Sei sulla pagina 1di 217

General

catalogue

INDEX

SURFACE PUMPS
EP.....................................................................4
CM....................................................................5
CB.....................................................................6
CM DIN 24255 .................................................7
JETINOX ........................................................14
NEW JET........................................................16
JET .................................................................17
AP...................................................................19

MCX ...............................................................20
DHR................................................................23
DHI .................................................................25
MAX ...............................................................27
MULTINOX-A VE ...........................................29
VLR - VLRI - VLRX ........................................31
VLR ACESSORIES ........................................63

CIRCULATION PUMPS - HEATING AND AIR-CONDITIONING


SR3.................................................................65
R2S 25............................................................67
R2S.................................................................69
R2SD ..............................................................71
R2X R2B ........................................................73
R2C R4C........................................................75

R2CD R4CD...................................................85
R2T R4T .........................................................95
R2TD R4TD..................................................105
A2L A4L .......................................................115
A2LD A4LD....................................................121
CIRCULATION PUMP ACCESSORIES........128

SUMP, SEWAGE AND EFFLUENT PUMPS


DRENOX ......................................................132
OMNIA..........................................................133
SOM .............................................................134
PRIOX ..........................................................135
MINIVORT P ................................................136
MINIVORT PP ..............................................137

4" SUBMERSIBLE MOTORS......................183


SA 6 ............................................................184
CABLE SELECTION
FOR SUBMERSIBLE MOTORS ..................189

PUMPS FOR SPECIAL USES


VERSAILLES................................................192
VERSAILLES ACCESSORIES.....................193

SOM VORT ..................................................138


VITEX SB ....................................................139
VITEX SP......................................................149
VITEX OM ....................................................159
VITEX ACCESSORIES ................................166
VACUSYSTEM.............................................217

PUMPS FOR OPEN AND DRILLED WELLS


PRATIKA .....................................................168
DOMINATOR 4"...........................................169
DOMINATOR 5"...........................................170
SCM 4 PLUS................................................172
SCM 4 PLUS PUMP - ENDS...................... 181

PGA DELTA-OIL ..........................................191


PGA DELTA-OIL ACCESSORIES ...............191

PRESSURE ASSEMBLIES
SIZING HOME WATER SYSTEMS .............195

WATERPRESS INOX 50L............................202

PIPE FRICTION LOSS CHARTS.................197

WATERPRESS SUPERINOX.......................204

WATERPRESS .............................................198
WATERPRESS INOX ...................................200

ACCESSORIES
HYDRAULIC ................................................207
ELECTRICAL ...............................................210
CONTYROL PANELS ..................................211

CONTENTS IN ALPHABETIC ORDER

A2L A4L........................................................115
A2LD A4LD...................................................121
ACCESSORIES CIRCULATION PUMPS . 128
ACCESSORIES ELECTRICAL ..................210
ACCESSORIES HYDRAULIC ...................207
ACCESSORIES PGA - DELTA OIL ...........191
ACCESSORIES VERSAILLES ...................193
ACCESSORIES VITEX ..............................166
ACCESSORIES VLR ....................................63

OMNIA .........................................................133

PRIOX ..........................................................135
PGA - DELTA OIL ........................................191
PRATIKA ......................................................168
PIPE FRICTION LOSS CHARTS.................197

R2C R4C ........................................................75


R2CD R4CD...................................................85
R2S.................................................................69
R2S 25............................................................67
R2SD ..............................................................71
R2T R4T .........................................................95
R2TD R4TD..................................................105
R2X R2B ........................................................73

SA 6 ............................................................184
SCM 4 PLUS................................................172
SOM .............................................................134
SOMVORT ...................................................138
SR3.................................................................65
SIZING HOME
WATER SYSTEMS.......................................195
SCM 4 PLUS PUMP-ENDS.........................181
4" SUBMERSIBLE MOTORS......................183

VACUSYSTEM.............................................217
VERSAILLES................................................192
VITEX OM ....................................................159
VITEX SB .....................................................139
VITEX SP......................................................149
VLR.................................................................31
VLRI................................................................43
VLRX ..............................................................51

WATERPRESS ............................................198
WATERPRESS INOX...................................200
WATERPRESS INOX 50L............................202
WATERPRESS - SUPERINOX ....................204

AP...................................................................19

CABLE SELECTION FOR


SUBMERSIBLE MOTORS .........................189
CB ....................................................................6
CM....................................................................5
CM DIN 24255 .................................................7
CONTROL PANELS......................................211

DHI ................................................................25
DHR ...............................................................23
DOMINATOR 4"...........................................169
DOMINATOR 5"...........................................170
DRENOX ......................................................132

EP.....................................................................4

JET .................................................................17
JETINOX ........................................................14

MAX ...............................................................27
MCX ...............................................................20
MINIVORT P ................................................136
MINIVORT PP ..............................................137
MULTINOX - A - VE.......................................29

NEWJET.........................................................16

SURFACE PUMPS
50 Hz

EP

SURFACE PUMPS
PERIPHERAL PUMPS
The EP series peripheral monobloc pumps are
especially suitable where high heads with limited
flow rates need to be developed.
Design Features
-Cast iron pump casing
-Cast iron motor bracket
-Brass impeller
-Stainless steel shaft
-Graphite mechanical seal with ceramic
counterface
Motor
-Enclosed, externally ventilated
-Level of protection IP 44
-Class F insulation
-Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
-Three phase power supply with external
protection provided by the user
-Speed of rotation 2850 rpm
-Suitable for continuous use

70
60
50

40

Usage Limitations
-Type of liquid: clean water with no suspended
solids or abrasive material
-Maximum liquid temperature 70C
-Maximum recommended suction height 5 m
with foot valve
-Maximum operating pressure 6.5 bar

30

20
10

Applications
-Small-scale booster systems
-Domestic autoclaves
-Small-scale irrigation
-Washing systems

Hm
Q

30
1,8

20
1,2

10
0,6

L / 1'
m3/ h

50
3

40
2,4

60
3,6

70
4,2

Dimensions mm.

Model
A

80
4,8

Weight

DNA

DNM

kg

EP2

260

85

100

145

135

1"

1"

6,8

EP4

295

90

112

156

150

1"

1"

11

MODEL

Nominal Absorbed
Power
Power
HP

kW

HP

VOLTAGE

Amp.

L/1'

10

20

30

40

50

60

0,3

0,6

1,2

1,8

2,4

3,6

42

37

27

17

59

55

46

37

28

19

Q
m /h

kW

N4162010
N4162020

EP2 M
EP2 T

0,5 0,37 0,75 0,55 1 ~ 220240 V


3 ~ 230400 V

2,9
1,6-0,9

N4164010
N4164020

EP4 M
EP4 T

0,75 0,55 1,6 1,2

1 ~ 220240 V
3 ~ 230400 V

5
3,8-2,2

16

Discharge head
in meters

CODE

PRICE

CM

SURFACE PUMPS
HORIZONTAL SINGLE-STAGE
CENTRIFUGAL PUMPS
The CM series single impeller centrifugal pumps
are silent and have a high hydraulic efficiency.
Design Features
- Cast iron pump casing
- Cast iron motor bracket
- Brass impeller (model CM 90/22 in
technopolymer)
- Stainless steel shaft
- Graphite mechanical seal with ceramic
counterface
- Stainless steel seal holder plate
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use

70
60
50

130/51
110/44
10 0 / 3 6

40
30

Usage Limitations
- Type of liquid: non-abrasive clear or slightly
cloudy water
- M a x i m u m l i q u i d t e m p e r a t u re 9 0 C
(model CM 90/22 50C)
- Maximum recommended suction height 5 m
with foot valve
- Maximum operating pressure:
6 bar for models HP 0.5 - 0.75
8 bar for models HP 1 - 1.5 - 2

9 0/ 2 2

20
10
Hm
Q

60

40

20

L / 1'
m3/ h

100
6

80
4

120

140
8

160

Applications
- Pumping from wells for irrigation
- Booster systems
- Domestic autoclaves
- Washing systems

Dimensions mm.

Model
A

Weight

75

43

267

150

110

160

82

202

CM 100/36

82

44

310

180

140

185

97

232

CM 110/44

88

45

350

194

155

200

100

252

CM 130/51

88

45

350

220

180

225

115

286

MODEL

Nominal Absorbed
Power
Power

VOLTAGE

Amp. F

0,75

1 ~ 220240 V
3 ~ 230400 V

3,6
2,4-1,4

12,5

CM 100/36 M
CM 100/36 T

1 0,75 1,7 1,25

1 ~ 220240 V
3 ~ 230400 V

5,5
3,8-2,2

20

N4187090
N4187100

CM 110/44 M
CM 110/44 T

1,5 1,1 2,6 1,9

1 ~ 230 V
3 ~ 230400 V

9,2
6,1-3,3

35

N4187110
N4187120

CM 130/51 M
CM 130/51 T

1 ~ 230 V
3 ~ 230400 V

10,8
7,8-4,5

40

CM 90/22 M*
CM 90/22 T*

N418B130
N418B140

0,5 0,35 1

1,5 3,1 2,3

10

30

50

80

100

120

0,6

1,8

3,0

4,8

7,2

22

20

18

13

35

33

31

26

22

42

40

38

33

29

51

50

48

44

40

m /h

HP KW HP KW

N418B090
N418B100

L/1'
Q

* TECHNOPOLYMER IMPELLER
5

Discharge head
in meters

CODE

DNA

CM 90/22

34

DNM

kg

1"

1"

6,5

1"

1"

11

1"1/4

1"

20,5

1"1/4

1"

23

PRICE

CB

SURFACE PUMPS
TWIN IMPELLER
CENTRIFUGAL PUMPS
The model CB Twin impeller centrifugal electric
pumps have two self balanced impellers to give
very high efficiency.
Design Features
- Cast iron pump casing
- Cast iron motor bracket
- Die cast aluminium support with stainless
steel back plate to hidraulic side (cast iron
only on models 1,5-2-3 HP)
- Noryl GFN2 impeller ( stamped brass impeller
on model 1,5-2-3 HP)
- Stainless steel motor shaft
- Graphite mechanical seal with ceramic
counterface

80
70

Motor
- Totally enclosed fan cooled motor to IP44
protection
- F class winding
- Stamped fan cover
- For singlephase models built in thermal
protector and permanently connected
capacitor

60

160/6
8
/65

120

50

110/
55
80/38 90/44

40
30

Usage Limitations
- Suction depth 5 mt.
- Max water temp.:
40 C for models 0,75-1 HP
90 C for models 1,5-2-3 HP
- Max pressure:
6 Bar 0,75-1 HP
10 Bar 1,5-2-3 HP

20
10
Hm
Q

L / 1'
m3/ h

20
1,2

40
2,4

60
3,6

80
4,8

100
6,0

120
7,2

160
9,6

140
8,4

180
10,8

Applications
- Domestic and industrial uses
- Booster systems
- Pumping from wells for irrigation
- Washing system

Dimensions mm.

Model

Weight

DNA

DNM

CB 80/38

66

73

346

180

140

180

97

227

1"

1"

14,3

CB 90/44

66

73

346

180

140

180

97

227

1"

1"

15,6

CB 110/55
CB 120/65
CB 160/68

74
74
74

86
86
86

400
400
400

195
195
195

155
155
155

214
214
214

110
110
110

265
265
265

1"1/4
1"1/4
1"1/4

1"
1"
1"

25,7
26
26,5

N4189010
N4189020

Nominal
Power

MODEL
CB 80/38 M *
CB 80/38 T *

Absorbed
Power

VOLTAGE

Amp.

F.

L/1'

kW

HP

kW

0,75

0,55

1,1

0,8

1 ~ 220 V
3 ~ 220380 V

4,4
2,6-1,5

1,6

5,5
3,8-2,2

20

N4189030
N4189040

CB 90/44 M *
CB 90/44 T *

0,74

1,6

1,2

1 ~ 220 V
3 ~ 220380 V

N4189050
N4189060

CB 110/55 M
CB 110/55 T

1,5

1,1

2,5

1,8

1 ~ 220 V
3 ~ 220380 V

8,5
6 -3,4

31,5

N4189070
N4189080

CB 120/65 M
CB 120/65 T

1,5

3,1

2,3

1 ~ 220 V
3 ~ 220380 V

10,5
7,3-4,2

31,5

N4189090

CB 160/68 T

2,2

3,8

2,8

3 ~ 220380 V

8,2-4,7

* TECHNOPOLYMER IMPELLER
6

20

40

60

80

100

120

140

160

1,2

2,4

3,6

4,8

7,2

8,4

9,6

35

31

26

18

40

37

31,5

24,5

54,5

51

46

39

30

64

60

55

49

41

32

67

64,5

61

57

52

46

39

32

kg

PRICE
3

m /h

HP

Altezza
manometrica
in m.c.a.

CODE

SURFACE PUMPS

CENTRIFUGAL PUMPS IN CONFORMANCE WITH DIN 24255


FOR USE IN THE CIVIL, AGRICULTURAL AND INDUSTRIAL FIELDS
The CM series is made up of single stage electric monobloc pumps with a flanged hydraulics/motor connection.
The pump casing is manufactured in accordance with the provisions of DIN 24255-NF E 44 III-UNI 7467 standards, regarding
hydraulic dimensions and connection points.
The pumps may be installed in all positions, except where the suction point is directed downwards.
The design of these machines allows the rotating parts and the motor to be removed from the pump casing without having to
disconnect the pipes. Thus any maintenance is easily and quickly performed.

STANDARD DESIGN FEATURES


- Cast iron pump casing GG20
- Cast iron motor bracket GG20
- Cast iron impeller (bronze on request)
- Stainless steel shaft pump AISI 304 or 303
- Mechanical seal with ceramic/graphite counterfaces
- Flanged connection points DN 32 - DN 80 as per UNI 2236
PN10 standards
- Threaded type counterflanges as per UNI 2254 standards

USAGE LIMITATIONS
Type of liquid: non-aggressive, non-explosive,
free from solid particles and fibres.
- Hot water for heating
- Coolants (not containing mineral oils) for airconditioning systems
- Pumped liquid temperature from -10 C to 90C
- Environmental temperature up to 40 C
- Maximum operating pressure 10 bar

MOTOR
- Type: induction, enclosed, self-ventilated
- Design: B5
- Use: continuous
- Insulation: Class F
- Level of protection: IP 55 Terminal Box
IP 44 complete motor
- Number of poles: 2
- Speed of rotation 2900 rpm

APPLICATIONS
- Agricultural: overhead or surface irrigation
water supply
- Civil: autoclave supply, pressure elevation,
heating and air-conditioning systems, water
supply and firefighting systems
- Industrial: liquid transfer in general

CM DIN 24255

DN
32
40
50
65
80
100

DIMENSIONS (mm)
Holes
D
K
n
Dia.
140
100
4
18
150
110
4
18
165
125
4
18
185
145
4
18
200
160
4
18
220
180
8
18

Dimensions mm

Weight
kg

Model
DNM

CM 32/160

CM 32/200

CM 32/250

CM 40/125

CM 40/160
CM 40/200
CM 40/250
CM 50/125
CM 50/160

CM 50/200

CM 50/250

CM 65/125

CM 65/160

CM 65/200

CM 65/250

CM 80/160

CM 80/200

C
B
A
C
B
A
C
B
A
C
B
A
B
A
B
A
B
A
B
A
B
A
C
B
A
C
B
A
B
A
C
B
A
C
B
A
B
A
D
C
B
A
B
A

DNA

H1

H2

132

160
100

80
32

50

100

M1

160

180

180

225

112

140

132

160

160

180

180

225

132

160

150

180

M2

70

N1

240

N2

190

50

65

125

95

320

250

210

160

240

190

265

212

320

250

240

190

65

65

100

100

70

125

100

95

70

490

240

292

268

340

305

405

495

220

252

500

245

292

590

273

340

630
700

322

405

525

250

292

590

270

340

505
565
625

14

695

50
14
15
65

50
265

160

12

12

100

50

14

80
40

12

212

14

200

635

290

360

332

405

705
180

225

125

95

320

250

65

14

750

180

605
280

160
200
65

80

125

95

100

635
65

14

14

100

125

340

290

360

330

405

370

450

705
180

225

200

250

160

120

320

250

360

280

320
80

212

280

180

225

125

80

250

16

345

280

19

14
16

850
665
735

14
65

95

750

330

780
870

405
355

38
39
42
52
63
69
83
90
120
36
37
40
47
50
65
71
91
121
47
50
65
71
82
89
122
125
140
149
64
70
84
90
120
122
138
148
239
253
99
129
143
152
233
247

CM 32

SURFACE PUMPS
20
100
90
80

15

30

40

20

30

50

100

40

50

Q (US. GPM)
100

200

300

Q (IMP. GPM)

200

400
300

500
400

750
500

1000
750
300

250 A

250

70

250 B

60

200

250 C

50

150
40

200 A

30

100

200 B
200 C

75
20

160 A
50

H (m)

160 C

160 B

40

10

H (ft)

10
9
8
7
6
5

30

250
0B A
16 160

200

25
20
15

C
160

3
NPSH
(m)
2

10
NPSH
(ft)
5

5
75

CODE

100

MODEL

9 10
150

15
200

300

Motor
Power

Q (m3h) 30

20

Q (l/min) 500

VOLTAGE

HP

kW

Amp.
3 X 400 V

D5732KKK

CM 32/160 C

1,5

3 ~ 230 400 V

D5733KKK

CM 32/160 B

2,2

3 ~ 230 400 V

5,2

D5734KKK

CM 32/160 A

3 ~ 230 400 V

7,1

D5735KKK

CM 32/200 C

5,5

3 ~ 230 400 V

9,4

D5736KKK

CM 32/200 B
5,5

3 ~ 230 400 V

14,2

7,5

D5737KKK

CM 32/200 B

D5738KKK

CM 32/200 A

10

7,5

3 ~ 400 690 V
3 ~ 230 400 V

16,5

40

50

60

750

70 80 90 100

1000

L/1'

1500

150
2000

200
3000

PRICE
3

m /h

24,7 24,1

9
23

12

18

24

30

36

37

28,7

21,5 17,2

29 28,5 27,3 25,7 21,4 14,8

36,8 36,4 35,4 34,2 31,1

41

40

53

52

38,8 37,5 34,2

51

50

26

30

46,8 42,7

61 60,5 59,5 58,5 55,5 51,5 46,2 38,5

3 ~ 400 690 V

D5739KKK

CM 32/200 A

D5740KKK

CM 32/250 C

12,5

9,2

3 ~ 400 690 V

20,1

70

D5741KKK

CM 32/250 B

15

11

3 ~ 400 690 V

24,2

82

D5742KKK

CM 32/250 A

20

15

3 ~ 400 690 V

30,1

93

250
4000

100 150 200 300 400 500 600

Discharge head
in meters

68

67

80,5 79,5

92

63,5 58,7 50,5

77

72,6 66,5

91,5 89.5 85.7

80

CM 40

SURFACE PUMPS
20
100
90
80

15

30
20

40
30

50

100

40

50

Q (US. GPM)
100

200

300

Q (IMP. GPM)

200

400
300

500
400

750
500

1000
750
300
250

250 A

70

200

60

250 B

50

150

200 A

40

200 B

30

100

160 A

75

160 B

20

125 A
50

H (m)

40

125 B

125 C

10

H (ft)

10
9
8
7
6
5

30

00

25

5
12

20

15

16

25

10

3
NPSH
(m)
2

NPSH
(ft)
5

1
4

5
75

CODE

100

9 10
150

MODEL

15
200

300

Motor
Power

Q (m3h) 30

20

Q (l/min) 500

VOLTAGE

HP

kW

Amp.
3 x 400 V

40

50
750

60

70 80 90 100

1000

L/1'
Q

m /h

1500

150
2000

200 300 400 500 600 700

12

24

30

36

42

CM 40/125 C

1,5

3 ~ 230 400 V

17,4 17,3 16,4 15,1 13,3

D5771KKK

CM 40/125 B

2,2

3 ~ 230 400 V

5,2

20,7 21,2 20,6 19,4 17,9

D5772KKK

CM 40/125 A

3 ~ 230 400 V

7,1

25,2 25,8 25,4 24,4 22,9 21,1

D5744KKK

CM 40/160 B

3 ~ 230 400 V

7,4

D5745KKK

CM 40/160 A

5,5

3 ~ 230 400 V

9,9

D5746KKK

CM 40/200 B

7,5

5,5

3 ~ 400 690 V

13,2

46,7 46,8 45,6 43,2 39,9 35,8

D5751KKK

CM 40/200 A

10

7,5

3 ~ 400 690 V

16,8

56,4 58

D5749KKK

CM 40/250 B

15

11

3 ~ 400 690 V

24,2

75,5 74,2 72,7 70,4 67,2 62,5

56

D5750KKK

CM 40/250 A

20

15

3 ~ 400 690 V

32

91,5 89,8 88,5 86,6

76

30
Discharge head
in meters

250
4000

PRICE
18

D5770KKK

10

200
3000

30

35,4 35,5

21

29

27,1 24,4

35

33,2 30,6 27,3

57,6

56

53

84

48,9 43,9

80,5

CM 50

SURFACE PUMPS
20
100
90
80

15

30
20

40
30

50

100

40

50

Q (US. GPM)
100

200

300

Q (IMP. GPM)

400

200

300

500
400

750
500

1000
750
300
250

250 A

70

200

60

250 B

50
40

250 C
200 A

30

200 B

150

100

160 A

200 C

20

75

160 B
125 A

H (m)

50
40

10

H (ft)

125 B

10
9
8
7
6
5

30

125 / 200 / 250

25
20
15

160

10

3
NPSH
(m)
2

NPSH
(ft)
5

1
4

5
75

CODE

100

9 10

15

150

200

300

Motor
Power

MODEL

HP

kW

Q (m3h) 30

20

Q (l/min) 500

VOLTAGE

Amp.
3 x 400 V

40

50

60

750

70 80 90 100

1000

L/1'

150

1500

2000

350 500 650 800 1000 1200

21

30

20

19,1 17,8 16,4

250
4000

PRICE
3

m /h

39

48

60

72

14

11,2

CM 50/125 B

3 ~ 230 400 V

7,4

19,9

D5774KKK

CM 50/125 A

5,5

3 ~ 230 400 V

9,9

24,5 24,8 24,2 23,1 21,8 19,6 16,5

D5753KKK

CM 50/160 B

7,5

5,5

3 ~ 400 690 V

11,6

30,2 30,5 29,8 28,5 26,7 23,3 19,1

D5755KKK

CM 50/160 A

10

7,5

3 ~ 400 690 V

15,8

36,3 37

D5775KKK

CM 50/200 C

12,5

9,2

3 ~ 400 690 V

18,5

D5756KKK

CM 50/200 B

15

11

3 ~ 400 690 V

21

D5757KKK

CM 50/200 A

20

15

3 ~ 400 690 V

27

58,5

57,5 55,7 53,2

D5758KKK

CM 50/250 C

20

15

3 ~ 400 690 V

32,5

71,5

70,3 68,3

D5759KKK

CM 50/250 B

25

18,5

3 ~ 400 690 V

41,5

78

77,4 75,3 72,8 68,2 62,2

D5760KKK

CM 50/250 A

30

22

3 ~ 400 690 V

51,5

90

88,8 86,9 84,5 80,5 75,2

Discharge head
in meters

D5773KKK

11

200
3000

36,6 35,6

47

44,5

52

50

42

34

31

26,9

38,5

33

24,5

47,7 44,7 39,5

66

32

49

42,8

61,5

55

CM 65

SURFACE PUMPS
20
100
90
80

15

30
20

40
30

50

100

40

50

Q (US. GPM)
100

200

300

Q (IMP. GPM)

400

200

500

300

750

400

1000

500

750
300
250

70
60

250 A

50

250 B

200

150

200 A

40

200 B
200 C

30

100

160 A
75

160 B

125 A

20

160 C
50

H (m)

125 B
40

10

H (ft)

10
9
8
7
6
5

125

30

250

25

160

20

200
15

4
10

3
NPSH
(m)
2

NPSH
(ft)
5

1
4

5
75

CODE

100

MODEL

9 10
150

15
200

20
300

Motor
Power

Q (m3h) 30
Q (l/min) 500

VOLTAGE

HP

kW

Amp.
3 x 400 V

40

50
750

60

70 80 90 100

1000

1500

150

200

2000

3000

L/1'

900 1200 1400 1800 2000 2200 2400

m3/h

54

PRICE

72

84

108 120 132

144

CM 65/125 B

7,5

5,5

3 ~ 400 690 V

12,3

19,8 20,1 18,8 17,7 14,3 12,3

D5777KKK

CM 65/125 A

10

7,5

3 ~ 400 690 V

15,9

24,2 24,1 23,4 22,3 19,4 17,5

D5761KKK

CM 65/160 C

12,5

3 ~ 400 690 V

19,5

30,4 30,8 29,6 28,3 24,6 22,1 19,3 16,0

D5762KKK

CM 65/160 B

15

11

3 ~ 400 690 V

22,5

34

34,2 33,3 32,1 28,8 26,7 24,1 21,1

D5763KKK

CM 65/160 A

20

15

3 ~ 400 690 V

30

39

40,4 39,7 38,9 36,2 34,3 32,2 29,8

D5764KKK

CM 65/200 C

20

15

3 ~ 400 690 V

32,5

43

44,8 43,7 42,3

D5765KKK

CM 65/200 B

25

18,5

3 ~ 400 690 V

41,5

47,5 49,5 48,5 47,3 43,5

D5766KKK

CM 65/200 A

30

22

3 ~ 400 690 V

51,5

56,5 56,7 55,7 54,7 51,6 49,6 47,1

D5778KKK

CM 65/250 B

40

30

3 ~ 400 690 V

63,5

81 79,5

76

73

65

D5779KKK

CM 65/250 A

50

37

3 ~ 400 690 V

74,5

90 89,5 86,5

84

76,5

Discharge head
in meters

D5776KKK

12

250
4000

38 35,3

41

60

15

32

38
44

54,5 48,5

72 66,5 60,5

CM 80

SURFACE PUMPS
20
100
90
80

15

30
20

40
30

50

100

40

50

Q (US. GPM)
100

200

300

Q (IMP. GPM)

200

400

500

300

400

750
500

1000
750
300
250

70
60

200 A

50

200 B

200

150
40

160 A
160 B
160 C

30

100

160 D

75

20
50

H (m)

40
H (ft)

10
10
9
8
7
6
5

30
25
20

160
200

15

4
10

3
NPSH
(m)
2

NPSH
(ft)
5

1
4

5
75

CODE

100

9 10
150

MODEL

15
200

20
300

Motor
Power
HP

kW

Q (m3h) 30

40

Q (l/min) 500

VOLTAGE

50

60

750

Amp.
3 x 400 V

70 80 90 100

1000

L/1'

1500

150
2000

250
4000

1200 1600 2000 2600 3000 3500


PRICE

Q
3

m /h

72

96

120 156 180 210

CM 80/160 D

15

11

3 ~ 400 690 V

20,8

24

25,3 23,9 21,8 17,9 14,6

D5781KKK

CM 80/160 C

20

15

3 ~ 400 690 V

25,8

29

29,3 28,1 25,9

D5782KKK

CM 80/160 B

25

18,5

3 ~ 400 690 V

35

D5783KKK

CM 80/160 A

30

22

3 ~ 400 690 V

42

D5786KKK

CM 80/200 B

40

30

3 ~ 400 690 V

D5787KKK

CM 80/200 A

50

37

3 ~ 400 690 V

Discharge head
in meters

D5780KKK

13

200
3000

33,5 33,9 32,7

31

22

18,7

27,7

25

20,3

37

37,9 36,9 35,5 32,4 29,9 25,8

63,5

49

50,6 49,8 47,7 45,5 41,6

74,5

58

59,6 58,6 56,4 54,3 50,8

JETINOX

SURFACE PUMPS
SELF-PRIMING STAINLESS STEEL
JET PUMPS
The JETINOX self-priming pumps combine the
functional benefits of centrifugal pumps and
the practical benefits of self-priming pumps.
The Venturi system the pumps are fitted with
guarantees optimum hydraulic efficiency and
considerable pressure capacity.
Design Features
- Pump casing in AISI 304 stainless steel
- Motor bracket in die-cast aluminium
- Technopolymer impeller with stainless steel
shim ring
- Monobloc technopolymer diffusor-Venturi
tube-nozzle assembly
- Stainless steel shaft
- Graphite mechanical seal with ceramic
counterface
- Technopolymer seal holder plate

48
40

Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use

32

70

/50

24

45

60/

/43

50

16

Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 8 m
with foot valve
- Maximum operating pressure 6 bar

8
Hm
Q

30
1,8

20
1,2

10
0,6

L / 1'
m3/ h

50
3

40
2,4

60
3,6

70
4,2

80
4,8

Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Washing systems, garden irrigation, fountains

Dimensions mm.

Model
A

Weight
E

DNA

DNM

kg

351

93

140

190

178

1" F

1" F

4,7

374

93

140

190

178

1" F

1" F

8,2

JETINOX 70/50

351

76

144

196

180

1"F

1" F

9,5

CODE

MODEL

Nominal Absorbed
Power
Power
HP

kW HP

VOLTAGE

Amp.

kW

N4176190

JETINOX 45/43 M 0,5 0,37 0,8 0,6 1 ~ 220240 V

N4176570

JETINOX 60/50 M 0,75 0,55 1,1 0,8 1 ~ 220240 V

12,5

N4176760

JETINOX 70/50 M 0,95 0,7 1,36 1,0 1 ~ 220240 V

4,5

16

L/1'

10

20

30

40

50

60

70

m /h

0,6

1,2

1,8

2,4

3,6

4,2

Discharge head
in meters

JETINOX 45/43
JETINOX 60/50

43

30

23

16

46

36

31

26

18

48

43

37

32

25

16

Steel base supplied separately

14

PRICE

JETINOX

SURFACE PUMPS
SELF-PRIMING STAINLESS STEEL
JET PUMPS
The JETINOX series self-priming pumps
combine the functional benefits of centrifugal
pumps and the practical benefits of self-priming
pumps.
The Venturi system the pumps are fitted with
guarantees optimum hydraulic efficiency and
considerable pressure capacity.
Design Features
- Pump casing in AISI 304 stainless steel
- Motor bracket in die-cast aluminium
- Technopolymer impeller with stainless steel
shim ring
- Monobloc technopolymer diffusor-Venturi
tube-nozzle assembly
- Stainless steel shaft
- Graphite mechanical seal with ceramic
counterface
- Stainless steel seal holder plate

60
50

Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use

40
90/50

30

90/43

20
10

Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 8 m
with foot valve
- Maximum operating pressure 6 bar

Hm
Q

45
2,7

30
1,8

15
0,9

L / 1'
m3/ h

75
4,5

60
3,6

90
5,4

105
6,3

Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Washing systems, garden irrigation, fountains

Dimensions mm.

Model

Weight

DNA

DNM

kg

JETINOX 90/43

397

98

168

220

235

1 1 /4 " M

1" F

11

JETINOX 90/50

430

98

168

260

235

1 1 /4 " M

1" F

13

MODEL

Nominal Absorbed
Power
Power
HP

kW HP

JETINOX 90/43 M

N4176500

JETINOX 90/50 M 1,2 0,9

Amp.

1,5 1 ~ 220240 V

L/1'

10

20

30

40

50

60

80

0,6

1,2

1,8

2,4

3,6

4,8

43

38

34

32

29

27

25

10

50

42

39

37

33

30

27

20

Q
m /h

kW

0,75 1,8 1,3 1 ~ 220240 V

N4176280

VOLTAGE

6,5

20

25

Discharge head
in meters

CODE

Steel base supplied separately

15

PRICE

NEW JET

SURFACE PUMPS
SELF-PRIMING CAST IRON
JET PUMPS
The NEWJET series self-priming pumps
combine the functional benefits of centrifugal
pumps and the practical benefits of self-priming
pumps.
The Venturi system the pumps are fitted with
guarantees optimum hydraulic efficiency and
considerable pressure capacity.
Design Features
- Cast iron pump casing
- Motor bracket in die-cast-aluminium
- Technopolymer impeller with stainless steel
shim ring
- Monobloc technopolymer diffusor-Venturi
tube-nozzle assembly
- Stainless steel shaft
- Graphite mechanical seal with ceramic
counterface

48
40

Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use

32
24

45

60/

/43

50

16

Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 8 m
with foot valve
- Maximum operating pressure 6 bar

8
Hm
Q

30
1,8

20
1,2

10
0,6

L / 1'
m3/ h

50
3

40
2,4

60
3,6

80
4,8

70
4,2

Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Washing systems, garden irrigation, fountains

Dimensions mm.

Model

Weight

DNA

DNM

kg

NEWJET 45/43

351

93

130

180

174

1"

1"

8,2

NEWJET 60/50

351

93

130

180

174

1"

1"

CODE

MODEL

Nominal
Power

Absorbed
Power

HP

kW

HP

kW

L/1'

VOLTAGE

Amp.

F.

N4176050

NEWJET 45/43 M

0,5

0,37

0,8

0,6

1 ~ 220 240 V

N4176580

NEWJET 60/50 M

0,75

0,55

1,1

0,8

1 ~ 220 240 V

12,5

16

10

20

30

40

50

60

0,6

1,2

1,8

2,4

3,6

43

30

23

16

46

36

31

26

18

Q
3

m /h
Discharge
head
in meters

PRICE

SURFACE PUMPS
SELF-PRIMING CAST IRON
JET PUMPS
The JET series self-priming pumps combine
the functional benefits of centrifugal pumps and
the practical benefits of self-priming pumps.
The Venturi system the pumps are fitted with
guarantees optimum hydraulic efficiency and
considerable pressure capacity.
Design Features
- Cast iron pump casing
- Cast iron motor bracket
- Technopolymer impeller, Venturi tube and
nozzle
- Diffusor, with stainless steel shim ring
- Stainless steel shaft
- Graphite mechanical seal with ceramic
counterface

50

Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use

40
30

100

00

60

20

10

Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 8 m
with foot valve
- Maximum operating pressure 6 bar

Hm
Q

30
1,8

20
1,2

10
0,6

L / 1'
m3/ h

50
3

40
2,4

60
3,6

80
4,8

70
4,2

Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Washing systems, garden irrigation, fountains

Dimensions mm.

Model

Weight

DNA

DNM

kg

JET 600

400

147

160

190

182

1"

1"

13,7

JET 800

400

147

160

190

182

1"

1"

14,2

JET 1000

425

147

160

190

182

1"

1"

16,8

MODEL

Nominal
Power

Absorbed
Power

HP

kW

HP

kW

VOLTAGE

Amp.

F.

L/1'

JET 600 M
JET 600 T

0,8

0,6

0,9

0,7

1 ~ 220 240 V
3 ~ 230 400 V

3,2
1,9-1,1

N4176550
N4176560

JET 800 M
JET 800 T

0,75

1,3

1 ~ 220 240 V
3 ~ 230 400 V

4,5
3,6-2,1

12,5

N4173010
N4173020

JET 1000 M
JET 1000 T

1,36

1,5

1,1

1 ~ 220 240 V
3 ~ 230 400 V

5
3,8-2,2

16

17

20

30

40

50

60

70

0,3

1,2

1,8

2,4

3,6

4,2

43

40

30

24

17

48

46

39

33

27

50

48

41

37

32

28

18

PRICE
3

m /h

N4171010
N4171020

Discharge head
in meters

CODE

JET

SURFACE PUMPS
SELF-PRIMING CAST IRON
JET PUMPS
The JET series self-priming pumps combine
the functional benefits of centrifugal pumps and
the practical benefits of self-priming pumps.
The Venturi system the pumps are fitted with
guarantees optimum hydraulic efficiency and
considerable pressure capacity.
Design Features
- Cast iron pump casing
- Cast iron motor bracket
- Pressed brass alloy impeller
- Technopolymer diffusor, Venturi tube and
nozzle
- Stainless steel shaft
- Graphite mechanical seal with ceramic
counterface

80
70

Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use

100
/68

60

100
/80

50

160/60
160/52

100/5
0

40
30
20

Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 8 m
with foot valve
- Maximum operating pressure 10 bar

10
Hm
Q

20
1,2

L / 1'
m3/ h

60
3,6

40
2,4

100
6

80
4,8

120
7,2

140
8,4

160
9,6

Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Washing systems, garden irrigation, fountains

Dimensions mm.

Model
A

Weight

H2

H1

DNA

DNM

kg

1/2"

JET 100/50

180

157

500

220

180

235

170

227

1"

27

JET 100/68 - 160/52

180

157

500

220

180

235

170

227

1 1/2"

1"

29

227

1"

31

CODE

MODEL

157

180
Nominal
Power

500

Absorbed
Power

HP

kW

HP

kW

220

180

235

170

L/1'

VOLTAGE

Amp.

F.

N4175010
N4175020

JET 100/50 M
JET 100/50 T

1,5

1,1

2,2

1,6

1 ~ 230 V
3 ~ 230 400 V

7,4
5-2,5

31,5

N4175030
N4175040

JET 100/68 M
JET 100/68 T

1,5

2,7

1 ~ 230 V
3 ~ 230 400 V

10,5
7,5-4,3

31,5

N4175050

JET 100/80 T

2,2

3,4

2,5

3 ~ 230 400 V

8,2-4,8

N4175080
N4175090

JET 160/52 M
JET 160/52 T

1,5

2,7

1 ~ 230 V
3 ~ 230 400 V

10,5
7,5-4,3

N4175100

JET 160/60 T

2,2

3,4

2,5

3 ~ 230 400 V

9,2-5,3

18

31,5

100 120 140

20

40

60

80

0,3

1,2

2,4

3,6

4,8

50

45

40

35

32

27

65

60,5

55

48

43

35

77

70,5

65

58

52

45

52

49,5

46

43

39,5

60

58

54,5

51

47

Q
3

m /h

Discharge head
in meters

JET 100/80 - 160/60

1/2"

PRICE
7,2

8,4

36

33,5

30

44

40

38

AP

SURFACE PUMPS
DEEP SUCTION SELF-PRIMING
PUMPS COMPLETE WITH EJECTOR
The JET AP 800, AP 1000 pumps are suitable for
deep suction from wells with a minimum diameter
of 4" using a recirculation system.
Design Features
- Cast iron pump casing AP 800/AP 1000
- Cast iron motor bracket
- Technopolymer diffusor, impeller, Venturi tube and
nozzle AP 800/AP 1000
- Stainless steel shaft
- Graphite mechanical seal with ceramic counterface
Cast Iron Ejector
- supplied as standard N30 (on request N20)
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Three phase power supply with external protection
provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height with foot
valve: AP 800 = 30m AP 1000 = 35m
- Maximum operating pressure 6 bar
Applications
- Pumping and distribution
- Booster systems

Dimensions mm.

Model

Weight

DNA

AP 800

340

147

182

92

AP 1000

365

147

182

92

Nominal
Power

Absorbed
Power

CODE

MODEL

HP

kW

HP

VOLTAGE

Amp.

F.

kW

DNM

DNME

kg

43

1 /4 "

1"

1"

13,2

43

1 1 /4 "

1"

1"

15,8

Max
Suction

Ejector Suction
Type
m

L/1' 10 15 20 25 30 40 50
Q
m3/h 0,6 0,9 1,2 1,5 1,8 2,4 3

15

35

22

20

21

10

11

25

22

16

11

15

10

49

33

22

31

19

10

25

27

22

16

11

30

19

16

10

35

14

10

N20
AP 800 M

0,75

1,3

1 ~ 220 240 V

4,5

12,5

30
N30
30
15
N20
20

N4173030

AP 1000 M

1,36

1,5

1,1

1 ~ 220 240 V

16

35
N30

19

Discharge head
in meters

N4176630

11

PRICE

MCX

SURFACE PUMPS
MULTISTAGE
CENTRIFUGAL PUMPS
The MCX series horizontal multistage centrifugal
p u m p s o ff e r t h e f o l l o w i n g b e n e f i t s :
- High hydraulic pressure and flow rate
performance
- Minimum electric energy consumption
- Extremely silent operation
Design Features
- Stainless steel pump casing AISI304
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel
shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic
counterface

60

Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use

50

Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 6m
with foot valve
- Maximum operating pressure 7 bar

10

80 / 6

40

80/4

30

80/36

20

Hm
Q

10
0,6

L / 1'
m3/ h

30
1,8

20
1,2

50
3

40
2,4

60
3,6

80
4,8

70
4,2

Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Firefighting systems
- Washing systems, irrigation

Dimensions mm.

Model

Weight

DNA

DNM

Kg

MCX 80/36

90

296

99

190

174

1"

1"

MCX 80/48

90

318

99

190

174

1"

1"

MCX 80/60

90

360

99

195

174

1"

1"

MODEL

Absorbed
Power

VOLTAGE

Amp.

F.

