0 valutazioniIl 0% ha trovato utile questo documento (0 voti)
637 visualizzazioni35 pagine
This document provides configuration parameters and their value ranges for planning a 2G BSS network using Huawei equipment, including parameters for cells, handover control, carrier configuration, system information, call control, and handover thresholds. It includes tables for configuration of items like BSC cell parameters, frequency hopping data, system information, alarm thresholds, and handover control data with explanations of the supported parameter ranges.
Descrizione originale:
DETAILED DESCRIPTION OF HUAWEI 2G PARAMETERS FOR OPTIMIZATION ENGINEERS
This document provides configuration parameters and their value ranges for planning a 2G BSS network using Huawei equipment, including parameters for cells, handover control, carrier configuration, system information, call control, and handover thresholds. It includes tables for configuration of items like BSC cell parameters, frequency hopping data, system information, alarm thresholds, and handover control data with explanations of the supported parameter ranges.
This document provides configuration parameters and their value ranges for planning a 2G BSS network using Huawei equipment, including parameters for cells, handover control, carrier configuration, system information, call control, and handover thresholds. It includes tables for configuration of items like BSC cell parameters, frequency hopping data, system information, alarm thresholds, and handover control data with explanations of the supported parameter ranges.
1 Local Office 2 Site 3 Cell 4 Handover 5 Power Control 6 Channel Huawei 2G BSS Network Planning Parameters Parameters Range BSC Cell Table Cell System Type GSM900,GSM1800 Sub cell Type Normal, Upper Layer, Lower Layer Cell Class Mediium, Upper , Lower Layer BCC 0-7 NCC 0-7 CGI MCC:3,MNC:2 to3,LAC:1 to 65535, CI: 0 to 65535 Support GPRS YES, NO Frequency Hopping Data Table FH Index No 0 to 65535 MA HSN 0 to 63 (0-cyclic hopping sequence, rest pseudo random) TSC 0-7 MAIO 0-N-1 N=number of TRX CH Type TCH full rate, TCH half rate 01, TCH half rate 0, SDCCH8, Main BCCH, Combined BCCH, BCH, BCCH+CBCH, SDCCH+CBCH, PBCCH+PDTCH, PCCCH+PDTCH, PDTCH, Dynamic PDTCH Default Value Unit Applied Value GSM900 Normal Upper Yes Parameters Carrier Configuration Table Static TRX Power class Carrier power type HW-IUO property TRX priority Antenna and Feeder Configuration Table Tower-mounted amplifier flag Power attenuation factor Range 0~13 Other BTS versions: The 0529 version or above of BTS30 supports static power class setting of level 0~10. All versions of BTS20 support the static power setting of levels 0~10; The microcell BTS supports the static power setting of levels 0~13. BTS 3001C supports the static power setting of level 0~13. 40W, 60W,Default OverLaid subcell, UnderLaid subcell, None Level 0~Level 7 Antenna and Feeder Configuration Table With tower-mounted amplifier, Without tower-mounted amplifier 0~255 Default Value Unit Applied Value 0 Default Level 0 In the case that BTS (including 2.0 and 3.0 base stations) adopts CDU, CDU gain should be adjusted according to the two parameters described above. Parameters System Information Table System Information Regular transmission Regular transmission interval MS MAX retrans Common access control class Special access control class Cell channel description format ATT PWRC UL DTX CBA CBQ EC allowed Call re-establishment allowed NCC permitted CCCH-CONF Tx-integer BS_AG_BLKS_RES BS-PA-MFRAMS T3212 Radio Link Timeout MS_TXPWR_MAX_CCH RXLEV_ACCESS_MIN Half rate supported CRH CBCH CH Description CBCH mobile allocation ACS PI CRO TO PT ECSC Power deviation indication Power deviation MBR Cell Configuration Data Table Data service allowed Speech version Speech version priority Encryption algorithm BCCH mutual support FH Mode SMCBC DRX DL DTX BCCH mutual recovery BBFH TRX mutual support BBFH TRX mutual recover Cell Attribute Table Interf. band Thrsh. 