Sei sulla pagina 1di 6

A4 US

US
A4
US A4
US
A4
A4 US
US
A4
US
A4
A4 US
Redefining Flow Control
Pneumatic and Hydraulic Actuators
for multi-turn applications
Twin Power Range
A4 US
US
A4
US A4
US
A4
A4 US
US
A4
US
A4
A4 US
2
Rotork Actuators Quality Controlled
Twin Power Multi-turn Actuators
In the 50 years since the company was founded,
Rotork has become the standard for excellence
in the field of valve and damper automation for
the oil, gas, power, water and waste treatment
industries around the world.
As established leaders in actuation technology, we owe our
success to a commitment to quality at every stage, and at
every level, of Rotorks operations.
At the heart of the company is an exceptional workforce the
highly trained, forward thinking engineers, technicians, and
sales support staff who each play a crucial role in maintaining
Rotorks unrivaled reputation for innovation, reliability and first
class after sales support.
With fluid power factories in England, Germany, Italy,
Sweden and the United States, and additional Rotork Centres
of Excellence located around the globe, we are able to
offer creative solutions and design systems for virtually any
application from sub-sea hydraulics to the most sophisticated
yet simple fluid power control system.
Contact Rotork for your operational or safety application
requirements. We will work with you from conception,
to design, to manufacture, to installation, and finally to
maintenance and service support.
The Twin Power is a series of pneumatic and
hydraulic actuators for multi-turn applications.
It is a robust actuator with a recognised
reputation in the oil & gas and other process
industries that has been proven in installations
ranging from the challenging cold of the North
Sea to the heat and humidity of Indonesia.
The name is derived from the actuators unique design that
enables it to produce two output torque values a constant
run output with increased output (up to 50% more) start
output in both directions of rotation*. There are both one and
two motor designs available with four motor sizes of either
diaphragm or piston type providing output up to 800 Nm
(7,080 lbf.in). If necessary, output can easily be increased by
means of an intermediate gearbox.
Twin Powers compact size is often a significant benefit due to
the space constrains common to process plant and offshore
applications. It is easily mounted on either installed or new
valves, regardless of type, manufacture, or drive shaft design.
It can be operated locally or remotely via pneumatic or
solenoid valves and a manual handwheel is provided on all
units. Three micro-switches are included to indicate open,
close and run conditions. Optionally, the actuator can be
supplied with a pneumatic or electric position transmitter.
A4 US
US
A4
US A4
US
A4
A4 US
US
A4
US
A4
A4 US
3
Redefining Flow Control
Inside the Twin Power Actuator
Output Torque Diagram
START START
RUN RUN
O
u
t
p
u
t
Valve Opens Valve Closes
*All hydraulic powered units and pneumatic units for choke valve applications have no indicator bridge or twin power mechanism.
Therefore, they provide a constant torque output rather than the two-stage output provided by standard pneumatically powered units.
Start torque position
Run torque position
Actuator Housing
cast iron.
Indicator Bridge
for electric or pneumatic
indication.
Motor
The Twin Power is available
with either one (model 114) or two
(model 214) motors. The motors
come in four sizes in either piston
or diaphragm executions.
Twin Power Mechanism*
Increased start torque is achieved by
positioning the feed mechanism to
increase leverage, and therefore available
torque, (with reduced travel per step).
After a few turns, the lever automatically
returns to the run position.
Cylinder
for switching between open and close.
Control Valve
with air connection
(pnuematic units only).
A4 US
US
A4
US A4
US
A4
A4 US
US
A4
US
A4
A4 US
4
Dimensions Pneumatic
View A-A
Hc 140
20
120
o
210 190
8 x 20
Hc 88
M8 x 20
120
o
25
o
M
100
430
1/4 (BSP)
75
100
160
M10 x 24
81,3
H
160 270
430
400
8 x 20
M
Hc 88
M8 x 20
120
o
25
o
1/4 (BSP)
125
A
A
25 75
160
H
118
25
A
A
65
Type 114
Type 214
A4 US
US
A4
US A4
US
A4
A4 US
US
A4
US
A4
A4 US
5
Redefining Flow Control
Every Rotork Fluid Systems actuator is built to provide long
and efficient service with minimum maintenance. The design,
engineering and materials used in their construction ensure
optimum performance even in the harshest environments.
Operating Pressure: Up to 8 bar (116 psi)
Type: 114: One motor
214: Two motors
Torque Output: Type 114: 20-400 Nm
Type 214: 40-800 Nm
Steps Per Turn: 27*
Speed of Operation: Single step operation with
reciprocating or SOV pulse time
1.5 sec. on 1.5 sec off*
Operating Media: Air or inert gas.
Weight: Type 114: 25-40 kg**
Type 214: 333-50 kg**
Temperature Range:
Standard: -30 to +80 C (-22 to +176 F)
High: 0 to +150 C (+32 to +302 F)
(with piston motor)
Valve Mounting Kit: Supplied either machined to suit
or blank, as requested.
* May be varied. Contact RFS
**Dependent upon motor size.
175
100
050
175 S
100 S
050 S
3.5
20
37
75
175
300
20
37
75
175
300
600
Model Minimum Maximum
Inductor Bridge Turn Limits
A
B
C
D
22
14
6
5
20
8
4
3
Motor
Size
114
(1 motor)
214
(2 motors)
Rotation Speed ( ) turns/min ca
Average Working Pressure (bar)
D
L
i
t
r
e
s

