Sei sulla pagina 1di 5

Steam Turbine Control System

Description Diagram Legend




Power Plant iden- Title Coor-
tification System dinete




LBC10 AA001 Swing Check Valve of CRH E7
KA01 Rotary Servomotor E7
LBC10 CG001 B Limit Switch, Open Position E7
C Limit Switch, Closed Position E7
D Limit Switch, Open Position E7
E Limit Switch, Closed Position E7

LBS21 AA001 Extraction Check Valve A2 E12,13
KA01 Servomotor E12,13
LBS21 CG001A Remote Position Indicator E12,13

LBS31 AA001 Extraction Check Valve A3 E13
KA01 Servomotor E13
LBS31 CG001A Remote Position Indicator E13

LBS31 AA002 Extraction Check Valve A3 E13
LBS31 CG002 A Remote Position indicator E13

LBS41 AA001 Extraction Check Valve A4 C10
KA01 Servomotor C10
LBS41 CG00 1A Remote Position Indicator C10

LBS41 AA002 Extraction Check Valve A4 C10
KA01 Servomotor C10
LBS41 CG002A Remote Position Indicator C10

LBS42 AA001 Extraction Check Valve A4 AB11
KA01 Servomotor A 11
LBS42 CG001A Remote Position Indicator B 11

LBS42 AA002 Extraction Check Valve A4 AB1 1,12
KA01 Servomotor A12
LBS41 CG002A Remote Position Indicator B12

LBQ50AA001 Extraction Check Valve A5 E9
KA01 Servomotor E9
LBQ50CG001 A Remote Position Indicator E9

LBQ5OAA002 Extraction Check Valve A5 E9
LBQ50 CG002A Remote Position Indicator E9

MAA10 + 20
AA001 Main Stop Valve ABC7
KA01 Piston AB7
KA02 Piston Disc B7

MAA10 + 20
CG001 B,F,H Limit Switch, Open Valve Position B7
C,G,J Limit Switch, Closed Valve Position B7
D Limit Switch, Open Valve PositionATT B7
E Limit Switch, Closed Valve PositionATTB7

MAA10+ 20
AA002 Main Control Valve BC7,8
KA01 Servomotor C7,8
KA02 Piston C7
KA05 Pre Control Pilot Valve C7





Power Plant iden- Title Coor-
tification System dinete

KA06 Relay Piston for Pre Control Pilot ValveC7
KA07 Main Pilot Valve C7
KA09 Hand wheel for Testing Device B7
M Electrical Motor for Testing Device B7
AA002 MS61 Torque limit Switch,
Testing Device 100% ATT B7
MS62 Travel Limit Switch,
Testing Device 100% ATT B7
MS72 Torque Limit Switch,
Testing Device 0% A TT B7
MS73 Travel Limit Switch, B7
Testing Device 0% ATT

MAA10 + 20
CG002 A Remote Position Indicator C7
C Limit Switch, Closed Valve Position ATT C7

MAB10 +20
AA001 Reheat Stop Valve ABC9
KA01 Piston A9
KA02 Piston Disc A9

MAB10 + 20
CG001 B,F,H, Limit Switch, Open Valve Position A9
C,G,J Limit Switch, Closed Valve Position A9
D Limit Switch, Open Valve Position ATT A9
E Unlit Switch,Closed Valve Position ATT A9


MAB10+ 20 Main Control Valve BC9,10
AA002

KA01 Servomotor C10
KA02 Piston C10
KA05 Pre Control Pilot Valve C10
KA06 Relay Piston for Precontrol Pilot ValveC10
KA07 Main Pilot Valve C10
KA09 Hand wheel for Testing Device B10
M Electrical Motor for Testing Device B10
MS61 Torque Limit Switch,
Testing Device 100% ATT B10
MS62 Travel Limit Switch,
Testing Device 100% ATT B10
MS72 Torque Limit Switch,
Testing Device 0% ATT B10
MS73 Travel Limit Switch, B10
Testing Device 0% ATT

MAB10 + 20
CG002 A Remote Position Indicator C10
C Limit Switch, Closed Valve Position C10
ATT
MAD12
CY011,012,013 Electrical Thrust Bearing Trip D8

