GAUGE CLUSTER
12-1
SL6000
SL6000
12-2
12.1
CONFIGURATION OF DISPLAY
NORMAL DISPLAY
DISPLAY SCREEN SELECTOR SWITCH
Displayed only when the double drum switch is ON side. When the double drum switch is OFF side, this display screen is skipped.
Setting switch
Displayed only when the machine is equipped with the wind sensor in the optional setup.
Displayed only when the machine is equipped with the lifting height indicator in the optional setup.
Setting switch
FAULT INDICATOR
FAULTY
WARNING 4 (1)
Setting switch
Setting switch
12-3
SL6000
12.2
PRIORITY
1. All the display items are divided into seven groups, A to G. The priority is given to them in the alphabetical order, A (highest) to G (lowest). 2. While the items in higher priority groups are displayed on the screen of the gauge cluster, the items in lower priority groups are not displayed. For example, while the "M/L stop release" (in the group A) is displayed on the screen, the "self check function" (in the ground E) is not displayed. The items in lower priority groups are displayed after the display of the items in higher priority groups is ended. 3. When some items in the same group are required to be displayed, they are displayed by turns. 4. The normal display is replaced by the display of the items in higher priority groups, since the normal display has the lowest priority. It can be forcibly displayed with flashing by pushing the zero switch, and holding it for 5 seconds or longer.
SL6000
12-4
Input delay *2 O O -
Buzzer alarm *3 O
1 A 2 3 4 B 5 6 7 C 8 9
Fuel gauge com- Fuel gauge com19 LOW FUEL LEVEL (W-11)
- : Open level
- : No delay
: Buzzer sounds emission intermittently continues for 0.2 sec. with intervals of 0.3 sec (it cannot be stopped with the buzzer stop switch). O : Buzzer sounds emission intermittently continues for 0.5 sec. with intervals of 0.5 sec (it can be stopped with the buzzer stop switch). : Buzzer sounds emission intermittently continues for 0.2 sec. with intervals of 0.3 sec., and is stopped 5 sec. later. Blank: None *4. Normal display for other items except (G-25).
12-5
SL6000
12.3
STATUS DISPLAY
No.1 MAIN CONT. P/N JG30S00001D1 PROGRAM VER VER 0.07
The current machine statuses can be displayed on the liquid crystal display screen of the gauge cluster by using the data from the total controller. Fifty-two types of display screens are available {refer to CONTENTS OF STATUS DISPLAY (Main total controller), CONTENTS OF STATUS DISPLAY (Sub total controller)}.
Procedures 1. Start the engine. 2. Push both of the check switch and buzzer switch at the same time, and hold them for 5 seconds or longer. First, the No.1 items, parts code of the total controller and program version, are displayed. While the items in the group A or B are displayed, the machine does not enter the status display mode. Correct the conditions that lead to the display of the items in group A or B. 3. Whenever the display screen selector switch is pushed, the screen is scrolled up once, while it is scrolled down once whenever the display screen selector switch is pushed. When the display screen selector switch or is left pushed, the screen is scrolled continuously. 4. To end the status display mode, push the setting switch. Then, the screen returns to the normal display. 5. If the key switch is not set to the "OFF" position and the status display mode is actuated again, the screen which had been displayed just before the normal screen was returned appears. If the key switch is set to the "OFF" position, the No.1 screen appears.
CHECK SWITCH BUZZER SWITCH SETTING SWITCH DISPLAY SCREEN SELECTOR ( ) SWITCH
The STATUS DISPLAY can display the status of the main total controller or the status of the sub total controller. It is selected which status is displayed on the screen by the monitor display selector switch. The monitor display selector switch is located at the switch panel on left side wall in operator's cabin.
SL6000
12-6
ENGINE PRS. LIVE No.3 A-7 GRIP VOLT. POS. 4.2V 100% The values are changed depending on the hand throttle operation, low or high.
