Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Ano 2010
PEDRO DANIEL
FERNANDES
HENRIQUES
PEDRO DANIEL
FERNANDES
HENRIQUES
o jri
presidente
agradecimentos
palavras-chave
resumo
keywords
abstract
This thesis results from a research work, aimed at increasing the knowledge of
the structural application of glass in construction.
Currently, the glass is seen as synonymous of light, beauty and transparency.
These features, when combined with the properties of thermal and acoustic
insulation, anti-shock and fire behaviour, contribute to the fascination that
mankind has always had on this subject. Glass is a traditional building material,
where designers can find many possibilities for realization of their projects,
hardly achievable with other materials.
In recent decades, there has been a significant growth in the glass sector,
largely due to the development of new solutions, innovative technologies of
production and the increasing complexity associated with existing works.
This work, through the various chapters, aims to contribute to a better
understanding of the properties of this material, methods of design,
connections and fire performance of glass.
Finally, we present a study on the influence of the breaking of glass in global
temperature of a fire compartment. It used the OZone program, based on the
concept of natural fire safety as an aid in this study.
ndice
ndice de texto
NDICE DE TEXTO
NDICE
NDICE DE TEXTO
XIX
NDICE DE FIGURAS
XXIII
NDICE DE TABELAS
XXVII
LISTA DE SMBOLOS
XXIX
CAPTULO 1 INTRODUO
1.1 CONSIDERAES GERAIS
1.2 OBJECTIVOS
CAPTULO 2 MATERIAL
2.1 CONSIDERAES INICIAIS
11
12
13
13
15
16
18
18
18
22
25
29
30
30
Pgina | xix
32
33
34
43
44
44
46
48
54
55
56
59
60
61
62
63
68
69
70
71
71
72
72
73
74
Pgina | xx
ndice de texto
83
84
86
88
88
90
92
6.4.4 Resultados
94
103
104
106
REFERNCIAS BIBLIOGRFICAS
107
ANEXOS
115
Pgina | xxi
ndice de figuras
NDICE DE FIGURAS
CAPTULO 1 INTRODUO
Figura 1.1 Uso tradicional do vidro [1].
CAPTULO 2 MATERIAL
Figura 2.1 Representao esquemtica do grfico tenso-deformao para o vidro e ao
12
Figura 2.2 Processo de produo do vidro floa [12].
16
Figura 2.3 Tipos bsicos de unidades de vidro: a) vidro monoltico; b) unidade de vidro
isolante; c) vidro laminado; d) vidro resistente ao fogo (adaptado de [13]).
Figura 2.4 O princpio da tmpera do vidro [7].
17
19
Figura 2.5 Fractura padro para diferentes tipos de vidro: a) vidro recozido; b) vidro
termo-endurecido; c) vidro temperado termicamente [7].
20
21
21
Figura 2.8 Comportamento ps-rotura do vidro laminado composto por diferentes tipos
de vidro (adaptado de [7]).
23
Figura 2.9 Desempenho ps-rotura do vidro laminado com PVB e SentryGlas [16].
24
25
25
43
Figura 4.2 Suporte linear tpico do vidro com juntas de EPDM e placas de presso [13].
45
Figura 4.3 Tpica conexo de baixa frico [13].
46
Pgina | xxiii
Figura 4.4 Tpicas conexes aderentes por atrito: vidro monoltico e laminado [13].
47
Figura 4.5 Exemplo de ligao atravs de parafuso: vidro monoltico e laminado [13]. 51
Figura 4.6 Exemplo de um painel de vidro com suporte pontual e as suas condies de
apoio subestrutura [13].
52
Figura 4.7 Grfico de projecto para painis de vidro vertical com suporte pontual, Wk =
0.6MPa [13].
53
Figura 4.8 Grfico de projecto para painis de vidro vertical com suporte pontual, Wk =
1.0MPa [13].
54
Figura 4.9 Grfico de projecto para painis de vidro suspenso/horizontal com suporte
pontual [13].
54
60
Figura 5.2 Noo das trs principais classificaes de resistncia ao fogo (adaptado de
[30]).
65
Figura 5.3 Critrios de desempenho para elementos com funo de suporte, sem
estanquidade e isolamento em situao de incndio.
66
67
68
70
71
74
75
76
Pgina | xxiv
77
ndice de figuras
85
89
90
Figura 6.4 Menu do programa OZone v2.2 para definio da densidade de carga de
incndio.
91
Figura 6.5 Menu do programa OZone v2.2 para definio da variao gradual da quebra
do vidro
93
93
94
96
97
98
98
99
Pgina | xxv
ndice de tabelas
NDICE DE TABELAS
CAPTULO 2 MATERIAL
Tabela 2.1 Composio qumica do vidro [7].
11
13
13
Tabela 2.4 Valores mdios para o mdulo de elasticidade (E), resistncia traco () e
deformao de rotura (f) [5].
15
15
23
31
Tabela 3.2 Tenses admissveis recomendadas pela Pilkington para o projecto inicial
[13].
32
33
33
34
36
63
64
Pgina | xxvii
64
65
Tabela 5.7 Desempenho de vrios tipos de vidro laminado, segundo Mejicosky [39]. 78
87
89
Tabela 6.3 Valores caractersticos da densidade de carga de incndio qf,k por unidade
de rea do pavimento de acordo com o tipo de ocupao [30].
91
96
ANEXOS
Tabela A1.1 Resumo das normas Europeias para produtos bsicos de vidro [7].
A.1
Tabela A1.2 Resumo das normas Europeias para produtos processados de vidro [7]. A.2
Tabela C1.1 Factores parciais M e V [24]
C.2
C.2
Tabela G1.1 Factor do tipo de vidro (GTF) para um nico painel de vidro monoltico ou
laminado
G.1
G.2
Pgina | xxviii
Lista de smbolos
LISTA DE SMBOLOS
A
A t
Risco de falha
Calor especfico
c1
c2
c3
c4
Cargas permanentes
Mdulo de Young
Ed
fA
fb,k
fg,d
fg,k
fk
fmt;u;d
fp
ft
Resistncia traco
ftS
Mdulo de rigidez
GTF
Ga
kA
kb
Pgina | xxix
ke
KI
KIc
kmod
ambientais
LR
Carga resistente
NFL
Pf
Probabilidade de falha
Qx
Q ,
Fluxo de calor
qf,k
Rd
Rref
Tempo
TA
TF
(q,v)
D,L ,Q e T
Factores parciais
(Ared)
(Sv)
adm
bB,Atest,k
duplo R400
eff,d
eq,max(q,x,y)
Pgina | xxx
Lista de smbolos
max,d
mt;u;d
Tenso de projecto
1(x,y)
V,k
(t)
Massa volmica
Alongamento de rotura
Coeficiente de Poisson
Condutividade trmica
Factor de importncia
M,E
M,V
Pgina | xxxi
Captulo 1
Introduo
CAPTULO 1 INTRODUO
1.1 CONSIDERAES GERAIS
1.2 OBJECTIVOS
Pgina | 2
Captulo 1. Introduo
1. INTRODUO
Neste captulo feita uma introduo geral ao trabalho desenvolvido. So descritos os
principais objectivos e os meios para os atingir, bem como, a apresentao da estrutura da
presente dissertao.
Pgina | 3
Com esta evoluo, o tamanho dos painis de vidro usados aumentou e o mtodo de
conexo tornou-se mais complicado (Figura 1.2), sendo as aces a que o vidro se encontra
sujeito, praticamente as mesmas.
De acordo com a Revista SIM [2], o uso do vidro na construo civil encontra-se em
crescimento desde meados de 1980. A tecnologia de produo e beneficiamento do vidro
plano tem possibilitado maior garantia de segurana, controle acstico e sobretudo, maior
economia de energia, iluminao e temperatura, aos mais arrojados projectos. Actualmente
o vidro j uma tendncia em obras de arquitectura e engenharia (Figura 1.3). S esse
material permite uma relao de espao entre os meios interno e externo, ampliando a
visibilidade e a segurana [3].
Pgina | 4
Captulo 1. Introduo
1.2 Objectivos
Esta dissertao pretende fazer um levantamento da regulamentao disponvel e iniciar na
Universidade de Aveiro uma linha de investigao relativa ao comportamento ao fogo do
Pgina | 5
vidro estrutural. O objectivo geral foi alcanado atravs dos seguintes objectivos
especficos:
Pgina | 6
Captulo 1. Introduo
Captulo 1
Introduo
Captulo 3
Orientaes e mtodos de
dimensionamento do vidro
estrutural
Captulo 2
Material
Captulo 4
Conexes do vidro
estrutural
Captulo 5
Comportamento do vidro estrutural em caso de
incndio
Captulo 6
Influncia da quebra do vidro na temperatura
de um compartimento de incndio
Captulo 7
Consideraes finais e
desenvolvimentos futuros
Pgina | 7
Captulo 2
Material
CAPTULO 2 MATERIAL
2.1 CONSIDERAES INICIAIS
11
12
13
13
15
16
18
18
18
22
25
Pgina | 10
Captulo 2. Material
2. MATERIAL
Neste captulo feita uma introduo ao material vidro, enumerando as suas principais
propriedades, o processo de fabrico, alguns tipos de vidro e referncia ao tipo de vidro
usado em elementos estruturais.
