Sei sulla pagina 1di 1

Dr.K.

MURUGAPPAN 2/14/2014
Section details Name =
Depth,D = 304 mm
Width,B = 301 mm
Flange thk,tf = 17 mm tf = 17mm
Web thk,tw = 11 mm
b/T ratio = 7.58
d/t = 18 D = 304 mm
Section Area,A = 159 cm tw = 11 mm
Ixx = 23380 cm
4
Iyy = 7733 cm
4
rxx = 13.3 cm tf = 17mm
ryy = 7.57 cm
Steel strength,Py = 275 N/mm
Section classification
Axial Load,Pu = 65 kN
Strength,py = 265 N/mm Factor r
2
= 0.015427
= 1.018693
Flange Class = SEMI-COMPACT
Web class = SEMI-COMPACT
SEMI COMPACT
Calculations END CONDITIONS INDEX
Column Length,L = 5 m FIX,FIX = 0
End conditions = 2 PIN,PIN = 1
Effective length,Le = 7.5 m PARTIALLY FIXED = 2
Slenderness, xx = 56.39098 @ BOTH ENDS
yy = 99.0753 CANTILEVER = 3
Type of col. Section = H ( "I" or "H")
Type of curve
along xx-axis = b
along yy-axis = c LINEAR INTERPOLATION TABLE
Compressive strength based on the type of the curve xx pcx yy pcy
along xx-axis, pcx = 220.5865 N/mm 56 220 98 126
along yy-axis, pcy = 127.6129 N/mm 58 217 100 123
Compressive resistance of the column section
Along X-X axis = 3507.325 kN
Along Y-Y axis = 2029.046 kN
THE SECTION IS O.K SINCE SECTION CAPACITY>Pu
PROJECT MARYMOUNT CENTRE - CHAPEL BUILDING
PREPARED BY I. HARI AMUDHAN CHECKED BY DATE
UC - 305x305x118kg/m
B = 301mm

Potrebbero piacerti anche