L/1'

kW

HP

kW

N4201180-B MCX 80/36 M


N4201240-B MCX 80/36 T

0,6

0,45

0,8

0,6

1 ~ 230 V
3 ~ 230 400 V

2,9
2-1,2

12,5

N4201190-B MCX 80/48 M


N4201250-B MCX 80/48 T

0,75

0,55

1,1

0,8

1 ~ 230 V
3 ~ 230 400 V

4
2,6-1,5

12,5

N4201200-B MCX 80/60 M


N4201260-B MCX 80/60 T

0,75

1,3

1 ~ 230 V
3 ~ 230 400 V

4,8
2,9-1,7

16

Steel base supplied separately

20

20

40

60

80

100

1,2

2,4

3,6

4,8

35

28

21

13

0,5

45

36

28

17

57

50

40

27

PRICE
3

m /h

HP

Discharge head
in meters

CODE

Nominal
Power

SURFACE PUMPS
MULTISTAGE
CENTRIFUGAL PUMPS
The MCX series horizontal multistage centrifugal
p u m p s o ff e r t h e f o l l o w i n g b e n e f i t s :
- High hydraulic pressure and flow rate
performance
- Minimum electrical energy consumption
- Extremely silent operation
Design Features
- Stainless steel pump casing AISI 304
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel
shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic
counterface

60

Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use

50

1 20

40

12 0

30

120/3

/6 0

/4 8

20

Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 6 m
with foot valve
- Maximum operating pressure 7 bar

10
Hm
Q

20
1,2

L / 1'
m3/ h

60
3,6

40
2,4

80
4,8

100
6

120
7,2

Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Firefighting systems
- Washing systems, irrigation

Dimensions mm.

Model

Weight

DNA

DNM

Kg

MCX 120/36

90

316

99

195

174

1"

1"

MCX 120/48

90

338

99

195

174

1"

1"

MCX 120/60

90

360

99

195

174

1"

1"

10

MODEL

Absorbed
Power

VOLTAGE

Amp.

F.

L/1'

kW

HP

kW

N4201210-B MCX 120/36 M


N4201270-B MCX 120/36 T

0,75

1,1

0,8

1 ~ 230 V
3 ~ 230 400 V

3,5
2,9-1,7

12,5

N4201220-B MCX 120/48 M


N4201280-B MCX 120/48 T

0,75

1,5

1,1

1 ~ 230 V
3 ~ 230 400 V

4,6
3,6-2,1

16

N4201230-B MCX 120/60 M


N4201290-B MCX 120/60 T

1,2

0,9

1,7

1,25

1 ~ 230 V
3 ~ 230 400 V

5,8
3,5-2

20

Steel base supplied separately

21

20

40

60

80

100

1,2

2,4

3,6

4,8

36

33

28

22

14

48

42

37

27

18

60

55

48

36

26

10

PRICE
3

m /h

HP

Discharge head
in meters

CODE

Nominal
Power

MCX

SURFACE PUMPS
MULTISTAGE
CENTRIFUGAL PUMPS
The MCX series horizontal multistage centrifugal
p u m p s o ff e r t h e f o l l o w i n g b e n e f i t s :
- High hydraulic pressure and flow rate
performance
- Minimum electrical energy consumption
- Extremely silent operation
Design Features
- Stainless steel pump casing AISI 304
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel
shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic
counterface

BA010042/01.06.01

BA000062/14.06.00

BA000011/29.03.99

70

Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use

60

2 0 0/
65
2 0 0/ 5
2

50
40

2 0 0 /4 0

30
20

Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 6 m
with foot valve
- Maximum operating pressure 7 bar

10
Hm
Q

20 30
1,2 1,8

L / 1'
m3/ h

40 60
2,4 3,6

80 100 120 140 160 180 200


4,8 6,0 7,2 8,4 9,6 10,8 12

Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Firefighting systems
- Washing systems, irrigation

Dimensions mm.

Model
A

Weight

DNA

DNM

kg

1 /4 "

14

MCX 200/40

105

400

141

235

205

MCX 200/52

105

430

141

235

205

1 1/4"

1 1 /4 "

16

205

1 1/4"

1 1 /4 "

18

CODE

105

MODEL

Nominal
Power

460
Absorbed
Power

HP

kW

HP

kW

141

VOLTAGE

235

Amp.

F.

L/1'

MCX 200/40 M
MCX 200/40 T

1,5

1,1

1,5

1 ~ 230 V
3 ~ 230 400 V

7
3,6-2,1

20

N4201380-B
N4201390-B

MCX 200/52 M
MCX 200/52 T

1,8

1,3

2,5

1,8

1 ~ 230 V
3 ~ 230 400 V

8,5
5-2,9

25

N4201400-B

MCX 200/65 T

1,9

1,4

2,7

3 ~ 230 400 V

6-3,5

Steel base supplied separately

22

20

40

80

120 160 200

1,2

2,4

4,8

7,2

9,6

38

35

32

26

19

11

49

47

44

38

29

18

62

59

55

47

36

22

PRICE
3

m /h

N4201360-B
N4201370-B

Discharge head
in meters

MCX 200/65

1/4"

12

SURFACE PUMPS
MULTISTAGE
CENTRIFUGAL PUMPS
The DHR series horizontal multistage centrifugal
p u m p s o ff e r t h e f o l l o w i n g b e n e f i t s :
- High hydraulic pressure and flow rate
performance
- Minimum electrical energy consumption
- Extremely silent operation
Design Features
- Pump casing built in stages in AISI 304
stainless steel
- Motor bracket in GG20 cast iron
- Suction flange in GG20 cast iron
- Impellers and diffusors in AISI 304 stainless
steel
- Shaft in AISI 316 stainless steel
- NBR rubber O ring
- Mechanical seal with graphite/ceramic
counterfaces
Motor
- Enclosed, externally ventilated
- Level of protection IP 54
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- M a x i m u m l i q u i d t e m p e r a t u re 9 0 C
- Maximum recommended suction height 6 m
with foot valve (with max. liquid temp. at 50C)
- Maximum operating pressure 6 bar
Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Washing systems, garden irrigation, fountains

Nominal
Power

Absorbed
Power

HP

kW

HP

VOLTAGE

Amp.

F.

m /h

DHR 23 M
DHR 23 T

0,5
0,5

0,37
0,37

0,65
0,62

2,4
1,75 - 1

14

E0502105
E0501005

DHR 25 M
DHR 25 T

0,75
0,75

0,55
0,55

3,8
0,98 0,725
1 ~ 230 V
0,95 0,7 3 ~ 230 400 V 2,45 - 1,4

16

MODEL

Nominal
Power

0,48
1 ~ 230 V
0,46 3 ~ 230 400 V

Absorbed
Power

HP

kW

HP

VOLTAGE

Amp.

F.

E1502102
E1501002

DHR 42 M
DHR 42 T

0,5
0,5

0,37
0,37

0,73
0,7

1 ~ 230 V
0,54
0,52 3 ~ 230 400 V

2,6
1,9 - 1,1

14

E1502103
E1501003

DHR 43 M
DHR 43 T

0,75
0,75

0,55
0,55

1
0,99

0,75
1 ~ 230 V
0,73 3 ~ 230 400 V

3,9
2,6 - 1,5

16

E1502104
E1501004

DHR 44 M
DHR 44 T

1
1

0,75
0,75

1,33
1,25

0,98
1 ~ 230 V
5
0,92 3 ~ 230 400 V 2,95 - 1,7

20

E1502105
E1501005

DHR 45 M
DHR 45 T

1,5
1,5

1,1
1,1

1,7
1,61

6,3
1,25
1 ~ 230 V
1,19 3 ~ 230 400 V 4,2 - 2,4

32

E1502106
E1501006

DHR 46 M
DHR 46 T

1,5
1,5

1,1
1,1

1,97
1,87

1,45
1 ~ 230 V
1,38 3 ~ 230 400 V

7,4
4,5 - 2,6

32

23

20

30

40

50

0,6

1,2

1,8

2,4

28

26

23

19

15

44

42

37

32

25

L/1'

40

60

80

100 120

2,4

3,6

4,8

7,2

16

14

12

23

20

17

14

10

30

27

23

18

13

39

35

30

24

17

47

42

35

28

20

Q
3

m /h

kW

10

PRICE
3

kW

E0502103
E0501003

CODE

L/1'
Q

Discharge head
in meters

MODEL

Discharge head
in meters

CODE

PRICE

DHR
DHR 42 /43 / 44
45 / 46
50 Hz

DHR 23 /25
50 Hz

Weight

Dimensions mm.

Model

DNA

DNM

L1

L2

L3

L4

DHR 23

368

120

109

140

1"

1"

11,3

DHR 25

422

168

157

193

1"

1"

12,6

110

1/4"

1"

11,3

DHR 42

342

93

85

kg

DHR 43

370

120

110

137

1 1/4"

1"

12,3

DHR 44

396

144

133

165

1 1/4"

1"

13,6

1"

15,8

1"

17,2

DHR 45

445

173

162

190

1 1/4"

DHR 46

470

200

189

217

1 1/4"

24

SURFACE PUMPS
MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The DHI series horizontal multistage centrifugal pumps
offer the following benefits:
- High hydraulic pressure and flow rate performance
- Minimum electrical energy consumption
- Extremely silent operation
Design Features
- Pump casing in AISI 316 stainless steel
- Aluminium motor coupling bracket
- Seal holder plate in AISI 316 stainless steel
- Impellers and diffusors in AISI 316 stainless steel
- Shaft in AISI 316 stainless steel
- EPDM rubber O ring
- Mechanical seal with graphite/ceramic counterfaces
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Three phase power supply with external protection
provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Types of pumped liquid: clear, non-explosive with
no suspended solids or abrasive material
- Special liquids such as: softened demineralised
water, washing system solutions, oils, non-aggressive
chemical compound fluids
- Maximum liquid temperature 90C
- Maximum recommended suction height 6 m with
foot valve (with max. liquid temp. at 50C)
- Maximum operating pressure 6 bar
Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent basis
- Booster systems
- Washing systems, garden irrigation, fountains
- Condensate conveyance
- Food and wine industries
- As a component of industrial machinery

Nominal
Power

Absorbed
Power

HP

kW

HP

kW

VOLTAGE

Amp.

F.

DHI 24 M
DHI 24 T

0,75

0,55

1,00

0,75

1 ~ 230 V
3 ~ 400 V

3,4
1,4

16

N4221010
N4221080

DHI 26 M
DHI 26 T

1,00

0,75

1,30

0,95

1 ~ 230 V
3 ~ 400 V

4,3
2,0

20

N4221020
N4221090

DHI 27 M
DHI 27 T

1,25

0,9

1,65

1,20

1 ~ 230 V
3 ~ 400 V

5,3
2,4

32

VOLTAGE

Amp.

F.

MODEL

Nominal
Power
HP

kW

Absorbed
Power
HP

kW

m /h

N4221000
N4221070

CODE

L/1'

DHI 43 M
DHI 43 T

0,75

0,55 1,00

0,75

1 ~ 230 V
3 ~ 400 V

3,5
1,6

16

N4221040
N4221110

DHI 44 M
DHI 44 T

1,00

0,75

1,36

1,00

1 ~ 230 V
3 ~ 400 V

4,6
2,0

20

N4221050
N4221060

DHI 45 M
DHI 45 T

1,25

0,9

1,70

1,25

1 ~ 230 V
3 ~ 230 400 V

5,9
2,5

25

Steel base supplied separately

25

20

30

40

50

60

0,6

1,2

1,8

2,4

3,6

35

32

28

25

20

16

52

46

40

34

27

19

63

57

50

43

35

26

L/1'

40

60

80

2,4

3,6

4,8

7,2

24

22

18

16

12

33

31

27

22

16

42

36

33

27

18

100 120

Q
3

m /h

N4221030
N4221100

10

Discharge head
in meters

MODEL

Discharge head
in meters

CODE

PRICE

PRICE

DHI

DHI 24 / 26 / 27
50Hz

DHI 43 / 44 / 45
50 Hz

Weight

Dimensions mm.

Model
A

DNA

DNM

Kg

11/4

11,3
12,6

DHI 24

105

400

141

235

205

11/4

DHI 26

105

430

141

235

205

11/4

11/4
11/4

11,3

DHI 27

105

460

141

235

205

11/4

DHI 43

105

400

141

235

205

11/4

11/4

12,3

DHI 44

105

430

141

235

205

11/4

11/4

13,6

DHI 45

105

460

141

235

205

11/4

11/4

15,8

26

SURFACE PUMPS
SELF-PRIMING MULTISTAGE
CENTRIFUGAL PUMPS
The MAX series horizontal multistage centrifugal
pumps offer the following benefits:
- High hydraulic pressure and flow rate
performance
- Minimum electrical energy consumption
- Extremely silent operation
Design Features
- Stainless steel pump casing AISI 304
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel
shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic
counterface
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 7 m
with foot valve
- Maximum operating pressure 7 bar

60
50

80 / 6

40

80/4

30
20
10
Hm
Q

L / 1'
m3/ h

10
0,6

30
1,8

20
1,2

50
3

40
2,4

60
3,6

80
4,8

70
4,2

Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Firefighting systems
- Washing systems, irrigation
Water recycling in the pump casing only takes
place during the priming stage, after which the
special valve closes recirculation achieving
maximum flow rate.

Dimensions mm.

Model

Weight

DNA

DNM

kg

MAX 80/48

129

370

99

182

176

1"

1"

MAX 80/60

129

392

99

182

176

1"

1"

MODEL

Nominal
Power

Absorbed
Power

VOLTAGE

Amp.

F.

L/1'

kW

HP

kW

N4501030-B MAX 80/48 M


N4501070-B MAX 80/48 T

0,75

0,55

1,1

0,8

1 ~ 230 V
3 ~ 230 400 V

4
2,6-1,5

12,5

N4501040-B MAX 80/60 M


N4501080-B MAX 80/60 T

0,75

1,3

1 ~ 230 V
3 ~ 230 400 V

4,8
2,9-1,7

16

Steel base supplied separately

27

20

40

60

80

1,2

2,4

3,6

4,8

45

36

28

17

57

50

40

27

PRICE
3

m /h

HP

Discharge head
in meters

CODE

MAX
SELF-PRIMING MULTISTAGE
CENTRIFUGAL PUMPS
The MAX series horizontal multistage centrifugal
p u m p s o ff e r t h e f o l l o w i n g b e n e f i t s :
- High hydraulic pressure and flow rate
performance
- Minimum electrical energy consumption
- Extremely silent operation
Design Features
- Stainless steel pump casing AISI 304
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel
shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic
counterface

60

Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use

50

1 20

40

12 0

/6 0

/4 8

30
20

Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 7 m
with foot valve
- Maximum operating pressure 7 bar

10
Hm
Q

20
1,2

L / 1'
m3/ h

Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Firefighting systems
- Washing systems, irrigation

60
3,6

40
2,4

100
6

80
4,8

120
7,2

Water recycling in the pump casing only takes


place during the priming stage, after which the
special valve closes recirculation achieving
maximum flow rate.

Weight

Dimensions mm.

Model
A

DNA

DNM

kg.

MAX 120/48

129

393

99

192

176

1"

1"

10

MAX 120/60

129

415

99

192

176

1"

1"

11

MODEL

Absorbed
Power

VOLTAGE

Amp.

F.

HP

kW

HP

kW

N4501050-B MAX 120/48 M


N4501090-B MAX 120/48 T

0,75

1,5

1,1

1 ~ 230 V
3 ~ 230 400 V

4,6
3,6-2,1

16

N4501060-B MAX 120/60 M


N4501100-B MAX 120/60 T

1,2

0,9

1,7

1,25

1 ~ 230 V
3 ~ 230 400 V

5,8
3,5-2

20

Steel base supplied separately

28

L/1'

20

40

60

80

100

m3/h

1,2

2,4

3,6

4,8

48

42

37

27

18

60

55

48

36

26

10

PRICE

Discharge head
in meters

CODE

Nominal
Power

MULTINOX-A

SURFACE PUMPS
SELF-PRIMING MULTISTAGE
CENTRIFUGAL PUMPS
The horizontal multistage centrifugal self-priming
MULTINOX-A pumps are suitable for developing a
considerable pressure and flow rate with extremely
silent operation and with minimum electrical energy
consumption.
Design Features
- Stainless steel outer liner
- Cast iron motor bracket
- Cast iron suction flange
- Technopolymer impellers with
stainless steel shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic counterface
- Special patented brass valve for closure during the
priming stage
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Three phase power supply with external protection
provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 8 m with
foot valve
- Maximum operating pressure 9 bar

RIMING

SELF-P

80
70

200

60

/ 80

20 0/
65
200/5
2
2 0 0 /4 0

50
40
30
20
10
Hm
Q

80
4,8

40
2,4

L / 1'
m3/ h

120
7,2

160
9,6

200
12

Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent basis
- Booster systems
- Washing systems, garden irrigation, fountains
Water recycling in the pump casing only takes place
during the priming stage, after which the special valve
closes recirculation achieving maximum flow rate.
Weight

Dimensions mm.

Model
A

DNA

DNM

kg

MULTINOX 200/40

441

200

188

155

170

1 1 /4 "

1 1/4"

19

MULTINOX 200/52

469

200

215

155

170

1 1 /4 "

1 1/4"

21

MULTINOX 200/65

497

200

243

155

170

1 1 /4 "

1 1/4"

23

MULTINOX 200/80

525

200

270

155

170

1 1 /4 "

1 1/4"

25

MODEL

Nominal Absorbed
Power
Power

VOLTAGE

Amp.

F. Q

HP kW HP kW

N418A010 -B MULTINOX-A 200/40 M

1,5 1,1

1,5

N418A020 -B MULTINOX-A 200/40 T


N418A030 -B MULTINOX-A 200/52 M

1,8 1,3 2,5 1,8

N418A040 -B MULTINOX-A 200/52 T


N418A050 -B MULTINOX-A 200/65 T 1,9 1,4 2,7

N418A060 -B MULTINOX-A 200/80 T 2,5 1,8 3,5 2,6

L/1'

20

40

80

120

160

m3/h

1,2

2,4

4,8

7,2

9,6

38

37

32

24

12

50

49

42

32

18

63

60

52

40

24

77

73

62

48

27

20

1 ~ 220240 V

3 ~ 230400 V

3,6-2,1

1 ~ 220240 V

8,5

3 ~ 230400 V

5-2,9

3 ~ 230400 V

6-3,5

3 ~ 230400 V

8-4,6

29

25

Discharge head
in meters

CODE

PRICE

MULTINOX-VE

SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The MULTINOX-VE vertical multistage
centrifugal pumps are especially suitable for
the manufacture of pumping assemblies, above
all in cases where a high level of efficiency and
silence is required with reduced overall floor
dimensions.
Design Features
- Stainless steel outer liner
- Cast iron motor bracket
- Cast iron suction flange
- Technopolymer impellers with stainless steel
shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic
counterface

100
90
80
70
60
50
40
30
20
10

Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 6 m
with foot valve
- Maximum operating pressure 9 bar

200/9
0
200/8
0
200/65
200/52

200/40

Hm
Q

80
4,8

40
2,4

L / 1'
m3/ h

120
7,2

160
9,6

200
12

Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Firefighting systems
- Washing systems, garden irrigation, fountains

Dimensions mm.

Model

CODE

MODEL

A
438
466
504
525
555

B
115
115
115
115
115

Nominal Absorbed
Power
Power

C
37
37
37
37
37

VOLTAGE

D
143
174
203
230
257

Amp.

F. Q

HP kW HP kW

N4194010 -B
N4194020 -B
N4194030 -B
N4194040 -B

MULTINOX 200/40 M VE
MULTINOX 200/40 T VE
MULTINOX 200/52 M VE
MULTINOX 200/52 T VE

1,5 1,1

1,5

1,8 1,3 2,5 1,8

1 ~ 220240 V
3 ~ 230400 V
1 ~ 220240 V
3 ~ 230400 V

7
3,6-2,1
8,5
5-2,9

3 ~ 230400 V

6-3,5

N4194050 -B MULTINOX 200/65 T VE

1,9 1,4 2,7

N4194060 -B MULTINOX 200/80 T VE

2,5 1,8 3,5 2,6

3 ~ 230400 V

8-4,6

N4194070 -B MULTINOX 200/90 T VE

2,6 1,9 3,7 2,7

3 ~ 230400 V

9-5,2

30

E
204
204
204
204
204

DNA
1 1/4"
1 1/4"
1 1/4"
1 1/4"
1 1 /4 "

DNM
1 1/4"
1 1/4"
1 1/4"
1 1/4"
1 1/4"

L/1'

20

40

80

120

160

m3/h

1,2

2,4

4,8

7,2

9,6

38

37

32

24

12

50

49

42

32

18

63

60

52

40

24

77

73

62

48

27

83

78

67

54

33

20
25
Discharge head
in meters

MULTINOX 200/40 VE
MULTINOX 200/52 VE
MULTINOX 200/65 VE
MULTINOX 200/80 VE
MULTINOX 200/90 VE

Weight
kg
19
21
23
25
27
PRICE

SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 2Bs are vertical multistage centrifugal pumps with "in line" suction
and delivery points directly connected to an electric motor. They are not
self-priming.
Design Features
- Impellers, diffusors, intermediate chambers and outer liner in AISI 304
stainless steel, shaft in AISI 431 stainless steel
- Base and head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- All the version "A" VLR are complete with 1" oval gas counterflanges
- For the version "F" VLR , round DN32 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure:
Oval flanges
: 16 bar
DIN flanges
: 25 bar (maximum pumped liquid temperature 40 C)
: 21 bar (maximum pumped liquid temperature 120 C)
- Maximum inlet pressure:
VLR 2B-30/2
=
6 bar
VLR 2B-30 - VLR 2B-110 = 10 bar
VLR 2B-130 - VLR 2B-260 = 15 bar
- Minimum suction head:
Please refer to NPSH plus a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer
CODE

Motor
Power

MODEL

VOLTAGE

HP

kW

Amp.

F.

L/1'

10

20

30

40

50

0,6

1,2

1,8

2,4

19

18

17

14

11

29

27

25

21

17

37

35

32

29

23

47

43

40

35

28

56

51

48

42

33

65

60

55

49

39

84

78

70

62

50

100

93

84

74

60

120 112 102

89

71

138 129 116

99

81

166 155 141 122

99

PRICE
3

m /h

VLR 2B - 30/2 A M
VLR 2B - 30/2 A T

0,5

0,37

1 ~ 230 V
3 ~ 230 400 V

2,7
1-0,6

14

E2302103
E2301003

VLR 2B - 30 A M
VLR 2B - 30 A T

0,5

0,37

1 ~ 230 V
3 ~ 230 400 V

2,7
1,4-0,8

14

E2302104
E2301004

VLR 2B - 40 A M
VLR 2B - 40 A T

0,75

0,55

1 ~ 230 V
3 ~ 230 400 V

4
1,8-1

16

E2302105
E2301005

VLR 2B - 50 A M
VLR 2B - 50 A T

0,75

0,55

1 ~ 230 V
3 ~ 230 400 V

4
2,3-1,3

16

E2302106
E2301006

VLR 2B - 60 A M
VLR 2B - 60 A T

0,75

1 ~ 230 V
3 ~ 230 400 V

5,2
2,7-1,5

25

E2302107
E2301007

VLR 2B - 70 A M
VLR 2B - 70 A T

0,75

1 ~ 230 V
3 ~ 230 400 V

5,2
3-1,7

25

E2302109
E2301009

VLR 2B - 90 A M
VLR 2B - 90 A T

1,5

1,1

1 ~ 230 V
3 ~ 230 400 V

8
3,6-2,1

35

E2302111
E2301011

VLR 2B - 110 A M
VLR 2B - 110 A T

1,5

1,1

1 ~ 230 V
3 ~ 230 400 V

8
4,3-2,5

35

E2302113
E2301013

VLR 2B - 130 A M
VLR 2B - 130 A T

1,5

1 ~ 230 V
3 ~ 230 400 V

12
5-2,9

45

E2302115
E2301015

VLR 2B - 150 A M
VLR 2B - 150 A T

1,5

1 ~ 230 V
3 ~ 230 400 V

12
5,7-3,3

45

E2331018

VLR 2B - 180 F T

2,2

3 ~ 230 400 V

7,2-4,1

E2331022

VLR 2B - 220 F T

2,2

3 ~ 230 400 V

8,7-5

199 185 168 145 118

E2331026

VLR 2B - 260 F T

3 ~ 230 400 V

11,4-6,6

232 220 200 173 141

31

Discharge head
in meters

E2302102
E2301002

VLR 2B
Version with oval flanges
VLR 2B 30/2 - VLR 2B 150
H

B1

50

A1

L1

3/4"

22

60
100
156
160

22

65
3/8"

20

M 10x40

1"gas

104
180
210

13,5

Version with round flanges


PN10 DIN 2534/ISO 7005-2

H
D

B1

- Power ( Kw ) and efficiency (

%) refer to one stage

A2

L2

3/4"

3/8"

3/8"

75

A1 1

60
100
156
250
3/8"

20

32
78
100
140

n4 holes 18

104
180
210

13,5
4 holes

Net Weight
(kg)

Dimensions (mm)
Model

VLR 2B - 30/2
VLR 2B - 30
VLR 2B - 40
VLR 2B - 50
VLR 2B - 60
VLR 2B - 70
VLR 2B - 90
VLR 2B - 110
VLR 2B - 130
VLR 2B - 150
VLR 2B - 180
VLR 2B - 220
VLR 2B - 260

238
238
256
274
296
314
350
386
441
477
-

32

B1

213
213
213
213
237
237
237
237
265
265
265
265
315

L1 1

451
451
469
487
533
551
587
623
706
742
-

A2 2

556
628
704

L2 2

821
893
1019

142
142
142
142
160
160
160
160
185
185
185
185
200

109
109
109
109
131
131
131
131
130
130
130
130
140

20
21
23
25
26
33
34
36
37
43
-

49
61
63

SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 4s are vertical multistage centrifugal pumps with "in line" suction
and delivery points directly connected to an electric motor. They are not
self-priming.
Design Features
- Impellers, diffusors, intermediate chambers and outer liner in AISI 304
stainless steel, shaft in AISI 431 stainless steel
- Base and head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- All the version "A" VLR are complete with 11/4" oval gas counterflanges
- For the version "F" VLR, round DN32 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure:
Oval flanges
: 16 bar
DIN flanges
: 25 bar (maximum pumped liquid temperature 40 C)
: 21 bar (maximum pumped liquid temperature 120 C)
- Maximum inlet pressure:
VLR 4- 20
= 6 bar
VLR 4- 30 - VLR 4-100 = 10 bar
VLR 4-120 - VLR 4-260 = 15 bar
- Minimum suction head:
Please refer to NPSH plus a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer
CODE

Motor
Power

MODEL

HP

kW

VOLTAGE

F.

Amp.

L/1'

40

60

80

100 120

2,4

3,6

4,8

7,2

19

17

15

13

28

25

22

19

13

36

33

29

25

18

44

42

37

31

23

53

50

44

38

27

61

58

51

44

32

71

67

59

50

37

90

82

72

61

46

99

Q
3

m /h

VLR 4 - 20 A M
VLR 4 - 20 A T

0,5

0,37

1 ~ 230 V
3 ~ 230 400 V

2,7
1,73-1

14

E3502103
E3501003

VLR 4 - 30 A M
VLR 4 - 30 A T

0,75

0,55

1 ~ 230 V
3 ~ 230 400 V

4
2,5-1,45

16

E3502104
E3501004

VLR 4 - 40 A M
VLR 4 - 40 A T

0,75

1 ~ 230 V
3 ~ 230 400 V

5,2
3,3-1,9

25

E3502105
E3501005

VLR 4 - 50 A M
VLR 4 - 50 A T

1,5

1,1

1 ~ 230 V
3 ~ 230 400 V

8
4,3-2,5

35

E3502106
E3501006

VLR 4 - 60 A M
VLR 4 - 60 A T

1,5

1,1

1 ~ 230 V
3 ~ 230 400 V

8
4,3-2,5

35

E3502107
E3501007

VLR 4 - 80/7 A M
VLR 4 - 80/7 A T

1,5

1 ~ 230 V
3 ~ 230 400 V

12
5,9-3,4

45

E3502108
E3501008

VLR 4 - 80 A M
VLR 4 - 80 A T

1,5

1 ~ 230 V
3 ~ 230 400 V

12
5,9-3,4

45

E3501010

VLR 4 - 100 A T

2,2

3 ~ 230 400 V

8,3-4,8

E3501012

VLR 4 - 120 A T

2,2

3 ~ 230 400 V

8,3-4,8

107

87

73

54

E3501014

VLR 4 - 140 A T

3 ~ 230 400 V

10,9-6,3

124 116 102

85

63

E3501016

VLR 4 - 160 A T

3 ~ 230 400 V

10,9-6,3

142 132 116

97

72

E3531019
E3531119

VLR 4 - 190 F T
VLR 4 - 190 F T

5,5

3 ~ 230 400 V
3 ~ 400 690 V

13,8-8

170 157 138 114

86

E3531022
E3531122

VLR 4 - 220 F T
VLR 4 - 220 F T

5,5

3 ~ 230 400 V
3 ~ 400 690 V

13,8-8

196 181 160 131 101

E3531024
E3531124

VLR 4 - 240 F T
VLR 4 - 240 F T

7,5

5,5

3 ~ 230 400 V
3 ~ 400 690 V

12,4-21,5

213 198 175 143 110

E3531026
E3531126

VLR 4 - 260 F T
VLR 4 - 260 F T

7,5

5,5

3 ~ 230 400 V
3 ~ 400 690 V

12,4-21,5

230 213 189 156 120

33

Discharge head
in meters

E3502102
E3501002

PRICE

VLR 4
Version with oval flanges
VLR 4-20 - VLR 4-160
H

B1

50

A1

L1

3/4"

22

60
100
156
160

22

65
3/8"

20

M 10x40

1 /4"gas

104
180
210

13,5

Version with round flanges


PN10 DIN 2534/ISO 7005-2

H
D

%) refer to one stage

B1

- Power ( Kw ) and efficiency (

Net weight
(kg)

Dimensions (mm)

3/4"

A1 1

3/8"

3/8"

75

A2

L2

Model

60
100
156
250
3/8"

20

32
78
100
140

n4 holes 18

104
180
210

13,5
4 holes

VLR 4 - 20
VLR 4 - 30
VLR 4 - 40
VLR 4 - 50
VLR 4 - 60
VLR 4 - 80/7
VLR 4 - 80
VLR 4 - 100
VLR 4 - 120
VLR 4 - 140
VLR 4 - 160
VLR 4 - 190
VLR 4 - 220
VLR 4 - 240
VLR 4 - 260

238
265
296
323
350
423
423
477
531
589
643
-

34

B1

213
213
237
237
237
265
265
265
265
315
315
335
335
385
385

L1 1

451
478
533
560
587
688
688
742
796
904
958
-

A2 2

749
830
911
965

L2 2

1084
1165
1298
1350

142
142
160
160
160
185
185
185
185
200
200
200
200
260
260

109
109
131
131
131
130
130
130
130
140
140
140
140
185
185

20
21
23
25
26
33
33
36
37
41
43
-

61
63
87
89

SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 8s are vertical multistage centrifugal pumps with "in line" suction
and delivery points directly connected to an electric motor.
They are not self-priming.
Design Features
- Impellers, diffusors, intermediate chambers and outer liner in AISI 304
stainless steel, shaft in AISI 431 stainless steel
- Base and head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- All the version "A" VLR are complete with 11/2" oval gas counterflanges
- For the version "F" VLR, round DN40 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure:
Oval flanges
: 16 bar
DIN flanges
: 25 bar (maximum pumped liquid temperature 85 C)
: 23 bar (maximum pumped liquid temperature 120 C)
- Maximum inlet pressure:
VLR 8-20 - VLR 8- 30 = 6 bar
VLR 8-40 - VLR 8-200 = 10 bar
- Minimum suction head:
please refer to the NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer

CODE

Motor
Power

MODEL

HP

kW

VOLTAGE

F.

Amp.

L/1'

50

100 150 175 200

Q
3

m /h

10,5

12

21

20

18

15

13

32

30

27

23

19

42

40

35

30

26

VLR 8 - 20 A M
VLR 8 - 20 A T

0,75

1 ~ 230 V
3 ~ 230 400 V

5,2
3,3-1,9

25

E4502103
E4501003

VLR 8 - 30 A M
VLR 8 - 30 A T

1,5

1,1

1 ~ 230 V
3 ~ 230 400 V

8
4,3-2,5

35

E4502104
E4501004

VLR 8 - 40 A M
VLR 8 - 40 A T

1,5

1 ~ 230 V
3 ~ 230 400 V

12
5,9-3,4

45

E4501005

VLR 8 - 50 A T

2,2

3 ~ 230 400 V

8,8-5,1

53

50

44

38

32

E4501006

VLR 8 - 60 A T

2,2

3 ~ 230 400 V

8,8-5,1

64

60

52

45

39

E4501008

VLR 8 - 80 A T

3 ~ 230 400 V

11,8-6,8

85

80

70

60

52

E4501010
E4501110

VLR 8 - 100 A T
VLR 8 - 100 A T

5,5

3 ~ 230 400 V
3 ~ 400 690 V

16,8-9,7

106 100

88

76

65

E4501012
E4501112

VLR 8 - 120 A T
VLR 8 - 120 A T

5,5

3 ~ 230 400 V
3 ~ 400 690 V

16,8-9,7

127 119 104

90

77

E4531014
E4531114

VLR 8 - 140 F T
VLR 8 - 140 F T

7,5

5,5

3 ~ 230 400 V
3 ~ 400 690 V

21,5-12,4

149 130 122 105

92

E4531016
E4531116

VLR 8 - 160 F T
VLR 8 - 160 F T

7,5

5,5

3 ~ 230 400 V
3 ~ 400 690 V

21,5-12,4

E4531018
E4531118

VLR 8 - 180 F T
VLR 8 - 180 F T

10

7,5

3 ~ 230 400 V
3 ~ 400 690 V

28-16,4

E4531020
E4531120

VLR 8 - 200 F T
VLR 8 - 200 F T

10

7,5

3 ~ 230 400 V
3 ~ 400 690 V

28-16,4

Discharge head
in meters

E4502102
E4501002

171 160 138 120 104


193 181 160 135 120
214 200 175 153 132

35

PRICE

VLR 8
Version with oval flanges
VLR 8-20 - VLR 8-120
H

B1

80

A1

L1

3/4"

27

130
190
200

27

100

20

M 12x45

1"1/2 gas

155
215
246

13

Version with round flanges


PN25 DIN 2534/ISO 7005-2

B1

A2

L2

D3

- Power ( Kw ) and efficiency (

3/8"

%) refer to one stage

3/8"

Net Weight
(kg)

Dimensions (mm)
Model
80

A1 1

130
190
280
3/8"

20

40
88
110
150

n4 holes 18

155
215
246

13
4 holes

VLR 8 - 20
VLR 8 - 30
VLR 8 - 40
VLR 8 - 50
VLR 8 - 60
VLR 8 - 80
VLR 8 - 100
VLR 8 - 120
VLR 8 - 140
VLR 8 - 160
VLR 8 - 180
VLR 8 - 200

245
375
420
450
480
545
605
665
-

36

B1

237
237
265
265
265
315
335
335
385
385
385
385

L1 1

482
612
685
715
745
860
940
1000
-

A2 2

745
805
865
925

L2 2

1130
1190
1250
1310

D3

160
160
185
185
185
200
200
200
260
260
260
260

131
131
130
130
130
140
140
140
185
185
185
185

300
300
300
300

30
32
40
42
43
51
52
56
-

85
86
90
91

SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 16s are vertical multistage centrifugal pumps with "in line"
suction and delivery points directly connected to an electric motor. They
are not self-priming.
Design Features
- Impellers, diffusors, intermediate chambers and outer liner in AISI 304
stainless steel, shaft in AISI 431 stainless steel
- Base and head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- Version with DIN/ISO flanges:
Flanges DN 50 PN25 DIN 2534/ISO 7005-2
(with 65mm diameter bore)
Counterflanges available on request: - weldable DN 50 PN 25
- 2" threaded gas
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure:
VLR 16- 30/2 - VLR 16- 80
= 16 bar
VLR 16-100 - VLR 16-160
= 25 bar (max. temp. 85 C)
VLR 16-100 - VLR 16-160
= 23 bar (max. temp. 120 C)
- Maximum inlet pressure:
VLR 16-30/2 - VLR 16- 30
= 6 bar
VLR 16-40
- VLR 16-160
=10 bar
- Minimum suction head:
please refer to the NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer

CODE

Motor
Power

MODEL

HP

kW

L/1'

VOLTAGE

Amp.

100 200 250 300 350

Q
m3/h

12

15

18

21

VLR 16 - 30/2F T

2,2

3 ~ 230 400 V

8,8-5,1

29

27

26

22

18

E5501003

VLR 16 - 30 F T

3 ~ 230 400 V

11,8-6,8

43

40

37

32

27

E5501004
E5501104

VLR 16 - 40 F T
VLR 16 - 40 F T

5,5

3 ~ 230 400 V
3 ~ 400 690 V

16,8-9,7

58

54

52

44

37

E5501005
E5501105

VLR 16 - 50 F T
VLR 16 - 50 F T

7,5

5,5

3 ~ 230 400 V
3 ~ 400 690 V

21,5-12,4

72

68

65

56

46

E5501006
E5501106

VLR 16 - 60 F T
VLR 16 - 60 F T

7,5

5,5

3 ~ 230 400 V
3 ~ 400 690 V

21,5-12,4

87

81

78

68

58

E5501007
E5501107

VLR 16 - 70 F T
VLR 16 - 70 F T

10

7,5

3 ~ 230 400 V
3 ~ 400 690 V

28-16,4

101

95

90

80

67

E5501008
E5501108

VLR 16 - 80 F T
VLR 16 - 80 F T

10

7,5

3 ~ 230 400 V
3 ~ 400 690 V

28-16,4

116 108 102

92

76

E5501010
E5501110

VLR 16 - 100 F T
VLR 16 - 100 F T

15

11

3 ~ 230 400 V
3 ~ 400 690 V

40-23,5

145 136 130 118

98

E5501012
E5501112

VLR 16 - 120 F T
VLR 16 - 120 F T

15

11

3 ~ 230 400 V
3 ~ 400 690 V

40-23,5

E5501014
E5501114

VLR 16 - 140 F T
VLR 16 - 140 F T

20

15

3 ~ 230 400 V
3 ~ 400 690 V

50-29

E5501016
E5501116

VLR 16 - 160 F T
VLR 16 - 160 F T

20

15

3 ~ 230 400 V
3 ~ 400 690 V

50-29

37

Discharge head
in meters

E5501002

174 163 156 140 118


204 190 184 163 140
232 220 208 188 159

PRICE

VLR 16
H
D

D3

3/8"

90

3/8"

130
190
300

165

125

65
20

102

n 4 holes 18

DN 50
155
215

n 4 holes
13

246

- Power ( Kw ) and efficiency (

%) refer to one stage

Net Weight
(kg)

Dimensions (mm)
Model

VLR 16 - 30/2
VLR 16 - 30
VLR 16 - 40
VLR 16 - 50
VLR 16 - 60
VLR 16 - 70
VLR 16 - 80
VLR 16 - 100
VLR 16 - 120
VLR 16 - 140
VLR 16 - 160

D3

460
464
509
575
620
665
710
830
920
1010
1100

265
315
335
385
385
385
385
495
495
495
495

725
779
844
960
1005
1050
1095
1325
1425
1505
1595

185
200
200
260
260
260
260
260
260
310
310

130
140
140
185
185
185
185
185
185
230
230

140
250
250
300
300
300
300
350
350
350
350

38

52
56
59
82
84
90
92
136
140
181
185

SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 30Bs are vertical multistage centrifugal pumps with "in line"
suction and delivery points directly connected to an electric motor.
They are not self-priming.
Design Features
- Impellers, diffusor and upper spacer, shaft, outer liner and coupling
guard in stainless steel AISI 304
- Electric pump base and head and coupling in cast iron
- Shaft protected by a tungsten carbide liner
- Mechanical seal in silicon carbide and carbon (on request widia-widia)
- EPDM rubber O ring
- Supplied complete with counterflanges
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 20C to +120C
- M a x i m u m o p e r a t i n g p re s s u re i n c l u d i n g s u c t i o n h e a d :
16 bar (VLR 30-20 - VLR 30-60)
25 bar (VLR 30-70 - VLR 30-120)
- Minimum suction head:
please refer to the NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general.

CODE

Motor
Power

MODEL

VOLTAGE

HP

kW

Amp.

