Sei sulla pagina 1di 35

Data Configuration Manual

Huawei 2G BSS Network Planning Parameters


1 Local Office
2 Site
3 Cell
4 Handover
5 Power Control
6 Channel
Huawei 2G BSS Network Planning Parameters
Parameters Range
BSC Cell Table
Cell System Type GSM900,GSM1800
Sub cell Type Normal, Upper Layer, Lower Layer
Cell Class Mediium, Upper , Lower Layer
BCC 0-7
NCC 0-7
CGI MCC:3,MNC:2 to3,LAC:1 to 65535, CI: 0 to 65535
Support GPRS YES, NO
Frequency Hopping Data Table
FH Index No 0 to 65535
MA
HSN 0 to 63 (0-cyclic hopping sequence, rest pseudo random)
TSC 0-7
MAIO 0-N-1 N=number of TRX
CH Type
TCH full rate, TCH half rate 01, TCH half rate 0, SDCCH8, Main
BCCH, Combined BCCH, BCH, BCCH+CBCH, SDCCH+CBCH,
PBCCH+PDTCH, PCCCH+PDTCH, PDTCH, Dynamic PDTCH
Default Value Unit Applied Value
GSM900
Normal
Upper
Yes
Parameters
Carrier Configuration Table
Static TRX Power class
Carrier power type
HW-IUO property
TRX priority
Antenna and Feeder Configuration Table
Tower-mounted amplifier flag
Power attenuation factor
Range
0~13
Other BTS versions:
The 0529 version or above of BTS30 supports static power class setting of level 0~10.
All versions of BTS20 support the static power setting of levels 0~10;
The microcell BTS supports the static power setting of levels 0~13.
BTS 3001C supports the static power setting of level 0~13.
40W, 60W,Default
OverLaid subcell, UnderLaid subcell, None
Level 0~Level 7
Antenna and Feeder Configuration Table
With tower-mounted amplifier, Without tower-mounted amplifier
0~255
Default Value Unit Applied Value
0
Default
Level 0
In the case that BTS
(including 2.0 and 3.0 base
stations) adopts CDU, CDU
gain should be adjusted
according to the two
parameters described
above.
Parameters
System Information Table
System Information
Regular transmission
Regular transmission interval
MS MAX retrans
Common access control class
Special access control class
Cell channel description format
ATT
PWRC
UL DTX
CBA
CBQ
EC allowed
Call re-establishment allowed
NCC permitted
CCCH-CONF
Tx-integer
BS_AG_BLKS_RES
BS-PA-MFRAMS
T3212
Radio Link Timeout
MS_TXPWR_MAX_CCH
RXLEV_ACCESS_MIN
Half rate supported
CRH
CBCH CH Description
CBCH mobile allocation
ACS
PI
CRO
TO
PT
ECSC
Power deviation indication
Power deviation
MBR
Cell Configuration Data Table
Data service allowed
Speech version
Speech version priority
Encryption algorithm
BCCH mutual support
FH Mode
SMCBC DRX
DL DTX
BCCH mutual recovery
BBFH TRX mutual support
BBFH TRX mutual recover
Cell Attribute Table
Interf. band Thrsh. 0
Interf. band Thrsh. 1
Interf. band Thrsh. 2
Interf. band Thrsh. 3
Interf. band Thrsh. 4
Interf. band Thrsh. 5
Interf. calculation period
SACCH multi-frames
Radio resource report period
CCCH load indication period
CCCH load Thrsh.
Max resend times of Phy. Info.
T3105
Overload indication period
RACH busy Thrsh
RACH min. access level
Average RACH load TS number
Max RC power reduction
T200 SDCCH(5ms)
T200 FACCH/F
T200 FACCH/H
T200 SACCH TCH SAPI0
T200 SACCH TCH SAPI3
T200 SACCH SDCCH
T200 SDCCH SAPI3
MAX TA
Frame start time
Paging times
Random access error Thrsh
DC bias voltage Thrsh.
Cell extension type
Cell extension offset
Cell Alarm Threshold Table
Power output error Thrsh.
Power output reduction Thrsh
VSWR TRX error Thrsh
VSWR TRX unadjusted Thrsh
Cell Call Control Table
TCH immediate assignment
Immediate assignment Opt.
