Sei sulla pagina 1di 12

No.

Date Revision By
Date: Project No: Scale: Drawing No.
Designed By:
Checked By:
1
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc.
The information contained herein has been compiled by Keystone Retaining Wall
Systems and to the best of our knowledge, accurately represents the Keystone
product use in the applications which are illustrated. This drawing is being
furnished for design guidance and estimating only. Final determination of the
suitability for the use contemplated and its manner of use are the sole
responsibility of the user. Structural and geotechnical design analysis shall be
performed by a qualified engineer.
Any party accepting this document does so in confidence and agrees that it shall
not be duplicated in whole or in part, nor disclosed to others without the consent
of Keystone Retaining Wall Systems, Inc.
cdm
1/10/00
Specialty Applications Title Sheet
Specialty Applications
for Keystone Walls
SHEET INDEX
Title Sheet Sheet 1
Soil Nail Facing Sheet 2
Rock/Shotcrete Facing Sheet 3
Manta Ray Anchor Wall Sheet 4
H-Pile Wall Facing Sheet 5
Sheet Pile Wall Facing Sheet 6
Concrete Wall Stairway Sheet 7
Interlocking Gravity Wall Sheet 8
Geofoam Wall Construction Sheet 9
Foundation Obstruction Sheet 10
Slip Joint Installation Sheet 11
In-situ Slip Joint Sheet 12
Keystone
Compac Units
Leveling Pad
Select
Backfill
32
1
Railing per Site Plans
Bond Breaker/Exp Jt
7.5'
6.5'
Existing
Concrete
Wall
2" Coping
Finished Grade
6" Thick Concrete Slab
Exp Jt
Thickness varies at
steps and landings
3" Galvanized Pipe
#6 Pipe Anchors
Drill & Epoxy
into wall
SG200 Geogrid
Wrap Pipe and Return
Top of concrete wall
1
8
Leveling pad at elevations
and stations per layout plans
Keystone Compac Units
2' Typ.
Keystone Cap Unit
Soil Failure Plane
Stiff Firm Soil
5
Finished Grade
No. Date Revision By
Date: Project No: Scale: Drawing No.
Designed By:
Checked By:
2
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc.
The information contained herein has been compiled by Keystone Retaining Wall
Systems and to the best of our knowledge, accurately represents the Keystone
product use in the applications which are illustrated. This drawing is being
furnished for design guidance and estimating only. Final determination of the
suitability for the use contemplated and its manner of use are the sole
responsibility of the user. Structural and geotechnical design analysis shall be
performed by a qualified engineer.
Any party accepting this document does so in confidence and agrees that it shall
not be duplicated in whole or in part, nor disclosed to others without the consent
of Keystone Retaining Wall Systems, Inc.
cdm
1/10/00
Specialty Applications
#4 Rebar
Typical Plan View
Soil
Anchors
5' c/c
Keystone Compac Units
Flowable
Concrete Fill Shotcrete
Soil Nail Facing
Typical Wall Elevation
Footing Steps
1/2" Expansion Joint Material
(50' c/c Maximum)
Geogrid
Top of Wall Steps
Typical Soil Nail/Anchor Section
1
8
Leveling Pad at Elevations
and Stations per Layout Plans
6" Perforated PVC Collector
Pipe to Underdrai n System
#57 Stone Wrapped in Geotextile
Soil Nail/Anchor System
(design by others)
5' Typ.
Temporary Shotcrete & Mesh Facing
Support System with Drainage.
(design by others)
Keystone Compac Units
Flowable Concrete Fill
f'c = 500 psi - 2' Lifts
2'
Vertical #4 Rebar @ 2.5' c/c
Geogrid - 2' Vertical c/c
Extend to Shotcrete Between rebar
Horizontal #4 Rebar @ 2.5' c/c
(at anchor locations)
See Anchorage Detail
1' Nominal
(6" min)
Keystone Cap Unit
#10 Grade 60 Anchor
6" x 6" x 1/2" Steel Plate
(2) - Nuts to Secure Plate
#10 bar-Extended Threads
#4 Rebar
Flowable Concrete Fill
Keystone
Compac
Unit
Geogrid
Typical Anchorage Detail
Drainage Net
Geogrid
Soil
Anchors
5' c/c
Finished Grade
Finished Grade
Draingage Net
(design by others)
No. Date Revision By
Date: Project No: Scale: Drawing No.
