Sei sulla pagina 1di 25

6/13/2014 ClockAssociated Parameters (TDM Mode)

http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 1/25
Clock Associated Parameters (TDM Mode)
Contents
1 Clock Associated Parameters (TDM Mode)
1.1 Clock Source Priority Sequence (1 Is the Highest)
1.2 Protection Status
1.3 AIS Alarm Generated
1.4 B1 BER Threshold-Crossing Generated
1.5 B2-EXC Alarm Generated
1.6 Higher Priority Clock Source Reversion Mode
1.7 Clock Source WTR Time(min)
1.8 Switching Status (Clock)
1.9 Lock Status
1.10 Clock Source ID
1.11 Synchronous Source
1.12 S1 Byte Synchronization Quality Information
1.13 NE Clock Working Mode
1.14 Clock Source Quality
1.15 S1 Byte Received
1.16 Line Port (Clock)
1.17 Control Status (Clock)
1.18 Line Port (Clock ID)
1.19 Enabled Status (Clock ID)
1.20 Data Output Method in Holdover Mode
1.21 Manual Setting of 0 Quality Level
1.22 Retiming Mode
1 Clock Associated Parameters (TDM Mode)
To synchronize the clocks on a network, you need to set the parameters that are associated with clocks.
Clock Source Priority Sequence (1 Is the Highest)
Protection Status
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 2/25
AIS Alarm Generated
B1 BER Threshold-Crossing Generated
B2-EXC Alarm Generated
Higher Priority Clock Source Reversion Mode
Clock Source WTR Time(min)
Switching Status (Clock)
Lock Status
Clock Source ID
Synchronous Source
S1 Byte Synchronization Quality Information
NE Clock Working Mode
Clock Source Quality
S1 Byte Received
Line Port (Clock)
Control Status (Clock)
Line Port (Clock ID)
Enabled Status (Clock ID)
Data Output Method in Holdover Mode
Manual Setting of 0 Quality Level
Retiming Mode
Parent topic: List of Parameters
1.1 Clock Source Priority Sequence (1 Is the Highest)
Description
The Clock source priority sequence(1 is the highest) parameter specifies the priority level of a certain clock source in the system clock priority table.
Impact on the System
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 3/25
When the SSM protocol is disabled or the extended SSM protocol is enabled, the current trace clock source may be changed if the clock source
priority sequence is changed. As a result, bit errors may occur in the service or the service may be interrupted transiently.
Values
Value Range Default Value
1, 2, 3... 1
The following table lists the description of each value.
Value Description
1 Indicates that this clock source is at the highest priority level in the system clock priority table.
2 Indicates that this clock source is at the second highest priority level in the system clock priority
table.
3 Indicates that this clock source is at the third highest priority level in the system clock priority table.
... ...
Configuration Guidelines
This parameter specifies the priority level of a certain clock source in the system clock priority table. The value ranges from 1 to N. N represents the
total number of clock sources in the system clock priority table. Generally, the internal clock source is at the lowest priority level.
For example, there are four clock sources in the system clock priority table: one external clock source, one line clock source, one tributary clock
source, and one internal clock source. The priority level of the external clock source is set to 1, the priority level of the line clock source is set to 2, the
priority level of the tributary clock source is set to 3 (the priority levels of the external clock source, line clock source, and tributary clock source cannot
be the same), and the priority level of the internal clock source is always set to 4.
In the actual application, this parameter is set according to the specific networking situation.
Parent topic: Clock Associated Parameters (TDM Mode)
1.2 Protection Status
Description
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 4/25
The Protection Status parameter indicates the working mode of the clock protocol for a clock subnet.
Impact on the System
The algorithm adopted by the system to select a clock source varies with the parameter value.
Values
Value Range Default Value
Start Extended SSM Protocol, Start Standard SSM Protocol, Stop SSM Protocol Stop SSM Protocol
Configuration Guidelines
The protection status of the entire clock subnet should be consistent. To avoid a clock tracing loop on a ring or mesh network, it is recommended that
you set this parameter to Start Extended SSM Protocol.
Relationship with Other Parameters
None.
Related Information
As a mechanism adopted by the synchronous network for synchronization management, the standard SSM protocol is loaded in the lower four bits of
the S1 byte. The standard SSM protocol allows nodes to exchange the quality information of clock sources. Hence, the SSM protocol enables the
system to automatically select the clock source with the highest priority and also avoids a clock inter-lock. The standard SSM protocol is applicable to
interconnection with the equipment of other suppliers.
