Sei sulla pagina 1di 11

Air CooIing / VentiIation

www.humidin.com

H
e
n

/

M
o
r
e

C
o
r
t
e
a
t
h
i
r


d
o
o
r

A
i
r
o
m
f


B
e
t
e
r

P
r
o
u
c
t
v
i
t
/

L
o
w

E
n
e
r
g
y

C
t
t
d
i
y

o
s



Comfort conditioning
ndustrial Ventilation Cooling
Pre cooling for DG sets, Compressors,
Gas turbines
Hybrid Air Conditioners
100% fresh air applications
Retrofits to existing AHU's and Chillers
An evaporative cooler produces effective cooling by
combining a natural process water evaporation with
a simple reliable air-moving system. Fresh outside air
is pulled through moist pads, where it is cooled by
evaporation and circulated through a house or building
by a blower.
SUITABLE FOR.
MALLS & SHOPPNG
STAR HOTELS
CALL CENTES
GARMENT UNTS
ENGNEERNG UNTS
NDUSTRAL UNTS.
nnovative
S O L U T O N S
COMPARSON
Evaporative Air CooIing
1. ntroduces 100% fresh air .
2. Windows and doors left open.
3. Keeps the air moist, great for allergy and
asthmatic conditions.
4. Full ventilation exhausts odors, germs.
5. ncreased cooling capacity as outside
temperature rises.
6. 70% Less than the installation costs of air
conditioning.
7. 90% Less than the running costs of air
conditioning.
Air Conditioning
1. Re-cirulates the same stale air .
2. Windows and doors must be shut.
3. Reduces the moisture, which can be bad for
asthma and allergy sufferers.
4. Re-circulated air can contain germs and
airborne contaminants.
5. Reduced efficiency and capacity as outside
temperature rises.
6. Costly nstallation.
7. Higher running costs.
Ambient Dry Bulb

Temperature( C)


PERCENTAGE RELATVE HUMDTY
Evaporative Cooler Temperature Drop Chart

1
Salient Features of Single Skin &
Double Skin Air Washer
Corner Cast ron PVC
Sheet Metal 16 G. G.. 24 G.. - P.P. Sheet Outside
24 G.. G nside
nsulation No nsulation Puf nsulation CFC Free
Base 100mm C Channel 100 mm C Channel
Tank MS / SS MS / SS
Filter Frame G.. / Aluminium G./Aluminium
Vibration solatior Cushy Foot Mounting Cushy Foot Mounting
Fan Cenrifugal Fan-Forward Centrifugal Fan-forward
Curved/Backward Curved Curved/backward Curved
Cooling Media Cellulose Pad Cellulose Pad
Air Discharge Horizontal/vertical Horizontal/vertical
Air Washer Placement Ceiling Suspended/foot Ceiling Suspended/foot
Mounting Mounting
FEATURES SNGLE SKN DOUBLE SKN
2
The Cabinet
Cellulose Pad
Humidin Air Washer made in single skin or double skin cabinets/housings
feature:-
The total assembly is mounted on a horizontal member of heavy galvanized
steel channel with die cast Aluminum Corners for joining them together
with lifting holes on all corners.
We have special software to design the panels for standard Air Washers, to
suit the site conditions for easy assembly.
The Panels are fixed to the rugged frame work made of aluminum section /
G.. Section with special imported fasteners / nut surts. The cabinet is
airtight using self adhesive tapes and gaskets.
Humidin Air Washers have proper accessibility for regular maintenance
through hinged service doors.
The Cellulose pads are of imported origin of make and are designed
for maximum saturation efficiencies, being having large Air to surface
contact area in 7mm flute size and 45 x 45 flute angle (more details are
available further in this catalogue).
Base
The Panels
nspection Windows / Doors
Vapur+
Filters
The standard pre-filters are made of G.. / Aluminium construction
having efficiency 90% down to 70 micron. Depends on application the
fine filters of various efficiencies also can be provided.

Main components which makes air cooling/ air washer most efficient
among other competitors/manufacturers
3
Water Tank
Pipes & Pipe fittings
The Fan Motor & Drive set
Acessories
The water tank is made of mild steel (MS) or stainless steel (SS) with anti corrosive
coatings (FRP/EPOXY) and are designed for easy access for periodic cleaning.
The pipe and other fittings like gate valve, Y-stainers, float valve are of reputed make or
of imported origin.
Humidin offers fan in forward and backward curved design, statically and dynamically
balanced with low noise levels and high efficiency from 300mm dia to 2000mm dia.
The fans are tested as per AMCA.
The fan & motors are mounted on Aluminium section / G.. fabricated slide rails with
provision of easy belt tensioning. The complete assembly is mounted on spring/rubber
vibration isolators for smooth performance.
The fan is connected to the main casing, using fire and moisture resistant flexible
canvassconnection, ensuring low operating noise and vibration.
The drive pulleys are taper bushed duly balanced with proper sized'v' belts.
Humidin air washer features can be enhanced by using various optional accessories as
per below:-
? ntake louver with bird screen.
? Fan outlet dampers.
? Fine filter with extra strached cabinet.
? Drift Eliminators in PVC/ALUMNUM/G..
? Micro processor based control panel with sensors.
? The safety switches and indicators
4
Technical Performance / Selection Chart-Single Blower
Technical details of pad type air washer with single blower