Immediate assign to other cell
Assign to other cell
TCH assignment retry
Intra-cell SD to TCH HO
Inter-cell SD to TCH HO
OM start intra-cell HO
OM start inter-cell HO(intra-BSC)
OM start inter-BSC HO
TCH overload alarm
RF CH abnormal release retry
Abis flow control permitted
TCH flow control allowed
Circuit pool
Direct retry
Cell Call Control Parameter Table
T3101
Assign-TCH idle rate Thrsh.
Assign-TCH re-Estb. rate thrsh.
TCH flow control start thrsh.
Max assignment retry times
Idle TCH Thrsh. for SD to TCH HO
Max. radio CH release retry times
Service type Req.(SD to TCH HO)
Syst. delay frame No. adj. value
Response on out BSC HO Req.
Range
1~13. 2bis, 2ter, 5bis, 5ter, 10bis
YES,NO
0~255
1,2,4,7
Level 0~9 forbidd
Level 11~15 forbidden
Bitmap, 1024, 512, 256, 128, Variable-length
YES,NO
YES,NO
Allowed, Mandatory, Forbidden
YES(0), NO (1)
YES(1), NO (0)
YES,NO
YES,NO
0 allowed~7 allowed
1 non-combined CCCH, 1 combined CCCH, 2 non-combined CCCHs, 3 non-
combined CCCHs, and 4 non-combined CCCHs.
3~12, 14, 16, 20, 25, 32, 50
0~7 (non-combined BCCH), 0~2 (1 combined CCCH),
2~9
0~255
4~64, with a step-length of 4
0~20
0~63, (-110dBm~-47dBm)
YES,NO
0~14
YES,NO
YES(1), NO (0)
0~63. Corresponding level value: 0~126db.
0~7. The corresponding value: 0~60db and 7 corresponds to Infinite
0~31. The corresponding time is 20~620s, 31 is a reserve value used to change the
effect of the CRO on C2.
YES,NO
YES,NO
0~3. The corresponding values: 0db. 2db. 4db. 6dB
0~3
NT 12K FULL RATE, NT 12K HALF RATE, NT 12K, NT 6K, T
9.6K, T 4.8K, T 2.4K, T 1.2K, T 600 BITS and T 1200/75
Support full rate version 1, support full rate version 2, support full , support half
version 2 and rate version 3 support half rate version 3rate version 1,support half
rate
Support full rate version 1, support full rate version 2, support full , support half
version 2 and rate version 3 support half rate version 3rate version 1,support half
rate version 2, and support half rate version 3.
Not supporting encryption, A5/1~A5/7
YES,NO
Not FH, baseband FH, RF FH
YES,NO
YES,NO
Switchback during resource check, Immediate switchback, No switchback
YES,NO
Switchback during resources check, immediate switchback, no switchback
110~85
110~85
110~85
110~85
110~85
110~85
1~31
0~255
0~255
0~255
0~100
1~255
1~255
0~255
0~63, (-110dBm~-47dBm)
0~255
0~65535
0~255
1~255
1~255
1~255
1~255
1~255
1~255
1~255
0~255
0~65535
0~255
0~255
1~255
Normal cell, Single timeslot extended cell, Dual timeslot extended cell
0~35
0~9, indicating -10dB~-1dB respectively
0~18
0~18
0~18
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
Value range: select circuit pool, deselect circuit pool, system automatic selection
YES,NO
3~50
0~100
0~100
0~7
0~3
0~100
0~3
MSC service request, Location updating request, Paging response, MSC service re-
establishment request, Unknown
0
YES,NO
Default Value Unit
1~6. 2bis, 2ter, 5bis, 5ter
YES
10
Times
0
0
Bitmap
YES
YES
Mandatory
YES
NO
YES
YES
111111
Non-combined CCCH
20
RACH timeslot (equals to a TDMA frame,
4.615ms)
2 (non-combined CCCH), 1 (combined CCCH) Block
2 CCCH multiframes
20~30 (urban), 10~20 (suburb), 8~10 (mountains) 6 minutes
52 SACCH period (480ms)
5(900M), 0(1800M) Grade
8 (-102dBm) Grade
No
4 2dB
NO
YES
0 2dB
0
0
NO
NO
1
0
0
111000
Support full rate version 1
10000000
YES
Not FH
NO
YES
No switchback for timeslot FH, Switchback during
resources check for other FHs and non-FH.
Yes for timeslot FH, No for the non-timeslot FH.
