Sei sulla pagina 1di 1

VENTILATION SERVICES - Aspire Academy & Highfurlong School, Blackpool

Key:

REV A - 30/07/13

ROOM
NO.

ROOM NAME

FLOOR
REF

Design criteria obtained from RDS/Architectural Layouts


Design criteria assumed
Design criteria from BB102
Design criteria confirmed via FF&E layouts

LOCATION

ROOM AREA

Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 1
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 1
Block 2
Block 2
Block 2
Block 2
Block 2
Block 2
Block 1
Block 2
Block 2
Block 2

m2
12.00
3.00
3.00
3.00
3.00
3.00
10.00
3.00
3.00
3.00
3.00
3.00
8.00
6.00
11.00
5.00
11.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
16.00
6.00
22.00
23.00
5.00
36.90
16.90
16.90
7.00
22.00
22.00
5.00

No.
PEOPLE

ROOM
HEIGHT

ROOM
VOLUME

MECH
ACH

VENT
RATE

REQ'D
VENT RATE
Duty

L/S/P

L/s
83.33
20.83
20.83
20.83
20.83
20.83
69.44
20.83
20.83
20.83
20.83
20.83
55.56
45.83
76.39
34.72
76.39
20.83
20.83
20.83
20.83
20.83
20.83
20.83
20.83
20.83
20.83
111.11
41.67
152.78
159.72
34.72
160.00
100.00
100.00
48.61
152.78
152.78
34.72

2.80
0-603
0-604
0-605
0-606
0-607
0-608
0-610
0-611
0-612
0-614
0-615
0-616
0-617
0-802
0-803
0-804
0-805
0-807
0-808
0-809
0-810
0-811
0-812
0-813
0-814
0-815
0-816
0-908
1-801
1-802
1-803
1-804
2-001B
2-002
2-003
2-801
2-802
2-803
2-804

Change
WC
WC
Shower
Shower
Shower
Change
WC
WC
Shower
Shower
Shower
Accessible Change
Acc WC
WC
Acc WC
WC
Shower
Shower
Shower
Shower
Shower
Shower
Shower
Shower
Shower
Shower
Store
Acc WC
WC
WC
Acc WC
Open Plan Office
Meeting
Meeting
Acc WC
WC
WC
Acc WC

Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 00
Level 01
Level 01
Level 01
Level 01
Level 02
Level 02
Level 02
Level 02
Level 02
Level 02
Level 02

16
10
10

m
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.85
2.85
2.85
2.50
2.50
2.50
2.50

m3
30.00
7.50
7.50
7.50
7.50
7.50
25.00
7.50
7.50
7.50
7.50
7.50
20.00
15.00
27.50
12.50
27.50
7.50
7.50
7.50
7.50
7.50
7.50
7.50
7.50
7.50
7.50
40.00
15.00
55.00
57.50
12.50
105.17
48.17
48.17
17.50
55.00
55.00
12.50

10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
11.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00
10.00

VENT SYSTEM

PLANT ROOM

ESTIMATED
COOLING LOAD

NO

60.00
W/m

2214.00
1014.00
1014.00