Sei sulla pagina 1di 2

Telecommunications,

Process control,
Energy production and
distribution.
Operating modes
Floating mode (single rate for
use with recombination
batteries)
Automatic equalise mode
(option)
Boost mode for initial and deep
charging of vented batteries
(option).
The current delivered by the
charger is limited, preventing
battery overcharge.
Indications and controls
On front panel :
ON/OFF switch,
Charger/battery DC voltmeter,
Charger output ammeter,
Three LEDs indicating :
- Charger fault/low DC voltage,
- High DC voltage,
- Float charge.
Three LEDs for options,
LED test pushbutton.
Flexibility
A wide range of standard options
enables customised systems to be
produced quickly and
economically.
Earth (ground) insulation fault
monitor,
- AC supply monitor relay,
- Blocking diodes for operation of
MiCOM E10 chargers in parallel,
- Anti-condensation heaters,
- AC supply circuit breaker,
- Isolation transformers for 220V
chargers (standard for other
voltages),
- Output distribution circuit
breakers or fuses (5 maximum),
- Non-standard AC supply
voltages (110 to 600V),
Battery protection fuses,
- Ripple filters for recombination
batteries, limiting current ripple
to 0,1C10.,
- Battery cabinets. Up to 3
according to required
autonomy. These matching
cabinets can be mounted side
by side or vertically to suit the
available space.
Automatic Float/Equalise
charge regime,
- Manual Boost charge for vented
batteries,
- Charge voltage temperature
compensation,
- Special voltage and current
settings,
Cabinet protection to IP 31-41,
- Key locked front panel,
- Special paint finishes,
and any one of the following :
- Low discharge voltage battery
cut-off,
- Low DC voltage alarm monitor,
- Voltage dropping diodes FCEM
(5 maximum) shunted by
contactors during battery
discharge (16 & 25A chargers
only).
MiCOM E10
V
Boost
UI in equalise charge
UI in float charge
Boost current limit
Current
limit
I
Vbo
Vch
Vfl
MiCOM E10 chargers, derived from the MiCOM E range are ideal for applications requiring
DC power supplies less than 6 kW.
This standardised and simplified range provides extremely robust systems with a high level of
reliability which are particularly suited to :
Standard ratings
Cabinet 9.5.4
(H=890 mm, L=530 mm, D=370 mm)
* Wall or floor mounted cabinet.
T&D Protection & Contrle - 95, rue de la Banquire - BP 75 - 34975 Lattes Cedex FRANCE
Tl : 33 (0)4 67 20 54 54 - Fax : 33 (0)4 67 20 54 99 - E-mail:protection.controle@tde.alstom.com
L
1

1
6
3
6

-

0
4
/
9
9
Technics characteristics
A
R
C
E
A
U
X

4
9

Im
p
.

-

T

l.

0
4

9
9

2
3

2
5

0
0
Characteristics
Nominal AC supply voltage : 230V single phase
400 V three phase
Supply voltage tolerance : -10% / +15%
Supply frequency : 50/60 Hz
Supply frequency tolerance : 5%
Ambient temperature range : 0 to 40C
Relative humidity : <90%
Output voltage : 24V - 48V - 110V - 120V - 220V
Static DC regulation : 1 %
Input power factor : 0,85 at full load, three phase
Boost mode current limit : 0,1 C10 Lead acid
0,2 C5 Nickel cadmium
Paint finish : blue RAL 5002 textured semi-gloss
Cooling : fan assisted with thermostatic protection
Cubicle protection degree : IP 30.
Standards
UTE CEI
Low voltage assemblies NFC 63-421 439-1
NFC 63-422 439-2
NFC 63-423 439-3
Semi-condutor NFC 53-211 146-1-1
converters NFC 53-213 146-1-3
NFC 53-221 146-2
Degree of protection of enclosures NFC 20-010 529
Power transformers NFC 52-100 76
Power diodes NFC 96-821
Power thyristors NFC 96-822
Safety Pr EN 50 178
Electromagnetic compatibility EN 50 091-2
CE Marking
Components
UTE CEI
Circuit breakers NFC 63-120 947-2
Cables NFC 30-070 332-1
Low voltage switches NFC 63-130 947-3
Low voltage fuses NFC 63-210 269-2
Measuring instruments NFC 42-100 51-1
Battery packs
The type of battery and the number of battery cabinets can be determined
from the battery selection table.
The autonomy is given for constant power
(where the load comprises DC/DC or DC/AC converters)
or constant current discharges.
The charger rating recommended for the type
of battery selected and the required autonomy is also
shown in the battery selection table.
THREE PHASE
DC
current A
Weight Power DC
voltage V
24 V
48 V
110 V
120 V
220 V
40
60
80
100
25
40
60
80
100
16
25
40
16
25
40
16
25
62
77
90
94
70
89
92
95
103
88
93
104
89
95
105
89
100
1,7
2,4
3,2
4
2
3,1
4,5
5,8
7,3
3,2
4,8
7,6
3,5
5,1
8,4
5,4
8,3
*
kVA
SINGLE PHASE
DC
voltage V
DC
current A
Weight
*
Power
24 V
48 V
110 V
120 V
25
40
60
25
40
16
16
56
69
80
64
87
83
84
1,3
1,8
3
2,6
4,3
4
4,4
kVA
T
h
i
s

b
r
o
c
h
u
r
e

s
h
o
u
l
d

o
n
l
y

b
e

r
e
g
a
r
d
e
d

a
s

a

g
u
i
d
e
.

I
t

c
o
n
t
e
n
t
s

d
o

n
o
t

c
o
n
s
t
i
t
u
t
e

a
n

o
f
f
e
r

f
o
r

s
a
l
e
,

n
o
r

a
d
v
i
c
e

o
n

a
n
y

a
p
p
l
i
c
a
t
i
o
n

f
o
r

a
n
y

p
r
o
d
u
c
t

r
e
f
e
r
r
e
d

t
o

i
n

i
t
.




1
9
9
9

A
L
S
T
O
M

T
&
D

P
r
o
t
e
c
t
i
o
n

&

C
o
n
t
r

l
e

S
A

Potrebbero piacerti anche