0 Interf. band Thrsh. 1 Interf. band Thrsh. 2 Interf. band Thrsh. 3 Interf. band Thrsh. 4 Interf. band Thrsh. 5 Interf. calculation period SACCH multi-frames Radio resource report period CCCH load indication period CCCH load Thrsh. Max resend times of Phy. Info. T3105 Overload indication period RACH busy Thrsh RACH min. access level Average RACH load TS number Max RC power reduction T200 SDCCH(5ms) T200 FACCH/F T200 FACCH/H T200 SACCH TCH SAPI0 T200 SACCH TCH SAPI3 T200 SACCH SDCCH T200 SDCCH SAPI3 MAX TA Frame start time Paging times Random access error Thrsh DC bias voltage Thrsh. Cell extension type Cell extension offset Cell Alarm Threshold Table Power output error Thrsh. Power output reduction Thrsh VSWR TRX error Thrsh VSWR TRX unadjusted Thrsh Cell Call Control Table TCH immediate assignment Immediate assignment Opt. Immediate assign to other cell Assign to other cell TCH assignment retry Intra-cell SD to TCH HO Inter-cell SD to TCH HO OM start intra-cell HO OM start inter-cell HO(intra-BSC) OM start inter-BSC HO TCH overload alarm RF CH abnormal release retry Abis flow control permitted TCH flow control allowed Circuit pool Direct retry Cell Call Control Parameter Table T3101 Assign-TCH idle rate Thrsh. Assign-TCH re-Estb. rate thrsh. TCH flow control start thrsh. Max assignment retry times Idle TCH Thrsh. for SD to TCH HO Max. radio CH release retry times Service type Req.(SD to TCH HO) Syst. delay frame No. adj. value Response on out BSC HO Req. Range 1~13. 2bis, 2ter, 5bis, 5ter, 10bis YES,NO 0~255 1,2,4,7 Level 0~9 forbidd Level 11~15 forbidden Bitmap, 1024, 512, 256, 128, Variable-length YES,NO YES,NO Allowed, Mandatory, Forbidden YES(0), NO (1) YES(1), NO (0) YES,NO YES,NO 0 allowed~7 allowed 1 non-combined CCCH, 1 combined CCCH, 2 non-combined CCCHs, 3 non- combined CCCHs, and 4 non-combined CCCHs. 3~12, 14, 16, 20, 25, 32, 50 0~7 (non-combined BCCH), 0~2 (1 combined CCCH), 2~9 0~255 4~64, with a step-length of 4 0~20 0~63, (-110dBm~-47dBm) YES,NO 0~14 YES,NO YES(1), NO (0) 0~63. Corresponding level value: 0~126db. 0~7. The corresponding value: 0~60db and 7 corresponds to Infinite 0~31. The corresponding time is 20~620s, 31 is a reserve value used to change the effect of the CRO on C2. YES,NO YES,NO 0~3. The corresponding values: 0db. 2db. 4db. 6dB 0~3 NT 12K FULL RATE, NT 12K HALF RATE, NT 12K, NT 6K, T 9.6K, T 4.8K, T 2.4K, T 1.2K, T 600 BITS and T 1200/75 Support full rate version 1, support full rate version 2, support full , support half version 2 and rate version 3 support half rate version 3rate version 1,support half rate Support full rate version 1, support full rate version 2, support full , support half version 2 and rate version 3 support half rate version 3rate version 1,support half rate version 2, and support half rate version 3. Not supporting encryption, A5/1~A5/7 YES,NO Not FH, baseband FH, RF FH YES,NO YES,NO Switchback during resource check, Immediate switchback, No switchback YES,NO Switchback during resources check, immediate switchback, no switchback 110~85 110~85 110~85 110~85 110~85 110~85 1~31 0~255 0~255 0~255 0~100 1~255 1~255 0~255 0~63, (-110dBm~-47dBm) 0~255 0~65535 0~255 1~255 1~255 1~255 1~255 1~255 1~255 1~255 0~255 0~65535 0~255 0~255 1~255 Normal cell, Single timeslot extended cell, Dual timeslot extended cell 0~35 0~9, indicating -10dB~-1dB respectively 0~18 0~18 0~18 YES,NO YES,NO YES,NO YES,NO YES,NO YES,NO YES,NO YES,NO YES,NO YES,NO YES,NO YES,NO YES,NO YES,NO Value range: select circuit pool, deselect circuit pool, system automatic selection YES,NO 3~50 0~100 0~100 0~7 0~3 0~100 0~3 MSC service request, Location updating request, Paging response, MSC service re- establishment request, Unknown 0 YES,NO Default Value Unit 1~6. 