Sei sulla pagina 1di 37

50PV - PRODUCT DATA DIGEST

WATER
COOLED
PACKAGED
UNITS

QUALITY SYSTEM

MALAYSIA
MS ISO 9001
REG. NO: AR 0239

Compact, self-contained unit that offer low installation cost plus dependable
performance.
From Carrier's excellence in engineering comes a new, compact of single package cooling unit - the 50BP080 up to
900. They are available as water cooled package units with a capacity of 23.2kW up to 264.3kW. They are
engineered for commercial or industrial applications. These units are attractively styled to meet your new
construction or renovation needs.

FEATURES:
Compact design - save installation space.
Water cooled package for vertical air discharge. Fan assembly can be easily field or factory positioned for
horizontal air discharge for 50BP260 to 50BP450.
50BP080 and 50BP100 are supplied with - 3 speed direct driven fan motor.
50BP160 to 50BP900 are supplied with taper lock pulleys and wedge belts for better quanlity and easy servicing.
Free blow option with plenum for horizontal air discharge is availabe for 50BP080 and 50BP100.
Compact shell and tube water cooled condenser with enhanced fin tubes for better performance and easy cleaning.
Fully hermetic (50BP080 to 50BP200) and semi hermetic compressor with piston unloader for capacity control
(50BP260 to 50BP450). 50BP160 and 50BP200 are supplied with dual fully hermetic compressors. 50BP680
and 50BP900 are supplied with dual semi hermetic compressor without piston unloader.
Safety features like high & low pressure switches, crankcase heater, lock out relay and solid state anti short
cycle timer are standard supplied with the units.
Condenser water pipe can either be left or right side connections and easily be changed in the field.
Slide-in or slide-out fan deck assembly for easy servicing and maintenance for 50BP080 & 50BP100.
Powder painted cabinet complies with ASTM B117 for 500 hours salt-spray test.
Integral filter frame and cleanable type filters are factory supplied.
Front access control with indicator light for power on and fault status are easily accessible.
50BP680 & 50BP900 have side access control.

PHYSICAL DATA
MODEL NO: 50BP

080

100

160

200

260

340

450

520

680

900

kW

23.2

29.7

45.8

58.8

75.3

96.6

130.1

161.4

199.7

264.3

Btu/h

79 160

101 340

156 270

200 625

256 925

336 420

443 900

550 858

681 000

902 000

kg

240

290

552

634

720

790

950

1500

2050

2550

15.0

17.0

12.0

15.0

17.0

12.0

15.0

17.0

NOMINAL CAPACITY*
OPERATING WEIGHT
REFRIGERANT

R-22

OPERATING CHARGE

Circuit 1
Circuit 2
NOMINAL POWER SUPPLY
COMPRESSOR
Type
No. of compressor
No. of capacity step
% of unloading
CONDENSER
Type
No. of condenser
INDOOR FAN

4.7

5.0

4.7

5.0

kg

4.7

5.0

10.0
-

V-Ph-Hz

400 - 3 - 50
Reciprocating Fully Hermetic

Reciprocating Semi Hermetic

0/100

0/100

0/50/100

0/50/100

0/66/100

0/66/100

0/50/100

0/50/100

0/50/100

0/66/100

Shell & Tube

Type
Drive
Pulley pitch diameter
Air quantity - max**

Centrifugal Forward Curved


Direct Drive

Air quantity - min**


FAN MOTOR
Type
STD fan speed
Fan speed, H
M

L
Max. allowable rpm
Pulley pitch diameter
Motor kW
No. of fan motor
INDOOR COIL
Rows - fins/m
Face area
RETURN AIR FILTER
Type
No.
Size

kg

Belt Drive

mm

125

132

160

200

200

335

300

280

l/s

1280

1675

2750

3600

4150

5000

5750

7500

10000

11000

cfm

2172

3549

5826

7627

8792

10593

12182

15890

21186

23305

l/s

650

940

1600

2200

3000

3500

4500

4500

5000

8000

cfm

1377

1992

3390

4661

6356

7415

9534

9534

10593

16949

rpm

870

1000

860

860

1100

940

870

830

1350

1350

1200

1200

1100

1100

1350

1350

1200

1200

1100

1100

1200

1100

1100

1100

3 Speed Motor

1 Speed Motor

mm

75

95

95

118

160

200

180

160

kW

0.73

1.10

2.2

3.7

3.7

5.5

7.5

11.0

11.0

15.0

2 - 709

2 - 709

2 - 709

3 - 709

3 - 590

3 - 590

3 - 590

3 - 590

3 - 590

4 - 590

0.63

0.63

1.17

1.17

1.40

1.64

1.90

3.09

3.80

4.62

sq. m

Washable

Washable/Throwaway

1
mm x mm

1012 x 616

1266 x 924

1584 x 599

Washable

Washable/Throwaway

16

16

16/4

1782 x 599

500 x 395/

406 x 635

406 x 635/

595 x 395

406 x 508

CONNECTIONS

Condenser - water inlet


Condenser - water outlet
Drain
CONTROL PRESSURE
SETTING
High cut-out
High cut-in
Low cut-out
Low cut-in
*

1 1/4"BSP (MPT)

1 1/2"BSP (MPT) 1 1/2"BSP (MPT) 2 1/2"BSP (MPT)