Vidro borossilicato
Areia de slica
SiO2
69% 74%
70% 87%
Cal
CaO
5% 14%
xido de sdio
Na2O
10% 16%
0% 8%
Trixido de boro
B2O3
7% 15
xido de potssio
K 2O
0% 8%
Magnesia
MgO
0% 6%
Alumina
Al2O3
0% 6%
0% 8%
0% 5%
0% 8%
Outros
Pgina | 11
vidro borossilicato comea a amolecer a cerca dos 821C e o vidro silicato sodo-clcico
(vidro mais comum na construo) a 550C [8].
O vidro um material frgil com um comportamento mecnico linear perfeitamente
elstico, nunca apresentando, portanto, deformao permanente (Figura 2.1). A resistncia
terica do vidro determinada pela energia necessria para quebrar as ligaes qumicas
entre os seus constituintes. Porm, a tenso necessria para fracturar o vidro menor do
que a esperada quando se consideram as foras necessrias para romper aquelas ligaes
inter atmicas [4].
Pgina | 12
Captulo 2. Material
Massa volmica
Dureza
Resistncia abraso
Elasticidade
E = 26 33 GPa [11]
Coeficiente de Poisson, :
Resistncia traco
compresso
Resistncia flexo
Pgina | 13
ordem de:
Pgina | 14
Captulo 2. Material
Tabela 2.4 Valores mdios para o mdulo de elasticidade (E), resistncia traco () e deformao
de rotura (f) [5].
Espesura
(mm)
(GPa)
(MPa)
60.12
83.57
0.12
60.70
52.56
0.08
10
57.58
79.57
0.05
19
48.44
18.28
0.03
57.36
181.78
0.27
57.04
198.95
0.20
10
63.97
229.35
0.13
19
54.97
181.82
0.07
3.1.3
183.01
114.36
0.057
5.1.5
167.77
105.94
0.038
8.1.8
125.75
102.79
0.031
10.1.10
116.86
88.79
0.025
12.1.12
102.38
84.48
0.021
Float
Temperado
Laminado
Calor especfico
Pgina | 15
Pgina | 16
Captulo 2. Material
aplicao de revestimentos;
Uma viso geral das normas Europeias pertinentes para os produtos de vidro dada
no Anexo A.
As seces que se seguem fornecem informaes detalhadas sobre os produtos de
vidro e mtodos mais importantes de processamento de uso na construo civil. O vidro
temperado e o vidro laminado so os que oferecem maior resistncia,
resistncia, como vai ser possvel
constatar mais frente, tendo dessa forma maior aplicabilidade estrutural. Devido a esse
Pgina | 17
facto, tomado especial nfase na descrio que se segue em detrimento dos outros tipos
de vidro.
Pgina | 18
Captulo 2. Material
Segundo Haldimann, Luible & Overend [13], a fractura padro uma funo da
energia armazenada no vidro, ou seja, da tenso residual e da tenso devido s cargas. A
Figura 2.5 mostra a fractura padro de espcimes quando carregados no teste do anel
coaxial duplo. O vidro temperado termicamente apresenta um maior nvel de tenses
residuais e geralmente quebra em pequenos
pequenos fragmentos com cerca de 1cm2. Este tipo de
fractura totalmente caracterstica do vidro temperado, sendo por isso tambm
denominado de vidro de segurana.
segurana No entanto, e de acordo com os mesmo autores, esse
termo pode ser enganador, pois os fragmentos
fragmentos mesmo que pequenos ao cair de uma altura
considervel, podem
m causar ferimentos graves. Embora o vidro temperado termicamente
seja, de todos os tipos de vidro, o que apresenta maior capacidade estrutural,
estrutural o seu
desempenho ps-rotura pobre devido aos seus
seus pequenos fragmentos. Dessa forma, surge
vidro termo-endurecido
endurecido que pretende estabelecer uma afinidade entre um bom desempenho
estrutural e uma suficiente grande fragmentao, permitindo um modelo para uma boa
performance ps-rotura.
Pgina | 19
a) Vidro recozido
b) Vidro termo-endurecido
c) Vidro temperado
termicamente
Figura 2.5 Fractura padro para diferentes tipos de vidro: a) vidro recozido; b) vidro termoendurecido; c) vidro temperado termicamente [7].
Pgina | 20
Captulo 2. Material
Segundo Haldiman [7], a tenso residual superficial tpica de compresso varia entre
80MPa e 150MPa para o vidro temperado termicamente. Na norma Americana ASTM C
1048-04 necessrio ter uma tenso de compresso superficial mnima de 69MPa ou uma
compresso na borda no inferior a 67 MPa. Nas normas Europeias EN 12150-1:2000 e
EN 12150-2:2004 contabilizada a fragmentao, o tamanho mximo de fragmentos e
resistncia mnima de fractura em quatro pontos ensaiados flexo. Os parmetros mais
importantes do processo de tmpera so: a espessura do vidro, o coeficiente de dilatao
trmica do vidro e do coeficiente de transferncia de calor entre o vidro e o ar.
Pgina | 21
Pgina | 22
Captulo 2. Material
Para Haldimann [7]], o material mais comum usado nas intercalares de vidro
laminado o polivinil butiral (PVB). O PVB um material que bloqueia quase na
totalidade a radiao UV, sendo por isso, as folhas de PVB denominadas de pelculas de
proteco UV. A espessura nominal de uma nica folha de PVB 0.38 milmetros.
Normalmente, uma intercalar de PVB composta
composta por duas (0.76mm) ou quatro (1.52mm)
folhas de PVB. O PVB um material viscoelstico, isto , as suas propriedades fsicas
dependem sobretudo da temperatura e da durao da carga. temperatura ambiente, o
PVB um material relativamente macio, com um alongamento na rotura acima de 200%.
A temperaturas inferiores a 0C e para tempos de carga curtos, no geral, o PVB capaz de
transferir tenses de corte. Quando sujeito a temperaturas elevadas e longos tempos de
carga, a transferncia dee tenses de corte reduzida. A Tabela 2.6 apresenta as
propriedades tpicas do PVB.
Tabela 2.6 Propriedades tpicas do material PVB [13].
Massa volmica ()
Alongamento de rotura (
)
1070
0-4
0.50
80x10-6
Kg/m3
GPa
K-1
20
MPa
300
Pgina | 23
Figura 2.9 Desempenho ps-rotura do vidro laminado com PVB e SentryGlas [16].
Empresa multinacional sediada nos USA, dedicada fundamentalmente a vrios ramos industriais da
qumica. amplamente conhecida pela sua grande variedade de produtos, assim como pela sua liderana no
campo da pesquisa em cincia e tecnologia.
Pgina | 24
Captulo 2. Material
Pgina | 25
Captulo 3
Orientaes e mtodos de dimensionamento
do vidro estrutural
29
30
30
32
33
Pgina | 28
34
Pgina | 29
em tenses admissveis quer o em estados limites ltimos. Porm, devido esbelteza dos
elementos, deve ser considerado sempre os efeitos de encurvadura [11].
Encontra-se para alm do escopo desta dissertao dar uma panormica exaustiva de
todas as normas nacionais e mtodos de dimensionamento existentes no campo do vidro,
uma vez que, para alm de diversos factores, muitos deles so baseados em teorias simples
e desse modo no devem ser aplicveis a clculo de vidro estrutural. As normas e mtodos
de dimensionamento que se seguem so os mais amplamente utilizados e por esse motivo
so de especial interesse para o dimensionamento do vidro estrutural.
Pgina | 30
(3.1)
tenso mxima no plano principal, calculada com base nos valores caractersticos das
aces de projecto, no cenrio mais desfavorvel;
Vidro recozido
Vidro temperado
termicamente
Vidro laminado
Envidraados verticais
Envidraados
suspensos/horizontais
18
12
50
50
22.5
12 (25*)
Pgina | 31
* Apenas para o painel de vidro inferior no caso de cenrio de perigo "painel superior
fracturado.
A Tabela 3.2 mostra as tenses admissveis recomendadas pela Pilkington para o
projecto inicial. Estes valores s devem ser usados em conjunto com a anlise linear de
tenses.
As tenses admissveis baseadas em mtodos de projecto apresentam as seguintes
desvantagens notveis:
Tabela 3.2 Tenses admissveis recomendadas pela Pilkington para o projecto inicial [13].
