Wastewater Management Range

retro
Modulus

Septic Upgrade Systems

Flows & Loads


Per person / activity / day (unless otherwise specified)

FLOW
(Litres)

BOD
(Grams)

Ammonia as N
(grams)

Domestic Dwellings
The table of Loadings detailed opposite was prepared by the British Water Package Sewage Treatment Plant Focus Group comprising all major manufacturers, suppliers and service companies of all types of small waste water treatment systems. The Environment Agency, the Northern Ireland Environment Agency and the Scottish Environment Protection Agency support the use of this code of practice. This table of loadings allows the total daily sewage load from properties to be calculated and it is recommended that all manufacturers and designers should use this table when sizing and designing non-mains sewage treatment systems. The flows and loads values given represent current best knowledge within the UK but may change with time in line with per capita water use. The user/purchaser should be made aware that there is a risk of poor performance from the equipment if loads are understated. The accuracy of the declared loads is of paramount importance. expected total load and the flow, considering both peak and total flow. Guidance is provided to assist the user to identify the various sources of sewage, to consider the nature of the sewage to be treated and to make users aware of issues which may affect treat ability and system performance. The table of loadings may be used to design all sizes of sewage treatment systems serving up to 1000 population.
Standard residential Mobile home type caravans with full services 180 180 60 75 8 8

Industrial
Office / Factory without canteen Office / Factory with canteen Open industrial site, e.g. construction, quarry, without canteen *Full-time Day Staff *Part-time Staff (4 hr shift)

Index
90 50 200 90 38 25 75 38 300 250 80 350 60 227 30 25 15 15 12 12 100 105 94 50 150 25 94 38 30 19 19 12 15 56

50 100 60 90 45

25 38 25 38 25

5 5 5 5 3

Schools
Non-residential with canteen cooking on site Non-residential without a canteen Boarding school (i) residents (ii) day staff (inc. mid-day meal) 5 5 10 5

Hotels, Public Houses & Social Clubs


Hotel Guests (Prestige hotels) Hotel Guests (3H & 4H hotels) Guests (Bedroom only no meals) Residential Training/Conference Guest (inclusive all meals) Non residential Conference Guest Drinkers 12 15 5 Holiday camp chalet resident Resident Staff 180 75 10 Restaurants - Full Meals - luxury catering - pre-prepared catering - Snack Bars & bar meals - Function Rooms including buffets - Fast Food i.e. (roadside restaurants) - Fast Food Meal (burger chain and similar) Students (Accommodation only) 12 10 6 15 2.5 10 4 2.5 2.5 2.5 2.5 4 5

Amenity Sites
Toilet Blocks (per use) Toilet (WC) (per use) Toilet (Urinal) (per use) Toilet Blocks in long stay car parks/lorry parks (per use) Shower (per use) Golf Club Local community sports club, e.g. squash, rugby & football Swimming ( A separate pool without an associated sports centre) Health Club/Sports Centre Tent sites Caravan Sites : i) Touring not serviced (ii) Static not serviced (iii) Static fully serviced 10 10 5 10 40 20 40 10 50 75 100 100 180 12 12 12 19 19 19 25 12 19 44 44 44 75 2.5 2.5 2.5 4 2 5 6 2.5 4 8 8 8 8

Hospitals & Residential Care Homes


Residential old people / nursing Small hospitals Large hospitals *Staff figures also apply to other applications 350 450 110 140 Assess individually 13 Assess

rangespecification
OR1 plant shown below

i H

RETRO
Model

Population Equivalent

Minimum Septic Tank volume required

Hydraulic Flow Litres per day

BOD Loading Grams per day

Overall Height H

Width

Length

Inlet Invert

OR1 OR2 OR3

6 12 20

2700 4500 6000

1080 2160 3600

360 720 1200

1535 1920 2135

1260 1260 1260

2770 2770 2770

500 500 500

Please Note : Larger Retro Systems can be designed and supplied on request. *Hydraulic flows and BOD loading are based upon British Waters Flows & Loads criteria for domestic applications detailed on previous page. All systems must have a fully functional septic tank upstream with an unrestricetd influent from the tank. This is imperative in the performance of this system.

All dimensions in millimetres unless otherwise stated. Oaklands reserve the right to change specification without prior notice in line with our policy of continuous development

www. oaklandsenvironmental.com

e n v i r o n m e n t a l
Sales Office East Way Rivergreen Industrial Park Pallion Industrial Estate Sunderland SR4 6AD T. +44 (0)191 415 9090 F. +44 (0)191 565 2946 E. sales@oaklandsenvironmental.com

aklands
Accounts Station Road Coleshill Birmingham B46 1HT T. +44 (0)1675 466 321 F. +44 (0)1675 462 395 E. accounts@oaklandsenvironmental.com

PART OF THE OAKLANDS GROUP OF COMPANIES

www.oaklandsplastics.com

Potrebbero piacerti anche