Thickness of corbel (bw) = 0 mm Depth of corbel = 0 mm Depth of beam supported on corbel = 0 m Lift height reqd for machines = 0 m Axial Load acting on the column (Pu) = 15 kN Application of axial load from column centroid = 0 mm Factored Moment (Mu) = 0.0 kN-m Characteristic strength of concrete (Fck) = 25 N/mm2 Characteristic strength of Steel (Fy) = 500 N/mm2 Major axis = X-X Minor axis = Y-Y Column Geometry Assume width of column (B) = 250 mm (>= corbel thickness) Assume depth of column (D) = 250 mm column unsupported length (Lx) = 4.2 m should be less than 60 d = 15 m 2.73 m K = column unsupported length (Ly) = 4.2 m (Lx + corbel depth + beam depth) 2.73 K = cover to reinforcement = 30 mm Main Reinforcement dia = 12 mm Least lateral dimension (d) = 250 mm Column Classification Lex/D = 10.92 SHORT COLUMN (Columns with L/d < 12 : short columns ; otherwise long column) Ley/B = 10.92 Reinforcement Minimum Reinforcement = 500 mm2 (0.8% BD, Cl. 26.5.3.1. (a) , IS 456) A) Reinforcement on two sides (p) = 0.8 % (picked up from below) Area of Reinforcement Reqd (As) = 500 mm2 (p B D/100) Reinforcement to be given = 500 mm2 Bar dia = 10 mm Assume nos. = 8 (minimum no. 4, Cl.26.5.3.1. (c), IS 456) Effective Length (Lex) = Effective Length (Ley) = = 628.3 mm2 OK Spacing = 59.33 mm (c/c) B) Reinforcement on four sides (p) = 0.8 % (picked up from below) Area of Reinforcement Reqd (As) = 500 mm2 (p B D/100) Reinforcement to be given = 500 mm2 Bar dia = 10 mm Assume nos. = 8 (minimum no. 4, Cl.26.5.3.1. (c), IS 456) (4,8,12,16) = 628.3 mm2 OK LATERAL TIES Max bar dia = 8 mm Cl. 26.5.3.2, (c), IS 456) Spacing = 160 mm Combined Axial loading and Bending Axial load on column = Pu = 15 kN Applied eccentricity = Ex = 0 mm Applied eccentricity = Ey = 0 mm Col. Width = B = 250 mm Col. Depth = D = 250 mm Col. unsportd length = l = 4.2 m Min ecc in x direction = 20.00 mm Min ecc in y direction = 20.00 mm DESIGN MOMENTS Design Moment Mux = M'ux + M'ax Design Moment Muy = M'uy + M'ay Moments due to design loads M'ux = 0.3 kNm M'uy = 0.30 kNm Additional moments M'ax = 0 kNm short column M'ay = 0 kNm short column Design Moments Mux = 0.3 kNm Muy = 0.30 kNm MOMENTS CAPACITY d' = 36 mm D = 250 mm B = 250 mm d'/D = 0.15 d'/B = 0.15 Pu = 0.010 Fck B D Assume reinforcement % p = 0.8 fck = 25 N/mm2 fy = 500 N/mm2 p/fck = 0.032 For Mux1 d'/D = 0.15 For Muy1 d'/B = 0.15 Pu/fck BD 0.010 For Reinforcement on two sides Mux1 = 0.06 Mux1 = 23.44 kNm fck BD 2 (chart 35-38, SP16) Muy1 = 0.06 Muy1 = 23.44 kNm fck B 2 D (chart 35-38, SP16) As = 628.3 mm2 Ac = 61871.68 mm2 Puz = 931.68 kN a = 0.016 a to be used = 1 (Mux/Mux1) a + (Muy/Muy1) a = 0.026 OK For Reinforcement on four sides Mux1 = 0.059 Mux1 = 23.05 kNm fck BD 2 (chart 47-50, SP16) Muy1 = 0.059 Muy1 = 23.05 kNm fck B 2 D (chart 47-50, SP16) As = 628.3 mm2 Ac = 61871.68 mm2 Puz = 931.68 kN Pu/Puz = 0.016 a to be used = 1 (Mux/Mux1) a + (Muy/Muy1) a = 0.026 OK X Y bw Y B D b Load from supported beam and live load (axial load) X (Grade same as corbel) (>= corbel thickness) should be less than 60 d = 15 m (Cl. 25.3, IS 456) Ly 0.65 Table 28, IS 456 (Lx + corbel depth + beam depth) 0.65 Table 28, IS 456 eccentricity (e) = 125 mm SHORT COLUMN (Cl. 25.1.2, IS 456) (Columns with L/d < 12 : short columns ; otherwise long column) (0.8% BD, Cl. 26.5.3.1. (a) , IS 456) (picked up from below) (p B D/100) (minimum no. 4, Cl.26.5.3.1. (c), IS 456) corbel
column
(picked up from below) (p B D/100) (minimum no. 4, Cl.26.5.3.1. (c), IS 456) Cl. 26.5.3.2, (c), IS 456) X Y B D column
X Load from supported beam and live load (axial load) Lx Y