Tipo de carga
Curto prazo
(tenso no corpo da placa)
Curto prazo
(tenso no bordo da placa)
Vidro temperado
Exemplo de
Vidro recozido
carregamento
(MPa)
Vento
28*
59
Vento
17.8*
59
Neve
10.75
22.7
Pavimentos
8.4
35
35
termicamente
(MPa)
Mdio prazo
Longo prazo
* Vlido para vidro recozido 10mm. Para vidro de 6mm de espessura, estes valores
devem ser multiplicados por um factor de 1.4.
Pgina | 32
Para projecto inicial de envidraados com apoio lateral contnuo ao longo de dois ou quatro
bordos, Colvin [19] prope uma lista de relaes mximas de vo/espessura, representadas
na Tabela 3.3.
Tabela 3.3 Vos mximos suportados, segundo Colvin [19].
Tipo de vidro
Vertical
Inclinado/horizontal
Vidro recozido
150
100
200
150
150
100
150
100
Espessura
(mm)
Peso
(Kg/m2)
3*
5*
8*
10
12
15
19
25
7.5
10.0
12.5
15.0
20.0
25.0
30.0
37.5
47.5
62.5
Pgina | 33
Vidro temperado
Os tamanhos das folhas de vidro temperado so geralmente menores que o tamanho do
vidro float disponveis. O vidro temperado de 25 mm ainda em fase experimental e por isso
encontra-se na generalidade indisponvel.
Tabela 3.5 Espessuras e tamanho de folha do vidro temperado [20].
Espessura
(mm)
Tamanho
de folha*
(mm x mm)
4
1500
5
2000
6
2000
8
2000
10
12
15
19
2000
2000
1700
1500
Pgina | 34
Pgina | 35
Descrio de parmetros
R400
(DELR)
,
(3.2)
, ,
, . .. .,
+ ,
(q,
, f, (3.3a)
, = x, y dx dy
f, = k ,
+
.
, ,
. (3.3c)
Pgina | 36
;; f;; (3.4a)
f;; =
(3.4b)
pr-esforado
kb coef. de comportamento de fractura
ke coef. para o tratamento de bordo
kmod factor modificao para perodo de
carregamento.
m factor parcial para a fora inerente
V factor parcial de tenses residuais
Ed valor de clculo das aces
Rd valor de clculo resistente
(3.5b)
carregamento
m factor parcial para a fora inerente, omitido
para vidro pr-esforado.
max,d tenso mxima de projecto no plano
principal
k resistncia caracterstica inerente rotura por
Shen
superficial
Siebert
Pgina | 37
(3.7a)
,, = , + (3.7b)
= ln
(3.7c)
B = k cx, y, q, x, y dA
(3.8b)
relevantes
e
parmetros de falha de superfcie
D cargas permanentes
12.20
factor de importncia
E R (3.10a)
= + . . + +
(3.10b)
R = c . c. c . c . R (3.10c)
Pgina | 38
K = Y. a (3.11b)
K K (3.11a)
Pgina | 39
Pgina | 40
Captulo 4
Conexes do vidro estrutural
43
44
44
46
48
54
55
56
Pgina | 42
Figura 4.1 Resumo dos tipos de conexo de vidro mais comuns [13].
Pgina | 43
Pgina | 44
dois ou quatro bordos. O peso prprio do vidro transferido para o caixilho atravs de
calos de plstico localizados na borda horizontal do vidro. Em alternativa, o peso prprio
pode ser transmitido atravs de camadas de neopreno com dureza entre 60 e 80 (teste
Shore A).
As cargas laterais, normalmente resultantes da presso do vento e da suco, podem
ser travadas mecanicamente por intermdio da fixao do vidro entre o sistema de armao
de um lado e um acessrio convexo de fixao (placa de presso/nivelamento) do outro
lado. As cargas so transferidas a partir do vidro para o sistema de fixao atravs de 6 a
15mm de neopreno, juntas de borracha etileno-propileno-dieno (EPDM) ou de silicone
(Figura 4.2). Estes apoios permitem um bom grau de rotao da borda de vidro e podem,
portanto, ser considerados como suportes simples para fins de modelao analtica e
numrica [13].
Figura 4.2 Suporte linear tpico do vidro com juntas de EPDM e placas de presso [13].
Pgina | 45
Pgina | 46
atrito so, teoricamente, mais adequados para a introduo de cargas de traco no plano,
uma vez que, distribuem melhor a carga sobre a superfcie e evitam a concentrao de
tenses principais. Normalmente, o conjunto composto por: painel de vidro, chapas de
ao em ambos os lados, vedantes entre as chapas de ao e do vidro e parafusos de fixao.
O contacto directo entre o vidro e as peas de ao evitado, por ter furos para parafusos de
grandes dimenses e pela aplicao de vedantes que actuam como um material de camada
intermediria entre o vidro e as placas de ao (Figura 4.4). O vedante deve ser forte o
suficiente para suportar as tenses normais induzidas pelos parafusos pr-esforados sem
deslizamento, devendo resistir tambm s tenses de corte induzidas pela fora no mesmo
plano. Ao mesmo tempo, no deve ser muito duro, de forma a no danificar o vidro,
suficientemente flexvel para permitir tolerncias de fabricao entre o vidro e as placas de
ao e deve apresentar fluncia muito baixa para evitar a diminuio das foras normais dos
parafusos com o passar do tempo. Os materiais tpicos usados so o alumnio puro ou
juntas de fibras, tendo na ordem de 1mm de espessura.
Figura 4.4 Tpicas conexes aderentes por atrito: vidro monoltico e laminado [13].
Pgina | 47
Cuidados especiais devem ser tomados, quando ligaes aderentes deste tipo so
planeadas para o vidro laminado de segurana. Os materiais intercalados no vidro
laminado de segurana, como o polivinil butiral (PVB), so incapazes de resistir s foras
de presso induzidas pela conexo sem deslizar para fora, sofrendo deformaes por
fluncia elevadas que reduzem o pr-esforo ao longo do tempo. Por conseguinte, a
intercalar na regio da ligao de presso muitas vezes removida e substituda por um
material mais rgido, no viscoso (por exemplo, ligas de alumnio prximo a alumnio
puro, que tm um baixo mdulo de elasticidade), com a mesma espessura (Figura 4.4).
A fora que pode ser transferida por atrito depende da geometria da conexo, a
rigidez dos materiais envolvidos, o mais baixo coeficiente de atrito entre as vrias
interfaces e da capacidade, a longo prazo, de carga dos vrios componentes [13].
importante referir que, dependendo da geometria do vidro e da localizao do
grampo, estes podem gerar restries rotacionais locais no vidro que, por sua vez, originam
concentraes de tenses nesses locais. A menos que a rotao livre da borda do vidro na
zona da fixao seja alcanada na prtica, atravs da adopo de um material intermedirio
suficientemente espesso e macio, a restrio do grampo deve ser considerada no modelo de
anlise.
Pgina | 48
Pgina | 49
O atrito entre o material da bucha e vidro tem influncia sobre a tenso mxima
principal.
influncia sobre a capacidade de carga dos painis de vidro aparafusado. A tenso mxima
de traco ocorre, na maioria dos casos, perto dos furos. Desta forma, essencial um
modelo de anlise realista detalhado e cuidadoso para o projecto de vidro aparafusado.
A seleco dos materiais e detalhe so outros aspectos fundamentais no projecto de
ligaes aparafusadas em vidro. Tanto quando o vidro est em causa, aconselhvel o uso
do vidro temperado termicamente e do vidro termo-endurecido, uma vez que, a resistncia
do vidro recozido na rea do furo bastante pobre. Alm disso, quando o vidro tratado
termicamente laminado usado, muitas vezes ocorre um desalinhamento na regio do furo,
por conseguinte, prefervel o uso da resina ou argamassa de injeco, de forma a criar
uma distribuio de carga homognea em todas as camadas de vidro (Figura 4.5).
Conexo atravs de parafuso
A conexo atravs de parafuso, o tipo de ligao mais antiga e geralmente mais forte,
onde a conexo submetida a uma tenso no plano (compresso). Este tipo de conexo
oriundo directamente da construo de ao e madeira e particularmente til no vidro,
uma vez que, pode dar continuidade estrutural entre elementos separados de vidro (por
exemplo, emendados de viga, ligao de aletas, etc.), que so limitados em tamanho devido
ao processo de fabrico.
Pgina | 50
Figura 4.5 Exemplo de ligao atravs de parafuso: vidro monoltico e laminado [13].
Suporte pontual
Os suportes pontuais so ligaes aparafusadas utilizados em ligaes de vidro-vidro ou
para ligar o vidro a um subsistema sem criar uma articulao de meia-volta (fixaes
atravessadas), como os fixadores referenciados em 4.2.2. A remoo dessa meia-volta
reduz o impacto visual da ligao, para alm deste tipo de ligao ter evoludo ainda a este
respeito, pela possibilidade de utilizao de um parafuso de cabea escareada que elimina
todas as salincias para alm da superfcie de vidro.