Designed By:
Checked By:
3
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc.
The information contained herein has been compiled by Keystone Retaining Wall
Systems and to the best of our knowledge, accurately represents the Keystone
product use in the applications which are illustrated. This drawing is being
furnished for design guidance and estimating only. Final determination of the
suitability for the use contemplated and its manner of use are the sole
responsibility of the user. Structural and geotechnical design analysis shall be
performed by a qualified engineer.
Any party accepting this document does so in confidence and agrees that it shall
not be duplicated in whole or in part, nor disclosed to others without the consent
of Keystone Retaining Wall Systems, Inc.
cdm
1/10/00
Specialty Applications
Typical Plan View
Rock
Anchors
6' c/c
Keystone Standard Units
Rock
Rock/Shotcrete Facing
Typical Wall Elevation
#5 Rebar
Top of Wall Steps
Typical Rock Facing Section
1
32
6" Perforated PVC Collector Pipe
Unit Drainage Fill
Rock Anchor System
(design by others)
4' c/c (Max)
Keystone Standard Units
1.75'
See Concrete Beam Detail
6"
Keystone Cap Unit
4" x 4" x 1/4" Steel Plate with
(2) - Nuts to Secure Plate
Keystone
Standard
Unit
Typical Concrete Beam Detail
Keystone Standard
Unit with Tail Cutoff
Rock Bolt or Rock Anchor
(length and spacing determined
by design engineer)
(4) - #5 Rebar
Rock
Keystone Standard
Unit with Tail Cutoff
Keystone Standard
Unit with Tail Cutoff
1/2" Exp Joint in Beam
@ 18' c/c - Stop rebar
Concrete Beam
(min 2" into unit above and
below , f'c -4000 psi)
Unit Drainage Fill
Unit Drainage Fill
Rock Bolt Patttern (4' x 6' staggered)
Limits of Concrete Beam
Protect Exposed Anchor from Corrosion.
(galvanize, cold tar epoxy, grouted sleeve)
Footing Steps
Soil
Leveling Pad at Elevations
and Stations per Layout Plans
Finished Grade
Joint in Concrete Beam
Finished Grade
No. Date Revision By
Date: Project No: Scale: Drawing No.
Designed By:
Checked By:
4
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc.
The information contained herein has been compiled by Keystone Retaining Wall
Systems and to the best of our knowledge, accurately represents the Keystone
product use in the applications which are illustrated. This drawing is being
furnished for design guidance and estimating only. Final determination of the
suitability for the use contemplated and its manner of use are the sole
responsibility of the user. Structural and geotechnical design analysis shall be
performed by a qualified engineer.
Any party accepting this document does so in confidence and agrees that it shall
not be duplicated in whole or in part, nor disclosed to others without the consent
of Keystone Retaining Wall Systems, Inc.
cdm
1/10/00
Specialty Applications
Typical Plan View
Manta Ray Anchor Facing
Typical Wall Elevation
Footing Steps
Typical Manta Ray Anchor Section
1
8
Leveling Pad at Elevations
and Stations per Layout Plans
Keystone Compac Units
2' Typ.
Keystone Cap Unit
Unit Drainage Fill
Keystone
Compac
Unit
Typical Connector Detail
Manta Ray
Anchors
Keystone Compac Units
Geogrid 3" Galvanized Pipe
Stiff Firm Soil
Galvanized
Pipe Loop
Connector
Unit Drainage Fill
Geogrid (LTDS >1200 plf)
Manta Ray Anchor
3" Galvanized Pipe, Sch 40
Galvanized Pipe Loop Connector
Soil Failure Plane
Stiff Firm Soil
3/4" Galv. CTB Rod
5
6' c/c
Galvanized Pipe,
Loop Connector and
Manta Ray Anchors
(staggered installation)
3" Galvanized Pipe
Top of Wall Steps
Finished Grade Finished Grade
Threaded Pipe Coupling
No. Date Revision By
Date: Project No: Scale: Drawing No.