1 1/2"BSP (MPT)

1 1/4"BSP (MPT)

1 1/2"BSP (MPT) 1 1/2"BSP (MPT) 2 1/2"BSP (MPT)

1 1/2"BSP (MPT)

2 1/2"BSP (MPT)

1"NPT (FPT)

1 1/2"NPT (FPT) 1 1/2"BSP (MPT) 1 1/2"NPT (FPT)

1 1/2"NPT (FPT)

1 1/2"NPT (FPT)

psig

310
210
27
67

Data are rated to JIS at standard condition

** For specific requirement refer to the fan curve performance


*** Single phase fan motor amps.

2 1/2"BSP (MPT)

ELECTRICAL DATA
VOLT RANGE
MODEL

V/Ph/Hz

MIN

MAX

50BP080

400/3/50

342

440

COMP 1/COMP 2
MAXIMUM

LRA 1/

RLA 1/RLA 2

LRA 2

19/-

FAN MOTOR
kW

FLA

80/-

0.73

*5.5

POWER SUPPLY
MIN. CKT

MOCP

AMPS

AMPS

29.3

48.3

50BP100

400/3/50

342

440

22.1/-

143/-

1.35

*8.6

36.2

58.3

50BP160

400/3/50

342

440

19/19

80/80

2.2

4.7

48.3

67.3

50BP200

400/3/50

342

440

22.1/22.1

143/143

3.7

7.7

57.4

79.5

50BP260

400/3/50

360

440

36/-

173/-

3.7

7.7

52.7

88.7

50BP340

400/3/50

360

440

56/-

253/-

5.5

10.9

80.9

136.9

50BP450

400/3/50

360

440

77/-

345/-

7.5

14.4

110.7

187.7

50BP520

400/3/50

360

440

55/55

200/200

11.0

20.7

144.5

199.5

50BP680
50BP900

400/3/50
400/3/50

360
360

440
440

56/56
77/77

253/253
345/345

11.0
15.0

20.7
28.1

146.7
201.4

202.7
278.4

RLA
LRA
FLA
MOCP
*

:
:
:
:
:

Maximum Rated Load Amps (Maximum Continuous Current)


Locked Rotor Amps
Full Load Amps
Max. Over Current Protection Device
Single Phase Motor Amps

DIMENSION
50BP080, 50BP100

* - WATER CONNECTIONS ARE INTERCHANGEABLE EITHER LEFT OR RIGHT. (Standard Factory Supply is on the right)
- CENTER OF GRAVITY
** - FOR NON STANDARD UNIT ONLY

DIMENSION
50BP160, 50BP200

* - WATER CONNECTIONS ARE INTERCHANGEABLE EITHER LEFT OR RIGHT. (Standard Factory Supply is on the right)
- CENTER OF GRAVITY
** - FOR NON STANDARD UNIT ONLY

DIMENSION
50BP260, 50BP340

MODEL
50BP260
50BP340

CONDENSER PIPE SIZE


WATER IN
WATER OUT
*1 1/2 BSP
*1 1/2 BSP
*2 1/2 BSP
*2 1/2 BSP

DIMENSION
DIM A
DIM B
98.0
202.1
150.0
209.3

* - WATER CONNECTIONS ARE INTERCHANGEABLE EITHER LEFT OR RIGHT. (Standard Factory Supply is on the right)
- CENTER OF GRAVITY
** - FOR NON STANDARD UNIT ONLY

DIMENSION
50BP450

MODEL
50BP450

CONDENSER PIPE SIZE


WATER OUT
WATER IN
*2 1/2 BSP
*2 1/2 BSP

* - WATER CONNECTIONS ARE INTERCHANGEABLE EITHER LEFT OR RIGHT. (Standard Factory Supply is on the right)
- CENTER OF GRAVITY
** - FOR NON STANDARD UNIT ONLY

DIMENSION
50BP520

MODEL
50BP520

CONDENSER PIPE SIZE


WATER OUT
WATER IN
*1 1/2 BSP
*1 1/2 BSP

* - WATER CONNECTIONS ARE INTERCHANGEABLE EITHER LEFT OR RIGHT. (Standard Factory Supply is on the right)
- CENTER OF GRAVITY
** - FOR NON STANDARD UNIT ONLY

DIMENSION
50BP680, 50BP900

UNIT 50BP
680
900

A
2600
3100

B
395
645

CONDENSER PIPE SIZE


MODEL
WATER IN
WATER OUT
50BP680/900
2 -1/2BSP
2 -1/2BSP

C
2490
2990

* - WATER CONNECTIONS ARE INTERCHANGEABLE EITHER LEFT OR RIGHT. (Standard Factory Supply is on the right)
- CENTER OF GRAVITY
** - FOR NON STANDARD UNIT ONLY

10

SELECTION PROCEDURE

4. Determine condenser water requirements.

1. Determine design conditions:Given:


Total Cooling Capacity ......................................... 94kW
Sensible Heat Capacity ....................................... 70kW
Evaporator Air Quantity .................................... 4250l/s
External Static Pressure .................................... 200Pa
Mixed Ent Air Conditions
(tedb) ............................................................. 28C DB
(tewb) .............................................................. 9.5 WB
Condenser Entring Water
Temperature .......................................................... 30C
Design Temperature Rise ....................................... 5C

a. Requirement water flow can be determine using the


formula below:
= TC (kW) + Power Input (kW)
Water Temp Rise (C) x 0.07
= 96.0 + 25.8 = 121.8
5 x 0.07
0.35
= 348 l/min
b. Enter condenser pressure drop chart at the determined
water flow 348l/min. Read from the intersection on the
curve to the left scale to obtain the water pressure
drop (2 kPa). A proper water pump can be selected
based on this value.