Os tpicos suportes pontuais no so adequados para a transferncia de elevadas
cargas no plano para o painel de vidro, com excepo do peso prprio do vidro, em caso de
Pgina | 51
Figura 4.6 Exemplo de um painel de vidro com suporte pontual e as suas condies de apoio
subestrutura [13].
A geometria do furo, ou seja, furos cilndricos para fixao pontual com discos de
ao em cada superfcie de vidro ou furos cnicos para suporte pontual com
parafusos de cabea escareada.
Pgina | 52
Figura 4.7 Grfico de projecto para painis de vidro vertical com suporte pontual, Wk = 0.6MPa [13].
Pgina | 53
Figura 4.8 Grfico de projecto para painis de vidro vertical com suporte pontual, Wk = 1.0MPa [13].
Figura 4.9 Grfico de projecto para painis de vidro suspenso/horizontal com suporte pontual [13].
Pgina | 54
ligaes adesivas rgidas (ou seja, adesivos acrlicos, adesivos epoxi e resina de
polister).
Pgina | 55
Pgina | 56
Captulo 5
Comportamento do vidro estrutural em caso
de incndio
59
60
61
62
63
68
69
70
71
71
72
72
73
74
Pgina | 58
Pgina | 59
1200
Temperatura (C)
1000
800
600
400
200
0
0
10
20
30
40
50
60
70
80
90
Tempo (min.)
Pgina | 60
Vila Real [30], esta ser a via que permitir simultneamente tornar a segurana contra
incndio mais racional, mais eficaz e mais econmica, dando abertura utilizao da
Engenharia de segurana contra incndio, ver seco 5.2.1.
A segurana contra incndios de edifcios tem vindo a merecer em Portugal uma
ateno crescente, comeando a surgir no nosso pas regulamentao que abrange os vrios
tipos de edifcios existentes, atribuindo classes de resistncia ao fogo em funo do tipo de
edifcio, da sua altura, nmero de ocupantes e do risco de incndio local,
independentemente dos materiais que constituem a estrutura. Os regulamentos consideram
no s a reaco ao fogo dos materiais, como tambm a resistncia ao fogo dos elementos
estruturais ou de compartimentao. Na rea de resistncia ao fogo, Portugal no se
encontra dotado de qualquer documento normativo. No entanto, o Decreto-Lei n.
220/2008, de 12 de Novembro, que estabelece o Regme Jurdico de Segurana Contra
Incndio em Edifcios, que embora no seja um documento normativo dedicado
estritamente rea de resistncia ao fogo, rene disposies regulamentares de segurana
contra incndio aplicveis em edifcios e recintos.
Pgina | 61
exposio ao fogo e a interaco entre os vrios elementos estruturais [30]. Para Cadorin
[31], numa anlise baseada no desempenho, a primeira etapa do processo estabelecer as
metas de segurana contra incndios, objectivos e critrios de desempenho. Uma vez que,
os critrios de desempenho so estabelecidos, os diferentes clculos podem ser realizados
para determinar se os critrios de desempenho especificados sero atingidos pela
abordagem proposta. Na anlise baseada no desempenho, a avaliao da aco trmica
sobre a estrutura exposta ao fogo, requer a avaliao dinmica dos incndios, que um
grande avano em relao utilizao de curvas de incndio nominais na abordagem
prescritiva.
susceptibilidade a inflamar-se;
entrarem em ignio.
Pgina | 62
RE tt
R tt
Tabela 5.2 Classificao geral para elementos sem funes de suporte de carga [33].
tt o perodo de tempo durante o qual os critrios estanquidade e isolamento
EI tt
so cumpridos.
E tt
Isolamento trmico
Radiao
Pgina | 63
Aco mecnica
Fecho automtico
Passagem de fumo
P ou PH
Resistncia ao fogo
Tabela 5.4 Elementos com funes de suporte de carga e sem funo de compartimentao resistente
ao fogo [34].
Aplicvel a
Paredes, pavimentos, coberturas, vigas, pilares, varandas, escadas, passagens
15
20
30
45
60
90
120
180
240
360
Tabela 5.5 Elementos com funes de suporte de carga e com funo de compartimentao resistente
ao fogo [34].
Aplicvel a
Paredes
RE
20
30
60
90
120
180
240
REW
20
30
60
90
120
180
240
20
30
60
90
120
180
240
60
90
120
180
240
REI
15
REI-M
Aplicvel a
45
30
Pavimentos e coberturas
RE
REI
15
20
30
20
30
45
60
90
120
180
240
60
90
120
180
240
Pgina | 64
15
20
30
45
60
90
120
180
240
360
Pgina | 65
Paredes e pilares
Pavimentos,
coberturas, vigas,
varandas,
passagens e
escadas
a) Contraco axial:
C = h/100 (mm)
b) Taxa de contraco axial:
dC/dt = 3h/1000 (mm/min)
a) Deflexo:
D = L2/400d (mm)
b) Taxa de deflexo:
dD/dt = L2/9000d (mm/min)
Figura 5.3 Critrios de desempenho para elementos com funo de suporte, sem estanquidade e
isolamento em situao de incndio.
Pgina | 66
Pavimentos e
coberturas
Paredes
a) Contraco axial:
C = h/100 (mm)
b) Taxa de contraco axial:
dC/dt = 3h/1000 (mm/min)
h altura inicial (mm)
Estanquidade (E)*
a) Fendas e aberturas de dimenses
considerveis;
b) inflamao do vidro;
c) chamas sustentadas no lado oposto.
Isolamento (I)
Temperatura mdia na face no
exposta < 140 C;
Limite da temperatura mxima em
qualquer ponto de 180 C.
Radiao (W)
Inferior a 15 kW/m2
Figura 5.4 Critrios de desempenho para elementos com funo de suporte, estanquidade e isolamento
em situao de incndio.
Pgina | 67
Pgina | 68
aplicaes correntes, tero que ser necessariamente simplificados, mas sem deixar de
representar de forma adequada a influncia dos parmetros que condicionam
predominantemente o comportamento das estruturas [30].
Actualmente, existem vrias formas de modelar a temperatura dos gases no
compartimento de incndio apresentados pelos regulamentos. O Eurocdigo 1, EN 1991-12, fornece dentro das relaes temperatura-tempo, trs tipos de curvas nominais: a curva
padro, a curva de hidrocarbonetos e a curva de fogo exterior. No que respeita simulao
atravs de modelos simplificados, do incndio estrutural, o mesmo Eurocdigo apresenta
as curvas de incndio paramtricas e as curvas de incndio localizado, tendo sido
apresentadas nesta dissertao apenas as curvas paramtricas.
(5.1)
(5.2)
em que:
(5.3)
Pgina | 69
Temperatura (C)
1000
800
600
Curva de incndio para elementos
exteriores
400
200
Curva de incndio de
hidrocarbonetos
0
0
10
20
30
40
50
60
70
80
90
Tempo (min.)
5.3.2 Curvas
rvas de incndio paramtricas
Segundo Vila Real [30],, as curvas paramtricas temperatura-tempo
temperatura
definidas no Anexo A
da Parte 1.2 do Eurocdigo 1, so tambm curvas de evoluo da temperatura em funo
do tempo, mas contrariamente s curvas nominais, dependem
dependem de certos parmetros fsicos
como os que a seguir se indicam:
Pgina | 70
1200
Temperatura (C)
1000
800
600
400
200
0
0
10
20
30
40
50
60
70
80
90
Tempo (min.)
Pgina | 71
G + , . Q , + , . Q , + A t
(5.4)
onde o factor de segurana parcial das aces permanentes em caso de acidente, que
dever ter o valor unitrio; G o valor caracterstico das aces permanentes; Q, o
Pgina | 72
Pgina | 73
Pgina | 74
Pgina | 75
1200
Temperatura (C)
1000
800
600
400
200
0
0
10
20
30
40
50
60
70
80
90
Tempo (min.)
O vidro temperado, quando comparado com vidro float e o vidro recozido, bastante
menos sensvel s tenses de traco. O processo de tratamento trmico cria uma
distribuio de tenses permanente no vidro, com um aumento da tenso de compresso
nas reas de superfcie. As tenses de traco causadas pela expanso trmica ou por
influncias mecnicas em caso de incndio, leva quebra somente, quando superar essa
tenso inerente compresso na superfcie do vidro. No entanto, este tratamento no
suficiente para obter resistncia ao fogo. Segundo Nolte [38], muito cuidado deve ser dado
tambm ao tratamento dos bordos do vidro, de forma a evitar tenses perigosas perto das
mesmas. Numa aplicao normal, os vidros temperados oferecem a vantagem de poderem
ser executados como vidro de segurana.
O vidro temperado termicamente, quando submetido ao Standard Fire Test,
apresenta-se da seguinte forma: estvel at aos 300350C , sendo vulnervel aos
diferenciais de temperatura nesse patamar; acima de 400C, endurece; e acima de 600C,
que corresponde aproximadamente temperatura de transformao do vidro, amolece e
ocorre a queda do vidro (Figura 5.11).