Based on the standard SSM protocol, the extended SSM protocol presents a concept of clock source ID. The higher four bits of the S1 byte indicate a
unique clock source ID, which is transmitted with the SSM. When receiving the S1 byte, a node checks the clock source ID to see whether the clock
source derives from itself. If the clock source derives from the node, the node considers the clock source as unavailable. In this manner, a clock inter-
lock loop is avoided when the clock tracing path is configured as a ring. The extended SSM protocol is applicable to the interconnection of transmission
equipment from Huawei.
When the SSM protocol is disabled, the clock source is selected according to the priority table.
Parent topic: Clock Associated Parameters (TDM Mode)
1.3 AIS Alarm Generated
Description
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 5/25
The AIS Alarm Generated parameter is used to specify whether an AIS alarm is a condition for triggering the switching of clock sources.
Impact on the System
The system running is not affected.
Values
Value Range Default Value
Yes, No No
The following table lists the description of each value.
Value Description
Yes Indicates that an AIS alarm is the sufficient condition to trigger clock source switching.
No Indicates that an AIS alarm is not a condition for triggering clock source switching.
Configuration Guidelines
It is recommended to set the AIS alarm as the condition for triggering clock source switching in actual application to ensure system performance.
Relationship with Other Parameters
None.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.4 B1 BER Threshold-Crossing Generated
Description
The B1 BER Threshold-Crossing Generated parameter is used to specify whether a B1 BER threshold-crossing alarm is a condition for triggering
clock source switching. B1 BER Threshold-Crossing alarm is an index for measuring the performance of clock source signals.
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 6/25
Impact on the System
The system running is not affected.
Values
Value Range Default Value
Yes, No No
The following table lists the description of each value.
Value Description
Yes Indicates that a B1 BER threshold-crossing alarm is the sufficient condition for triggering clock source switching.
No Indicates that a B1 BER threshold-crossing alarm is not the condition for triggering clock source switching.
Configuration Guidelines
A B1 BER threshold-crossing alarm indicates that the transmitted signal and the clock in the signal are being interfered. Therefore, this parameter can
be set as a condition for triggering clock source switching in actual application to ensure system performance.
Relationship with Other Parameters
None.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.5 B2-EXC Alarm Generated
Description
The B2-EXC Alarm Generated parameter is used to specify whether a B2-EXC alarm is a condition for triggering clock source switching. B2-EXC alarm
is an index for measuring the performance of clock source signals.
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 7/25
Impact on the System
The system running is not affected.
Values
Value Range Default Value
Yes, No No
The following table lists the description of each value.
Value Description
Yes Indicates that a B2-EXC alarm is the sufficient condition for triggering clock source switching.
No Indicates that a B2-EXC alarm is not the condition for triggering clock source switching.
Configuration Guidelines
A B2-EXC alarm indicates that the transmitted signal and the clock in the signal are being interfered. Therefore, this parameter can be set as a condition
for triggering clock source switching in actual application to ensure system performance.
Relationship with Other Parameters
None.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.6 Higher Priority Clock Source Reversion Mode
Description
The Higher Priority Clock Source Reversion Mode parameter specifies whether to switch from the lower-priority clock source back to the higher-
priority clock source after the higher-priority clock source is restored to normal.
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 8/25
Impact on the System
If the conditions for clock source switching are excessively strict, jitters may occur in the monitoring results of the clock status. If the auto-revertive
mode is selected, the frequent switching of clock sources may affect the service.
Values
Value Range Default Value
Non-Revertive, Auto-Revertive Auto-Revertive
The following table lists the description of each value.
Value Description
Non-Revertive Indicates that the higher-priority clock source cannot be selected automatically after it is restored to normal.
Auto-Revertive Indicates that the higher-priority clock source is selected automatically after it is restored to normal.
Configuration Guidelines
If the conditions for clock source switching are properly set and the switching of clock sources can be guaranteed, the Auto-Revertive mode can be
selected to improve clock quality. Otherwise, the Non-Revertive mode is recommended to avoid clock jitters.
Relationship with Other Parameters
None.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.7 Clock Source WTR Time(min)
Description
The Clock Source WTR Time(min) parameter is used to specify the wait-to-restore (WTR) time when the Higher Priority Clock Source Reversion
Mode parameter is set to Auto-Revertive. When a clock source is restored to its valid status, the system does not regard it as a valid source
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 9/25
immediately but verifies the validity of the clock source in a specific period of time. The system regards the clock source as a valid source only if the
clock source remains valid during the specific period of time. This specific period of time is called the WTR time of the clock source.