2. Select based on cooling requirements.


a. Enter 50BP cooling capacity table at given evaporator
air quantity (4250l/s) and condenser leaving temperature
(35C). Determine total cooling capacity (TC) and sensible
heat capacity (SHC) at given entering air wb (19.5C).
A 50BP340 unit has capacity of 96.0 kW (TC) and
69.7kW (SHC) with compressor power input of 25.8 kW.

CAPACITY NOTES
1. Gross capacities do not include deduction for indoor
fan motor heat.

b. Correct SHC value for entering air temperature other


than 27C.
SHC' = SHC = 1.23(1-BF) (tedb-27) (l/s/1000)
= 69.7 + 1.23(1-0.08) (28-27) (4250/1000)
= 74.5kW
Correct SHC = 74.5kW
Thus, 50BP340 unit can fulfill the specified load
requirement.

2. SHC is based on 27C DB temp of air entering indoor unit.


Correction based on the following formula is necessary
if the air temperature is below or above 27C DB.
SHC' = SHC + 1.23(1-BF) x (tedb-27) (l/s/1000)
Where
SHC' : Sensible heat capacity corrected, kW.
SHC : Sensible heat capacity in the table, kW.

3. Determine static pressure.

3. Direct interpolation is permissible. Do not extrapolate.

From 50BP340 Fan Curve:


Locate on the curve where the specified air quantity
(4250 l/s) and external static pressure (200 Pa)
intersect.

4. Nominal capacity is based on max. air quantity, 19.5C


entering wet-bulb and 35C condenser leaving water
temperature.

The intersect point is under 5.5kW line and fan rpm


can be determined as 910 rpm. The standard 5.5kW
motor can satisfy the requirements.

11

FAN MOTORS AND DRIVES (For 50BP160 TO 50BP900)


1.
2.
3.
4.

50BP080 & 50BP100 are furnished with direct drive 3 speed motor.
Standard motors and drives are furnished for all units.
Special motors and drives must be purchased locally.
Determine the special drives with the following equations.

UNIT
50BP

FAN
MOTOR

FAN
RPM

KW
160
200
260
340
450
520
680
900

PITCH DIA (MM)


MOTOR
PULLEY

BELT

FAN
PULLEY

SIZE
(MM)

NO.

CENTER
LINE

FAN
SHAFT

DISTANCE
(MM)

DIA
(MM)

STD
ALT
STD

2.2
3.7
3.7

870
1000

75
95

125
132

825
825

2
2

254+40
248+40
224+40

ALT
STD

5.5
3.7

860

95

160

1562

213+40
585+10

ALT

5.5

565+10

STD
ALT

5.5
7.5

860
-

118
-

200
-

1637
-

2
-

565+10
545+10

STD
ALT
STD

7.5
11.0

1100
940

160
200

200
335

1762
2320

2
2

597+10
737+10

ALT
STD
ALT
STD

11.0
15.0
15.0

870
830

180
160

300
280

2200
2112

2
3

726+14
726+14

ALT

18.5

+0

Equation 1: Pulley Pitch Diameter


PDf

PDm

PDf
PDm
RPSf
RPSm
Lb
Lw
Sb

PDm x RPSm
RPSf
PDf x RPSf
RPSm

Equation 2: V Belt Length


Lb = 2 x Lw + (PDm + PDf) + (PDm - PDf) 2
2
4 x Lw

Equation 3: V Belt Size


Sb = Lb
25.4

12

35.0 - 0.062

+0.018

48.0 +0.002

+0

35.0 - 0.062

Fan pulley pitch diameter (mm)


Motor pulley pitch diameter (mm)
Fan speed
Motor speed
V belt length (mm)
Center line distance (mm)
V belt size

PERFORMANCE DATA
PERFORMANCE DATA
50BP - 080 COOLING CAPACITY
LEAVING
CONDENSER

EVAPORATOR AIR (L/S)/B.F.

WATER

900/0.08

1086/0.22

TEMPERATURE
(C)

22.0
30

35

40

45

TC
SHC
KW

1280/0.25

EVAPORATOR AIR ENTERING WET BULB (C)