L/1

233

300

350

400

500

600

m3 /h

14

18

21

24

30

36

VLR 30B - 20 FT

5,50

4,00

3 ~ 400/690 V

8,6

39

37

35

32,5

26,5

19

E6500020

VLR 30B - 30 FT

7,50

5,50

3 ~ 400/690 V

11,3

58

55

53

48

40

29

E6500030

VLR 30B - 40 FT 10,00

7,50

3 ~ 400/690 V

14,7

78

74

70

65

53

38

E6500040

VLR 30B - 50 FT 15,00

11,00

3 ~ 400/690 V

21,0

97

92

88

81

66

48

E6500050

VLR 30B - 60 FT 15,00

11,00

3 ~ 400/690 V

21,0

117

110

105

97

79

58

E6500060

VLR 30B - 70 FT 20,00

15,00

3 ~ 400/690 V

29,0

136

129

123

113

92

67

E6500070

VLR 30B - 80 FT 20,00

15,00

3 ~ 400/690 V

29,0

155

147

140

130

106

77

E6500080

VLR 30B - 90 FT 20,00

15,00

3 ~ 400/690 V

29,0

175

166

158

146

119

86

E6500090

VLR 30B - 100 FT 25,00

18,50

3 ~ 400/690 V

35,0

194

184

175

162

132

96

E6500100

VLR 30B - 110 FT 25,00

18,50

3 ~ 400/690 V

35,0

214

202

193

178

145

106

E6500110

VLR 30B - 120 FT 30,00

22,00

3 ~ 400/690 V

42,0

233

221

210

194

158

115

39

Discharge head
in meters

E6500010

PRICE

VLR 30B

D2

L1

G 1/2 LOAD

Rp 3/8

Rp 3/8

DNA

DNM

A
35

B
G 1/2 LOAD

220
260

L1+L2

L2

15
N 4 HOLES

220
260

- Power ( Kw ) and efficiency (

%) refer to one stage

Net Weight
kg

Dimensions in mm
Model
DNA/
DNM

L1

L2

D1

D2

Pump- Electric
pump
end

VLR 30B - 20

65

588

312

105

320

136

193

160

170

48

78

VLR 30B - 30

65

680

350

105

320

150

220

300

190

56

102

VLR 30B - 40

65

752

350

105

320

150

220

300

190

59

109

VLR 30B - 50

65

856

856

105

320

228

316

350

222

70

155

VLR 30B - 60

65

1120

495

105

320

228

316

350

222

83

168

VLR 30B - 70

65

1192

495

105

320

228

316

350

222

86

178

VLR 30B - 80

65

1264

495

105

320

228

316

350

222

89

181

VLR 30B - 90

65

1336

495

105

320

228

316

350

222

93

185

VLR 30B - 100

65

1408

495

105

320

228

316

350

222

96

195

VLR 30B - 110

65

1480

495

105

320

228

316

350

222

99

198

VLR 30B - 120

65

1552

495

105

320

245

316

350

222

102

216

40

SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 60Bs are vertical multistage centrifugal pumps with "in line"
suction and delivery points directly connected to an electric motor.
They are not self-priming.
Design Features
- Impellers, diffusor and upper spacer, shaft, outer liner and coupling
guard in stainless steel AISI 304
- Electric pump base and head and coupling in cast iron
- Shaft protected by a tungsten carbide liner
- Mechanical seal in silicon carbide and carbon
(on request widia-widia)
- EPDM rubber O ring
- Supplied complete with counterflanges
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 20C to 120C
- Maximum operating pressure including suction head: 16 bar
- Minimum suction head:
please refer to the NPSH values with a safety margin of 0.5 m water
column
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general

CODE

Motor
Power

MODEL

VOLTAGE

HP

kW

Amp.

L/1

400

500

600

800 1000

1200

m3 /h

24

30

36

48

60

72

VLR 60B - 20 FT

7,50

5,50

3 ~ 400/690 V

11,3

33

32

30

25

19

12

E7500020

VLR 60B - 30 FT

10,00

7,50

3 ~ 400/690 V

14,7

51

48

45

38

28

17

E7500030

VLR 60B - 40 FT

15,00

11,00

3 ~ 400/690 V

21,0

67

63

60

51

38

23

E7500040

VLR 60B - 50 FT

20,00

15,00

3 ~ 400/690 V

29,0

84

80

75

63

48

28

E7500050

VLR 60B - 60 FT

20,00

15,00

3 ~ 400/690 V

29,0

102

96

90

76

58

35

E7500060

VLR 60B - 70 FT

25,00

18,50

3 ~ 400/690 V

35,0

118

112

105

88

67

E7500070

VLR 60B - 80 FT

30,00

22,00

3 ~ 400/690 V

42,0

135

128

120

102

77

41

Discharge head
in meters

E7500010

40
46

PRICE

VLR 60B

D2

L1

G 1/2 LOAD

Rp 3/8

Rp 3/8

DNM

DNA

35

B
G 1/2 LOAD

220
260

L1+L2

L2

15
N 4 HOLES

220
260

- Power ( Kw ) and efficiency (

%) refer to one stage

Net Weight
kg

Dimensions mm
Model
DNA/
DNM

L1

VLR 60B - 20

100

VLR 60B - 30
VLR 60B - 40
VLR 60B - 50
VLR 60B - 60

Pump- Electric
end
pump

L2

D1

D2

658

350

140

365

150

220

300

190

57

103

100

730

350

140

365

150

220

300

190

60

110

100

834

495

140

365

228

316

350

222

71

156

100

906

495

140

365

228

316

350

222

74

166

100

1170

495

140

365

228

316

350

222

87

179

VLR 60B - 70

100

1242

495

140

365

228

316

350

222

90

189

VLR 60B - 80

100

1314

495

140

365

245

316

350

222

94

208

42

SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLRI 2Bs (Version "A" with oval flanges) are vertical multistage
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Design Features
- Base, impellers, diffusors, intermediate chambers and outer liner in
stainless steel AISI 304
- Electric pump head and coupling in GG20 cast iron
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- EPDM rubber O ring
- The VLRI 2B, A version, are complete with 11/4" oval gas counterflanges
in steel AISI 316
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to 120C
- Maximum operating pressure: 16 bar
- Maximum inlet pressure: VLRI 2B- 30/2
= 6 bar
VLRI 2B- 30 - VLRI 2B-110 = 10 bar
VLRI 2B-130 - VLRI 2B-150 = 15 bar
- Minimum suction head:
please refer to the NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general

Motor
Power

MODEL

HP

kW

VOLTAGE

Amp.

F.

L/1

10

20

30

40

50

m /h

0,6

1,2

1,8

2,4

3,0

19

18

17

14

11

29

27

25

21

17

37

35

32

29

23

47

43

40

35

28

56

51

48

42

33

65

60

55

49

39

84

78

70

62

50

100

93

84

74

60

120

112

102

89

71

138

129

116

99

81

PRICE

Q
3

E2402010
E2402020

VLRI 2B- 30/2 A M


VLRI 2B- 30/2 A T

0,50

0,37

1 ~ 230 V
3 ~ 230/400 V

2,7
1,0 - 0,6

14

E2402030
E2402040

VLRI 2B- 30
VLRI 2B- 30

AM
AT

0,50

0,37

1 ~ 230 V
3 ~ 230/400 V

2,7
1,4 - 0,8

14

E2402050
E2402060
E2402070
E2402080

VLRI 2BVLRI 2BVLRI 2BVLRI 2B-

40
40
50
50

AM
AT
AM
AT

0,75

0,55

1 ~ 230 V
3 ~ 230/400 V

4,0
1,8 - 1,0

16

0,75

0,55

1 ~ 230 V
3 ~ 230/400 V

4,0
2,3 - 1,3

16

E2402090
E2402100

VLRI 2B- 60
VLRI 2B- 60

AM
AT

1,00

0,75

1 ~ 230 V
3 ~ 230/400 V

5,2
2,7 - 1,5

25

E2402110
E2402120

VLRI 2B- 70
VLRI 2B- 70

AM
AT

1,00

0,75

1 ~ 230 V
3 ~ 230/400 V

5,2
3,0 - 1,7

25

E2402130
E2402140

VLRI 2B- 90
VLRI 2B- 90

AM
AT

1,50

1,10

1 ~ 230 V
3 ~ 230/400 V

8,0
3,6 - 2,1

35

E2402150
E2402160

VLRI 2B-110 A M
VLRI 2B-110 A T

1,50

1,10

1 ~ 230 V
3 ~ 230/400 V

8,0
4,3 - 2,5

35

E2402170
E2402180

VLRI 2B-130
VLRI 2B-130

AM
AT

2,00

1,50

1 ~ 230 V
3 ~ 230/400 V

12,0
5,0 - 2,9

45

E2402190
E2402200

VLRI 2B-150
VLRI 2B-150

AM
AT

2,00

1,50

1 ~ 230 V
3 ~ 230/400 V

12,0
5,7 - 3,3

45

43

Discharge head
in meters

CODE

VLRI 2B
H

50

3/4"

22

64
100
156
160

22

65
3/8"

M 10x40

20

11/4"gas

104
180
210

13,5
n. 4 holes

- Power ( Kw ) and efficiency (

%) refer to one stage

Net Weight
kg

Dimensions mm
Model

VLRI 2B - 30/2 A
VLRI 2B - 30 A
VLRI 2B - 40 A
VLRI 2B - 50 A
VLRI 2B - 60 A
VLRI 2B - 70 A
VLRI 2B - 90 A
VLRI 2B - 110 A
VLRI 2B - 130 A
VLRI 2B - 150 A

263
263
281
299
321
339
375
411
466
502

215
215
215
215
245
245
245
245
255
255

478
478
496
514
566
584
620
656
721
757

158
158
158
158
170
170
170
170
180
180

168
168
168
168
203
203
203
203
205
205

44

20
21
23
25
26
33
34
36
37
43

SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLRI 2Bs (Version "F" with round flanges) are vertical multistage
electric centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Design Features
- Base, impellers, diffusors, intermediate chambers and outer liner in
stainless steel AISI 304
- Electric pump head and coupling in GG20 cast iron
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- EPDM rubber O ring
- For the version "F" VLRI, round DN 32 counterflanges on request
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to 120C
- Maximum operating pressure:
25 bar (max. pumped liquid temperature 40 C)
21 bar (max. pumped liquid temperature 120 C)
- Maximum inlet pressure: VLRI 2B- 30/2
VLRI 2B- 30 - VLRI 2B-110
VLRI 2B- 130 - VLRI 2B-260
- Minimum suction head:
please refer to the NPSH values with a safety margin

= 6 bar
= 10 bar
= 15 bar
of 0.5 m

Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general

Motor
Power

MODEL

VOLTAGE

HP

kW

E2400010
E2400020

VLRI 2B- 30/2 F M


VLRI 2B- 30/2 F T

0,50

0,37

E2400030
E2400040

VLRI 2B- 30
VLRI 2B- 30

FM
FT

0,50

E2400050
E2400060

VLRI 2B- 40
VLRI 2B- 40

FM
FT

E2400070
E2400080

VLRI 2B- 50
VLRI 2B- 50

E2400090
E2400100

Amp.

F.

1 ~ 230 V

2,7

3 ~ 230400 V

1,0 - 0,6

0,37

1 ~ 230 V
3 ~ 230400 V

2,7
1,4 - 0,8

14

0,75

0,55

1 ~ 230 V
3 ~ 230400 V

4,0
1,8 - 1,0

16

FM
FT

0,75

0,55

1 ~ 230 V
3 ~ 230400 V

4,0
2,3 - 1,3

16

VLRI 2B- 60
VLRI 2B- 60

FM
FT

1,00

0,75

1 ~ 230 V
3 ~ 230400 V

5,2
2,7 - 1,5

25

E2400110
E2400120

VLRI 2B- 70
VLRI 2B- 70

FM
FT

1,00

0,75

25

E2400130
E2400140

VLRI 2B- 90
VLRI 2B- 90

FM
FT

1,50

E2400150
E2400160

VLRI 2B-110
VLRI 2B-110

FM
FT

E2400170
E2400180

VLRI 2B-130
VLRI 2B-130

E2400190
E2400200

L/1

10

20

30

40

50

m3 /h

0,6

1,2

1,8

2,4

3,0

19

18

17

14

11

29

27

25

21

17

37

35

32

29

23

47

43

40

35

28

56

51

48

42

33

65

60

55

49

39

84

78

70

62

50

100

93

84

74

60

120

112

102

89

71

138

129

116

99

81

PRICE

14

Discharge head
in meters

CODE

1 ~ 230 V

5,2

3 ~ 230400 V

3,0 - 1,7

1,10

1 ~ 230 V
3 ~ 230400 V

8,0
3,6 - 2,1

35

1,50

1,10

1 ~ 230 V
3 ~ 230400 V

8,0
4,3 - 2,5

35

FM
FT

2,00

1,50

1 ~ 230 V
3 ~ 230400 V

12,0
5,0 - 2,9

45

VLRI 2B-150
VLRI 2B-150

FM
FT

2,00

1,50

1 ~ 230 V
3 ~ 230400 V

12,0
5,7 - 3,3

45

E2400210

VLRI 2B-180

FT

3,00

2,20

3 ~ 230400 V

7,2 - 4,1

166

155

141

122

99

E2400220

VLRI 2B-220

FT

3,00

2,20

3 ~ 230400 V

8,7 - 5,0

199

185

168

145

118

E2400230

VLRI 2B-260

FT

4,00

3,00

3 ~ 230400 V

11,4 - 6,6

232

220

200

173

141

45

VLRI 2B
H

3/8"

3/8"

75

3/4"

60
100
156
250

3/8"

20

32
78
100
140

n4 holes 18

104
180
210

13,5
n. 4 holes

- Power ( Kw ) and efficiency (

%) refer to one stage

Net Weight
kg

Dimensions mm
Model

VLRI 2B - 30/2 F
VLRI 2B - 30 F
VLRI 2B - 40 F
VLRI 2B - 50 F
VLRI 2B - 60 F
VLRI 2B - 70 F
VLRI 2B - 90 F
VLRI 2B - 110 F
VLRI 2B - 130 F
VLRI 2B - 150 F
VLRI 2B - 180 F
VLRI 2B - 220 F
VLRI 2B - 260 F

250
250
268
286
308
326
362
388
453
489
568
640
716

215
215
215
215
245
245
245
245
255
255
280
280
300

465
465
483
501
553
571
607
633
708
744
848
920
1016

158
158
158
158
170
170
170
170
180
180
180
180
196

168
168
168
168
203
203
203
203
205
205
205
205
235

46

26
27
29
31
32
39
39
42
43
49
49
61
63

SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 4s (Version "A" with oval flanges) are vertical multistage electric
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Design Features
- Base, impellers, diffusors, intermediate chambers and outer liner in
stainless steel AISI 304
- Electric pump head and coupling in GG20 cast iron
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- EPDM rubber O ring
- The VLRI 4, version A, are complete with 11/4" oval gas counterflanges
in steel AISI 316
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to 120C
- Maximum operating pressure: 16 bar
- Maximum inlet pressure:
VLRI 4- 20
=
VLRI 4- 30 - VLRI 4-100 =
VLRI 4-120 - VLRI 4-160 =
- Minimum suction head:
please refer to the NPSH values with a safety margin of

6 bar
10 bar
15 bar
0.5 m

Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general

Motor
Power

MODEL
HP

kW

VOLTAGE

Amp.

F.

E3602010
E3602020

VLRI 4- 20 A M
VLRI 4- 20 A T

0,50

0,37

1 ~ 230 V
3 ~ 230400 V

2,7
1,7 - 1,0

14

E3602030
E3602040

VLRI 4- 30 A M
VLRI 4- 30 A T

0,75

0,55

1 ~ 230 V
3 ~ 230400 V

4,0
2,5 - 1,4

16

E3602050
E3602060
E3602070
E3602080

VLRI 4VLRI 4VLRI 4VLRI 4-

1,00

0,75

1 ~ 230 V
3 ~ 230400 V

5,2
3,3 - 1,9

25

1,50

1,10

1 ~ 230 V
3 ~ 230400 V

8,0
4,3 - 2,5

35

E3602090
E3602100

VLRI 4- 60 A M
VLRI 4- 60 A T

1,50

1,10

1 ~ 230 V
3 ~ 230400 V

8,0
4,3 - 2,5

35

E3602110
E3602120

VLRI 4- 80/7 A M
VLRI 4- 80/7 A T

2,00

1,50

1 ~ 230 V
3 ~ 230400 V

12
5,9 - 3,4

45

E3602130
E3602140

VLRI 4- 80 A M
VLRI 4- 80 A T

2,00

1,50

45

E3602150

VLRI 4-100 A T

3,00

E3602160

VLRI 4-120 A T

E3602170
E3602180

40
40
50
50

A
A
A
A

M
T
M
T

L/1

40

60

80

100

120

m3 /h

2,4

3,6

4,8

6,0

7,2

19

17

15

13

28

25

22

19

13

36

33

29

25

18

44

42

37

31

23

53

50

44

38

27

61

58

51

44

32

71

67

59

50

37

PRICE

Discharge head
in meters

CODE

1 ~ 230 V

12

3 ~ 230400 V

5,9 - 3,4

2,20

3 ~ 230400 V

8,3 - 4,8

90

82

72

61

46

3,00

2,20

3 ~ 230400 V

8,3 - 4,8

107

99

87

73

54

VLRI 4-140 A T

4,00

3,00

3 ~ 230400 V

10,9 - 6,3

124

116

102

85

63

VLRI 4-160 A T

4,00

3,00

3 ~ 230400 V

10,9 - 6,3

142

132

116

97

72

47

VLRI 4
H

50

3/4"

22

64
100
156
160

22

65
3/8"

M 10x40

20

11/4"gas

104
180
210

13,5
n. 4 holes

- Power ( Kw ) and efficiency (

%) refer to one stage

Net Weight
kg

Dimensions mm
Model

VLRI 4 - 20 A
VLRI 4 - 30 A
VLRI 4 - 40 A
VLRI 4 - 50 A
VLRI 4 - 60 A
VLRI 4 - 80/7 A
VLRI 4 - 80 A
VLRI 4 - 100 A
VLRI 4 - 120 A
VLRI 4 - 140 A
VLRI 4 - 160 A

263
290
321
348
375
448
448
502
556
614
668

215
215
245
245
245
255
255
280
280
300
300

478
505
566
593
620
703
703
782
836
914
968

158
158
170
170
170
180
180
180
180
196
196

168
168
203
203
203
205
205
205
205
235
235

48

20
21
23
25
26
33
34
36
37
43
43

SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLRI 4s (Version "F" with round flanges) are vertical multistage
electric centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Design Features
- Base, impellers, diffusors, intermediate chambers and outer liner in
stainless steel AISI 304
- Electric pump head and coupling in GG20 cast iron
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- EPDM rubber O ring
- For the version "F" VLRI, round DN 32 counterflanges on request
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to 120C
- Maximum operating pressure:
25 bar (max. pumped liquid temperature
40 C)
21 bar (max. pumped liquid temperature 120 C)
- Maximum inlet pressure:
VLRI 4- 20
= 6 bar
VLRI 4- 30 - VLRI 4-100 = 10 bar
VLRI 4-120 - VLRI 4-260 = 15 bar
- Minimum suction head:
please refer to the NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general

CODE

Motor
Power

MODEL

HP

kW

E3600010
E3600020

VLRI 4- 20
VLRI 4- 20

FM
FT

0,50

0,37

E3600030
E3600040

VLRI 4- 30
VLRI 4- 30

FM
FT

0,75

E3600050
E3600060

VLRI 4- 40
VLRI 4- 40

FM
FT

1,00

E3600070
E3600080

VLRI 4- 50
VLRI 4- 50

FM
FT

E3600090
E3600100

VLRI 4- 60
VLRI 4- 60

FM
FT

E3600110
E3600120

VLRI 4- 80/7 F M
VLRI 4- 80/7 F T

2,00

1,50

E3600130
E3600140

VLRI 4- 80
VLRI 4- 80

FM
FT

2,00

E3600150

VLRI 4-100

FT

E3600160

VLRI 4-120

E3600170

VOLTAGE

Amp.

F. Q

L/1

40

60

80

100

120

m3 /h

2,4

3,6

4,8

6,0

7,2

19

17

15

13

28

25

22

19

13

36

33

29

25

18

44

42

37

31

23

53

50

44

38

27

61

58

51

44

32

71

67

59

50

37

90

82

72

61

46

107

99

87

73

54

PRICE

1 ~ 230 V

2,7

3 ~ 230400 V

1,7 - 1,0

0,55

1 ~ 230 V
3 ~ 230400 V

4,0
2,5 - 1,4

16

0,75

1 ~ 230 V
3 ~ 230400 V

5,2
3,3 - 1,9

25

1,50

1,10

1 ~ 230 V
3 ~ 230400 V

8,0
4,3 - 2,5

35

1,50

1,10

1 ~ 230 V
3 ~ 230400 V

8,0
4,3 - 2,5

35

1 ~ 230 V

12

45

3 ~ 230400 V

5,9 - 3,4

1,50

1 ~ 230 V
3 ~ 230400 V

12
5,9 - 3,4

3,00

2,20

3 ~ 230400 V

8,3 - 4,8

FT

3,00

2,20

3 ~ 230400 V

8,3 - 4,8

VLRI 4-140

FT

4,00

3,00

3 ~ 230400 V

10,9 - 6,3

124

116

102

85

63

E3600180

VLRI 4-160

FT

4,00

3,00

3 ~ 230400 V

10,9 - 6,3

142

132

116

97

72

E3600250
E3600190
E3600260
E3600200

VLRI 4-190
VLRI 4-190

FT
FT

5,50

4,00

170

157

138

114

86

VLRI 4-220
VLRI 4-220

FT
FT

5,50

196

181

160

131

101

E3600230
E3600210

VLRI 4-240
VLRI 4-240

FT
FT

213

198

175

143

110

E3600220
E3600240

VLRI 4-260
VLRI 4-260

FT
FT

230

231

189

156

120

3 ~ 230400 V
3 ~ 400690 V

13,8 - 8,0

4,00

3 ~ 230400 V
3 ~ 400690 V

13,8 - 8,0

7,50

5,50

3 ~ 230400 V
3 ~ 400690 V

12,4 - 21,5

7,50

5,50

3 ~ 230400 V
3 ~ 400690 V

12,4 - 21,5

49

45

Discharge head
in meters

14

VLRI 4
H

3/8"

3/8"

75

3/4"

60
100
156
250

3/8"

20

32
78
100
140

n4 holes 18

104
180
210

13,5
n. 4 holes

- Power ( Kw ) and efficiency (

%) refer to one stage

Net Weight
kg

Dimensions mm
Model

VLRI 4 - 20 F
VLRI 4 - 30 F
VLRI 4 - 40 F
VLRI 4 - 50 F
VLRI 4 - 60 F
VLRI 4 - 80/7 F
VLRI 4 - 80 F
VLRI 4 - 100 F
VLRI 4 - 120 F
VLRI 4 - 140 F
VLRI 4 - 160 F
VLRI 4 - 190 F
VLRI 4 - 220 F
VLRI 4 - 240 F
VLRI 4 - 260 F

250
277
308
335
362
435
435
489
543
601
655
761
842
923
977

215
215
245
245
245
255
255
280
280
300
300
325
325
390
390

465
492
553
580
607
690
690
769
823
901
955
1086
1167
1313
1367

158
158
170
170
170
180
180
180
180
196
196
218
218
300
300

168
168
203
203
203
205
205
205
205
235
235
256
256
350
350

50

26
27
29
31
32
39
39
42
43
49
49
61
63
87
89

SURFACE PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX 2Bs (Version A with oval flanges) are vertical multistage
electric centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Entirely in AISI 316 stainless steel for sea water and special applications.
Design Features
- Impellers, shaft, diffusors, intermediate chambers, outer liner and pump
base in AISI 316 stainless steel
- Pump head in GG20 cast iron
- EPDM rubber O ring
- Complete with 11/4" oval gas counterflanges
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure: 16 bar
- Maximum inlet pressure:
VLRX 2B- 30/2
VLRX 2B- 30 - VLRX 2B-110
VLRX 2B-130 - VLRX 2B-150
- Minimum suction head:
please refer to the NPSH values with a safety margin

= 6 bar
= 10 bar
= 15 bar
of 0.5 m

Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer

VICTAULIC VERSION AVAILABLE

MODEL

Motor
Power
HP

kW

VOLTAGE

F.

Amp.

L/1'

VLRX 2B - 30/2 A M
VLRX 2B - 30/2 A T

0,5

0,37

1 ~ 230 V
3 ~ 230 400 V

2,7
1 - 0,6

14

E2632103
E2631003

VLRX 2B - 30 A M
VLRX 2B - 30 A T

0,5

0,37

1 ~ 230 V
3 ~ 230 400 V

2,7
1,4 - 0,8

14

E2632104
E2631004

VLRX 2B - 40 A M
VLRX 2B - 40 A T

0,75

0,55

1 ~ 230 V
3 ~ 230 400 V

4
1,8 - 1

16

E2632105
E2631005

VLRX 2B - 50 A M
VLRX 2B - 50 A T

0,75

0,55

1 ~ 230 V
3 ~ 230 400 V

4
2,3 - 1,3

16

E2632106
E2631006

VLRX 2B - 60 A M
VLRX 2B - 60 A T

0,75

1 ~ 230 V
3 ~ 230 400 V

5,2
2,7 - 1,5

25

E2632107
E2631007

VLRX 2B - 70 A M
VLRX 2B - 70 A T

0,75

1 ~ 230 V
3 ~ 230 400 V

5,2
3 - 1,7

25

E2632108
E2631008

VLRX 2B - 90 A M
VLRX 2B - 90 A T

1,5

1,1

1 ~ 230 V
3 ~ 230 400 V

8
3,6 - 2,1

35

E2632110
E2631010

VLRX 2B - 110 A M
VLRX 2B - 110 A T

1,5

1,1

1 ~ 230 V
3 ~ 230 400 V

8
4,3 - 2,5

35

E2632112
E2631012

VLRX 2B - 130 A M
VLRX 2B - 130 A T

1,5

1 ~ 230 V
3 ~ 230 400 V

12
5 - 2,9

45

E2632114
E2631014

VLRX 2B - 150 A M
VLRX 2B - 150 A T

1,5

1 ~ 230 V
3 ~ 230 400 V

12
5,7 - 3,3

45

51

20

30

40

50

0,6

1,2

1,8

2,4

19

18

17

14

11

29

27

25

21

17

37

35

32

29

23

47

43

40

25

28

56

51

48

42

33

65

60

55

49

39

84

78

70

62

50

100

93

84

74

60

120 112 102

89

71

138 129 116

99

81

PRICE
3

m /h

E2632102
E2631002

10

Discharge head
in meters

CODE

VLRX 2B
H

50

3/4"

22

64
100
156
160

22

65
3/8"

M 10x40

20

11/4"gas

104
180
210

13,5
n. 4 holes

- Power ( Kw ) and efficiency (

%) refer to one stage

VLRX 2B - 30/2 A
VLRX 2B - 30 A
VLRX 2B - 40 A
VLRX 2B - 50 A
VLRX 2B - 60 A
VLRX 2B - 70 A
VLRX 2B - 90 A
VLRX 2B - 110 A
VLRX 2B - 130 A
VLRX 2B - 150 A

Net Weight
kg

Dimensions mm.

Model
A

237
237
255
273
297
315
351
387
439
475

216
216
216
216
241
241
241
241
260
260

453
453
471
488
538
556
592
628
699
735

141
141
141
141
158
158
158
158
176
176

101
101
101
101
115
115
115
115
115
115

52

20
21
23
25
26
33
33
36
37
43

SURFACE PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX 2Bs (Version F with round flanges) are vertical multistage
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Entirely in AISI 316 stainless steel for sea water and special applications.
Design Features
- Impellers, shaft, diffusors, intermediate chambers, outer liner and pump
base in AISI 316 stainless steel
- Pump head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- For the version "F" VLRX, round DN 32 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation;
- level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure: 25 bar
- Maximum head pressure:
VLRX 2B- 30/2
VLRX 2B- 30 - VLRX 2B-110
VLRX 2B-130 - VLRX 2B-260
- Minimum suction head:
please refer to the NPSH values with a safety margin

= 6 bar
= 10 bar
= 15 bar
of 0.5 m

Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer

CODE

Motor
Power

MODEL

HP

VOLTAGE

Amp.

VICTAULIC VERSION AVAILABLE

F.

kW

L/1

10

20

30

40

50

m3 /h

0,6

1,2

1,8

2,4

3,0

19

18

17

14

11

29

27

25

21

17

37

35

32

29

23

47

43

40

35

28

56

51

48

42

33

65

60

55

49

39

84

78

70

62

50

100

93

84

74

60

120

112

102

89

71

138

129

116

99

81

PRICE

E2730010 VLRX 2B- 30/2 F M


E2730020 VLRX 2B- 30/2 F T 0,50 0,37

1 ~ 230 V

2,7

3 ~ 230400 V

1,0 - 0,6

E2730030 VLRX 2B- 30


E2730040 VLRX 2B- 30

FM
F T 0,50 0,37

1 ~ 230 V
3 ~ 230400 V

2,7
1,4 - 0,8

14

E2730050 VLRX 2B- 40


E2730060 VLRX 2B- 40

FM
F T 0,75 0,55

1 ~ 230 V
3 ~ 230400 V

4,0
1,8 - 1,0

16

E2730070 VLRX 2B- 50


E2730080 VLRX 2B- 50

FM
0,55
F T 0,75

1 ~ 230 V
3 ~ 230400 V

4,0
2,3 - 1,3

16

E2730090 VLRX 2B- 60


E2730100 VLRX 2B- 60

FM
F T 1,00 0,75

1 ~ 230 V
3 ~ 230400 V

5,2
2,7 - 1,5

25

E2730110 VLRX 2B- 70


E2730120 VLRX 2B- 70

FM
F T 1,00 0,75

1 ~ 230 V

5,2

25

3 ~ 230400 V

3,0 - 1,7

E2730130 VLRX 2B- 90


E2730140 VLRX 2B- 90

FM
F T 1,50 1,10

1 ~ 230 V
3 ~ 230400 V

8,0
3,6 - 2,1

35

E2730150 VLRX 2B-110


E2730160 VLRX 2B-110

FM
F T 1,50 1,10

1 ~ 230 V
3 ~ 230400 V

8,0
4,3 - 2,5

35

E2730170 VLRX 2B-130


E2730180 VLRX 2B-130

FM
2,00 1,50
FT

1 ~ 230 V
3 ~ 230400 V

12,0
5,0 - 2,9

45

E2730190 VLRX 2B-150


E2730200 VLRX 2B-150

FM
2,00 1,50
FT

1 ~ 230 V
3 ~ 230400 V

12,0
5,7 - 3,3

45

E2730210 VLRX 2B-180

FT

3,00 2,20

3 ~ 230400 V

7,2 - 4,1

166

155

141

122

99

E2730220 VLRX 2B-220

FT

3,00 2,20

3 ~ 230400 V

8,7 - 5,0

199

185

168

145

118

E2730230 VLRX 2B-260

FT

4,00 3,00

3 ~ 230400 V

11,4 - 6,6

232

220

200

173

141

53

Discharge head
in meters

14

VLRX 2B
H

3/8"

3/8"

75

3/4"

60
100
156
250

3/8"

20

32
78
100
140

n4 holes 18

104
180
210

13,5
n. 4 holes

- Power ( Kw ) and efficiency (

%) refer to one stage

Net Weight
kg

Dimensions mm
Model

VLRX 2B - 30/2 F
VLRX 2B - 30 F
VLRX 2B - 40 F
VLRX 2B - 50 F
VLRX 2B - 60 F
VLRX 2B - 70 F
VLRX 2B - 90 F
VLRX 2B - 110 F
VLRX 2B - 130 F
VLRX 2B - 150 F
VLRX 2B - 180 F
VLRX 2B - 220 F
VLRX 2B - 260 F

250
250
268
286
308
326
362
388
453
489
568
640
716

215
215
215
215
245
245
245
245
255
255
280
280
300

465
465
483
501
553
571
607
633
708
744
848
920
1016

158
158
158
158
170
170
170
170
180
180
180
180
196

168
168
168
168
203
203
203
203
205
205
205
205
235

54

26
27
29
31
32
39
39
42
43
49
49
61
63

SURFACE PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX 4s (Version A with oval flanges) are vertical multistage
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Entirely in AISI 316 stainless steel for sea water and special applications.
Design Features
- Impellers, shaft, diffusors, intermediate chambers, outer liner and pump
base in AISI 316 stainless steel
- Pump head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- Complete with 11/4" oval gas counterflanges
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure: 16 bar
- Maximum inlet pressure:
VLRX 4- 20
VLRX 4- 30 - VLRX 4-100
VLRX 4-120 - VLRX 4-160
- Minimum suction head:
please refer to the NPSH values with a safety margin

= 6 bar
= 10 bar
= 15 bar
of 0.5 m

Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general

VICTAULIC VERSION AVAILABLE

CODE

Motor
Power

MODEL

HP

kW

VOLTAGE

Amp.

F.

L/1'

40

60

80

m3/h

2,4

3,6

4,8

7,2

19

17

15

13

28

25

22

19

13

36

33

29

25

18

44

42

37

31

23

53

50

44

38

27

61

58

51

44

32

71

67

59

50

37

100 120

PRICE

VLRX 4 - 20 A M
VLRX 4 - 20 A T

0,5

0,37

1 ~ 230 V
3 ~ 230 400 V

2,7
1,73-1

14

E3632103
E3631003

VLRX 4 - 30 A M
VLRX 4 - 30 A T

0,75

0,55

1 ~ 230 V
3 ~ 230 400 V

4
2,5-1,45

16

E3632104
E3631004

VLRX 4 - 40 A M
VLRX 4 - 40 A T

0,75

1 ~ 230 V
3 ~ 230 400 V

5,2
3,3-1,9

25

E3632105
E3631005

VLRX 4 - 50 A M
VLRX 4 - 50 A T

1,5

1,1

1 ~ 230 V
3 ~ 230 400 V

8
4,3-2,5

35

E3632106
E3631006

VLRX 4 - 60 A M
VLRX 4 - 60 A T

1,5

1,1

1 ~ 230 V
3 ~ 230 400 V

8
4,3-2,5

35

E3632107
E3631007

VLRX 4 - 80/7 A M
VLRX 4 - 80/7 A T

1,5

1 ~ 230 V
3 ~ 230 400 V

12
5,9-3,4

45

E3632108
E3631008

VLRX 4 - 80 A M
VLRX 4 - 80 A T

1,5

1 ~ 230 V
3 ~ 230 400 V

12
5,9-3,4

45

E3631010

VLRX 4 - 100 A T

2,2

3 ~ 230 400 V

8,3-4,8

90

82

72

61

46

E3631012

VLRX 4 - 120 A T

2,2

3 ~ 230 400 V

8,3-4,8

107

99

87

73

54

E3631014

VLRX 4 - 140 A T

3 ~ 230 400 V

10,9-6,3

124 116 102

85

63

E3631016

VLRX 4 - 160 A T

3 ~ 230 400 V

10,9-6,3

142 132 116

97

72

55

Discharge head
in meters

E3632102
E3631002

VLRX 4

50

3/4"

22

64
100
156
160

22

65
3/8"

M 10x40

20

11/4"gas

104
180
210

13,5
n. 4 holes

- Power ( Kw ) and efficiency (

%) refer to one stage

VLRX 4 - 20 A
VLRX 4 - 30 A
VLRX 4 - 40 A
VLRX 4 - 50 A
VLRX 4 - 60 A
VLRX 4 - 80/7 A
VLRX 4 - 80 A
VLRX 4 - 100 A
VLRX 4 - 120 A
VLRX 4 - 140 A
VLRX 4 - 160 A

Net Weight
kg

Dimensions mm.

Model
A

235
262
289
316
347
401
401
455
528
636
636

215
215
237
237
237
277
277
277
277
323
323

450
477
526
553
584
678
678
732
805
959
959

141
141
158
158
158
179
179
179
179
197
197

115
115
142
142
142
145
145
145
145
165
165

56

20
21
23
25
26
33
33
36
37
43
43

SURFACE PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX 4s (Version F with round flanges) are vertical multistage
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming. Entirely in AISI
316 stainless steel for sea water and special applications.
Design Features
- Impellers, shaft, diffusors, intermediate chambers, outer liner and pump
base in AISI 316 stainless steel
- Pump head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- For the version "F" VLRXs, round DN 32 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure: 25 bar (max. liquid temperature 40 C)
- Maximum inlet pressure:
VLRX 4- 20
= 6 bar
VLRX 4- 30 - VLRX 4-100
= 10 bar
VLRX 4-120 - VLRX 4-260
= 15 bar
- Minimum suction head:
Please refer to NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer
CODE

Motor
Power

MODEL

HP

VOLTAGE

Amp.

VICTAULIC VERSION AVAILABLE

F. Q

kW

E3730010 VLRX 4- 20
E3730020 VLRX 4- 20

FM
FT

0,50 0,37

E3730030 VLRX 4- 30
E3730040 VLRX 4- 30

FM
FT

E3730050 VLRX 4- 40
E3730060 VLRX 4- 40

FM
FT

E3730070 VLRX 4- 50
E3730080 VLRX 4- 50
E3730090 VLRX 4- 60
E3730100 VLRX 4- 60

1 ~ 230 V

2,7

3 ~ 230400 V

1,7 - 1,0

0,75 0,55

1 ~ 230 V
3 ~ 230400 V

4,0
2,5 - 1,4

16

1,00 0,75

1 ~ 230 V
3 ~ 230400 V

5,2
3,3 - 1,9

25

FM
FT

1,50 1,10

1 ~ 230 V
3 ~ 230400 V

8,0
4,3 - 2,5

35

FM
FT

1,50 1,10

1 ~ 230 V
3 ~ 230400 V

8,0
4,3 - 2,5

35

1 ~ 230 V

12

45

3 ~ 230400 V

5,9 - 3,4

L/1

40

60

80

100

120

m3 /h

2,4

3,6

4,8

6,0

7,2

19

17

15

13

28

25

22

19

13

36

33

29

25

18

44

42

37

31

23

53

50

44

38

27

61

58

51

44

32

71

67

59

50

37

90

82

72

61

46

107

99

87

73

54

PRICE

14

E3730110 VLRX 4- 80/7 F M


E3730120 VLRX 4- 80/7 F T

2,00 1,50

E3730130 VLRX 4- 80
E3730140 VLRX 4- 80

FM
FT

2,00 1,50

1 ~ 230 V
3 ~ 230400 V

12
5,9 - 3,4

E3730150 VLRX 4-100

FT

3,00 2,20

3 ~ 230400 V

8,3 - 4,8

E3730160 VLRX 4-120

FT

3,00 2,20

3 ~ 230400 V

8,3 - 4,8

E3730170 VLRX 4-140

FT

4,00 3,00

3 ~ 230400 V

10,9 - 6,3

124

116

102

85

63

E3730180 VLRX 4-160

FT

4,00 3,00

3 ~ 230400 V

10,9 - 6,3

142

132

116

97

72

VLRX 4-190
VLRX 4-190

FT
FT

5,50 4,00

170

157

138

114

86

VLRX 4-220
VLRX 4-220

FT
FT

196

181

160

131

101

VLRX 4-240
VLRX 4-240

213

198

175

143

110

E3730220 VLRX 4-260


E3730240 VLRX 4-260

230

231

189

156

120

E3730190
E3730250
E3730200
E3730260
E3730210
E3730230

3 ~ 230400 V
3 ~ 400690 V

13,8 - 8,0

5,50 4,00

3 ~ 230400 V
3 ~ 400690 V

13,8 - 8,0

FT
FT

7,50 5,50

3 ~ 230400 V
3 ~ 400690 V

12,4 - 21,5

FT
FT

7,50 5,50

3 ~ 230400 V
3 ~ 400690 V

12,4 - 21,5

57

Discharge head
in meters

45

VLRX 4
H

3/8"

3/8"

75

3/4"

60
100
156
250

3/8"

20

32
78
100
140

n4 holes 18

104
180
210

13,5
n. 4 holes

- Power ( Kw ) and efficiency (

%) refer to one stage

Net Weight
kg

Dimensions mm
Model

VLRX 4 - 20 F
VLRX 4 - 30 F
VLRX 4 - 40 F
VLRX 4 - 50 F
VLRX 4 - 60 F
VLRX 4 - 80/7 F
VLRX 4 - 80 F
VLRX 4 - 100 F
VLRX 4 - 120 F
VLRX 4 - 140 F
VLRX 4 - 160 F
VLRX 4 - 190 F
VLRX 4 - 220 F
VLRX 4 - 240 F
VLRX 4 - 260 F

250
277
308
335
362
435
435
489
543
601
655
761
842
923
977

215
215
245
245
245
255
255
280
280
300
300
325
325
390
390

465
492
553
580
607
690
690
769
823
901
955
1086
1167
1313
1367

158
158
170
170
170
180
180
180
180
196
196
218
218
300
300

168
168
203
203
203
205
205
205
205
235
235
256
256
350
350

58

26
27
29
31
32
39
39
42
43
49
49
61
63
87
89

SURFACE PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX 8s (Version F with round flanges) are vertical multistage
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming. Entirely in AISI
316 stainless steel for sea water and special applications.
Design Features
- Impellers, shaft, diffusors, intermediate chambers, outer liner and pump
base in AISI 316 stainless steel
- Pump head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- For the version "F" VLRXs, round DN 32 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure: 25 bar (max. liquid temperature 40 C)
23 bar (max. liquid temperature 120 C)
- Maximum inlet pressure:
VLRX 8-20 - VLRX 8-30
= 6 bar
VLRX 8-40 - VLRX 8-200
= 10 bar
- Minimum suction head:
Please refer to NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer

CODE

Motor
Power

MODEL

HP

kW

VOLTAGE

Amp.