Impact on the System
Insufficient WTR time may result in wrong judgments on clock source restoration and clock status jitters, which may interrupt the service.
Values
Value Range Default Value
0-12 5
Configuration Guidelines
The WRT time is counted in minutes. The shorter the WTR time is, the faster the clock is recovered, and the higher the average clock quality is. On the
other hand, the shorter the WTR time is, the more likely the clock jitters are caused due to unstable clock signals. Therefore, do not set the WTR time
to 0 in actual application.
Relationship with Other Parameters
The setting of the WTR time is valid only when the Higher Priority Clock Source Reversion Mode parameter is set to Auto-Revertive.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.8 Switching Status (Clock)
Description
The Switching Status (Clock) parameter indicates the current switching status of a clock source in the clock priority table.
Impact on the System
The system running is not affected.
Values
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 10/25
Value Range Default Value
Normal, Forced Switching, Manual Switching Normal
The following table lists the description of each value.
Value Description
Normal Indicates that the clock source in the clock priority table is in the normal trace status.
Forced Switching Indicates that the clock source in the clock priority table is in the forced switching status.
Manual Switching Indicates that the clock source in the clock priority table is in the manual switching status.
Configuration Guidelines
None.
Relationship with Other Parameters
None.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.9 Lock Status
Description
The Lock Status parameter indicates the lock status of a clock source in the priority table.
Impact on the System
The system running is not affected.
Values
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 11/25
Value Range Default Value
Lock, Unlock Unlock
The following table lists the description of each value.
Value Description
Lock Indicates that a certain channel of clock source in the priority table is in the lock status where the switching of clock sources is not allowed.
Unlock Indicates that a certain channel of clock source in the priority table is in the unlock status where the switching of clock sources is allowed.
Configuration Guidelines
None.
Relationship with Other Parameters
None.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.10 Clock Source ID
Description
The Clock Source ID parameter specifies the clock source ID information that is transmitted in the four most significant bits of the overhead S1 byte to
avoid timing loops. This parameter works in the extended SSM protocol mode.
Impact on the System
The system running is not affected.
Values
Value Range Default Value
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 12/25
1-15, None None
Configuration Guidelines
In actual application where the extended SSM protocol is enabled, the clock source IDs should be set as required by network planning to ensure that
the ID is networkwide unique.
Relationship with Other Parameters
This parameter is valid only when the extended SSM protocol is enabled.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.11 Synchronous Source
Description
The Synchronous Source parameter indicates the synchronous clock source that is being traced. The synchronous clock source here refers to a
certain clock source contained in the system clock priority table.
Impact on the System
The system running is not affected.
Values
Value Range Default Value
Clock Source in System Clock Priority Table None
The following table lists the description of each value.
Value Description
Clock Source in System Clock
Priority Table
Indicates that the system clock priority table contains the tributary clock sources, line clock sources, external
clock sources, and internal clock sources.
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 13/25
Configuration Guidelines
The OptiX OSN 550 does not support External Clock Source.
Relationship with Other Parameters
None.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.12 S1 Byte Synchronization Quality Information
Description
The S1 Byte Synchronization Quality Information parameter indicates the synchronization quality information in the S1 byte that is output by the
current traced synchronous source. The S1 byte defined by the ITUT is used to transmit the quality information about the clock sources. It indicates the
quality information of 16 types of synchronous sources with bits 5-8 of the S1 byte in the section overhead. With this quality information and certain
switching protocols, the automatic protection switching of the synchronization clock can be realized in the synchronous network.
Impact on the System
The system running is not affected.
Values
Value Range Default
Value
Synchronous Source Unavailable, Quality Unknown, G.811 Reference Clock, G.812 Transit Clock, G.812 Local Clock, SDH equipment
timing source (SETS) signal
-
The following table lists the description of each value.
Value Description
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 14/25
Synchronous Source
Unavailable
Indicates that the SSM protocol is disabled and the S1 byte synchronization quality information output by the
synchronous source is not available.
Quality Unknown Indicates that the SSM protocol is started but the S1 byte synchronization quality information output by the synchronous
source is unknown.
G.811 Reference Clock Indicates that the SSM protocol is started and the S1 byte synchronization quality information output by the
synchronous source is the G.811 reference clock.
G.812 Transit Clock Indicates that the SSM protocol is started and the S1 byte synchronization quality information output by the
synchronous source is the G.812 transit clock.
