Sei sulla pagina 1di 139

MENU

Change Note Forms


WCDMA BTS WN6.0 MP1 (WN6.0 19.5-179)

Nokia Siemens Networks

1(139)

MENU

WCDMA BTS CN-id: WN60034

Title: Memory leak in BTS, causing spontaneous BTS restart Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA BTS References:

Reason for the Change Note: Problem: Memory leak in BTS, causing spontaneous BTS restart.

Root cause: ALMAG (antenna line management) was not ready to handle bad case in device scanning. It occurs when devices on one antenna line with address assignment still replies on scanning messages. It leads to very high and expanded binary tree which consumed more and more memory. Correction: The correction is that there could be max 20 devices on one antenna line, binary tree height is 152, so no it might be 20 * 152 = 3040 max scanning messages sent and scanning is stopped. Corrected Fault Reports: NA04697530 RU20 PILOT: 7786 - Memory leak in BTS Modified components: Component FORE_PARA_Pkg.sbs Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None Version um_eu_19#0.3

Nokia Siemens Networks

Company Confidential

2 (139)

MENU

Customer Impact: Capacity & Performance: Occasional service outage due to BTS autonomous restart

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

3 (139)

MENU

WCDMA BTS CN-id: WN60035

Title: C_NBAP and D_NBAP in BL after NPGEP switchover Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: C_NBAP and D_NBAP in BL after NPGEP switchover Root cause: GARP from the second NPGEP card was not reaching FTM's kernel. Hence, FTM was not using the correct MAC to send traffic to RNC. Correction: Problem corrected

Corrected Fault Reports: 48188ESPE01: After more than 50 BFD created NPGEP SWO will cause BFD about 10 seconds down NA04691601: RU20 Pilot: C_NBAP and D_NBAP move in BL after NPGEP switchover on Iub over IP BTS Modified components: Component FTM6.0 Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None Customer Impact: Capacity & Performance: Decreased HSUPA success rate
Nokia Siemens Networks Company Confidential

Version FTM_A60_MP1_174.01

4 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results: -

Nokia Siemens Networks

Company Confidential

5 (139)

MENU

WCDMA BTS CN-id: WN60036

Title: Cyclic BTS restart after WN6.0 CD0.2 upgrade Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Cyclic BTS restart after WN6.0 CD0.2 upgrade Root cause: Problem in Telecom SW. R&D parameter handling not working correctly. Missing handling of CC&S notification for R&D parameter value change. Description of the correction: Added handling of CC&S notification for R&D parameter value change. Corrected Fault Reports: NA04700335 RU20 Pilot VF-IT: cyclic site restart after WN6.0 CD0.2 upgrade Modified components: Component sctenv.c ParamCacheHandler.c Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None Customer Impact: Capacity & Performance: Decreased HSUPA success rate Version 1612 1612

Nokia Siemens Networks

Company Confidential

6 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results: -

Nokia Siemens Networks

Company Confidential

7 (139)

MENU

WCDMA BTS CN-id: WN60037

Title: 40w power license missing alarm Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: 40W power license missing Root cause: License handling problem in BTS O&M SW. Incorrect licensing faults were reported to operator during BTS operation. Description of the correction: License handling corrected Corrected Fault Reports: NA04699256: 40w power licence missing Modified components: Component OPT.sbs Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None Customer Impact: Operability & Maintenance: 40w power license missing alarm active. BTS restart needed for recovery. Version f_19#0.48

Nokia Siemens Networks

Company Confidential

8 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results: -

Nokia Siemens Networks

Company Confidential

9 (139)

MENU

WCDMA BTS CN-id: WN60038

Title: EUBB: Wrong source "no connection unit (0010)" alarm Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): UltraSite WCDMA BTS References:

Reason for the Change Note: Problem: EUBB: Wrong source for "no connection unit (0010)" alarm after extracting ethernet cable from WAM side. Description of the fault: Because of bug O&M SW, virtual WAMF was added to HWF and it caused fault ID 10 to WAMF. However the correct fault in this case is "WSMF-WAM Interconnection Failure Description of the correction: HW file handling is changed so that virtual WAMF is not added to it anymore. Corrected Fault Reports: PR NA04685491 RU20 Pilot EUBB VF-IT: Issue047 Wrong source "no connection unit (0010)" alarm Modified components: Component FORE_PARA_Pkg.sbs Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None Customer Impact: Operability & Maintenance: Wrong alarm is seen on site manager view. Version um_eu_19#0.3

Nokia Siemens Networks

Company Confidential

10 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results: -

Nokia Siemens Networks

Company Confidential

11 (139)

MENU

WCDMA BTS CN-id: WN60039

Title: Several blocking alarms after upgrade to WN6.0 19.5-106. Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA BTS References:

Reason for the Change Note: Problem: Several blocking alarms after upgrade to WN6.0 19.5-106 (system module, FRIA or cell faulty alarm) Root cause: Invalid memory reference in BTS O&M SW Correction: Invalid memory reference corrected. Corrected Fault Reports: NA04696553: Several sites needed a BTS reset to clear system module, FRIA or cell faulty alarms. Modified components: Component CONF_pkg.sbs Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None Customer Impact: Capacity & Performance: Degraded cell availability Version f_19#0.5

Nokia Siemens Networks

Company Confidential

12 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results: -

Nokia Siemens Networks

Company Confidential

13 (139)

MENU

WCDMA BTS CN-id: WN60040

Title: EUBB: WSPF logs missing from BSTechreport. Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA BTS References:

Reason for the Change Note: Problem: WSPF logs missing from BSTechreport Root cause: In EUBB, the client asking recoveries may run on different board than the server that makes the actual recovery actions. This was not taken into account during the implementation. Due to this messaging problem runtime logs, DSP dumps etc for most WSP/Faraday related faults fails. Correction: O&M implementation modified so that the recovery requests and replies are now sent correctly via SWBUS. Corrected Fault Reports: 60926ESPE04: EUBB: RU20 Pilot: WSPF logs missing from BSTechreport Modified components: Component TECHREP.sbs Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None Customer Impact: Version um_eu_19#0.4

Nokia Siemens Networks

Company Confidential

14 (139)

MENU

Operability & Maintenance: Troubleshooting affected as the WSPF logs are missing from BSTechreport.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results: -

Nokia Siemens Networks

Company Confidential

15 (139)

MENU

WCDMA BTS CN-id: WN60041

Title: Cell not established when all aal2 links are down. Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): UltraSite WCDMA BTS References:

Reason for the Change Note: Problem: Cell not established when all aal2 links are down. Error 16649 The Node B does not have sufficient resources available. Root cause: Telecom does not count DCH capable rakes from WAMs where all aal2 links are down. Cell establishment fails due to lack of resources. Correction: DCH capable rakes are taken into account from WAMs where all aal2 links are down Corrected Fault Reports: NA04699870 Failure in WCELL unblock after IFGE0 NPGEP status change Modified components: Component 3g_cell_and_wam_mapping.spd SeekHsdpaWam.spd CountDchCapableRakes.spd full.itex Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None
Nokia Siemens Networks Company Confidential

Version 2258 2258 2258 2258

16 (139)

MENU

Customer Impact: Capacity & Performance: Cell not established when all aal2 links are down Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results: -

Nokia Siemens Networks

Company Confidential

17 (139)

MENU

WCDMA BTS CN-id: WN60042

Title: HSDPA resource problem Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA BTS References:

Reason for the Change Note: Problem: HSDPA resource problem caused by hanging users Root cause: When TCOM received information from DSP that some user is hanging, and this user was not found in our internal database, TCOM in such a case tried to delete another user Correction: Do not try to delete user when it is not found in internal TCOM database. Corrected Fault Reports: 60522ESPE04 RU20 Pilot TMO: HSDPA resources problem Modified components: Component 3grlcontroller.spr Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None Customer Impact: Capacity & Performance: HDSPA performance degradation due to hanging users in the BTS. Version 2326

Nokia Siemens Networks

Company Confidential

18 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results: -

Nokia Siemens Networks

Company Confidential

19 (139)

MENU

WCDMA BTS CN-id: WN60043

Title: HSDPA resource problem Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA BTS References:

Reason for the Change Note: Problem: HSDPA resource problem caused by hanging users Root cause: Too much parallel RL reconfiguration process cause hanging resources in BTS because mechanism that was used to remember additional reconfiguration request was implemented incorrectly Correction: Mechanism that was mentioned above was corrected Corrected Fault Reports: 39189ESPE03 Hanging resources in RLH Modified components: Component StartLocalDeletions.spd 3grlcontroller.spr Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None Customer Impact: Capacity & Performance: HDSPA performance degradation due to hanging users in the BTS.
Nokia Siemens Networks Company Confidential

Version 2366 2366

20 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results: -

Nokia Siemens Networks

Company Confidential

21 (139)

MENU

WCDMA BTS CN-id: WN60046

Title: New functionality: CR1580 Improved tolerance for ATM Iub interruptions.

Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station. References:

Reason for the Change Note: Reason for change: Customer request Change description: Interval, which after Iub link status failure is detected after a transmission interruption, has been increased from 7 to 14 s. Corrected Fault Reports: CN4174: CR1580 Improved tolerance for Iub interruptions

Modified components: Component WN6.0 PP0.1 Version WN6.0 PP0.03

Change effects: Effects on end-user Effects on Operator NOTE! Compatibility change: WN6.0 PP0.1 (MP1) is not compatible with AXC 6.0 (BL-77.01) or older AXC SW versions. AXC 6.0 PP0.1 (BL-81) is not compatible with WN6.0 MP0 (19.5-115) or older WBTS SW versions.

Nokia Siemens Networks

Company Confidential

22 (139)

MENU

Summary: WN6.0 PP0.1 (MP1) and AXC 6.0 PP0.1 (BL-81) must be taken into use at the same time. Other effects

New functionality YES Customer Impact: Capacity & Performance: Cell availability: Interval, which after Iub link status failure is detected after a transmission interruption, has been increased from 7 to 14 s.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

23 (139)

MENU

WCDMA BTS CN-id: WN60049

Title: 7772 HSDPA CONFIGURATION FAILED ALARM Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Root cause: Problem in BTS telecom SW. Due to current DCH user allocation rules the user re-allocations are not done in a way where there would be always enough DSP capacity to setup the HSDPA cell when BTS is in operational mode. Correction: Implemented mechanism for moving DCH users between FSP cards to make room for HSDPA cell creation during normal BTS operation when BTS is handling DCH load. Corrected Fault Reports: NA04688725 RU20 Pilot: 7772 HSDPA CONFIGURATION FAILED ALARM Modified components: Component SeekHsdpaWamRelease2.spd grm3g.spt Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality
Nokia Siemens Networks Company Confidential

Version 2272 2272

24 (139)

MENU

None

Customer Impact: Capacity & Performance: No HSDPA traffic, 7772 HSDPA CONFIGURATION FAILED ALARM active Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

25 (139)

MENU

WCDMA BTS CN-id: WN60050

Title: M5001 HSUPA CE consumption counter problem Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA BTS References:

Reason for the Change Note: Problem: M5001 HSUPA CE consumption counter doe not work correctly. Root cause: Incorrect maximum value of consumed CEs by hsupa. Throughput of HSUPA user wasn't taken into account when calculating the used CEs. In case of HSUPA user who consumes 2 Cluster Fractions only one was reported. Correction: Telecom RL handler sends information to Recourse Manager indicating if HSUPA user can use more than 1 Cluster Fraction. Corrected Fault Reports: 66527ESPE02 RU20 Pilot: M5001 FlexiBTS Counters: Counters for HSUPA CE consumption do not count correctly Modified components: Component h2sdl_newLRM.c Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality
Nokia Siemens Networks Company Confidential

Version 2349

26 (139)

MENU

None Customer Impact: Capacity & Performance: M5001 HSUPA CE consumption counter doe not work correctly. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

27 (139)

MENU

WCDMA BTS CN-id: WN60051

Title: EUBB: WAMF is visible in Site information instead of WSMF Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: WAMF is visible in Site information instead of WSMF Root cause: WAMF was written in CurrentBD xml by mistake instead of WSMF. Correction: Checking unit type in writeXMLCurrentBD and replace WAMF to WSMF if needed. Corrected Fault Reports: 60707ESPE04 EUBB: WAMF is visible in Site information Modified components: Component FORE_FCM_Pkg.sbs Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None Customer Impact: Operability & Maintenance: Incorrect unit type visible in Site information.
Nokia Siemens Networks Company Confidential

Version um_eu_19#0.14

28 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

29 (139)

MENU

WCDMA BTS CN-id: WN60052

Title: Re-commissioning of B type sector configuration does not work when 15MHz spacing is exceeded in case of FRIA Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: Re-commissioning of B type sector configuration does not work when 15MHz spacing is exceeded in case of FRIA Root cause: Incorrect property value in BTS Property file for Filter TX and RX spacing in case of FRIA. This incorrect value became visible in B type sector configuration when 15MHz spacing was exceeded. Correction: Property value has been changed for FRIA from 15MHz to 40MHz Corrected Fault Reports: NA04711829 Problems using Site Manager SW V 6.1.85 Modified components: Component BPF f_19#0.47 Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None
Nokia Siemens Networks Company Confidential

Version um_eu_19#0.14

30 (139)

MENU

Customer Impact: Operability & Maintenance: Re-commissioning of B type sector configuration does not work when 15MHz spacing is exceeded in case of FRIA

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

31 (139)

MENU

WCDMA BTS CN-id: WN60053

Title: CPC: RadioLinkReconfigurationFailure cause "not-enough-user-plane-processingresources" Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: CPC: RadioLinkReconfigurationFailure cause "not-enough-user-planeprocessing-resources" Root cause: CPC parameters without DL DRX parameterts are not supported by L2 DSP SW. Correction: Added support for CPC without DL DRX. Corrected Fault Reports: 39227ESPE03 CPC: RadioLinkReconfigurationFailure cause " not-enough-user-plane-processingresources" Modified components: Component CodecResourceManagerMc.pcs Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality
Nokia Siemens Networks Company Confidential

Version wn60mp1_19#19.2

32 (139)

MENU

None

Customer Impact: Capacity & Maintenance: KPI degradation & Radio Link Reconfiguration Failures when CPC is activated. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

33 (139)

MENU

WCDMA BTS CN-id: WN60054

Title: DSP unit autonomous restart with Flexi Rel2 system Module. Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: DSP unit autonomous restart with Flexi Rel2 system Module. Root cause: Memory leak in codec DSP SW Correction: Memory leak corrected. Corrected Fault Reports: 61615ESPE04 DSP failure with Flexi Rel2 Modified components: Component L1Transmission.pcs Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None Version wn60mp1_19#19.3

Nokia Siemens Networks

Company Confidential

34 (139)

MENU

Customer Impact: Capacity & Performance: Capacity degradation & dropped calls due to DSP unit autonomous restart. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

35 (139)

MENU

WCDMA BTS CN-id: WN60055

Title: FSPC unit autonomous reset during HSPA HO testing Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: FSPC unit autonomous reset during HSPA HO testing Root cause: Several F-DPCH reconfigurations cause hanging F-DPCH parameters causing eventually FSPC unit autonomous restart. Correction: F-DPCH parameters are released after successful F-DPCH to DCH reconfiguration Corrected Fault Reports: 62179ESPE04 FSPC unit autonomous reset during HSPA HO testing Modified components: Component 3grlcontroller.spr Change effects: Effects on end-user: Effects on Operator: Other effects None New functionality None Version 2925