With E/G oil pressure: LIVE No E/G oil pressure: DEAD The components are norLow 0.5V 0% High 5.0V 100% mal if the values of the "POS." are changed between 0 and 100% when the E/G speed is changed between low and high. *If they are not changed to 0 or 100%, re-adjust.
MOTOR STEP 256 POS. No.4 STEP. MOTOR F-1 COIL-A F-2 COIL-B LIMIT No.5 DIGITAL OUTPUT C-1 COMP. MEAS. C-2 COMP. MEAS. No.6 DIGITAL OUTPUT C-3 COMP. MEAS C-4 COMP. MEAS. No.7 DIGITAL OUTPUT MAIN PUMP INCHING C-5 COMP. MEAS. C-6 COMP. MEAS. No.8 DIGITAL OUTPUT C-7 COMP. MEAS. C-8 COMP. MEAS. OFF OFF OFF LEVER SELECTION OFF PATTERN CHANGE SOL.2 Conditions other than the above. OFF LEVER SELECTION PATTERN CHANGE SOL.1 OFF OFF The state of lever selection pattern change solenoid 1 (SOL75) is displayed. When the lever selection pattern is W1 winch and W3 winch. Conditions other than the above. The state of lever selection pattern change solenoid 2 (SOL76) is displayed. When the lever selection pattern is W1 winch and W3 winch. ON ON OFF SOL. When the main, aux., and third winch control levers are at the neutral positions and the inching switch is turned on. Conditions other than the above, or in the free fall mode. ON OFF OFF OFF OFF OFF The boom control lever is at the neutral position, or the inching BOOM PUMP INCHING SOL. switch is turned on. When the conditions other than the above are not satisfied. ON OFF SPARE OFF OFF SPARE SPARE 1.0A 1.1A OFF NO USE COMMAND TO ECU The set valves are changed depending on the position of the throttle. Low 1.0V High 4.0V 100% NO USE
Although the unit shown on the display is "A", the actual unit is "V".
* COMP.: command value from controller * MEAS.: feed back value The fault (disconnection) is indicated by displaying the following codes COMP.OFF MEAS.ON Connector voltage ON : 24 V OFF : 6 to 8V (disconnection) Check procedures 1) Measure the voltage at the connector. 2) Measure the resistance of the solenoid valves. 3) Replace with nearby solenoid valves and connectors.
12-7
SL6000
SL6000
12-8
12-9
SL6000
The current at the proportional valve is decreased to 150 mA depending on the boom angle. At the stop: 150mA Trimmer min. value 410mA 460mA Trimmer max. value 625mA 625mA
When the hook overhoist is released : 375mA At the stop: 150mA At the stop: 150mA
The value is changed when the jib raising is stopped (due to The current at the proportional valve is dejib upper limit). The value is changed when the lever interlock is actuated. creased to 150 mA depending on the jib angle. At the stop: 150mA Trimmer min. value E/G Low E/G High (due to overload and jib lower limit). The value is changed when the lever interlock is actuated. 379mA 439mA Trimmer max. value 625mA 625mA
NO.26 PROPO-VALVE D-8 COMP. 600mA 4.5MP MEAS. 600mA 4.5MP W2 DRUM LOWER SPEED CONTROL The value is changed according to the speed adjusting trimmer value.
The value is changed when the jib lowering is slowly stopped The current at the proportional valve is decreased to 150 mA in approximately 1.5 sec. At the stop: 150mA
SL6000
12-10
The value is changed when the HL mast raising is stopped (due to HL mast upper limit). The value is changed when the lever interlock is actuated.
The current at the proportional valve is decreased to 150 mA depending on the HL mast angle. At the stop: 150mA Smaller value shown in the left is effective during hoisting and lowering.