No switchback for FH timeslot, Switchback during
resources check for non-timeslot FH.
fixed as 110 dBm
105 dBm
98 dBm
90 dBm
87 dBm
fixed as 85 dBm
20 SACCH period (480ms)
31 SACCH period (480ms)
10 Sec
15 Sec
80 %
30 times
7 10ms
15 sec
5 (BTS20, BTS22C), 16 (BTS3X) Grade
5 Grade
5000 timeslot number
5 2dB
60 5ms
50 5ms
50 5ms
150 5ms
200 5ms
60 5ms
60 5ms
62 for normal cell, 63 for single TS extended cell, and
219 for dual TS extended cell.
bit period (1 bit = 0.55km)
65535 Frame Number
1 times
180
0 dB
Normal Cell
0(normal cell),34(single TS extended cell) km
2
2
2
2
NO
NO
NO
YES
NO
YES
YES
YES
YES
YES
YES
YES
NO
NO
select circuit pool function
YES
30 100ms
80 %
80 %
2 Idle TCH timeslot in a cell
2 times
80 %
1 times
MSC service request
0
YES
Applied
Value
Parameters Range
Handover Control Data Table
HO algorithm Huawei handover algorithm, GSM0508 handover algorithm
Min interval for TCH HOs 1~60
Min interval for SD HOs 1~60
Min interval for consecutive HOs 1~60
Min interval for Emerg. HOs 1~60
Co-BSC/MSC Adj YES,NO
SD HO allowed YES,NO
Penalty allowed YES,NO
Intra-cell HO allowed YES,NO
Load HO allowed YES,NO
MS fast moving HO allowed YES,NO
Rx_Level_Drop HO allowed YES,NO
PBGT HO allowed YES,NO
MS power prediction after HO YES,NO
MR. Pre-process YES,NO
Transfer original MR. YES,NO
Transfer BS/MS power class YES,NO
Sent Freq.of preprocessed MR.
Do not report, Twice every second , Once every second,Once
every 2 sec,One every 4 sec
Cell Description Table
Layer of the cell
1~4, which are respectively corresponding to the PICO
layer,MICRO layer, MACRO layer, and UMBRELLA layer
Cell priority 1~16
Inter-layer HO Thrsh. 0~63(-110dBm~-47dBm)
Inter-layer HO hysteresis 0~63
Penalty on fast moving HO 0~63
Penalty time on fast moving HO 0~255
Min DL level on candidate cell 0~63. (-110dBm~-47dBm).
MS_TXPWR_MAX_CCH 0~31
UL expected level at HO access 0~63. (-110dBm~-47dBm)
Cell Type Normal Cell,Concentric cell
Adjancent Cell Relation Table
Ncell ID 0~255 for internal cells, and 0~799 for external cells.
PBGT HO Thrsh. 0~127, corresponding to -64~63dB
Inter-cell HO hysteresis 0~63
Min access level offset 0~63
Filter Data Table
Allowed MR number lost 0~32
Filter length for TCH level 1~32
Filter length for TCH Qual. 1~32
Filter length for SD level 1~32
Filter length for SD Qual 1~32
Filter length for Ncell RX_LEV 1~32
Filter length for TA 1~32
Penalty table
Penalty level after HO fail. 0~63
Penalty time after HO fail 0~60
Penalty level after BQ HO Fail 0~63
Penalty time after BQ HO Fail. 0~60
Penalty time after TA HO Fail 0~63
Penalty time after TA HO Fail. 0~60
Penalty time after IUO HO Fail. 0~16
Emergency Handove Table
TA Thrsh. 0~255
DL Qual. Thrsh. 0~70, corresponding to RQ (quality level 0~7)*10
UL Qual. Thrsh. 0~70, corresponding to RQ (quality level 0~7)*10
UL Qual. Thrsh. for interf. HO 0~70, corresponding to RQ (quality level 0~7)*10
DL Qual. Thrsh. for interf. HO 0~70, corresponding to RQ (quality level 0~7)*10
UL RX_LEV Thrsh. for interf. HO 0~63. (-110dBm~-47dBm)
DL RX_LEV Thrsh. for interf. HO 0~63. (-110dBm~-47dBm)
Uplink level SHTM filter length 0~20
Filter parameters A1~A8 0~20
Filter parameter B 0~255
MIN TA 0~63
Load Handover Table
System flux Thrsh. for load HO
0, 8~11; its corresponding percentage values: 0, 70, 80, 90,
95
Load HO Thrsh.