F. Q

VICTAULIC VERSION AVAILABLE

L/1

50

100

150

175

200

m /h

10,5

12

PRICE
3

VLRX 8 - 20 F M
VLRX 8 - 20 F T

0,75

1 ~ 230 V
3 ~ 230 400 V

5,2
3,3-1,9

25

21

20

18

15

13

E4730030
E4730040

VLRX 8 - 30 F M
VLRX 8 - 30 F T

1,5

1,1

1 ~ 230 V
3 ~ 230 400 V

8
4,3-2,5

35

32

30

27

23

19

E4730050
E4730060

VLRX 8 - 40 F M
VLRX 8 - 40 F T

1,5

1 ~ 230 V
3 ~ 230 400 V

12
5,9-3,4

45

42

40

35

30

26

E4730070

VLRX 8 - 50 F T

2,2

3 ~ 230 400 V

8,8-5,1

53

50

44

38

32

E4730080

VLRX 8 - 60 F T

2,2

3 ~ 230 400 V

8,8-5,1

64

60

52

45

39

E4730090

VLRX 8 - 80 F T

3 ~ 230 400 V

11,8-6,8

85

80

70

60

52

E4730100
E4730110

VLRX 8 - 100 F T
VLRX 8 - 100 F T

5,5

3 ~ 230 400 V
3 ~ 400 690 V

16,8-9,7

106

100

88

76

65

E4730120
E4730130

VLRX 8 - 120 F T
VLRX 8 - 120 F T

5,5

3 ~ 230 400 V
3 ~ 400 690 V

16,8-9,7

127

119

104

90

77

E4730140
E4730150

VLRX 8 - 140 F T
VLRX 8 - 140 F T

7,5

5,5

3 ~ 230 400 V
3 ~ 400 690 V

21,5-12,4

149

130

122

105

92

E4730160
E4430170

VLRX 8 - 160 F T
VLRX 8 - 160 F T

7,5

5,5

3 ~ 230 400 V
3 ~ 400 690 V

21,5-12,4

171

160

138

120

104

E4730180
E4730190

VLRX 8 - 180 F T
VLRX 8 - 180 F T

10

7,5

3 ~ 230 400 V
3 ~ 400 690 V

28-16,4

193

181

160

135

120

E4730200
E4730210

VLRX 8 - 200 F T
VLRX 8 - 200 F T

10

7,5

3 ~ 230 400 V
3 ~ 400 690 V

28-16,4

214

200

175

153

132

59

Discharge head
in meters

E4730010
E4730020

VLRX 8
Version with round flanges
PN10 DIN 2534/ISO 7005-2

80

3/4"

13,5 n4 holes

77
130
190
280

110

150

1B

48

66,5

19

215
245

Version with round flanges


PN10 DIN 2534/ISO 7005-2
H

3/4"

- Power ( Kw ) and efficiency (

%) refer to one stage

D3

Net Weight
kg

Dimensions mm
80

Model

13,5 n4 holes

77
130
190
280

110

150

48
1B

215
245

66,5

19

VLRX 8 - 20 F
VLRX 8 - 30 F
VLRX 8 - 40 F
VLRX 8 - 50 F
VLRX 8 - 60 F
VLRX 8 - 80 F
VLRX 8 - 100 F
VLRX 8 - 120 F
VLRX 8 - 140 F
VLRX 8 - 160 F
VLRX 8 - 180 F
VLRX 8 - 200 F

D3

745
805
865
925

237
237
265
265
265
315
335
335
385
385
385
385

1130
1190
1250
1310

160
160
185
185
185
200
200
200
260
260
260
260

131
131
130
130
130
140
140
140
185
185
185
185

300
300
300
300

60

33
35
43
45
46
54
55
59
80
81
85
86

SURFACE PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX 16s (Version F with round flanges) are vertical multistage
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming. Entirely in AISI
316 stainless steel for sea water and special applications.
Design Features
- Impellers, shaft, diffusors, intermediate chambers, outer liner and pump
base in AISI 316 stainless steel
- Pump head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- For the version "F" VLRXs, round DN 32 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure:
VLRX 16/30-2 - VLRX 16/80 16 bar
VLRX 16/100 - VLRX 16/160 25 bar
VLRX16/100 - VLRX 16/160 23 bar

- Maximum inlet pressure:


VLRX 16-30/2 - VLRX 16-80
VLRX 16-40
- VLRX 16-160

( max temp 85 )
( max temp 120 )

= 6 bar
= 10bar

- Minimum suction head:


Please refer to NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer

CODE

MODEL

Motor
Power

VOLTAGE

Amp.

VICTAULIC VERSION AVAILABLE

L/1

100

200

250

300

350

m3 /h

12

15

18

21

PRICE

kW

E5730010 VLRX 16 - 30/2F T

2,2

3 ~ 230 400 V

8,8-5,1

29

27

26

22

18

E5730020 VLRX 16 - 30 F T

3 ~ 230 400 V

11,8-6,8

43

40

37

32

27

E5730030 VLRX 16 - 40 F T
E5730040 VLRX 16 - 40 F T

5,5

3 ~ 230 400 V
3 ~ 400 690 V

16,8-9,7

58

54

52

44

37

E5730050 VLRX 16 - 50 F T
E5730060 VLRX 16 - 50 F T

7,5

5,5

3 ~ 230 400 V
3 ~ 400 690 V

21,5-12,4

72

68

65

56

46

E5730070 VLRX 16 - 60 F T
E5730080 VLRX 16 - 60 F T

7,5

5,5

3 ~ 230 400 V
3 ~ 400 690 V

21,5-12,4

87

81

78

68

58

E5730090 VLRX 16 - 70 F T
E5730100 VLRX 16 - 70 F T

10

7,5

3 ~ 230 400 V
3 ~ 400 690 V

28-16,4

101

95

90

80

67

E5730110 VLRX 16 - 80 F T
E5730120 VLRX 16 - 80 F T

10

7,5

3 ~ 230 400 V
3 ~ 400 690 V

28-16,4

116

108

102

92

76

E5730130 VLRX 16 - 100 F T


E5730140 VLRX 16 - 100 F T

15

11

3 ~ 230 400 V
3 ~ 400 690 V

40-23,5

145

136

130

118

98

E5730150 VLRX 16 - 120 F T


E5730160 VLRX 16 - 120 F T

15

11

3 ~ 230 400 V
3 ~ 400 690 V

40-23,5

174

163

156

140

118

E5730170 VLRX 16 - 140 F T


E5730180 VLRX 16 - 140 F T

20

15

3 ~ 230 400 V
3 ~ 400 690 V

50-29

204

190

184

163

140

E5730190 VLRX 16 - 160 F T


E5730200 VLRX 16 - 160 F T

20

15

3 ~ 230 400 V
3 ~ 400 690 V

50-29

232

220

208

188

159

61

Discharge head
in meters

HP

VLRX 16
H
D

D3

90

13,5 n4 fori
190
300

165

126

48
28

103

20

215
245

- Power ( Kw ) and efficiency (

%) refer to one stage

Net Weight
kg

Dimensions mm
Model
A

VLRX 16 - 30/2 F
VLRX 16 - 30 F
VLRX 16 - 40 F
VLRX 16 - 50 F
VLRX 16 - 60 F
VLRX 16 - 70 F
VLRX 16 - 80 F
VLRX 16 - 100 F
VLRX 16 - 120 F
VLRX 16 - 140 F
VLRX 16 - 160 F

460
464
509
575
620
665
710
830
920
1010
1100

62

265
315
335
385
385
385
385
495
495
495
495

725
779
844
960
1005
1050
1095
1325
1425
1505
1595

D3

185
200
200
260
260
260
260
260
260
310
310

130
140
140
185
185
185
185
185
185
230
230

140
250
250
300
300
300
300
350
350
350
350

44
48
51
74
76
82
84
128
132
173
177

ACCESSORIES FOR

VLR

CIRCULAR FLANGES PN 16
CODE

MATERIAL

DESCRIPTION

D3086KKK

Hole No.

140

100

18

11/4

150

110

18

DN40

150

110

18

1 /2

165

125

18

DN50

165

125

18

185

145

18

DN65

220

180

18

DN100

UNI
2254
UNI
2282
UNI
2254
UNI
2282
UNI
2254
UNI
2282
UNI
2282

Stainless
steel
AISI 316

140

99,2

20

11/4 DN32

N/A

MATERIAL

B7097KKK
ZB901890

B
STEEL

B7050KKK
B7075KKK
ZB901920

Kit including 2 oval flanges,


bolts and gaskets

ZA008460

SPEC

B7098KKK

To be
Threaded welded

PRICE

OVAL FLANGES
CODE

DESCRIPTION

Threaded

PRICE

Single oval flange


ZC001270

F
ZC001290

ZC001280

ZA008560

CAST
IRON

95

68

65

11

CAST
IRON

95

68

65

11

11/4

CAST
IRON

128

75

100

14

11/2

95

68

65

11

11/4

Stainless
steel

Kit including 2 oval flanges,


bolts and gaskets

stamped

AISI 316

SELECTION TABLE
DN 50

DN 65

DN 100

DN 32

PN 16

PN 16

PN 16

PN 16

PN 25

PN 16

PN 16

PN 16

VLR 4 FLANGE A
VLR 4 FLANGE F
VLR 8 FLANGE A
VLR 8 FLANGE F
VLR 16 FLANGE F

B7050KKK

B7051KKK

ZB901890

B7075KKK

ZB901920

ZA008460

11/2

11/4
AISI 316

"

VLR 30B FLANGE F

"

"
"

VLR 60B FLANGE F


VLRI 2B FLANGE A
VLRI 2B FLANGE F
VLRI 4 FLANGE A
VLRI 4 FLANGE F
VLRX 2B FLANGE A
VLRX 2B FLANGE F
VLRX 4 FLANGE A
VLRX 4 FLANGE F
These codes refer to the bare single flange, without bolts and gaskets
The accessory is optional
" The accessory is included in the pump as a standard

11/4
CAST IRON

"

VLR 2B FLANGE A
VLR 2B FLANGE F

ZA008560

21/2

ZC001280

ZC001290

DN 40

ZC001270

11/2

B7098KKK

TIPO

CODE

Notes

OVAL FLANGES

11/4

B7097KKK

KIT N. 2 CIRCULAR FLANGES


B Dimension

D3086KKK

ACCESSORY

63

"
"
"
"

CIRCULATION PUMPS
50 Hz

CIRCULATION PUMPS
SR3 CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both individual and communal
heating systems.
Design Features
-

Pump casing in GG20 cast iron


Tecnopolimer impeller
Motor sleeve and guide ring: AISI 316L stainless steel
Shaft in mild steel with hard chrome plating
Aluminium stator casing
Steel with nickel plating pump bearing
Carbon and ceramic thrust bearings
Connections: threaded
Versions: single

Motor
-

Wet rotor with internal separator sleeve


Asynchronous single phase with 3 speed operation
Provided with built in capacitor
Class H insulation
Level protection IP 44
Power supply voltage: single phase 1 x 230 V - 50 Hz
Direction of rotation: anticlockwise (motor end view)

Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Liquid temperature: from +10 C to +110 C
- Maximum operating pressure: 10 bar
- Pressure necessary at the suction point to avoid cavitation:
1,5 m (at a water temperature of 90 C)
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Civil and industrial pressurised or open tank heating
systems

1 x 230

1"

Motor
Power
W
110

0,48 1800

74

0,32 1200

44

0,19

130

0,30 1950

55

0,24 1550

40

0,18 1150

104

0,45 1850

78

0,35 1400

180

56

0,26 950

130

110

0,48 1800

83

0,37 1400

MY0701KKK SR3 25/40 1 1/2 - 180 1 x 230 1"1/2

180

1 x 230

1"

MY0706KKK SR3 25/50 1 1/2 - 180 1 x 230 1"1/2


MY0709KKK SR3 15/60 1 - 130

1 x 230

1"

Motor
Power
W
71

2,0

130
130

MY0710KKK SR3 25/60 1 1/2 - 130 1 x 230 1"1/2

130

MY0711KKK SR3 25/60 1 1/2 - 180 1 x 230 1"1/2

180

2,5

2,8

60

Pipe fittings not included

65

10

20

30

40

50

60

70

m /h 0,6

1,2

1,8

2,4

3,0

3,6

4,2

3,7
3,1
1,9

3,0
2,2
1,0

2,2
1,2

1,4 0,5
0,2

5,4
4,0
2,4

4,5
3,0
1,2

3,5
1,8
0,2

2,6
1,0

1,6

5,5
4,5
2,8

4,9
3,5
1,6

3,8
2,2
0,5

3,2
1,3

2,4 1,5
0,4

L/1'

N
Amp. (min
-1
)

2
1

130

MY0707KKK SR3 15/50 1 - 130

700

MY0700KKK SR3 25/40 1 1/2 - 130 1 x 230 1"1/2

MY0705KKK SR3 25/50 1 1/2 - 130 1 x 230 1"1/2

F.

SPEED

SPEED
3

0,27 1050

PRICE

Q
3

Altezza
manometrica
in m.c.a.

MY0708KKK SR3 15/40 1 - 130

N
Amp. (min
-1
)

(mm)

MODEL

CODE

2,8

VOLTAGE.
(V)

MY0712KKK MULTI-HEAD SR3 V 1 x 230

F.

CENTRE
DISTANCE

MODEL

Connections

CODE

VOLTAGE.
(V)

REPLACEMENT MULTI-PURPOSE HEAD FOR SR3

0,8

0,5

SR3
H (m)

P (kPa)

H (m)

P (kPa)

60

70

SR3 15/25-40
6

60

50

40

30

SR3 15/25-50
5

50

40

2
1
0

2
0,5

20

H (m)

2
0,5

(l/sec.)

10

0
5 (m3/h)

10

20

30

0
5 (m3/h)
(l/sec.)

P (kPa)

70

SR3 15/25-60
6

60

50

40

30

20

10

0
0

MODEL

2
0,5

0
5 (m3/h)

(l/sec.)

PACKING
VOLUME

OVERALL DIMENSIONS (mm)

CONNECT.

(dm3)

130

65

105,4

135

46,6

76,7

2,75

SR3 25/40 1 1/2 - 130

1 1/2

130

65

105,4

135

46,6

76,7

2,75

SR3 25/40 1 1/2 - 180

1 1/2

180

90

105,4

135

46,6

76,7

3,55

130

65

105,4

135

46,6

76,7

2,75

SR3 25/50 1 1/2 - 130

1 1/2

130

65

105,4

135

46,6

76,7

2,75

SR3 25/50 1 1/2 - 180

1 1/2

180

90

105,4

135

46,6

76,7

3,55

130

65

105,4

135

46,6

76,7

2,75

SR3 25/60 1 1/2 - 130

1 1/2

130

65

105,4

135

46,6

76,7

2,75

SR3 25/60 1 1/2 - 180

1 1/2

180

90

105,4

135

46,6

76,7

3,55

SR3 15/40 1 - 130

SR3 15/50 1 - 130

SR3 15/60 1 - 130

66

WEIGHT (kg)
net

gross

2,7

2,8

2,7

2,8

2,8

2,9

CIRCULATION PUMPS
R2S 25 CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both individual and communal
heating systems.
Design Features
-

Pump casing in GG20 cast iron


Motor sleeve and guide ring: AISI 304 stainless steel
Shaft in AISI 431 stainless steel
Aluminium stator casing
Graphite pump bearing
Ceramic thrust bearing
Connections: threaded
Versions: single

Motor
-

Wet rotor with internal separator sleeve


Asynchronous single phase with 3 speed operation
Provided with built in capacitor
Class F insulation
Level protection IP 42
Power supply voltage: single phase 1 x 230 V - 50 Hz
Direction of rotation: clockwise (motor end view)

Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Liquid temperature: from +10 C to +110 C
- Maximum operating pressure: 10 bar
- Pressure necessary at the suction point to avoid cavitation:
2 m (at a water temperature of 90 C)
- The pump must be installed with the driving shaft in a
horizontal position

3,0

Motor
Power
W

180

F.

SPEED

(mm)

B0725KKK R2S 25 - 70 1 x 230 1"1/2

CENTRE
DISTANCE

MODEL

Connections

CODE

VOLTAGE.
(V)

Applications
- Civil and industrial pressurised or open tank heating
systems

3
2
1

140
110
86

n
Amp.
(rpm )

0,70
0,59
0,43

Pipe fittings not included

67

2400
2000
1400

l/1'

20

30

40

50

60

80

m3/h

1,2

1,8

2,4

3,0

3,6

4,8

5,8
3,6
1,7

5,5
2,9
1

4,9
2,1

4,2
1,5

3,4
0,8

PRICE

Altezza
manom.
in m.c.a.

R2S 25
H (m)

BA010101 / 03.09.01

P (kPa)

70

R2S 25-70
6

60

50

40

30

20

10

0
0
0

MODEL

R2S 25 - 70

(l/sec.)

0,5

PACKING
VOLUME

OVERALL DIMENSIONS (mm)

CONNECT.

1"1/2

0
5 (m3/h)

WEIGHT (kg)

(dm3)

net

gross

180

90

100

135

46

75

4,5

2,6

2,8

68

OPTIONAL
ACCESSORIES
PIPE FITTING
KIT

CIRCULATION PUMPS
R2S CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both individual and communal
heating systems.
Design Features
- Pump casing in GG20 cast iron
- Glass-fibre reinforced Noryl impeller
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Connections: threaded 40 series
flanged 42 series
- Versions: single

R2S

Motor
- Wet rotor with internal separator sleeve
- Asynchronous single phase
- 3 speed operation
- Provided with built in capacitor
- Class F insulation
- Level protection IP 42
- Power supply voltage: single phase 1 x 230 V - 50 Hz
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Liquid temperature: from +10 C to +110 C
- Maximum operating pressure: 10 bar
- Pressure necessary at the suction point to avoid cavitation:
2 m (at a water temperature of 90 C)
- The pump must be installed with the driving shaft in a
horizontal position

R2S...F

20

30

40

60

80

100

R2S 32 - 60

1 x 230

2"

180

5,0

3
2
1

143
121
110

0,8
0,7
0,6

2600
2300
1500

4,7
4,5
4,2

4,4
4,0
3,4

4,2
3,6
3,0

2,9
2,3
1,6

1,8

N8010000

R2S 32 - 90

1 x 230

2"

180

5,0

3
2
1

1,1
0,9
0,8

2600
2100
1400

6,6
4,9
2,0

4,8
2,6
0,4

2,6
0,2

R2S 40 - 60

1 x 230

2"

180

5,0

0,9
0,8
0,7

2700
2400
1550

7,8
6,8
4,7
4,9
4,7
4,0

7,3
6,0
3,2

N8010002

231
198
181
165
159
143

0,2

N8010001

4,7
4,4
3,6

4,4
4,1
3,2

3,9
3,4
2,5

3,3
2,8
1,8

2,4
2,1
1,2

N8010003

R2S 40 - 90 1 x 230

2"

180

7,0

7,8
3,9
2,3

7,5
3,0
1,7

6,5
1,7
1,0

5,6
1,2
0,8

4,7
0,9
0,4

R2S 42 - 60 F 1 x 230

DN 40
250
PN 6

5,0

N8010005

R2S 42 - 90 F 1 x 230

DN 40
250
PN 6

7,0

2600
1900
1300
2600
2300
1600
2250
1800
1600

8,3
5,0
3,4

N8010004

1,2
1,1
0,9
0,9
0,8
0,7
1,2
1,1
0,9

4,9
4,7
4,0
7,9
6,7
3,8

4,6
4,3
3,6
7,5
5,7
2,9

4,4
4,0
3,2
7,1
4,7
2,0

3,8
3,3
2,2
6,4
2,8
1,2

2,9
2,4
1,3
5,5
1,4
0,7

2,0
1,5
0,2
4,4
0,8
0,4

F.

3
2
1
3
2
1
3
2
1
3
2
1

275
253
187
165
159
143
275
253
187

Pipe fittings and counterflanges not included

69

n
Q
(rpm)

150
PRICE

m /h

Discharge Head in meters

MODEL

(mm)

Amp.

CODE

Motor
Power
W

l/1'

SPEED

CENTRE
DISTANCE

Connections

VOLTAGE.
(V)

Applications
- Civil and industrial pressurised or open tank heating
systems

1,2

1,8

2,4

3,6

4,8

6,0

9,0

2,4

1,4

R2S
H (m)

P (kPa)

P01024244 / 10.07.01

H (m)

70

P01024547 / 11.07.01

10
9

R2S 32-60

R2S 32-90

P (kPa)

100
90

60

80

50

70

40

60

5
3

30

2
1

10

0
1

0,5

H (m)

1,5

20

10

6 (m3/h)

(l/sec.)

50
40

1,5

(l/sec.)

P01019193 / 08.05.01

P (kPa)

R2S 40-90

80

70
60

50

4
20

40

30

10

20
10

1
0

0
0

4
1

0,5

6
1,5

H (m)

8
2

50

40

0,5

4
1

6
1,5

2,5

0
10 (m3/h)
(l/sec.)

P (kPa)

90

80

70
60

50
40

30

20

10

0
0
0

(l/sec.)

2,5

0,5

4
1

6
1,5

8
2

9
2,5

0
10 (m3/h)
(l/sec.)

R2S 40......

CONNECT.

1,5

P010273 / 19.07.01

0
10 (m3/h)

R2S 42-90F

R2S 42....F

MODEL

0,5

20

10

30

H (m)

60

P (kPa)

R2S 42-60F

(l/sec.)

2,5

P19701.3V / 30.07.01

10 (m3/h)

100
90

6
30

0
6 (m3/h)

0,5

H (m)

R2S 40-60

10

60

30

P (kPa)

P010241 / 10.07.01

40

20

50

PACKING
VOLUME

OVERALL DIMENSIONS (mm)

WEIGHT (kg)

net

gross

4,8

5,0

4,8

5,0

100

5,3

5,5

120

100

5,3

5,5

190

120

100

11

7,5

7,7

190

120

100

11

7,5

7,7

R2S 32 - 60

A
180

B
90

C
125

D
165

E
120

F
100

R2S 32 - 90

180

90

125

165

120

100

R2S 40 - 60

180

90

135

175

120

R2S 40 - 90

180

90

135

175

R2S 42 - 60 F

DN 40

250

125

135

R2S 42 - 90 F

DN 40

250

125

135

70

(dm 3)

ACCESSORIES

ON REQUEST
page 120

CIRCULATION PUMPS
R2SD CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both individual and communal
heating systems.
Design Features
- Pump casing in GG20 cast iron
- Glass-fibre reinforced Noryl impeller
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Connections: threaded
flanged (R2SD 40-50 F)
- Versions: twin
Motor
- Wet rotor with internal separator sleeve
- Asynchronous single phase
- 3 speed operation
- Provided with built in capacitor
- Class F insulation
- Level protection IP 42
- Power supply voltage: single phase 1 x 230 V - 50 Hz
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Liquid temperature: from +10 C to +110 C
- Maximum operating pressure: 10 bar
- Pressure necessary at the suction point to avoid cavitation:
2 m (at a water temperature of 90 C)
- The pump must be installed with the driving shaft in a
horizontal position

20

30

40

60

80

100

150

m3/h

1,2

1,8

2,4

3,6

4,8

6,0

9,0

R2SD 32 - 60 1 x 230

2"

180

3
2
1

143
121
110

0,8
0,7
0,6

2600
2300
1450

5,2
4,8
4,5

4,8
4,5
4,0

4,4
4,0
3,5

3,0
2,6
2,0

0,9
0,6

2"

180

3
2
1

231
198
181

1,1
0,9
0,8

2600
2000
1400

8,0
7,0
4,8

7,5
6,1
3,4

6,9
5,0
2,2

5,4
2,8
0,8

3,2
0,9

1,0

N8010007 R2SD 32 - 90 1 x 230

DN40
N8010008 R2SD 42 - 60F 1 x 230 PN6 255
PN10

3
2
1

165
159
143

0,9
0,8
0,7

2400
1800
1150

5,1
4,8
4,1

4,9
4,5
3,6

4,6
4,2
3,1

4,0
3,4
2,1

3,2
2,4
1,3

2,1
1,4
0,6

DN40
N8010009 R2SD 42 - 90F 1 x 230 PN6 255
PN10

3
2
1

275
253
187

1,2
1,1
0,9

2400
1600
1100

7,7
6,3
3,6

7,4
5,2
2,7

7,1
4,1
2,0

6,4
2,3
1,1

5,5
1,2
0,7

4,4
0,7

F.

Pipe fittings and counterflanges not included

71

n
Q
(rpm)

PRICE

Discharge Head
in meters

N8010006

MODEL

(mm)

Amp.

CODE

Motor
Power
W

l/1'

SPEED

CENTRE
DISTANCE

Connections

VOLTAGE.
(V)

Applications
- Civil and industrial pressurised or open tank heating
systems

1,2

R2SD
H (m)

H (m)

P (kPa)

P230001b / 07.09.01

P22601b / 07.09.01

60

R2SD 32-60

R2SD 32-90

80

70

40
30

10

1
0

4
1

0,5

H (m)

P22302b / 31.08.01

30

20

10
0

(l/sec.)

P (kPa)

H (m)

60

0
6 (m3/h)

0,5

1,5

P22301e / 28.08.01

R2SD 42-60F

R2SD 42-90F

50

40

0
5 (m3/h)

50

20

60

5
3

40

4
3

20

0
0

0,5

6
1,5

20
10

0
0

(l/sec.)

30

0
8 (m3/h)

1,5

8
2

0
9 (m3/h)
2,5 (l/sec.)

R2SD 42 - 60 F
R2SD 42 - 90 F

OVERALL DIMENSIONS (mm)

CONNECT.

3
1

0,5

R2SD 32-60
R2SD 32-90

MODEL

80

40

2
10

90

50

30

P (kPa)

60

5
3

(l/sec.)

70

7
4

90

8
50

P (kPa)

PACKING WEIGHT (kg)


VOLUME
(dm3)
net gross

R2SD 32 - 60

180

105

135

175

235

100

14,2

9,9

10,1

R2SD 32 - 90

180

105

135

175

235

100

14,2

9,9

10,1

R2SD 42 - 60 F DN 40
DN- 40N 10

250

145

135

195

245

100

21,5

15,7

15,9

R2SD 42 - 90 F DN 40
DN- 40
PN 10

250

145

135

195

245

100

21,5

15,7

15,9

72

ACCESSORIES

ON REQUEST
page 120

CIRCULATION PUMPS
R2X - R2B CIRCULATION PUMPS
FOR DOMESTIC WATER
Circulation pumps of the wet rotor type are suitable for the
circulation of hot sanitary water in heating systems.

Materials
- Pump casing
- Impeller
- Motor liner
- Seal ring
- Shaft
- Motor casing
- Pump bearing
- Fifth wheel

R2X Series

R2B Series

AISI 304 S/steel in Al casing


AISI 304 S/steel
AISI 304 S/steel
AISI 304 S/steel
AISI 431 S/steel
Alluminium
Graphite
99% Alumina

B10 Brass (G CuSn10)


AISI 304 S/steel
AISI 304 S/steel
AISI 304 S/steel
AISI 431 S/steel
Alluminium
Graphite
99% Alumina

Motor
- Wet rotor with liner
- Asynchronous single phase
- One speed operation
- Provided with built in capacitor
- Class F insulation
- Level protection IP 42
- Power supply voltage: single phase 1 x 230 V - 50 Hz
- Direction of rotation (motor end view):
R2X series - anticlockwise
R2B series - anticlockwise
Restrictions
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Linestone-free water (if water exceeds 35 F a softener
device must be installed)
- Suggested water temperature max 60 C
- The pump must be installed with the driving shaft in a
horizontal position (see side picture)

10

20

30

40

50

60

80

m3/h

0,6

1,2

1,8

2,4

3,0

3,6

4,8

B1641600

R2X 20 - 18 1 x 230 1"1/4

150

3,0

75

0,36

2200

1,7

1,3

0,7

B1643600

1/4
R2X 20 - 30 1 x 230 1"

150

3,0

87

0,42

2000

2,6

2,0

1,3

0,3

180

5,0

143

0,77

2600

5,3

4,9

4,6

4,1

3,5

2,7

0,5

180

5,0

231

1,1

2600

8,2

7,6

7,1

6,6

6,0

5,2

3,0

F.

n
(rpm) Q

PRICE

1"1/2

N8010014 R2B 30 - 60
1 x 230
N8010010 R2B 32 - 60

2"

N8010015 R2B 30 - 90

1"1/2
1 x 230

Discharge Head
in meters

MODEL

(mm)

Amp.

CODE

Motor
Power
W

l/1'

SPEED

CENTRE
DISTANCE

Connections

VOLTAGE
(V)

Applications
- Sanitary hot water circulation systems, heating and
conditioning systems

N8010011 R2B 32 - 90

2"

N8010012 R2B 40 - 60 1 x 230

2"

180

5,0

165

0,88

2700

5,3

5,0

4,8

4,5

4,2

3,8

3,2

N8010013 R2B 40 - 90 1 x 230

2"

180

7,0

275

1,21

2600

7,6

7,2

6,8

6,4

6,1

5,8

5,1

Pipe fittings not included

73

R2X - R2B

H (m)

H (m)

P (kPa)

P31001 / 08.11.01

P31101a / 07.11.01

10

70

R2B 30 / 32-60

R2B 30 / 32-90

P (kPa)

100
90

60

50

40

30
20

30

20

10

2
1

10

0
0

0,5

H (m)

P (kPa)

40

30

2
1

10

0
0

4
1

0,5

6
1,5

8
2

50
40

R2X 20 - 18
R2X 20 - 30
R2B 30 - 60
R2B 32 - 60
R2B 30 - 90
R2B 32 - 90
R2B 40 - 60
R2B 40 - 90

0,5

0
8 (m3/h)

1,5

(l/sec.)

P (kPa)

P010265 / 17.07.01

90

80

70

60

50

40

30

20

10

4
1

0,5

R2X

MODEL

R2B 40-90

(l/sec.)

2,5

10 (m3/h)

20

5
4

H (m)

50

60

R2B 40-60

60

70

(l/sec.)

1,5

P010262 / 17.07.01

80

0
6 (m3/h)

6
1,5

7
2

9
2,5

0
10 (m3/h)
(l/sec.)

R2B

OVERALL DIMENSIONS (mm)

CONNECT.

PACKING WEIGHT (kg)


VOLUME
(dm3)
net gross

1/4

1"

150

90

119

154

120

80

4,5

2,0

2,2

1"1/2
2
1"1/2
2
2
2

180
180
180
180
180
180

90
90
90
90
90
90

125
125
125
125
135
135

165
165
165
165
175
175

120
120
120
120
120
120

100
100
100
100
100
100

7
7
7
7
7
7

5,1
5,1
5,1
5,1
5,6
5,6

5,3
5,3
5,3
5,3
5,8
5,8

74

ACCESSORIES

ON REQUEST
(page 128)

CIRCULATION PUMPS
R2C - R4C CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 40 - PN 6/10
- Versions: single
Motor
- Asynchronous wet rotor with internal separator sleeve, 2
pole (R2C) or 4 pole (R4C)
- Two speed operation
- Provided with built in capacitor (single phase models)
- Class F insulation
- Level of protection IP 42
- Power supply voltage: single or three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems

MODEL

B3420374
B3420352

VOLTAGE
SPEED
(V)

1 x 230
R4C 40 - 30

3 x 230

B3420350

3 x 400

B3420624

11 x 2300

B3420602

R2C 40 - 60

3 x 230

B3420600

3 x 400

B3421224

1 x 230

B3421202
B3421200

R2C 40 - 120

3 x 230
3 x 400

Motor
n
Power
Amp. (rpm)
W
max min.

2
1
2
1

250
180
200
108

210
110
150
68

1,14
1,05
1,20
0,48

1450
1320
1410
1190

2
1

200
108

150
68

0,70
0,28

1410
1190

2
1
2
1

337
290
305
202

250
170
210
132

1,54
1,40
1,34
0,64

2760
2470
2810
2520

2
1

305
202

210
132

0,77
0,37

2810
2520

2
1
2
1

540
450
550
370

390
280
335
245

2,46
2,20
1,85
1,10

2710
2150
2710
2110

2
1

550
370

335
245

1,07
0,63

2710
2110

COUNTERFLANGES NOT INCLUDED

75

l/1'

50

100

150

200 250

m3/h

12

15

3,3
2,8

3,1
2,6

2,6
2,0

2,0
1,2

1,2
0,5

0,3

6,5
5,5

6,2
4,8

5,4
3,7

4,1
2,2

2,7
0,8

1,0

11,8 11,2
9,1 7,3

9,9
5,7

8,3
3,8

6,8
2,3

4,7
0,8

300

F. Q

PRICE
18

12
12
-

Discharge Head
in meters

CODE

20
-

2,2

R2C-R4C 40

B2

B1
B5

H1

D6
D3

D1
D2
D4

H2
H3

G 1/4"

B3

B4

L1

D5
D7

OVERALL DIMENSIONS (mm)

MODEL
D1

D2

D3

D4

D5 nD5 D6 D7 nD7 H1

H2

H3

WEIGHT (kg)
L1

B1

B2

B3

B4

B5

net

gross

PACKING
VOLUME
(dm3)

R4C 40 -

30

42

80 100 150

14

110

19

67 218 285 250 75

95

75

90

96 M12

14

16

0,030

R2C 40 -

60

42

80 100 150

14

110

19

67

95

75

90

96 M12

14

16

0,030

R2C 40 - 120

42

80 100 150

14

110

19

67 218 285 250

95

75

90

96 M12

15

17

0,030

218 285 250 75

76

75

CIRCULATION PUMPS
R2C - R4C CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 50 - PN 6/10
- Versions: single
Motor
- Asynchronous wet rotor with internal separator sleeve, 2
pole (R2C) or 4 pole (R4C)
- Two speed operation
- Provided with built in capacitor (single phase models)
- Class F insulation
- Level of protection IP 42
- Power supply voltage: single or three phase (except for
mod. R2C 50-180)
- Direction of rotation: anticlockwise (motor end view):
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems

MODEL

B3520374
B3520352

1 x 230
R4C 50 - 30

3 x 230

B3520350

3 x 400

B3540674

1 x 230

B3540652

R4C 50 - 60

3 x 230

B3540650

3 x 400

B3520624

1 x 230

B3520602

R2C 50 - 60

3 x 230

B3520600

3 x 400

B3541224

1 x 230

B3541202

R2C 50 - 120

B3541200

3 x 400

B3541802
B3541800

3 x 230

3 x 230
R2C 50 - 180

3 x 400

2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1

Motor
n
Power
Amp. (rpm)
W
max min.
275
225
230
132
230
132
450
420
425
290
425
290
390
350
390
243
390
243
1020
950
885
650
885
650
1330
940
1330
940

235
130
160
90
160
90
290
195
220
140
220
140
250
190
240
145
240
145
620
450
480
370
480
370
730
530
730
530

1,30
1,27
1,28
0,58
0,74
0,33
2,10
2,25
1,91
1,04
1,10
0,60
1,80
2,25
1,65
0,75
0,95
0,43
4,60
4,50
3,02
2,04
1,75
1,18
4,42
2,85
2,55
1,65

1380
1150
1390
1170
1390
1170
1380
1120
1390
1170
1390
1170
2700
2230
2700
2280
2700
2280
2800
2500
2700
2280
2700
2050
2700
2280
2760
2260

COUNTERFLANGES NOT INCLUDED

77

F.

l/1'

50

100

200

300 400

500

m3/h

12

18

3,0
2,5

2,8
2,2

2,6
1,9

2,0
1,0

1,0
0,2

5,6
5,0

5,4
4,5

5,2
3,9

4,2
2,5

2,9
1,0

6,9
5,2

6,7
4,8

6,3
4,1

4,7
2,4

2,2
0,4

11,6 11,2 10,8


10,1 9,1 8,5

8,4
6,2

7,2
4,0

4,5
2,0

1,4

17,0 16,0 14,8 12,0


14,0 12,4 10,6 7,5

9,0
4,0

4,3

0,2

PRICE
24

30

12
20
12
-

Discharge Head
in meters

CODE

VOLTAGE
SPEED
(V)

1,0

35
-

R2C-R4C 50

B2

B1
B5

H1

D6
D3

D1
D2
D4

H2
H3

G 1/4"

B3

B4

L1

D5
D7

OVERALL DIMENSIONS (mm)

MODEL
D1

D2

D3

D4 D5 nD5 D6 D7 nD7 H1

H2

H3

WEIGHT (kg)
L1

B1

B2

B3

B4

B5

75

95

75

net

gross

PACKING
VOLUME
(dm3)

R4C 50 -

30

50

90

110 165

14

125

19

75

220 295 280

102

96 M12

17

19

0,030

R4C 50 -

60

50

90

110 165

14

125

19

75

255 330 280 101 115 101 102

96 M12

23

26

0,054

R2C 50 -

60

50

90

110 165

14

125

19

75

220 295 280

102

96 M12

17

19

0,030

R2C 50 - 120

50

90

110 165

14

125

19

75

255 330 280 101 115 101 102

96 M12

24

26

0,054

R2C 50 - 180

50

90

110 165

14

125

19

75

265 340 280 101 115 101 102

96 M12

25

28

0,054

78

75

95

75

CIRCULATION PUMPS
R2C - R4C CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 65 - PN 6/10
- Versions: single
Motor
- Asynchronous wet rotor with internal separator sleeve, 2
pole (R2C) or 4 pole (R4C)
- Two speed operation
- Class F insulation
- Level of protection IP 42
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems

MODEL

Motor
n
Power
Amp. (rpm)
W
max min.