19.5

17.0

22.0

19.5

17.0

22.0

19.5

17.0

TC

25.12

13.15

21.45

25.70

23.74

22.12

26.14

24.12

22.64

SHC

12.44

15.33

18.06

13.15

16.55

19.87

13.85

17.69

21.20

KW

5.80

5.61

5.44

5.88

5.69

5.53

5.94

5.74

5.60

TC

24.15

22.27

20.64

24.66

22.79

21.27

25.07

23.15

21.79

SHC

12.04

14.21

17.65

12.78

16.14

19.31

13.44

17.31

20.72

KW

6.21

6.01

5.84

6.29

6.09

5.93

6.35

6.16

6.04

TC

23.15

20.90

19.83

23.64

21.83

20.42

23.97

22.16

20.91

SHC

11.67

14.56

17.24

12.37

15.73

18.87

13.04

16.92

20.20

KW

6.66

6.45

6.26

6.73

6.53

6.36

6.80

6.59

6.44

TC

22.16

20.42

18.98

22.56

20.86

19.53

22.86

21.16

20.04

SHC

11.30

14.43

16.84

12.00

15.36

18.39

12.93

16.47

19.65

KW

7.13

6.92

6.73

7.21

6.70

6.83

7.28

7.06

6.91

TOTAL CAPACITY (KW)


SENSIBLE HEAT CAPACITY (KW)
COMPRESSOR MOTOR POWER INPUT (KW)

PERFORMANCE DATA
50BP - 100 COOLING CAPACITY
LEAVING
CONDENSER

EVAPORATOR AIR (L/S)/B.F.

WATER

1100/0.18

1370/0.22

TEMPERATURE

EVAPORATOR AIR ENTERING WET BULB (C)

(C)
30

35

40

45

TC
SHC
KW

1675/0.25

22.0

19.5

17.0

22.0

19.5

17.0

22.0

19.5

17.0

TC

31.90

29.44

27.15

32.88

30.35

28.17

33.62

31.09

29.02

SHC

15.55

18.85

21.98

16.49

20.43

24.20

17.48

22.12

26.45

KW

8.21

7.90

7.61

8.36

8.05

7.78

8.47

8.17

7.92

TC

30.60

28.21

26.06

31.51

29.09

26.98

32.18

29.72

27.78

SHC

15.02

18=.32

21.45

15.97

19.87

23.60

16.95

21.56

25.81

KW

8.65

8.32

8.02

8.80

8.48

8.19

8.93

8.60

8.34

TC

29.30

26.98

24.90

30.07

27.71

25.78

30.70

28.35

26.55

SHC

14.49

17.76

20.89

15.40

19.31

23.00

16.39

21.00

25.15

KW

9.11

8.75

8.42

9.26

8.90

8.60

9.40

9.04

8.77

TC

27.89

25.64

23.70

28.52

26.34

24.51

29.05

26.83

25.25

SHC

13.93

17.20

20.29

14.81

18.71

22.33

15.76

20.36

24.37

KW

9.56

9.16

8.81

9.69

9.33

9.01

9.82

9.46

9.19

TOTAL CAPACITY (KW)


SENSIBLE HEAT CAPACITY (KW)
COMPRESSOR MOTOR POWER INPUT (KW)

13

PERFORMANCE DATA
50BP - 160 COOLING CAPACITY
LEAVING
CONDENSER

EVAPORATOR AIR (L/S)/B.F.

WATER

1600/0.06

2175/0.09

TEMPERATURE
(C)

22.0
30

35

40

45

TC
SHC
KW

2750/0.12

EVAPORATOR AIR ENTERING WET BULB (C)


19.5

17.0

22.0

19.5

17.0

22.0

19.5

17.0

TC

48.7

44.9

41.6

50.4

46.5

43.4

51.8

47.8

44.8

SHC

24.1

29.7

35.0

25.8

32.4

38.9

27.

35.0

42.0

KW

10.9

10.5

10.2

11.0

10.7

10.4

11.1

10.7

10.5

TC

46.9

43.2

40.0

48.3

45.3

41.7

49.6

45.8

43.1

SHC

23.4

27.6

34.2

25.0

32.1

37.8

26.6

34.3

41.0

KW

11.6

11.3

10.9

11.8

11.4

11.1

11.9

11.5

11.3

TC

44.9

42.5

38.5

46.8

42.8

40.0

47.5

43.9

41.4

SHC

22.6

28.2

33.4

24.2

30.8

37.0

25.8

35.5

40.0

KW

12.5

12.1

11.7

12.6

12.2

11.9

12.7

12.3

12.1

TC

43.0

39.6

36.8

44.2

40.9

38.3

45.3

41.9

39.6

SHC

21.9

28.0

32.7

23.5

30.1

36.0

25.0

32.6

38.9

KW

13.3

13.0

12.6

13.5

12.5

12.4

13.6

13.2

12.9

- TOTAL CAPACITY (KW)


- SENSIBLE HEAT CAPACITY (KW)
- COMPRESSOR MOTOR POWER INPUT (KW)

PERFORMANCE DATA
50BP - 200 COOLING CAPACITY
LEAVING
CONDENSER

EVAPORATOR AIR (L/S)/B.F.

