TO THE DISSIMILAR METALS AND WITHOUT EXCEPTION ALL LEAKS OCCUR AT THE WELD JOINTS
Dissimilar metals are the chief cause of corrosion in metals (i.e. weld joints)
STRONGMETAL COLDWELD CERAMIC PUTTY (Blue Colour Cold Weld Compound) Weld joints
at all points to be sealed with the cold weld compound on the outer sides of all weld joints,
to prevent any ingress of moisture and corrosion. Making the tank last for as long as 10 years.
STRONGMETAL COLDWELD COMPOUNDS
INSTRUCTIONS FOR USE
PLEASE READ CAREFULLY BEFORE USE
ROUGHEN THE SURFACE (IF POSSIBLE ) WITH EMERY PAPER /WIRE BRUSH / FILE AND CLEAN THE
SURFACE.
DEGREASE THE SURFACE WITH A GOOD SOLVENT ( TRICHLOROETHYLENE / ACETONE/ CTC/ M.E.K.,
etc.)
STRONGMETAL SHOULD BE APPLIED ON TO A CLEAN DRY SURFACE ONLY.
(Except STRONGMETAL OL {ONLINE GRADE} which is suitable on oily & damp surfaces also.)
INDIRECT HEAT APPLIED ON TO THE REPAIRED AREA FACILITATES FASTER & MORE
COMPLETE CURE AND IS ADVISABLE FOR BETTER CHEMICAL & MECHANICAL RESISTANCE.
{A 100 W LAMP PLACED AT AROUND 10-12 inches of the repaired area for around 4-6 hours is
recommended}
STRONGMETAL BASE & HARDENER (ACTIVATOR) must be mixed 1:1 Ratio thoroughly with good
mixing.
Mix the two thoroughly in the Mixing Cup (provided) with the Mixing & Applicator Knife (provided) for
2-5 mins.
Apply onto the cleaned , abraded, degreased surface to be repaired ensuring that no air bubbles are
entrapped while application on the area to be repaired.
==========================================================================
FOR APPLICATION ON OLD/CHEMICAL CONTAMINATED SURFACE (For Best Results)
For application on Old / Chemical Contaminated surface please ensure that the surface is first
Neutralised.
If the contamination is of Acidic pH ,'neutralise with a Mild Alkali , rinse with water , dry , roughen the
surface and degrease the surface with a low Boiling Point Solvent before repair with STRONGMETAL.
If the contaminated surface is of Alkaline pH, neutralise with a Mild Acid and follow the procedure as
given above.
CLEANING
All tools used for application of STRONGMETAL must be cleaned with solvent immediately after use.
OPERATING SAFETY
Avoid eye and skin contact. In case of skin contact, wash with soap and water . In case of eye contact,
rinse thoroughly with water.
THIS TECHNICAL INFORMATION IS FOR ADVICE ONLY AND IS BELIEVED TO BE RELIABLE. AS THE USE
AND APPLICATION OF THE PRODUCT IS BEYOND OUR CONTROL IT IS THEREFORE THE USE'S
RESPONSIBILITY ONLY.
TYPICAL PHYSICAL PROPERTIES OF THE STRONGMETAL RANGE:
1. Shear 100 - 150 Kg/cm2. Compressive: 800-1400 Kg/cm2. Resis. Hydraulic Pres.: 150-250 Kg/cm2.
Peak Heat Rests.: 200-280 oC . Hardness: 80 - 85 Shore 'D'. Full Functional Strength ( at 30oC ) : 6
Hours. MIXING RATIO: Vol.- 10 : 1
3RWOLIHLQPLQV
3HDNWHPS
6KRUH' $GKHVLYH
$W&>
5HVLVWDQFHLQ& KDUGQHVV 6KHDU
JPVPL[HGPDVV@
%\WHQVLRQ
NJFP
D
E
JPDVV
E
D
E
D
E
(ORQJDWLRQ +\GUDXOLF
DWEUHDN %XUVW3UHVV
5HVLV.JFP
D
D
E
JPDVV
#&
3ODVWLFVWHHO
D
&RPSUHVVLYH )OH[XUDO
6WUHQJWK
6WUHQJWK
NJFP
.JFP
E
D
E
D
E
#&
1$
1$
$OXPLQLXPSXWW\
1$
1$
%UXVKDEOHFHUDPLF
1$
1$
1$
&HUDPLFSXWW\
1$
1$
1$
1$
1$
1$
1$
%URQ]HSXWW\
1$
1$
6WDLQOHVV6WHHOSXWW\
1$
1$
7LWDQLXPSXWW\
1$
1$
:HW6XUIDFH3XWW\
1$
1$
(SR[\6HDOHU
1$
1$
1$
1$
1$
1$
1$
1$
1$
1$
1$
1$
1$
PLQSXWW\
3XWW\
THEORITICAL COVERAGE AREAS IN SQ. FT. FOR VARIOUS COATING THICKNESS (in
mm.)
Coating
Dens. Coverage Dens. Coverage Dens. Coverage Dens. Coverage
Thickness
1 mm
1
10.2
1.6
6.34
1.8
5.7
2.0
5.1
2 mm
5.1
3.2
2.8
2.6
3 mm
3.4
2.2
1.9
1.7
4 mm
2.6
1.3
1.42
1.3
5 mm
2.04
1.3
1.13
1.02
6 mm
1.7
1.06
0.94
0.85
1 mm
2 mm
3 mm
4 mm
5 mm
6 mm
2.2
4.64
2.32
1.55
1.16
0.93
0.77
2.4
4.3
2.13
1.42
1.06
0.85
0.71
2.6
3.9
1.96
1.31
0.98
0.79
0.65
2.8
3.64
1.82
1.21
0.91
0.73
0.61
Please note: The above values are theoretical, the Actual Coverage shall be between 15 20%