Nokia Siemens Networks

Company Confidential

36 (139)

MENU

Customer Impact: Capacity & Performance: Capacity degradation & dropped calls due to FSPC unit autonomous restart. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

37 (139)

MENU

WCDMA BTS CN-id: WN60056

Title: RET settings missing after BTS Site Test AISG 1.1 Antenna line devices affected. Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: RET settings missing after BTS Site Test AISG 1.1 Antenna line devices affected. Root cause: Antenna line management problem BTS O&M SW. Problem occurs when making calibration to RET devices with "old" TILT value. Correction: Antenna line management problem BTS O&M SW corrected. Corrected Fault Reports: NA04701681 Wrong function at BTS-Site-Test - RET settings missing NA04697710 Tilt Values change sporadically without Operator Touch Modified components: Component Version ALMAG_MGMT_Pkg.sbs _lt_19#0.3

Change effects: Effects on end-user Effects on Operator Other effects

Nokia Siemens Networks

Company Confidential

38 (139)

MENU

New functionality None Customer Impact: Capacity & Performance: KPI degradation due to lost RET Tilt values.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

39 (139)

MENU

WCDMA BTS CN-id: WN60057

Title: Extension System Module autonomous restart Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Extension System Module autonomous restart Root cause: Memory leak problem in BTS O&M SW. Memory leak leads eventually to the situation where memory allocation request fails and extension system module is automatically restated. Correction: Memory leak corrected. Corrected Fault Reports: NA04704534::FSME is lost, resulting in insufficient resources NA04709801 RU20 Pilot:WBTS_Alarm_7651_FSME_Failure in optical RP3 interface on RAN12U NA04710475 RU20 Pilot: M1002C518 _ UL_DCH_SEL_BTS_HW_BGR affected due to alarm on extension Modified components: Component FORE_Monitor_pkg.sbs FSP_Agent_pkg.sbs Version f_lt_td_19#0.2 f_19#0.17

Change effects: Effects on end-user Effects on Operator


Nokia Siemens Networks Company Confidential

40 (139)

MENU

Other effects

New functionality

Customer Impact: Capacity & Performance: Cell availability and call drops due extension system module autonomous restart

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

41 (139)

MENU

WCDMA BTS CN-id: WN60058

Title: Problems with NodeB SCF Provisioning Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Step by step commissioning needed if warnings appear in commissioning file prevalidation Root cause: If warnings found during commissioning file pre-validation user needs to go through the commissioning instead of just pressing send button. Correction: Warning does not prevent the sending of the commissioning file. Corrected Fault Reports: NA04676282 Several issues with NodeB SCF Provisioning Modified components: Component btsmanager sitemgr Version 6.1.90 3.0.x

Change effects: Effects on end-user Effects on Operator Other effects

New functionality None

Nokia Siemens Networks

Company Confidential

42 (139)

MENU

Customer Impact: Operability & Maintenance: Commissioning consumes more time Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

43 (139)

MENU

WCDMA BTS CN-id: WN60059

Title: Incorrect FSM extension module connection port LED status. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: After installing FSMD expansion module, the port status led in the extension module stays amber while the port status led in main module goes green. Root cause: Problem in O&M SW. Certain LED rules were not applied to Extension module. Correction: All LED rules applied to Extension module. Corrected Fault Reports: NA04711769: FSM expansion module connection port LED status incorrect Modified components: Component UHND_StatusDisplay.sbs Version f_lt_19#0.4

Change effects: Effects on end-user Effects on Operator Other effects

New functionality None Customer Impact: Operability & Maintenance: Misleading LED status

Nokia Siemens Networks

Company Confidential

44 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

45 (139)

MENU

WCDMA BTS CN-id: WN60060

Title: HSUPA WSPC failure after Iub link break Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: HSUPA WSPC failure after the Iub link break. Root cause: Problem in TUP SW. Problem is caused by incorrect function usage after Iub link break. This can cause occasional DSP failures in HSUPA WSP unit resulting WSP unit autonomous restart and the No connection to unit, WSP alarm. Correction: Function usage corrected by TUP SW. Corrected Fault Reports: 39584ESPE03 HSUPA WSP failed with "No Connection to WSPC" alarm Modified components: Component svn Version 1342

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Customer Impact:
Nokia Siemens Networks Company Confidential

46 (139)

MENU

Capacity & Performance, temporary capacity degradation and dropped calls due to WSPC unit autonomous restart. No connection to unit, WSP alarm visible. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

47 (139)

MENU

WCDMA BTS CN-id: WN60061

Title: Antenna line device failure alarm Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: RET alarm Not calibrated, HW error and Antenna line device failure alarm is raised when RET is calibrated without installed antenna. RET alarm is correctly cancelled after calibrating with installed antenna but Antenna line device failure alarm remains active. Root cause: Fault handling problem in O&M antenna line management. Correction: Fault handling corrected. Corrected Fault Reports: NA04695288 RET Error (Not calibrated, HW error) cleared but "Antenna line device failure (1847)" ALM not cleared Modified components: Component ALMAG_MGMT.sbs Version f_lt_19#0.4

Change effects: Effects on end-user Effects on Operator Other effects

New functionality
Nokia Siemens Networks Company Confidential

48 (139)

MENU

Customer Impact: Operation & Maintenance: Antenna line device failure alarm active. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

49 (139)

MENU

WCDMA BTS CN-id: WN60062

Title: RET mechanical angle value goes to 0 after min angle or max angle has been changed. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: When RET min angle or max angle has been changed, RET indicates error code "Unknown procedure". In addition, mechanical angle value has automatically changed to 0.0. Root cause: Parameter handling problem in BTS O&M Antenna line management. Correction: Parameter handling problem corrected. Corrected Fault Reports: NA04695223: RU20 pilot: RET MachinAngle value becomes 0 that RET MinAngle/MaxAngle(Read-only parameter) setting Modified components: Component ALMAG_MGMT.sbs Version f_lt_19#0.4

Change effects: Effects on end-user Effects on Operator Other effects New functionality None Customer Impact:
Nokia Siemens Networks Company Confidential

50 (139)

MENU

Operation & Maintenance: RET mechanical angle value goes to 0 after min angle or max angle has been changed. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

51 (139)

MENU

WCDMA BTS CN-id: WN60063

Title: Some M5001 counters are not showing correct values. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Average value for the used DL and UL CEs reported as much bigger than the max available CE value. Root cause: CE calculation problem in BTS Telecom SW. Correction: CE calculation problem corrected and protection to prevent the sending of improper values implemented. Corrected Fault Reports: NA04713561: M5001 C7, C8 count 5965232 RU20 Modified components: Component grm3g.spd Version 3352

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Customer Impact:
Nokia Siemens Networks Company Confidential

52 (139)

MENU

Counters: Average value for the used DL and UL CEs reported as much bigger than the max available CE value. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

53 (139)

MENU

WCDMA BTS CN-id: WN60064

Title: Not possible to set channel spacing to max when FRIA selected Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Not possible to set channel spacing to max when FRIA selected Root cause: BTS Site manager used outdated BTS property file. Correction: Replication script updated in order to use up-to-date BTS property. Corrected Fault Reports: NA04716590: Problems using Site Manager SW V 6.1.89 Modified components: Component run.btsproperties.sh Version 1.0

Change effects: Effects on end-user Effects on Operator Other effects New functionality None Customer Impact: Operation & Maintenance: Not possible to set channel spacing to max when FRIA selected.
Nokia Siemens Networks Company Confidential

54 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

55 (139)