WATER

2200/0.07

2900/0.10

TEMPERATURE

EVAPORATOR AIR ENTERING WET BULB (C)

(C)
30

35

40

45

TC
SHC
KW

3600/0.13

22.0

19.5

17.0

22.0

19.5

17.0

22.0

19.5

17.0

TC

61.9

57.1

52.7

64.4

59.5

55.2

66.6

61.6

57.5

SHC

30.2

36.8

42.6

32.3

40.0

47.4

34.6

43.8

52.4

KW

16.1

15.5

14.9

16.3

15.7

15.1

16.7

16.2

15.7

TC

59.4

54.7

50.6

61.8

57.5

52.9

63.7

58.8

55.0

SHC

29.1

35.5

41.6

31.3

39.3

46.3

33.6

42.7

51.1

KW

16.9

16.3

15.7

17.1

16.5

15.9

17.7

17.0

16.5

TC

56.8

52.3

48.3

58.9

54.3

50.5

60.8

56.1

52.6

SHC

28.1

34.5

40.5

30.2

37.8

45.1

32.5

41.6

49.8

KW

17.8

17.1

16.5

18.0

17.3

16.7

18.8

17.9

17.3

TC

54.4

49.7

46.0

55.9

51.6

48.0

57.5

53.1

50.0

SHC

27.0

33.4

39.4

29.0

36.7

43.6

31.2

40.3

48.3

KW

18.7

17.9

17.3

18.8

18.2

17.5

19.4

18.7

18.2

- TOTAL CAPACITY (KW)


- SENSIBLE HEAT CAPACITY (KW)
- COMPRESSOR MOTOR POWER INPUT (KW)

14

PERFORMANCE DATA
50BP - 260 COOLING CAPACITY
LEAVING
CONDENSER

EVAPORATOR AIR (L/S)/B.F.

WATER

3000/0.06

3575/0.07

TEMPERATURE
(C)

22.0
30

35

40

45

TC
SHC
KW

4150/0.09

EVAPORATOR AIR ENTERING WET BULB (C)


19.5

17.0

22.0

19.5

17.0

22.0

19.5

17.0

TC

82.0

74.2

69.6

84.5

76.7

72.2

86.5

78.7

74.4

SHC

42.0

52.3

59.1

44.8

56.9

64.8

48.5

61.2

70.0

KW

15.6

15.5

15.4

15.7

15.6

15.5

15.7

15.6

15.5

TC

78.6

71.0

66.7

81.0

73.4

69.2

82.8

75.3

71.5

SHC

40.7

51.0

57.8

43.6

55.5

63.2

46.3

59.8

68.1

KW

17.3

17.0

16.8

17.3

17.1

17.0

17.4

17.2

17.1

TC

75.2

67.9

63.8

77.5

70.2

66.3

79.1

72.0

68.6

SHC

39.5

49.6

56.3

42.3

54.1

61.7

44.9

58.4

66.2

KW

18.9

18.5

18.3

19.0

18.7

18.4

19.1

18.7

18.6

TC

71.9

64.9

60.8

73.9

66.9

63.3

75.4

68.6

65.7

SHC

38.1

48.3

54.9

41.0

52.8

60.1

43.6

56.8

63.9

KW

20.5

20.0

19.6

20.6

20.2

19.9

20.7

20.3

20.1

TOTAL CAPACITY (KW)


SENSIBLE HEAT CAPACITY (KW)
COMPRESSOR MOTOR POWER INPUT (KW)

PERFORMANCE DATA
50BP - 340 COOLING CAPACITY
LEAVING
CONDENSER

EVAPORATOR AIR (L/S)/B.F.

WATER

3500/0.06

4250/0.08

TEMPERATURE

EVAPORATOR AIR ENTERING WET BULB (C)

(C)
30

35

40

45

TC
SHC
KW

5000/0.09

22.0

19.5

17.0

22.0

19.5

17.0

22.0

19.5

17.0

TC

105.4

96.2

90.4

109.2

99.6

94.1

112.1

102.5

97.6

SHC

53.1

64.5

73.3

56.8

71.4

81.0

60.3

77.0

87.9

KW

24.0

23.7

23.4

24.0

23.8

23.6

24.1

23.9

23.7

TC

101.5

92.5

86.9

105.4

96.0

90.5

108.3

98.6

93.5

SHC

51.5

63.8

71.9

55.2

69.7

79.3

55.1

75.3

85.9

KW

26.1

25.6

25.2

26.3

25.8

25.5

26.4

26.0

25.7

TC

97.6

88.7

83.3

101.5

92.1

86.8

103.4

94.6

89.8

SHC

50.0

62.2

70.2

53.7

68.1

77.5

57.1

73.6

84.0

KW

28.3

27.6

27.1

28.5

27.9

27.4

28.7

28.1

27.7

TC

93.8

85.0

79.9

96.7

88.1

83.1

99.6

90.5

86.0

SHC

48.3

60.4

68.4

52.0

66.3

75.7

51.6

71.9

82.0

KW

30.4

29.5

28.9

30.7

29.8

29.3

30.9

30.1

29.6

TOTAL CAPACITY (KW)


SENSIBLE HEAT CAPACITY (KW)
COMPRESSOR MOTOR POWER INPUT (KW)

15

PERFORMANCE DATA
50BP - 450 COOLING CAPACITY
LEAVING
CONDENSER

EVAPORATOR AIR (L/S)/B.F.