NO.30 PROPO-VALVE D-12 COMP. 600mA 4.5MP MEAS. 600mA 4.5MP NO. 31 PROPO-VALVE D-13 COMP. 600mA 4.5MP MEAS. 600mA 4.5MP NO.32 PROPO-VALVE D-14 COM. 600mA 4.5MP W3 DRUM LOWER SPEED CONTROL MEAS. 600mA 4.5MP The value is changed according to the speed adjusting trimmer value. E/G Low E/G High The value is changed when the HL mast lowering is slowly stopped (due to overload and HL mast lower limit). The value is changed when the lever interlock is actuated. NO.33 PROPO-VALVE D-15 COMP. 600mA 4.5MP MEAS. 600mA 4.5MP W1 MOTOR CONTROL When the hold pressure of the W1 motor continues 0.5 sec with 33.3 MPa or more. It returns with hold pressure 22.5MPa or less. 250mA (constant) Trimmer min. value 379mA 439mA Trimmer max. value 625mA 625mA SPARE SPARE
The current at the proportional valve is decreased to 150 mA in approximately 1.5 sec. At the stop: 150mA Trimmer voltage 0V 1.5V 5.0V Proportional valve current 250mA 250 to 600mA 250 to 600mA
12-11
SL6000
SL6000
12-12
A-14
3.5V
A-15
3.5V
A-16 NO.38
3.5V
ANALOG INPUT A-21 A-22 A-23 A-24 NO.40 ANALOG INPUT A-25 A-26 NO.41 DIGITAL INPUT B-1 B-2 B-3 B-4 OFF OFF OFF OFF OPERATION LEVER PATTERN 1 SPARE DOUBLE DRUM SPARE The double drum function is switched. Double drum : ON Normal : OFF 3.5V 3.5V W1 LOWER PRESS. SENSOR SPARE The lever is at the neutral position. The lever is fully operated. 0.5V 4.3V 3.5V 3.5V 3.5V 3.5V
* The components are The operation lever pattern is switched. ON : ON ON : OFF normal if the values are changed when the respective conditions are satisfied.
12-13
SL6000
SL6000
12-14
* 1The LMI bypass switch is effective ("ON" is displayed) only when it is set to the "Bypass" position and the LMI is malfunctioned, and it is ineffective even if it is set to the "ON" position when the LMI operates normally.
12-15
SL6000
ENGINE PRS. LIVE No.3 A-7 GRIP VOLT. POS. 4.2V 100% The values are changed depending on the hand throttle operation, low or high.
With E/G oil pressure: LIVE No E/G oil pressure: DEAD The components are norLow 0.5V 0% High 5.0V 100% mal if the values of the "POS." are changed between 0 and 100% when the E/G speed is changed between low and high. *If they are not changed to 0 or 100%, re-adjust.
MOTOR STEP 256 POS. No.4 STEP. MOTOR F-1 COIL-A F-2 COIL-B LIMIT No.5 DIGITAL OUTPUT C-1 COMP. MEAS. C-2 COMP. MEAS. No.6 DIGITAL OUTPUT UPPER TRANSLIFTER C-3 COMP. MEAS C-4 COMP. MEAS. No.7 DIGITAL OUTPUT UPPER TRANSLIFTER C-5 COMP. MEAS. C-6 COMP. MEAS. No.8 DIGITAL OUTPUT C-7 COMP. MEAS. C-8 COMP. MEAS. OFF OFF OFF OFF PARKING BRAKE RELEASE SIGNAL CLUSTER GAUGE DISPLAY SWITCH OFF OFF The controller on the side displayed to the cluster gauge is selected. When the sub controller is selected. When the main controller is selected. The state of the parking brake release signal is displayed. When parking brake is released. conditions other than the above. ON OFF ON OFF SOL 4 When upper translifter cylinder is extended and operated. (SOL-95) conditions other than the above. ON OFF OFF OFF OFF SOL 2 When upper translifter cylinder is extended and operated. (SOL-93) conditions other than the above. When upper translifter cylinder is extended and operated. UPPER TRANSLIFTER SOL 3 (SOL-94) conditions other than the above. ON OFF ON OFF OFF OFF BATTERY RELAY It remains set to the "ON" while the power is supplied. 1.0A 1.1A OFF NO USE COMMAND TO ECU The set valves are changed depending on the position of the throttle. Low 1.0V High 4.0V 100% NO USE
Although the unit shown on the display is "A", the actual unit is "V".