All dimensions are in mm


5
Technical Performance / Selection Chart-Double Blower
6
Fans are manufactured out of best material and are designed and made by our qualified experienced team of
engineer.
The Fans are of international standards and are tested as per AMCA.
The Fans are duly static & dynamic balanced.
The new fan selection software makes it easy to select the fan [You may ask a copy of CD].
The fans are having dully grinded shaft and international standard Pillow/Plumber Block, Ball Bearings for smooth
functioning.
The fans are available in all orientations , clock wise & anti clock wise.
Sizesavailable - from 300mm dia to 1000mm dia.
Air Qty - 1000 CFM to 40000 CFM
Static Pressure - 10mm WG to 100mm WG
Sizes available-from 400mm dia to 1400mm dia.
Air Qty - 2000 CFM to 80000 CFM
Static Pressure - 10mm WG to 200mm WG
Centrifugal Blower Backward Curved ACBC Series Centrifugal Blower Forward Curved ACFC Series

Humidin manufactures its own centrifugal blower in Forward Curved as well


as in Backward Curved designs in their state of the art new production facility
at Tronica City, U.P. ndia, wth most modern CNC machines.
7
Water Distribution Pad
The distribution pad has a special angle
arrangement to disperse the water and thus
ensure a uniform supply of water on the
cooling pads. n this way, the risk of dry spots
that may occur in case of an uneven water flow
is eliminated. A distribution pad is always
advised. The distribution pad has to be ordered
by itself and is available in standard heights
and depths. the standard with is 600mm.
CooIing Pad
Cooling pad is available in
standard heights and
depths. The standard width
is 600mm.
HUMDN AR WASHERS ARE DESGNED WTH THE BEST QUANLTY EVAPORATVE COOLNG PADS, which are of
imported origin of make. The Cooling pad is made of Cellulose (Pulp) sheet and bonded together in 7mm flute size in
45 x 45 Angle.
The Cellulose pad is cross corrugated coated with anti rot, rigidifying and wetting resins.
The Pads are made for maximum efficiency, at minimum pressure drop.
VAPUR +
VAPUR+
P
s
u
r

o
D
p
r
e
s
e
r


G
(
P
U
+
m
W
m
V

A
R
)
6
0.5 1
Velocity in m/s
2 3 4 5
7
8
9
10
1
0
0
1
5
0
2
0
0
0 3
0mm
- 0
Velocity in m/s
200
150
100
50
40
30
20
10
5
1 2 3 4 5 0.5
1
0
0 1
05
2
0
0
0
-
3
0
m
0
m
E
f
f
i
c
i
e
n
c
y

C
u
r
v
e
%

(
V
A
P
U
R
+
)
CELLULOSE COOLNG PAD
To get 300 mm depth (200mm + 100mm)
STANDARD SZES
VAPUR+
PRODUCT SPECIFICATION PERFORMANCE CURVES
1
8
A.C. HUMIDIN AIR SYSTEMS
PLOT NO: B-6, SECTOR: A-3 UPSDC, TRONCA CTY, LON- 201102 U.P. NDA
PH. 0120-2696683, 2696684 FAX 0091-120-2696677
Email: info@humidin.com
Website: www.humidin.com
The intention of this brochure is to introduce you to, and acquaint you with the capabilities of the HUMDN organization in the offered product
areas. t will not answer all your immediate questions, and indeed, it will no doubt raise others. We welcome your interest in our products and shall
be very pleased to provide further information.
n accordance with our policy of continual improvement in design, we reserve the right to depart from the details given in this brochure.
GUARANTEE
HUMDN guarantees its products to be free of defects in materials and workmanship for a period of one year from the
date of delivery from the factory, provided motors are properly installed with overload protector. Humidin agrees to
repair or replace defective parts or part to be returned to the factory, all transportation charges prepaid. Humidin does
not guarantee against abrasion, corrosion or erosion. Humidin shall not be held responsible for any charges in
connection with the removal or replacement of alleged defective equipment nor for incidental consequential
damages.

Potrebbero piacerti anche