G.812 Local Clock Indicates that the SSM protocol is started and the S1 byte synchronization quality information output by the
synchronous source is the G.812 local clock.
SDH equipment timing
source (SETS) signal
Indicates that the SSM protocol is enabled and the S1 byte synchronization quality information output by the
synchronous source is the synchronous equipment timing source (SETS) clock.
Configuration Guidelines
None.
Relationship with Other Parameters
None.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.13 NE Clock Working Mode
Description
The NE Clock Working Mode parameter is used to set the current working mode of the system clock to the normal, holdover or free-run mode.
Impact on the System
The system running is not affected.
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 15/25
Values
Value Range Default Value
Normal Mode, Holdover Mode, Free-Run Mode -
The following table lists the description of each value.
Value Description
Normal
Mode
Indicates that the NE clock works in the tracing mode. That is, the NE clock traces and locks the working mode of its upper-level clock.
Holdover
Mode
Indicates that the NE clock works in the holdover mode. That is, in this mode, the NE clock uses the frequency information that is stored
before all timing reference signals are lost as its timing reference.
Free-Run
Mode
Indicates that the NE clock works in the free-run mode. That is, the internal oscillator works in this mode when all external timing reference
signals are lost.
Configuration Guidelines
None.
Relationship with Other Parameters
None.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.14 Clock Source Quality
Description
The Clock Source Quality parameter specifies the clock source quality information. Such information is extracted from the S1 byte of individual clock
sources according to the SSM encoding rules after the SSM protocol is enabled. If the clock quality information cannot be extracted, this parameter
needs to be set manually.
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 16/25
Impact on the System
The system running is not affected.
Values
Value Range Default Value
Automatic Extraction, G.811 Clock Signal, G.812 Transit Clock Signal, G.812 Local Clock Signal, G.813 SDH Equipment Timing
source (SETS) Signal, Unknown Synchronization Quality
Automatic
Extraction
The following table lists the description of each value.
Value Description
Automatic Extraction Indicates that the clock quality information is extracted automatically according to the encoding rules
compliant with the SSM protocol.
G.811 Clock Signal Indicates that the clock source quality is manually set to the G.811 clock signal.
G.812 Transit Clock Signal Indicates that the clock source quality is manually set to the G.812 transit clock signal.
G.812 Local Clock Signal Indicates that the clock source quality is manually set to the G.812 local clock signal.
G.813 SDH Equipment Timing source
(SETS) Signal
Indicates that the clock source quality is manually set to the SETS clock signal.
Unknown Synchronization Quality Indicates a message that is set in the negative direction of the selected synchronization source to avoid direct
mutual locking of two adjacent NEs.
Configuration Guidelines
This parameter is usually set to Automatic Extraction. When the equipment is interconnected to an NE from another manufacturer that complies with
a different protocol, the clock source quality can be specified manually.
Relationship with Other Parameters
The clock quality information is valid only when the SSM protocol is enabled.
Related Information
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 17/25
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.15 S1 Byte Received
Description
The S1 Byte Received parameter indicates the value of the S1 byte of the current traced source in the system clock priority table.
Impact on the System
The system running is not affected.
Values
Value Range Default Value
SDH equipment timing source (SETS) signal, G.812 Local Clock, G.812 Transit Clock, G.811 Reference Clock,
Synchronous Source Unavailable
Synchronous Source
Unavailable
The following table lists the description of each value.
Value Description
SDH equipment timing source (SETS) signal Indicates that the clock quality of the current traced source is 0x0b.
G.812 Local Clock Indicates that the clock quality of the current traced source is 0x08.
G.812 Transit Clock Indicates that the clock quality of the current traced source is 0x04.
G.811 Reference Clock Indicates that the clock quality of the current traced source is 0x02.
Synchronous Source Unavailable Indicates that the clock quality of the current traced source is 0x0f.
Configuration Guidelines
None.
Relationship with Other Parameters
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 18/25
None.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.16 Line Port (Clock)
Description
The Line Port (Clock) parameter is used to specify the output port of SSM quality information about the line clock source and external clock source
available in the existing system. This output port can transmit the quality information about the clock source by sending the S1 byte to the downstream
NE.
Impact on the System
The system running is not affected.
Values
Value Range Default Value
Line Clock Source Port, External Clock Source Port -
The following table lists the description of each value.
Value Description
Line Clock
Source Port
Indicates that only the port on the line board where both physical board and logical board have been configured properly can be
used as the output port of SSM quality information.