MENU

WCDMA BTS CN-id: WN60065

Title: Key combination ALT+S in Site Manager window Cert. Management is used twice Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: The key combination (shortcut) ALT + S is used twice in the window Certificate Management within the Site Manager WN6.0. Therefore the key combination cannot be used to steer the Site Manager. Root cause: Duplicate shortcut definition in BTS Site Manager. Correction: All shortcut definitions corrected to be unique Corrected Fault Reports: NA04705357: Key combination ALT+S in Site Manager window Cert. Management is used twice Modified components: Component Poseidon Version 4.0.64

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Nokia Siemens Networks

Company Confidential

56 (139)

MENU

Customer Impact: Operation & Maintenance: Certain key combinations cannot be used to steer the BTS Site Manager. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

57 (139)

MENU

WCDMA BTS CN-id: WN60066

Title: VSWR threshold view doesn't work properly in BTS Site Manager Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Occasionally, user can not check the VSWR threshold values with BTS Site Manager. Root cause: Dialog size was defined incorrectly to be as fixed. Correction: Dialog size definition corrected Corrected Fault Reports: PR 48887ESPE01: VSWR Threshold view doesn't work properly Modified components: Component btsmanager.jar Version 6.1.64

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Customer Impact:

Nokia Siemens Networks

Company Confidential

58 (139)

MENU

Operation & Maintenance: VSWR threshold view doesn't work properly in BTS Site Manager. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

59 (139)

MENU

WCDMA BTS CN-id: WN60067

Title: Flexi Rel2 System Module or DSP Unit autonomous reset. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: DSP Unit autonomous reset as recovery action or BTS autonomous reset as recovery action. Root cause: Problem in RAKE DSP SW. Slot indication missing from the first frame after synchronous reconfiguration. This problem causes the buffer handling problem inside the Rake DSP SW leading to the Flexi Rel2 System Module or DSP Unit autonomous reset. Correction: Slot indication problem corrected. Corrected Fault Reports: NA04705743: 7652 Unit autonomous reset as recovery action or BTS autonomous reset as recovery action alarms Modified components: Component W1FingerDespreader.pcs Version wn60mp1_19#19.1

Change effects: Effects on end-user Effects on Operator Other effects

Nokia Siemens Networks

Company Confidential

60 (139)

MENU

New functionality

Customer Impact: Capacity & Performance: Temporary capacity degradation and dropped calls due to the Flexi Rel2 System Module or DSP Unit autonomous reset Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

61 (139)

MENU

WCDMA BTS CN-id: WN60068

Title: EUBB: WSPF lost with high traffic load. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: WSPF unit gets lost with high traffic load. Root cause: SW bus handling problem in BTS O&M SW causing time out during the data base operation. This was caused by the incorrect definition for maximum number of simultaneous SW bus users. Correction: SW bus handling problem corrected. Corrected Fault Reports: 60488ESPE04 EUBB: WSPF lost, Timeout during DB operation Modified components: Component swb_def.h Version um_f_w_8#0.3

Change effects: Effects on end-user Effects on Operator Other effects

New functionality None

Nokia Siemens Networks

Company Confidential

62 (139)

MENU

Customer Impact: Capacity & Performance: Capacity degradation and dropped calls. WSPF out of use. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

63 (139)

MENU

WCDMA BTS CN-id: WN60069

Title: Problems in sites equipped with WTRA and 2 carriers Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: After commissioning reconfiguration 2nd WTRA of each sector is stays down. Wcells stays in BL(I) state and with alarm "Cell power parameter out of range". Root cause: BTS O&M SW problem with TX cabling configuration due to incorrect Site Configuration File conversion. Problem visible with shared WPA configurations. Correction: TX cabling conversion corrected Corrected Fault Reports: NA04713087 Problems in sites equipped with WTRA and 2 carriers Modified components: Component FORE_CDM_Pkg.sbs Version um_19#0.12

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Customer Impact:
Nokia Siemens Networks Company Confidential

64 (139)

MENU

Capacity & Performance: After commissioning reconfiguration 2nd WTRA of each sector is stays down. Wcells stays in BL(I) state and with alarm "Cell power parameter out of range". Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

65 (139)

MENU

WCDMA BTS CN-id: WN60070

Title: WBTS sleeping after WSPF block/unblock Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: WBTS sleeping after WSPF block/unblock. Root cause: BTS O&M does not enable the downlink after WSPF unblock. Correction: BTS O&M enables the downlink after WSPF unblock Corrected Fault Reports: NA04717650: WBTS sleeping after WSPF block/unblock Modified components: Component BBC_pkg.sbs Version eu_19#0.4

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Customer Impact: Capacity & Performance: Sleeping cell without alarms. No calls possible after WSPF block/unblock
Nokia Siemens Networks Company Confidential

66 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

67 (139)

MENU

WCDMA BTS CN-id: WN60071

Title: Configuration FRKA with 2RF does not work. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Any sub configuration for 2+2+2 doesn't work with FRKA Root cause: REL2.1 FR is not covered in all antenna mapping tables. Correction: REL2.1 FR added to be covered in all antenna mapping tables. Corrected Fault Reports: NA04717522 Cell Configuration in the Configuration FRKA 2RF not start Modified components: Component BBC_pkg.sbs Version f_19#0.15

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Customer Impact: Capacity & Performance: Any sub configuration for 2+2+2 doesn't work with FRKA.

Nokia Siemens Networks

Company Confidential

68 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

69 (139)

MENU

WCDMA BTS CN-id: WN60072

Title: DSP unit autonomous restart inside the FSMD/E unit. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: DSP unit autonomous restart inside the FSMD/E unit after HSUPA 2ms TTI feature activated. Root cause: Rake DSP SW problem in RL reconfiguration process handling when 2ms TTI is active. This problem causes occasional Rake DSP unit autonomous restarts. Correction: RL reconfiguration process handling corrected. Corrected Fault Reports: 62167ESPE04: Faraday restarts Modified components: Component W1FingerDespreader.pcs Version wn60mp1_19#19.3

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Nokia Siemens Networks

Company Confidential

70 (139)

MENU

Customer Impact: Capacity & Performance: Temporary capacity degradation and dropped calls due to DSP unit autonomous restart. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

71 (139)

MENU

WCDMA BTS CN-id: WN60073

Title: AISG1.1 RET units missing from the commissioning data when updating SW from WN5.0 to WN6.0 with FRGG unit. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: 3 X FRGG+AISG1.1 RET in use. Second and third RET units are missed from commissioningData when updating sw from WN5.0 to WN6.0. Root cause: O&M SW problem with commissioning file conversion. Correction: Commissioning file conversion problem corrected Corrected Fault Reports: 40358ESPE03: 3 X FRGG+AISG1.1 RET, second and third RET units are missed from commissioningData when updated sw from WN5.0 to WN6.0 Modified components: Component FORE_CDM_Pkg.sbs Version f_lt_td_19#0.28

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Customer Impact
Nokia Siemens Networks Company Confidential

72 (139)

MENU

Operation & Maintenance, some of the AISG1.1 RET units missing from the commissioning data

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

73 (139)

MENU

WCDMA BTS CN-id: WN60074

Title: BTS internal SW management problem after SW upgrade Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: BTS internal SW management alarm after SW update and MHA's not detected. Root cause: Filter software download is too fast for radio modules with old filter SW that does not take flash aging into account. Correction: Filter SW download functionality optimized. Corrected Fault Reports: NA04708478: F11176 - After SW Update - BTS internal SW management problem NA04715853: BTS internal SW management problem (1850) -alarm from 2100 MHz WBTS Modified components: Component SWMAG.sbs Version f_19#0.4

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Nokia Siemens Networks

Company Confidential

74 (139)

MENU

Customer Impact: Operability & Maintenance: BTS internal SW management alarm after SW update and MHA's not detected.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

75 (139)

