Sei sulla pagina 1di 3

Appendix A

Data for the IEEE 24 bus Reliability Test System

The IEEE 24 bus Reliability Test System (or IEEE 24 bus RTS) [193], as shown in Fig.A.1,
is used in the thesis for different simulations conducted in Chapter 4, Chapter 5, Chapter 6
and Chapter 7. The bus data and transmission line data are given at 100 MVA in Table A.1
and Table A.2 respectively. The market data for reactive power offers (Bids) [57], as used in
Chapter 5 and Chapter 7, is given in Table A.3.

Fig.A.1: Single line diagram of the IEEE 24 bus Reliability Test System

Appendix A: Data for the IEEE 24 bus Reliability Test System

2013

Table A.1: Bus data for the IEEE 24 bus Reliability Test System (in p.u.)
Bus No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

PG,i
1.3796
1.3796
0.0000
0.0000
0.0000
0.0000
2.7231
0.0000
0.0000
0.0000
0.0000
0.0000
4.6406
0.0000
1.4069
1.4069
0.0000
3.6307
0.0000
0.0000
3.6307
2.7228
5.9907
0.0000

PD,i
1.0800
0.9700
1.8000
0.7400
0.7100
1.3600
1.2500
1.7100
1.7500
1.9500
0.0000
0.0000
2.6500
1.9400
3.1700
1.0000
0.0000
3.3300
1.8100
1.2800
0.0000
0.0000
0.0000
0.0000

QD,i
0.2200
0.2000
0.3700
0.1500
0.1400
0.2800
0.2500
0.3500
0.3600
0.4000
0.0000
0.0000
0.5400
0.3900
0.6400
0.2000
0.0000
0.6800
0.3700
0.2600
0.0000
0.0000
0.0000
0.0000

Vi
1.0350
1.0350
0.9913
0.9982
1.0186
1.0126
1.0250
0.9923
1.0022
1.0283
0.9892
1.0017
1.0200
0.9800
1.0140
1.0170
1.0392
1.0500
1.0231
1.0382
1.0500
1.0500
1.0500
0.9818

Vimax
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05

Vimin
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95

Base KV
138
138
138
138
138
138
138
138
138
138
230
230
230
230
230
230
230
230
230
230
230
230
230
230

Table A.2: Transmission line data for the IEEE 24 bus Reliability Test System (in p.u.)

Line No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

From
Bus No.
1
1
1
2
2
3
3
4
5
6
7
8
8
9
9
10
10
11
11
12
12
13
14

To
Bus No.
2
3
5
4
6
9
24
9
10
10
8
9
10
11
12
11
12
13
14
13
23
23
16

Bch (Full)

0.0026
0.0546
0.0218
0.0328
0.0497
0.0308
0.0023
0.0268
0.0228
0.0139
0.0159
0.0427
0.0427
0.0023
0.0023
0.0023
0.0023
0.0061
0.0054
0.0061
0.0124
0.0111
0.0050

0.0139
0.2112
0.0845
0.1267
0.1920
0.1190
0.0839
0.1037
0.0883
0.0605
0.0614
0.1651
0.1651
0.0839
0.0839
0.0839
0.0839
0.0476
0.0418
0.0476
0.0966
0.0865
0.0389

0.4611
0.0572
0.0229
0.0343
0.0520
0.0322
0.0000
0.0281
0.0239
2.4590
0.0166
0.0447
0.0447
0.0000
0.0000
0.0000
0.0000
0.0999
0.0879
0.0999
0.2030
0.1818
0.0818

Max. Line
Rating
1.7500
1.7500
1.7500
1.7500
1.7500
1.7500
4.0000
1.7500
1.7500
1.7500
1.7500
1.7500
1.7500
4.0000
4.0000
4.0000
4.0000
5.0000
5.0000
5.0000
5.0000
5.0000
5.0000
Table A.2 Contd

Dept. Of Electrical Engg., Faculty of Engineering, Dayalbagh Educational Institute, Agra-282110

300

Appendix A: Data for the IEEE 24 bus Reliability Test System

2013

Table A.2 Contd


24
25
26
27
28
29
30
31
32
33
34
35
36
37
38

15
15
15
15
16
16
17
17
18
18
19
19
20
20
21

16
21
21
24
17
19
18
22
21
21
20
20
23
23
22

0.0022
0.0063
0.0063
0.0067
0.0033
0.0030
0.0018
0.0135
0.0033
0.0033
0.0051
0.0051
0.0028
0.0028
0.0087

0.0173
0.0490
0.0490
0.0519
0.0259
0.0231
0.0144
0.1053
0.0259
0.0259
0.0396
0.0396
0.0216
0.0216
0.0678

0.0364
0.1030
0.1030
0.1091
0.0545
0.0485
0.0303
0.2212
0.0545
0.0545
0.0833
0.0833
0.0455
0.0455
0.1424

5.0000
5.0000
5.0000
5.0000
5.0000
5.0000
5.0000
5.0000
5.0000
5.0000
5.0000
5.0000
5.0000
5.0000
5.0000

Table A.3: Market data of reactive power offers (Bids) for the IEEE 24 bus Reliability Test System
Bus
No.

Unit
a0
No.
($)
1
0.96
2
0.94
1
3
0.85
4
0.83
1
0.50
2
0.42
2
3
0.69
4
0.65
1
0.75
7
2
0.80
3
0.70
1
0.68
13
2
0.70
3
0.75
1
0.94
14a
1
0.65
2
0.50
3
0.60
15
4
0.55
5
0.52
6
0.51
16
1
0.50
18
1
0.90
21
1
0.80
1
0.42
2
0.50
3
0.45
22
4
0.48
5
0.49
6
0.55
1
0.90
23
2
0.95
3
0.86
a
Synchronous condenser (SC)

m1
($/MVAr-h)
0.86
0.82
0.79
0.82
0.54
0.42
0.68
0.62
0.61
0.75
0.65
0.50
0.54
0.60
0.81
0.60
0.58
0.73
0.61
0.50
0.51
0.50
0.85
0.75
0.42
0.48
0.42
0.44
0.45
0.46
0.85
0.89
0.80

m2
($/MVAr-h)
0.86
0.82
0.79
0.82
0.54
0.42
0.68
0.62
0.61
0.75
0.65
0.50
0.54
0.60
0.81
0.60
0.58
0.73
0.61
0.50
0.51
0.50
0.85
0.75
0.42
0.48
0.42
0.44
0.45
0.46
0.85
0.89
0.80

m3
($/MVAr-h2)
0.46
0.45
0.39
0.40
0.28
0.35
0.39
0.37
0.43
0.36
0.32
0.31
0.39
0.50
0.00
0.30
0.25
0.38
0.27
0.26
0.27
0.30
0.48
0.41
0.17
0.20
0.38
0.35
0.33
0.32
0.48
0.55
0.45

QGmax
(MVAR)
10
10
30
30
10
10
30
30
60
60
60
80
80
80
200
6
6
6
6
6
80
80
200
200
16
16
16
16
16
16
80
80
150

Dept. Of Electrical Engg., Faculty of Engineering, Dayalbagh Educational Institute, Agra-282110

QGmin
(MVAR)
0
0
-25
-25
0
0
-25
-25
0
0
0
0
0
0
-50
0
0
0
0
0
-50
-50
-50
-50
-10
-10
-10
-10
-10
-10
-50
-50
-25

301

Potrebbero piacerti anche