Pgina | 76
1200
Temperatura (C)
1000
800
600
400
200
0
0
10
20
30
40
50
60
70
80
90
Tempo (min.)
1200
Temperatura (C)
1000
800
600
400
200
0
0
10
20
30
40
50
60
70
80
90
Tempo (min.)
Pgina | 77
Pgina | 78
Pgina | 79
Pgina | 80
Captulo 6
Influncia da quebra do vidro na temperatura
de um compartimento de incndio
83
84
86
88
88
90
92
6.4.4 Resultados
94
Pgina | 82
Pgina | 83
posterior, NRCC analisou vidros usando a exposio ao calor radiante. Sob tais condies,
o vidro simples de espessura no especificada quebra quando o lado exposto atinge
temperaturas na ordem dos 150C 175C, encontrando-se o lado oposto com
temperaturas no intervalo de 75C a 150C. O vidro temperado, para alm de suportar
temperaturas mais elevadas quando comparado com o vidro simples, tambm apresenta
uma taxa de transmisso de calor mais reduzida.
Tendo o vidro temperado elevada aplicabilidade estrutural, devido a diversos factores
j referenciados ao longo desta dissertao, torna-se de especial interesse saber qual a
influncia do incio da sua fissurao (provocada por um incndio) na temperatura de um
compartimento de incndio. A avaliao realizada com recurso ao programa OZone v2.2
[6], que permite o clculo da temperatura do compartimento de incndio, baseado no
conceito de segurana ao fogo natural, EN 1991-1-2.
Antes de iniciar a avaliao da quebra do vidro, importante compreender os
diferentes desenvolvimentos possveis, ou cenrios, de incndio num compartimento e
apontar os parmetros que influenciam o comportamento do fogo (seco 6.2), bem como
o princpio de funcionamento dos modelos trmicos em situao de incndio, mais
concretamente, os modelos de zona onde se encontra englobado o programa OZone v2.2
[6] (seco 6.3).
O fogo uma reaco qumica exotrmica que pode ocorrer quando trs elementos esto
reunidos: combustvel, oxignio e uma fonte de calor. Estes trs elementos so
frequentemente referidos como tringulo do fogo (Figura 6.1). Para existir um incndio e
ser sustentado necessrio:
Pgina | 84
Pgina | 85
Pgina | 86
Curvas temperatura-tempo
nominais (regulamentao
prescritiva)
Curva de hidrocarbonetos
Incndio natural
(regulamentao baseada no
desempenho)
Fogo de compartimento
Fogo localizado
Modelos de zona
Modelos de campo
O OZone v2.2 [6], programa usado no presente captulo, encontra-se englobado nos
modelos de fogo avanado, mais especificamente, nos modelos de zona. A sua aplicao
ao clculo estrutural em situao de incndio restringe-se determinao da temperatura
dos gases nos compartimentos, para que seja possvel determinar, em seguida, a
temperatura nos elementos estruturais e dimensionamento em situao de incndio.
Um modelo de zona um modelo numrico que divide os espaos fsicos em estudo
em diferentes volumes de controlo, ou zonas. Os modelos de zona mais comuns dividem
um compartimento em duas zonas, uma zona superior mais quente e uma inferior mais fria.
Um caso particular dos modelos de zona so os modelos de uma zona. Estes ltimos, so
baseados na hiptese de que existe apenas uma camada uniforme e o compartimento de
incndio pode ser tratado como uma fornalha com propriedades homogneas. Alguns
modelos de zona, como o caso do implementado no programa OZone v2.2[6], incluem a
possibilidade de transitar de um modelo de duas zonas para um modelo de uma zona
quando esto reunidas condies para que tal acontea (quando ocorre o flashover) [42].
Pgina | 87
O propsito deste estudo passa pela avaliao da influncia da quebra do vidro temperado
na temperatura de um determinado compartimento de incndio. Pretende-se comparar
resultados devido modificao de aspectos geomtricos a nvel da compartimentao,
anlise de diferentes densidades de carga de incndio numa determinada rea fixada e
comparao de resultados entre o vidro temperado e o vidro comum. Desta forma, foi
considerado, na totalidade do estudo, um compartimento de incndio com 3m de altura,
composto por uma parede totalmente envidraada, de forma a simular uma fachada de
vidro. Para as restantes paredes, pavimento e tecto considerou-se uma espessura de 0.20m
em beto normal, com condutibilidade trmica de 1.6 W/mK.
Pgina | 88
(m)
(m)
(m)
A1
25
A2
42
A3
56
10
A4
90
11
12
A5
132
Pgina | 89
Pgina | 90
Ocupao
Valor mdio
Quantilho 80%
Habitao
780
948
Hospital (quarto)
230
280
Hotel (quarto)
310
377
Biblioteca
1500
1824
Escritrio
420
511
285
347
Centro comercial
600
730
Teatro (cinema)
300
365
100
122
Pgina | 91
Pgina | 92
a)
b)
Figura 6.6 Esquema da variao gradual da quebra para o vidro: a) temperado e b) comum.
Pgina | 93
6.4.4 Resultados
(i)
compartimento:
A Figura 6.7 mostra a evoluo da temperatura dos gases para reas distintas de
compartimentao. A presente variao referente a compartimentos com densidade de
carga de incndio correspondente a uma habitao e um incio da fissurao a 290C com
10% de aberturas. Verifica-se que a reduo da rea de incndio, traduz-se na evoluo
sbita da temperatura nos instantes iniciais, originando incndios mais longos e mais
severos. Para reas de incndio iguais a 25m2, atingida no compartimento a temperatura
de amolecimento do vidro temperado, ocorrendo a sua queda e diminuio brusca da
temperatura dos gases. A criao de uma massa de ar com densidade mais baixa devido ao
aquecimento na zona do fogo, ao ascender , sai parcialmente pela zona superior da fachada
anteriormente envidraada, com a simultnea entrada de ar frio pela zona inferior. Este
facto, leva diminuio brusca da temperatura do compartimento. Nos restantes casos, o
incndio passa pelas suas diferentes fases sem atingir a temperatura de amolecimento do
vidro temperado.
700
Colapso
do vidro
Temperatura (C)
600
500
A = 25 m2
400
Evoluo da
temperatura
sem colapso
300
200
A = 42 m2
A = 56 m2
A = 90 m2
A = 132 m2
100
0
0
20
40
60
80
100
120
Tempo (min.)
Pgina | 94
compartimento:
A Figura 6.8 mostra a variao da temperatura global do compartimento para
diferentes cargas de incndio e anlise de vrias percentagens de aberturas provenientes da
fissurao inicial do vidro, para uma rea de incndio de 56m2. A fase inicial e a fase de
propagao dependem fundamentalmente da carga de incndio, uma vez que o oxignio
existe em abundncia. Ao variar a percentagem de aberturas, aumenta no s a temperatura
inicial, como tambm a temperatura global mxima do compartimento. No entanto, como
mostra a Tabela 6.4, a partir dos 12% de aberturas, a ventilao deixa de sustentar o
incndio passando a ter o papel inverso. De acordo com Cadorin [31], em caso de
incndios controlados pela carga de incndio, devido grande percentagem de aberturas,
nem todo o ar que entra atravs das aberturas usado na combusto. As perdas por
conveco, que diminuem as temperaturas, encontram-se ligadas troca da massa total dos
gases. Esta alterao diminui o nvel de incndio e reduz a temperatura. Segundo ainda o
mesmo autor, quando a quantidade de gases que passa atravs das aberturas maior que a
ventilao que entra, isto , a parte mais importante de energia produzida pelo incndio
extrada do compartimento por transferncia de massas, isso tambm tende a limitar o
aumento da temperatura global do compartimento. Para efeitos de dimensionamento dos
elementos estruturais (por exemplo, subestrutura, conexes do vidro, etc.), deve ser
considerado a curva de incndio correspondente aos 12% de aberturas, uma vez que,
traduz-se numa curva de incndio mais gravosa. A partir deste patamar a temperatura,
como j referido, tende a diminuir.
Pgina | 95
10% aberturas
12% aberturas
15% aberturas
20% aberturas
600
Temperatura (C)
500
400
10% aberturas
300
12% aberturas
200
15% aberturas
20% aberturas
100
0
0
20
40
60
80
100
120
Tempo (min.)
Figura 6.8 Variao da temperatura do compartimento para diferentes densidades de carga de incndio
e percentagem de aberturas.
Pgina | 96
580
560
Temperatura (C)
540
520
10 % aberturas
500
Habitao
12 % aberturas
480
15 % aberturas
460
20 % aberturas
Escritrio
440
420
Hotel (quarto)
15
20
25
30
35
40
45
Tempo (min.)