0~7. Its corresponding percentage values: 0, 50, 60, 70, 75,
80,85,90
Load Req. on candidate cell
0~7. Its corresponding percentage values: 0, 50, 60, 70, 75,
80,85,90
Load HO bandwidth 0~63
Load HO step period 1~60
Load HO step level 1~60
Normal Handover Data Table
Edge HO UL RX_LEV Thrsh. 0~63. (-110dBm~-47dBm)
Edge HO DL RX_LEV Thrsh 0~63. (-110dBm~-47dBm)
Edge HO watch time 1~16
Edge HO valid time 1~16
PBGT watch time 1~16
PBGT valid time 1~16
Layer HO watch time 1~16
Layer HO valid time 1~16
MS Fast Moving HO Data Table
MS Fast-moving Watch cells 1~10
MS Fast-moving Valid cells 1~10
MS Fast-moving time Thrsh. 0~255
Intra-cell Handover Data Table
MAX consecutive HO times 1~20
Forbidden time after MAX times 1~200
Interval for consecutive HO Jud. 1~200
HW-IUO Handover Table
UO signal intensity difference 0~63
RX-LEV Thrsh. 0~63
RX-LEV Hysteresis 0~63
TA Thrsh. 0~63
TA hysteresis 0~63
UO HO watch time 0~16
UO HO valid time 0~16
Assign optimum layer
System optimization, UnderLaid subcell, OverLaid subcell, No
Perence
Assign-optimum-level thrsh. 0~63,(-110dBm~-47dBm)
Pref. subcell in HO of intra-BSC System Optimization, OverLaid Subcell, UnderLaid Subcell, No
IntraBSC inc-cell HO Pref. Alg. YES,NO
Incoming-to-BSC HO optimum layer UnderLaid subcell, OverLaid subcell, No preference
Default Value Unit Applied Values
Huawei handover
algorithm
6 sec
2 Sec
6 sec
6 sec
YES
NO
YES
NO
YES
NO
NO
YES
NO
NO
NO
YES
Twice Every Second
3 Layer
1 Grade
25 Grade
3 dB
30 dB
40 Second
15 Grade
5(900M),0(1800M)
35 Grade
Normal Cell
68 for popular urban
areas, 72 for suburbs.
4dB populous urban
areas and 8dB for
suburts
dB
0 dB
4 Number of MRs
6
6
3
3
6
6
30 dB
10 sec
63 dB
10 sec
63 dB
10 sec
10 sec
63(Normal cell),
219(Dual timeslot
extension cell)
bit period
60
60
50
50
25 grade
30 grade
3
10
0
0 Bit period
10 %
5 %
2 %
25 dB
10 Sec
5 dB
25 for urban areas
without PBGT
handover being
grade
30 for urban areas
without PBGT
handover being
grade
5 Sec
4 Sec
5 Sec
5 Sec
5 Sec
5 Sec
3
2
15 Sec
3
20 Sec
6 Sec
dB
25 grade
3 dB
bit period. 1 bit
period corresponds to
0.55km
bit period, 1 bit
period corresponding
to 0.55km
5 Sec
4 Sec
System Optimization
dBm
Underlaid Subcell
YES
UnderLaid subcell
Lowest
Value
7791.928
Parameters Range
Power Control Selection Table
PC algorithm HW_1.HW_2
UL PC allowed YES,NO
DL PC allowed YES,NO
Ordinary Cell PC Table
RX_LEV Thrsh. for UL increase 0~63. (-110dBm~-47dBm)
RX_LEV Thrsh. for DL increase 0~63. (-110dBm~-47dBm)
P1 1~32
N1 1~32
RX_LEV Thrsh. for UL decrease 0~63(-110dBm~-47dBm)
RX_LEV Thrsh. for DL decrease 0~63(-110dBm~-47dBm)
P2 1~32
N2 1~32
Qual. Thrsh. for UL increase 0~7
Qual. Thrsh. for DL increase 0~7
P3 1~32
N3 1~32
Qual. Thrsh. for UL decrease 0~7
Qual. Thrsh. for DL decrease 0~7
P4 1~32
N4 1~32
BTS Power Control Data Table
Power control adjustment period 1~10
Expected stable downlink signal strength 0~63
Downlink signal strength filter length 1~32
Downlink path loss compensation factor 0~100
Expected downlink quality 0~7
Downlink quality filter length 1~32
Downlink quality compensating factor 0~100
Minimum base station transmitting power 0~36
Maximum power control adjustment step-length 1~16
Maximum base station transmitting power 1~58
Base station power control level 1~16,corresponding to 0dB-30dB
MS power control data table
Registering period 1~30
Expected initial signal strength 0~63
Filter length at the initial adjustment phase 1~32
Expected stable state signal strength 0~63
Stable stage signal filter length 1~32
Uplink compensation factor 1~100
Expected uplink quality 0~7
Quality filter length at stable stage 1~30
