General

Electromagnetic Flow Meter


MagFlux Electromagnetic Flow Meters deliver very stable and highly accurate ow measurements in conductive liquids. MagFlux Flow Meters have no moving parts to foul, create no hydraulic inuence on the ow, use a well-proven technology, and communicate using a standard protocol. MagFlux Flow Sensors are available in sizes ranging from DN 3 to DN 1200, with standard construction lengths and connections. MagFlux Flow Meters can be installed either with the electronics mounted on the ow sensor, on a wall, or mounted in a panel.

Applications

MagFlux Flow Meters are used for measuring and totalizing ow of conductive liquids in pressurized closed pipe systems. The MagFlux operation is based on Faradays law of induction. When a conductive uid passes through a magnetic eld in the sensor, an electromagnetic voltage is induced between the two electrodes in the ow sensor tube. This voltage (E) is directly proportional to the uid velocity.

MagFlux Flow Meters measure ow in both directions of potable water, wastewater and process uids. When the internal diameter of the Flow Sensor is known, the actual volume is calculated by the Converter. The electromagnetic voltage induced between the electrodes equates to: E = L x B x V where:
E: L: B: V: Induced electromagnetic voltage Flow sensor diameter The strength of the magnetic eld The velocity of the liquid

Function

The voltage E is measured and consequently converted to a volumetric ow. Flexible Installation MJK's modular design is versatile. The Display Unit can be mounted up to 1000 m from the Flow Converter with ordinary twisted wires. It also provides options for mounting the Converter where it is most convenient to make the electrical connections.
The MagFlux Converter and Display Unit mounted directly on the Flow Sensor.

One Display Unit can control up to 4 Converters and Flow Sensors for greater economy, space savings and an improved overview of the multiple measurement values.

The MagFlux Converter mounted directly on the ow sensor with a remote mounted Display Unit.
In noisy environments, twisted shielded cable is recommended.

Max. 1.000 m twisted cable

The MagFlux Converter and Display Unit remote mounted. For example when the sensor is being buried or submerged. The MagFlux Converter is mounted remote from the Flow Sensor, and the Display Unit is mounted separately from the Converter. E.g when the Sensor is being buried.

Max. 50 m spec. cable

Max. 50 m spec. cable

Max. 1.000 m twisted cable

Max. 1.000 m twisted cable (total) The MagFlux Converters are mounted directly on the Flow Sensors, while the remote mounted Display Unit communicates with two MagFlux Converters and Flow Sensors.

GB 3.05 MagFlux 071116

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Data Sheet
Simple to Operate

Electromagnetic Flow Meter


The MagFlux Display Unit has many unique and intelligent functions. It has a simple mobile phone-like menu structure and can display text in several selectable languages in metric or English units. The MagFlux PC connection allows downloading congurations and logging data to a PC, and uploading new software updates and instrument customization. All through intuitive steps using a common USB port. The MagFlux System registers the Flow Sensor to the Converter using a unique coded six-digit serial number technique. It sets calibration data, the nominal diameter and the sensor conguration making the MagFlux System ready to measure immediately. This avoids complicated and sensitive eld calibration and delicate electronics in the sensor, and allows unlimited interchanging of MagFlux Converters and Flow Sensors. The MagFlux Converter has resettable and non-resettable counters for ow in both directions. MagFlux has two batch counters with smart-batch counting. The MagFlux System measures ow in both directions and can totalize the net ow for both. A simple menu selection determines the normal ow direction. The MagFlux built-in 256 kB data logger can log 20.000 entries with time and date. Data is displayed graphically, but can also be exported to a PC via the USB port on the Display Unit. The MagFlux Converter has one 4-20 mA analogue output, two digital outputs and one digital input. The digital input can stop and zero counter settings or control the batch counters manually. Each alarm can be displayed as a pop-up alarm until they are reset. The MagFlux built-in electronic electrode cleaning system is always active. The MagFlux display can be congured by the user for up to ve lines of text. The graphic display is automatically adjusted to show the largest characters possible. The Display Unit uses the Modbus communication protocol to connect to the MagFlux Converter or a PLC.