2bis, 2ter, 5bis, 5ter YES 10 Times 0 0 Bitmap YES YES Mandatory YES NO YES YES 111111 Non-combined CCCH 20 RACH timeslot (equals to a TDMA frame, 4.615ms) 2 (non-combined CCCH), 1 (combined CCCH) Block 2 CCCH multiframes 20~30 (urban), 10~20 (suburb), 8~10 (mountains) 6 minutes 52 SACCH period (480ms) 5(900M), 0(1800M) Grade 8 (-102dBm) Grade No 4 2dB NO YES 0 2dB 0 0 NO NO 1 0 0 111000 Support full rate version 1 10000000 YES Not FH NO YES No switchback for timeslot FH, Switchback during resources check for other FHs and non-FH. Yes for timeslot FH, No for the non-timeslot FH. No switchback for FH timeslot, Switchback during resources check for non-timeslot FH. fixed as 110 dBm 105 dBm 98 dBm 90 dBm 87 dBm fixed as 85 dBm 20 SACCH period (480ms) 31 SACCH period (480ms) 10 Sec 15 Sec 80 % 30 times 7 10ms 15 sec 5 (BTS20, BTS22C), 16 (BTS3X) Grade 5 Grade 5000 timeslot number 5 2dB 60 5ms 50 5ms 50 5ms 150 5ms 200 5ms 60 5ms 60 5ms 62 for normal cell, 63 for single TS extended cell, and 219 for dual TS extended cell. bit period (1 bit = 0.55km) 65535 Frame Number 1 times 180 0 dB Normal Cell 0(normal cell),34(single TS extended cell) km 2 2 2 2 NO NO NO YES NO YES YES YES YES YES YES YES NO NO select circuit pool function YES 30 100ms 80 % 80 % 2 Idle TCH timeslot in a cell 2 times 80 % 1 times MSC service request 0 YES Applied Value Parameters Range Handover Control Data Table HO algorithm Huawei handover algorithm, GSM0508 handover algorithm Min interval for TCH HOs 1~60 Min interval for SD HOs 1~60 Min interval for consecutive HOs 1~60 Min interval for Emerg. HOs 1~60 Co-BSC/MSC Adj YES,NO SD HO allowed YES,NO Penalty allowed YES,NO Intra-cell HO allowed YES,NO Load HO allowed YES,NO MS fast moving HO allowed YES,NO Rx_Level_Drop HO allowed YES,NO PBGT HO allowed YES,NO MS power prediction after HO YES,NO MR. Pre-process YES,NO Transfer original MR. YES,NO Transfer BS/MS power class YES,NO Sent Freq.of preprocessed MR. Do not report, Twice every second , Once every second,Once every 2 sec,One every 4 sec Cell Description Table Layer of the cell 1~4, which are respectively corresponding to the PICO layer,MICRO layer, MACRO layer, and UMBRELLA layer Cell priority 1~16 Inter-layer HO Thrsh. 0~63(-110dBm~-47dBm) Inter-layer HO hysteresis 0~63 Penalty on fast moving HO 0~63 Penalty time on fast moving HO 0~255 Min DL level on candidate cell 0~63. (-110dBm~-47dBm). MS_TXPWR_MAX_CCH 0~31 UL expected level at HO access 0~63. (-110dBm~-47dBm) Cell Type Normal Cell,Concentric cell Adjancent Cell Relation Table Ncell ID 0~255 for internal cells, and 0~799 for external cells. PBGT HO Thrsh. 0~127, corresponding to -64~63dB Inter-cell HO hysteresis 0~63 Min access level offset 0~63 Filter Data Table Allowed MR number lost 0~32 Filter length for TCH level 1~32 Filter length for TCH Qual. 1~32 Filter length for SD level 1~32 Filter length for SD Qual 1~32 Filter length for Ncell RX_LEV 1~32 Filter length for TA 1~32 Penalty table Penalty level after HO fail. 0~63 Penalty time after HO fail 0~60 Penalty level after BQ HO Fail 0~63 Penalty time after BQ HO Fail. 0~60 Penalty time after TA HO Fail 0~63 Penalty time after TA HO Fail. 0~60 Penalty time after IUO HO Fail. 0~16 Emergency Handove Table TA Thrsh. 0~255 DL Qual. Thrsh. 0~70, corresponding to RQ (quality level 0~7)*10 UL Qual. Thrsh. 