External Clock
Source Port
Indicates that only the port on the board with external clock interfaces where both physical board and logical board have been
configured properly can be used as the output port of SSM quality information.
Configuration Guidelines
None.
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 19/25
Relationship with Other Parameters
None.
Related Information
The standard SSM protocol mode, also called as QL_ENABLE mode in the Recommendation G.781, is a universal switching mode of clock source. In
this standard SSM protocol mode, when a clock source becomes invalid, the system automatically traces the clock source of the highest quality in the
clock priority table according to the quality information contained in the SSM protocol. If two clock sources are both of the highest quality, the clock
source of a higher priority is selected.
Parent topic: Clock Associated Parameters (TDM Mode)
1.17 Control Status (Clock)
Description
The Control Status (Clock) parameter is used to specify whether the line port can transmit the quality information about the clock source by sending
the S1 byte to the downstream NE. By setting this parameter, the transmission of the S1 byte through the ports of the clock source can be enabled or
disabled.
Impact on the System
Modifying the Control Status (Clock) parameter may cause loss of clock quality information transmitted to the downstream NE. Therefore, the clock of
the downstream NE may be asynchronous with the clocks of other NEs in the synchronous network.
Values
Value Range Default Value
Enable, Disabled Enable
The following table lists the description of each value.
Value Description
Enable Indicates that the transmission of the S1 byte through the corresponding line port is enabled.
Disabled Indicates that the transmission of the S1 byte through the corresponding line port is disabled.
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 20/25
Configuration Guidelines
The Control Status (Clock) parameter can be set to an enabled or disabled status as required. The status is enabled by default. In actual application, if
the output clock source on the line board is valid, the transmission of the S1 byte through line port is allowed so that the clocks of the NEs in the entire
synchronous network are synchronous.
Relationship with Other Parameters
None.
Related Information
The standard SSM protocol mode, also called QL_ENABLE mode in the G.781, is a universal switching mode of the clock source. In this standard SSM
protocol mode, when a clock source becomes invalid, the system automatically traces the clock source of the highest quality in the clock priority table
according to the quality information contained in the SSM protocol. If two clock sources are both of the highest quality, the clock source of a higher
priority is selected.
Parent topic: Clock Associated Parameters (TDM Mode)
1.18 Line Port (Clock ID)
Description
The Line Port (Clock ID) parameter is used to set clock source ID in the S1 byte for the interconnection and isolation between different clock subnets.
In the extended SSM protocol mode, the four most significant bits of the S1 byte are used for identifying the clock source ID to improve the clock
protection performance in the SDH network and to effectively avoid the timing loop. The clock source ID is output by the line port only. The external
clock cannot output the clock source ID.
Impact on the System
The system running is not affected.
Values
Value Range Default Value
Line Clock Source Port -
The following table lists the description of each value.
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 21/25
Value Description
Line Clock
Source Port
Indicates that only the port on the line board where both physical board and logical board have been configured properly can be
used as the output port of the clock source ID.
Configuration Guidelines
None.
Relationship with Other Parameters
None.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.19 Enabled Status (Clock ID)
Description
Then Enabled Status (Clock ID) parameter is used to enable or disable the output of the clock source ID for the interconnection and isolation between
different subnets. In the extended SSM protocol mode, the four most significant bits of the S1 byte are used for identifying the clock source ID to
improve the clock protection performance in the SDH network and to effectively avoid the timing loop. This parameter is used to enable or disable the
output of the clock source ID. The output of the clock source ID by internal clock source cannot be disabled. This parameter cannot be set for external
clock, because the external clock cannot output the clock source ID.
Impact on the System
In a system where the extended SSM protocol is adopted, modifying the Enable Status (Clock ID) parameter may result in clock tracing loop, which
may make the originally synchronous clock sources asynchronous.
Values
Value Range Default Value
Enabled, Disabled Enabled
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 22/25
The following table lists the description of each value.
Value Description
Enabled Indicates that the output of clock source ID through corresponding line ports is allowed.
Disabled. Indicates that the output of clock source ID through corresponding line ports is forbidden.
Configuration Guidelines
The Enabled Status (Clock ID) parameter can be set to an enable of disabled status as required. The status is enabled by default. In actual
application, as long as the extended SSM protocol is started and the output clock source on the line board is valid, it is allowed to output clock source
ID in the four most-significant bits of the S1 byte through line ports. This can ensure clock synchronization among the NEs in the entire synchronous
network and prevent the occurrence of timing loops.