Easy-to-use Menu Structure

Registering the Flow Sensor

Counters for Flow in Both Directions

Forward and Backwards Flow Measurement and Totalizing

Data Logger

Flexible In- and Outputs

Automatic Electrode Cleaning User Denable Text

Modbus Communication

GB 3.05 MagFlux 071116

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Data Sheet
Specications
Converter and Display Unit
Display unit Enclosure rating Housing material Protection lid Display Indication Clock Communication Interface Memory Interface Temperature range Converter Accuracy Measuring range Min. liquid conductivity Analog output Digital outputs

Electromagnetic Flow Meter

Dust- and waterproof IP 67, NEMA 6 (when mounted on Converter) Polycarbonate, glass reinforced Transparent polycarbonate White backlit LCD-display (64 x 128 pixels) with softkeys Indication of ow, ow direction, volume, totalizers, conguration and graph Real-time clock with built-in battery backup MODBUS RTU-mode, 9600 baud, 2-wire RS 485, master-mode RS 485 256 Kb Flash Memory, 20.000 entries with date, time and value USB 1,1 type mini B, Female - 20 60 C

+/- 0,1% of reading Min. range = 0 - 0,2 m/s Max. range = 0 - 10 m/s 5 mS One active 4 - 20 mA, galvanically isolated (max. load 800 ) One voltage-free electromechanical relay (max. 50 V DC / 1 A) One optically isolated MOSFET relay (max. 50 VAC / V DC / 120 mA) programmable for: totalizer counter, batch counter, high/low ow, system error, empty pipe and ow direction. One, max. 30 V DC, < 5 V DC = 0 (low), > 10 V DC = 1 (high), pulse length > 100 ms MODBUS RTU-mode, 9600 baud, 2-wire RS 485, slave-mode RS 485 for connection to Display Unit or PLC 24 V AC, 50 / 60 Hz 10 % or 115 V AC, 50 / 60 Hz 10 % or 230 V AC, 50 / 60 Hz 10 % Power consumption max. 10 W Polycarbonate, glass reinforced IP 67, NEMA 6 - 20 60 C 1,0 kg EN 61000-6-4:2001, EN 61000-6-2:2001

Digital inputs Communication: Interface Power supply

Cabinet material Enclosure rating Temperature range Weight CE approvals Connection box Enclosure rating Cabinet material Temperature range

IP 68, NEMA 6X (using gel potting kit part no. 579035). The owmeter can withstand unlimited immersion of up to 10 m of water. Polycarbonate, glass reinforced - 20 100 C

Mechanical Dimensions,
Converter and Display Unit

162 156

186 89 83

183 85 79

150 144

M20

GB 3.05 MagFlux 071116

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Data Sheet
IP 68 Protection

Electromagnetic Flow Meter


If the MagFlux Sensor is to be buried or submerged under water, the Converter and Display Unit must be remote mounted, and the electrical connection to the sensor must be potted using gel potting kit part no. 579035.

Order Numbers
MagFlux Converters, Displays and Accessories

MagFlux converter 207910 207911 207912 207920 207921 207922 207925 207926 MagFlux Converter (blind) for sensor mounting 230 V AC Optional 115 V AC MagFlux Converter (blind) for sensor mounting 24 V AC MagFlux Converter (blind) 10 - 30 V DC MagFlux Converter with Display Unit for Flow Sensor mounting 230 V AC Optional 115 V AC MagFlux Converter with Display Unit for Flow Sensor mounting 24 V AC MagFlux Converter with Display Unit 10 - 30 V DC MagFlux Converter with Display Unit for wall mounting 230 V AC Optional 115 V AC MagFlux Converter with Display Unit for wall mounting 24 V AC

Accessories 207930 207935 207937 207940 579035 691080 691095 840110 MagFlux Wall Mounting Kit MagFlux Panel Mounting Bracket MagFlux Lightning Protection Kit MagFlux Display Unit MagFlux Gel Potting Kit MagFlux Sensor Cable MagFlux USB Cable MJK-Field Link software for communication between MagFlux and PC

