Sei sulla pagina 1di 36

STANDARD TECHNICAL DETAILS

CONTENTS PAGE
QL-TD-01 Quinn Lite Foundation Blocks (solid floor) 1
QL-TD-02 Quinn Lite Foundation Blocks (suspended floor) 2
QL-TD-03 Quinn Lite Foundation Blocks (stone cladding built off) 3
QL-TD-04 Cavity Wall Cill Detail 4
QL-TD-05 Cavity Wall Window Reveal Detail 5
QL-TD-06 Cavity Wall Lintel Detail (steel) 6
QL-TD-07 Cavity Wall Lintel Detail (concrete) 7
QL-TD-08 Hollowcore Slabs 8
QL-TD-09 Joist Hangers 9
QL-TD-010 Cavity Wall Eaves Detail 10
QL-TD-011 Flat Roof Abutment 11
QL-TD-012 Mono-Pitch Roof Abutment 12
QL-TD-013 Solid Wall Cill Detail 13
QL-TD-014 Solid Wall Window Reveal Detail 14
QL-TD-015 Solid Wall Lintel Detail (concrete) 15
QL-TD-016 Solid Wall Lintel Detail (Steel) 16
QL-TD-017 Solid Wall Eaves Detail 17
QL-TD-018 Movement Joints at Intersecting Walls (butt-jointed) 18
QL-TD-019 Movement Joints at Intersecting Walls (built-in) 19
QL-TD-020 Bed Joint Reinforcement 20
QL-TD-021 Movement Joint in Wall Panels 21
QL-TD-022 Party Wall Construction 22
QL-TD-023 Party Wall Construction with Flexible Cavity Closer 23
QL-TD-024 Quinn Lite Coursing Units 24
QL-TD-025 Concrete Padstones 25
QL-TD-026 Dry Plastering System 26
QL-TD-027-01 Cavity Wall Achieving U-Value 0.20W/m2K 27
QL-TD-027-02 Cavity Wall Achieving U-Value 0.20W/m2K 28
QL-TD-027-03 Cavity Wall Achieving U-Value 0.20W/m2K 29
QL-TD-027-04 Cavity Wall Achieving U-Value 0.24W/m2K 30
QL-TD-027-05 Cavity Wall Achieving U-Value 0.18W/m2K 31
QL-TD-027-06 Solid Wall Achieving U-Value 0.24W/m2K 32
QL-TD-027-07 Solid Wall Achieving U-Value 0.20W/m2K 33
QUINN-lite Standard Technical Details 1
QUINN-lite Standard Technical Details 2
QUINN-lite Standard Technical Details 3
QUINN-lite Standard Technical Details 4
QUINN-lite Standard Technical Details 5
QUINN-lite Standard Technical Details 6
QUINN-lite Standard Technical Details 7
QUINN-lite Standard Technical Details 8
QUINN-lite Standard Technical Details 9
QUINN-lite Standard Technical Details 10
QUINN-lite Standard Technical Details 11
QUINN-lite Standard Technical Details 12
QUINN-lite Standard Technical Details 13
QUINN-lite Standard Technical Details 14
QUINN-lite Standard Technical Details 15
QUINN-lite Standard Technical Details 16
QUINN-lite Standard Technical Details 17
QUINN-lite Standard Technical Details 18
QUINN-lite Standard Technical Details 19
QUINN-lite Standard Technical Details 20
QUINN-lite Standard Technical Details 21
Standard Technical Details QUINN-lite 22
QUINN-lite Standard Technical Details 23
QUINN-lite Standard Technical Details 24
Standard Technical Details QUINN-lite 25
QUINN-lite Standard Technical Details 26
QUINN-lite Standard Technical Details 27
QUINN-lite Standard Technical Details 28
QUINN-lite Standard Technical Details 29
QUINN-lite Standard Technical Details 30
Standard Technical Details QUINN-lite 31
QUINN-lite Standard Technical Details 32
Standard Technical Details QUINN-lite 33
QUINN GROUP
Derrylin, County Fermanagh,
Northern Ireland, BT92 9AU.
t: +44 (0) 28 6774 8866
f: +44 (0) 28 6774 8800
e: info@quinn-group.com
w: www.quinn-group.com
While every care has been taken to ensure the accuracy of the information in this brochure,
Quinn Group can accept no responsibility for any errors which may occur.
CEMENT
PRESTRESSED
QUINN THERM (PIR)
QUINN LITE PAC
AERATED THERMAL BLOCKS
TARMAC
CONCRETE ROOFTILES
RADIATORS
GLASS
PROPERTY
HOTELS
FINANCIAL SERVICES
ENERGY
QUARRY
PLASTICS
PACKAGING
For Further information:
QUINN-lite
Derrylin
Co. Fermanagh
BT92 9AU
Tel: +44 (0) 28 6774 8866
Fax: +44 (0) 28 6774 2309
Email: info@quinn-lite.com
Web: www.quinn-group.com

Quinn-Lite Aircrete Blocks: B3, B5 & B7