 230)OPS / min
1000h
360h
400h
200h
Nominal load
Electrical
endurance
106
Operating
voltage
Duty cycle
Ambient temperature
Vibration resistance
Shock resistance
Unit weight
30% to 70%
-40 to 85
10Hz to 200Hz 49m/s
2
196m/s
2
Approx.40g
160N min.
100N min.
Mechanical
performance
Type
Turning mode
Hazard mode
Lamp outage mode
12V System
24V System
Turning 15s on/15s off 12V
Hazard continuously 12V
Hazard continuously 24V
Turning 15s on/15s off 24V
Cover retention
Terminal retention
HF3501 HF3508
12VDC
9VDC to 16VDC

221W + 5W
2(221W + 5W)
21W + 5W
(60 to 110)OPS / min
(140 to 230)OPS / min
1000h
360h

30% to 70%
-40 to 85
10Hz to 200Hz 49m/s
2
196m/s
2
Approx.30g
160N min.
100N min.
Type Product series name Dimensions Output mode
HF3501
HF3508
1)
Automotive flasher
Miniature automotive flasher
(30 30 40) mm
(30 30 30) mm
Single output
Single output
1) The application of HF3508 series can be expanded to halogen lamp load of (21W+5W)+5W(LED).
Features
Turn signal & Hazard warning lamp control
TypicaI AppIications
2012 Rev. 1.01
HONGFA RELAY
SO9001, SO/TS16949 , SO14001, OHSAS18001, ECQ QC 080000 CERTFED
HF3501
/ HF3508
Special integrate circuit, good performance
Special high-performance contacts,
ultra-long Electrical endurance
ncluding LED / halogen lamp load
Surface mounting technology, advanced craftwork
Solid base design, stable structure
ngress protection: P52
B
B
B
B
B
B
TYPE
FLASHER
CHARACTERISTICS
107
OUTLNE DMENSONS
(Bottom view)
(Bottom view)
HF3501/__-H-_(XXX) HF3501/__-H-B_(XXX)
OUTLINE DIMENSIONS, WIRING DIAGRAM
Unit: mm
Mounting mode B: With bracket NiI: without bracket
Customer speciaI code
(XXX)
Suffix (A-Z) is for specific
extending application
1) When there is other special requirement, please contact Hongfa for more technical support.
HF3501 /
HF3508 /
-H 12 -B R
ORDERING INFORMATION
Type
NominaI voItage
Contact arrangement H: 1 Form A
PoIarity Iogic R: Reverse polarity NiI: Normal
12: 12VDC
24: 24VDC (Only for HF3501)
9
.
9
0
.
2
31 49
49a
8
.
4
0
.
2
16.9
0.2
(E)
(B)
(L)
30
0.5
9
.
9
0
.
2
31 49
49a
8
.
4
0
.
2
16.9
0.2
18
0.5
(E)
(B)
(L)
30
0.5
30
0.5
4
0
0
.
5
3-0.8
0.05
6.3
0.1
A
1
1
.
5
0
.
5
3-1.8
A
1
0.1
2.6
0.3
30
0.5
2
1
.
5
0
.
5
1
6
.
5
0
.
5
4
0
0
.
5
6.5
0.3
14.8
0.5
2
5
1
7
1
1
1
.
5
0
.
5
3-6.3
0.1
3-0.8
0.05
3-1.8
108
OUTLNE DMENSONS
HF3508
Positive
Reverse
HF3501
Positive Reverse
(Bottom view)
(Bottom view)
HF3508/12-H-_(XXX) HF3508/12-H-B_(XXX)
WRNG DAGRAM
Disclaimer
This datasheet is for the customers' reference. All the specifications are subject to change without notice.Before referring to this datasheet, please
make sure that you have read and understood "Explanation to Terminology and Guidelines of Automotive Relay & Module" in our catalogue of
Automotive Relay & Module.
n case there is specific criterion (such as mission profile, technical specification, PPAP etc.) checked and agreed by and between customer and Hongfa,
this specific criterion should be taken as standard regarding any requirement on Hongfa product.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose
the suitable product for their own application. f there is any query, please contact Hongfa for the technical service. However, it is the user's responsibility
to determine which product should be used only.
Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
OUTLINE DIMENSIONS, WIRING DIAGRAM
Unit: mm
49a 49 31 L B E
As shown in wiring diagram, the terminal 49(B) is connected with
positive electrode of power supply of 12V or 24V. The 31(E) terminal
is connected with negative electrode of power supply, the 49a(L) is
connected with lamp load. When lamp load is 2 x 21W + 5W or 4 x
21W + 2 x 5W, the flasher will control lamp to flash by the frequency
of (60 to 110) times per minutes. When lamp load is 1 x 21W + 5W
(one lamp of 21W is broken down), the flasher will control lamp to
flash by frequency of (140 to 230) times per minutes.
1)
49a 49 31 L B E
As shown in wiring diagram, the terminal 49(B) is connected with
positive electrode of power supply of 12V. The 31(E) terminal is
connected with negative electrode of power supply, the 49a(L) is
connected with lamp load. When lamp load is 2 x 21W + 5W or 4 x
21W + 2 x 5W, the flasher will control lamp to flash by the frequency
of (60 to 110) times per minutes. When lamp load is 1 x 21W + 5W
(one lamp of 21W is broken down), the flasher will control lamp to
flash by frequency of (140 to 230) times per minutes.
1)
31 49
49a
9
.
9
0
.
2
8
.
4
0
.
2
16.9
0.2
A
30
0.5
3
0
0
.
5
3-0.8
0.05
6.3
0.1
1
1
.
5
0
.
5
3-1.8
30
0.5
(E)
(B)
(L)
6.5
0.3
14.8
0.5
2
5
1
7
1
1
0.1
2.6
0.3
30
0.5
1
1
.
5
0
.
5
1
6
.
5
0
.
5
3
0
0
.
5
1
1
.
5
0
.
5
3-6.3
0.1
3-0.8
0.05
3-1.8
A
31 49
49a
9
.
9
0
.
2
8
.
4
0
.
2
16.9
0.2
30
0.5
18
0.5
(E)
(B)
(L)

Potrebbero piacerti anche