207920, MagFlux Converter with Display Unit for Sensor Mounting

207930, MagFlux Wall Mounting Kit

207935, MagFlux Panel Mounting Bracket

MagFlux mounted in a panel

Electromechanical relay max. 50 V AC / 1 A

Electronic relay max. 50 V DC 120 mA

DO 1

DO 2

DI 1

4-20 mA output

Digital output 2

Digital output 1

Power supply

For attached Display Unit

For remote Display Unit

Digital input 10-30 V DC

GB 3.05 MagFlux 071116

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Fuse rating: 100 mAT @ 115 V AC 63 mAT @ 230 V AC

Connection for Flow Sensor

4-20 mA max. 800

Brown

Electrical Connections on the Converter


White Black Blue Red

Data Sheet
Example 1
Compact Converter and Display Unit on Flow Sensor

Electromagnetic Flow Meter

Order numbers 207xxx MagFlux Flow Sensor 207920 MagFlux Converter with Display Unit, 230/115 V AC

Example 2
Remote Converter, Connection Box on Flow Sensor

If the MagFlux Sensor is to be buried or submerged under water, the Converter and Display Unit must be remote mounted, and the electrical connection to the Flow Sensor must be potted using Gel Potting Kit part no. 579035.

Converter and Display Unit in Wall / Panel Housing

MagFlux Sensor Cable Part No. 691080 (max. 50 m)

Order numbers 207xxx MagFlux Flow Sensor 207925 MagFlux Converter with Display Unit for wall mounting, 230/115 V AC

691080 MagFlux Sensor


Cable

577935 MagFlux Gel Potting


Kit IP68.

GB 3.05 MagFlux 071116

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Data Sheet
Example 3
Remote Display and Multiple Converter Wiring

Electromagnetic Flow Meter

The communication between the Display Unit is carried out on a 2-wire cable using ModBus communication on the RS-485 transmission lines.

2-wire cable (max.1000 m). Twisted shielded cable is recomended

Two additional wires supply power from one of the Converters to the Display Unit.

4-wire cable (max. 1000 m). Twisted shielded cable is recomended The Display Unit on wall mounting kit. The Display Unit can operate up to four Converters. Order numbers 2 pcs. 207xxx MagFlux
Flow Sensors

1 pc. 207910 MagFlux Converter (blind) for sensor mounting, 230/115 V AC 1 pc. 207925 MagFlux
Converter with Display Unit for wall mounting, 230/115 V AC

GB 3.05 MagFlux 071116

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Data Sheet
Flow Sensor 7100
Housing: Carbon steel Lining: PTFE

Electromagnetic Flow Meter

D Size

Sizes and Ordering information

Sizes and Ordering Information - EN Flanges Size DN 15 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 Pressure PN 40 40 40 40 40 16 16 16 16 16 16 16 10 10 10 10 D [mm] 95 105 115 140 150 165 185 200 220 250 285 340 395 445 505 565 L Weight [mm] [kg] 200 3,5 200 3,5 200 3,5 200 6 200 7 200 8 200 10 200 12 250 16 250 21 300 28 350 35 450 43 500 55 550 66 600 94 Order no. 207107 207110 207113 207116 207119 207122 207125 207128 207131 207134 207137 207140 207143 207146 207149 207152

Sizes and Ordering Information - ANSI Flanges Size Pressure D [inch] [psi] [mm] " 150 90 " 150 100 1" 150 110 1" 150 120 1" 150 130 2" 150 150 2" 150 180 3" 150 190 4" 150 230 5" 150 255 6" 150 280 8" 150 345 10" 150 405 12" 150 485 14" 150 535 16" 150 600 L Weight [mm] [kg] 200 3,5 200 3,5 200 3,5 200 6 200 7 200 8 200 10 200 12 250 16 250 21 300 28 350 35 450 43 500 55 550 66 600 94 Order no. 297107 297110 297113 297116 297119 297122 297125 297128 297131 297134 297137 297140 297143 297146 297149 297152

PN 25-40-64. Consult the factory.

300-600 psi. Consult the factory.