Relationship with Other Parameters
There are three working modes of the SSM protocol: the disabled, standard and extended SSM protocol modes. This parameter is valid only when the
extended SSM protocol mode is adopted by the current clock of the NEs.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.20 Data Output Method in Holdover Mode
Description
The Data Output Method in Holdover Mode parameter is used to specify whether the data is output normally or the latest data is kept when the NE
clock is in the holdover mode.
Impact on the System
The system running is not affected.
Values
Value Range Default Value
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 23/25
Normal Data Output Mode, Keep the Latest Data Normal Data Output Mode
The following table lists the description of each value.
Value Description
Normal Data
Output Mode
Indicates the normal data output mode. The duration of this output mode is determined by the phase lock. This data output mode
can continue for a maximum of 24 hours.
Keep the Latest
Data
Indicates that the latest phase-locked data is kept. This data output mode is a forced holdover mode.
Configuration Guidelines
The Keep the Latest Data mode is a forced holdover mode. Therefore, the clock accuracy is not high. In actual application, the Normal Data Output
mode is recommended.
Relationship with Other Parameters
The NE clock can work in three modes: the trace, holdover, and free-run modes. This parameter is valid only when the NE clock is working in the
holdover mode.
Related Information
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.21 Manual Setting of 0 Quality Level
Description
The Manual Setting of 0 Quality Level parameter is used to specify the 0 quality level that is not provided in the SSM protocol. Users can add this
parsing rule to specify the quality level represented by 0.
Impact on the System
The system running is not affected.
Values
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 24/25
Value Range Default Value
Do Not Use For Synchronization, G.811 Reference Clock, G.812 Transit Clock, G.812 Local Clock, SETS Clock, Between G.811
Reference Clock and G.812 Transit Clock, Between G.812 Transit Clock and G.812 Local Clock, Between G.812 Local Clock and
synchronous equipment timing source (SETS)
Do Not Use For
Synchronization
The following table lists the description of each value.
Value Description
Do Not Use For Synchronization Indicates a message that is set in the negative direction of the selected synchronization source to avoid
direct mutual locking of two adjacent NEs.
G.811 Reference Clock Indicates that the clock signal complies with the G.811 protocol.
G.812 Transit Clock Indicates that the transit exchange clock signal complies with the G.812 protocol.
G.812 Local Clock Indicates that the local office signal complies with the G.812 protocol.
SETS Clock Indicates the synchronous equipment timing source (SETS).
Between G.811 Reference Clock and
G.812 Transit Clock
Indicates that the specified quality level is inferior to the quality level of the G.811 reference clock signal
but is superior to the quality level of the G.812 transit clock signal.
Between G.812 Transit Clock and G.812
Local Clock
Indicates that the specified quality level is inferior to the quality level of the G.812 transit clock signal but is
superior to the quality level of the G.812 local clock signal.
Between G.812 Local Clock and
synchronous equipment timing source
(SETS)
Indicates that the specified quality level is inferior to the quality level of the G.812 local clock signal but is
superior to the quality level of the synchronous equipment timing source (SETS) clock signal.
Configuration Guidelines
In actual application, this parameter can be set according to the quality information about specific NE clocks.
Relationship with Other Parameters
The setting of this parameter is valid only when the SSM protocol is enabled.
Related Information
6/13/2014 ClockAssociated Parameters (TDM Mode)
http://localhost:7890/printtopics.html?time=Fri%20Jun%2013%202014%2012:39:43%20GMT+0530%20(Sri%20Lanka%20Standard%20Time) 25/25
None.
Parent topic: Clock Associated Parameters (TDM Mode)
1.22 Retiming Mode
Description
The Retiming Mode parameter specifies whether the retiming clock, tributary clock, or cross-connect (external) clock is used.
Impact on the System
If the downstream board that corresponds to this board provides the clock source for the downstream NE, the selection of the user affects the precision
of the downstream NE.
Values
Value Range Default Value
Normal, Retiming Mode of Tributary Clock, Retiming Mode of Cross-Connect Clock Normal
The following table provides the description of each value.
Value Description
Normal Indicates that the retiming clock is not used.
Retiming Mode of Tributary Clock Indicates that the tributary clock is used as the retiming clock.
Retiming Mode of Cross-Connect Clock Indicates that the cross-connect (external) clock is used as the retiming clock.
Configuration Guidelines
Select the proper clock according to the actual networking planning of the user.
Parent topic: Clock Associated Parameters (TDM Mode)