MAG01 AA011 Low Vacuum Trip. B5
MAG01CG01 B Limit Switch, Not Reset B5
C Limit Switch, Alarm B5
E Limit Switch, Alarm ATT B5
MAG01AA016 Condenser Safety Device
(Bypass Control) G 9
BHEL Haridwar 5.1-0681-02/1

Power Plant iden- Title Coor-
tification System dinete


MAV21 AP001 Main Oil Pump E1

MAV21BT001 Oil Filter
(Hydraulic Control Equipment Rack) D4

MAX31
BB011, 016 Accumulator for HP Servomotor,
Main Control Valves B7

MAX31 Accumulator for HP Servomotor,
BB21, 26 Reheat Control Valves B9

MAX31 BB021 Accumulator for HP Servomotor,
BB041,049 Bypass Control Valves C11

MAX32
BT011 +012 Fluid Filter for Pre Control.
Main Control Valves A7





















































Power Plant iden- Title Coor-
tification System dinete

MAX32BT021 Fluid Filter for Pre Control,
Reheat Control Valves A10

MAX32BT081 Fluid Filter for Pre Control,
Bypass Control Valves C11

MAX41 CP50l Pressure Gauge. Control Fluid
(Hydraulic Control Equipment Rack) C2

MAX42AA001 Slide Valve for Swing Check Valve
Cold Reheat D7

MAX42AA002 Slide Valve for Swing Check Valve
Cold Reheat D8

MAX42AA011 Non-Return Valve B1

MAX42BT001 Fluid Filter
(Hydraulic Control Equipment Rack) C1

MAX42BT002 Fluid Filter
(Hydraulic Control Equipment Rack) C2

MAX42BT003 Fluid Filter
(Hydraulic Control Equipment Rack) B4

MAX42BT021 Fluid Filter (Hydraulic
Bypass Control Equipment Rack) G6

MAX42BT022 Fluid Filter for Water Injection Valves
(Hydraulic Bypass Control
Equipment Rack) A12

MAX42CP501 Pressure Gauge, Control Fluid
(Hydraulic Bypass Control
Equipment Rack) F6

MAX42CP511 Pressure Gauge, Control Fluid Water
Injection Valve Open B12

MAX42CP512 Pressure Gauge. Control Fluid Water
Injection Valve for Sequential Water
Injection Open B13

MAX44AP001 Hydraulic Speed Transmitter E1

MAX44CP501 Pressure Gauge, Primary Oil A5

MAX45BB001 Accumulator for Extraction Valve
Relay E4

MAX45BY001 Electro-Hydraulic Converter F4
KA01 Follow-Up Piston for Main
Control Valves F5
KA02 Follow Up Piston for Reheat
Control Valv8S F5
KA04 Sleeve F4
KA05 Piston F4
KA06 Helical Spring F4
KA08 Piston F4
KA10 Adjusting Device Control Valves F5
KA11 Manual Adjusting Device F5
5.1-0681-02/2

Power Plant iden- Title Coor-
tification System dinete

MAX45
CG001 A Remote Position Indicator F4
K Remote Position Indicator F4
T Solenoid F4
B Limit Switch Operating Without Bypass
Valves and Adjusting Device Blocked F5
C Limit Switch, Displacement of
Control Valves F5

MAX45BY011 Hydraulic Converter F2
KA01 Follow-up Piston for Main Control Valves F3
KA02 Follow-Up Piston for Reheat Control F3
valve
KA04 Sleeve G3
KA05 Piston G3
KA06 Helical Spring F3
KA07 Pilot Valve G2
KA08 Piston G3
KA09 Proportional Band Adjustment G2
KA10 Adjusting Device Control Valves F4
KA11 Manual Adjusting Device F4
MAX45CG011 B Limit Switch, Operation without Bypass
Valves and Adjusting Device Blocked F3
C Limit Switch, Displacement of control
valves F4

MAX45CP501 Pressure Gauge Secondary Fluid
Main Control valves F2

MAX45CP511 Pressure Gauge, Secondary Fluid
Reheat Control Valves E2

MAX46BY001 Hydraulic Speed Governor G1
KA01 Hand wheel F2
KA02 Speed Setting Spring F1
KA03 Link F1
KA04 Sleeve F2
KA05 Piston F2
KA06 Helical Spring F2
KA07 Overspeed Tester Lever F2
KA08 Auxiliary Follow-up Piston F2
KA09 Governor Bellows G1
M Electrical Motor F1