* COMP.: When upper translifter cylinder is extended and operated. UPPER TRANSLIFTER SOL 1 (SOL-92) conditions other than the above. ON OFF * MEAS.: feed back value The fault (disconnection) is indicated by displaying the following codes COMP.OFF MEAS.ON Connector voltage ON : 24 V OFF : 6 to 8V (disconnection) Check procedures OFF 1) Measure the voltage at the connector. 2) Measure the resistance of the solenoid valves. 3) Replace with nearby solenoid valves and connectors. command value from controller
SL6000
12-16
12-17
SL6000
SL6000
12-18
Check procedures 1) Measure the current value at the connector clamp with a meter. 2) Measure the voltage of the controller internal detection resistance. Measure the proportional valve resistance. Replace with nearby solenoid valves and connectors.
12-19
SL6000
MEAS. 600mA 4.5MP NO.33 PROPO-VALVE D-15 COMP. 600mA 4.5MP MEAS. 600mA 4.5MP SPARE
SL6000
12-20
12-21
SL6000
SL6000
12-22
12-23
SL6000
SL6000
12-24
12.4
The logs of faults which have been found by the self check of the total controller are stored in the controller, and can be displayed on the display screen of the gauge cluster. If faults do not re-appear on job sites, first, check the fault log display for the convenience of troubleshooting. 1. Display procedures (1) Set the key switch to the "ON" position. (2) Enter the fault finding mode. (Push both of the check switch and buzzer switch at the same time and hold them for 5 sec. or longer.) (3) Push the check switch and hold it for 5 sec. or longer while the machine is in the status display mode. Then, the fault logs are displayed.
NO ERROR
12-25
SL6000
12. GAUGE CLUSTER (4) The displayed fault logs remain displayed on the screen for an hour. If there are four or more fault logs to be displayed at a time, the displayed fault logs are changed automatically.
(Example) (a)
5000 A-2 C-7 F-1 Hr A/I ERROR D/O ERR S/M ERROR
(5) To display the logs of faults occurred at other time (for example, logs of faults occurred at the time other than 5000 Hr), switch the display with the display screen selector switch or . Former fault logs can be displayed by pushing the display screen selector switch , and later logs can be displayed by pushing the display screen selector switch .
(6) To end the fault log display, push the setting switch. Then, the status display mode returns.
2. Deletion of fault logs (1) Display the fault logs occurred. (2) Push the zero switch and hold it for 5 sec. or longer. All the fault logs occurred are deleted. (3) After the deletion is completed, the message "NO ERROR" appears on the display screen.
SL6000
12-26
12. GAUGE CLUSTER 3. Notes on fault logs Even when a fault occurs, if the same type fault already occurred in the past, and the log of the fault has already been stored, a new log of the fault is not stored. The hour indicated in the hourmeter on the display is a reference (for the replacement of the controller), and indicates the total period of the controller operation. It is not related to the hourmeter on the carrier.
Owing to the facts above, be sure to delete fault logs after faults are corrected. It is recommended to record the hourmeter value of the controller together with that of the hourmeter of the carrier.