0~70, corresponding to RQ (quality level 0~7)*10 UL Qual. Thrsh. for interf. HO 0~70, corresponding to RQ (quality level 0~7)*10 DL Qual. Thrsh. for interf. HO 0~70, corresponding to RQ (quality level 0~7)*10 UL RX_LEV Thrsh. for interf. HO 0~63. (-110dBm~-47dBm) DL RX_LEV Thrsh. for interf. HO 0~63. (-110dBm~-47dBm) Uplink level SHTM filter length 0~20 Filter parameters A1~A8 0~20 Filter parameter B 0~255 MIN TA 0~63 Load Handover Table System flux Thrsh. for load HO 0, 8~11; its corresponding percentage values: 0, 70, 80, 90, 95 Load HO Thrsh. 0~7. Its corresponding percentage values: 0, 50, 60, 70, 75, 80,85,90 Load Req. on candidate cell 0~7. Its corresponding percentage values: 0, 50, 60, 70, 75, 80,85,90 Load HO bandwidth 0~63 Load HO step period 1~60 Load HO step level 1~60 Normal Handover Data Table Edge HO UL RX_LEV Thrsh. 0~63. (-110dBm~-47dBm) Edge HO DL RX_LEV Thrsh 0~63. (-110dBm~-47dBm) Edge HO watch time 1~16 Edge HO valid time 1~16 PBGT watch time 1~16 PBGT valid time 1~16 Layer HO watch time 1~16 Layer HO valid time 1~16 MS Fast Moving HO Data Table MS Fast-moving Watch cells 1~10 MS Fast-moving Valid cells 1~10 MS Fast-moving time Thrsh. 0~255 Intra-cell Handover Data Table MAX consecutive HO times 1~20 Forbidden time after MAX times 1~200 Interval for consecutive HO Jud. 1~200 HW-IUO Handover Table UO signal intensity difference 0~63 RX-LEV Thrsh. 0~63 RX-LEV Hysteresis 0~63 TA Thrsh. 0~63 TA hysteresis 0~63 UO HO watch time 0~16 UO HO valid time 0~16 Assign optimum layer System optimization, UnderLaid subcell, OverLaid subcell, No Perence Assign-optimum-level thrsh. 0~63,(-110dBm~-47dBm) Pref. subcell in HO of intra-BSC System Optimization, OverLaid Subcell, UnderLaid Subcell, No IntraBSC inc-cell HO Pref. Alg. YES,NO Incoming-to-BSC HO optimum layer UnderLaid subcell, OverLaid subcell, No preference Default Value Unit Applied Values Huawei handover algorithm 6 sec 2 Sec 6 sec 6 sec YES NO YES NO YES NO NO YES NO NO NO YES Twice Every Second 3 Layer 1 Grade 25 Grade 3 dB 30 dB 40 Second 15 Grade 5(900M),0(1800M) 35 Grade Normal Cell 68 for popular urban areas, 72 for suburbs. 4dB populous urban areas and 8dB for suburts dB 0 dB 4 Number of MRs 6 6 3 3 6 6 30 dB 10 sec 63 dB 10 sec 63 dB 10 sec 10 sec 63(Normal cell), 219(Dual timeslot extension cell) bit period 60 60 50 50 25 grade 30 grade 3 10 0 0 Bit period 10 % 5 % 2 % 25 dB 10 Sec 5 dB 25 for urban areas without PBGT handover being grade 30 for urban areas without PBGT handover being grade 5 Sec 4 Sec 5 Sec 5 Sec 5 Sec 5 Sec 3 2 15 Sec 3 20 Sec 6 Sec dB 25 grade 3 dB bit period. 1 bit period corresponds to 0.55km bit period, 1 bit period corresponding to 0.55km 5 Sec 4 Sec System Optimization dBm Underlaid Subcell YES UnderLaid subcell Lowest Value 7791.928 Parameters Range Power Control Selection Table PC algorithm HW_1.HW_2 UL PC allowed YES,NO DL PC allowed YES,NO Ordinary Cell PC Table RX_LEV Thrsh. for UL increase 0~63. (-110dBm~-47dBm) RX_LEV Thrsh. for DL increase 0~63. (-110dBm~-47dBm) P1 1~32 N1 1~32 RX_LEV Thrsh. for UL decrease 0~63(-110dBm~-47dBm) RX_LEV Thrsh. for DL decrease 0~63(-110dBm~-47dBm) P2 1~32 N2 1~32 Qual. Thrsh. for UL increase 0~7 Qual. Thrsh. for DL increase 0~7 P3 1~32 N3 1~32 Qual. Thrsh. for UL decrease 0~7 Qual. Thrsh. for DL decrease 0~7 P4 1~32 N4 1~32 BTS Power Control Data Table Power control adjustment period 1~10 Expected stable downlink signal strength 0~63 Downlink signal strength filter length 1~32 Downlink path loss compensation factor 0~100 Expected downlink quality 0~7 Downlink quality filter length 1~32 Downlink quality compensating factor 0~100 Minimum base station transmitting power 0~36 Maximum power control adjustment step-length 1~16 Maximum base station transmitting power 1~58 Base station power control level 1~16,corresponding to 0dB-30dB MS power control data table Registering period 1~30 Expected initial signal strength 0~63 Filter length at