WATER

4500/0.07

5125/0.08

TEMPERATURE
(C)
30

35

40

45

TC
SHC
KW

5750/0.10

EVAPORATOR AIR ENTERING WET BULB (C)


22.0

19.5

17.0

22.0

19.5

17.0

22.0

19.5

17.0

TC

141.6

129.1

120.8

144.7

132.2

123.9

147.8

134.3

127.0

SHC

71.3

88.3

99.6

74.6

93.6

106.2

77.8

98.8

112.4

KW

33.5

32.7

32.1

33.7

32.9

32.4

33.8

33.1

32.6

TC

136.4

123.9

116.6

139.5

127.0

119.7

142.6

130.1

122.8

SHC

69.3

86.3

97.5

72.7

91.6

104.1

75.8

96.7

110.3

KW

36.0

35.0

34.3

36.3

35.3

34.6

36.5

35.5

34.9

TC

131.2

119.7

112.4

134.3

122.8

115.5

136.4

124.9

118.7

SHC

67.5

84.3

95.5

70.8

89.6

102.0

73.9

94.6

108.3

KW

38.6

37.3

36.5

38.9

37.6

36.8

39.1

37.9

37.2

TC

126.0

114.5

108.3

129.1

117.6

111.4

131.2

119.7

113.5

SHC

65.5

82.3

93.4

68.8

87.5

99.8

71.9

92.5

106.2

KW

41.0

39.5

38.5

41.3

39.9

39.0

41.6

40.2

39.3

- TOTAL CAPACITY (KW)


- SENSIBLE HEAT CAPACITY (KW)
- COMPRESSOR MOTOR POWER INPUT (KW)

PERFORMANCE DATA
50BP - 520 COOLING CAPACITY
LEAVING
CONDENSER

EVAPORATOR AIR (L/S)/B.F.

WATER

4700/0.09

6500/0.12

TEMPERATURE

EVAPORATOR AIR ENTERING WET BULB (C)

(C)
30

35

40

45

TC
SHC
KW

7710/0.14

22.0

19.5

17.0

22.0

19.5

17.0

22.0

19.5

17.0

TC

161.9

148.4

135.9

171.0

156.9

144.6

174.4

160.1

148.1

SHC

76.3

91.4

105.9

84.4

105.2

124.7

89.3

113.6

136.0

KW

40.0

39.0

38.0

40.8

39.8

39.0

41.2

40.2

39.4

TC

155.0

141.6

130.0

163.3

149.6

138.0

166.1

152.4

141.2

SHC

73.5

88.7

103.0

81.5

102.2

121.6

86.3

110.6

132.7

KW

43.8

42.6

41.4

44.8

43.6

42.4

45.0

44.0

43.0

TC

148.1

135.2

124.1

155.2

142.3

131.4

157.8

144.8

134.4

SHC

70.8

85.8

100.1

78.6

99.2

118.5

83.4

107.5

129.2

KW

47.4

45.8

44.4

48.6

47.2

45.8

49.0

47.6

46.4

TC

141.0

128.7

117.9

147.2

64.5

124.4

149.4

137.0

127.6

SHC

67.9

83.0

97.1

75.6

96.2

115.2

80.4

104.4

125.4

KW

51.0

49.2

47.6

52.2

50.6

49.0

52.8

51.2

49.6

- TOTAL CAPACITY (KW)


- SENSIBLE HEAT CAPACITY (KW)
- COMPRESSOR MOTOR POWER INPUT (KW)

16

PERFORMANCE DATA
50BP - 680 COOLING CAPACITY
LEAVING
CONDENSER

EVAPORATOR AIR (L/S)/B.F.

WATER

5000/0.05

7500/0.09

TEMPERATURE
(C)
30

35

40

45

TC
SHC
KW

10000/0.12

EVAPORATOR AIR ENTERING WET BULB (C)


22.0

19.5

17.0

22.0

19.5

17.0

22.0

19.5

17.0

TC

203.2

189.3

176.8

216.7

202.1

190.0

224.1

209.5

199.3

SHC

86.2

101.9

116.6

95.9

118.5

139.4

104.1

133.0

156.3

KW

42.2

41.6

41.0

42.5

42.1

41.6

42.7

42.3

42.0

TC

201.4

187.6

175.1

214.1

199.7

188.1

221.1

206.9

197.4

SHC

83.8

99.5

114.2

93.4

116.0

136.7

101.6

130.4

151.9

KW

46.4

45.6

44.6

47.1

46.3

45.6

47.4

46.7

46.2

TC

199.2

185.5

173.2

211.5

197.2

185.8

218.0

204.0

195.8

SHC

81.5

97.0

111.7

91.1

113.4

133.8

99.1

127.6

146.5

KW

50.6

49.4

48.2

51.5

50.4

49.4

51.9

51.0

50.3

TC

196.3

182.7

170.6

207.9

193.8

182.9

214.0

200.4

193.6

SHC

78.7

94.3

108.9

88.2

110.5

130.3

96.3

124.5

140.2

KW

55.1

53.5

51.9

56.2

54.8

53.5

56.8

55.5

54.8

TOTAL CAPACITY (KW)


SENSIBLE HEAT CAPACITY (KW)
COMPRESSOR MOTOR POWER INPUT (KW)

PERFORMANCE DATA
50BP - 900 COOLING CAPACITY
LEAVING
CONDENSER

EVAPORATOR AIR (L/S)/B.F.