F
r
e
e

A
i
r

P
e
r

T
u
r
n
C
B
A
90
80
70
60
50
40
30
20
10
45
40
35
30
25
20
15
10
5
MOTOR TYPE
1 2 3 4 5 6 7
Air Requirements 114 214
114-12
114-22
114-32
214-12
214-22
214-32
A
B
C
D
-
-
120
220
320
130
230
330
125
150
175
195
-
-
Hub
Length
Motor
Size
H M
Dimensions
7
5
6
DIAPH
4
PISTON
Output Torque vs Motor Type
Torque Output (Nm)
S
u
p
p
l
y

P
r
e
s
s
u
r
e

(
b
a
r
)


0
0
100
200
200
400
300
600
400
800 214
D C B A
114
175
100
050
175 S
100 S
050 S
3.5
20
37
75
175
300
20
37
75
175
300
600
Model Minimum Maximum
Inductor Bridge Turn Limits
A
B
C
D
22
14
6
5
20
8
4
3
Motor
Size
114
(1 motor)
214
(2 motors)
Rotation Speed ( ) turns/min ca
Average Working Pressure (bar)
D
L
i
t
r
e
s

F
r
e
e

A
i
r

P
e
r

T
u
r
n
C
B
A
90
80
70
60
50
40
30
20
10
45
40
35
30
25
20
15
10
5
MOTOR TYPE
1 2 3 4 5 6 7
Air Requirements 114 214
114-12
114-22
114-32
214-12
214-22
214-32
A
B
C
D
-
-
120
220
320
130
230
330
125
150
175
195
-
-
Hub
Length
Motor
Size
H M
Dimensions
7
5
6
DIAPH
4
PISTON
Output Torque vs Motor Type
Torque Output (Nm)
S
u
p
p
l
y

P
r
e
s
s
u
r
e

(
b
a
r
)


0
0
100
200
200
400
300
600
400
800 214
D C B A
114
Dimensions
Hub
Length
H
Motor
Size
M
114-12 120 A 125
114-22 220 B 150
114-32 320 C 175
214-12 130 D 195
214-22 230 - -
214-32 330 - -
Inductor Bridge Turn Limits
Model Minimum Maximum
175 3.5 20
100 20 37
050 37 75
175 S 75 175
100 S 175 300
050 S 300 600
Rotation Speed (turns/min ca)
Motor
Size
114
(1 motor)
214
(2 motors)
A 22 20
B 14 8
C 6 4
D 5 3
Ensure that the number of valve turns
does not exceed the maximum number
of turns of the indicator bridge.
Air pressure 0.6 Mpa.
Faster speeds available. Consult RFS.
Technical Data Pneumatic
A4 US
US
A4
US A4
US
A4
A4 US
US
A4
US
A4
A4 US
Scan with your smart phone
for more information on
this product range
Redefining Flow Control
www.rotork.com
A full listing of our worldwide sales and
service network is available on our website.
Corporate Headquarters
Rotork plc
tel +44 (0)1225 733200
fax +44 (0)1225 333467
email mail@rotork.com
PUB025-002-00
Issue 05/10
Formerly F904E. All Rotork Fluid Systems actuators are manufactured under a third party
accredited ISO9001 quality assurance programme. As we are continually developing our
products, their design is subject to change without notice.
The name Rotork is a registered trademark. Rotork recognises all registered trademarks.
Published and produced in the UK by Rotork Fluid Systems. POWSH0713

Potrebbero piacerti anche