MENU

WCDMA BTS CN-id: WN60075

Title: Gigabit ethernet interface down after RU20 upgrade, WBTS out of use. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Gigabit ethernet interface down after RU20 upgrade, WBTS out of use. Root cause: Actual problem was caused by faulty wiring by the operator. Correction: Recovery added. HW PHY is capable of downgrading the ETH speed setting if 1000-BASE TX AN does not work. This was used. Corrected Fault Reports: 62387ESPE04: Gigabit ethernet interface down after RU20 upgrade Modified components: Component ml2Drv Version ip_rmu_ethernet_at_wirespeed_fix_a60_mp1

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Customer Impact:

Nokia Siemens Networks

Company Confidential

76 (139)

MENU

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

77 (139)

MENU

WCDMA BTS CN-id: WN60076

Title: Missing Ant ports define on F3 cells with diplexer setting when re-open the commissioning file via BTS Manager Version of the SW-build: WN6.0 PP0.1 (WN6.0 19.5-158_C) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Missing Ant ports define on F3 cells with diplexer setting when re-open the commissioning file via BTS Manager. Root cause: When doing reconfiguration, commissioning can not read the SCF correctly, cells with Y type configuration will be change to F type. Correction: In BTS site manager code, isolate the rule to determine whether an antenna is available for cell when user doing commissioning in UI from the rule that reading and validating SCF. Corrected Fault Reports: NA04715788: Missing Ant ports define on F3 cells with diplexer setting when re-open the commissioning file via BTS Manager Modified components: Component Version btsmanager.jarcommon.jar WN6.0 19.5-158 common.jar WN6.0 19.5-158

Change effects: Effects on end-user Effects on Operator Other effects

Nokia Siemens Networks

Company Confidential

78 (139)

MENU

New functionality

Customer Impact: Operability & Maintenance: Parameters need to be reinserted during recommissioning.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

79 (139)

MENU

WCDMA BTS CN-id: WN60077

Title: 71000 PM FTP Connection Failed alarms when upgrading to WN6.0 SW. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: 71000 PM FTP Connection Failed alarms when upgrading to WN6.0 SW. Root cause: A defect inside the FTM SMA Secure File Transfer which is also used for PM data transfer occurs when the transferred file is located on FCM (TFTP involved) and has a certain size (a multiple of 512 bytes). Correction: FTM SMA Secure File Transfer defect corrected. Corrected Fault Reports: NA04718312: RU20 Pilot: 71000 alarms from flexi BTS after MP0 Upgrade NA04708000: RU20 pilot VF-IT: Issue072, - Many Al 71000 PM FTP Connection Failed appear in RU20 Flexi WBTS NA04710638: HSPA counters NA04706960: RU20 Pilot:OMS Alarm 71000 PM FTP CONNECTION FAILED AFTER OMS UPGRADE CD0.3 Modified components: Component SMA Version sma_rdu_39203espe03_fix_a60

Change effects:

Nokia Siemens Networks

Company Confidential

80 (139)

MENU

Effects on end-user Effects on Operator Other effects

New functionality

Customer Impact: Operation & Maintenance, Many PM FTP CONNECTION FAILED alarms. Some of the M50XX counters may not be updated correctly

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

81 (139)

MENU

WCDMA BTS CN-id: WN60078

Title: Extremely high RTWP-values with RRH 60W Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: RRH 60W causes spontaneously extremely high RTWP-values. There is no service available when the problem is active. Root cause: Synthesis tool (Altera Quartus) implements a delay FIFO for the RX path in a wrong manner. Correction: The FPGA image with additional traces forces the synthesis tool to implement the delay FIFO correctly and in addition provides further debug traces if necessary. Corrected Fault Reports: NA04728141 O_PRM00389889A001 (Flexi NodeB: 60 W RRH failure, extremely RTWP values) Modified components: Component FRRH2_SW_60000090.lar Change effects: None Effects on end-user None Effects on Operator Other effects None New functionality Version 60000090

Nokia Siemens Networks

Company Confidential

82 (139)

MENU

Tracing functionality added for correction and troubleshooting purposes. See the correction description.

Customer Impact Capacity & Performance: In original problem, RRH 60W causes spontaneously extremely high RTWP-values. There is no service available when the problem is active.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

83 (139)

MENU

WCDMA BTS CN-id: WN60079

Title: Incorrect WCDMA loop test report indication Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: Incorrect WCDMA loop test report indication. A question mark visible in CDMA Test Loop report for WSPF3 Root cause: There was a question mark in CDMA Test Loop report for WSPF3. When it comes to generate CdmaRep.xml file with EUBB there was problem with parsing this file from BTS Site. Correction: Correct unit ID is now used during the parsing of CdmaRep.xml. Corrected Fault Reports: NA04694830 RU20 Pilot EUBB VF-IT: Issue055 Wrong WCDMA loop test report indication Modified components: Component Test.sbs Version um_eu_19#0.26

Change effects: Effects on end-user Effects on Operator Other effects

Nokia Siemens Networks

Company Confidential

84 (139)

MENU

New functionality

Customer Impact: Operability & Maintenance: Wrong WCDMA loop test result. A question mark visible in CDMA Test Loop report for WSPF3

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

85 (139)

MENU

WCDMA BTS CN-id: WN60081

Title: RRC setup failures due to BTS. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: RRC setup failures due to BTS. Root cause: Hanging user ID in the DSP SW. Problem happens after adding the two Radio Links for the existing user but other one fails. In this case DSP deletes the information from the both of the added RLs but sends the release request only to 1 RL. After this succeeded RL remains hanging in the DSP and following RL setups for with the same user id will be rejected. Correction: RL handling corrected in DSP SW Corrected Fault Reports: 40120ESPE03 Raw alarm 440 reported when next RLSSetup for the same user Modified components: Component W1SpTxCrCtrl.pcs Version wn60mp1_19#19.3

Change effects: Effects on end-user Effects on Operator Other effects

Nokia Siemens Networks

Company Confidential

86 (139)

MENU

New functionality None Customer Impact: Capacity & Performance: RRC setup failures due to BTS. BTS restart needed for recovery

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

87 (139)

MENU

WCDMA BTS CN-id: WN60082

Title: Base Station Operation Degraded - FSPC System module failure

Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Alarm - 7651 Base Station Operation Degraded - System module failure due to fault in FSPC. Root cause: Wrong function called in EDpdchSetReconfig command. Correction: Correct function called. Corrected Fault Reports: NA04713042 Base Station Operation Degraded - FSPC 01 System module failure Modified components: Component W1FingerDespreader.pcs Version wn60mp1_19#19.3

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Nokia Siemens Networks

Company Confidential

88 (139)

MENU

Customer Impact: Capacity & Performance: Decreased capacity, BTS restart needed for the recovery.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

89 (139)

MENU

WCDMA BTS CN-id: WN60083

Title: Hanging users in BTS causing RRC setup failures due to BTS. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: Hanging users in BTS causing RRC setup failures due to BTS. Root cause: Problem in TCOM SW. User transfer between the DSPs was started even the user deletion process was ongoing resulting the hanging users in DSPs Correction: DSP change will be rejected by Telecom SW in case when user deletion is ongoing. Corrected Fault Reports: NA0471928 No answer on EDCH (HSUPA Uplink) 62157ESPE04 Hanging resources in WSPC Modified components: Component 3grlcontroller.spr Version 3674

Change effects: Effects on end-user Effects on Operator Other effects


Nokia Siemens Networks Company Confidential

90 (139)

MENU

New functionality

Customer Impact: Capacity & Performance: RRC setup failures due to BTS. WSP/FSP restart needed for the recovery.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

91 (139)