Specications

Specications - EN / ANSI Flanges Mounting Materials Housing Flanges Lining Electrodes Accuracy Media temp. range Ambient temp. range Compact converter Remote converter Enclosure Flange EN-1092-1 / ANSI B 16.5 Carbon steel Carbon steel PTFE 1,4571 / AISI 316 TI Better than 0,25 % -20150 C / 0300 F -1060 C / 15140 F -20100 C / 0200 F IP67, IP 68 / NEMA 4, NEMA 6P

Hastelloy C4, platinium, and titanium. Consult the factory. Of measured value. From DN 50 / 2 and up, a ground electrode is built in. Also avalible in Steel 304/316 SS. Consult the factory.

130/135

GB 3.05 MagFlux 071116

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Data Sheet
Flow Sensor 7200
Housing: Carbon steel Lining: Hard rubber

Electromagnetic Flow Meter

D Size

Sizes and Ordering information

Sizes and Ordering Information - EN Flanges Size DN 15 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 900 1000 1200 Pressure PN 40 40 40 40 40 16 16 16 16 16 16 16 10 10 10 10 10 10 10 10 6 6 6 6 D [mm] 95 105 115 140 150 165 185 200 220 250 285 340 395 445 505 565 615 670 780 895 1015 1115 1230 1450 L [mm] 200 200 200 200 200 200 200 200 250 250 300 350 450 500 550 600 600 600 600 700 800 900 1000 1200 Weight Order no. [kg] 3,5 207207 3,5 207210 3,5 207213 6 207216 7 207219 8 207222 10 207225 12 207228 16 207231 21 207234 28 207237 35 207240 43 207243 55 207246 66 207249 94 207252 105 207255 122 207258 158 207261 230 207264 325 207267 420 207270 510 207273 680 207276

Sizes and Ordering Information - ANSI Flanges Size [inch] " " 1" 1" 1" 2" 2" 3" 4" 5" 6" 8" 10" 12" 14" 16" 18 20 24 28 32 36 40 48 Pressure [psi] 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 D [mm] 90 100 110 120 130 150 180 190 230 255 280 345 405 485 535 600 635 700 815 930 1050 1170 1275 1510 L [mm] 200 200 200 200 200 200 200 200 250 250 300 350 450 500 550 600 600 600 600 600 800 800 800 1000 Weight [kg] 3,5 3,5 3,5 6 7 8 10 12 16 21 28 35 43 55 66 94 105 122 158 230 325 420 510 680 Order no. 297207 297210 297213 297216 297219 297222 297225 297228 297231 297234 297237 297240 297243 297246 297249 297252 297255 297258 297261 297264 297267 297270 297273 297276

PN 25-40-64. Consult the factory.

300-600 psi. Consult the factory.

Specications

Specications - EN / ANSI Flanges Mounting Materials Housing Flanges Lining Electrodes Accuracy Media temp. range Ambient temp. range Compact converter Remote converter Enclosure Flange EN-1092-1 / ANSI B 16.5 Carbon steel Carbon steel Hard rubber 1,4571 / AISI 316 TI Better than 0,25 % -1080 C / 15175 F -1060 C / 15140 F -1080 C / 15175 F IP67, IP68 / NEMA 4, NEMA 6P

Hastelloy C4, platinium, and titanium. Consult the factory. Of measured value. From DN 50 / 2 and up, a ground electrode is built in. Also avalible in Steel 304/316 SS. Consult the factory.

130/135

GB 3.05 MagFlux 071116

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Data Sheet
Flow Sensor 7300
Housing: Carbon steel Lining: PTFE

Electromagnetic Flow Meter


140/145 Size A

Sizes and Ordering information

Sizes and Ordering Information Size Pressure A DN [inch] PN [mm] 3 1/8 10 105 6 " 10 105 8 5/16 10 105 10 3/8" 10 105 15 " 40 62 20 3/4" 40 62 25 1" 40 72 32 1" 40 82 40 1" 40 92 50 2" 16 107 65 2" 16 127 80 3" 16 142 100 4" 16 162 125 5" 16 192 150 6" 16 218 200 8" 16 274 L [mm] 100 100 100 100 74 74 104 104 104 104 104 104 104 134 134 219 Weight [kg] 2 2 2 2 1,1 1,1 1,5 1,8 2,2 2,8 3,2 3,5 4 6 8 10 Order no. 207301 207302 207303 207304 207307 207310 207313 207316 207319 207322 207325 207328 207331 207334 207337 207340

