Description AC Induction Machine Type AMI 400L2W BSFS Machine Category Process Performance Quantity of identical units 3
Standards NEMA MG 1 Potentially Hazardous Atmosphere No Max. Ambient Temperature 40 degC Max. Altitude 3,280.84 ft. a.s.l.
Supply Type VSD Load T L /T n @ n/n n ; J (WR 2 ) T L =0 %, 0 %, 0 % @ n =0%, 50%, 100%; J =0 lb.-ft.2 Output 1,249.53392 HP Speed 3,600 rpm Supply 4,160 V / 3 ph / 60.4 Hz Temperature Rise Class B-class Duty Type S1
Mounting / Protection / Cooling F-1 / WP-II / WP-II Insulation Class F, vacuum pressure impregnated Direction of Rotation Counter-clockwise Bearings Standard sleeve bearings, self lubricated Bearing Insulation Insulated NDE only Terminal Box Standard air insulated NEMA main terminal box Quality Assurance ISO 9001 and ISO 14001 Color Standard blue Munsell 8B 4.5/3,25
Documentation - Connection diagram (main and auxiliary) - Dimension drawing of machine - Manual for Induction Motors and Generators (delivered with motor) - Performance data & Current and torque in function of speed - Test report
Tests and Certificates - Routine test according to ABB standard procedure
Painting and corrosion protection - Surface treatment C3 - Standard industrial environment
Accessories - Design for ACS1000 converter drive - Standard vibration acc. to NEMA MG-1 - Self lubricated sleeve bearings, axial float +/- 8mm - NEMA Type II main terminal box - RTD's (Pt-100) in stator windings, 6 pcs, 3-wire, unshielded, safe and hazardous areas - RTD's (Pt-100) in sleeve bearing shell, 1 pc / bearing, 3-wire, shielded, safe areas - Space heater for stator winding, 1 ph - Separate auxiliary terminal box for space heater - Location of ATB for instrumentation: Acc. To MDD - SPM-transducers for continuous vibration monitoring, measuring direction horizontal (H) - Mounting base for vibration monitoring with thread M8x1.25 - Location of space heater's aux. Terminal box: Left - Fabricated aluminium rotor - Seaworthy packing for horizontal machine - Transport lock for sleeve bearings - Documentation in English language - Only final version of documents in defined language - Safety instructions and warning labels in English - Rating and Lubrication plates in English - Warranty 12 months from start-up or 18 months from readiness of delivery, whichever occurs first
Notes, comments and deviations: Driven equipment: 010 Pump Motor type code AMI 400L2W BSFS Motor type Squirrel cage motor Mounting designation F-1 Protected by enclosure WP-II Method of cooling WP-II Insulation Class F Service factor SF1.0 TEMP RISE CLASS B Standards NEMA MG 1 Ambient temperature, max. 40 C Altitude, max. 3300 ft.a.s.l. Converter supply ACS 1000 Duty type Continuous Temp. rise Class B (RES) Connection of stator winding Star Rated output 0 - 1250 HP Voltage 0 - 4160 V Frequency 0 - 60.4 Hz Speed 500.0 - 3600.1 rpm Current 0 - 155 A Power Factor 0 - 0.88 Efficiency 0 - 95.5 % Relat. maximum torque 0 - 2.2 Rated torque 0 - 2473 Nm Direction of rotation Counter-clockwise Weight of rotor 1190 lb Total weight of motor 6548 lb Inertia rotor Approx. 154 lb-ft Bearings Standard sleeve bearings, self lubricated Typical calculated values to NEMA. nomload max load nommotor max motor 3,600 3,400 3,200 3,000 2,800 2,600 2,400 2,200 2,000 1,800 1,600 1,400 1,200 1,000 800 600 400 200 0 T / T b a s e 1.5 1.0 0.5 0.0 max moto nommotor max load nomload
Motor type code: AMI 400L2W BSFS Rated output 1249 HP Power Factor 0.88 Voltage 4160 V 5 % Rated torque 1836 lb-ft Frequency 60 Hz Locked rotor Amps 500 % Speed 3575 rpm Locked rotor torque 40 % Current 155 Amps Breakdown torque 220 %
Equivalent circuit corresponding to star-connection
Running Stator resistance R 1 (248 F) 0.15840 Rotor resistance R 2 ' (212 F) 0.11760 Stator reactance X 1 2.1465 Rotor reactance X 2 ' 1.5620 Magnetizing reactance X m 57.02 Iron loss resistance R Fe 2.35 k