MENU

WCDMA BTS CN-id: WN60084

Title: RF module failure with the combination of Flexi Rel1 RF module and Flexi Rel2 system module. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: RF module failure alarm seen with the combination of Flexi Rel1 RF module and Flexi Rel2 system module. Problem happens because the system module outputs too much power to the RF module. Root cause: Problem in Flexi Rel2 system module DSP SW. It is identified that for a certain user state transition (RL reconfiguration prepare for two RLs followed by the deletion for one RL) the gain limits were not updated. Subsequent power-up commands caused power to increase without limits. Rel1 RF module is not able to tolerate too high gain commands causing the RF unit spontaneous restart. Correction: The limitation of the maximum power gain added to DSP SW Corrected Fault Reports: NA04656716 Several sites that were installed in the FSME module; it are alarming daily (RF module). Modified components: Component Txcr.pcs Version wn60fb#18.12.9-2

Change effects: Effects on end-user

Nokia Siemens Networks

Company Confidential

92 (139)

MENU

Effects on Operator Other effects

New functionality None

Customer Impact: Capacity & Performance: Cell availability, temporary service break and dropped calls due to spontaneous RF module restart.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

93 (139)

MENU

WCDMA BTS CN-id: WN60085

Title: HSDPA CONFIGURATION FAILURE alarm. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: HSDPA CONFIGURATION FAILURE alarm. Root cause: Telecom SW does not always receive the response messages from the RF module. This was caused by the incorrect message response mode used in RF module SW. Correction: Message response mode changed to the correct one in RF module SW. Corrected Fault Reports: PR NA04600792 HSDPA CONFIGURATION FAILURE ALARM NA04695960 Operational HS-DSCH state in RNW issue NA04693124 HSDPA RECONFIGURATION FAILED Modified components: Component CAntennaCarrierAPI.cpp CRFRelatedSWManager.cpp CRFRelatedSWManager.hpp CUDPCPPort.cpp CUDPCPPortServer.cpp Version
1.0.7 1.0.4 1.0.2 1.0.1 1.0.4

Nokia Siemens Networks

Company Confidential

94 (139)

MENU

Change effects: Effects on end-user Effects on Operator Other effects

New functionality None Customer Impact: Capacity & Performance: No HSDPA service available. 7772 HSDPA CONFIGURATION FAILED alarm is active. BTS restart needed for recovery.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

95 (139)

MENU

WCDMA BTS CN-id: WN60086

Title: 100% HSUPA access failure rate Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: 100% HSUPA access failure rate Root cause: Problem in Telecom GRM (Global resource Manager). GRM mistakenly set the HSUPA pre-reservation to Rel1 while HSUPA for particular LCG was on recovery list and waiting to be recovered to Rel2. After Rel2 recovery action, HSUPA was allocated to master FSMB module although extension FSMD/E available Correction: HSUPA allocated to extension module when its available. Corrected Fault Reports: NA04723768 100% HSUPA access failure rate Modified components: Component HsupaCapacityPreReserving.spd full.itex full_flexi.cfg Version 4129 4129 4129

Change effects: Effects on end-user Effects on Operator Other effects


Nokia Siemens Networks Company Confidential

96 (139)

MENU

New functionality None Customer Impact: Capacity & Performance: HSUPA call not possible. BTS restart needed for the recovery

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

97 (139)

MENU

WCDMA BTS CN-id: WN60087

Title: FSPA autonomous recovery fails causing missing available CE's Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: FSPA autonomous recovery fails causing missing available CE's. Root cause: Problem in O&M SW. FSPA start-up fails occasionally after the unit recovery reset because the 'FSP exist' state was changed too early to true. Correction: FSP state handling corrected in recovery situations. Corrected Fault Reports: NA04704448 48 CE missing from FSMB NA04704678 418 to FSPA but hasn't recovered from this for some reason NA04727583 HSUPA failing in single system module site Modified components: Component SM_RESET_Pkg.sbs FSP_Agent.sbs FSPB_Agent.sbs FlexiFDrules.txt Version f_lt_td_19#0.5 f_19#0.7 f_19#0.18 f_19#0.26

Change effects:
Nokia Siemens Networks Company Confidential

98 (139)

MENU

Effects on end-user Effects on Operator Other effects

New functionality None Customer Impact: Capacity & Performance, degraded capacity.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

99 (139)

MENU

WCDMA BTS CN-id: WN60088

Title: Hanging users in BTS causing call setup failures due to BTS and DSP unit restarts. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: Hanging users in BTS causing call setup failures due to BTS and DSP unit restarts. Root cause: Problem in hanging user supervision functionality. TCOM does not start the hanging user deletion mechanism is user if the user is not found from Telecom database. Due to this problem DSP is set temporarily to hold state and eventually the DSP unit is restarted. Correction: Hanging user supervision functionality corrected to delete the detected hanging users without further actions. Corrected Fault Reports: Modified components: Component sctenv.c sdl2h_newLRM.h sdl2h_newLRM.c h2sdl_newLRM.h h2sdl_newLRM.c Version 4314 4314 4314 4314 4314

Change effects: Effects on end-user


Nokia Siemens Networks Company Confidential

100 (139)

MENU

Effects on Operator Other effects

New functionality None Customer Impact: Capacity & Performance: RRC setup failures due to BTS. Temporary capacity degradation and dropped calls due to DSP unit autonomous restart. HSUPA establishment failure due to lack of HW capacity in especially certain UltraSite configurations as the CCHs and HSDPA are HSDPA are moved to same WSPC unit after the WSP unit autonomous restart.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

101 (139)

MENU

WCDMA BTS CN-id: WN60089

Title: WSPC Unit SW download failed Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: WSPC Unit SW download fails after the unit recovery. Root cause: Root cause: Missed message acknowledgement during the DSP SW DL procedure. When this failure happens O&M will re-start the whole SW DL procedure but based on the logs same problem happens again but with the different moment of the SW DL procedure. If two 2 re-attempts fail the SW DL failure alarm is activated. Correction: Correction purpose is to reduce the risk of failure during re-transmission. In this SW the failed SW package is identified and only the failed package is re-transmitted. If acknowledgement is still missing after 5 re-attempts, then the complete SW package is transmitted. Corrected Fault Reports: NA04589528: WSP Unit SW download failed Modified components: Component Version

Change effects: Effects on end-user Effects on Operator Other effects

Nokia Siemens Networks

Company Confidential

102 (139)

MENU

New functionality None

Customer Impact: Capacity & Performance: WSPC unit not in service causing the capacity degradation. BTS restart needed for the recovery.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

103 (139)

MENU

WCDMA BTS CN-id: WN60090

Title: Flexi Rel2 extension module restart after 2 weeks in operational state Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Flexi Rel2 extension module restart after 2 weeks in operational state. Root cause: Due to the coding bug the memory release for certain polling task in HW related SW fails. Due to this fault memory consumption increases periodically and after 2 week in runs out causing the Flexi rel2 extension system module restart. Correction: Memory release corrected. Corrected Fault Reports: NA04720900 NodeB About problem of BBU NA04704534 FSME is lost NA04724030 Alarm 7651 Failure in optical RP3 interface still present in PP0.04 BTS SW Modified components: Component WCDMA_HWR_PR_CD_2013 Version -

Change effects: Effects on end-user

Nokia Siemens Networks

Company Confidential

104 (139)

MENU

Effects on Operator Other effects New functionality None

Customer Impact: Capacity & Performance: Cell availability, temporary service break and dropped calls due to spontaneous Flexi Rel2 extension module restart.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

105 (139)

MENU

WCDMA BTS CN-id: WN60091

Title: HSDPA Congestion Control related problems with narrow Iub bandwidth. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: HSDPA Congestion Control related problems with narrow Iub bandwidth Root cause: Problem1: When congestion is detected on Iub, congestion control does not allocate credits for inactive users. Because of averaging/rounding in SW, sometimes low data rate users on a narrow Iub case may end up being determined as inactive even if there were PDU arrivals recently. Problem2: Secondly, the calculated credits were not updated to users unless they were selected for credit reduction. Corrections: Correction1: After the correction the user is considered active if it has had data waiting to be transmitted in RNC user buffer during last 80ms. Correction2: After the correction: the calculated credits are updated without credit reduction multiplier in case they were not selected for credit reduction.

