Comfort conditioning
ndustrial Ventilation Cooling
Pre cooling for DG sets, Compressors,
Gas turbines
Hybrid Air Conditioners
100% fresh air applications
Retrofits to existing AHU's and Chillers
An evaporative cooler produces effective cooling by
combining a natural process water evaporation with
a simple reliable air-moving system. Fresh outside air
is pulled through moist pads, where it is cooled by
evaporation and circulated through a house or building
by a blower.
SUITABLE FOR.
MALLS & SHOPPNG
STAR HOTELS
CALL CENTES
GARMENT UNTS
ENGNEERNG UNTS
NDUSTRAL UNTS.
nnovative
S O L U T O N S
COMPARSON
Evaporative Air CooIing
1. ntroduces 100% fresh air .
2. Windows and doors left open.
3. Keeps the air moist, great for allergy and
asthmatic conditions.
4. Full ventilation exhausts odors, germs.
5. ncreased cooling capacity as outside
temperature rises.
6. 70% Less than the installation costs of air
conditioning.
7. 90% Less than the running costs of air
conditioning.
Air Conditioning
1. Re-cirulates the same stale air .
2. Windows and doors must be shut.
3. Reduces the moisture, which can be bad for
asthma and allergy sufferers.
4. Re-circulated air can contain germs and
airborne contaminants.
5. Reduced efficiency and capacity as outside
temperature rises.
6. Costly nstallation.
7. Higher running costs.
Ambient Dry Bulb
Temperature( C)
PERCENTAGE RELATVE HUMDTY
Evaporative Cooler Temperature Drop Chart
1
Salient Features of Single Skin &
Double Skin Air Washer
Corner Cast ron PVC
Sheet Metal 16 G. G.. 24 G.. - P.P. Sheet Outside
24 G.. G nside
nsulation No nsulation Puf nsulation CFC Free
Base 100mm C Channel 100 mm C Channel
Tank MS / SS MS / SS
Filter Frame G.. / Aluminium G./Aluminium
Vibration solatior Cushy Foot Mounting Cushy Foot Mounting
Fan Cenrifugal Fan-Forward Centrifugal Fan-forward
Curved/Backward Curved Curved/backward Curved
Cooling Media Cellulose Pad Cellulose Pad
Air Discharge Horizontal/vertical Horizontal/vertical
Air Washer Placement Ceiling Suspended/foot Ceiling Suspended/foot
Mounting Mounting
FEATURES SNGLE SKN DOUBLE SKN
2
The Cabinet
Cellulose Pad
Humidin Air Washer made in single skin or double skin cabinets/housings
feature:-
The total assembly is mounted on a horizontal member of heavy galvanized
steel channel with die cast Aluminum Corners for joining them together
with lifting holes on all corners.
We have special software to design the panels for standard Air Washers, to
suit the site conditions for easy assembly.
The Panels are fixed to the rugged frame work made of aluminum section /
G.. Section with special imported fasteners / nut surts. The cabinet is
airtight using self adhesive tapes and gaskets.
Humidin Air Washers have proper accessibility for regular maintenance
through hinged service doors.
The Cellulose pads are of imported origin of make and are designed
for maximum saturation efficiencies, being having large Air to surface
contact area in 7mm flute size and 45 x 45 flute angle (more details are
available further in this catalogue).
Base
The Panels
nspection Windows / Doors
Vapur+
Filters
The standard pre-filters are made of G.. / Aluminium construction
having efficiency 90% down to 70 micron. Depends on application the
fine filters of various efficiencies also can be provided.
Main components which makes air cooling/ air washer most efficient
among other competitors/manufacturers
3
Water Tank
Pipes & Pipe fittings
The Fan Motor & Drive set
Acessories
The water tank is made of mild steel (MS) or stainless steel (SS) with anti corrosive
coatings (FRP/EPOXY) and are designed for easy access for periodic cleaning.
The pipe and other fittings like gate valve, Y-stainers, float valve are of reputed make or
of imported origin.
Humidin offers fan in forward and backward curved design, statically and dynamically
balanced with low noise levels and high efficiency from 300mm dia to 2000mm dia.
The fans are tested as per AMCA.
The fan & motors are mounted on Aluminium section / G.. fabricated slide rails with
provision of easy belt tensioning. The complete assembly is mounted on spring/rubber
vibration isolators for smooth performance.
The fan is connected to the main casing, using fire and moisture resistant flexible
canvassconnection, ensuring low operating noise and vibration.
The drive pulleys are taper bushed duly balanced with proper sized'v' belts.
Humidin air washer features can be enhanced by using various optional accessories as
per below:-
? ntake louver with bird screen.
? Fan outlet dampers.
? Fine filter with extra strached cabinet.
? Drift Eliminators in PVC/ALUMNUM/G..
? Micro processor based control panel with sensors.
? The safety switches and indicators
4
Technical Performance / Selection Chart-Single Blower
Technical details of pad type air washer with single blower