3 x 230

2
1

305 210
185 120

1,52
0,70

1330
1010

B3620350

3 x 400

2
1

305 210
185 120

0,87
0,40

1330
1010

B3640652

3 x 230

2,55
1,30
1,47
0,55
1,70
1,02
0,98
0,59
4,42
2,85
2,55
1,65
6,65
4,50
3,85
2,60

1400
1190
1400
1190
2780
2270
2780
2270
2760
2260
2760
2260
2810
2420
2810
2420

B3620352
R4C 65 - 30

R4C 65 - 60
3 x 400

B3640650

3 x 230

B3620602
R2C 65 - 60

3 x 400

B3620600

3 x 230

B3641202
R2C 65 - 120

3 x 400

B3641200

3 x 230

B3641802
R2C 65 - 180
B3641800

3 x 400

2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1

540
370
540
370
478
328
478
328
1330
940
1330
940
1970
1510
1970
1510

280
175
280
175
302
208
302
208
730
530
730
530
950
720
950
720

COUNTERFLANGES NOT INCLUDED

79

l/1'

100

200

300

400

600

800

m3/h

12

18

24

36

48

2,9
2,4

2,8
2,1

2,4
1,6

1,9
1,0

1,3
0,5

0,1

5,5
5,0

5,4
4,2

4,8
3,4

4,2
2,5

3,2
1,4

1,0

6,3
5,1

6,0
4,1

5,3
3,2

4,2
2,1

2,6
0,9

11,8 11,4 10,9 10,1


9,5 9,0 7,9 6,9

8,6
4,5

5,7
2,7

18,0 16,9 15,2 12,7


15,5 13,6 11,0 8,8

9,4
6,3

2,5
0,4

PRICE

Discharge Head
in meters

CODE

VOLTAGE
SPEED
(V)

1,9

R2C-R4C 65

B2

B1
B5

H1

D6
D3

D1
D2
D4

H2
H3

G 1/4"

B3

B4

L1

D5
D7

OVERALL DIMENSIONS (mm)

MODEL
D1

D2

D3

D4 D5 nD5 D6 D7 nD7 H1

H2

H3

L1

WEIGHT (kg)

B1

B2

B3

B4

B5

net

gross

PACKING
VOLUME
(dm3)

R4C 65 -

30

65

110 130 185

14

145

19

82

230 312 340

75

95

75

124

96

M12

23

26

0,054

R4C 65 -

60

65

110 130 185

14

145

19

82

265 347 340

75

95

75

124

96

M12

29

32

0,054

R2C 65 -

60

65

110 130 185

14

145

19

82

230 312 340 101 115 101 124

96

M12

23

25

0,054

R2C 65 - 120

65

110 130 185

14

145

19

82

265 347 340 101 115 101 124

96

M12

30

33

0,054

R2C 65 - 180

65

110 130 185

14

145

19

82

286 368 340 101

96

M12

33

36

0,054

80

115 101 124

CIRCULATION PUMPS
R2C - R4C CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 80
- PN 10 version are available on request
- Versions: single
Motor
- Asynchronous wet rotor with internal separator sleeve, 2
pole (R2C) or 4 pole (R4C)
- Two speed operation
- Class F insulation
- Level of protection IP 42
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems

MODEL

VOLTAGE
SPEED
(V)

Motor
Power
Amp.
W
max min.

n
(rpm)

3 x 230

2
1

390 270
273 185

1,82
1,00

1405
1200

B3840350

3 x 400

2
1

390 270
273 185

1,05
0,58

1405
1200

B3840652

3 x 230

2
1

975 470
710 290

4,75
2,50

1400
1200

B3840650

3 x 400

2
1

975
710

470
290

2,75
1,45

1400
1200

B3841202

3 x 230

2
1

1970
1510

950
720

6,65
4,50

2810
2420

B3841200

3 x 400

2
1

1970
1510

730 3,85
530 2,60

2810
2420

B3841802

3 x 230

2
1

2520 2320
1780 1040

7,60
5,40

2800
2450

3 x 400

2
1

2520 2320
1780 1040

4,40
3,10

2800
2450

B3840352
R4C 80 - 30

R4C 80 - 60

R2C 80 - 120

R2C 80 - 180
B3841800

COUNTERFLANGES NOT INCLUDED

81

l/1'

100

250

500

750 1000 1250

m3/h

15

30

45

3,7
3,1

3,6
2,8

3,2
2,2

1,9
0,7

0,2

6,0
5,4

5,9
5,2

5,7
4,8

4,7
3,2

2,9
0,9

0,8

11,2 11,0 10,8


10,2 9,6 8,8

9,8
6,9

7,8
4,7

5,0
2,2

17,8 17,5 16,7 13,1


15,2 14,6 12,8 7,4

4,6

Discharge Head
in meters

CODE

PRICE
60

75

1,3

R2C-R4C 80

B1

B2

B5

D3

H1
B3

MODEL

B4

D1
D2
D4

H2
H3

G 1/4"

L1

D5

OVERALL DIMENSIONS (mm)

PN
bar

D1

D2

D3

D4

D5

nD5

H1

H2

H3

L1

B1

B2

B3

B4

B5

WEIGHT (kg) PACKING


VOLUME
net gross (dm3)

R4C 80 -

30

80

128

150

190

18

97

266

363

360

101

115

101

130

96

M12

32

35

0,054

R4C 80 -

60

80

128

150

190

18

97

286

383

360

101

115

101

130

96

M12

36

39

0,054

R2C 80 - 120

80

128

150

190

18

97

286

383

360

101

115

101

130

96

M12

37

40

0,054

R2C 80 - 180

80

128

150

190

18

97

286

383

360

101

115

101

130

96

M12

37

40

0,054

82

CIRCULATION PUMPS
R4C CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for the
circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 100
- PN 10 versions are available on request
- Versions: single
Motor
- Asynchronous wet rotor with internal separator sleeve, 4 pole
(R4C)
- Two speed operation
- Class F insulation
- Level of protection IP 42
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems

CODE

MODEL

VOLTAGE
SPEED
(V)

3 x 230

B3040352

2
1

Motor
Power
Amp.
W
max min.
669 495
420 340

2,85
1,55

n
(rpm)

l/1'
m /h

2
1

669 495
420 340

1,65
0,90

1370
1130

B3040652

3 x 230

2
1

1235 880
810 595

5,42
2,95

1375
1120

R4C 100 - 60
1235 880
810 595

3,12
1,70

750 1000 1250 1500

15

30

45

60

75

3,7
3,0

3,4
2,6

3,0
2,0

2,3
1,2

1,4
0,1

0,1

6,0
4,6

5,7
4,2

5,2
3,5

4,7
2,7

3,8
1,6

2,6
0,3

90

1375
1120

COUNTERFLANGES NOT INCLUDED

83

Discharge Head
in meters

3 x 400

2
1

500

1370
1130

B3040350

3 x 400

250

PRICE
3

R4C 100 - 30

B3040650

1,1

R4C 100

B1

B2

B5

D3

H1
B3

B4

PN
bar

MODEL

D1
D2
D4

H2
H3

G 1/4"

L1

D5

OVERALL DIMENSIONS (mm)


D1

D2

D3

D4

D5

nD5

H1

H2

H3

L1

B1

B2

B3

B4

B5

WEIGHT (kg) PACKING


VOLUME
net gross (dm3)

R4C 100 -

30

100

148

170

210

18

107

305

412

450

101

115

101

167

144 M16

45

48

0,081

R4C 100 -

60

100

148

170

210

18

107

325

432

450

101

115

101

167

144 M16

46

49

0,081

84

CIRCULATION PUMPS
R2CD - R4CD CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for the
circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 40 - PN 6/10
- Versions: twin
Motor
- Asynchronous wet rotor with internal separator sleeve, 2 pole
(R2CD) or 4 pole (R4CD)
- Two speed operation
- Provided with built in capacitor (single phase models)
- Class F insulation
- Level of protection IP 42
- Power supply voltage: single or three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems

HYDRAULIC PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

MODEL

Motor
Power
Amp.
W
max min.

l/1'
n
(rpm)

F.

2
1

250
180

210
110

1,14
1,05

1450
1320

12

3 x 230

2
1

200
108

150
68

1,20
0,48

1410
1190

B3420250

3 x 400

2
1

200
108

150
68

0,70
0,28

1410
1190

B3420524

1 x 230

2
1

337
290

250
170

1,54
1,40

2760
2470

12

3 x 230

2
1

305
202

210
132

1,34
0,64

2810
2520

B3420500

3 x 400

2
1

305
202

210
132

0,77
0,37

2810
2520

B3421124

1 x 230

2
1

540
450

390
280

2,46
2,20

2710
2150

20

3 x 230

2
1

550
370

335
245

1,85
1,10

2710
2110

3 x 400

2
1

550
370

335
245

1,07
0,63

2710
2110

B3420252

B3420502

B3421102
B3421100

R4CD 40 - 30

R2CD 40 - 60

R2CD 40 - 120

COUNTERFLANGES NOT INCLUDED

85

50

100

150

200 250

300
PRICE

m3/h

1 x 230

B3420274

Discharge Head
in meters

CODE

VOLTAGE
SPEED
(V)

12

15

3,3
2,8

3,1
2,6

2,6
2,0

2,0
1,2

1,2
0,5

0,3

6,5
5,5

6,2
4,8

5,4
3,7

4,1
2,2

2,7
0,8

1,0

11,8 11,2
9,1 7,5

9,9
6,1

8,3
4,2

6,8
2,2

4,7
0,2

18

2,2

R2CD-R4CD 40

HYDRAULIC PERFORMANCE
WITH ONLY ONE HEAD IN OPERATION

B1
L4

B2

L5

B3

H2
H3

M
G 1/4
B4

D7

H1

B4

B5

D5
G1/8
D1
D2
D3

L2

L3
L1

D6
D4

WEIGHT (kg) PACKING


VOLUME
(dm3)
net gross

OVERALL DIMENSIONS (mm)

MODEL
D1 D2 D3

D4 D5 nD5 D6 D7 nD7 H1 H2 H3

L1 L2 L3 L4 L5

B1 B2 B3 B4 B5

R4CD 40 - 30

42

80 100 150 14

4 110 19

68 218 286 250 99 151 97 96 364 184 180 100 200 M12

27

30

0,054

R2CD 40 - 60

42

80 100 150 14

4 110 19

68 218 286 250 99 151 97 96 364 184 180 100 200 M12

27

30

0,054

R2CD 40 - 120

42

80 100 150 14

68 218 286 250 99 151 97 96 364 184 180 100 200 M12

29

32

0,054

110 19

86

CIRCULATION PUMPS
R2CD - R4CD CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for the
circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 50 - PN 6/10
- Versions: twin
Motor
- Asynchronous wet rotor with internal separator sleeve, 2 pole
(R2CD) or 4 pole (R4CD)
- Two speed operation
- Provided with built in capacitor (single phase models)
- Class F insulation
- Level of protection IP 42
- Power supply voltage: single or three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems

HYDRAULIC PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

MODEL

B3520274
B3520252

VOLTAGE
SPEED
(V)

1 x 230
R4CD 50 - 30

3 x 230

B3520250

3 x 400

B3540574

1 x 230

B3540552

R4CD 50 - 60

B3540550

3 x 400

B3520524
B3520502

3 x 230

1 x 230
R2CD 50 - 60

3 x 230

B3520500

3 x 400

B3541124

1 x 230

B3541102

R2CD 50 - 120

B3541100

3 x 400

B3541702
B3541700

3 x 230

3 x 230
R2CD 50 - 180

3 x 400

2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1

Motor
Power
Amp.
W
max min.
275
225
230
132
230
132
450
420
425
290
425
290
390
350
390
243
390
243
1020
950
885
650
885
650
1330
940
1330
940

235
130
160
90
160
90
290
195
220
140
220
140
250
190
240
145
240
145
620
450
480
370
480
370
730
530
730
530

1,30
1,27
1,28
0,58
0,74
0,33
2,10
2,25
1,91
1,04
1,10
0,60
1,80
2,25
1,65
0,75
0,95
0,43
4,60
4,50
3,02
2,04
1,75
1,18
4,42
2,85
2,55
1,65

n
(rpm)
1380
1150
1390
1170
1390
1170
1380
1120
1390
1170
1390
1170
2700
2230
2700
2280
2700
2280
2800
2500
2700
2280
2700
2050
2700
2280
2760
2260

COUNTERFLANGES NOT INCLUDED

87

F.

l/1'

50

100

200

300

400

500

m3/h

12

18

24

30

3,0
2,5

2,8
2,2

2,6
1,9

2,0
1,0

1,0
0,2

5,6
5,0

5,4
4,5

5,2
3,9

4,2
2,5

6,9
5,2

6,7
4,8

6,3
4,1

4,7
2,4

PRICE

12
20
12
-

Discharge Head
in meters

CODE

2,9
1,0

1,0

2,2
0,4

35
-

11,6 11,2 10,8


10,1 9,1 8,2

9,4
6,4

7,2
4,2

4,5
2,0

1,5

9,0
3,8

4,3

0,2

17,0 16,0 14,8 12,0


14,0 12,4 10,6 7,5

R2CD-R4CD 50

HYDRAULIC PERFORMANCE
WITH ONLY ONE HEAD IN OPERATION

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

MODEL

D1 D2 D3 D4 D5 nD5 D6 D7 nD7 H1 H2 H3 L1 L2

L3 L4

L5 B1 B2 B3 B4 B5

net gross

PACKING
VOLUME
(dm3)

R4CD 50 - 30

50 90 110 165 14

4 125 19

76 225 301 280 117 163 120 96 380 193 187 100 200 M12

31

34

0,081

R4CD 50 - 60

50 90 110 165 14

4 125 19

76 260 336 280 120 160 120 120 440 220 220 120 240 M12

43

46

0,081

R2CD 50 - 60

50 90 110 165 14

4 125 19

76 225 301 280 120 160 120 96 440 220 220 100 200 M12

31

34

0,081

R2CD 50 - 120

50 90 110 165 14

4 125 19

76 260 336 280 120 160 120 120 440 220 220 120 240 M12

45

48

0,081

R2CD 50 - 180

50 90 110 165 14

4 125 19

76 261 337 280 120 160 120 120 440 220 220 120 240 M12

48

51

0,081

88

CIRCULATION PUMPS
R2CD - R4CD CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for the
circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 65 - PN 6/10
- Versions: twin
Motor
- Asynchronous wet rotor with internal separator sleeve, 2 pole
(R2CD) or 4 pole (R4CD)
- Two speed operation
- Class F insulation
- Level of protection IP 42
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view):
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems

HYDRAULIC PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

MODEL

B3620252

VOLTAGE
SPEED
(V)

3 x 230
R4CD 65 - 30

B3620250

3 x 400

B3640552

3 x 230
R4CD 65 - 60

B3640550

3 x 400

B3620502

3 x 230
R2CD 65 - 60

B3620500

3 x 400

B3641102

3 x 230
R2CD 65 - 120

B3641100

3 x 400

B3641702

3 x 230
R2CD 65 - 180

B3641700

3 x 400

2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1

Motor
Power
Amp.
W
max min.
305
185
305
185
540
370
540
370
478
328
478
328
1330
940
1330
940
1970
1510
1970
1510

210
120
210
120
280
175
280
175
302
208
302
208
730
530
730
530
950
720
950
720

1,52
0,70
0,87
0,40
2,55
1,30
1,47
0,55
1,70
1,02
0,98
0,59
4,42
2,85
2,55
1,65
6,65
4,50
3,85
2,60

n
(rpm)
1330
1010
1330
1010
1400
1190
1400
1190
2780
2270
2780
2270
2760
2260
2760
2260
2810
2420
2810
2420

COUNTERFLANGES NOT INCLUDED

89

l/1'

100

200

300

400

600

800

m3/h

12

18

24

36

48

2,9
2,4

2,8
2,1

2,4
1,6

2,1
1,1

1,5
0,5

0,1

5,5
5,1

5,4
4,1

4,8
3,4

4,2
2,4

3,2
1,6

3,2

6,3
5,1

6,0
4,3

5,3
3,2

4,2
2,1

2,8
0,9

11,8 11,4 10,9 10,1


9,5 9,0 7,9 6,9

8,7
5,7

6,1
2,7

18,0 16,9 15,2 12,7 10,6


15,5 13,6 11,0 8,8 6,3

2,5
0,4

PRICE

Discharge Head
in meters

CODE

1,5

R2CD-R4CD 65

HYDRAULIC PERFORMANCE
WITH ONLY ONE HEAD IN OPERATION

B1
L4

B2

L5

B3

H2
H3

M
G 1/4

B4

D7

H1

B4

B5

D5
G1/8
D1
D2
D3

L2

L3
L1

D6
D4

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

MODEL

D1 D2 D3 D4 D5 nD5 D6 D7 nD7 H1 H2 H3

L1 L2 L3 L4

L5 B1 B2 B3

B4 B5 M

net gross

PACKING
VOLUME
(dm3)

R4CD 65 - 30

65 110 130 185 14

145 19

84 226 310 340 136 204 140 96 404 208 196 120 240 M12

40

45

0,096

R4CD 65 - 60

65 110 130 185 14

145 19

84 261 345 340 140 200 140 120 455 231 224 100 200 M12

53

58

0,096

R2CD 65 - 60

65 110 130 185 14

145 19

84 226 310 340 140 200 140 96 455 231 224 120 240 M12

40

45

0,096

R2CD 65 - 120

65 110 130 185 14

145 19

84 261 345 340 140 200 140 120 455 231 224 120 240 M12

54

59

0,096

R2CD 65 - 180

65 110 130 185 14

145 19

84 289 373 340 140 200 140 120 455 231 224 120 240 M12

59

64

0,096

90

CIRCULATION PUMPS
R2CD - R4CD CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for the
circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 80
- PN 10 versions are available on request
- Versions: twin
Motor
- Asynchronous wet rotor with internal separator sleeve, 2 pole
(R2CD) or 4 pole (R4CD)
- Two speed operation
- Class F insulation
- Level of protection IP 42
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems

HYDRAULIC PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

MODEL

VOLTAGE
SPEED
(V)

Motor
n
Power
Amp.
(rpm)
W
max min.

3 x 230

2
1

390
273

B3840250

3 x 400

2
1

390 270
273 185

1,05
0,58

1405
1200

B3840552

3 x 230

2
1

975
710

470
290

4,75
2,50

1400
1200

B3840550

3 x 400

2
1

975 470
710 290

2,75
1,45

1400
1200

B3841102

3 x 230

2
1

1970
1510

950 6,65
720 4,50

2810
2420

B3841100

3 x 400

2
1

1970
1510

730
530

3,85
2,60

2810
2420

B3841702

3 x 230

2
1

2520 2320
1780 1040

7,60
5,40

2800
2450

3 x 400

2
1

2520 2320
1780 1040

4,40
3,10

2800
2450

B3840252
R4CD 80 - 30

R4CD 80 - 60

270 1,82
185 1,00

R2CD 80 - 180

COUNTERFLANGES NOT INCLUDED

91

100

250

500

750 1000 1250


PRICE

m /h

1405
1200

R2CD 80 - 120

B3841700

l/1'
Q

Discharge Head
in meters

CODE

15

30

45

60

3,7
3,1

3,6
2,8

3,2
2,2

1,9
0,7

0,2

6,0
5,4

5,9
5,2

5,7
4,8

4,7
3,2

3,2
0,9

0,8

11,2 11,0 10,8


10,2 9,6 8,8

9,8
6,9

7,8
4,7

5,4
2,2

17,8 17,5 16,7 13,1


15,2 14,6 12,8 7,4

4,6

75

1,3

R2CD-R4CD 80

HYDRAULIC PERFORMANCE
WITH ONLY ONE HEAD IN OPERATION

B1

L4

B2

L5

B3

H2
H3

G1/8

5
D

MODEL

PN
bar D1 D2

H1

B4

B5

B4

G 1/4

L2

D1
D2
D3
D4

OVERALL DIMENSIONS (mm)


D3 D4

D5 nD5 H1

H2 H3

L1

L3
L1

L2

L3

L4

L5

B1

B2 B3

B4 B5

WEIGHT (kg) PACKING


VOLUME
3
M net gross (dm )

R4CD 80 -

30

80 128 150 190 18

98 269 367 360 145 215 143 120 464 236 228 120 240 M12

50

55

0,096

R4CD 80 -

60

80 128 150 190 18

98 289 387 360 145 215 143 120 464 236 228 100 200 M12

60

65

0,096

R2CD 80 - 120

80 128 150 190 18

98 289 387 360 145 215 143 120 464 236 228 120 240 M12

61

66

0,096

R2CD 80 - 180

80 128 150 190 18

98 289 387 360 145 215 143 120 464 236 228 120 240 M12

61

66

0,096

92

CIRCULATION PUMPS
R4CD CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for the
circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 100
- PN 10 versions are available on request
- Versions: twin
Motor
- Asynchronous wet rotor with internal separator sleeve, 4 pole
(R4CD)
- Two speed operation
- Class F insulation
- Level of protection IP 42
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems

HYDRAULIC PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

CODE

MODEL

B3040252

VOLTAGE
SPEED
(V)

3 x 230

2
1

Motor
n
Amp.
Power
(rpm)
W
max min.
669 495
420 340

2,85
1,55

3 x 400

2
1

669 495
420 340

1,65
0,90

1370
1130

B3040552

3 x 230

2
1

1235 880
810 595

5,42
2,95

1375
1120

R4CD 100 - 60
2
1

1235 880
810 595

3,12
1,70

250

500

750 1000 1250 1500

m3/h

15

30

45

60

75

3,7
3,0

3,4
2,6

3,0
2,1

2,3
1,2

1,4
0,1

0,1

6,0
4,6

5,7
4,2

5,2
3,5

4,7
2,7

3,8
1,6

2,6
0,3

PRICE
90

1375
1120

COUNTERFLANGES NOT INCLUDED

93

Discharge Head
in meters

B3040250

3 x 400

1370
1130

R4CD 100 - 30

B3040550

l/1'
Q

1,1

R4CD 100

HYDRAULIC PERFORMANCE
WITH ONLY ONE HEAD IN OPERATION

B1

L4

B2

L5

B3

H2
H3

G1/8

5
D

MODEL

PN
bar D1 D2

H1

B4

B5

B4

G 1/4

L2

D1
D2
D3
D4

OVERALL DIMENSIONS (mm)


D3 D4

D5 nD5 H1

H2 H3

L1

L3
L1

L2

L3

L4

L5

B1

B2 B3

B4 B5

WEIGHT (kg) PACKING


VOLUME
3
M net gross (dm )

R4CD 100 -

30

100 148 170 210 18

108 306 414 450 189 261 187 140 560 286 274 140 240 M16

80

87

0,224

R4CD 100 -

60

100 148 170 210 18

108 327 435 450 189 261 187 140 560 286 274 140 240 M16

82

89

0,224

94

CIRCULATION PUMPS
R2T - R4T CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal
and inline flanged connections, is the alternative type of design
and completes the wet rotor circulation pumps
(R2C - R4C series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush
nut in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 40 - PN 6/10
- Versions: single
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2T) or 4 pole (R4T)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all
positions between horizontal and vertical

D5
D7

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

MODEL

gross

net
D2

H2

H3

B3

B4

B5

R4T 40 - 30

42

80 100 150

14

110 19

67

343 410 250 70

101 75

90

96 M12

20

22

0,039

R2T 40 - 60

42

80 100 150

14

110 19

67

343 410 250 70 101 75

90

96 M12

20

22

0,039

R2T 40 - 120

42

80 100 150

14

110 19

67

343 410 250 70

90

96 M12

20

22

0,039

B1

l/1'
Ia / I n
Q
(%)
m3/h

CODE

MODEL

Motor
Power
(kW)

B2001011

R4T 40 - 30

0,25

1,10

1,90

1380

4,6

B2001015

R2T 40 - 60

0,37

1,00

1,73

2840

4,1

B2001017

R2T 40 - 120

0,55

1,45

2,50

2810

5,2

Amp.
n
3x400 V 3x230 V (rpm)

L1

COUNTERFLANGES NOT INCLUDED

95

Discharge Head
in meters

D3

D4 D5 nD5 D6 D7 nD7 H1

D1

B2

PACKING
VOLUME
(dm3)

101 75

25

50

100

150

200

250

1,5

12

15

3,3

3,2

3,1

2,7

2,4

1,7

6,8

6,7

6,5

5,8

4,8

3,4

1,8

12,0 11,8 11,4 10,5

9,2

7,4

5,3

PRICE

D4

D1
D2

D3

D6

Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops

R2T-R4T 40

96

CIRCULATION PUMPS
R2T - R4T CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal
and inline flanged connections, is the alternative type of design
and completes the wet rotor circulation pumps
(R2C - R4C series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush
nut in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium statar casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 50 - PN 6/10
- Versions: single
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2T) or 4 pole (R4T)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all
positions between horizontal and vertical

D5
D7

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

MODEL
D3

D4 D5 nD5 D6 D7 nD7 H1

D1

D2

R4T 40 - 30

42

80 100 150

14

110 19

67

343 410 250 70

R2T 40 - 60

42

80 100 150

14

110 19

R2T 40 - 120

42

80 100 150

14

110 19

CODE

MODEL

Motor
Power
(kW)

B2001021

R4T 50 - 30

0,25

1,10

B2001023

R4T 50 - 60

0,37

B2001027

R2T 50 - 120

B2001025

R2T 50 - 180

H2

H3

B4

B5

101 75

90

96 M12 20

22

0,039

67

343 410 250 70 101 75

90

96 M12 20

22

0,039

67

343 410 250 70

90

96 M12 20

22

0,039

1,90

1380

4,6

1,25

2,15

1390

4,2

0,75

1,90

3,30

2810

4,5

1,10

2,60

4,50

2860

5,2

COUNTERFLANGES NOT INCLUDED

97

Discharge Head
in meters

l/1'
Ia / I n
Q
(%)
m3/h

B1

B2

101 75

net gross

B3

n
(rpm)

Amp.
3x400 V 3x230 V

L1

PACKING
VOLUME
(dm3)

50

100

200

300

400

500

12

18

24

30

3,1

3,0

2,8

2,5

1,5

5,9

5,7

5,4

4,5

3,3

1,4

12,0 11,9 11,6 10,8

9,1

7,0

3,9

17,5 16,5 15,7 13,3 10,2 6,0

1,2

PRICE

D4

D1
D2

D3

D6

Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops

R2T-R4T 50

98

CIRCULATION PUMPS
R2T - R4T CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal
and inline flanged connections, is the alternative type of design
and completes the wet rotor circulation pumps
(R2C - R4C series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush
nut in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 65 - PN 6/10
- Versions: single
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2T) or 4 pole (R4T)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all positions
between horizontal and vertical

D5
D7

D1

D2

D3 D4 D5 nD5 D6 D7 nD7 H1 H2

H3

L1

B1

B2

B3

B4

B5

gross

75 124

96 M12

26

29

0,073

75 124

96 M12

29

32

0,073

82 382 464 340

80 115 101 124

96 M12

33

36

0,073

82 401 483 340

90 115 101 124

96 M12

36

39

0,073

R4T 65 - 30

65

110 130 185

14

145 19

82 347 429 340

R4T 65 - 60

65

110 130 185

14

145 19

82 347 429 340 80

R2T 65 - 120

65

110 130 185

14

145 19

R2T 65 - 180

65

110 130 185

14

145 19

CODE

MODEL

Motor
Power
(kW)

B2001031

R4T 65 - 30

0,25

1,10

1,90

1380

4,6

B2001033

R4T 65 - 60

0,37

1,25

2,15

1390

4,2

B2001037

R2T 65 - 120

1,10

2,50

4,30

2840

5,8

B2001035

R2T 65 - 180

1,50

3,40

5,90

2870

6,0

l/1'
Ia / I n
Q
(%)
m3/h

COUNTERFLANGES NOT INCLUDED

99

Discharge Head
in meters

Amp.
n
3x400 V 3x230 V (rpm)

net

PACKING
VOLUME
(dm3)

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

MODEL

0
0

70 101
101

100
6

200
12

300
18

400
24

500
30

3,0

2,9

2,7

2,3

1,8

1,2

5,5

5,4

4,9

4,4

3,6

2,7

11,3 11,0 10,4

9,9

9,0

7,8

17,4 16,8 15,7 13,8 10,8

6,7

700
42

4,2

PRICE

D4

D1
D2

D3

D6

Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops

R2T-R4T 65

100

CIRCULATION PUMPS
R2T - R4T CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal
and inline flanged connections, is the alternative type of design
and completes the wet rotor circulation pumps
(R2C - R4C series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush
nut in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 80
- PN 10 versions are available on request
- Versions: single
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2T) or 4 pole (R4T)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all
positions between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops

MODEL

OVERALL DIMENSIONS (mm)

WEIGHT (kg) PACKING


VOLUME
M net gross (dm3)

PN
bar

D1

D2

D4

D3

D5 nD5

H1

H2

H3

L1

B1

B2

B3

B4

B5

97

348

445

360

70

101

101

130

96

M12

32

35

0,073

R4T 80 -

30

80

128

150

190

18

R4T 80 -

60

80

128

150

190

18

97

383

480

360

80

115

101

130

96

M12

36

39

0,073

R2T 80 - 120

80

128

150

190

18

97

433

530

360

90

115

101

130

96

M12

41

44

0,073

R2T 80 - 180

80

128

150

190

18

97

433

530

360

90

115

101

130

96

M12

41

44

0,073

CODE

MODEL

Motor
Power
(kW)

B2001041

R4T 80 - 30

0,25

1,10

B2001043

R4T 80 - 60

0,75

B2001047

R2T 80 - 120

B2001045

R2T 80 - 180

l/1'
Ia / I n
Q
(%)
m3/h

0
0

1,90

1380

4,6

2,25

3,90

1405

5,1

2,20

4,80

8,30

2870

4,8

2,20

4,80

8,30

2870

4,8

COUNTERFLANGES NOT INCLUDED

101

Discharge Head
in meters

n
(rpm)

Amp.
3x400 V 3x230 V

200
12

300
18

400
24

500
30

750 1000
45
60

3,7

3,3

3,0

2,5

2,0

6,0

5,8

5,6

5,3

4,9

3,3

11,7 11,4 11,2 10,6 10,3

8,4

17,6 17,0 16,4 15,0 13,4

6,4

5,5

PRICE

R2T-R4T 80

102

CIRCULATION PUMPS
R2T - R4T CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal
and inline flanged connections, is the alternative type of design
and completes the wet rotor circulation pumps
(R2C - R4C series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush
nut in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 100
- PN 10 versions are available on request
- Versions: single
Motor
- Squirrel cage asynchronous three phase with enclosed
stator, externally ventilated, 2 pole (R2T) or 4 pole (R4T)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all
positions between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops

MODEL

OVERALL DIMENSIONS (mm)

PN
bar

D1

D2

D4

D3

D5 nD5

H1

H2

H3

L1

B1

B2

B3

B4

B5

WEIGHT (kg) PACKING


VOLUME
(dm3)
net gross

R4T 100 -

30

100

148

170

210

18

107

421

528

450

80

115

101

167

144 M16

49

56

0,249

R4T 100 -

60

100

148

170

210

18

107

457

564

450

90

115

101

167

144 M16

57

64

0,249

R2T 100 - 120

100

148

170

210

18

107

507

614

450

100

130

101

167

144 M16

62

69

0,249

CODE

MODEL

Motor
Power
(kW)

B2001051

R4T 100 - 30

0,55

1,70

2,90

1390

4,5

B2001053

R4T 100 - 60

1,10

3,00

5,20

1395

4,0

B2001057

R2T 100 - 120

3,00

6,30

10,90

2870

4,2

l/1'
Ia / I n
Q
(%)
m3/h

COUNTERFLANGES NOT INCLUDED

103

Discharge Head
in meters

Amp.
n
3x400 V 3x230 V (rpm)

0
0

250
15

500
30

750 1000 1250 1400


45
60
75
84

4,0

3,7

3,2

2,4

1,3

6,0

5,9

5,7

5,3

4,6

3,4

13,0 12,7 12,4 11,2

9,4

7,4

4,5

PRICE

R2T-R4T 100

104

CIRCULATION PUMPS
R2TD - R4TD CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the circulation
of hot and cold water in heating and air-conditioning systems. The
type of design: external motor, mechanical seal and inline flanged
connections, is the alternative type of design and completes the
wet rotor circulation pumps (R2CD - R4CD series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush nut
in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 40 - PN 6/10
- Versions: twin
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2TD) or 4 pole (R4TD)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of suspended
solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all positions
between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops

D7
D5

D1
D2
D3
D6
D4

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

MODEL

net gross
D1 D2 D3 D4 D5 nD5 D6 D7 nD7 H1 H2 H3 L1

L2 L3 L4

L5 B1

B2 B3 B4 B5

PACKING
VOLUME
(dm3)

R4TD 40 - 30

42 80 100 150 14

110 19

68 343 411 250 99 151 97

96 184 101 180 100 200 M12

27

30

0,068

R2TD 40 - 60

42 80 100 150 14

110 19

68 343 411 250 99 151 97

96 184 101 180 100 200 M12

27

30

0,068

R2TD 40 - 120

42 80 100 150 14

110 19

68 343 411 250 99 151 97 96 184 101 180 100 200 M12

29

32

0,073

HYDRAULIC PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

CODE

MODEL

Motor
Power
(kW)

B2001010

R4TD 40 - 30

2 x 0,25

1,10

1,90

1380

4,6

B2001016

R2TD 40 - 60

2 x 0,37

1,00

1,73

2840

4,1

B2001018

R2TD 40 - 120

2 x 0,55

1,45

2,50

2810

5,2

l/1'
Ia / I n
Q
(%)
m3/h

COUNTERFLANGES NOT INCLUDED

105

Discharge Head
in meters

Amp.
n
3x400 V 3x230 V (rpm)

0
0

25
1,5

50
3

100
6

150
9

3,3

3,1

6,8

6,2

200 250
15
12

2,8

2,4

1,8

5,8

4,8

3,6

2,0

12,0 11,5 11,2 10,0

8,5

6,2

PRICE

R2TD-R4TD 40

106

CIRCULATION PUMPS
R2TD - R4TD CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal and
inline flanged connections, is the alternative type of design and
completes the wet rotor circulation pumps (R2CD - R4CD series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush nut
in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 50 - PN 6/10
- Versions: twin
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2TD) or 4 pole (R4TD)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all positions
between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops

D7
D5

D1
D2
D3
D6
D4

D1 D2 D3

D4 D5 nD5 D6 D7 nD7 H1 H2 H3

L1

L2

L3 L4

net

gross

PACKING
VOLUME
(dm3)

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

MODEL

L5 B1 B2 B3 B4 B5

R4TD 50 - 30

50

90 110 165 14

4 125 19

76 337 413 280 117 163 120 96 380 193 187 100 200 M12

31

34

0,073

R4TD 50 - 60

50

90 110 165 14

4 125 19

76 337 413 280 120 160 120 120 440 220 220 120 240 M12

43

46

0,073

R2TD 50 - 120

50

90 110 165 14

4 125 19

76 337 413 280 120 160 120 120 440 220 220 120 240 M12

31

34

0,073

R2TD 50 - 180

50

90 110 165 14

4 125 19

76 337 413 280 120 160 120 120 440 220 220 120 240 M12

35

38

0,073

HYDRAULIC PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

CODE

MODEL

Motor
Power
(kW)

B2001020

R4TD 50 - 30

2 x 0,25

1,10

1,90

1380

4,6

B2001022

R4TD 50 - 60

2 x 0,37

1,25

2,15

1390

4,2

B2001028

R2TD 50 - 120

2 x 0,75

1,90

3,30

2810

4,5

B2001026

R2TD 50 - 180

2 x 1,10

2,60

4,50

2860

5,2

n
(rpm)

l/1'
Ia / I n
Q
(%)
m3/h

COUNTERFLANGES NOT INCLUDED

107

Discharge Head
in meters

Amp.
3x400 V 3x230 V

0
0

50
3

100
6

200
12

300
18

400
24

3,1

2,8

2,7

1,9

0,8

5,9

5,7

5,4

4,2

3,6

1,4

12,0 11,8 11,3

9,9

7,8

5,2

17,5 16,1 15,3 13,2 10,0

5,8

500
30

PRICE

R2TD-R4TD 50

108

CIRCULATION PUMPS
R2TD - R4TD CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal and
inline flanged connections, is the alternative type of design and
completes the wet rotor circulation pumps (R2CD - R4CD series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush nut
in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator Casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 65 - PN 6/10
- Versions: twin
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2TD) or 4 pole (R4TD)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all positions
between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops

D7
D5

D1
D2
D3
D6
D4

D1 D2 D3 D4 D5 nD5 D6 D7 nD7 H1 H2 H3 L1

L2 L3

L4

net

gross

PACKING
VOLUME
(dm3)

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

MODEL

L5 B1 B2 B3 B4 B5

R4TD 65 - 30

65 110 130 185 14

4 145 19

84 347 431 340 136 204 120 96 404 208 196 120 240 M12

45

50

0,073

R4TD 65 - 60

65 110 130 185 14

4 145 19

84 347 431 340 140 200 140 120 455 231 224 100 200 M12

40

45

0,073

R2TD 65 - 120

65 110 130 185 14

4 145 19

84 382 466 340 140 200 140 120 455 231 224 120 240 M12

40

45

0,073

R2TD 65 - 180

65 110 130 185 14

4 145 19

84 401 485 340 140 200 140 120 455 231 224 120 240 M12

46

51

0,073

HYDRAULIC PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

CODE

MODEL

Motor
Power
(kW)

B2001030

R4TD 65 - 30

2 x 0,25

1,10

1,90

1380

4,6

B2001032

R4TD 65 - 60

2 x 0,37

1,25

2,15

1390

4,2

B2001038

R2TD 65 - 120

2 x 1,10

2,50

4,30

2840

5,8

B2001036

R2TD 65 - 180

2 x 1,50

3,40

5,90

2870

6,0

l/1'
Ia / I n
Q
(%)
m3/h

0
0

COUNTERFLANGES NOT INCLUDED

109

Discharge Head
in meters

Amp.
n
3x400 V 3x230 V (rpm)

100
6

200
12

300
18

400
24

500
30

3,0

2,8

2,4

1,9

1,3

5,3

5,2

4,7

4,0

2,8

1,6

11,0 10,9 10,4

9,3

8,2

7,0

17,4 16,8 15,7 13,8 10,8

7,2

700
42

PRICE

R2TD-R4TD 65

110

CIRCULATION PUMPS
R2TD - R4TD CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal and
inline flanged connections, is the alternative type of design and
completes the wet rotor circulation pumps (R2CD - R4CD series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush nut
in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 80
- PN 10 versions are available on request
- Versions: twin
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2TD) or 4 pole (R4TD)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all positions
between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops

PN
bar D1 D2

MODEL

WEIGHT (kg) PACKING


VOLUME
(dm3)
net gross

OVERALL DIMENSIONS (mm)


D3 D4

D5 nD5 H1

H2 H3

L1

L2

L3

L4

L5

B1 B2

B3 B4 B5

R4TD 80 -

30

80 128 150 190 18

98 348 446 360 145 215 140 120 464 236 228 120 240 M12

54

59

0,073

R4TD 80 -

60

80

128 150 190 18

98 375 481 360 145 215 143 120 464 236 228 120 240 M12 50

55

0,073

R2TD 80 - 120

80

128 150 190 18

98 433 531 360 145 215 143 120 464 236 228 120 240 M12

60

65

0,224

R2TD 80 - 180

80

128 150 190 18

98 433 531 360 145 215 143 120 464 236 228 120 240 M12

66

65

0,224

HYDRAULIC PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

CODE

MODEL

Motor
Power
(kW)

B2001040

R4TD 80 - 30

2 x 0,25

1,10

1,90

1380

4,6

B2001042

R4TD 80 - 60

2 x 0,75

2,25

3,90

1405

5,1

B2001048

R2TD 80 - 120

2 x 2,20

4,80

8,30

2870

4,8

B2001046

R2TD 80 - 180

2 x 2,20

4,80

8,30

2870

4,8

l/1'
Ia / I n
Q
(%)
m3/h

COUNTERFLANGES NOT INCLUDED

111

Discharge Head
in meters

Amp.
n
3x400 V 3x230 V (rpm)

0
0

200
12

300
18

400
24

500
30

750 1000
45
60

3,7

3,2

2,7

2,2

1,5

6,0

5,7

5,2

4,7

4,3

2,5

11,7 11,0 10,4

9,8

9,2

6,8

17,6 17,0 16,4 15,5 14,3

6,4

3,5

PRICE

R2TD-R4TD 80

112

CIRCULATION PUMPS
R2TD - R4TD CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal and
inline flanged connections, is the alternative type of design and
completes the wet rotor circulation pumps (R2CD - R4CD series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush nut
in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 100
- PN 10 versions are available on request
- Versions: twin
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2TD) or 4 pole (R4TD)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all positions
between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops

PN
bar D1

MODEL

OVERALL DIMENSIONS (mm)


D2 D3 D4

D5 nD5 H1

H2 H3

L1

L2

L3

L4

L5

B1 B2

B3 B4

B5

WEIGHT (kg) PACKING


VOLUME
M net gross (dm3)

R4TD 100 -

30

100 148 170 210 18

108 421 529 450 189 261 143 140 560 286 274 140 280 M16

61

68

0,224

R4TD 100 -

60

100 148 170 210 18

108 457 565 450 189 261 187 140 560 286 274 140 280 M16

80

87

0,224

R2TD 100 - 120

100 148 170 210 18

108 504 615 450 189 261 187 140 560 286 274 140 280 M16

82

89

0,224

HYDRAULIC PERFORMANCE WITH ONLY ONE HEAD IN OPERATION

CODE

MODEL

Motor
Power
(kW)

B2001050

R4TD 100 - 30

2 x 0,55

1,70

2,90

1390

4,5

B2001052 R4TD 100 - 60

2 x 1,10

3,00

5,20

1395

4,0

B2001058

2 x 3,00

6,30

10,90

2870

4,2

l/1'
Ia / I n
Q
(%)
m3/h

COUNTERFLANGES NOT INCLUDED

113

Discharge Head
in meters

R2TD 100 - 120

Amp.
n
3x400 V 3x230 V (rpm)

0
0

250
15

500
30

750 1000 1250 1400


45
60
90 120

3,8

3,3

2,8

2,1

6,0

5,6

5,1

4,3

3,4

13,8 13,2 12,1 10,6

8,6

PRICE

R2TD-R4TD 100

114

CIRCULATION PUMPS
A2L - A4L - CIRCULATION PUMPS
Applications
- Heating and air-conditioning systems
- Water lifting from lakes , rivers, wells, etc.
- Irrigation systems on ground surface or by sprinkling.
- Water supply and distribution for isolated houses or small villages.
- Pressure systems.
- Industrial services.
- Domestic hot water supply systems.
Construction features
It is a single impeller centrifugal pump coupled by a spindle to a totally
enclosed asynchronous motor. The motor cooling is obtained by means
of external ventilation. The shaft seal is of the mechanical type.
Single construction. Performance data as given on the guidelist and
on the nameplate refer to continuous duty and clear water ( specific
Weight: 1000 Kg / m3 ) with a manometric suction head of 2 meters.
Installation
Since suction and delivery are in-line, pump can be installed in line
with the piping, either horizontally or vertically. Do not install the pump
with motor facing downwards.
On request the pumps can be supplied with flanged counterflanges.
Construction materials
- Pump casing : Cast iron
- Impeller : Cast iron
- Shield, lantern, cover: cast iron
- Shaft: Stainless steel
Pump working limits
- Max working pressure: 10 bar .
- Max liquid temperature: +130 C .
- Min. liquid temperature : -10 C
- Max ambient temperature : +40 C
- Max liquid viscosity : 5 E.
Motor
Asynchronous Threephase motor.
- Protection: IP 54
- Standard voltages:
50 Hz: V. 220 - 400 ( +-10 % )
- Insulation: Class F
Tolerances
- Pump: ISO 2548 class C annex B.
- Motor: according to CEI standards.