(iii)
Pgina | 97
700
A = 25 m2
Temperatura (C)
600
500
400
10% aberturas
A = 56 m2
300
A = 132
12% aberturas
m2
15% aberturas
200
20% aberturas
100
0
0
20
40
60
80
100
120
Tempo (min.)
700
A = 25 m2
Temperatura (C)
600
A = 56 m2
10 % aberturas
500
12 % aberturas
15 % aberturas
A = 132 m2
400
20 % aberturas
300
0
10
20
30
40
50
Tempo (min.)
Pgina | 98
600
TA1
Vidro
temperado
Temperatura (C)
500
400
TA2
300
TF1
Escritrio
Hotel (quarto)
Habitao
200
Vidro
comum
TF2
100
0
0
20
40
60
80
100
120
Tempo (min.)
Figura 6.12 Variao da densidade de carga de incndio para o vidro temperado e o vidro comum.
Pgina | 99
Pgina | 100
Captulo 7
Consideraes finais e desenvolvimentos
futuros
103
104
106
Pgina | 102
Foi efectuada uma introduo ao material em si, onde foram enumeradas as suas
vrias propriedades, importantes no clculo estrutural do vidro. Dentro do fabrico e dos
principais tipos de vidro existentes, fez-se referncia aos que apresentam melhores
caractersticas mecnicas, tendo em vista a sua aplicabilidade estrutural.
Objectivo 2: Reviso bibliogrfica apresentando o estado do conhecimento referente ao
dimensionamento e conexes do vidro estrutural.
Realizou-se uma anlise abrangente s orientaes gerais e regras de confiana, de
forma a executar verificaes rpidas de dimensionamento do vidro e estudo dos vrios
tipos de conexes tradicionais usados em elementos de vidro. Foram enumerados alguns
mtodos de concepo/projecto Europeus e Norte-Americanos, efectuando uma anlise
detalhada, apontando comparaes e limites dos modelos.
Objectivo 3: Avaliao do panorama geral da regulamentao na rea da resistncia ao
fogo e desempenho do vidro em situao de incndio.
Apresentou-se o panorama geral da regulamentao na rea da resistncia ao fogo,
bem como os cenrios de incndio e critrios de desempenho usados em ensaios de
resistncia ao fogo. Foi analisado o desempenho do vidro em situao de incndio.
Objectivo 4: Estudo da influncia da quebra do vidro na temperatura de um
compartimento de incndio.
Foi realizado um estudo sobre a influncia da quebra do vidro, da densidade de carga
de incndio e da rea de compartimento na temperatura global dos gases de um
compartimento de incndio. Comparou-se resultados entre o vidro comum e o vidro
temperado.
Pgina | 103
Pgina | 104
para uma avaliao do desempenho dos elementos estruturais enquanto sujeitos a cenrios
de incndio real. Isto , estipula-se que os elementos estruturais dos edifcios devem
possuir uma resistncia ao fogo que garanta as suas funes de suporte de cargas durante
todas as fases de combate ao incndio, incluindo o rescaldo (abordagem baseada no
desempenho), ou em alternativa devem possuir resistncia mnima ao fogo padro
(abordagem prescritiva). Em relao aos dois tipos de vidro mencionados acima (vidro
temperado e vidro laminado intercalado com PVB), uma vez que no so considerados
habitualmente elementos de proteco contra o fogo e pela quase inexistncia de ensaios
de resistncia ao fogo de elementos estruturais em vidro, importante referir a escassez de
bibliografia cientfica disponvel, tornando de certo modo invivel um estudo mais
exaustivo nessa temtica. No entanto, foi possvel concluir que o vidro temperado
apresenta bom desempenho ao fogo, quando aplicado em elementos sujeitos a esforos
reduzidos (por exemplo, fachadas, divisrias, etc.). Por sua vez, o vidro laminado poder
ser a melhor opo para aplicao em elementos estruturais, sujeitos a carregamentos
considerveis. O desempenho depende de muitos detalhes tcnicos, envolvendo a
instalao e o tipo de vidro utilizado. Se o vidro tiver que resistir a sessenta minutos, o
caixilho, conexo estrutura e/ou materiais usados na montagem do vidro devero seguir a
mesma regra de resistncia.
A anlise efectuada no captulo 6 pretendeu mostrar o interesse significativo do
estudo paramtrico no clculo estrutural em situao de incndio. importante analisar as
diferentes situaes possveis, de forma a efectuar o dimensionamento da estrutura para o
caso mais gravoso. No caso geral, de um compartimento de incndio com uma fachada de
vidro temperado, a variao da percentagem de aberturas, proveniente das aberturas
existentes (portas e janelas abertas, evases do edifcio, etc.) ou da fissurao no
envidraado provocada pelo incndio, pode conduzir a duas situaes distintas:
Pgina | 105
O vidro temperado, devido ao tratamento trmico que sujeito aquando do seu fabrico,
tem uma temperatura de amolecimento superior em aproximadamente 30% em relao ao
vidro comum. Desta forma, o uso do vidro temperado para efeitos de dimensionamento
estrutural, traduz-se num incndio mais gravoso, uma vez que, para que atinja o colapso
necessrio uma temperatura global dos gases muito superior.
Pgina | 106
Referncias Bibliogrficas
Referncias Bibliogrficas
REFERNCIAS BIBLIOGRFICAS
[1] Porter, M. (2001). Aspects of structural design with glass. University of Oxford: A
thesis submitted by Mark Porter for the degree of doctor of philosophy.
[2] Revista SIM. Revista SIM. [Online] 2006. [Citao: 17 de Dezembro de 2009]
http://www.revistasim.com.br/asp/materia.asp?idtexto=4943.
[3] A Vidraaria. A vidraaria - Solues em vidro temperado. [Online] 2009. [Citao:
11 de Fevereiro de 2010] http://www.avidracaria.com.br/index.php/pasta/83/.
[4] Ferreira L.; Costa A.; Almeida, N.; Almeida, J.; Costa, A.; Varum, H.; Morais, M.;
Lopes, N.; Cachim, P.; Vila Real, P. (2006). AveiroDomus - Associao para o
desenvolvimento da Casa do Futuro. Sub Projecto de Engenharia Civil - 1 Relatrio
de progresso, pp. 19-20.
[5] Costa, S.; Miranda, M.; Varum, H.; Teixeira Dias, F. (2006). On the evaluation of the
mechanical behaviour of structural glass elements. Switzerland : Trans Tech
Publications, Materials Science Forum, Vols. 514-516, pp. 799-803.
[6] Universit de Lige, Dpartement M&S. OZone v2.2: The design fire tool OZone
v2.2 - Theoretical description and validation on experimental fire tests. Lige, 2002.
[7] Haldimann, M. (2006). Fracture strength of structural glass elements analytical
and numerical modelling,testing and design. Lausanne, Switzerland : cole
Polytechnique Fdrale de Lausanne. "Pour l'obtention du grade de docteur s
sciences" .
[8] Wikipdia, a enciclopdia livre. Vidro borossilicato. [Online] 14 de Maro de 2010.
http://pt.wikipedia.org/wiki/Vidro_borossilicato.
[9] Chaunac, M.; Serruys, F. (1997). Glass as a structural element. Glass Processing
Days. pp. 197-202.
Pgina | 109
[10] Guerra Martins, J.; Lopes Pinto, E. (2004). Materiais de Construo I - O Vidro. 1
Edio.
[11] Costa, S.; Miranda, M.; Varum, H.; Teixeira Dias, F. (2005). As potencialidades do
vidro como material estrutural. Lisboa : Loja da Imagem, 18 de Novembro,
Engenharia e Vida, Vol. 18.
[12] Pilkington. Glass for Fire - Resistance. [Online] [Citao: 10 de Fevereiro de 2010]
http://www.mace.manchester.ac.uk/project/research/structures/strucfire/DataBase/Ref
erences/Pilkington_Glass%20for%20fire%20resistance.pps.
[13] Haldimann, M.; Luible, A.; Overend, M. (2008). Structural Use of Glass.
Switzerland: International Association for Bridge and Structural Engineering.
[14] Cruz, P.; Carvalho, P.; Paul Lebet, J. (2009). Explorar os limites da conjugao do
vidro e de elementos metlicos em edifcios. Coimbra: Associao Portuguesa de
Construo Metlica e Mista. VII Congresso de Construo Metlica e Mista. pp. I31 a I-45.
[15] Pinto, A. Componentes de edifcios - Aspectos de segurana e resistncia mecnica
do vidro. Laboratrio Nacional de Engenahria Civil (LNEC).
[16] DuPont.
DuPont
SentryGlas
interlayer.
[Online]
2008.
http://www2.dupont.com/SafetyGlass/en_US/assets/pdfs/sentryglas_strength.pdf.
[17] TRLV 2006. Technische Regeln fr die Verwendung von absturzsichernden
Verglsungen (TRAV). Berlin: 2006. Technical Report, Mitteilungen des Deutschen
Instituts fr Bautechnic (DIBt).