Corrected Fault Reports: 65148ESPE02 WBTS WN5.0: HSDPA Congestion Control related problems with narrow Iub bandwidth

Modified components: Component


Nokia Siemens Networks Company Confidential

Version
106 (139)

MENU

SC_TUP

r1383

Change effects: Effects on end-user

Effects on Operator

Other effects

New functionality

Customer Impact: Capacity & Performance: HSDPA Congestion control does not work as expected, potential performance degradation with narrow band Iub. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results: -

Nokia Siemens Networks

Company Confidential

107 (139)

MENU

WCDMA BTS CN-id: WN60092

Title: BTS allocates HSDPA credits too aggressively on narrow Iub bandwidth causing rapid increase in A2SP data queue. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: BTS allocates HSDPA credits too aggressively on narrow Iub bandwidth causing rapid increase in A2SP data queue. Root cause: SW bug in TUP SW negated the effect of a credit calculation ramp-up term which should limit the amount of credits (MAC-d PDUs) per user to increase according to amount of MAC-d PDUs received from the Iub interface. Correction: After the correction the maximum credits per user can be up to 2 * received_PDUs + 10. This is rather aggressive ramp-up which adapts to different Iub capacities. In order to keep a good performance with interactive traffic and in beginning of the connection, in case of short gaps in the data transmission, this term does not immediately revert to initial value (10) but is slowly decreased during gaps. Corrected Fault Reports: 65149ESPE02 WBTS WN5.0: BTS allocates HSDPA credits too aggressively on narrow Iub bandwidth causing rapid increase in A2SP data queue NA04654502 Elevated KPIs past PCD1.34 installation. HSDPA Drops increased. NA04696865 MNRNC01: Intermitently R99 PS NRT Call Failure

Modified components: Component


Nokia Siemens Networks Company Confidential

Version
108 (139)

MENU

SC_TUP

r1383

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Customer Impact: Capacity & Performance: Call KPI degradation Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

109 (139)

MENU

WCDMA BTS CN-id: WN60093

Title: Can not open snapshot with BTS Site Manager version WN60-6.1.92 Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: Can not open snapshot with BTS Site Manager version WN60-6.1.92 Root cause: Snapshot file handling problem in BTS Site Manager Correction: Snapshot file handling problem corrected. Corrected Fault Reports: 40499ESPE03 Can not open snapshot if SEM version BTSSiteEM-WN60-6.1.92 is installed to PC Modified components: Component cl.jar Version 4.0.40

Change effects: Effects on end-user Effects on Operator Other effects New functionality

Nokia Siemens Networks

Company Confidential

110 (139)

MENU

Customer Impact: Operation & Maintenance: Can not open snapshot with BTS Site Manager version WN606.1.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

111 (139)

MENU

WCDMA BTS CN-id: WN60094

Title: Improvement related to RAN1638: Flexible RLC (DL): Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Improvement related to RAN1638: Flexible RLC (DL): Root cause / Change: RAN1638: Flexible RLC (DL): The flow control with HS-DSCH Capacity Allocation Type 2 is upgraded to be capable of signaling any data rate accurately to RNC. Previously the accuracy was a multiplication of 1 MAC-d PDU, which is expected to be non-optimal for large PDU sizes on cell edge or in narrow Iub conditions. Corrected Fault Reports: Modified components: Component TUP SW Version WN6.0 12.4-172_A

Change effects: Effects on end-user Effects on Operator Other effects

New functionality

Nokia Siemens Networks

Company Confidential

112 (139)

MENU

Customer Impact: Capacity & performance: Less drop calls in the cell edge or in narrow Iub conditions when Flexible RLC feature is enabled.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

113 (139)

MENU

WCDMA BTS CN-id: WN60095

Title: The HSDPA Congestion Control improvements in the WN6.0 MP1 for WSPF, FSMC/D/E Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References:

Reason for the Change Note: Change reason: HSDPA congestion control is not working in optimum way. Change description: See attachment

The HSDPA Congestion Control ch

Corrected Fault Reports: Modified components: Component TUP SW Version WN6.0 12.4-172_A

Change effects: Effects on end-user Effects on Operator Other effects

New functionality
Nokia Siemens Networks Company Confidential

114 (139)

MENU

Yes Customer Impact: Capacity & Performance: HSDPA congestion control is not working in optimum

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

115 (139)

MENU

WCDMA BTS CN-id: WN60096

Title: Data base conversion problem eliminating the decimals from the feeder loss. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: DB conversion from WN5.0 to WN6.0 is eliminating decimal figures of feeder loss parameter, i.e., if the right feeder loss is -2.8 in WN5.0 DB and you open it with RU20 WBTS Site Manager, which converts the value, the decimal figure is missing and the feeder loss parameter value is -2.0 Root cause: DB conversion problem in BTS Site Manager. Correction: DB conversion problem corrected Corrected Fault Reports: NA04726434: DB conversion from WN5.0 to WN6.0 it's eliminating decimal figures of feeder loss parameter. Modified components: Component common.jar Version WN6.0 19. 5-173_A

Change effects: Effects on end-user Effects on Operator Other effects

Nokia Siemens Networks

Company Confidential

116 (139)

MENU

New functionality Customer Impact: Capacity & Performance: Possible KPI degradation due to incorrect feeder loss value.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

117 (139)

MENU

WCDMA BTS CN-id: WN60097

Title: Reduced HSDPA throughput when Congestion Control feature is enabled with RU20. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: Reduced HSDPA throughput when Congestion Control feature is enabled with RU20. Root cause: Problem in the BTS delay calculation functionality resulting the positive bias in the delay calculations. Overtime as the delay accumulated it eventually crossed the delay threshold and Congestion Control recognized that as a congestion situation and reduced the throughput. Correction: Delay compensation mechanism is being implemented to TUP SW to prevent the positive bias in the delay calculations. Corrected Fault Reports: NA04711547 M5000C100_ORIG_TRANS_10_CODE_16QAM decreased after BTS SW upgrading from WN5.0 to WN6.0 NA04713568 Flexi reporting TNL congestion after 30min DL FTP: Single UE, STM-1 Iub Modified components: Component TUP SW Version -

Change effects: Effects on end-user


Nokia Siemens Networks Company Confidential

118 (139)

MENU

Effects on Operator Other effects New functionality Customer Impact: Capacity & Performance: Reduced HSDPA throughput when Congestion Control feature is enabled with RU20.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

119 (139)

MENU

WCDMA BTS CN-id: WN60098

Title: Common transport channel setup fails after the long Iub link break. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Problem with common transport channel setup after the long Iub link break. Root cause: Coding error in TUP connection manager. Transport channel reset procedure does not work after the Iub link break detection, which leads to spontaneous BTS reset. Correction: Coding error in TUP connection manager fixed. Note! This problem exists only in newest WN6.0 MP1 pilot SWs. Fault does not exists in WN6.0 MP1 (WN6.0 19.5-179) or previous BTS SWs Corrected Fault Reports: PR 64106ESPE04: Common transport channel setup fails after extension module recovery, cells goes down. NA04731458 Site re-starts during Dual Iub T1 test case. Modified components: Component TUP_SC Version r1744

Change effects: Effects on end-user Effects on Operator


Nokia Siemens Networks Company Confidential

120 (139)

MENU

Other effects New functionality Customer Impact: Capacity & Performance: Cell availability, Common transport channel setup fails after the extension module recovery.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

121 (139)

