0 valutazioniIl 0% ha trovato utile questo documento (0 voti)
75 visualizzazioni47 pagine
A condition in the distribution system where it could damage, or create condition that will damage components of the distribution system is termed as Excessive water pressure. Which plastic pipe can be joined by solvent cement? which plastic material is generally used for pipes and fittings which can exclusively used for cold water lines, sprinkler and irrigation systems?
A condition in the distribution system where it could damage, or create condition that will damage components of the distribution system is termed as Excessive water pressure. Which plastic pipe can be joined by solvent cement? which plastic material is generally used for pipes and fittings which can exclusively used for cold water lines, sprinkler and irrigation systems?
A condition in the distribution system where it could damage, or create condition that will damage components of the distribution system is termed as Excessive water pressure. Which plastic pipe can be joined by solvent cement? which plastic material is generally used for pipes and fittings which can exclusively used for cold water lines, sprinkler and irrigation systems?
damage components of the distribution system or create a nuisance is termed as Excessive water pressure Excessive air pressure Loss of air pressure Loss of water flow Which plastic pipe can be joined by solvent cement?
uPVC PB PE All of the above
A plumbing appurtenance
P-trap Plug Single-point water heater Faucet
What plastic material is generally used for pipes and fittings, which can be exclusively used for cold water lines, sprinkler and irrigation systems? Polythelene Polyethylene Plastic Polybutylene
Which of the following is not a sanitary fixture
Stall Urinal Waterless urinal Floor Drain Clean-out What specific law governs and states the specific type of bodies of water and their corresponding owners
National plumbing Code of the Philippines, as amended 2009 Water Code of the Philippines DENR Memorandum 5-5, series of 2010 RA 1877
If there are only two water closets provided at the temfacil of a construction site, how many can they serve as per NPCP 30 60 90 120 Validity period of plumbing permit after work stoppage
1 year 6 months 120 days 2 years A pump, manually operated and is used to remove water from the cistern during Maintenance or during foundation excavation
Submersible pump Jet pump Hand pump Booster pump
Minimum diameter of downspout
50 mm 63 mm 75 mm 100 mm
Which of the following fixtures is best for public use?
Gate valve Flushometer Faucet None of the above
What is used to connect plastic pipes?
Sealant Solvent Cement Cement As per manufacturers recommendations
The following are brands of plumbing pipes except
neltex super pipes moldflex sanimold
Vernacular term for gutter drain tailpiece usually made of GI sheet which is used to hold the leader elbow fitting
Gatang-gatang Abang Buntot Tali Used to remove burrs around pipes
pipe reamer pipe burrer pipe scaler pipe wrench
Minimum standard center-to-center distance of two lavatories
26 30 45 60 When there is a low pressure from the water main, what will you use to supply water to higher levels Jockey pump Centrifugal pump Booster pump Pneumatic pump
A type of wrench designed for use under sinks and in other tight quarters Torque wrench Basin Wrench Ordinary Wrench Strap wrench
A valve in which the flow of water is cut-off by means of a circular disc fitted against machine smoothed faces, at right angles to the direction of flow. The disk is raised or lowered by means of a threaded stem connected to the handle of the valve. The opening in the valve is usually as large as the full bore of the pipe. Globe valve Check valve Gate valve Butterfly valve A grease interceptor of at least 3 cubic meters capacity to serve one or more fixtures and which are remotely located? Grease trap Grease interceptor Grease chamber None of the above
A tankless water heater is: Only available in gas Only available in electric Only capable of storing 10 gallons Available in gas and electric
A type of pipe support that requires a threaded rod, nut and washer
Clevis Stub-out bracket Clips U-bolt It is an approved elastomeric sealing gasket with an approved outer shield and a tightening mechanism
Shielded coupling Structural coupling Coupler All of the above
What type of pipe is commonly used for Wet Stand Pipes?
G.I. B.I. PP-R ABS
Minimum slope of sanitary pipe? 0.5% 1% 2% 3% What fitting combination is used to connect the vent stack to the soil stack?
45 degree elbow and santee Inverted wye and 1/8 bend Tee and coupling reducer Sanitary tee and straight wye
It is usually seen at basement parking which hung pipes using strings and hangers.
U bolt Cable tray Eye bolt Angle bar
Type of pump used to eject waste/liquid
Centrifugal Rotary Ejector Jockey
By law, who is in charge of the plumbing layout of buildings?
Master Plumber Mechanical Engineer Sanitary Engineer Professional Engineer
What is the standard water consumption (gallon/person/day) used in a 2-storey residence? 20-30 40 60 30 40 100 120
Which is used for sanitary pipes? PeX PP GI uPVC
What is the standard water consumption used in the design of a water distribution system of a 2-storey residence? 100 LPCD 150 LPCD 180 LPCD 200 LPCD What would be the consideration when providing a septic tank?
Site configuration Location of the water supply Weather Capacity of the septic tank
What is the kind of pipe that is NOT suited for ultraviolet rays? PVC Iron PB All of the above
It is a plumbing appurtenance near the water tank used to cut-off supply. Globe valve Pressure valve Check valve Gate valve
When the water coming out from the faucet is contaminated, what could be the possible reason? Rust Theres a hole in the pipe Too much water pressure Crossing of sanitary and water supply pipes
Air pressure in drainage pipes greater than atmospheric pressure
standard pressure back pressure normal pressure barometric pressure
A pipe fitting use to reduce an opening
Bushing Nipple Reducer Union
The minimum pressure that should be maintained for fixtures containing flush tank water closets shall be 8psi 30 psi 4.34 psi 434 psi
Sizes of vertical and horizontal drainage pipe shall be determined from type of building number of bathroom installed location of fixtures total fixtures units
The critical level marking or a backflow prevention device or vacuum breaker is a point established by the Testing laboratory Health officer Inspector Manufacturer
Ratio of domestic water supply to fire reserve for a single cylindrical tank? 2/3 : 1/3 : : 1/5 :1/4
Density of water 62.4 lbs 56.4 lbs 36.4 lbs 70.4 lbs
There are several reasons why soil stacks are not allowed inside columns. Which is NOT a reason? Pipes will interfere with reinforcing bars The size of the columns will be larger Cracks and leaks cannot be detected The gas emitted will deteriorate concrete
What type of material is usually used for the base of a septic tank? Earth base Mass concrete Reinforced concrete Crushed gravel