A2L

A4L

H
[m]

H
[m]

100-250

50

20

40-200
65-200

40

80-200
100-200

50-200

100-250

15

30

80-200

40-160
50-160

25
20

65-160

80-160

40-125

15

50-125

40-200

10
100-160

65-200
100-200

8
40-160

65-125

80-160
50-200
100-160

65-160

5
50-160

10

8
6

5
2

4
1,2

12

24

60

120

0,6

180

Q [m3/h]

1,2

12

24

60

120

180

Q [m3/h]

115

A2L - A4L 40
CODE

Motor
Power

MODEL

L/1' 50
n -1
Q
(min
)
3x400V 3x230V
m3/h 3
Amp.

(Kw)

75

100 125 150 175 200 225 250 300 350 400
PRICE

4,5

7,5

10,5

12

13,5

9,2

8,9

8,3

7,7

N8020380 A4L 40 - 160 X

0,37

1,15

4 poli

9,4

6,9

5,8

4,7

N8020390 A4L 40 - 200 Y

13 12,8 12,4 11,9 11,3 10,6

9,8

15

18

3,5

4 poli

0,9

2,4

4,2

4 poli

14,5 14,3 13,8 13,3 12,7 11,8 10,9 10

N8020000 A2L 40 - 125 C

0,75

1,9

3,3

2 poli

16,5 15,5 14,5 13,5 12,3 11

9,5

N8020010 A2L 40 - 125 B

1,0

2,4

4,2

2 poli

N8020020 A2L 40 - 125 A

1,5

3,6

6,2

2 poli

N8020030 A2L 40 - 160 C

2,0

4,4

7,7

2 poli

N8020040 A2L 40 - 160 B

3,0

6,4

11

2 poli

N8020050 A2L 40 - 160 A

3,0

6,4

11

2 poli

N8020060 A2L 40 - 200 C

4,0

8,8

15,2

N8020070 A2L 40 - 200 B

5,5

11,3

N8020080 A2L 40 - 200 A

6,3

12,8

Discharge Head
in meters

0,75

N8020400 A4L 40 - 200 X

21

24

20,5

20

19

18

17

16

15

11,5

7,5

24,5

24

23,5

23

22

21

20

16,5

13

28,5

28

27,5 26,5 25,5 24

23

20

15

33,5

33

32,5

32

31

30

29

26

22,5

38

37,5

37

36

35

34

33

30

26,5

2 poli

47

46,5

46

45

44

43

42

2 poli

55

54,5

54

53,5

53

52

51

48

45

42

2 poli

62

61,5

61

60

59

58

57

54

52,5

49

39,5 37,5

35

COUNTERFLANGES NOT INCLUDED

E
B

F
D

MODEL

MOTOR

DN : Flanges

DN

n d holes e

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

FLANGES mm.

DNa
DNm
a

A4L 40 - 160 X

71

40 PN10

88

110

150

18

425

100

325

215

103

107

320

170

150

23

A4L 40 - 200 X

80

40 PN10

88

110

150

18

445

100

345

245

127

118

380

200

180

31

A4L 40 - 200 Y

80

40 PN10

88

110

150

18

445

100

345

245

127

118

380

200

180

30

A2L 40 - 125 A

80

40 PN10

88

110

150

18

445

100

345

211

93

118

300

160

140

26

A2L 40 - 125 B

80

40 PN10

88

110

150

18

445

100

345

211

93

118

300

160

140

25

A2L 40 - 125 C

71

40 PN10

88

110

150

18

425

100

325

200

93

107

300

160

140

24

A2L 40 - 160 A

90

40 PN10

88

110

150

18

485

100

385

257

108

149

320

170

150

37

A2L 40 - 160 B

90

40 PN10

88

110

150

18

485

100

385

257

108

149

320

170

150

35

A2L 40 - 160 C

80

40 PN10

88

110

150

18

445

100

345

226

108

118

320

170

150

30

A2L 40 - 200 A

112

40 PN10

88

110

150

18

535

100

435

286

127

159

380

200

180

56

A2L 40 - 200 B

112

40 PN10

88

110

150

18

535

100

435

286

127

159

380

200

180

55

A2L 40 - 200 C

110

40 PN10

88

110

150

18

525

100

425

286

127

159

380

200

180

50

116

A2L - A4L 50

CIRCULATION PUMPS
CODE

MODEL

Motor
Power

(Kw)

L/1' 100 125 150 175 200 225 250 300 350 400 450 500 600
n -1
Q
(min
)
3x400V 3x230V
m3/h 6 7,5 9 10,5 12 13,5 15 18 21 24 27 30 36
Amp.

N8020410 A4L 50 - 160 X

0,5

1,6

2,8

4 poli

8,8 8,6

N8020420 A4L 50 - 200 Y

1,1

2,6

4,5

4 poli

12,7 12,5 12,1 11,7 11,2 10,7 10,1 8,5

N8020430 A4L 50 - 200 X

1,1

2,6

4,5

4 poli

14,2 14 13,8 13,4 13 12,5 12

N8020090 A2L 50 - 125 C

1,5

3,6

6,2

2 poli

N8020100 A2L 50 - 125 B

2,0

4,4

7,7

2 poli

N8020110 A2L 50 - 125 A

3,0

8,8

15,2

2 poli

N8020120 A2L 50 - 160 B

3,0

6,4

11

2 poli

N8020130 A2L 50 - 160 A

4,0

8,8

15,2

2 poli

N8020140 A2L 50 - 200 C

5,5

11,3

2 poli

N8020150 A2L 50 - 200 B

6,3

12,8

2 poli

N8020160 A2L 50 - 200 A

7,5

17,3

2 poli

8,3 8,0

7,7

7,3 6,9 5,9

4,5
7
8,3

10

15,5 15 14,1 13 11,8 10,5

Discharge Head
in meters

PRICE

19 18,5 17,5 16,5 15,5 14,5 10,5


24,5 24 23,5 23

22 20,5 17
23

18

36,5 35,5 34,5 33,5 32,5 31

27

30

28 26,5 25

29

46

44

43 41,5 39

51

50

49 47,5 45 42,5 37

56,5 55,5 54,5 53

51

37

31

49

44

COUNTERFLANGES NOT INCLUDED

E
B

F
D

MODEL

MOTOR

DN : Flanges

DN

n d holes e

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

FLANGES mm.

DNa
DNm
a

A4L 50 - 160 X

71

50 PN10

102

125

165

18

435

110

325

220

113

107

340

180

160

25

A4L 50 - 200 X

90

50 PN10

102

125

165

18

495

110

385

280

131

149

400

220

180

36

A4L 50 - 200 Y

90

50 PN10

102

125

165

18

495

110

385

280

131

149

400

220

180

36

A2L 50 - 125 A

90

50 PN10

102

125

165

18

495

110

385

252

103

149

320

180

140

32

A2L 50 - 125 B

80

50 PN10

102

125

165

18

455

110

345

221

103

118

320

180

140

28

A2L 50 - 125 C

80

50 PN10

102

125

165

18

455

110

345

221

103

118

320

180

140

27

A2L 50 - 160 A

100

50 PN10

102

125

165

18

535

110

425

272

113

159

340

180

160

42

A2L 50 - 160 B

90

50 PN10

102

125

165

18

495

110

385

262

113

149

340

180

160

32

A2L 50 - 200 A

132

50 PN10

102

125

165

18

650

110

540

315

131

184

400

220

180

64

A2L 50 - 200 B

112

50 PN10

102

125

165

18

545

110

435

290

131

159

400

220

180

57

A2L 50 - 200 C

112

50 PN10

102

125

165

18

545

110

435

290

131

159

400

220

180

56

117

A2L - A4L 65

CIRCULATION PUMPS
CODE

MODEL

L/1' 200 225 250 300 350 400 450 500 600 700 800 900 1000
Amp.
n
Q
-1
3x400V 3x230V (min )
m3/h 12 13,5 15 18 21 24 27 30 36 42 48 54 60

Motor
Power

(Kw)

N8020440 A4L 65 - 160 Y

0,75

3,5

4 poli

8,2

N8020450 A4L 65 - 160 X

0,9

2,4

4,2

4 poli

9,0

N8020460 A4L 65 - 200 Y

1,1

2,6

4,5

N8020070 A4L 65 - 200 X

1,5

3,5

6,1

N8020180 A2L 65 - 125 C

2,0

4,4

7,7

2 poli

N8020170 A2L 65 - 125 B

3,0

6,4

11

2 poli

N8020190 A2L 65 - 125 A

4,0

8,8

15,2

2 poli

N8020200 A2L 65 - 160 B

5,5

11,3

2 poli

N8020210 A2L 65 - 160 A

7,5

17,3

2 poli

37 36,5 36

35

N8020220 A2L 65 - 200 B

10

22,5

2 poli

51 50,5 50

48 45,5 42 39,5 37

N8020230 A2L 65 - 200 A

12,5

27

2 poli

58 57,5 57

55

7,4

7,0

6,6 6,0 4,0

8,4

8,1

7,7 7,2 5,5

4 poli

12,4 12,2 12 11,5 10,8 10

9,0 8,0 5,8

4 poli

14,3 14,2 14,1 13,7 13 12,3 11,3 10,2 7,8

5,0

15

13

Discharge Head
in meters

7,9 7,7

8,9 8,8 8,6

17 16,5 16
21 20,5 20

11

19 17,5 16

14

12

23 21,5 20

18

24

25,5 25,3 25

32,5 32 31,5 30,5 29,5 28

26 23,5

34 32,5 31

53

PRICE

29

50 46,5 42,5

COUNTERFLANGES NOT INCLUDED

E
B

MODEL

MOTOR

DN : Flanges

DN

n d holes e

FLANGES mm.

DNa
DNm

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

A4L 65 - 160 X

80

65 PN10

122

145

185

18

485

140

345

240

122

118

400

220

180

33

A4L 65 - 160 Y

80

65 PN10

122

145

185

18

485

140

345

240

122

118

400

220

180

32

A4L 65 - 200 X

90

65 PN10

122

145

185

18

525

140

385

285

136

149

440

240

200

40

A4L 65 - 200 Y

90

65 PN10

122

145

185

18

525

140

385

285

136

149

440

240

200

38

A2L 65 - 125 A

100

65 PN10

122

145

185

18

565

140

425

267

108

159

360

205

155

43

A2L 65 - 125 B

90

65 PN10

122

145

185

18

525

140

385

257

108

149

360

205

155

39

A2L 65 - 125 C

80

65 PN10

122

145

185

18

485

140

345

226

108

118

360

205

155

32

A2L 65 - 160 A

132

65 PN10

122

145

185

18

680

140

540

306

122

184

400

220

180

61

A2L 65 - 160 B

112

65 PN10

122

145

185

18

575

140

435

281

122

159

400

220

180

54

A2L 65 - 200 A

132

65 PN10

122

145

185

18

680

140

540

320

136

184

440

240

200

77

A2L 65 - 200 B

132

65 PN10

122

145

185

18

680

140

540

320

136

184

440

240

200

70

118

A2L - A4L 80

CIRCULATION PUMPS
CODE

MODEL

Motor
Power

(Kw)

L/1' 300 350 400 450 500 600 700 800 900 1000 1100 1200 1250 1500 1750 2000 2250
Amp.
n
-1 Q
3x400V 3x230V (min )
m3/h 18 21 24 27 30 36 42 48 54 60 66 72 75 90 105 120 135

N8020480 A4L 80 - 160 Y

1,1

2,6

4,5

2 poli

8,6 8,5 8,4 8,3 8,2 8,0 7,5 6,8 6,0 5,0

N8020490 A4L 80 - 160 X

1,5

3,5

6,1

2 poli

10,2 10,1 10 9,9 9,8 9,4 9,0 8,5 7,7 6,5

N8020500 A4L 80 - 200 Y

2,2

5,1

8,9

2 poli

N8020510 A4L 80 - 200 X

3,0

6,9

12

2 poli

N8020240 A2L 80 - 160 C

10

22,5

2 poli

N8020250 A2L 80 - 160 B

12,5

27

2 poli

N8020260 A2L 80 - 160 A

15

32

2 poli

N8020270 A2L 80 - 200 D

15

32

2 poli

44 43,5 43 42,6 42 41,5 39 35,5 31,5

N8020280 A2L 80 - 200 C

18,5

38

2 poli

51 50 49,5 49 48,5 48,3 46,5 43,5 39,5 35

N8020290 A2L 80 - 200 B

22

44,5

2 poli

57 56,5 56 55,6 55,4 55 53,5 51 48 42,5

PRICE

Discharge Head
in meters

12,5 12,4 12,3 12,1 11,7 11,1 10,5 9,6 8,5


15,2 15 14,6 14,3 13,6 12,8 12

11

30,5 30 29,5 29 28,2 27,3 26,5 24 20,5 16


36,5 36 35,5 34,5 34 33,2 33

27 23

19

41 40,5 40 39,5 38,7 38 37,5 35,5 33 29

30

24

COUNTERFLANGES NOT INCLUDED

E
B

F
D

MODEL

MOTOR

DN : Flanges

DN

n d holes e

FLANGES mm.

DNa
DNm

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

A4L 80 - 160 X

90

80 PN10

138

160

200

18

545

140

325

280

131

149

440

240

200

40

A4L 80 - 160 Y

90

80 PN10

138

160

200

18

545

140

325

280

131

149

440

240

200

38

A4L 80 - 200 X

100

80 PN10

138

160

200

18

585

140

345

305

146

159

500

275

225

57

A4L 80 - 200 Y

100

80 PN10

138

160

200

18

585

140

345

305

146

159

500

275

225

51

A2L 80 - 160 A

132

80 PN10

138

160

200

18

700

160

540

315

131

184

440

240

200

85

A2L 80 - 160 B

132

80 PN10

138

160

200

18

700

160

540

315

131

184

440

240

200

79

A2L 80 - 160 C

132

80 PN10

138

160

200

18

700

160

540

315

131

184

440

240

200

72

A2L 80 - 200 B

180

80 PN10

138

160

200

18

860

160

700

375

146

229

500

275

225

142

A2L 80 - 200 C

160

80 PN10

138

160

200

18

860

160

700

375

146

229

500

275

225

124

A2L 80 - 200 D

132

80 PN10

138

160

200

18

700

160

540

330

146

184

500

275

225

91

119

A2L - A4L 100

CIRCULATION PUMPS
CODE

Motor
Power

MODEL

(Kw)

Amp.
n
-1 Q
3x400V 3x230V (min )

L/1' 600 700 800 900 1000 1100 1200 1250 1300 1500 1750 2000 2250 2500 2750 3000 3500
PRICE
36

m3/h

42

48

54

60

66

72

75

78

90 105 120 135 150 165 180 210

N8020520 A4L 100 - 160 Y

1,5

3,5

6,1

4 poli

N8020530 A4L 100 - 160 X

2,2

5,1

8,9

4 poli

9,7 9,5 9,3 9,0 8,8 8,5 8,2

N8020540 A4L 100 - 200 Y

3,0

6,9

12

4 poli

12 11,7 11,5 11,3 11 10,5 10

N8020550 A4L 100 - 200 X

4,0

9,2

16

4 poli

14,5 14,2 14 13,8 13,5 13,1 12,7 12,4 12,2 11 9,0 6,5

N8020560 A4L 100 - 250 Y

5,5

12

4 poli

19 18,5 18 17,5 17,4 17

N8020570 A4L 100 - 250 X

7,5

16

4 poli

N8020300 A2L 100 - 160 D

10

22,5

2 poli

N8020310 A2L 100 - 160 C

12,5

27

2 poli

N8020320 A2L 100 - 160 B

15

32

2 poli

34 33,7 33,5 33,3 33,2 32,5 31,8 31

29 27,5 26 24,5

N8020330 A2L 100 - 200 D

18,5

38

2 poli

42 41,5 41,2 41 40,8 40 38,5 37

35

33 30,5 38

N8020340 A2L 100 - 200 C

22

44,5

2 poli

47 46,7 46,5 46,5 46,2 45,5 44,5 43

41

39

37

34

N8020350 A2L 100 - 200 B

30

58

2 poli

N8020360 A2L 100 - 200 A

37

71

2 poli

55 54,5 54,3 54 54 53 52
57 56,9 56,8 56,8 56,6 56,5 56

51
55

49 47 45
54 52,5 51

43
48

37
42

N8020370 A2L 100 - 250 D

37

71

2 poli

65

63

58

55

47

Discharge Head
in meters

7,7 7,5 7,3 7,0 6,7 6,4 6,1 5,7 5,8 5,0
8

7,9 7,1 6,0

9,8 9,5 8,5 7,0

16

14

12

22 21,9 21,7 21,5 21,1 21,9 20

19

17

24 23,6 23,2 23 22,8 22


28,5 28,3 28 27,8 27,7 27

68 67,5 67

21 19,5 18 16,5 15
26 24,5 23 21,5 20 18,5

66

61

COUNTERFLANGES NOT INCLUDED

E
B

F
D

MODEL

MOTOR

DN : Flanges

DN

n d holes e

FLANGES mm.

DNa
DNm

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

A4L 100 - 160 X

100

100 PN10

158

180

220

18

615

190

425

295

136

159

525

300

225

50

A4L 100 - 160 Y

90

100 PN10

158

180

220

18

575

190

385

285

136

149

525

300

225

45

A4L 100 - 200 X

112

100 PN10

158

180

220

18

625

190

435

315

156

159

550

300

250

73

A4L 100 - 200 Y

100

100 PN10

158

180

220

18

615

190

425

315

156

159

550

300

250

66

A4L 100 - 250 X

132

100 PN10

158

180

220

18

730

190

540

360

176

184

600

320

280

106

A4L 100 - 250 Y

132

100 PN10

158

180

220

18

730

190

540

360

176

184

600

320

280

96

A2L 100 - 160 B

132

100 PN10

158

180

220

18

730

190

540

320

136

184

525

300

225

91

A2L 100 - 160 C

132

100 PN10

158

180

220

18

730

190

540

320

136

184

525

300

225

84

A2L 100 - 160 D

132

100 PN10

158

180

220

18

730

190

540

320

136

184

525

300

225

76

A2L 100 - 200 A

200

100 PN10

158

180

220

18

995

190

805

413

156

257

550

300

250

213

A2L 100 - 200 B

200

100 PN10

158

180

220

18

995

190

805

413

156

257

550

300

250

195

A2L 100 - 200 C

180

100 PN10

158

180

220

18

890

190

710

386

156

230

550

300

250

153

A2L 100 - 200 D

160

100 PN10

158

180

220

18

890

190

710

386

156

230

550

300

250

135

A2L 100 - 250 D

200

100 PN10

158

180

220

18

995

190

805

433

176

257

600

320

280

220

120

A2LD - A4LD

CIRCULATION PUMPS
A2L - A4L - CIRCULATION PUMPS
Applications
- Heating and air-conditioning systems
- Water lifting from lakes , rivers, wells, etc.
- Irrigation systems on ground surface or by sprinkling.
- Water supply and distribution for isolated houses or small villages.
- Pressure systems.
- Industrial services.
- Domestic hot water supply systems.
Construction features
It is a single impeller centrifugal pump coupled by a spindle to a totally
enclosed asynchronous motor. The motor cooling is obtained by means
of external ventilation. The shaft seal is of the mechanical type.
Twin construction. Performance data as given on the guidelist and on
the nameplate refer to continuous duty and clear water ( specific
Weight: 1000 Kg / m3 ) with a manometric suction head of 2 meters.
Installation
Since suction and delivery are in-line, pump can be installed in line
with the piping, either horizontally or vertically. Do not install the pump
with motor facing downwards.
On request the pumps can be supplied with flanged counterflanges.
Construction materials
- Pump casing : Cast iron
- Impeller : Cast iron
- Shield, lantern, cover: cast iron
- Shaft: Stainless steel
Pump working limits
- Max working pressure: 10 bar .
- Max liquid temperature: +130 C .
- Min. liquid temperature : -10 C
- Max ambient temperature : +40 C
- Max liquid viscosity : 5 E.
Motor
Asynchronous Threephase motor.
- Protection: IP 54
- Standard voltages:
50 Hz: V. 220 - 400 ( +-10 % )
- Insulation: Class F
Tolerances
- Pump: ISO 2548 class C annex B.
- Motor: according to CEI standards.

A2LD

A4LD

H
[m]

H
[m]

50

20
15

40
30
50-160

25
20

65-160

10
8
6
5
4

80-160

100-200

50-125
40-125

15

80-160
65-160

40-125

50-125

3
2

10
8
6

1
0,8
0,6
0,5

5
4

100-200
50-160

12

24

60

120

180 240
Q [m3/h]

0,6

121

1,2

12

24

60

120

180
Q [m3/h]

A2LD -A4LD 40

CIRCULATION PUMPS
Motor
Power

MODEL

(Kw)
N8020800 A4LD 40 - 125 Y

40

50

75

m /h 2,4

4,5

L/1'
Amp.
n
Q
-1
3x400V 3x230V (min )
3

0,25

0,85

1,46

N8020810 A4LD 40 - 125 X

0,25

0,85

1,46

4 poli

N8020580 A2LD 40 - 125 C

0,75

1,9

3,3

2 poli

N8020590 A2LD 40 - 125 B

1,0

2,4

4,4

2 poli

N8020600 A2LD 40 - 125 A

1,5

3,6

6,2

2 poli

4 poli

Discharge Head
in meters

CODE

100 125 150 175 200 225 250 300 350


PRICE

4,6 4,5

4,1

6,2

6,0

7,5

3,6 3,0

2,2

5,8 5,2

4,5

10,5

12

13,5 15

9,5

20,5 20

19

21

3,9 3,0

16,5 15,5 14,5 13,5 12,3 11

24,5 24 23,5

18

18

17

16

15 11,5 7,5

23

22

21

20 16,5 13

COUNTERFLANGES NOT INCLUDED

MODEL

MOTOR

DN

n d holes e
DN : Flanges

FLANGES mm.

DNa
DNm

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

A4LD 40 - 125 X

71

40 PN10

88

110

150

18

425

100

325

397

200

197

340

130

210

100

41

A4LD 40 - 125 Y

71

40 PN10

88

110

150

18

425

100

325

397

200

197

340

130

210

100

41

A2LD 40 - 125 A

80

40 PN10

88

110

150

18

445

100

345

397

200

197

340

130

210

100

54

A2LD 40 - 125 B

80

40 PN10

88

110

150

18

445

100

345

397

200

197

340

130

210

100

52

A2LD 40 - 125 C

71

40 PN10

88

110

150

18

425

100

325

397

200

197

340

130

210

100

50

122

A2LD -A4LD 50

CIRCULATION PUMPS
MODEL

Motor
Power

(Kw)
N8020820 A4LD 50 - 125 X

L/1' 100 125 150 175 200 225 250 300 350 400 450 500 600
Amp.
n
-1
Q
3x400V 3x230V (min )
3
6

m /h

1,15

0,37

7,5

9 10,5 12 13,5 15 18

21 24 27 30

4 poli

6,3 6,2 6,1 6,0 5,8 5,5 5,2 4,6 3,0


8,8 8,6 8,3 8,0 7,7 7,3 6,9 5,9 4,5

N8020830 A4LD 50 - 160 X

0,5

1,6

2,8

4 poli

N8020610 A2LD 50 - 125 C

1,5

3,6

6,2

2 poli

N8020620 A2LD 50 - 125 B

2,0

4,4

7,7

2 poli

N8020630 A2LD 50 - 125 A

3,0

6,4

11

2 poli

N8020640 A2LD 50 - 160 B

3,0

6,4

11

2 poli

N8020650 A2LD 50 - 160 A

4,0

8,8

15,2

2 poli

Discharge Head
in meters

CODE

PRICE

36

15,5 15 14,1 13 11,8 10,5 7


19 18,5 17,5 16,5 15,5 14,5 10,5
24,5 24 23,5 23
30 29

22 20,5 17

28 26,5 25

23

18

36,5 35,5 34,5 33,5 32,5 3

27

COUNTERFLANGES NOT INCLUDED

MODEL

MOTOR

DN

n d holes e
DN : Flanges

FLANGES mm.

DNa
DNm
a

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

A4LD 50 - 125 X

71

50 PN10 102

125

165

18

435

110

325

427

217

210

365

145

220

105

46

A4LD 50 - 160 X

71

50 PN10 102

125

165

18

435

110

325

480

245

235

410

170

240

120

52

A2LD 50 - 125 A

90

50 PN10 102

125

165

18

495

110

385

427

217

210

365

145

220

105

66

A2LD 50 - 125 B

80

50 PN10 102

125

165

18

455

110

345

427

217

210

365

145

220

105

58

A2LD 50 - 125 C

80

50 PN10 102

125

165

18

455

110

345

427

217

210

365

145

220

105

56

A2LD 50 - 160 A

80

50 PN10 102

125

165

18

455

110

345

427

217

210

365

145

220

105

56

A2LD 50 - 160 B

100

50 PN10 102

125

165

18

535

110

425

480

245

235

410

170

240

120

86

123

A2LD -A4LD 65

CIRCULATION PUMPS
CODE

MODEL

Motor
Power

(Kw)

L/1' 200 225 250 300 350 400 450 500 600 700 800 900 1000
Amp.
n
Q
-1
3x400V 3x230V (min )
m3/h 12 13,5 15 18 21 24 27 30 36 42 48 54 60

0,55

1,6

2,7

4 poli

6,7 6,6 6,4 6,1 5,7 5,1 4,3 3,3

N8020850 A4LD 65 - 160 Y

0,75

3,5

4 poli

8,2 8,0 7,9 7,7 7,4 7,0 6,6 6,0 4,0

N8020860 A4LD 65 - 160 X

0,9

2,4

4,2

4 poli

N8020660 A2LD 65 - 160 D

6,4

11

2 poli

N8020670 A2LD 65 - 160 C

8,8

15,2

2 poli

N8020680 A2LD 65 - 160 B

5,5

11,3

2 poli

N8020700 A2LD 65 - 160 A

7,5

17,3

2 poli

Discharge Head
in meters

N8020840 A4LD 65 - 160 Z

PRICE

9,0 8,9 8,8 8,6 8,4 8,1 7,7 7,2 5,5


23 22,5 22 21,5 19,8 17,5 15
26,5 26 25,5 24,3 22,6 20,2 18
32,5 32 31,5 30,5 29,5 28
37 36,5 36

35

26 23,5

34 32,5 31

29

COUNTERFLANGES NOT INCLUDED

MODEL

MOTOR

DN

n d holes e
DN : Flanges

FLANGES mm.

DNa
DNm

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

A4LD 65 - 160 X

80

65 PN10

122

145

185

18

475

130

345

543

275

268

450

180

270

140

67

A4LD 65 - 160 Y

80

65 PN10

122

145

185

18

475

130

345

543

275

268

450

180

270

140

65

A4LD 65 - 160 Z

80

65 PN10

122

145

185

18

475

130

345

543

275

268

450

180

270

140

65

A2LD 65 - 160 A

90

65 PN10

122

145

185

18

495

110

385

480

245

235

410

170

240

120

67

A2LD 65 - 160 B

132

65 PN10

122

145

185

18

670

130

540

543

275

268

450

180

270

140

125

A2LD 65 - 160 C

100

65 PN10

122

145

185

18

565

130

435

543

275

268

450

180

270

140

101

A2LD 65 - 160 D

90

65 PN10

122

145

185

18

485

130

345

543

275

268

450

180

270

140

81

124

A2LD -A4LD 80

CIRCULATION PUMPS
CODE

Motor
Power

MODEL

(Kw)
N8020870 A4LD 80 - 160 W

L/1' 300 350 400 450 500 600 700 800 900 1000 1250 1500 1750 2000 2250
Amp.
n
Q
3x400V 3x230V (min-1)
m3/h 18 21 24 27 30 36 42 48 54 60 75 90 105 120 135
2,25

3,9

4 poli

6,3 6,2 6,1 5,9 5,6 4,9 4,1 3,2

0,9

2,7

4,7

4 poli

7,3 7,2 7,1

N8020890 A4LD 80 - 160 Y

1,1

2,6

4,5

4 poli

N8020900 A4LD 80 - 160 X

1,5

3,5

6,1

4 poli

N8020690 A2LD 80 - 160 D

7,5

17,3

2 poli

N8020710 A2LD 80 - 160 C

10

22,5

2 poli

N8020720 A2LD 80 - 160 B

12,5

27

2 poli

N8020730 A2LD 80 - 160 A

15

32

2 poli

Discharge Head
in meters

0,75

N8020880 A4LD 80 - 160 Z

6,8 6,3 5,6 4,8 3,9

8,6 8,5 8,4 8,3 8,2 8,0


10,2 10,1 10

PRICE

7,5 6,8 6,0 5,0

9,9 9,8 9,4 9,0 8,5 7,7 6,5


25 24,9 24,1 23,4 20,5 17 12,7
30,5 30 29,5 29 26,5 24 20,5 16
27

23

19

41 40,5 40 39,5 38 35,5 33

29

24

36,5 36 35,5 34,5 33

30

COUNTERFLANGES NOT INCLUDED

MODEL

MOTOR

DN

n d holes e
DN : Flanges

FLANGES mm.

DNa
DNm

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

A4LD 80 - 160 X

90

80 PN10

138

160

200

18

535

150

385

550

280

270

510

205

305

135

83

A4LD 80 - 160 Y

90

80 PN10

138

160

200

18

535

150

385

550

280

270

510

205

305

135

79

A4LD 80 - 160 Z

80

80 PN10

138

160

200

18

485

150

335

550

280

270

510

205

305

135

74

A4LD 80 - 160 W

80

80 PN10

138

160

200

18

485

150

335

550

280

270

510

205

305

135

72

A2LD 80 - 160 A

112

80 PN10

138

160

200

18

565

130

435

543

275

268

450

180

270

140

110

A2LD 80 - 160 B

132

80 PN10

138

160

200

18

690

150

540

550

280

270

510

205

305

135

175

A2LD 80 - 160 C

132

80 PN10

138

160

200

18

690

150

540

550

280

270

510

205

305

135

162

A2LD 80 - 160 D

132

80 PN10

138

160

200

18

690

150

540

550

280

270

510

205

305

135

141

125

A2LD -A4LD 100

CIRCULATION PUMPS
CODE

MODEL

Motor
Power

(Kw)

L/1' 500
Amp.
n
-1
3x400V 3x230V (min ) Q 3
m /h 30

600 700 800 900 1000 1100 1200 1300 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000
36

42

48

54

60

66

72

78

6,5

5,3 4,6

90

105 120 135 150 165 180 195 210 225 240

N8020910

A4LD 100 - 200W

1,5

3,8

6,6

4 poli

N8020920

A4LD 100 - 200Z

2,2

5,1

8,9

4 poli

N8020930

A4LD 100 - 200Y

3,0

6,9

12

4 poli

N8020940

A4LD 100 - 200X

4,0

9,2

16

4 poli

N8020760

A2LD 100 - 200D

10

38

2 poli

N8020770

A2LD 100 - 200C

12,5

44,5

2 poli

N8020780

A2LD 100 - 200B

15

58

2 poli

N8020790

A2LD 100 - 200A

15

71

2 poli

N8020740

A2LD 100 - 200F

12,5

27

2 poli

32,1 31 29 27 24,5 22 19

N8020750

A2LD 100 - 200E

15

32

2 poli

37,3 36,5 35 33

8,2 7,8 7,4

10 9,7 9,3 8,9 8,5 8,0 7,5 7,0 6,0


Discharge Head
in meters

12 11,7 11,5 11,3 11 10,5 10 9,5 8,5 7,0


14,5 14,2 14 13,8 13,5 13,1 12,7 12,2 11 9,0 6,5
23,3 22 20,5 18,5 16 13,5 10,5 7
26,2 25,5 24 22

20 17,5 15

12 8,6

27,8 27 25,5 23,5 21,5 19 16,5 13,8 10,8 7,5

29 28 26 24,5 22 20 17,5 14 11,3 7,5 3,5

31 28,5 26

COUNTERFLANGES NOT INCLUDED

MODEL

MOTOR

DN : Flanges

DN

n d holes e

FLANGES mm.

DNa
DNm

WEIGHT (kg)

OVERALL DIMENSIONS (mm)

A4LD 100 - 200 X

112

100 PN10

158

180

220

18

615

180

435

670

325

345

630

240

390

165

150

A4LD 100 - 200 Y

100

100 PN10

158

180

220

18

605

180

425

670

325

345

630

240

390

165

138

A4LD 100 - 200 Z

100

100 PN10

158

180

220

18

605

180

425

670

325

345

630

240

390

165

130

A4LD 100 - 200 W

90

100 PN10

158

180

220

18

535

180

355

670

325

345

630

240

390

165

110

A2LD 100 - 200 E

132

100 PN10

158

180

220

18

720

180

540

670

325

345

630

240

390

165

162

A2LD 100 - 200 F

132

100 PN10

158

180

220

18

720

180

540

670

325

345

630

240

390

165

162

A2LD 100 - 200 D

132

100 PN10

158

180

220

18

720

180

540

670

325

345

630

240

390

165

162

A2LD 100 - 200 C

132

100 PN10

158

180

220

18

720

180

540

670

325

345

630

240

390

165

162

A2LD 100 - 200 B

132

100 PN10

158

180

220

18

720

180

540

670

325

345

630

240

390

165

162

A2LD 100 - 200 A

132

100 PN10

158

180

220

18

720

180

540

670

325

345

630

240

390

165

162

126

ACCESSORIES FOR CIRCULATION PUMPS


BRASS UNIONS
CODE

DESCRIPTION

MATERIAL

UNION
(PIPE END)

RING NUT

B7012KKK

3/4F

1 1/2

B7016KKK

3/4F

1 1/4

B7013KKK

1F

1 1/2

1F L

1 1/2

B7014KKK

1 1/4 M

1 1/2

B7015KKK

1 1/4 F

Two brass unions


and gaskets

B7009KKK

PRICE

Brass

CIRCULAR FLANGES
CODE

MATERIAL

DESCRIPTION

B7058KKK

TYPE

To be
welded

B7098KKK
B7047KKK

Threaded
B7097KKK

B7059KKK

To be
welded

ZB901890
B7048KKK

B
Threaded

B7050KKK
B7060KKK
B7075KKK

Fig. 1

Steel

B7049KKK
B7051KKK
B7061KKK

To be
welded
Threaded

Kit including 2 circular flanges,


bolts and gaskets.

To be
welded

ZB901910
B7054KKK

Threaded
ZB901900
B7062KKK

To be
welded

ZB901920

SPEC

N F

PN

100

14

PN 6

DN 40 UNI 2280

110

19

PN 16

DN 40 UNI 2282

100

14

PN 6

11/2

UNI 2253

110

19

PN 16

1 /2

UNI 2254

110

14

PN 6

DN 50 UNI 2280

145

18

PN 16

DN 50 UNI 2282

110

14

PN 6

UNI 2253

125

18

PN 16

UNI 2254

130

14

PN 6

DN 65 UNI 2280

145

18

PN 16

DN 65 UNI 2282

130

14

PN 6

21/2

UNI 2253

125

18

PN 16

2 /2

UNI 2254

150

19

PN 6

DN 80 UNI 2280

160

18

PN 16

DN 80 UNI 2282

150

18

PN 6

UNI 2253

160

18

PN 16

UNI 2254

170

19

PN 6 DN 100 UNI 2280

180

18

PN 16 DN 100 UNI 2282

DN

PRICE

BLIND FLANGES
MATERIAL

INT

N F

Fe 360

105

G20

133,5

8,5

B7230KKK

G20

180

11

ZB901860

Fe 360

112

CODE

DESCRIPTION

B7241KKK
B7231KKK

Blind Flange

128

PRICE

ACCESSORIES FOR IN LINE CIRCULATION PUMPS

BRASS UNIONS
ACCESSORY

CIRCULAR FLANGES
BRASS UNIONS

CIRCULAR FLANGES

UNION (pipe end)

Ring nut

11/2 11/4 11/2 11/2 11/2 2

/4F 3/4F 1F 1FL 11/4M 11/4F 11/2 11/2 DN 40 DN 40 2

3 DN 80 DN 80 DN 100 DN 100

B7241KKK

B7230KKK

B7231KKK

ZB901860

B7062KKK

ZB901920

B7061KKK

ZB901910

ZB901900

B7054KKK

B7051KKK

B7049KKK

B7075KKK

B7060KKK

ZB901890

B7059KKK

B7050KKK

B7048KKK

B7058KKK

B7098KKK

B7047KKK

B7097KKK

B7015KKK

B7014KKK

B7009KKK

B7013KKK

B7016KKK

B7012KKK

CODE

BLIND FLANGES

2 DN 50 DN 50 DN 65 DN 65 21/2 21/2

PN 16 PN 6 PN 16 PN 6 PN 6 PN 16 PN 6 PN 16 PN 6 PN 16 PN 6 PN 16 PN 6 PN 16 PN 16 PN 6 PN 16 PN 6

Nom. Pressure

TYPE

BLIND FLANGES

SR3
SR3/RS2 25

R2X 20
R2B 30
R2B 32/R2B 40
R2S (D) 32
R2S (D) 40
R2S 40 F
R2S (D) 42 F
R2C/R4C (D) 40

R2CD 50-60/R4CD 50-30


R2C/R4C (D) 50

R2CD 65-60/R4CD 65-30


R2C/R4C (D) 65

R2C/R4C (D) 80 PN6

R4C (D) 100 PN16

R2T/R4T (D) 50

R4T (D) 65-30


R2T/R4T (D) 65

R2T/R4T (D) 80 PN6


R2T/R4T (D) 80 PN16

A2L/A4L (D) 65
A2L/A4L (D) 80
A2L/A4L (D) 100

"PREVIOUS MODEL
129

R2T/R4T (D) 100 PN16

A2L/A4L (D) 50

"

R2T/R4T (D) 100 PN6

A2L/A4L (D) 40

R4C (D) 100 PN6

R4T (D) 50-30

"
"

R2C/R4C (D) 80 PN16

R2T/R4T (D) 40

SUMP SEWAGE AND EFFLUENT PUMPS


50 Hz

DRENOX

SUMP SEWAGE AND EFFLUENT PUMPS


SUBMERSIBLE SUMP PUMPS FOR
DRAINING CLEAR WATER
The DRENOX series pumps are built entirely in AISI
304 stainless steel. Cooling of the motor is via a heat
exchange chamber that allows the machine to work
for long periods when not completely submerged.
Design Features
- Stainless steel pump casing
- Stainless steel suction grid
- Cast stainless steel impeller (technopolymer on
request for model 80/7)
- 10 m H07 RN-F power supply cable with plug
- Fixed double NBR 70 rubber seal with special sand
guard V-ring
- Oil chamber for seal lubrication
- Stainless steel shaft with a ceramic facing at the
points of seal wear
- Equipped with 32 mm rubber holder
- Supplied with float level switch in the AUTOMATIC
versions
- Suitable for continuous use

12
10

Motor
- Dry motor with stainless steel casing
- Level of protection IP68
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Three phase power supply with external protection
provided by the user
- Completely insulated cable connection chamber
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm

/1 2

250
/10

16

0/ 8

80
/7

Usage Limitations
- Type of liquid: partially effluent and dirty clear water,
non-aggressive liquids
- Maximum liquid temperature 40C
- Maximum submersion under the water level 7m
- Minimum drainage level 3 mm for model 80/7, 35 mm
for the remaining models (manual version)
- Free clearance of solids 3 mm for models 80/7, 6 mm
for the remaining models

350

2
Hm
Q

50
3

L / 1'
m3/ h

250
15

200
12

150
9

100
6

300
18

Applications
- Drainage of seepage water, pumping of rain water,
from a grating or drain, pumping of domestic waste
water, drainage of environments, bathing and
swimming pools, industrial applications
- Fountains and water features
- Surface irrigation
Dimensions mm.

Model
B

Weight

Free Clearance

DNM

kg.

1/4"

5,7
6,5

DRENOX 80/7

231

61

177

DRENOX 160/8

300

94

177

1 1/4"
1/4"

DRENOX 250/10

338

94

177

DRENOX 350/12

338

94

177

1 1/4"

MODEL

N1031010
N1031050
N1031090
N1031100
N1031020
N1031060
N1031030
N1031070
N1031040
N1031080

DRENOX 80/7 N *
DRENOX 80/7 N AUT *
DRENOX 80/7
DRENOX 80/7 AUT
DRENOX 160/8
DRENOX 160/8 AUT
DRENOX 250/10
DRENOX 250/10 AUT
DRENOX 350/12
DRENOX 350/12 AUT

N1031110

DRENOX 350/12 T

Nominal
Power

Absorbed
Power

L/1'

VOLTAGE

Amp.