Specications

Specications Mounting Materials Housing Lining Electrodes Accuracy Media temp. range Ambient temp. range Compact converter Remote converter Enclosure Wafer Carbon steel PTFE 1,4571 / AISI 316 TI Better than 0,25 % -20150 C / 0300 F -1060 C / 15140 F -20100 C / 0200 F IP67 / NEMA 4

Hastelloy C4, platinium, and titanium. Consult the factory. Of measured value. From DN 50 / 2 and up, built in ground electrode. Also available in Steel 304/316 SS. Consult the factory. Standard for DN 3 - 10 / 1/8 - 3/8 is AISI 316 TI.

GB 3.05 MagFlux 071116

10

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Data Sheet
Flow Sensor 7400
Housing: Carbon steel Lining: Hard rubber

Electromagnetic Flow Meter


140/145 Size A

Sizes and Ordering information

Sizes and Ordering Information Size Pressure A L DN [inch] PN [mm] [mm] 15 " 40 62 74 20 3/4" 40 62 74 25 1" 40 72 104 32 1" 40 82 104 40 1" 40 92 104 50 2" 16 107 104 65 2" 16 127 104 80 3" 16 142 104 100 4" 16 162 104 125 5" 16 192 134 150 6" 16 218 134 200 8" 16 274 219 Weight Order no. [kg] 1,1 207407 1,1 207410 1,5 207413 1,8 207416 2,2 207419 2,8 207422 3,2 207425 3,5 207428 4 207431 6 207434 8 207437 10 207440

Specications

Specications Mounting Materials Housing Lining Electrodes Accuracy Media temp. range Ambient temp. range Compact converter Remote converter Enclosure Wafer Carbon steel Hard rubber 1,4571 / AISI 316 TI Better than 0,25 % -1080 C / 15175 F -1060 C / 15140 F -1080 C / 15175 F IP67

Hastelloy C4, platinium, and titanium. Consult the factory. Of measured value. From DN 50 / 2 and up, built in ground electrode. Also avalible in Steel 304/316 SS. Consult the factory.

GB 3.05 MagFlux 071116

11

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Data Sheet
Flow Sensor 7600
Housing: Carbon steel Lining: Soft rubber

Electromagnetic Flow Meter

D Size

Sizes and Ordering information

Sizes and Ordering Information - EN Flanges Size DN 15 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 900 1000 1200 Pressure PN 40 40 40 40 40 16 16 16 16 16 16 16 10 10 10 10 10 10 10 10 6 6 6 6 D [mm] 95 105 115 140 150 165 185 200 220 250 285 340 395 445 505 565 615 670 780 895 1015 1115 1230 1450 L Weight [mm] [kg] 200 3,5 200 3,5 200 3,5 200 6 200 7 200 8 200 10 200 12 250 16 250 21 300 28 350 35 450 43 500 55 550 66 600 94 600 105 600 122 600 158 700 230 800 325 900 420 1000 510 1200 680 Order no. 207607 207610 207613 207616 207619 207622 207625 207628 207631 207634 207637 207640 207643 207646 207649 207652 207655 207658 207661 207664 207667 207670 207673 207676

Sizes and Ordering Information - ANSI Flanges Size [inch] " 3/4" 1" 1" 1" 2" 2" 3" 4" 5" 6" 8" 10" 12" 14" 16" 18 20 24 28 32 36 40 48 Pressure D [psi] [mm] 150 90 150 100 150 110 150 120 150 130 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 180 190 230 255 280 345 405 485 535 600 635 700 815 930 1050 1170 1275 1510 L Weight [mm] [kg] 200 3,5 200 3,5 200 3,5 200 6 200 7 200 8 200 200 250 250 300 350 450 500 550 600 600 600 600 600 800 800 800 1000 10 12 16 21 28 35 43 55 66 94 105 122 158 230 325 420 510 680 Order no. 297607 297610 297613 297616 297619 297622 297625 297628 297631 297934 297937 297940 297643 297646 297649 297652 297655 297658 297661 297664 297667 297670 297673 297676

PN 25-40-64. Consult the factory.