Designed By:
Checked By:
5
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc.
The information contained herein has been compiled by Keystone Retaining Wall
Systems and to the best of our knowledge, accurately represents the Keystone
product use in the applications which are illustrated. This drawing is being
furnished for design guidance and estimating only. Final determination of the
suitability for the use contemplated and its manner of use are the sole
responsibility of the user. Structural and geotechnical design analysis shall be
performed by a qualified engineer.
Any party accepting this document does so in confidence and agrees that it shall
not be duplicated in whole or in part, nor disclosed to others without the consent
of Keystone Retaining Wall Systems, Inc.
cdm
1/10/00
Specialty Applications
Typical Pile & Lagging Wall Section
1
32
Leveling pad at elevations
and stations per layout plans
Keystone Compac Units
2'
1' nominal
Keystone Cap Unit
Unit Drainage Fill
4" Perforated PVC Collector Pipe
Steel H Piling
Driven or Augered
Finished Grade
Timber Lagging as Req'd
2.67' c/c (Max)
3" Galvanized Pipe
& Welded Pipe Loop
See Connector Detail
Typical Wall Elevation
Top of Wall Steps
Finished Grade
Keystone Compac Units
Geogrid Steel H Piles Timber Lagging
6' to 8' c/c
Welded Pipe Loops 3" Galvanized Pipe
Unit Drainage Fill
Typical Plan View
Unit Drainage Fill
Keystone
Compac
Unit
Geogrid (LTDS >1200 plf)
3" Galvanized Pipe
Welded Pipe Loop -
#6 Rebar or
1/4" x 1.5" Bar Stock
Steel H Piling
Timber Lagging as Req'd
Typical Connector Detail
Soldier Pile Facing
No. Date Revision By
Date: Project No: Scale: Drawing No.
Designed By:
Checked By:
6
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc.
The information contained herein has been compiled by Keystone Retaining Wall
Systems and to the best of our knowledge, accurately represents the Keystone
product use in the applications which are illustrated. This drawing is being
furnished for design guidance and estimating only. Final determination of the
suitability for the use contemplated and its manner of use are the sole
responsibility of the user. Structural and geotechnical design analysis shall be
performed by a qualified engineer.
Any party accepting this document does so in confidence and agrees that it shall
not be duplicated in whole or in part, nor disclosed to others without the consent
of Keystone Retaining Wall Systems, Inc.
cdm
1/10/00
Specialty Applications
Typical Plan View
Keystone Compac Units
Typical Wall Elevation
Sheet Pile Facing
Geogrid Sheet Piling
6' to 8' c/c
Welded Pipe Loops 3" Galvanized Pipe
Top of Wall Steps
Typical Sheet Piling Wall Section
1
32
Leveling Pad at Elevations and
Stations per Layout Plans
Keystone Compac Units
2'
1' nominal
Keystone Cap Unit
Unit Drainage Fill
4" Perforated PVC Collector Pipe
Steel Sheet Piling
PZ22/PZ27 Typical
(design by others)
Finished Grade
Unit Drainage Fill
Keystone
Compac
Unit
Geogrid
3" Galvanized Pipe
Welded Pipe Loop
#6 Rebar or
1/4" x 1.5" Bar Stock
Steel Sheet Piling
Typical Connector Detail
2.67' c/c (Max)
3" Galvanized Pipe
& Welded Pipe Loop
Finished Grade
See Connector Detail
No. Date Revision By
Date: Project No: Scale: Drawing No.
Designed By:
Checked By:
7
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc.
The information contained herein has been compiled by Keystone Retaining Wall
Systems and to the best of our knowledge, accurately represents the Keystone
product use in the applications which are illustrated. This drawing is being
furnished for design guidance and estimating only. Final determination of the
suitability for the use contemplated and its manner of use are the sole
responsibility of the user. Structural and geotechnical design analysis shall be
performed by a qualified engineer.