WATER

8000/0.03

9500/0.04

TEMPERATURE

EVAPORATOR AIR ENTERING WET BULB (C)

(C)
30

35

40

45

TC
SHC
KW

11000/0.05

22.0

19.5

17.0

22.0

19.5

17.0

22.0

19.5

17.0

TC

281.4

261.5

244.2

289.1

268.9

252.0

294.7

274.5

258.5

SHC

123.1

148.9

172.9

129.2

159.5

187.2

134.9

169.4

186.6

KW

60.2

58.9

57.6

60.6

59.4

58.2

60.9

59.8

58.7

TC

276.8

257.3

240.2

284.2

264.3

247.8

289.5

269.7

254.3

SHC

119.8

145.6

169.5

125.9

156.1

183.6

131.7

166.0

195.9

KW

65.3

63.7

62.1

65.9

64.3

62.8

66.3

64.8

63.4

TC

272.0

252.7

236.2

278.8

259.2

243.4

283.8

264.6

249.6

SHC

116.7

142.3

166.0

122.7

152.7

179.7

128.4

162.5

191.6

KW

70.4

68.4

66.5

71.1

69.1

67.3

71.5

69.7

68.0

TC

266.0

247.2

231.0

272.5

253.4

238.2

277.2

258.3

244.3

SHC

113.0

138.5

162.1

119.0

148.8

175.4

124.7

158.6

186.2

KW

75.3

72.9

70.7

76.1

73.7

71.7

76.6

74.4

72.5

TOTAL CAPACITY (KW)


SENSIBLE HEAT CAPACITY (KW)
COMPRESSOR MOTOR POWER INPUT (KW)

17

FAN PERFORMANCE
1. The fan performance curves for high, medium, low speed and unit external static pressure are
based on dry coil and clean filters.
2. Do not operate left of operation limit line.

EXTERNAL STATIC PRESSURE (Pa)

50BP080

AIR QUANTITY (L/S)

EXTERNAL STATIC PRESSURE (Pa)

50BP100

AIR QUANTITY (L/S)

18

FAN PERFORMANCE
1. The fan performance curves are based on wet coil and clean filters.
2. The kW values denote fan motor nominal output.
3. Use curves within the ranges shown. Do not exceed the ranges.

EXTERNAL STATIC PRESSURE (Pa)

50BP160

AIR QUANTITY (L/S)

EXTERNAL STATIC PRESSURE (Pa)

50BP200

AIR QUANTITY (L/S)

19

FAN PERFORMANCE
1. The fan performance curves are based on dry coil and clean filters.
2. The kW values denote fan motor nominal output.
3. Use curves within the ranges shown. Do not exceed the ranges.

EXTERNAL STATIC PRESSURE (Pa)

50BP260

AIR QUANTITY (L/S)

EXTERNAL STATIC PRESSURE (Pa)

50BP340

AIR QUANTITY (L/S)

20

FAN PERFORMANCE
1. The fan performance curves are based on wet coil and clean filters.
2. The kW values denote fan motor nominal output.
3. Use curves within the ranges shown. Do not exceed the ranges.

50BP450
400
1200 RPM
350

EXTERNAL STATIC PRESSURE (Pa)

300
1100 RPM

7.5 Kw

250

200

1000 RPM

150

900 RPM
100

800 RPM

50

0
4400

4500

4600

4700

4800

4900

5000

5100

AIR QUANTITY (L/S)

EXTERNAL STATIC PRESSURE (Pa)

50BP520

AIR QUANTITY (L/S)

21

5200

5300

5400

5500

5600

5700

5800

FAN PERFORMANCE
1. The fan performance curves are based on wet coil and clean filters.
2. The kW values denote fan motor nominal output.
3. Use curves within the ranges shown. Do not exceed the ranges.

50BP680

700

900

EXTERNAL STATIC PRESSURE (Pa)

600

500

1,0

00

RPM

800

RP

RPM

400

700

300

RP

200

15

.0

.0

11

100

KW

KW

0
5

10

AIR QUANTITY (L/S) x 1000

50BP900

EXTERNAL STATIC PRESSURE (Pa)

700

600

1000

RPM

500

400

900 R

PM

300

800 R

PM

18.

5K

200

700

15.

RPM

0K

100

0
8

10

9
AIR QUANTITY (L/S) x 1000

22

11

Where:
TC = Total cooling capacity (kW)
Power Input = Compressor power input (kW)
Water Temp. Rise = Cond. leaving water temp. Cond. entering water temp. (C)

CONDENSER PERFORMANCE
Notes:
1. The following Condenser Pressure Drop values are
based on the fouling factor of 0.044 m 2 K/kW
2. Water flow rate can be calculated using the formula
below:
Water Flow (l/min)
=
TC + Power Input
Water Temp. Rise x 0.07

WATER PRESSURE DROP THRU CONDENSERS

EXTERNAL STATIC PRESSURE (Pa)

50BP080

AIR QUANTITY (L/S) x 1000

EXTERNAL STATIC PRESSURE (Pa)

50BP100

AIR QUANTITY (L/S) x 1000

23

CONDENSER PERFORMANCE

EXTERNAL STATIC PRESSURE (Pa)

50BP160

AIR QUANTITY (L/S) x 1000

EXTERNAL STATIC PRESSURE (Pa)

50BP200

AIR QUANTITY (L/S) x 1000

24

CONDENSER PERFORMANCE

EXTERNAL STATIC PRESSURE (Pa)

50BP260

AIR QUANTITY (L/S) x 1000

EXTERNAL STATIC PRESSURE (Pa)

50BP340/680

AIR QUANTITY (L/S) x 1000

25

CONDENSER PERFORMANCE

50BP450/900
25

WATER PRESSURE DROP (kPa)

20

15

10

0
300

320

340

360

380

400

420

440

460

480

500

520

WATER FLOW (L/MIN)


NOTE: 50BP900 has two nos. of similar condensers. Above condenser rating is based on ONE no. of condenser only.