300-600 psi. Consult the factory.

Specications

Specications - EN / ANSI Flanges Mounting Materials Housing Flanges Lining Electrodes Accuracy Media temp. range Ambient temp. range Compact converter Remote converter: Enclosure Flange EN-1092-1 / ANSI B 16.5 Carbon steel Carbon steel Soft rubber 1,4571 / AISI 316 TI Better than 0,25 % -1080 C / 15175 F -1060 C / 15140 F -1080 C / 15175 F IP67, IP68 / NEMA 4, NEMA 6P

Hastelloy C4, platinium, and titanium. Consult the factory. Of measured value. From DN 50 / 2 and up, a ground electrode is built in. Also avalible in Steel 304/316 SS. Consult the factory.

130/135

GB 3.05 MagFlux 071116

www.mjk.com
12
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Data Sheet
Grounding Rings

Electromagnetic Flow Meter


b

d D

Sizes and Ordering information

Sizes and Ordering Information Size D d b DN [inch] [mm] 15 " 50 22 6 20 " 60 28 6 25 1" 71 35 6 32 1" 82 43 6 40 1" 92 49 6 50 2" 107 61 6 65 2" 127 77 6 80 3" 142 90 6 100 4" 162 115 6 125 5" 192 141 6 150 6" 218 170 6 200 8" 273 220 6 250 10" 328 274 6 300 12" 378 325 6 350 14" 438 360 6 400 16" 489 411 6 450 18 539 463 6 500 20 594 514 6

Weight Order no. [kg] 0,06 207807 0,08 207810 0,1 207813 0,13 207816 0,16 207819 0,2 207822 0,26 207825 0,32 207828 0,4 207831 0,5 207834 0,6 207837 0,8 207840 1,0 207843 1,2 207846 1,4 207849 1,6 207852 1,8 207855 2,0 207858

Specications

Specications Material Wire

AISI 316 SS 2,5 mm2 / AWG 13

GB 3.05 MagFlux 071116

13

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Data Sheet
Flow Sensor Sizing

Electromagnetic Flow Meter


Min. / Max. Flow and Default mA Settings Size DN 3 6 8 10 15 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 900 1000 1200 [inch] 1/8 " 5/16 3/8 " 3/4" 1" 1" 1" 2" 2" 3" 4" 5" 6" 8" 10" 12" 14" 16" 18 20 24 28 32 36 40 48 Qmin = 0,2 m/s 5,09 20,4 36,2 56,5 127 226 353 579 905 1414 2,39 3,62 5,65 8,84 12,7 22,6 35,3 50,9 69,3 90,5 115 141 204 277 362 458 565 814 Qmax = 10 m/s [l/h] 254 1018 1810 2827 6362 11304 17676 28944 45360 70560 [m3/h] 119 181 283 442 636 1131 1767 2545 3464 4524 5726 7069 10179 13854 18095 22902 28274 40715 20 mA 250 1000 2000 5000 5000 10000 20000 30000 50000 75000 100 200 300 400 600 1000 2000 2500 3000 4500 6000 7000 10000 15000 20000 25000 30000 40000

Flow Sensor Sizing Example

To calculate the correct size of the Flow Sensor the recomended ow velocity should be between 1 and 3 m/s to achieve high accuracy at low velocities (down to 0,2 m/s), to ensure safe operation of the tube system and to minimize pressure losses. The ow curves and graphs on the following page illustrate how the size of the Flow Sensor is calculated to get the required measuring accuracy.

Example A volume of 50 m/h is running through a pipe that measures 100 mm in internal diameter. To select the correct MagFlux Flow Sensor, the liquid velocity should be in the range 1 - 3 m/s for 50 m/hr. If a MagFlux Flow Sensor with the same internal diameter as the pipe is selected (100 mm), the ow velocity will be 1.5 m/s at a ow rate of 42 m/h. The diagram and table below also shows that a ow between 5.65 m/h and 283 m/h can be measured.