MAX46CG001 A Remote Position Indicator F2
B Limit Switch 100%
(Start-Up Automatic) F2

MAX46CP501 Pressure Gauge.
Auxiliary Secondary Fluid F2

MAX47
AA011 +012 Test Valve for Main Stop Valves B6

MAX47
AA021 +022 Test Valve for Reheat Stop Valves A9

MAX47BY001 Starting and Load Limit Device F1
KA01 Hand wheel F1
KA02 Valve F1
M Electrical Motor F1

MAX47CG001 A Remote Position Indicator F1
B Limit Switch, 100% G1
C Limit Switch, 0% G1
D Limit Switch, 42% G1






Power Plant iden- Title Coor-
tification System dinete

MAX47CG001F Limit Switch, 56% G1
MAX47CP501 Pressure Gauge, Start-up Fluid G1
MAX48 CP501 Pressure Gauge,
Auxiliary start-up fluid E3


MAX51
AA005 +006 Main Trip Valve B2

MAX 51
CG005+006 C Limit Switch, Alarm B2
E Limit Switch, Alarm, ATT B2

MAX51 AA011 Extraction Valve Relay D5
KA01 Valve D5
KA02 Valve D5

MAX51AA041 Slide Valve for Extraction
Check Valve A2 E12

MAX51 AA044 Slide Valve for Extraction
Check Valve A3 E13
MAX51 AA047 Slide Valve for Extraction
Check Valve A4 C12

MAX51 AA048 Slide Valve for Extraction
Check Valve A4 A 11

MAX 51 AA 050 Slide Valve for Extraction
Check Valve A4 C12

MAX 51 AA051 Slide Valve for Extraction
Check Valve A4 A11

MAX 51 AA056 Slide Valve for Extraction
Check Valve A5 E9

MAX51AA211 Changeover Valve B3

MAX51 CG211B Limit Switch, up Normal Position ATT B3
C Limit Switch, Down- Test Position ATT B3

MAX51CP501 Pressure Gauge, Trip Fluid A3

MAX51 CP522 Pressure Gauge, Trip Fluid above piston
527 Main Stop Valve A6

MAX 51 CP523 Pressure Gauge, Trip Fluid below piston
528 Disc Main Stop Valve B6

MAX51 CP542 Pressure Gauge, Trip Fluid above Piston
547 Reheat Stop Valve A9

MAX51 CP543 Pressure Gauge, Trip Fluid below Piston
548 Disc Reheat Stop valve B9

MAX52AA005 Local/Manual Trip Valve B2
MAX52 CG005 C Limit Switch, Alarm B2
E Limit Switch, Alarm ATT B2

MAX 52 CP501 Pressure Gauge, Aux, Trip Fluid D3

5.1-0681-02/3

Power Plant Iden- Title Coor- Power Plant Iden- Title Coor-
tification System dinate tification System dinate

MYA01
CS011-013 Electrical Speed Transmitter E1
MAG01 AA201 Solenoid Valve for Testing
Low Vacuum Trip B4
MAX42AA001 Solenoid Valve, Adjustment of
Control Valves F5

MAX45AA001 Solenoid Valve for Load Shedding Relay
in Secondary Fluid to Reheat
Control Valves E5

MAX46AA011 Solenoid Valve for Load Shedding Relay
in Auxiliary Secondary Fluid G2

MAX47
AA211 +212 Solenoid Valve for start -up Fluid,
Main Stop Valve B5
MAX 47
AA221 +222 Solenoid Valve for Start-up Fluid,
Reheat Stop Valves B8