Any party accepting this document does so in confidence and agrees that it shall
not be duplicated in whole or in part, nor disclosed to others without the consent
of Keystone Retaining Wall Systems, Inc.
cdm
1/10/00
Specialty Applications
7' 7' 9 @ 11" = 8.25' 9 @ 11" = 8.25' 9 @ 11" = 8.25'
10 @ 7 1/2"
= 6.25'
10 @ 7 1/2"
= 6.25'
10 @ 7 1/2"
= 6.25'
Geogrid Depth to Concrete Wall 7.5' 7.5' To Pipe Anchoring System
3" Galvanized Pipe #6 Pipe Anchors
6' c/c
Top of existing concrete wall
Elevation - Front Face
46'
Plan View - Front Face
Existing Concrete Wall
Keystone
Compac Units
Leveling Pad
Select
Backfill
32
1
Railing per Site Plans
Bond Breaker/Exp Jt
Typical Section - Second Landing
7.5'
6.5'
Existing
Concrete
Wall
2" Coping
Finished Grade
6" Thick Concrete Slab
Exp Jt
Thickness varies at
steps and landings
3" Galvanized Pipe
#6 Pipe Anchors
Drill & Epoxy
into wall
Geogrid
Wrap Pipe and Return
Pipe Anchor Detail
5"-6"
5"-6"
3" Galvanized Pipe
(use threaded couplers)
#6 Rebar Pipe Anchors
Bend as shown.
Install per epoxy manufacturer.
Coat with cold tar epoxy
after installation.
6 5/8"
Hilti HVA Epoxy Adhesive System
(1" hole for #6 rebar)
7.5' Top of Wall
8.2' Bottom of Wall
for 1:32 Batter
Top of concrete wall
Stairway Facing/ Concrete Wall
Stratagrid SG200
Key
Cut Blocks
Pipe Anchors/Pi pe
7'
No. Date Revision By
Date: Project No: Scale: Drawing No.
Designed By:
Checked By:
8
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc.
The information contained herein has been compiled by Keystone Retaining Wall
Systems and to the best of our knowledge, accurately represents the Keystone
product use in the applications which are illustrated. This drawing is being
furnished for design guidance and estimating only. Final determination of the
suitability for the use contemplated and its manner of use are the sole
responsibility of the user. Structural and geotechnical design analysis shall be
performed by a qualified engineer.
Any party accepting this document does so in confidence and agrees that it shall
not be duplicated in whole or in part, nor disclosed to others without the consent
of Keystone Retaining Wall Systems, Inc.
cdm
1/10/00
Specialty Applications
Keystone
Standard Units
Cap Unit
Leveling Pad
Unit Drainage Fill
Finished Grade
1
8
PL
5'
Limits of excavation
Interlock units where
required on elevation
1'
Low Permeable Soil
Typical Interlocked Wall Section
Typical Detail
Front Units
with Pins
Standard Units 1" setback - Interlocked
Typical Wall Elevation
Unit Drainage Fill
Back Units
with no Pins
Interlocking Standard Units
Standard Units 1" setback
Interlocked Standard Units
Top of Wall Steps
Footing Steps
Typical Plan View
Keystone Standard Units
Stiff Firm Soil
Unit Drainage Fill
Finished Grade
Finished Grade
No. Date Revision By
Date: Project No: Scale: Drawing No.
Designed By:
Checked By:
9
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc.
The information contained herein has been compiled by Keystone Retaining Wall
Systems and to the best of our knowledge, accurately represents the Keystone
product use in the applications which are illustrated. This drawing is being
furnished for design guidance and estimating only. Final determination of the
suitability for the use contemplated and its manner of use are the sole
responsibility of the user. Structural and geotechnical design analysis shall be
performed by a qualified engineer.
Any party accepting this document does so in confidence and agrees that it shall
not be duplicated in whole or in part, nor disclosed to others without the consent
of Keystone Retaining Wall Systems, Inc.
cdm
1/10/00
Specialty Applications
Top of Wall
Top of Sidewalk Profile
Bottom of Wall
Wing
Wall
Bottom of Geofoam Footing Step
Barrier Parapet
Geofoam Blocks (32" x 4' x 8' Typ.)