the initial adjustment phase 1~32 Expected stable state signal strength 0~63 Stable stage signal filter length 1~32 Uplink compensation factor 1~100 Expected uplink quality 0~7 Quality filter length at stable stage 1~30 Uplink quality compensating factor 0~100 Power raising range after handover failure 0~4 Maximum power control adjusting step-length 1~16 HW II power control data table Power control adjustment period 1~30 Uplink level filter length 1~20 Downlink level filter length 1~20 Uplink quality filter length 1~20 Downlink quality filter length 1~20 Measuring report compensation switch YES,NO Number of predicted uplink MRs 0~3 Number of predicted downlink MRs 0~3 Uplink signal strength upper threshold 0~63 Uplink signal strength lower threshold 0~63 Uplink signal good quality threshold 0~7 Uplink signal bad quality threshold 0~7 Downlink signal strength upper threshold 0~63 Downlink signal strength lower threshold 0~63 Downlink signal good quality threshold 0~7 Downlink signal bad quality threshold 0~7 Maximum allowed adjustment step-length in quality band 0 0~30 Maximum allowed adjustment step-length in quality band 1 0~30 Maximum allowed adjustment step-length in quality band 2 0~30 Allowed adjustment step-length for power control according to quality 0~4 Minimum allowed power of MS 0~20 Maximum allowed power of MS 0~20 Maximum transmit power of base station 1~58 Level Number of base station power control 1~16,corresponding to 0dB-30dB Default Value Unit Applied HW_2 YES YES 20 Grade 20 Grade 12 10 40 Grade 40 Grade 12 10 5 Grade 5 Grade 7 5 0 Grade 0 Grade 18 15 5 SACCH Period (480ms) 35 Grade 5 80 % 1 Grade 5 20 % 4 dBm 8 Grade,2dB at each level 46(macro cell),36(22c),39(3001C) dBm 16 Grade,every level corresponding to 2dB 5 SACCH Period (480ms) 30 Grade 2 30 Grade 5 80 Indicate when the difference between the current level and the % 1 Grade 6 20. Indicate the difference between the current quality and the ideal % 2 Grade,every level corresponding to 2dB 8 Grade,every level to 2dB 5 SACCH Period (480ms) 6 6 6 6 YES 2 Number of Mrs 2 Number of Mrs 35 Grade 25 Grade 0 Grade 2 Grade 40 Grade 30 Grade 0 Grade 2 Grade 16 dB 8 dB 4 dB 4 dB 19(900M), 15(1800M) Power Level 5(900M), 0(1800M) Grade 46 (macro cell), 36(BTS22C), 39(BTS3001C) dBm 16 Grade Parameters Range Default Value Channel distribution algorithm selection Huawei I algorithms and Huawei II algorithms Huawei I algorithms Interference band pre-processing switch YES,NO NO Initial length of interference band filter 0~7 3 Length of averaged interference band 0~31 6 Whether SDCCH is dynamically distributed YES,NO YES Idle SDCCH channel threshold 2 The maximum number of SDCCH channel in the cell specifying the maximum number of SDCCH in the cell. Configured SDCCH in the cell + 8 (too big a value will not be good for system recovery during abnormality) TCH Minimum recovery time (second) 60~3600 600 TCH Idle threshold N1 0~cell TCH timeslot number 2 TCH decision application period T (minute) 0~65535 10 HW II Channel Allocation table SD allocation priority allowed YES,NO YES iInterf. priority allowed YES,NO YES Active Ch Inter.Meas. allowed YES,NO YES AllocationTRX priority allowed YES,NO YES History records priority allowed YES,NO YES Balancetraffic allowed YES,NO YES Interf.of UL Level thrsh. 0~31 31 Interf. of UL qual. Thrsh. 0~70 40 Interf. of DL Level Thrsh. 0~63 31 Interf. of DL Qua. Thrsh. 0~70 40 Filter length for TCH Level 1~32 6 Filter length for TCH Qual. 1~32 6 Filter length for SDCCH Level 1~32 2 Filter length for SDCCH Qual. 1~32 2 Update Period of CH Record 1~1440 30 Update Freq. Of CH record 0~63 2 Radio channel management control table Unit Applied Values Sec Min Grade Quality grade value Grade Quality grade value Minutes