GB 3.05 MagFlux 071116

14

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

Data Sheet
Flow / Velocity Graph (metric)

Electromagnetic Flow Meter

Nominal diameter of MagFlux ow sensor


DN 700 - 28" DN 800 - 32" DN 900 - 36" DN 1000 - 40"
20000 30000

Fluid velocity [m/s]


10 9 8 7 6 5 4 3 2

1,5
1 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2

0,1

0,5 0,6 0,7 0,8 0,9 1

DN 100 - 4"

DN 250 - 10"

DN 8 - 5/16"

DN 10 - 3/8"

DN 50 - 2"

DN 150 - 6"

4000

0,01

0,02

0,03

0,04

0,05 0,06 0,07 0,08 0,09 0,1

5000 6000 7000 8000 9000 10000

5 6 7 8 9 10

20

30

40

50 60 70 80 90 100

5.65

42

283

Flow [m/h]

Measurement Accuracy Example: If a 100 mm MagFlux Flow Sensor is selected, the diagram shows the available measuring accuracy between 0.2 - 10 m/s (here: 0.25%).
Accuracy

[%]
5 4 3 2 1

0.25

0 0,1

0,2

0,5

10 m/s

GB 3.05 MagFlux 071116

15

www.mjk.com
DK: NO: SE: NL: USA: AUS: +45 45 56 06 56 +47 69 20 60 70 +46 53 31 77 50 +31 251 672171 +1 847 482 8655 +61 3 9758 8533

40000

600 700 800 900 1000

200

300

2000

3000

400

0,3

0,2

0,4

500

DN 1200 - 48"

DN 32 - 1 1/4"

DN 40 - 1 1/2"

DN 65 - 2 1/2"

DN 350 - 14" DN 400 - 16" DN 450 - 18" DN 500 - 20"

DN 300 - 12"

DN 80 - 3"

DN 200 - 8"

DN 600 - 24"

100
DN 125 - 5"

DN 15 - 1/2"

DN 20 - 3/4"

DN 3 - 1/8"

DN 6 - 1/4"

DN 25 - 1"

Data Sheet
Reducing the Flow Meter Size

Electromagnetic Flow Meter


When the size of the Flow Meter is reduced to cause the ow to reach a sufcient velocity, the pipe size has to be reduced. This will cause a pressure loss which can be calculated using the pressure loss chart at the right. When the MagFlux Sensor is smaller than nominal pipe diameter, the pressure loss can be checked, using the pressure loss chart. Example: A MagFlux Flow Sensor with an internal diameter of 80 mm is selected and the pipe size is 100 mm. Consequently the uid velocity for a ow of approximately 50m3/h will increase to about 3 m/s (see graph on page 11). Using a DN80 mm MagFlux ow sensor also leads to a smaller measurement range (3.62 m3/h - 181 m3/h). See graph on page 11. The diagram on the right shows that reducing the pipe size from 100 to 80 mm will cause a pressure loss of 3 mbar (0.003 bar).
< 7,5 DO DN

[bar]

Pressure loss graph

0,003

Sensor Mounting Conditions

Accurate ow measurement requires a minimum of tree (3) pipe diameters of straight pipe upstream and two (2) pipe diameters of

straight pipe downstream from the center of the Flow Sensor.

Minimum pipe diameter distances for accurate MagFlux ow measurements: Min. 3 x Diameter inlet Min. 2 x Diameter outlet

GB 3.05 MagFlux 071116

Distributed by:

MJK ofces

Denmark www.mjk.dk mjk@mjk.dk +45 45 56 06 56 Norway www.mjk.no mjk@mjk.no +47 69 20 60 70

The Netherlands www.mjk.com mjknl@mjk.com +31 251 672171 Sweden www.mjk.se kontoret@mjk.se +46 53 31 77 50

North America www.mjk.com mjkusa@mjk.com +1 847 482 8655 Australia www.mjk.com mjk@mjk.com +61 3 9755 1529

Potrebbero piacerti anche