[18] TRLV 2003. Technische Regeln fr die Verwendung von absturzsichernden
Verglsungen (TRAV). Berlin: 2003. Technical Report, Mitteilungen des Deutschen
Instituts fr Bautechnic (DIBt).
Pgina | 110
Referncias Bibliogrficas
[19] Colvin, J. (2003). Look - No Frames!. Proceedings of Glass Processing Days 2003,
pp. 208-210.
[20] Cobb, F. (2009). Structural Engineer's Pocket Book - Second edition. Oxford, UK :
Elsevier Science & Technology, pp. 294-304.
[21] Beason, W.L. (1980). A failure prediction model for window glass. NTIS Accession
no. PB81-148421. Texas Tech University : Institute for Disaster Research, USA.
[22] Beason, W.L., Morgan, J.R (1984). Glass Failure Prediction Model. Journal of
Structural Engineering, 110(2): 197-212.
[23] Porter, M.I.; Houslby, G.T. (2001). Development of crack size and limit state design
methods for edge-abraded glass members. The Structural Enginneer. Vols. 79,
No.8.17.
[24] CEN, European Committee for Standardisation (1999). prEN 13474-1:1999. Glass in
building - Design of glass panes - Part 1: General basis of design. Brussels, Belgium.
[25] CEN, European Committee for Standardisation (2000). prEN 13474-2:2000. Glass in
building - Design of glass panes - Part 2: Design for uniformly distributed load.
Brussels, Belgium.
[26] Nederlands Normalisatie Instituut (2007). NEN 2608-2. Vlakglas voor gebouwen Deel 2: Niet-verticaal geplaatst glas - Weerstand tegen eigen gewicht, wind- en
sneeuwbelasting en isochore druk - Eisen en bepalingsmethode. Delft, the
Netherlands.
[27] Deutsches Institut fr Normung (2006). DIN 18008-1 Entwurf. Glas im Bauwesen
Bemessungs- und Konstruktionsregeln Teil 1: Begriffe und allgemeine Grundlagen.
Berlin, Germany.
Pgina | 111
[28] Vitro Chaves. [Online] Vitro, S.A, 2004. [Citao: 3 de Novembro de 2009]
http://www.vitro.com/vitro_chaves/pyroglass1.htm.
[29] Vidraria Sr das Vitrias. Vidraria Sr das Vitrias. [Online] [Citao: 5 de Fevereiro
de 2010.] http://www.vsv.com.pt/catalogopyroglass.htm.
[30] Vila Real, P. (2003). Incndio em estruturas metlicas: clculo estrutural. 1 Edio.
Amadora : Edies Orion.
[31] Cadorin, J. F. (2003). Compartment Fire Models for Structural Engineering. Lige,
Belgique: Faculte des Siences Appliquees, Universit de Lige. Thse de doctorat.
[32] Saint - Gobain Glass. [Online] [Citao: 3 de Novembro de 2009.] http://pt.saintgobain-glass.com/upload/files/3.1.8_o_vidro_e_a_protec__o_contra_o_inc_ndio.pdf.
[33] CEN, European Committee for Standardisation (2002). prEN 13501-2:2002. Fire
classification of construction products and building elements - Part 2: Classification
using data from fire resistance tests, excluding ventilation services. Brussels,
Belgium.
[34] Dirio da Repblica Portuguesa. Decreto-Lei n 220/2008. D.R n 220, 1. srie de 12
de Novembro de 2008. "Estabelece o regime jurdico da segurana contra incncios
em edifcios".
[35] Jesus,
(2008).
Ensaios
de
Resistncia
ao
Fogo
de
Elementos
de
Pgina | 112
Referncias Bibliogrficas
[37] CEN, European Committee for Standardisation. NP EN 1991-1-2. Eurocdigo 1 Aces em estruturas - Parte 1-2: Aces gerais - Aces em estruturas expostas ao
fogo. Caparica, Portugal: Instituto Portugus da Qualidade, 2010.
[38] Nolte, H. H. (1997). Glasses for fire resistant glazed assemblies. Glass Processing
Days, pp. 288-294.
[39] Mejicovsky, T. (2007). Use of laminated glass in structural glass. Glass Performance
Days. Building Projects - Case Studies, pp. 174-178.
[40] Abravidro. Vidros contra as chamas - Resistentes ao fogo, eles evitam sua
propagao em caso de incndio. So Paulo, Brazil : Novembro de 2009, O
Vidroplano, Edio 443, pp. 33-37.
[41] Babrauskas, V. Glass breakage in fires. Fire Science and Technology Inc. [Online]
http://www.doctorfire.com/glass.html.
[42] Morente, F.; Quintana, J. Parte 4: DIFISEK - Software para o dimensionamento em
situao de incndio. Bilbao, Espaa: LABEIN TECNALIA Centro tecnolgico.
[43] Rosmaninho, N.; Lopes, A.; Vaz, G.; Santiago, A.; Silva, L. (2007). Simulao
numrica de um fogo num compartimento: anlise da quebra de uma janela de vidro.
Porto: Associao Portuguesa de Construo Metlica e Mista. VI Congresso de
Construo Metlica e Mista.
Pgina | 113
Anexos
Anexo
Tabela A1.1 Resumo das normas Europeias para produtos bsicos de vidro [7].
Basic soda lime silicate glass products Part 1: Definitions and general
EN 572-1:2004
physical and mechanical properties
EN 572-2:2004
EN 572-3:2004
Basic soda lime silicate glass products Part 3: Polished wire glass
EN 572-4:2004
Basic soda lime silicate glass products Part 4: Drawn sheet glass
EN 572-5:2004
EN 572-6:2004
Basic soda lime silicate glass products Part 6: Wired patterned glass
EN 572-7:2004
EN 572-8:2004
EN 1051-1:2003
EN 1051-2:2003
EN 14178-1:2004
EN 14178-2:2004
EN 572-9:2004
EN 1748-1-1:2004
EN 1748-1-2:2004
EN 1748-2-1:2004
EN 1748-2-2:2004
Pgina | A.1
Tabela A1.2 Resumo das normas Europeias para produtos processados de vidro [7].
Heat strengthened soda lime silicate glass Part 1: Definition and
EN 1863-1:2000
description
Heat strengthened soda lime silicate glass Part 2: Evaluation of
EN 1863-2:2004
conformity / Product standard
Thermally toughened soda lime silicate safety glass Part 1: Definition
EN 12150-1:2000
and description
Thermally toughened soda lime silicate safety glass Part 2: Evaluation
EN 12150-2:2004
of conformity / Product standard
Heat soaked thermally toughened soda lime silicate safety glass Part
EN 14179-1:2005
1: Definition and description
Heat soaked thermally toughened soda lime silicate safety glass Part
EN 14179-2:2005
2: Evaluation of conformity / Product standard
Thermally toughened borosilicate safety glass Part 1: Definition and
EN 13024-1:2002
description
Thermally toughened borosilicate safety glass Part 2: Evaluation of
EN 13024-2:2004
conformity / Product standard
Thermally toughened alkaline earth silicate safety glass Part 1:
EN 14321-1:2005
Definition and description
Thermally toughened alkaline earth silicate safety glass Part 2:
EN 14321-2:2005
Evaluation of conformity / Product standard
Chemically strengthened soda lime silicate glass Part 1: Definition and
EN 12337-1:2000
description
Chemically strengthened soda lime silicate glass Part 2: Evaluation of
EN 12337-2:2004
conformity / Product standard
EN 1096-1:1998
EN 1096-2:2001
EN 1096-3:2001
EN 1096-4:2004
ISO 12543-1:1998
ISO 12543-2:2004
ISO 12543-3:1998
ISO 12543-4:1998
ISO 12543-5:1998
ISO 12543-6:1998
Pgina | A.2
EN 14449:2005
EN 1279-1:2004
EN 1279-2:2002
EN 1279-3:2002
EN 1279-4:2002
EN 1279-5:2005
EN 1279-6:2002
Pgina | A.3
Anexo
MTODO DE DIMENSIONAMENTO
DELR
(Damage Equivalent Load and Resistance)
(q,v)
,,
,
+
q, . A . t. S . , ,
(Ared)
(t)
(Sv)
max,d
bB,Atest,k
Pgina | B.1
V,k
2 0.4 MPa/s);
M,E
M,V
Coeficientes
Um conjunto de coeficientes usado para compensar as diferenas entre as condies de
teste de laboratrio (usado para determinar a resistncia) e as condies reais em servio.
A distribuio de tenses no homognea na superfcie do vidro contabilizado como se
segue:
/
x, y
q, =
dxdy
A ,
1
Blank (1993) com base em experincias em amostras de vidro float com danos artificiais
induzidos homogeneamente pela superfcie (jateamento). Para os casos normais, os valores
de V encontram-se tabelados (a partir de clculos de elementos finitos), mas conservador
assumir V = 1,0.