F.

m /h

HP

kW

HP

kW

0,3

0,2

0,4

0,3

1 ~ 220 240 V

1,3

6,3

0,3

0,2

0,4

0,3

1 ~ 220 240 V

1,3

6,3

0,55

0,40

0,75

0,55 1 ~ 220 240 V

2,4

0,75

0,55

1,2

0,9

1 ~ 220 240 V

4,5

10

1,1

0,8

1,6

1,2

1 ~ 220 240 V

5,1

16

1,1

0,8

1,6

1,2

3 ~ 400 V

* TECHNOPOLYMER IMPELLER

132

10

40

60

80

120 160 240 300

0,6

2,4

3,6

4,8

7,2

6,5

6,5

5,8

4,1

2,2

9,4

8,5

7,6

7,2

5,1

4,1

10,5

10

9,5

7,7

6,5

3,4

10,5

10

9,5

7,7

6,5

3,4

Discharge Head
in meters

CODE

7
8,5

PRICE
9,6 14,4

18

OMNIA

SUMP SEWAGE AND EFFLUENT PUMPS


SUBMERSIBLE SUMP PUMPS FOR
DIRTY WATER
The OMNIA series pumps are made entirely of AISI
304 stainless steel. Cooling of the motor is via a heat
exchange chamber that allows the machine to work
for long periods when not completely submerged.
Design Features
- Stainless steel pump casing
- Stainless steel suction grid
- Cast stainless steel impeller (technopolymer on
request for model 80/5)
- 10 m H07 RN-F power supply cable with plug
- Fixed double NBR 70 rubber seal
- Oil chamber for seal lubrication
- Stainless steel shaft with a ceramic facing at the
points of seal wear
- Equipped with 32 mm rubber holder
- Supplied with float level switch in the AUTOMATIC
versions
- Suitable for continuous use

6
20

0/8

16

Motor
- Dry motor with stainless steel casing
- Level of protection IP68
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Completely insulated cable connection chamber
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm

0/7

4
80

/5

2
Hm

Usage Limitations
- Type of liquid: waste water with solids
- Maximum liquid temperature 40C
- Maximum submersion under the water level 7m
- Minimum drainage level 35 mm (manual)
- Free clearance of solids 20 mm

100
6

50
3

L / 1'
m3/ h

150
9

200
12

Applications
- Pumping of domestic waste water, draining of
environments, bathing and swimming pools, industrial
applications
- Fountains and water features
- Surface irrigation

Dimensions mm.

Model
A

Weight
Free Clearance

DNM

kg

1 /4 "

6,1

OMNIA 80/5

264

94

177

20

OMNIA 160/7

300

94

177

20

1 1 /4 "

20

1 /4 "

CODE

338

MODEL

94

Nominal
Power

Absorbed
Power

HP

kW

HP

kW

VOLTAGE

177

Amp. F.

N2081070
N2081090

OMNIA 80/5
OMNIA 80/5 AUT

0,3

0,2

0,4

0,3

1 ~ 220 240 V

1,4

N2081020
N2081110

OMNIA 160/7
OMNIA 160/7 AUT

0,5 0,37

0,7

0,5

1 ~ 220 240 V

2,5

N2081030
N2081100

OMNIA 200/8
OMNIA 200/8 AUT

0,7

0,75 1 ~ 220 240 V

3,2

0,5

* TECHNOPOLYMER IMPELLER

133

8,5

L/1'

10

40

70

100

140

200

m3/h

0,6

2,4

4,2

8,4

12

4,1

2,7

5,5

2,8

7,8

6,3

5,4

4,1

2,7

PRICE

Discharge Head
in meters

OMNIA 200/8

0,5

SOM

SUMP SEWAGE AND EFFLUENT PUMPS


SUBMERSIBLE PUMPS FOR DENSE
LIQUIDS WITH HELICAL IMPELLER
The SOM pumps are submersible pumps for drainage
that work on the principle of a water scooping machine
and are designed for continuous and heavy use in
fixed installations.
Design Features
- Cast iron pump casing
- Helical impeller in AISI 316 stainless steel
- 10 m dual insulated 4 x 2.5 power supply cable
- Mechanical seal with tungsten carbide (widia)
counterface and double NBR 70 rubber lip seal ring
- Oil chamber for seal lubrication
- Stainless steel shaft, bolts and nuts
- Flanged outlet connection and threaded round
counterflange - 3" female
- Suitable for continuous use
Motor
- Motor in dielectric oil bath
- Level of protection IP68
- Class F insulation
- Cable connection chamber in oil bath
- Three phase power supply with external protection
provided by the user
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
Usage Limitations
- Type of liquid: dense and muddy
- Maximum liquid temperature 40C
- Maximum submersion under the water level 7m
- Minimum drainage level 110 mm (manual version)
- Free clearance of solids 25 mm

DNM

Applications
- Marble processing industry, quarries, ceramics, paper
mills and in agriculture for handling sewage and
surface irrigation and for all typical building applications
- Draining of muddy and marshy land

D
SOM

Dimensions mm.

Model

Weight

DNM

kg

SOM 2 B

110

690

295

290

3"

54

SOM 2 A

110

690

295

290

3"

55

SOM 3

110

740

295

290

3"

60

MODEL

Nominal
Power

Absorbed
Power

HP

kW

HP

kW

L/1'

VOLTAGE

Amp.

m /h

N1061010

SOM 2 B

2,2

3,8

2,8

3 ~ 400 V

5,2

N1062010

SOM 2 A

2,2

3,8

2,8

3 ~ 400 V

5,2

N1063010

SOM 3

4,8

3,5

3 ~ 400 V

134

200 400 600 800 1000 1200

Discharge Head
in meters

CODE

PRICE
12

24

36

48

60

6,7

2,5

9,5

5,7

12

7,5

5,7

3,7

72

PRIOX

SUMP SEWAGE AND EFFLUENT PUMPS


SUBMERSIBLE EFFLUENT VORTEX
PUMPS FOR DIRTY WATER
The PRIOX series pumps are made entirely of AISI 304
stainless steel. They work completely submerged in the
pumped liquid that cools the motor externally.
Manufactured on the vortex operating principle with the
impeller set back.
Design Features
Stainless steel pump casing
Suction base with stainless steel feet
Self-cleaning cast stainless steel impeller
10m H07 RN-F power supply cable with plug
(without plug for the three phase versions)
Sic/Sic mecchanical seal and NBR 70
rubber lip seal with special sand guard V-ring
Oil chamber for seal lubrification
Stainless steel shaft
Supplied with float level swith in the AUTOMATIC
versions
Threaded 2 male connector outlet mouth
(1 1/2 model 250/8)
Motor
Dry motor
Level of protection IP 68
Class F insulation
Single phase power supply with capacitor permanently
activated and thermal protection built into the motor
winding
Three phase power supply with external protection
under care of the user (control panel on request)
Completely insulated cable connection chamber
Self-lubrificating ball bearings
Speed of rotation 2850 rpm

14
12
10
8

30

11

13

13

0/

0/

25

Applications
All applications of pumping and draining effluent, civil
and industrial sewage with suspended solids
Pumping stations with one or more pumps for civil
and industrial plants

0/

0/

0/

46

42

Usage Limitations
Type of liquid: waste water and sewage with solids
Maximum liquid temperature 40C.
Maximun submersion under the water level 7m
Minimum drainage level 60 mm (manual version)
Free clearance of solids 40 mm
(PRIOX 600/13 - 50mm)

60

Hm
Q

100
6

L / 1'
m3/ h

200
12

400
24

300
18

Dimensions mm.

Model

600
36

500
30

Weight

Free Clearance

DNM

kg

PRIOX 250/8

420

122,5

235

40

1"1/2

9,4

PRIOX 300/9

420

122,5

235

40

2"

9,6

PRIOX 420/11

450

122,5

235

40

2"

11,2

PRIOX 460/13

450

122,5

235

40

2"

11,7

450

122,5

235

50

2"

12,6

PRIOX 600/13

MODEL

Nominal
Power
HP

N2110100
N2110110

PRIOX 250/8 M
PRIOX 250/8 M AUT

N2110040
N2110050

PRIOX 300/9 M
PRIOX 300/9 M AUT

0,8

N2110090
N2110020
N2110030
N2110080
N2110000
N2110010
N2110070

PRIOX 300/9 T
PRIOX 420/11 M
PRIOX 420/11 M AUT
PRIOX 420/11 T
PRIOX 460/13 M
PRIOX 460/13 M AUT
PRIOX 460/13 T

0,8
1,2

N2110060

PRIOX 600/13 T

kW

Absorbed
Power
HP

VOLTAGE

Amp.

F.

L/1'

50

12

15

m /h

kW

1,0

0,7

1 ~ 230 V

0,6

1,2

0,9

0,6

1,2

0,6

0,9

1,8

1,2

0,9

1,6

100 150 200 250 300 400 500 550

PRICE
18

24

3,15

14,0

6,5

5,2

3,4

2,0

0,2

1 ~ 230 V

4,1

12,5

7,7

6,4

3,8

2,3

3 ~ 400 V

1,55

7,7

6,4

3,8

2,3

1,3

1 ~ 230 V

10

7,8

6,3

3,8

1,8

1,3

3 ~ 400 V

2,3

1,2

2,3

1,7

1 ~ 230 V

7,5

11,8 10,8 9,8

8,5

5,5

1,6

1,2

2,3

1,7

3 ~ 400 V

2,7

1,8

1,3

2,5

1,8

3 ~ 400 V

0,7

0,5

20

20

Discharge Head
in meters

CODE

12,8 12,2 11,3 10,3 9,3

135

5,5

30

33

1,8

MINIVORT P

SUMP SEWAGE AND EFFLUENT PUMPS


SUBMERSIBLE SEWAGE PUMPS WITH VORTEX IMPELLER
The MINIVORT P pumps are made entirely of cast iron and designed for continuous use in
fixed installations. Manufactured on the vortex operating principle with the impeller set back.
Design Features
- Cast iron pump casing
- Self-cleaning cast iron impeller
- Automatic single phase version with float switch and sealed electric panel including capacitor,
thermal protection and manual/automatic switch. 10 m H07 RN-F power supply cable
- Three phase version, 10 m H07 RN-F power supply cable
- Single phase version with panel complete with capacitor and 10 m H07 RN- F power supply
cable
- Mechanical graphite seal with ceramic counterface and NBR 70 rubber lip seal
- Oil chamber for seal lubrication
- Stainless steel shaft
- Flanged outlet connection, with square threaded
counterflange - 2" female
14
Motor
- Dry motor
- Level of protection IP68
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Three phase power supply with external protection
provided by the user
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
- Four pole 1450 rpm (P2) motor (P4).

12

P2
-2

10
P21 ,5

P2 -

1
P 4 -1

6
4

Usage Limitations
- Type of liquid: waste water and sewage
- Maximum liquid temperature 40C
- Maximum submersion under the water level 7m
- Minimum drainage level 45mm (manual version)
- Free clearance of solids 52 mm

2
Hm
Q

100
6

L / 1'
m3/ h

200
12

400
24

300
18

700
42

DNM

Applications
- Pumping and draining effluent; civil and industrial
sewage with suspended solids
- Draining of cesspits, cesspools, handling of effluent
- Pumping stations with one or more pumps
for civil and industrial plants

600
36

500
30

Dimensions mm.

Model

Weight

DNM

kg

MINIVORT P2 - 1

45

440

85

235

2"

27

MINIVORT P2 - 1,5

45

440

85

235

2"

27

MINIVORT P2 - 2

45

440

85

235

2"

28

MINIVORT P4 - 1

45

440

85

235

2"

27

MODEL

Nominal
Power

Absorbed
Power

L/1'

VOLTAGE

Amp.

F.

m /h

HP

kW

HP

kW

0,75

1,5

1 ~ 220 240 V
1 ~ 220 240 V
3 ~ 400 V

6,5
6,5
2,3

20
20

N2041010
N2041020
N2041030

MINIVORT P2 - 1 M
MINIVORT P2 - 1 M AUT
MINIVORT P2 - 1 T

N2042010
N2042020
N2042030

MINIVORT P2 - 1,5 M
MINIVORT P2 - 1,5 M AUT 1,5
MINIVORT P2 - 1,5 T

1,1

2,2

1,6

1 ~ 220 240 V
1 ~ 220 240 V
3 ~ 400 V

7
7
2,7

25
25

N2043010
N2043020
N2043030

MINIVORT P2 - 2 M
MINIVORT P2 - 2 M AUT
MINIVORT P2 - 2 T

1,5

2,2

1 ~ 220 240 V
1 ~ 220 240 V
3 ~ 400 V

9,8
9,8
3,2

35
35

N2044010
N2044020
N2044030

MINIVORT P4 - 1 M
MINIVORT P4 - 1 M AUT
MINIVORT P4 - 1 T

0,75

1,7

1 ~ 220 240 V
1,25 1 ~ 220 240 V
3 ~ 400 V

5,5
5,5
2,3

25
25

136

50

100 200 300 400 500

Discharge Head
in meters

CODE

PRICE
30

12

18

24

5,4

4,1

8,3

7,5

6,1

4,6

2,8

3,7

12,1 11,3 9,8

4,6

3,3

2,2

MINIVORT PP

SUMP SEWAGE AND EFFLUENT PUMPS


SUBMERSIBLE SEWAGE PUMPS WITH VORTEX IMPELLER
The MINIVORT PP pumps are made entirely of cast iron and designed for continuous use
in fixed installations. Manufactured on the vortex operating principle with the impeller set
back.
Design Features
- Cast iron pump casing
- Self-cleaning cast iron impeller
- Automatic single phase version with float switch and sealed electric panel including
capacitor, thermal protection and manual/automatic switch. 10 m H07 RN-F power
supply cable
- Three phase version, 10 m H07 RN-F power supply cable
- Single phase version with panel complete with capacitor and 10 m H07 RN-F
power supply cable
- Mechanical graphite seal with ceramic counterface
and NBR 70 rubber lip seal
- Oil chamber for seal lubrication
12
- Stainless steel shaft
- Flanged outlet connection, with square threaded
counterflange - 2 1/2" female

10

Motor
- Dry motor
- Level of protection IP68
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Three phase power supply with external protection
provided by the user
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm

PP
2-2

6
PP

2 -1
,5
PP
2-1

4
2

Usage Limitations
- Type of liquid: waste water and sewage
- Maximum liquid temperature 40C
- Maximum submersion under the water level 7m
- Minimum drainage level 72mm (manual version)
- Free clearance of solids 58 mm

Hm
Q

L / 1'
m3/ h

100
6

200
12

300
18

600
36

400 500
24
30

800
48

900
54

DNM

Applications
- Pumping and draining effluent; civil and industrial
sewage with suspended solids
- Draining of cesspits, cesspools, handling of effluent
- Pumping stations with one or more pumps
for civil and industrial plants
- On request, connecting foot to facilitate
installations and maintenance

700
42

Dimensions mm.

Model

MINIVORT PP2 - 1

Weight

DNM

Kg

72

475

115

325

2 1/2"

30

1/2"

31
33

MINIVORT PP2 - 1,5

72

475

115

325

MINIVORT PP2 - 2

72

475

115

325

2 1/2"

MODEL

Absorbed
power

HP

kW

HP

kW

L/1'

VOLTAGE

Amp.

F.

MINIVORT PP2 - 1 M
MINIVORT PP2 - 1 M AUT
MINIVORT PP2 - 1 T

0,75

1,5

1 ~ 220 240 V
1 ~ 220 240 V
3 ~ 400 V

6,2
6,2
2,3

20
20

N2052010
N2052020
N2052030

MINIVORT PP2 - 1,5 M


MINIVORT PP2 - 1,5 M AUT 1,6
MINIVORT PP2 - 1,5 T

1,2

2,5

1,8

1 ~ 220 240 V
1 ~ 220 240 V
3 ~ 400 V

8,2
8,2
3

25
25

N2053010
N2053020
N2053030

MINIVORT PP2 - 2 M
MINIVORT PP2 - 2 M AUT
MINIVORT PP2 - 2 T

1,5

2,2

1 ~ 220 240 V
1 ~ 220 240 V
3 ~ 400 V

9,8
9,8
3,5

35
35

PRICE
3

m /h

N2051010
N2051020
N2051030

137

100 200 300 400 600 800

Discharge Head
in meters

CODE

Nominal
Power

12

18

24

1,6

6,7

5,7

4,6

3,3

10

9,3

8,2

4,2

36

48

SOMVORT

SUMP SEWAGE AND EFFLUENT PUMPS


SUBMERSIBLE SEWAGE PUMPS
WITH VORTEX IMPELLER
The SOMVORT pumps are made entirely of cast iron
and designed for continuous use in fixed installations.
Manufactured on the vortex operating principle with
the impeller set back.
Design Features
- Cast iron pump casing
- Bronze vortex impeller
- 10 m dual insulated 4 x 2.5 power supply cable
- Tungsten carbide mechanical seal and counterface
(widia) and double NBR 70 rubber lip seal ring
- Oil chamber for seal lubrication
- Stainless steel shaft, bolts and nuts
- Flanged outlet connection, with round threaded
counterflange - 3" female

Motor
- Motor in dielectric oil bath
- Level of protection IP68
- Class F insulation
- Cable connection chamber in oil bath
- Three phase power supply with external protection
provided by the user
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
- Suitable for continuous use

SOM
VOR
T
4

Usage Limitations
- Type of liquid: suspended and also fibrous solids
- Maximum liquid temperature 40C
- Maximum submersion under the water level 7m
- Minimum drainage level 105mm (manual version)
- Free clearance of solids 75 mm

Hm

Applications
- Pumping and draining effluent, civil and industrial
sewage with suspended solids
- Draining of cesspits, cesspools, handling of effluent
- Pumping stations with one or more pumps for civil
and industrial plants

L / 1'
m3/ h

100
6

300
18

700
42

500
30

900
54

1100
66

DNM

Dimensions mm.

Model

SOMVORT

CODE

N2061010

MODEL

SOMVORT

Weight

DNM

kg

105

710

250

290

3"

56

Nominal
Power

Absorbed
Power

HP

kW

HP

kW

4,8

3,5

L/1'

VOLTAGE

Amp.

PRICE
3

3 ~ 400 V

138

100 300 500 700 900

Q
m /h

18

30

42

54

Discharge
Head
in meters

5,5

4,5

3,5

2,5

SUMP SEWAGE AND EFFLUENT PUMPS


VITEX SB SUBMERSIBLE PUMPS FOR
MOBILE INSTALLATIONS
Electric submersible pumps that, with their special screw
impeller, are the ideal solution in all those situations where
the pumped liquid contains suspended solids or fibrous
substances.
Design Features
- Pump casing in G20 (UNI 5007) cast iron
- Impeller in nodular cast iron - GS 400-12 ( UNI 4544)
- X30 Cr13 chrome steel shaft
- Motor casing in G20 (UNI 5007) cast iron
- Double mechanical seal:
upper widia/widia (for all models)
lower widia/widia or ceramic/graphite
MIM ring (for AC-AD-CD only)
- Connections:
threaded (models AC - AD 50)
flanged
(DN 50 - DN 100)
- Versions for mobile installations (SB)
Motor
- Class F insulation
- Level of protection IP68
- Power supply voltage: three phase 3 x 230 - 400V 50Hz
single phase 1 x 230 V 50Hz (for models AC and AD only)
- Direction of rotation: clockwise (motor end view)
- 10 m electric cable (type H07 RN-F)
Usage Limitations
- Liquid temperature 25C (max 45C for intermittent use)
- Max installation depth: 20 m
Applications
- Rain and sewage water in general
- Waste water (industrial or civil)
- Purification systems
- Tanneries and slaughterhouse waste
- Liquid slurry and digested sludge
- Wood pulps and cellulose
- Dense liquid pulps (food and pharmaceutical industries)
- Transport of fruit and vegetables in an aqueous medium
- Fish industry
- Beer and sugar making industries
- Textile industry

Screw impeller

139

VITEX SB

SUMP SEWAGE AND EFFLUENT PUMPS

Free Bore

(mm.)

B2

K1

P2

Q (nx)

WEIGHT
(kg)

AC 50/2 SB

52

2"

237

518

53

260

3 x 18

400

233

465

36

30

AD 50/2 SB

52

2"

237

518

53

260

3 x 18

400

233

465

38

28

AC 55/2 SB

50

50

165

237

518

53

260

3 x 18

400

280

465

36

30

AD 55/2 SB

50

50

165

237

518

53

260

3 x 18

400

280

465

38

28

CODE
F2602KKK

OVERALL DIMENSIONS (mm)

MODEL

Electric cable
l/1' 0
Mot. Pow. VOLTAGE
n
Amp.
(V) 1x230V 3x400V (rpm) (n.cond. x cable) Q m3/h 0
HP kW
direct
Y/
1x230

F2590KKK AC 50/2 SB 1,00 0,75 3x230


F2603KKK

3x400

F2600KKK

1x230

F2591KKK AD 50/2 SB 1,50 1,10 3x230


F2601KKK

2,3

2900 4x1,5+

5,5

2,5

2900 4x1,5+

5,2

2,3

2900 4x1,5+

5,5

2,5

2900 4x1,5+

3x400

F2570KKK

1x230

F2571KKK

AC 55/2 SB 1,00 0,75 3x230

F2572KKK

3x400

F2580KKK

1x230

F2581KKK AD 55/2 SB 1,50 1,10 3x230


F2582KKK

5,2

3x400

Power supply cable for control signals 2x1,5 mm2

140

50
3

11,2 10,5

Diacharge Head
in meters

MODEL

100 200 300 400 450


6

12

18

24

27

9,6 7,5 5,2

2,9 1,8

14,0 13,4 12,4 9,8 6,4

3,4 2,2

11,2 10,5

9,6 7,5 5,2

2,9 1,8

14,0 13,4 12,4 9,8 6,4

3,4 2,2

PRICE

VITEX AC-AD

141

SUMP SEWAGE AND EFFLUENT PUMPS

MODEL

OVERALL DIMENSIONS (mm)

WEIGHT
(kg)

Free Bore

(mm.)

B2

K1

P2

Q (nx)

CD 80/2 SB

95

80

200

315

838

63

360

3 x 18

650

377

725

124

58

CE 80/2 SB

95

80

200

315

967

113

360

3 x 18

650

377

854

235

60

CD 80/4 SB

95

80

200

315

674

113

360

3 x 18

650

377

561

75

58

CE 80/4 SB

95

80

200

315

838

113

360

3 x 18

650

377

725

107

60

Electric cable
(n.cond. x cable)
direct
Y/

n
(rpm)

3x400/
F2607KKK-B CD 80/2 SB 9,00 6,50
690

16,0

2900

4x4+

2x4x2,5+

F2615KKK-B CE 80/2 SB 25 18,50 3x400/


690

35,0

2900 4x10+

2x4x2,5+

F2611KKK-B CD 80/4 SB 1,50 1,10 3x400

2,4

1450 4x1,5+

F2613KKK-B CE 80/4 SB 3,00 2,20 3x400

5,3

1450 4x2,5+

MODEL

Power supply cable for control signals 2x1,5 mm2

142

l/1'
m3/h

500 1000 1500 2000 2500 3500

30

60

90

120 150 210

35,6 30,5 22,0 13,2 6,5

Discharge Head
in meters

Mot. Pow. VOLTAGE


(V)
HP kW

Amp.
3x400 V

CODE

47,0 40,0 31,5 27,0 21,5 16,0 6,4

8,5 5,2

11,5

8,3

1,5

5,4 2,8

PRICE

VITEX CD-CE

143

SUMP SEWAGE AND EFFLUENT PUMPS

MODEL

WEIGHT
(kg)

Free Bore

(mm.)

OVERALL DIMENSIONS (mm)


A

B2

K1

P2

Q (nx)

DE 100/2 SB

100

100

224

370

1021

117

435

3 x 18

650

433

904

258

75

DE 100/4 SB

100

100

224

370

892

117

435

3 x 18

650

433

775

129

75

DG 100/4 SB

100

100

224

370

892

117

435

3 x 18

650

433

775

144

78

MODEL

Mot. Pow. VOLTAGE


(V)
HP kW

Electric cable
(n.cond. x cable)
direct
Y/

Amp.
3x400 V

n
(rpm)

3x400/
690

40,0

2900

F2621KKK-B DE 100/4 SB 4,00 3,00 3x400

6,0

1450 4x2,5+

F2631KKK-B DG 100/4 SB 5,50 4,00 3x400

8,0

1450 4x2,5+

F2623KKK-B DE 100/2 SB 27,50 20

4x10+

Power supply cable for control signals 2x1,5 mm2

144

l/1' 0
m3/h 0

2x4x6+

500 1000 1500 2000 2500 5000


30

60

90

120 150 300

50,0 47,0 42,5 37,0 32,0 26,0

Discharge Head
in meters

CODE

12,8 11,2

8,2

16,8 15,6 10,4

6,0 4,3

2,4

7,8

3,0

5,2

8,0

PRICE

VITEX DE-DG

145

SUMP SEWAGE AND EFFLUENT PUMPS

MODEL

OVERALL DIMENSIONS (mm)

WEIGHT
(kg)

Free Bore

(mm.)

B2

K1

P2

Q (nx)

EF 125/4 SB

150

125

250

490

1039

172

570

3 x 18

750

585

867

210

73

EM 125/4 SB

150

125

250

490

1172

172

570

3 x 18

750

585

1000

300

95

EP 125/4 SB

150

125

250

490

1172

172

570

3 x 18

750

585

1000

320

93

MODEL

Mot. Pow. VOLTAGE


(V)
HP kW

Amp.
3x400 V

n
(rpm)

Electric cable
(n.cond. x cable)
direct
Y/

EF 125/4 SB 7,50 5,50

3x400/
690

11,5

1450

4x4+

2x4x2,5+

F2647KKK-B EM 125/4 SB 10,00 7,50

3x400/
690

17,5

1450

4x4+

2x4x2,5+

F2651KKK-B

3x400/
690

25,0

1450

4x6+

2x4x4+

F2641KKK-B

EP 125/4 SB 15,00 11,00

Power supply cable for control signals 2x1,5 mm2

146

l/1'
m3/h

0
0

1000 2000 3000 4000 5000 6000


60

16,4 12,0

Discharge Head
in meters

CODE

120 180 240 300 360

9,0

4,4

20,3 17,5 14,2 11,0

7,5 4,0

23,7 21,3 18,0 14,0 10,5 7,8

4,8

PRICE

VITEX EF-EM-EP

147

SUMP SEWAGE AND EFFLUENT PUMPS


VITEX SP SUBMERSIBLE PUMPS FOR
DENSE LIQUIDS IN FIXED
INSTALLATIONS
Electric submersible pumps that, with their special screw
impeller, are the ideal solution in all those situations where
the pumped liquid contains suspended solids or fibrous
substances.
Design Features
- Pump casing in G20 (UNI 5007) cast iron
- Impeller in nodular cast iron - GS 400-12 (UNI 4544)
- X30 Cr13 chrome steel shaft
- Motor casing in G20 (UNI 5007) cast iron
- Double mechanical seal:
upper widia/widia (for all models)
lower widia/widia or ceramic/graphite
MIM ring (for AC-AD-CD only)
- Connections: threaded (models AC - AD 50)
flanged (DN 50 - DN 100)
- Versions for fixed installations (SP)
Motor
- Class F insulation
- Level of protection IP68
- Power supply voltage: three phase 3 x 230 - 400V 50Hz
single phase 1 x 230 V 50Hz (for models AC and AD only)
- Direction of rotation: clockwise (motor end view)
- 10 m electric cable (type H07 RN-F)
Usage Limitations
- Liquid temperature: 25C (max 45C for intermittent use)
- Max installation depth: 20 m
Applications
- Rain and sewage water in general
- Waste water (industrial or civil)
- Purification systems
- Tanneries and slaughterhouse waste
- Liquid slurry and digested sludge
- Wood pulps and cellulose
- Dense liquid pulps (food and pharmaceutical industries)
- Transport of fruit and vegetables in an aqueous medium
- Fish industry
- Beer and sugar making industries
- Textile industry

Screw impeller

149

VITEX SP

SUMP SEWAGE AND EFFLUENT PUMPS

OVERALL DIMENSIONS (mm)

MODEL
A

B1 B3 D

E E1 F1 F2 F3 F4

WEIGHT
(kg)

Free Bore

(mm.)

AC 55/2 SP

50 50 165 237 200 93 128 552 30011/4" 524 59 312 180 220 3 x 400 280 465
18

58

30

AD 55/2 SP

50 50 165 237 200 93 128 552 30011/4" 524 59 312 180 220 3 x 400 280 465
18

60

28

CODE

MODEL

Electric cable
Mot. Pow. VOLTAGE
l/1'
n
Amp.
(n.cond. x cable) Q
HP kW (V)
1x230 V 3x400 V (rpm) direct
m3/h
Y/

1x230

F2576KKK

AC 55/2 SP 1,00 0,75 3x230

F2577KKK

3x400

F2585KKK

1x230

F2586KKK

AD 55/2 SP 1,50 1,10 3x230

F2587KKK

3x400

5,2

2,3

2900 4x1,5+

5,5

2,5

2900 4x1,5+

50

100 200 300 400 450


6

12

18

24

27

7,5

5,2

2,9

1,8

14,0 13,4 12,4 9,8

6,4

3,4

2,2

11,2 10,5 9,6


Discharge Head
in meters

F2575KKK

*Note: the connecting foot is not included in the price, see page 158

Power supply cable for control signals 2 x 1,5 mm2

150

PRICE

VITEX AC-AD

151

SUMP SEWAGE AND EFFLUENT PUMPS

OVERALL DIMENSIONS (mm)

MODEL
A

B1 B3 D

E E1 F1 F2 F3 F4 H

K1 M

WEIGHT
(kg)

Free Bore

(mm.)

CD 80/4 SP

95 100 224 315 250100 160 704 415 11/2" 842 113 402 200 250 3 x 650 377 725
18

82

58

CE 80/4 SP

95 100 224 315 250100 160 704 415 11/2" 892 113 402 200 250 3 x 650 377 775
18

114

60

CODE

MODEL

Mot. Pow. VOLTAGE


(V)
HP kW

Amp.
3x400 V

Electric cable
l/1' 0
n
(n.cond. x cable) Q
(rpm) direct
m3/h 0
Y/

CD 80/4 SP 1,50 1,10 3x400

2,4

1450 4x1,5+

F2614KKK-B

CE 80/4 SP 3,00 2,20 3x400

5,3

1450 4x2,5+

15

8,5 7,2

30

45

60

75

90

5,2 3,4

1,5

8,3 6,7

5,4 3,9

2,8

Discharge Head
in meters

F2612KKK-B

250 500 750 1000 1250 1500

Power supply cable for control signals 2 x 1,5 mm2

11,5

9,8

*Note: connecting foot sold separately, see page 166

152

PRICE

VITEX CD-CE

153

SUMP SEWAGE AND EFFLUENT PUMPS

OVERALL DIMENSIONS (mm)

MODEL
A

B1 B3 D

E E1 F1 F2 F3 F4 H

Free Bore

(mm.)

WEIGHT
(kg)

DE 100/4 SP

100 100 224 370 250 100 160 760 415 11/2" 857 82 458 200 250 3 x 650 433 775
18

154

75

DG 100/4 SP

100 100 224 370 250 100 160 760 415 11/2" 857 82 458 200 250 3 x 650 433 775
18

169

78

CODE

MODEL

Mot. Pow. VOLTAGE


(V)
HP kW

Amp.
3x400 V

n
(rpm)

Electric cable
(n.cond. x cable)
direct
Y/

6,0

1450 4x2,5+

F2632KKK-B DG 100/4 SP 5,50 4,00 3x400

8,0

1450 4x2,5+

l/1' 0
m3/h 0

500 1000 1500 2000 2500


30

12,8 11,2

60

90

120 150

8,2

6,0 4,3

2,4

7,8

3,0

Discharge Head
in meters

F2622KKK-B DE 100/4 SP 4,00 3,00 3x400

Power supply cable for control signals 2 x 1,5 mm2

16,8 15,6 10,4

* Note: connecting foot sold separately, see page 166


154

5,2

PRICE

VITEX DE-DG

155

SUMP SEWAGE AND EFFLUENT PUMPS

OVERALL DIMENSIONS (mm)

MODEL
A B1 B3 D

E E1 F1 F2 F3 F4

Free Bore

(mm.)

WEIGHT
(kg)

EF 125/4 SP

150 125 250 490 250 105 175 945 550 11/2" 949 82 610 200 250 3 x 750 585
18

867

245

73

EM 125/4 SP

150 125 250 490 250 105 175 945 550 11/2"1082 82 610 200 250 3 x 750 585 1000
18

335

95

EP 125/4 SP

150 125 250 490 250 105 175 945 550 11/2"1082 82 610 200 250 3 x 750 585 1000
18

355

93

n
(rpm)

Electric cable
(n.cond. x cable)
direct
Y/

3x400/
690

11,5

1450

4x4+

2x4x2,5+

F2648KKK-B EM 125/4 SP 10,00 7,50 3x400/


690

17,5

1450

4x4+

2x4x2,5+

EP 125/4 SP 15,00 11,00 3x400/


690

25,0

1450

4x6+

2x4x4+

F2642KKK-B

F2652KKK-B

MODEL

Mot. Pow. VOLTAGE


(V)
HP kW

EF 125/4 SP 7,50 5,50

Power supply cable for control signals 2 x 1,5 mm2

0
0

1000 2000 3000 4000 5000 6000


60

16,4 12,0

120 180 240 300 360

9,0

4,4

20,3 17,5 14,2 11,0

7,5 4,0

23,7 21,3 18,0 14,0 10,5 7,8

*
156

l/1'
m3/h

Discharge Head
in meters

Amp.
3x400 V

CODE

4,8

Note: connecting foot sold separately, see page 166

PRICE

VITEX EF-EM-EP

157

SUMP SEWAGE AND EFFLUENT PUMPS


VITEX OM HORIZONTAL PUMPS FOR
DENSE LIQUIDS
Horizontal electric surface pumps that, with their special
screw impeller, are the ideal solution in all those situations
where the pumped liquid contains suspended solids or
fibrous substances.
Design Features
- Pump casing in G20 (UNI 5007) cast iron
- Impeller in nodular cast iron GS 400-12 (UNI 4544)
- X30 Cr13 chrome steel shaft
- Mechanical seal: for models AC-AD
Pump end
widia/widia
Motor end
MIM ring
Adjustable packing for models CD-CE-DE-DG
- Connections: threaded (models AC - AD 50)
flanged (DN 50 - DN 100)
Motor
- Class F insulation
- Level of protection IP54
- Power supply voltage:
three phase 3 x 230 V - 400V - 690V 50Hz
single phase 1 x 230 V 50Hz
(for models AC and AD only)
Usage Limitations
- Liquid temperature: 25C
(max 45C for intermittent use)
Applications
- Rain water and sewage in general
- Waste water (industrial or civil)
- Purification systems
- Tanneries and slaughterhouse waste
- Liquid slurry and digested sludge
- Wood pulps and cellulose
- Dense liquid pulps (food and pharmaceutical industries)
- Transport of fruit and vegetables in an aqueous medium
- Fish industry
- Beer and sugar making industries
- Textile industry

Screw impeller

159

VITEX OM

SUMP SEWAGE AND EFFLUENT PUMPS

A1

A2

Free Bore

(mm.)

AC 50/2 OM - TM

472

360

83

2"

2"

180

40

110

20

295

270

300

11

30

AD 50/2 OM - TM

472

360

83

2"

2"

180

40

110

20

295

270

300

11

28

AC 55/2 OM - TM

499

360

100

50

50

180

40

160

20

295

270

300

11

30

AD 55/2 OM - TM

499

360

100

50

50

180

40

160

20

295

270

300

11

28

OVERALL DIMENSIONS (mm)

MODEL

MODEL

Mot. Pow.
HP kW

F2662KKK

VOLTAGE
(V)

n
(rpm)

l/1'
m3/h

50

100 200 300 400 450


6

12

18

24

27

1x230
AC 50/2 OM - TM 1,00 0,75

F2663KKK

4,85

1,75

2900

11,2 10,5

9,6 7,5

5,2

2,9

1,8

5,5

2,5

2900

14,0 13,4 12,4 9,8

6,4

3,4

2,2

5,2

2,3

2900

11,2 10,5

9,6 7,5

5,2

2,9

1,8

5,5

2,5

2900

14,0 13,4 12,4 9,8

6,4

3,4

2,2

3x400

F2660KKK

1x230
AD 50/2 OM - TM 1,50 1,10

F2661KKK

3x400

F2664KKK

1x230
AC 55/2 OM - TM 1,00 0,75

F2665KKK

3x400

F2666KKK

1x230
AD 55/2 OM - TM 1,50 1,10

F2667KKK

Amp.
1x230 V
3x400 V

Discharge Head
in meters

CODE

3x400

160

PRICE

VITEX AC-AD

161

SUMP SEWAGE AND EFFLUENT PUMPS

A1

A2

Free Bore

(mm.)

CD 80/4 OM - TB

650

500

106

80

100

233

60

217

25

450

395

430

14

58

CE 80/4 OM - TB

688

500

106

80

100

233

60

217

25

450

395

430

14

60

OVERALL DIMENSIONS (mm)

MODEL

CODE

MODEL

Mot. Pow.
HP kW

VOLTAGE
(V)

Amp.
3x400 V

n
(rpm)

CD 80/4 OM - TB

1,50 1,10

3x400

2,8

1450

F2672KKK

CE 80/4 OM - TB

3,00 2,20

3x400

5,5

1450

l/1' 0
m3/h 0

250 500 750 1000 1250 1500


15

30

45

60

8,5 7,5

5,2

3,4 1,5

11,5 9,8

8,3

6,7 5,4

75

90

Discharge Head
in meters

F2670KKK

162

3,9 2,8

PRICE

VITEX CD-CE

163

SUMP SEWAGE AND EFFLUENT PUMPS

A1

A2

Free Bore

(mm.)

DE 100/4 OM - TB

760

500

130

100

100

270

60

250

25

450

395

430

14

75

DG 100/4 OM - TB

760

500

130

100

100

270

60

250

25

450

395

430

14

78

OVERALL DIMENSIONS (mm)

MODEL

Mot. Pow.
HP kW

Amp.
3x400 V

n
(rpm)

F2680KKK DE 100/4 OM - TB 4,00 3,00

3x400

6,80

1450

F2681KKK

3x400
8,85

1450

MODEL

DG 100/4 OM - TB 5,50 4,00


F2682KKK

l/1'
m3/h

500 1000 1500 2000 2500

30

60

90

120 150

12,8 11,2 8,2

6,0

4,3

2,4

16,8 15,6 10,4 7,8

5,2

3,0

Discharge Head
in meters

VOLTAGE
(V)

CODE

3x690

164

PRICE

VITEX DE-DG

165

ACCESSORIES - FLANGES / COUPLING FEET / LIFTING CHAINS


CODE

PUMPS

DESCRIPTION

B7091KKK

AC 55/2 SB
AD 55/2 SB

PN 16 2 threaded flange kit

B7090KKK

AC 55/2 SP
AD 55/2 SP

PN 16 DN 50 flange (welded) kit

B7053KKK

CD 80/2 SB
CE 80/2 SB

PN 10 3 threaded flange kit

B7083KKK

CD 80/4 SB
CE 80/4 SB

PN 10 DN 80 flange (welded) kit

B7084KKK

CD 80/4 SP
CE 80/4 SP

PN 16 DN 100 flange (welded) kit

B7084KKK

DE 100/2 SB
DE 100/4 SB
DG 100/4 SB
DE 100/4 SP
DG 100/4 SP

PN 16 DN 100 flange (welded) kit

B7088KKK

EF 125/4 SB
EM 125/4 SB
EP 125/4 SB
EF 125/4 SP
EM 125/4 SP
EP 125/4 SP

PN 16 DN 125 flange (welded) kit

B7091KKK
B7090KKK

AC 55/2 OM-TM
AD 55/2 OM-TM

PN 16 2 flange pair (complete with bolts and gaskets)


PN 16 DN 50 flange pair (complete with bolts and gaskets)

B7053KKK
B7083KKK

CD 80/4 OM-TB
CE 80/4 OM-TB

PN 10 3 flange pair (complete with bolts and gaskets)


PN 10 DN 80 flange pair (complete with bolts and gaskets)

B7084KKK

DE 100/4 OM-TB
DG 100/4 OM-TB

PN 16 DN 100 flange pair (complete with bolts and gaskets)

CODE

PUMPS

DESCRIPTION

A2-A0114

AC 55/2 SP
AD 55/2 SP

DN 50 complete coupling foot

A2-A0100

CD 80/4 SP
CE 80/4 SP
DE 100/4 SP
DG 100/4 SP

DN 100 complete coupling foot

A2-A0110

EF 125/4 SP
EM 125/4 SP
EP 125/4 SP

DN 125 complete coupling foot

CODE

PUMPS

DESCRIPTION

F2706KKK

AC 50/2 SB
AD 50/2 SB
AC 55/2 SB/SP
AD 55/2 SB/SP
CD 80/4 SB/SP
CE 80/4 SB/SP

D 6 - ZN (10m) Galvanized steel lifting chain with Eyebolt

F2708KKK

CD 80/2 SB
DE 100/4 SB/SP
DG 100/4 SB/SP

D 8 - ZN (10m) Galvanized steel lifting chain with Eyebolt

F2710KKK

EF 125/4 SB/SP
EM 125/4 SB/SP
EP 125/4 SB/SP

D 8 - ZN (10m) Galvanized steel lifting chain with Eyebolt

166

VITEX
PRICE

PRICE

PRICE

SUBMERSIBLE PUMPS FOR OPEN AND DRILLED WELLS

50 Hz

PRATIKA

SUBMERSIBLE PUMPS
MULTISTAGE CENTRIFUGAL
SUBMERSIBLE PUMPS FOR CLEAR WATER
The PRATIKA submersible pumps are portable and
ready for use for installation in traditional wells, water
deposits, collection tanks, clear watercourses, lakes
etc.
Design Features
- Stainless steel pump casing
- Suction grid and base in stainless steel
- 15m H07 RN-F power supply cable with plug
- Graphite mechanical seal, ceramic counterface and
NBR 70 rubber lip seal ring
- Oil chamber for seal lubrication
- Stainless steel shaft steel with ceramic facing at the
points of seal wear
- Equipped with 32 mm rubber holder fitting
- Automatic version equipped with float switch
Motor
- Dry motor
- Level of protection IP 68
- Class F insulation
- Single phase supply with capacitor permanently
activated
- Thermal protection built into the motor winding
- Completely insulated cable connection chamber
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
- Suitable for continuous use

50
40

PR
AT
IKA

30

Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 40 C
- Maximum submersion under the water level 10 m

20
10

Applications
- Pumping of water from traditional wells
- Domestic tank installations for boosting domestic
drinking water systems
- Small-scale automatic systems for garden irrigation
- Surface irrigation

Hm

10
0,6

30
1,8

70
4,2

50
3

90
5,4

110
6,6

DNM

L / 1'
m3/ h

Dimensions mm.