Geogrid
Geogrid
Geogrid
Geogrid
Elevation - Front Face
Keystone Standard Unit
Keystone Cap Unit
Keystone Compac Unit
Geogrid
1/2"! pins
Typical Section
Keystone/Geofoam Wall
Typical Wall Plan
12" Concrete Slab
Geogrid
Gravel Borrow
Wing Wall
Roadway
Keystone Standard Unit
Geogrid Reinforced
Wall Section
Geofoam
Geofoam
Geofoam
Base Leveling Pad
No. Date Revision By
Date: Project No: Scale: Drawing No.
Designed By:
Checked By:
10
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc.
The information contained herein has been compiled by Keystone Retaining Wall
Systems and to the best of our knowledge, accurately represents the Keystone
product use in the applications which are illustrated. This drawing is being
furnished for design guidance and estimating only. Final determination of the
suitability for the use contemplated and its manner of use are the sole
responsibility of the user. Structural and geotechnical design analysis shall be
performed by a qualified engineer.
Any party accepting this document does so in confidence and agrees that it shall
not be duplicated in whole or in part, nor disclosed to others without the consent
of Keystone Retaining Wall Systems, Inc.
cdm
1/10/00
Specialty Applications
C
L
Pier Foundation
Concrete Pier
1
1
5' Dia
Foundation Obstruction
4" Galv Pipe - 6' long
3/4" Galv CTB Bar - 7' Long
Galv Nut & Washers
Design Geogrid Level
Concrete Pier
4" Galv Pipe
5' Lap
4' Typ
Keystone Compac Units
3/4" Galv CTB TieRod
Geogrid - Wrap pipe
and return to wall
Wall Elevation @ Pier Wall Section @ Pier
Wall Plan @ Pier
Keystone Compac Units
6' Wide Geogrid
Unit Drainage Fill
No. Date Revision By
Date: Project No: Scale: Drawing No.
Designed By:
Checked By:
11
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc.
The information contained herein has been compiled by Keystone Retaining Wall
Systems and to the best of our knowledge, accurately represents the Keystone
product use in the applications which are illustrated. This drawing is being
furnished for design guidance and estimating only. Final determination of the
suitability for the use contemplated and its manner of use are the sole
responsibility of the user. Structural and geotechnical design analysis shall be
performed by a qualified engineer.
Any party accepting this document does so in confidence and agrees that it shall
not be duplicated in whole or in part, nor disclosed to others without the consent
of Keystone Retaining Wall Systems, Inc.
cdm
1/10/00
Specialty Applications
Front Elevation
Geogrid Layers Typical
11" min Space
Even Course
Three Unit Compac Assembly
Grouted with #4 bar
Odd Course
12"
18"
Cut in Half
Trim to Fit
Compac Unit Cut Compac Unit
Slip Joint Installation
Plan View
No. Date Revision By
Date: Project No: Scale: Drawing No.
Designed By:
Checked By:
12
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc.
The information contained herein has been compiled by Keystone Retaining Wall
Systems and to the best of our knowledge, accurately represents the Keystone
product use in the applications which are illustrated. This drawing is being
furnished for design guidance and estimating only. Final determination of the
suitability for the use contemplated and its manner of use are the sole
responsibility of the user. Structural and geotechnical design analysis shall be
performed by a qualified engineer.
Any party accepting this document does so in confidence and agrees that it shall
not be duplicated in whole or in part, nor disclosed to others without the consent
of Keystone Retaining Wall Systems, Inc.
cdm
1/10/00
Specialty Applications
MR-88 Manta Ray Drive
Anchor and 6' Threadbar
9.5"
11"
8"
12"
18"
1" Hole for threadbar
2" Recess for Nut and Washer
Cut Off
Three Cut Units One Cut Unit with Hole
12" cut into
existing wall
Odd Course
Even Course
Three Unit Assembly - Grouted with #3 bars
Plan View
3 Unit Assembly
Anchored 3 Unit Assembly
In-Situ Slip Joint
Installation
1. Cut out wall in 3-4 unit segments.
2. Drive anchor into backfill and lock.
3. Install three unit slip joint segment.
4. Repeat as required.

Potrebbero piacerti anche