Uplink quality compensating factor 0~100
Power raising range after handover failure 0~4
Maximum power control adjusting step-length 1~16
HW II power control data table
Power control adjustment period 1~30
Uplink level filter length 1~20
Downlink level filter length 1~20
Uplink quality filter length 1~20
Downlink quality filter length 1~20
Measuring report compensation switch YES,NO
Number of predicted uplink MRs 0~3
Number of predicted downlink MRs 0~3
Uplink signal strength upper threshold 0~63
Uplink signal strength lower threshold 0~63
Uplink signal good quality threshold 0~7
Uplink signal bad quality threshold 0~7
Downlink signal strength upper threshold 0~63
Downlink signal strength lower threshold 0~63
Downlink signal good quality threshold 0~7
Downlink signal bad quality threshold 0~7
Maximum allowed adjustment step-length in quality
band 0
0~30
Maximum allowed adjustment step-length in quality
band 1
0~30
Maximum allowed adjustment step-length in quality
band 2
0~30
Allowed adjustment step-length for power control
according to quality
0~4
Minimum allowed power of MS 0~20
Maximum allowed power of MS 0~20
Maximum transmit power of base station 1~58
Level Number of base station power control 1~16,corresponding to 0dB-30dB
Default Value Unit Applied
HW_2
YES
YES
20 Grade
20 Grade
12
10
40 Grade
40 Grade
12
10
5 Grade
5 Grade
7
5
0 Grade
0 Grade
18
15
5 SACCH Period (480ms)
35 Grade
5
80 %
1 Grade
5
20 %
4 dBm
8 Grade,2dB at each level
46(macro cell),36(22c),39(3001C) dBm
16
Grade,every level
corresponding to 2dB
5 SACCH Period (480ms)
30 Grade
2
30 Grade
5
80 Indicate when the difference
between the current level and the
%
1 Grade
6
20. Indicate the difference between
the current quality and the ideal
%
2
Grade,every level
corresponding to 2dB
8
Grade,every level to
2dB
5 SACCH Period (480ms)
6
6
6
6
YES
2 Number of Mrs
2 Number of Mrs
35 Grade
25 Grade
0 Grade
2 Grade
40 Grade
30 Grade
0 Grade
2 Grade
16 dB
8 dB
4 dB
4 dB
19(900M), 15(1800M) Power Level
5(900M), 0(1800M) Grade
46 (macro cell), 36(BTS22C),
39(BTS3001C)
dBm
16 Grade
Parameters Range Default Value
Channel distribution algorithm selection
Huawei I algorithms and Huawei
II algorithms
Huawei I algorithms
Interference band pre-processing switch YES,NO NO
Initial length of interference band filter 0~7 3
Length of averaged interference band 0~31 6
Whether SDCCH is dynamically distributed YES,NO YES
Idle SDCCH channel threshold 2
The maximum number of SDCCH channel in
the cell
specifying the maximum number
of SDCCH in the cell.
Configured SDCCH in
the cell + 8 (too big a
value will not be
good for system
recovery during
abnormality)
TCH Minimum recovery time (second) 60~3600 600
TCH Idle threshold N1 0~cell TCH timeslot number 2
TCH decision application period T (minute) 0~65535 10
HW II Channel Allocation table
SD allocation priority allowed YES,NO YES
iInterf. priority allowed YES,NO YES
Active Ch Inter.Meas. allowed YES,NO YES
AllocationTRX priority allowed YES,NO YES
History records priority allowed YES,NO YES
Balancetraffic allowed YES,NO YES
Interf.of UL Level thrsh. 0~31 31
Interf. of UL qual. Thrsh. 0~70 40
Interf. of DL Level Thrsh. 0~63 31
Interf. of DL Qua. Thrsh. 0~70 40
Filter length for TCH Level 1~32 6
Filter length for TCH Qual. 1~32 6
Filter length for SDCCH Level 1~32 2
Filter length for SDCCH Qual. 1~32 2
Update Period of CH Record 1~1440 30
Update Freq. Of CH record 0~63 2
Radio channel management control table
Unit
Applied
Values
Sec
Min
Grade
Quality grade
value
Grade
Quality grade
value
Minutes

Potrebbero piacerti anche