O tamanho do efeito contabilizado da seguinte forma:
A /
A =
A
O coeficiente (t) representa a durao da carga. Isso depende do crescimento da fenda
crtica, a durao de todas as cargas numa combinao de carregamento, a probabilidade
de sobreposio da carga do vento e neve, a resistncia flexo determinada nos testes, a
taxa de tenso usada nestes testes, a rea de superfcie e o tempo de vida requerido. Para
Pgina | B.2
condies normais usado um perodo de vida til de 50 anos, Sedlacek et al. (1999)
prope a utilizao de (t) = 3,9.
O coeficiente S leva a magnitude relativa das diferentes cargas dentro de uma
Factores parciais
Em Sedlacek et al. (1999), um factor parcial de resistncia de 1.80 proposto para
as estruturas de mdia importncia. Este factor escolhido atravs de uma abordagem
bastante particular envolvendo duas distribuies de Weibull:
Frctil 5% da distribuio
,, = 45 MPa
Weibull
= 74
= 6
, ,
.
, ,
Pgina | B.3
,,
,
+
q, . L . t. S . , ,
Coeficientes
q,
l
=
dl
L ,
1
L /
L =
L
t 3.7
al. (1999) recomenda o uso de = 5 para bordos polidos e = 12.5 para bordos sem
distribuio de tenses uniforme, 0.94 para uma parablica e 0.86 para triangular. S
igual a (Sv).
Pgina | B.4
Anexo
desfavorvel:
= x, y dx dy
A
f,
f, f,
+
.
. k
f,
valor caracterstico da tenso inerente ao vidro (f, = 45 MPa, para vidro sodo-
f,
Pgina | C.1
= ,
condies ambientais [0.72 para durao curta (vento), 0.36 para durao mdia
(neve, aces climticas) e 0.27 para durao permanente (peso-prprio, altitude)];
Vidro
Termo-endurecido
Quimicamente
endurecido
Temperado
Estado
limite
ltimo
Estado
limite de
servio
Estado
limite
ltimo
Estado
limite de
servio
Estado
limite
ltimo
Estado
limite de
servio
Vidro
comum
(float glass)
1.8
1.0
2.3
1.5
2.3
1.5
vidro
borossilicato
1.8
1.0
2.3
1.5
Nota: os factores parciais para outro tipo de produtos de vidro pode ser consultado na
prEN 13474-1:1999.
Tabela C1.2 Factor de tamanho KA [24]
Pgina | C.2
KA
0.2
0.93
0.5
0.97
1.0
1.00
2.0
1.03
5.0
1.07
10.0
1.10
20.0
1.13
Anexo
MTODO DE DIMENSIONAMENTO
SHEN
Nota: A verificao deve ser feita separadamente para cada durao de carga diferente.
A = 4.0 10 m2
Vidro recozido
1.0
0.9
Vidro temperado
1.0
1.0
Pgina | D.1
Vento
(50 anos)
(30 dias)
(10 min.)
Vidro recozido
0.27
0.45
0.69
Vidro temperado
0.74
0.83
1.00
Pgina | D.2
Anexo
MTODO DE DIMENSIONAMENTO
SIEBERT
d,max tenso principal mxima devido s aces (determinada da mesma forma que no
mtodo DELR);
E
sinal negativo);
fA
ftS
fp
. , x, y
=
dA
,,
, x, y
,,
Pgina | E.1
A,
=
A,
, a rea efectiva da amostra. Para simplificar as tabelas de dimensionamento, propese dividir em dois factores como se segue.
f =
f =
, /
,,
,,
Siebert usa uma probabilidade de falha alvo proposta por Blank (1993) e Gsgen (1998).
De acordo com eles, essa probabilidade vale 1,5 10 para estruturas de mdia
importncia. Correspondendo a valores de f = 1.30, usando um valor de = 25.
De acordo com Haldimann [7] ,o factor parcial de Siebert para a tenso residual
Pgina | E.2
, ,
25MPa.
Anexo
B = k cx, y, q, x, y dA
em que cx, y representa o factor de correco da tenso biaxial (em funo da menor para
superfcie. Com base nisto, introduzido para placas de vidro rectangular expostas a
cargas laterais uniformes de durao constante, a seguinte expresso:
Eh
B = kab
/
t
a
m
R
, q,
60
b
cx, y
q, x, y
dA
ab
Pgina | F.1
um tenso adimensional.
Pgina | F.2
Anexo
De acordo com Haldimann [7], a norma Americana ASTM E 1300 uma norma
prtica para determinar a carga resistente do vidro em edifcios, fornecendo grficos
abrangentes de determinao de espessuras necessrias para placas de vidro. baseado no
GFPM onde a resistncia definida usando uma probabilidade de falha alvo de 0,008.
aplicvel a elementos rectangulares verticais ou inclinados de vidro monoltico, laminado
ou isolante de edifcios expostos a uma carga lateral uniforme e com apoio lateral contnuo
de um, dois, trs ou quatro bordos. As cargas especficas de projecto tais como, vento, neve
e peso prprio com magnitude confinada total inferior ou igual a 10kPa. A norma no pode
ser dirigida a aplicaes como balaustradas, painis de vidro em pisos e a membros de
vidro estrutural. O formato de verificao dado por:
q LR = NFL. GTF
sendo q a carga lateral uniforme, LR a carga resistente, NFL a carga sem factorizao
(com base num tempo de carga de 3s) e GTF o denominado factor do tipo de vidro
(depende da durao de carga).
A principal diferena deste mtodo em relao aos mtodos de dimensionamento
europeus, o facto de este formato de verificao ser baseado nas cargas e no em tenses.
Alm disso, no usado qualquer factor parcial.O parmetro NFL determiando a partir
de grficos indicados para diversas geometrias, as condies de apoio, e espessuras de
vidro monoltico, assim como de vidro laminado. GTF combina o tipo de vidro e efeitos da
durao de carga (Tabela G1.1) e dado para painis individuais, bem como para unidades
de vidro isolante.
Tabela G1.1 Factor do tipo de vidro (GTF) para um nico painel de vidro monoltico ou laminado
Tipo de vidro
Carga de curta durao
Carga de longa durao
Vidro recozido
1.0
0.5
Vidro termo-endurecido
2.0
1.3
Vidro temperado
4.0
3.0
Pgina | G.1
= 7, k =
Todos o grficos e valores so calculados usando o GFPM com m
grficos de carga sem factorizao, pretende descrever com preciso a evoluo do mdulo
de rigidez do polmero a 50C. A essa temperatura, com uma durao de carga de 3
segundos (referncia da norma), o PVB caracterizado com um mdulo de Young efectivo
de 1.5MPa. Este valor destinado a ser um limite inferior a intercalares de PVB
comercialmente disponveis.
Para anlises de tenses independentes exigidas, no caso de formas especiais ou
cargas no previstas na norma, as tenses superficiais admissveis para uma carga de
durao de 3 segundos so dadas pela Tabela G1.2. Os valores para os bordos so
definidos a partir de Walker e Muir (1984). Alega-se para a tenso admissvel de 3
segundos e Pf < 0.05 em vidro recozido longe dos bordos, que a seguinte equao deve dar
valores conservadores:
P
=
kd/3/ A
Vidro temperado
23.3
46.6
93.1
16.6
Bordos costurados
18.3
36.5
73.0
Bordos polidos
20.0
36.5
73.0
Pgina | G.2
Para poder comparar os valores das tenses admissveis da Tabela G1.2 para as da
Tabela 3.1, eles devem ser convertidos ao mesmo perodo de tempo de referncia ( =
( = 50MPa).
diferentes duraes (tudo normal para a superfcie de vidro) determinada pela seguinte
expresso3,:
d /
q = q
3
1
q = q . d
3s
Pgina | G.3
Anexo
E R
= + . . + +
factor de importncia: = 1.0 (em geral), 0.8 (edifcios agrcolas com baixa
ocupao humana ou edifcios ao qual o colapso no susceptvel de provocar
consequncias graves);
Pgina | H.1
R = c . c. c . c . R
factor do tipo de vidro: 1.0 (vidro comum, vidro laminado), 0.5 (jateado, gravado
ou vidro aramado);
c2
c3
Vento e sismo
Neve
Peso prprio e presso hidroesttica
c4
Vidro
Vidro
termotemperado
endurecido
Durao aprox.
equivalente
Vidro
recozido
1 min
1.0
1.0
1.0
1 semana a 1 ms
0.5
0.7
0.9
1 ano a 10 anos
0.4
0.6
0.8
Rref
O vidro laminado pode ser considerado como vidro monoltico se a durao da carga for
menor que um minuto e a temperatura inferior a 70C ou se a durao da carga for menor
que uma semana e a temperatura inferior a 20C. Para qualquer outro condio, o vidro
laminado tem de ser considerado como vidro em camadas.
Pgina | H.2