MAX48
AA201 +202 Solenoid Valve for Auxiliary
Start-Up Fluid B1,2

MAX51AA021 Solenoid Valve for Extraction
Check Valve E12

MAX51AA024 Solenoid Valve for Extraction
Check Valve E13

MAX51AA027 Solenoid Valve for Extraction
Check Valve A4.1 C 12

MAX51 AA028 Solenoid Valve for Extraction
Check Valve A4.2 A10

MAX51 AA030 Solenoid Valve for Extraction
Check Valve A4.1 C12

MAX51AA031 Solenoid Valve For Extraction
MAX61 Check Valve A4.2 A11
AA011 +012 Test Valve for Main Stop Valves B6
MAX51 AA036 Solenoid Valve for Extraction
MAX61 Check Valve A5 E9
AA021 +022 Test Valve for Reheat Stop Valves B8
MAX51 AA201 Solenoid Valve for Control Fluid
MAX62AA001 Overspeed Trip Test Device C4 Supply during Test B3
KA01 Valve for Test oil C4
KA02 Valve for Auxiliary Start-up Fluid C4 MAX51AA202 Solenoid Valve for Control Fluid
KA03 Valve For Auxiliary Trip Fluid C4 Supply During Test B4
KA001M Electrical Motor C4
MAX52AA001 Remote Trip Solenoid C2
MAX62CG001 B Limit Switch, up-Normal position ATT C4
C Limit Switch, Down- Test Position ATT C4 MAX52AA002 Remote Trip Solenoid C2

MAX62CP501 Pressure Gauge, Test Oil Overspeed D1 MAX53AA051 Solenoid Valve for Sequential
Trip Water Injection C13
MAY10
AA001 +002 Overspeed Trip E2 MAX61AA201 Solenoid Valve for Changeover from
KA01 Releasing Device E2 Trip Fluid to Control Fluid C3




MAY10
CG001 +002 C Limit Switch, Alarm E3
E Limit Switch Alarm ATT E3







5.1-0681-02/4

Power Plant iden- Title Coor-
tification System dinete

MAX61
AA211 +212 Solenoid Valve for Testing of
Main Stop Valves C5,6

MAX61
AA221 +222 Solenoid Valve for Testing of
Reheat Stop Valves C8



LBS42 CP002 Differential Pressure Monitor for
Extraction Check Valve-A4
(Batron -Cell) B11




MAG01CP201 Pressure Switch, low-Vacuum Trip,
Vacuum min. B4

MAG01CP202 Pressure Switch, low-Vacuum Trip,
Vacuum max. B4

MAG01CP203 Pressure Switch, low-Vacuum Trip,
Vacuum min. B5

MAG01CP204 Pressure Switch, low-Vacuum Trip
Vacuum max. B5

MAG10CP011 Pressure Switch, Electrical Low
Vacuum Trip.
Signal Pressure to high E13

MAG 10CP012 Pressure Switch, Electrical low
Vacuum Trip, Alarm E13

MAG10CP013 Pressure Switch Electrical low Vacuum
Trip Interlocking MAG10CPO12 E14

MAG10CP016 Pressure Switch for Energizing of
Vacuum Breaker E13

MAX45 CP211 Pressure Switch For Reheat Control
Valves Secondary Fluid E2

MAX48 CP201 Pressure Switch For Auxiliary C2
Start-up Fluid



Power Plant iden- Title Coor-
tification System dinete

MAX48 CP202 Pressure Switch for Auxiliary
Start-up Fluid Between Solenoid
Valves MAX48AA201 and202 B1

MAX51
CP001 +002 Pressure transmitter for Trip fluid A1

MAX51
CP205 +206 Pressure Switch for Trip Fluid Between
Solenoid Valves MAX51 AA201
and 202 B3

MAX51
CP207 +208 Pressure Switch for Trip Fluid Ahead of
Changeover Valve MAX51 A211 B3

MAX51
CP209 +210 Pressure Switch for Trip Fluid Ahead of
Changeover Valve MAX51 AA211 B2,3

MAX51CP 221 Pressure Switch for Trip Fluid ahead of
+226 Main Stop Valve, Test Valve B6

MAX51CP222 Pressure Switch for Pressure above
+227 Piston of Main Stop Vale B7

MAX51 CP223 Pressure Switch for Pressure below
+228 Piston Disc of Main Stop Vale A7

MAX51CP242 Pressure Switch for Trip Fluid above
+247 Piston of Reheat Stop Valve A9

MAX51 CP243 Pressure Switch for Trip Fluid Below
+248 Piston Disc of Reheat Stop Valve B9

MAX52CP211 Pressure Switch for Auxiliary
Trip Fluid B3

MAX62 CP 211 Pressure Switch for Test oil of
overspeed Trip max D1

MAX62 CP 212 Pressure Switch for Test oil of
overspeed Trip max. D1

MAX62 CP 213 Pressure Switch for Test oil of
overspeed Trip Pressure Collapsed D2

MAX45 AA031 Pressure Converter for IP secondary
Oil E4
5.1-0681-02/5

Potrebbero piacerti anche