MENU

WCDMA BTS CN-id: WN60099

Title: FTM Plan Upload Validation Fails in NetAct Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: FTM Plan Upload Validation Fails in NetAct Root cause: In RAS06 release, FTMs ATM Traffic Descriptor (TRDE) objects were allowed to be created with identifiers in the range of 100-999999999. In RU10 this range was changed to 100-131. On Upgrade to RU10, FTM plan files uploaded from such WBTS using Traffic Descriptors with identifiers greater than 131 were failed during validation at NetAct. Correction: This has been corrected by changing the range back to previously allowed range of 100-999999999. Corrected Fault Reports: NA04711080 OSS does not allow WBTS/FTM Traffic Descriptor Pointer larger than 131 which is imcompatible with existing WBTS configuration Modified components: Component FTM SW Version FTM_A60_MP1_181.00

Change effects: Effects on end-user Effects on Operator

Nokia Siemens Networks

Company Confidential

122 (139)

MENU

Other effects New functionality

Customer Impact: Operability & Maintenance: Plan upload fails.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

123 (139)

MENU

WCDMA BTS CN-id: WN60100

Title: EUBB: WAM unit faulty state without alarms after WAM block/unblock. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: Secondary WAM unit faulty state without alarms after secondary WAM block/unblock. Root cause: Problem BTS O&M alarm handler. Correction: Alarm handling corrected. Corrected Fault Reports: NA04705049 EUBB: Wrong WAMA behaviour after block/unblock: faulty state without any alarms Modified components: Component EUBBFDrules.txt Version eu_19#0.31

Change effects: Effects on end-user Effects on Operator Other effects New functionality

Nokia Siemens Networks

Company Confidential

124 (139)

MENU

Customer Impact: Capacity & Performance: Secondary WAM unit faulty state without alarms after secondary WAM block/unblock, no calls possible. BTS reset needed for recovery.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

125 (139)

MENU

WCDMA BTS CN-id: WN60101

Title: Telecom configuration failure with the FRKA module Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Telecom configuration failure with the FRKA module. Root cause: FRKA registers are initialised incorrectly. Correction: FRKA register initialization corrected. Corrected Fault Reports: NA04721072 Telecom configuration failure by the specific FRKA module Modified components: Component FRM Version 02.07.R05

Change effects: Effects on end-user Effects on Operator Other effects New functionality

Nokia Siemens Networks

Company Confidential

126 (139)

MENU

Customer Impact: Capacity & Performance: Cells out of use, Telecom Configuration Failure alarm active.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

127 (139)

MENU

WCDMA BTS CN-id: WN60102

Title: Antenna Line Device failure alarm not cleared. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: Antenna Line Device failure alarm not cleared Root cause: Problem in BTS O&M SW. Incorrect unit name send in Antenna Line Device failure alarm cancel message. Correction: Unit name corrected. Corrected Fault Reports: NA04713226 BTS Needs reset after Antenna Line Device failure alarm is cleared. Modified components: Component FORE_FDAR_Pkg.sbs Version f_lt_19#0.6

Change effects: Effects on end-user Effects on Operator Other effects New functionality
Nokia Siemens Networks Company Confidential

128 (139)

MENU

Customer Impact: Operability: Unnecessary alarm, BTS reset needed to clear the alarm. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

129 (139)

MENU

WCDMA BTS CN-id: WN60103

Title: RET device detection fails. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: RET device (manufactured by Tongyu) detection fails with WN6.0 MP0 Root cause: Improper handling of unexpected HDLC message in BTS O&M antenna line management function. Correction: Handling of the unexpected HDLC messages corrected. Corrected Fault Reports: NA04713320 RET device (manufactured by Tongyu) can not be detected on WN6.0MP0 Modified components: Component ALMAG_CC_Pkg.sbs Version f_lt_19#0.13

Change effects: Effects on end-user Effects on Operator Other effects New functionality
Nokia Siemens Networks Company Confidential

130 (139)

MENU

Customer Impact: Operability: RET device not detected, RET angles can not be changed.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

131 (139)

MENU

WCDMA BTS CN-id: WN60104

Title: MHA or RET device alarm timing issue. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station References:

Reason for the Change Note: Problem: MHA or RET device alarm takes the NodeB up to 5 minutes to activate the alarm. However, RET devices disappears from RET device management window earlier. Root cause: Timer problem in BTS O&M alarm handling. Correction: Timer problem corrected Corrected Fault Reports: NA04701543 RU20 Pilot; TMOUS; MHA and RET alarm timing issue Modified components: Component FlexiFDrules Version f_19#0.26

Change effects: Effects on end-user Effects on Operator Other effects

Nokia Siemens Networks

Company Confidential

132 (139)

MENU

New functionality

Customer Impact: Operability: Incorrect RET status visible for a while. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

133 (139)

MENU

WCDMA BTS CN-id: WN60105

Title: No answer on EDCH (HSUPA Uplink) Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: Hanging HSUPA resources. Root cause: Telecom and HSUPA L2 have different understanding about HSUPA resources. Correction: HSUPA resource allocation corrected. Corrected Fault Reports: NA04719281 No answer on EDCH (HSUPA Uplink), HSUPA L2 Modified components: Component ResSelRl.cpp CodecDspRmHsupaL2.pcs Version 4461 Wn60c_MP1#19.5-176

Change effects: Effects on end-user Effects on Operator


Nokia Siemens Networks Company Confidential

134 (139)

MENU

Other effects New functionality

Customer Impact: Capacity & Performance: Decreased HSUPA capacity, HSUPA call drops.

Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

135 (139)

MENU

WCDMA BTS CN-id: WN60106

Title: WBTS does not get On Air after upgrade from WN5.0. Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): Flexi WCDMA Base Station UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: WBTS does not get On Air after upgrade from WN5.0 Root cause: New commissioning file version generation causes high CPU load causing TUP not getting enough runtime, which slows down the handling of the configuration file. Due to this reason O&M resends the HW configuration message to TUP but it will be rejected as the first message is already under handling. This causes O&M to raise alarm and cells stay down. Correction: TUP will not reject the second message when first one is already under handling. Corrected Fault Reports: NA04729154 Cnbap is down after activation WN6.0 MP0 Modified components: Component FSPC-TUP Version T0001809.BIN

Change effects:
Nokia Siemens Networks Company Confidential

136 (139)

MENU

Effects on end-user Effects on Operator Other effects New functionality Customer Impact: Capacity & Performance: Cell availability decreased. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

137 (139)

MENU

WCDMA BTS CN-id: WN60107

Title: File sending failed" pop up on sitemgr when commission Version of the SW-build: WN6.0 MP1 (WN6.0 19.5-179) Valid for Product(s): UltraSite WCDMA Base Station References:

Reason for the Change Note: Problem: "File sending failed" pop-up window on BTS Site Manager view after the UltraSite BTS the recommissioning (recommission, template commission). Despite the pop-up window information the commissioning file is downloaded and activated with the new parameters to the BTS. Root cause: BTS Site Manager compilation fault. Interface mismatch between two BTS Site Manager subcomponents. Correction: Interface problem corrected in BTS Site Manager compilation phase. Corrected Fault Reports: 49958ESPE01 File sending failed" pop up on sitemgr when commission Modified components: Component UltraBTSManager Version 6.1.65

Change effects: Effects on end-user Effects on Operator


Nokia Siemens Networks Company Confidential

138 (139)

MENU

Other effects New functionality

Customer Impact: Operability: Unnecessary File sending failed pop-up window visible on BTS Site Manager view after the UltraSite BTS the recommissioning. Testing Instructions for the change Pre-requirements:

Test execution: This correction cannot be tested using the operator interface commands. The correction is tested internally in Nokia Siemens Networks test lab and proved to be fully functional

Expected results: Unexpected results:

Nokia Siemens Networks

Company Confidential

139 (139)