12-27
SL6000
12. GAUGE CLUSTER 4. Contents of fault log display (Main controller) CONTENTS OF DISPLAY A-1 A-2 A-3 A-6 A-9 A-10 A-11 A-12 A-13 A-14 A-15 A-16 A-17 A-18 A-19 A-20 A-22 A-24 A-25 C-4 C-5 C-7 C-8 C-15 C-16 C-17 C-18 C-19 C-26 C-27 C-28 A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR USE H1 winch motor speed adjusting trimmer H2 winch motor speed adjusting trimmer W1 winch motor speed adjusting trimmer W3 winch motor speed adjusting trimmer W3 winch raising pressure sensor W3 winch lowering pressure sensor W1 winch motor pressure sensor W2 winch motor speed adjusting trimmer H1 winch raising pressure sensor H1 winch lowering pressure sensor H2 winch raising pressure sensor H2 winch lowering pressure sensor W2 winch raising pressure sensor W2 winch lowering pressure sensor Inclination sensor (X) Inclination sensor (Y) Wind alarm output W1 winch raising pressure sensor W1 winch lowering pressure sensor Boom pump inching solenoid Maim pump inching solenoid Lever pattern change solenoid 1 Lever pattern change solenoid 2 H1 winch motor boost solenoid H2 winch motor boost solenoid W1 winch motor boost solenoid H1 winch drum turn detection grip H2 winch drum turn detection grip Lever selection pattern indicator lamp 1 Lever selection pattern indicator lamp 2 Lever selection pattern indicator lamp 3
SL6000
12-28
12. GAUGE CLUSTER CONTENTS OF DISPLAY D-1 D-2 D-3 D-4 D-5 D-6 D-7 D-8 D-9 D-10 D-11 D-14 D-15 H-3 H-4 H-5 H-6 H-7 P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR ROM DATA MEC. SET M/L RECEIVE MEC. RECEIVE MEC. -B. REV NO ERROR USE W1 remote control raising pressure reducing proportional valve W1 remote control lowering pressure reducing proportional valve H1 remote control raising pressure reducing proportional valve H1 remote control lowering pressure reducing proportional valve H2 remote control raising pressure reducing proportional valve H2 remote control lowering pressure reducing proportional valve W2 remote control raising pressure reducing proportional valve W2 remote control lowering pressure reducing proportional valve H1 winch motor tilting angle proportional valve H2 winch motor tilting angle proportional valve W3 remote control raising pressure reducing proportional valve W3 remote control lowering pressure reducing proportional valve W1 winch motor tilting angle proportional valve Abnormal total controller adjustment value Wrong total controller adjustment Faulty communication with LMi Faulty communication with total controller Sub total controller is abnormal
12-29
SL6000
12. GAUGE CLUSTER 5. Contents of fault log display (Sub controller) CONTENTS OF DISPLAY A-1 A-6 A-7 A-11 A-12 A-17 A-18 A-26 C-1 C-2 C-3 C-4 C-5 C-7 C-8 C-10 C-11 C-13 C-14 C-15 C-18 C-19 C-20 C-21 C-22 C-23 C-25 C-26 C-28 A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR A/I ERROR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR D/O ERR Hand throttle Foot throttle Swing pump pressure sensor H3 winch motor speed adjusting trimmer H3 winch raising pressure sensor H3 winch lowering pressure sensor Remote control accelerator Battery relay Upper translifter solenoid 1 Upper translifter solenoid 2 Upper translifter solenoid 3 Upper translifter solenoid 4 Cluster gauge display switch relay Parking brake release relay HL mast backstop relief pressure change solenoid Carry over solenoid Swing brake mode change relay HL mast backstop solenoid (EXT.) HL mast backstop solenoid (RET.) Upper translifter solenoid 5 Upper translifter solenoid 6 Upper translifter solenoid 7 Upper translifter solenoid 8 Swing relief pressure shift solenoid HYD. change solenoid H3 feathering release H3 winch motor boost solenoid ECU state maintenance USE HL mast backstop cylinder pressure sensor
SL6000
12-30
12. GAUGE CLUSTER CONTENTS OF DISPLAY D-1 D-2 D-3 D-4 D-5 D-6 D-7 D-8 D-9 H-3 H-4 H-5 H-6 P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR P/V ERR ROM DATA MEC. SET M/L RECEIVE MEC. RECEIVE NO ERROR Swing speed proportional valve Swing reaction proportional valve Right swing proportional valve Left swing proportional valve Main pump reducing horsepower proportional valve Boom pump reducing horsepower proportional valve H3 winch motor tilting angle proportional valve H3 remote control raising pressure reducing proportional valve H3 remote control lowering pressure reducing proportional valve Abnormal total controller adjustment value Wrong total controller adjustment Faulty communication with LMi Faulty communication with total controller USE
12-31
SL6000
SL6000
12-32