Sei sulla pagina 1di 10

DATA

Width of corbel (b) = 0 mm


Thickness of corbel (bw) = 0 mm
Depth of corbel = 0 mm
Depth of beam supported on corbel = 0 m
Lift height reqd for machines = 0 m
Axial Load acting on the column (Pu) = 15 kN
Application of axial load from column centroid = 0 mm
Factored Moment (Mu) = 0.0 kN-m
Characteristic strength of concrete (Fck) = 25 N/mm2
Characteristic strength of Steel (Fy) = 500 N/mm2
Major axis = X-X
Minor axis = Y-Y
Column Geometry
Assume width of column (B) = 250 mm (>= corbel thickness)
Assume depth of column (D) = 250 mm
column unsupported length (Lx) = 4.2 m should be less than 60 d = 15 m
2.73 m K =
column unsupported length (Ly) = 4.2 m (Lx + corbel depth + beam depth)
2.73 K =
cover to reinforcement = 30 mm
Main Reinforcement dia = 12 mm
Least lateral dimension (d) = 250 mm
Column Classification
Lex/D = 10.92 SHORT COLUMN
(Columns with L/d < 12 : short columns ; otherwise long column)
Ley/B = 10.92
Reinforcement
Minimum Reinforcement = 500 mm2 (0.8% BD, Cl. 26.5.3.1. (a) , IS 456)
A) Reinforcement on two sides
(p) = 0.8 % (picked up from below)
Area of Reinforcement Reqd (As) = 500 mm2 (p B D/100)
Reinforcement to be given = 500 mm2
Bar dia = 10 mm
Assume nos. = 8 (minimum no. 4, Cl.26.5.3.1. (c), IS 456)
Effective Length (Lex) =
Effective Length (Ley) =
= 628.3 mm2 OK
Spacing = 59.33 mm (c/c)
B) Reinforcement on four sides
(p) = 0.8 % (picked up from below)
Area of Reinforcement Reqd (As) = 500 mm2 (p B D/100)
Reinforcement to be given = 500 mm2
Bar dia = 10 mm
Assume nos. = 8 (minimum no. 4, Cl.26.5.3.1. (c), IS 456)
(4,8,12,16)
= 628.3 mm2 OK
LATERAL TIES
Max bar dia = 8 mm Cl. 26.5.3.2, (c), IS 456)
Spacing = 160 mm
Combined Axial loading and Bending
Axial load on column = Pu = 15 kN
Applied eccentricity = Ex = 0 mm
Applied eccentricity = Ey = 0 mm
Col. Width = B = 250 mm
Col. Depth = D = 250 mm
Col. unsportd length = l = 4.2 m
Min ecc in x direction = 20.00 mm
Min ecc in y direction = 20.00 mm
DESIGN MOMENTS
Design Moment Mux = M'ux + M'ax
Design Moment Muy = M'uy + M'ay
Moments due to design loads
M'ux = 0.3 kNm
M'uy = 0.30 kNm
Additional moments
M'ax = 0 kNm short column
M'ay = 0 kNm short column
Design Moments
Mux = 0.3 kNm
Muy = 0.30 kNm
MOMENTS CAPACITY
d' = 36 mm
D = 250 mm
B = 250 mm
d'/D = 0.15
d'/B = 0.15
Pu = 0.010
Fck B D
Assume reinforcement % p = 0.8
fck = 25 N/mm2
fy = 500 N/mm2
p/fck = 0.032
For Mux1 d'/D = 0.15
For Muy1 d'/B = 0.15
Pu/fck BD 0.010
For Reinforcement on two sides
Mux1 = 0.06 Mux1 = 23.44 kNm
fck BD
2
(chart 35-38, SP16)
Muy1 = 0.06 Muy1 = 23.44 kNm
fck B
2
D (chart 35-38, SP16)
As = 628.3 mm2
Ac = 61871.68 mm2
Puz = 931.68 kN
a = 0.016
a to be used = 1
(Mux/Mux1)
a
+ (Muy/Muy1)
a
= 0.026 OK
For Reinforcement on four sides
Mux1 = 0.059 Mux1 = 23.05 kNm
fck BD
2
(chart 47-50, SP16)
Muy1 = 0.059 Muy1 = 23.05 kNm
fck B
2
D (chart 47-50, SP16)
As = 628.3 mm2
Ac = 61871.68 mm2
Puz = 931.68 kN
Pu/Puz = 0.016
a to be used = 1
(Mux/Mux1)
a
+ (Muy/Muy1)
a
= 0.026 OK
X
Y bw Y
B
D b Load from supported beam and live load (axial load)
X
(Grade same as corbel)
(>= corbel thickness)
should be less than 60 d = 15 m (Cl. 25.3, IS 456) Ly
0.65 Table 28, IS 456
(Lx + corbel depth + beam depth)
0.65 Table 28, IS 456
eccentricity (e) = 125 mm
SHORT COLUMN (Cl. 25.1.2, IS 456)
(Columns with L/d < 12 : short columns ; otherwise long column)
(0.8% BD, Cl. 26.5.3.1. (a) , IS 456)
(picked up from below)
(p B D/100)
(minimum no. 4, Cl.26.5.3.1. (c), IS 456)
corbel

column

(picked up from below)
(p B D/100)
(minimum no. 4, Cl.26.5.3.1. (c), IS 456)
Cl. 26.5.3.2, (c), IS 456)
X
Y
B
D
column

X
Load from supported beam and live load (axial load)
Lx
Y

Potrebbero piacerti anche