WATER PRESSURE DROP (kPa)

50BP520

WATER FLOW (L/MIN)

26

540

ELECTRICAL WIRING DIAGRAMS

50BP080 & 50BP100 WIRING DIAGRAM


27

50BP160 & 50BP200 WIRING DIAGRAM


28

50BP260, 50BP340 & 50BP450 WIRING DIAGRAM (auto transformer start)


29

50BP260, 50BP340 & 50BP450 WIRING DIAGRAM (part winding start)


30

50BP520, 50BP680 & 50BP900 WIRING DIAGRAM (part winding start)


31

50BP680 & 50BP900 WIRING DIAGRAM (auto transformer start)


32

50BP680 & 50BP900 WIRING DIAGRAM (part winding start)


33

GUIDE SPECIFICATIONS
GENERAL

CONDENSER

1.1 Unit shall be single-package vertical type and shall


include self-contained water cooled condenser(s).

4.1 Water cooled condenser shall be shell in tube type. It


shall be equipped with a pressure relief device and
liquid line shut off valve (50BP260 to 50BP900).

1.2 Total cooling capacity of the unit shall be _____ kW,


or greater at conditions of ________ l/s evaporator air
entering unit at ________ C wet bulb temperature.
Total sensible capacity shall be ____________ kW or
greater with _______ C dry-bulb temperature at the
above conditions.

4.2 Finned tubes shall be seamless with no interior


joints. Threaded pipe connections shall be provided
for water supply and return lines. Each unit shall
contain a full operating refrigerant charge.
EVAPORATOR COIL

1.3 Water cooled condenser shall maintain __________


saturated condensing temperature when supplied
with _______ l/min of _______ C water at a ______
water fouling factor.

5.1 Evaporator coil shall be of non-ferrous construction


with aluminium plate fins mechanically bonded to
seamless copper tubing.

1.4 Maximum water pressure drop for the condenser(s)


at these conditions shall be _____ kPa.

5.2 Coils shall be tested at 2760 kPag air pressure while


submerged in water.

COMPRESSOR(S)

5.3 Coil shall be fed by capillary tubes (50BP080 to


50BP200) and thermostatic expansion valve
(50BP260 to 50BP900).

2.1 50BP080 to 50BP200 shall be equipped with fully


hermetic reciprocating compressor(s).
50BP260 to 50BP900 shall be equipped with
serviceable semi hermetic reciprocating compressor.

EVAPORATOR AIR FAN


6.1 Evaporator air fan shall be capable of delivery
__________ l/s of air with an external static pressure
of _________ Pa or greater.

2.2 Compressor(s) shall be mounted with suitable


vibration isolators, crankcase heaters, strainer
(50BP080 to 50BP200), filter drier, discharge shut
off valves (50BP260 to 50BP900) and shall be
located in a sound attenuating compartment within
the cabinet.

6.2 Evaporator air fan shall be centrifugal forward


curved and direct driven (50BP080 and 50BP100) or
belt driven (50BP160 to 50BP900) by a motor of
nominal _______ kW when operating at ______ rpm.

2.3 Compressor (50BP260 to 50BP450) is equipped


with unloader for 2 steps capacity control.

6.3 Motor shall be factory supplied with 3 speed direct


driven motor (50BP080 and 50BP100) or 1 speed
TEFC type motor (50BP160 to 50BP900).

2.4 Power input to the compressor motor(s) shall not


exceed _______ kW at the conditions specified.

ACCESSORY
CABINET
7.1 Optional air plenum for free blow option is available
for 50BP080 and 50BP100.

3.1 Panels shall be factory painted with durable oven


cured polyester based powder paint, which can
withstand 500 hours of salt spray test and in
accordance with ASTM B117.

7.2 Optional 2" filter media is available for 50BP680 and


50BP900.

3.2 Unit sections shall be insulated with 25.4 mm


polyurethene insulations to prevent sweating and to
muffle sound.
3.3 The unit dimensions shall be __________ mm wide,
_________ mm deep and _________ mm high.
3.4 A self-contained filter frame for use with standard
permanent/throwaway filters of ______ mm x ______
mm x ______ mm shall be located inside of the
cabinet (50BP080 to 50BP200) or at the back of the
cabinet (50BP260 to 50BP900). Filters shall be
factory supplied.

34

MEMO

35

MEMO

36

Carrier
International
Sdn. Bhd.
Malaysia

Carrier International Sdn. Bhd. (3385-T)


Lot 4, Jalan P/6, 43650 Bandar Baru Bangi,
Selangor, Malaysia.
Tel: 03-8925 8001
Fax: 03-8925 3578

REV. 2 50BP
5

2003

Manufacturer reserves the right to discontinue, or


change at any time, specifications or designs
without notice and without incurring obligations.

50BP-E03-7PD supercedes 50BP-D02-6PD


37