Model

CODE

MODEL

Free Bore

DNM

Kg

406

162

178

1,5

1 1/4"

Nominal
Power

Absorbed
Power

HP

kW

HP

kW

L/1'

VOLTAGE

Amp.

F.

N3051010-B

PRATIKA

1,1

0,8

1,6

1,2

1 ~ 230 V

16

N3051000-B

PRATIKA - AUT

1,1

0,8

1,6

1,2

1 ~ 230 V

16

168

20

40

60

80

100

1,2

2,4

3,6

4,8

46

39

31

23

12

46

39

31

23

12

Q
3

m /h
Discharge Head
in meters

PRATIKA

Weight

PRICE

DOMINATOR 4

SUBMERSIBLE PUMPS
4 SUBMERSIBLE MULTISTAGE
CENTRIFUGAL PUMP FOR CLEAN
WATER

Motor
Dry motor with stainless steel casing cooled
by the pumped liquid.
Level of protection IP 68.
Class F insulation.
Single phase supply with capacitor
permanently activated.
Thermal protection built into the motor
winding.
Completely insulated cable connection
chamber.
Self-lubricating ball bearings.
Speed of rotation 2850 rpm.
Suitable for continuous use.

The DOMINATOR 4 submersible pumps are


suitable for istallation in traditional wells, water
deposits, collection tanks, clear watercourses,
lakes etc.
Design Features
Acetal resin impellers.
Polycarbonate diffusers with ceramic insert
at the point of wear.
Polycarbonate diffuser caps with stainless
steel inserts.
Thrust bearing ring inserted in every stage.
Noryl discharge head with 1 1/4" threaded
stainless.
steel insert.
Noryl base.
Stainless steel suction screen.
Stainless steel pump casing.
Integrated no-return valve.
Graphite mechanical seal, aluminium oxide
counterface.
Oil chamber for seal lubrication.
Shaft in AISI 303 steel with ceramic facing at
the points of wear.
20 m H07 RN-F power supply cable with plug.
20 m Nylon suspension cord.

Usage Limitations
Type of liquid: clean water with no suspended
solids or abrasive material.
Maximum liquid temperature 40C.
Maximum submersion under the water level
20 m.
Applications
Pumping of water from traditional wells.
Domestic tank installations for boosting
domestic drinking water systems.
Small-scale automatic systems for garden
irrigation.
Surface irrigation.

60
50

11
75 5/57
/5
6

40

5
50
5/

30
20
10
Hm

L / 1'
m3/ h

10
0,6

20
1,2

30
1,8

40
2,4

60
3,6

50
3,0

70
4,2

90 100
5,4 6,0

80
4,8

Dimensions

Model

Weight

Free Bore

DNM

Kg.

DOMINATOR 4 - 55/50

549

98

2 mm

1 1/4"

8,8

DOMINATOR 4 - 75/56

643

98

2 mm

1 1/4"

9,6

DOMINATOR 4 - 115/57

643

98

2 mm

1 1/4"

9,9

MODEL

Nominal
Power

Absorbed
Power

HP

kW

HP

kW

VOLTAGE

Amp.

F.

Stages

N3200020

DOMINATOR 4 - 55/50 M

0,70

0,50

0,90

0,65

1 ~ 220 240 V

16

N3200010

DOMINATOR 4 - 75/56 M

0,80

0,60

0,75

1 ~ 220 240 V

3,3

16

N3200040

DOMINATOR 4 - 115/57 M

0,80

1,50

1,10

1 ~ 220 240 V

16

169

L/1'
Q
m3/h

Dicharge Head
in meters

CODE

20

40

60

80

1.2

2.4

3.6

4.8

50

38,7

17

56

49,8

38,1

19

57

52

44,4

31,5

16,6

PRICE

DOMINATOR 5

SUBMERSIBLE PUMPS
SUBMERSIBLE MULTISTAGE
CENTRIFUGAL PUMP
FOR CLEAR WATER
The DOMINATOR 5" submersible pumps are
suitable for installation in traditional wells, water
deposits, collection tanks, clear watercourses,
lakes etc.
Design Features
- Impellers and diffusors in AISI 304 stainless
steel
- Stainless steel pump casing
- Suction grid and base in stainless steel
- Graphite mechanical seal, aluminium oxide
counterface
- Oil chamber for seal lubrication
- Shaft in AISI 304 steel with ceramic facing at
the points of wear
- 20 m H07 RN-F power supply cable with plug
- Built in capacitor
- Automatic version equipped with float switch

Motor
- Dry motor with stainless steel casing cooled
by the pumped liquid
- Level of protection IP 68
- Class F insulation
- Single phase supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Completely insulated cable connection
chamber
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 40 C
- Maximum submersion under the water level
20 m
Applications
- Pumping of water from traditional wells
- Domestic tank installations for boosting
domestic drinking water systems
- Small-scale automatic systems for garden
irrigation
- Surface irrigation

70
60
50
40

/50

75
70/

70

30

40

60

20

140
/65
140
/45

10
Hm
Q

L / 1'
m3/ h

20
2

100
6

80
4

120

160

140
8

Dimensions mm.

Model
A

Weight

Free Bore

DNM

Kg

DOMINATOR 5 - 70/50

470

132

2 mm

1 /4"

13.7

DOMINATOR 5 - 70/75

520

132

2 mm

1 1/4"

15.5

DOMINATOR 5 - 140/45

495

132

2 mm

1 1/4"

14.2

DOMINATOR 5 - 140/65

550

132

2 mm

1 1/4"

15.8

MODEL

N3191000
N3191010
N3191080

D 5 - 70/50
D 5 - 70/50 AUT
D 5 - 70/50

N3191020
N3191030
N3191090
N3191040
N3191050
N3191100

D 5 - 70/75
D 5 - 70/75 AUT
D 5 - 70/75
D 5 - 140/45
D 5 - 140/45 AUT
D 5 - 140/45
D 5 - 140/65
D 5 - 140/65 AUT
D 5 - 140/65

N3191060
N3191070
N3191110

Nominal
Power

Absorbed
Power

L/1'

VOLTAGE

Amp.

F.

N Q
Stages m3/h

HP

kW

HP

kW

0.7

1.3

0.95

1 ~ 220 240 V
3 ~ 400 V

4.5
1.8

16

1.4

1.45

1 ~ 220 240 V
3 ~ 400 V

6.5
2.1

20

1.2

0.9

1.8

1.3

1 ~ 220 240 V
3 ~ 400 V

5.5
2

16

1.5

1.1

2.3

1.7

1 ~ 220 240 V

7.5

20

3 ~ 400 V

2.6

170

20

40

60

80

100

1.2

2.4

3.6

4.8

120 140

PRICE

50.6 42.5 29.3

Discharge Head
in meters

CODE

75

7.2

8.4

7.5

60.7 41.4 17.2

45.8 43.3 38.4 33.3

28

21.8 15.2

7.4

64.5 60.2 53.5

38

27.9 18.2

7.6

46

SCM 4 Plus

SUBMERSIBLE PUMPS
4" MULTISTAGE CENTRIFUGAL
SUBMERSIBLE PUMPS COMPLETE
WITH MOTOR
The SCM 4 PLUS submersible pumps consist of a multistage
pumping unit directly connected to a submersible motor.
Especially suitable for pumping from deep 4'' (100mm) wells.
Design Features
- Delivery connection point in microcast AISI 304 stainless steel
- Suction flange in microcast AISI 304 stainless steel
- Pump casing in AISI 304 stainless steel
- Non return valve in AISI 304 stainless steel
- Cable protection filter and trough in AISI 430 stainless steel
- Hexagonal shaft in AISI 303 stainless steel with ceramic facing
on the upper end
- Acetal resin impellers
- Polycarbonate diffusors with ceramic insert at the point of wear
- Polycarbonate diffusor cap with stainless steel insert
- Thrust ring inserted in every stage
- Molybdenum bisulphide polyamide self-lubricating delivery
bearing
Motor
- 4" submersible motor
- Special resin impregnated sealed stator
- Water-cooled thrust bearings and bushes
- Approx. 1.5 m extendible power supply cable
- Non-polluting water cooling
- 4" NEMA flange
- Level of protection IP 58
- Class B insulation
- Speed of rotation 2850 rpm
- Special mechanical seal with sand guard
- Pressure compensation diaphragm
- Supplied without capacitor (single phase version)
- Suitable for continuous use
- Electrical control panel on request
Usage Limitations
- Type of liquid: clean non-aggressive, non-explosive, free of solids
- Maximum liquid temperature 30 C
- Max. start-ups per hour 20
- Motor protection with thermal relay provided by the user
Applications
- Pumping of water from drilled wells
- Automatic systems for garden irrigation
- Surface irrigation for agricultural use
- Drinking water systems
- Pumping and supply of stored deposits or of booster autoclaves
for civil and industrial systems

172

SUBMERSIBLE PUMPS

Delivery connection point in


microcast AISI 304 stainless steel
with an internal tapered double
profile with a stainless steel non
return valve and a double slot for
safety cable.
BENEFITS:
It resets flow resistance offering
maximum rigidity and high
resistance to protect the pump
against water hammering.

Shaft guide bearing made with a


self-lubricating closed bush in
molybdenum bisulphide polyamide
and stainless steel shaft with
ceramic insert at the point of wear.
BENEFITS:
Increases the life of the pump protection against dry operation high resistance to wear caused by
sand.

Floating impeller with suction point


shim on stainless steel moulded
with a diffusor cover. Thrust bearing
inserted between the hub of the
impeller and diffusor formed by
one ceramic ring moulded with the
diffusor and a free ring in graphite.
"International Patent"
BENEFITS:
This extraordinary technological
innovation leads to a large increase
in efficiency as well as high
resistance to abrasion by sand and
to dry operation.

173

Motor bracket and suction point


in microcast AISI 304 stainless
steel rigidly welded to the outer
stainless steel liner. Stainless steel
suction grid.
BENEFITS:
This system offers high resistance
to mechanical stresses caused by
operating pressure.
Maximum rigidity of the whole
structure eliminates vibrations.

SCM 4 Plus
TABLE FOR CALCULATING PUMP LENGTH
A
Total length
mm.

B
Motor length
mm.

C
Pump length
mm.

SCM 4 PLUS 40/57 M


SCM 4 PLUS 40/57 T
SCM 4 PLUS 40/90 M
SCM 4 PLUS 40/90 T
SCM 4 PLUS 40/120 M
SCM 4 PLUS 40/120 T
SCM 4 PLUS 40/185 M
SCM 4 PLUS 40/185 T
SCM 4 PLUS 40/240 M
SCM 4 PLUS 40/240 T

576
557
717
688
857
829
1109
1081
1339
1310

242
223
271
242
299
271
327
299
356
327

SCM 4 PLUS 55/50 M


SCM 4 PLUS 55/50 T
SCM 4 PLUS 55/80 M
SCM 4 PLUS 55/80 T
SCM 4 PLUS 55/105 M
SCM 4 PLUS 55/105 T
SCM 4 PLUS 55/160 M
SCM 4 PLUS 55/160 T
SCM 4 PLUS 55/200 M
SCM 4 PLUS 55/200 T
SCM 4 PLUS 55/300 T

509
490
628
599
700
672
862
834
1026
997
1317

SCM 4 PLUS 75/40 M


SCM 4 PLUS 75/40 T
SCM 4 PLUS 75/56 M
SCM 4 PLUS 75/56 T
SCM 4 PLUS 75/75 M
SCM 4 PLUS 75/75 T
SCM 4 PLUS 75/110 M
SCM 4 PLUS 75/110 T
SCM 4 PLUS 75/140 M
SCM 4 PLUS 75/140 T
SCM 4 PLUS 75/210 T

MODEL

L
Packing length

Total weight
Kg.

334
334
446
446
558
558
782
782
983
983

730
710
870
840
1010
980
1260
1230
1490
1460

11.8
10.8
14.0
12.7
16.1
14.9
19.2
17.9
22.2
20.8

242
223
271
242
299
271
327
299
356
327
356

267
267
357
357
401
401
535
535
670
670
961

660
640
780
750
850
830
1012
990
1180
1150
1470

11.3
10.3
13.1
11.8
14.9
13.7
17.3
16.0
19.8
18.4
22.3

545
526
631
602
744
716
915
887
1058
1029
1372

242
223
271
242
299
271
327
299
356
327
356

303
303
360
360
445
445
588
588
702
702
1016

700
680
780
750
900
870
1070
1040
1200
1180
1520

11.2
10.2
12.9
11.6
14.8
13.6
17.1
15.8
19.4
18.0
21.5

SCM 4 PLUS 115/30 M


SCM 4 PLUS 115/30 T
SCM 4 PLUS 115/50 M
SCM 4 PLUS 115/50 T
SCM 4 PLUS 115/65 M
SCM 4 PLUS 115/65 T
SCM 4 PLUS 115/95 M
SCM 4 PLUS 115/95 T
SCM 4 PLUS 115/122 M
SCM 4 PLUS 115/122 T
SCM 4 PLUS 115/185 T
SCM 4 PLUS 115/245 T

488
469
602
573
687
659
829
801
973
944
1202
1525

242
223
271
242
299
271
327
299
356
327
356
423

246
246
331
331
388
388
502
502
617
617
846
1102

640
620
750
720
840
810
980
950
1120
1100
1350
1680

11.0
10.0
12.8
11.5
14.4
13.2
16.6
15.3
18.8
17.4
20.8
25.0

SCM 4 PLUS 150/42 M


SCM 4 PLUS 150/42 T
SCM 4 PLUS 150/64 M
SCM 4 PLUS 150/64 T
SCM 4 PLUS 150/84 M
SCM 4 PLUS 150/84 T
SCM 4 PLUS 150/120 T
SCM 4 PLUS 150/170 T
SCM 4 PLUS 150/200 T
SCM 4 PLUS 150/300 T

652
624
790
762
929
900
1142
1466
1816
2407

299
271
327
299
356
327
356
423
590
704

353
353
463
463
573
573
786
1043
1226
1703

800
780
940
910
1080
1050
1300
1620
1970
2560

14.0
12.8
16.1
14.8
18.3
16.9
20.1
24.2
33.1
42.3

SCM 4 PLUS 250/53 M


SCM 4 PLUS 250/53 T
SCM 4 PLUS 250/78 T
SCM 4 PLUS 250/100 T
SCM 4 PLUS 250/127 T
SCM 4 PLUS 250/185 T

951
922
1186
1550
1833
2462

356
327
356
514
590
704

595
595
830
1036
1243
1758

1100
1070
1340
1700
1983
2612

18.0
15.6
18.0
23.9
29.6
42.6

DNM

96

2"

174

105

1 1/4"

DNM

SCM 4 Plus 40

SUBMERSIBLE PUMPS

The power curve refers to the brake horse power (BHP) per stage.

MODEL

N3181000

SCM 4 PLUS-40/57 M

N3181010

SCM 4 PLUS-40/57 T

N3181020

SCM 4 PLUS-40/90 M

N3181030

SCM 4 PLUS-40/90 T

N3181040

SCM 4 PLUS-40/120 M

14

19
N3181050

SCM 4 PLUS-40/120 T

N3181060

SCM 4 PLUS-40/185 M

N3181070

SCM 4 PLUS-40/185 T

N3181080

SCM 4 PLUS-40/240 M

29

38
N3181090

SCM 4 PLUS-40/240 T

Motor
Power

Stadi
Stages

HP

kW

0,5

0,37

0,75

1,5

0,55

L/1'

VOLTAGE

Amp.

1 ~ 230 V

3,2

3 ~ 400 V

1,1

1 ~ 230 V

4,3

3 ~ 400 V

1,6

1 ~ 230 V

5,3

3 ~ 400 V

2,1

1 ~ 230 V

7,8

3 ~ 400 V

3,2

1 ~ 230 V

9,9

3 ~ 400 V

F Q

16

20

30

0,75
40

1,1

1,5

175

m3/h

Discharge Head
in meters

CODE

% indicates the pump hydraulic efficiency

10

20

30

40

DNM

0,6

1,2

1,8

2,4

49

41

26

76

64

40

104

86

55

158

130

85

10

205

160

110

12

50

11/4"

PRICE

SCM 4 Plus 55

SUBMERSIBLE PUMPS

The power curve refers to the brake horse power (BHP) per stage.

MODEL

Motor
Power

Stadi
Stages

HP

kW

L/1'

VOLTAGE

Amp.

F Q

N3182000
N3182010

SCM 4 PLUS-55/50 M
SCM 4 PLUS-55/50 T

0,5

0,37

1 ~ 230 V
3 ~ 400 V

3,2
1,1

16

N3182020
N3182030

SCM 4 PLUS-55/80 M
SCM 4 PLUS-55/80 T

10

0,75

0,55

1 ~ 230 V
3 ~ 400 V

4,3
1,6

20

N3182040
N3182050

SCM 4 PLUS-55/105 M
SCM 4 PLUS-55/105 T

12

0,75

1 ~ 230 V
3 ~ 400 V

5,3
2,1

30

N3182060
N3182070

SCM 4 PLUS-55/160 M
SCM 4 PLUS-55/160 T

18

1,5

1,1

1 ~ 230 V
3 ~ 400 V

7,8
3,2

40

N3182080
N3182090

SCM 4 PLUS-55/200 M
SCM 4 PLUS-55/200 T

24

1,5

1 ~ 230 V
3 ~ 400 V

9,9
4

50

N3182100

SCM 4 PLUS-55/300 T

37

2,2

3 ~ 400 V

5,9

176

m3/h

Discharge Head
in meters

CODE

% indicates the pump hydraulic efficiency

10

20

30

40

50

DNM

0,6

1,2

1,8

2,4

47

42

36

23

75

66

55

35

12

98

87

72

46

12

145

132

110

70

24

187

169

145

90

30

278

244

200

140

50

11/4"

PRICE

SCM 4 Plus 75

SUBMERSIBLE PUMPS

The power curve refers to the brake horse power (BHP) per stage.

MODEL

Motor
Power

Stadi
Stages

HP

kW

L/1'

VOLTAGE

Amp.

N3183000
N3183010

SCM 4 PLUS-75/40 M
SCM 4 PLUS-75/40 T

0,5

0,37

1 ~ 230 V
3 ~ 400 V

3,2
1,1

16

N3183020
N3183030

SCM 4 PLUS-75/56 M
SCM 4 PLUS-75/56 T

0,75

0,55

1 ~ 230 V
3 ~ 400 V

4,3
1,6

20

N3183040
N3183050

SCM 4 PLUS-75/75 M
SCM 4 PLUS-75/75 T

11

0,75

1 ~ 230 V
3 ~ 400 V

5,3
2,1

30

N3183060
N3183070

SCM 4 PLUS-75/110 M
SCM 4 PLUS-75/110 T

16

1,5

1,1

1 ~ 230 V
3 ~ 400 V

7,8
3,2

40

N3183080
N3183090

SCM 4 PLUS-75/140 M
SCM 4 PLUS-75/140 T

20

1,5

1 ~ 230 V
3 ~ 400 V

9,9
4

50

N3183100

SCM 4 PLUS-75/210 T

30

2,2

3 ~ 400 V

5,9

177

m3/h

Discharge Head
in meters

CODE

% indicates the pump hydraulic efficiency

20

30

40

50

60

DNM

1,2

1,8

2,4

3,6

36

33

28

23

15

50

45

40

32

21

67

62

55

45

30
11/4"

100

92

82

68

44

127

116

105

86

57

186

170

155

130

80

PRICE

SCM 4 Plus 115

SUBMERSIBLE PUMPS

The power curve refers to the brake horse power (BHP) per stage.

CODE

MODEL

Motor
Power

Stages
Stadi

VOLTAGE

HP

kW

% indicates the pump hydraulic efficiency

Amp.

F Q

L/1'

30

40

50

60

80

90

100

m3/h

1,8

2,4

3,6

4,8

5,4

DNM

26

24

22

20

13

6,4

46

43

40

36

23

16

10

58

55

51

46

29

20

11

83

80

74

67

43

30

18 11/4"

109 106

98

88

55

38

21

SCM 4 PLUS-115/30 M
SCM 4 PLUS-115/30 T

0,5

0,37

1 ~ 230 V
3 ~ 400 V

3,2
1,1

16

N3184020
N3184030

SCM 4 PLUS-115/50 M
SCM 4 PLUS-115/50 T

0,75

0,55

1 ~ 230 V
3 ~ 400 V

4,3
1,6

20

N3184040
N3184050

SCM 4 PLUS-115/65 M
SCM 4 PLUS-115/65 T

0,75

1 ~ 230 V
3 ~ 400 V

5,3
2,1

30

N3184060
N3184070

SCM 4 PLUS-115/95 M
SCM 4 PLUS-115/95 T

13

1,5

1,1

1 ~ 230 V
3 ~ 400 V

7,8
3,2

40

N3184080
N3184090

SCM 4 PLUS-115/122 M
SCM 4 PLUS-115/122 T

17

1,5

1 ~ 230 V
3 ~ 400 V

9,9
4

50

N3184100

SCM 4 PLUS-115/185 T

24

2,2

3 ~ 400 V

5,9

160 153 143 130

85

58

31

N3184110

SCM 4 PLUS-115/245 T

33

3 ~ 400 V

7,8

218 210 198 179 118

84

47

178

Discharge Head
in meters

N3184000
N3184010

PRICE

SCM 4 Plus 150

SUBMERSIBLE PUMPS

CODE

MODEL

Motor
Power

Stages

VOLTAGE

HP

kW

Amp.

% indicates the pump hydraulic efficiency

F Q

N3185000
N3185010

SCM 4 PLUS-150/42 M
SCM 4 PLUS-150/42 T

0,75

1 ~ 230 V
3 ~ 400 V

5,3
2,1

30

N3185020
N3185030

SCM 4 PLUS-150/64 M
SCM 4 PLUS-150/64 T

1,5

1,1

1 ~ 230 V
3 ~ 400 V

7,8
3,2

40

N3185040
N3185050

SCM 4 PLUS-150/84 M
SCM 4 PLUS-150/84 T

12

1,5

1 ~ 230 V
3 ~ 400 V

9,9
4

50

N3185060

SCM 4 PLUS-150/120 T

17

2,2

3 ~ 400 V

5,9

N3185070

SCM 4 PLUS-150/170 T

24

3 ~ 400 V

7,8

N3185080

SCM 4 PLUS-150/200 T

29

5,5

3 ~ 400 V

10

N3185090

SCM 4 PLUS-150/300 T

42

7,5

5,5

3 ~ 400 V

13,7

179

L/1'

40

50

60

80

m3/h

2,4

3,6

4,8

7,2

8,4 DNM

38

37

36

33

26

17

10

59

58

57

50

39

27

15

80

78

75

64

50

34

20

116 113 108

96

77

53

26

160 157 152 134 106

69

30

191 188 179 152 112

71

32

292 290 285 252 210 155

82

Discharge Head
in meters

The power curve refers to the brake horse power (BHP) per stage.

100 120 140

2"

PRICE

SCM 4 Plus 250

SUBMERSIBLE PUMPS

The power curve refers to the brake horse power (BHP) per stage.

MODEL

Motor
Power

Stadi
Stages

L/1'

VOLTAGE

HP

kW

1,5

N3186000

SCM 4 PLUS-250/53 M

N3186010

SCM 4 PLUS-250/53 T

N3186020

SCM 4 PLUS-250/78 T

13

N3186030

SCM 4 PLUS-250/100 T

17

N3186040

SCM 4 PLUS-250/127 T

N3186050

SCM 4 PLUS-250/185 T

Amp.

1 ~ 230 V

9,9

3 ~ 400 V

2,2

3 ~ 400 V

5,9

3 ~ 400 V

7,8

21

5,5

3 ~ 400 V

10

31

7,5

5,5

3 ~ 400 V

13,7

180

F Q

m3/h

50

Discharge Head
in meters

CODE

% indicates the pump hydraulic efficiency

100 120 140 180 200 220 240

7,2

8,4 10,8 12 13,2 14,4 DNM

43

41

37

26

18

11

63

59

54

41

30

18

83

78

66

54

41

24

106 100

90

68

49

31

14

152 141 127

81

57

36

18

2"

PRICE

SCM 4 Plus

SUBMERSIBLE PUMPS
PUMP-ENDS
10

20

30

40

NECESSARY
MOTOR

SCM 4 PLUS 40/57

49

41

37

26

HP 0,5

N1050020

SCM 4 PLUS 40/90

76

64

40

HP 0,75

N1050030

SCM 4 PLUS 40/120

104

86

55

HP 1

N1050040

SCM 4 PLUS 40/185

85

10

HP 1,5

N1050050

SCM 4 PLUS 40/240

205 160 110

12

HP 2

CODE

MODEL

10

20

30

40

50

NECESSARY
MOTOR

N1050060

SCM 4 PLUS 55/50

47

42

36

23

HP 0,5

N1050070

SCM 4 PLUS 55/80

75

66

55

35

12

HP 0,75

N1050080

SCM 4 PLUS 55/105

98

87

72

46

15

HP 1

N1050090

SCM 4 PLUS 55/160

145 132 110

70

24

HP 1,5

N1050100

SCM 4 PLUS 55/200

187 169 145

90

30

HP 2

N1050110

SCM 4 PLUS 55/300

278 244 200 140

50

HP 3

CODE

MODEL

20

30

40

50

60

NECESSARY
MOTOR

N1050120

SCM 4 PLUS 75/40

36

33

28

23

15

HP 0,5

N1050130

SCM 4 PLUS 75/56

50

45

40

32

21

HP 0,75

N1050140

SCM 4 PLUS 75/75

67

62

55

45

30

HP 1

N1050150

SCM 4 PLUS 75/110

100

92

82

68

44

HP 1,5

N1050160

SCM 4 PLUS 75/140

127 116 105

86

57

HP 2

N1050170

SCM 4 PLUS 75/210

186 170 155 130

80

HP 3

Discharge Head in meters

N1050010

Ql/1'

Ql/1'

Discharge Head in meters

MODEL

Ql/1'

181

Discharge Head in meters

CODE

158 130

PRICE

PRICE

PRICE

SCM 4 Plus
PUMP-ENDS
30

40

50

60

80

90

100

NECESSARY
MOTOR

SCM 4 PLUS 115/30

26

24

22

20

13

6,4

HP 0,5

N1050190

SCM 4 PLUS 115/50

46

43

40

36

23

16

10

HP 0,75

N1050200

SCM 4 PLUS 115/65

58

55

51

46

29

20

11

HP 1

N1050210

SCM 4 PLUS 115/95

83

80

74

67

43

30

18

HP 1,5

N1050220

SCM 4 PLUS 115/122

98

88

55

38

21

HP 2

N1050230

SCM 4 PLUS 115/185

160 153 143 130

85

58

31

HP 3

N1050240

SCM 4 PLUS 115/245

218 210 198 179 118

84

47

HP 4

MODEL

N1050180

CODE

MODEL

N1050250

Ql/1'

Discharge Head in meters

CODE

Ql/1'

109 106

NECESSARY
MOTOR

50

60

80 100 120 140

SCM 4 PLUS 150/42

38

37

36

33

26

17

10

HP 1

N1050260

SCM 4 PLUS 150/64

59

58

57

50

39

27

15

HP 1,5

N1050270

SCM 4 PLUS 150/84

80

78

75

64

50

34

20

HP 2

N1050280

SCM 4 PLUS 150/120

96

77

53

26

HP 3

N1050290

SCM 4 PLUS 150/170

160 157 152 134 106

69

30

HP 4

N1050300

SCM 4 PLUS 150/200

191 188 179 152 112

71

32

HP 5,5

N1050310

SCM 4 PLUS 150/300

292 290 285 252 210 255

82

HP 7,5

Discharge Head in meters

40

116 113 118

NECESSARY
MOTOR

CODE

MODEL

N1050320

SCM 4 PLUS 250/53

43

41

37

26

18

11

HP 2

N1050330

SCM 4 PLUS 250/78

63

59

54

41

30

18

HP 3

N1050340

SCM 4 PLUS 250/100

83

78

66

54

41

24

HP 4

N1050350

SCM 4 PLUS 250/127

90

68

49

31

14

HP 5,5

N1050360

SCM 4 PLUS 250/185

81

57

36

18

HP 7,5

182

Discharge Head in meters

Ql/1' 100 120 140 180 200 220 240

106 100

152 141 127

PRICE

PRICE

PRICE

SUBMERSIBLE PUMPS
4 SUBMERSIBLE MOTORS FOR SCM 4 PLUS
NEMA SPEC WITH PART ELECTRICAL CABLE
POWER
HP
kW

VOLTAGE

Hz

222P0390

0,5

0,37

1 ~ 230V

50

221P0740

0,5

0,37

3 ~ 400V

50

222P0400

0,75

0,55

1 ~ 230V

50

221P0740

0,75

0,55

3 ~ 400V

50

222P0310

0,74

1 ~ 230V

50

221P0760

0,74

3 ~ 400V

50

222P0320

1,5

1,1

1 ~ 230V

50

221P0770

1,5

1,1

3 ~ 400V

50

222P0330

1,5

1 ~ 230V

50

221P0570

1,5

3 ~ 400V

50

221P0580

2,2

3 ~ 400V

50

221P0590

3 ~ 400V

50

221P0600

5,5

3 ~ 400V

50

221P0610

7,5

5,5

3 ~ 400V

50

POWER
HP
kW

VOLTAGE

Hz

222P0010

0,5

0,37

1 ~ 230V

50

221P0030

0,5

0,37

3 ~ 400V

50

222P0020

0,75

0,55

1 ~ 230V

50

221P0040

0,75

0,55

3 ~ 400V

50

222P0030

0,74

1 ~ 230V

50

221P0050

0,74

3 ~ 400V

50

222P0040

1,5

1,1

1 ~ 230V

50

221P0060

1,5

1,1

3 ~ 400V

50

222P0050

1,5

1 ~ 230V

50

221P0070

1,5

3 ~ 400V

50

221P0080

2,2

3 ~ 400V

50

221P0090

3 ~ 400V

50

221P0100

5,5

3 ~ 400V

50

CODE

PRICE

WATER COOLED

CODE

OIL COOLED

183

PRICE

SA

SUBMERSIBLE PUMPS
6" MULTISTAGE SUBMERSIBLE PUMPS
COMPLETE WITH MOTOR
The SA submerged pumps consist of a multistage pumping unit
directly connected to a submersible motor. Especially suitable for
pumping from deep 6'' (150mm) wells.
Design Features
- Delivery connection point in nodular cast iron
- Suction flange in nodular cast iron
- Stainless steel outer liner
- Built in non return valve
- Cable protection filter and trough, in stainless steel
- Stainless steel splined shaft
- Noryl or polycarbonate impellers:
SA 615/SA 625 with radial impellers,
SA630/SA 650 with semiaxial impellers
- Noryl diffusors
- Stainless steel wear rings
- Bronze/rubber bush bearings
Motor
- 6" Franklin submersible motor
- Special resin impregnated sealed stator
- Water-cooled thrust bearings and bushes
- Approx. 1.5 m extendible power supply cable
- Non-polluting water cooling
- 6" NEMA flange
- Level of protection IP58. Class F insulation
- Speed of rotation 2850 rpm
- Special mechanical seal with sand guard
- Pressure compensation diaphragm
- Suitable for continuous use
- Electrical control panel on request
- Direction of rotation anticlockwise (seen from the delivery end)
Usage Limitations
- Type of liquid: clean non-aggressive, non-explosive, free of solids
- Maximum liquid temperature 30 C
- Max. start-ups per hour: 15
- Motor protection with thermal relay provided by the user
- Maximum quantity of sand present: 40 g/m3
Applications
- Civil and industrial supply systems
- Overhead or surface irrigation
- Boosting
- Firefighting
- Various civil and industrial applications
- Mains water supply systems

184

SA 615

SUBMERSIBLE PUMPS

145

L1

DNM 3 Gas

MOTOR

Model

Electric pump
Pump
casing Motor
L1
L
Weight

SA 615/4
SA 615/5
SA 615/6
SA 615/9
SA 615/12
SA 615/18

(mm)

(mm)

(mm)

(kg)

435
478
511
625
738
966

87
87
87
87
137
137

791
901
1056
1329
1384
1677

22
27
30
41
58
67
The power curve refers to the brake horse power (BHP) per stage.

CODE

MODEL

N of
Stages

Motor
Power

VOLTAGE

HP

kW

Amp.

% indicates the pump hydraulic efficiency

L/1'

120

160

200

230

260

300

m3/h

7,2

9,6

12

13,8

15,6

18

PRICE

SA 615/4*

2,2

3 ~ 400 V

5,5

62

60

55

51

46

39

31

D8761KKK

SA 615/5*

3 ~ 400 V

78

74

69

63

57

49

39

D8762KKK

SA 615/6*

4,0

3 ~ 400 V

10

94

89

82

75

68

58

46

D8763KKK

SA 615/9*

7,5

5,5

3 ~ 400 V

13

140

134

123

113

101

88

70

D8764KKK

SA 615/12

12

10

7,5

3 ~ 400 V

16

187

179

166

152

136

118

92

D8765KKK

SA 615/18

18

15

11

3 ~ 400 V

23

281

268

250

231

210

180

138

* WITH 4 MOTOR

185

Discharge Head
in meters

D8760KKK

SA 625

SUBMERSIBLE PUMPS

145

L1

DNM 3 Gas

MOTOR

Model

SA 625/4
SA 625/6
SA 625/8
SA 625/12
SA 625/16
SA 625/20

Electric pump
Pump
casing Motor
L1
L
Weight
(mm)

(mm)

(mm)

(kg)

511
625
738
966
1193
1474

87
87
137
137
137
137

1056
1329
1384
1677
1969
2316

30
41
57
66
75
86
The power curve refers to the brake horse power (BHP) per stage.

CODE

MODEL

N of
Stages

Motor
Power

VOLTAGE

HP

kW

Amp.

% indicates the pump hydraulic efficiency

L/1'

200

300

350

400

500

600

m3/h

12

18

21

24

30

36

PRICE

SA 625/4*

3 ~ 400 V

10

61

53

48

44

40

28

17

D8772KKK

SA 625/6*

7,5

5,5

3 ~ 400 V

12

91

80

71

66

59

43

25

D8773KKK

SA 625/8

10

7,5

3 ~ 400 V

16

122

106

95

87

79

58

34

D8774KKK

SA 625/12

12

15

11

3 ~ 400 V

23

182

159

143

131

119

88

50

D8775KKK

SA 625/16

16

20

15

3 ~ 400 V

31

243

212

190

177

159

118

67

D8776KKK

SA 625/20

20

25

18,5

3 ~ 400 V

38

304

265

238

220

198

146

84

* WITH 4 MOTOR

186

Discharge Head
in meters

D8771KKK

SA 630

SUBMERSIBLE PUMPS

145

L1

DNM 3 Gas

MOTOR

Model

SA 630/4
SA 630/5
SA 630/8
SA 630/10
SA 630/12

Electric pump
Pump
casing Motor
L1
L
Weight
(mm)

(mm)

(mm)

(kg)

522
582
762
882
1002

87
137
137
137
137

1226
1228
1473
1658
1844

39
54
62
70
78
The power curve refers to the brake horse power (BHP) per stage.

CODE

MODEL

N of
Stages

Motor
Power
HP

kW

VOLTAGE

Amp.

% indicates the pump hydraulic efficiency

L/1'

300

400

500

600

700

800

m3/h

18

24

30

36

42

48

PRICE

SA 630/4*

7,5

5,5

3 ~ 400 V

12

63

57

53

47

40

30

19

D8783KKK

SA 630/5

10

7,5

3 ~ 400 V

16

78

72

67

59

50

37

23

D8784KKK

SA 630/8

15

11

3 ~ 400 V

23

126

114

106

94

80

62

37

D8785KKK

SA 630/10

10

20

15

3 ~ 400 V

31

157

143

133

119

101

76

45

D8786KKK

SA 630/12

12

25

18,5

3 ~ 400 V

38

188

171

160

143

122

92

55

* WITH 4 MOTOR

187

Discharge Head
in meters

D8782KKK

SA 650

SUBMERSIBLE PUMPS

145

L1

DNM 3 Gas

MOTOR

Model

SA 650/4
SA 650/6
SA 650/9
SA 650/10
SA 650/12

Electric pump
Pump
casing Motor
L1
L
Weight
(mm)

(mm)

(mm)

(kg)

522
642
822
882
1002

137
137
137
137
137

1168
1353
1598
1724
1909

53
61
69
76
84
The power curve refers to the brake horse power (BHP) per stage.

CODE

MODEL

N of
Stages

Motor
Power
HP

kW

VOLTAGE

Amp.

% indicates the pump hydraulic efficiency

L/1'

600

700

800

900

1000

1100

m3/h

36

42

48

54

60

66

PRICE

SA 650/4

10

7,5

3 ~ 400 V

15

54

40

35

31

25

19

13

D8793KKK

SA 650/6

15

11

3 ~ 400 V

21

81

59

53

46

37

29

20

D8794KKK

SA 650/9

20

15

3 ~ 400 V

31

122

90

80

68

57

44

30

D8795KKK

SA 650/10

10

25

18,5

3 ~ 400 V

34

135

101

90

77

63

49

33

D8796KKK

SA 650/12

12

30

22

3 ~ 400 V

40

162

120

107

93

75

59

40

* WITH 4 MOTOR

188

Discharge Head
in meters

D8792KKK

SCM 4 Plus - SA 6

ACCESSORIES

SELECTION OF ELECTRIC CABLE FOR SUBMERSIBLE


PUMPS
MAXIMUM ELECTRIC CABLE LENGTH
Voltage loss 3% - Maximum environmental temperature +30%

Direct Starting

1 ~ 220 240 V - 50 Hz

3 ~ 400 V - 50 Hz

1 four-pole cable
4 x mm2
MOTOR

1 four-pole cable
4 x mm2
MOTOR

1.5 2.5 4

10

1.5 2.5 4

kW

Cables - L max in m.

kW

0.37

114 191 305

0.37

777

0.55

77 128 205 308

0.55

523

0.75

56 94 151 226 376

0.75

384

1.1

38 64 103 154 257

1.1

262

1.5

47 75 113 188

1.5

192 320

2.2

32 51 77 128

2.2

131 218 349

35 50 70

Cables - L max in m.

96 160 256 385

72 120 192 289

5.5

10 16 25

52

88 140 210 351

7.5

64 103 154 258

9.2

52

84

126 210 337

11

70

106 176 282

13

60

90

149 239 374

78

130 208 324

15
18.5

105 170 261 360 500

22

89 139 212 294 409

189

PUMPS FOR SPECIAL USES

50 Hz

P.G.A.

PUMPS FOR SPECIAL USES

PGA
DELTA OIL
SPECIAL SELF-PRIMING LIQUID RING PUMPS
FOR DIESEL TRANSFER
The PGA series pumps are particularly
suitable for diesel transfer.

30

10

O
IL

4 M DELIVERY KIT
PIPE AND GUN

0
-4

TA
EL
/D

20

Hm
Q

4 M SUCTION KIT

60
0

Applications
- Manufacture of delivery assemblies

Usage Limitations
- Type of liquid: diesel
- Maximum liquid temperature 50C
- Maximum recommended suction height
5m with foot valve
- Maximum operating pressure 6 bar

40

-3

- DELTA-OIL version
Handle, electric switch, power supply cable
with plug

Motor
- Enclosed, externally ventilated
- Level of protection IP55
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal
protection built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use

40

Design Features
- Cast iron pump casing
- Cast iron motor bracket
- Brass finned impeller
- Stainless steel shaft
- Mechanical graphite seal with ceramic
counterface
- Intermediate flange drainage pipe

50

L / 1'
m3/ h

15
0,9

30
1,8

45
2,7

75
4,5

VOLUMETRIC
LITRE-COUNTER
Dimensions mm.

Model
A

60
3,6

Weight
E

DNA

DNM

kg

141

255

20

120

119

3/4"

3/4"

6,2

PGA 60 - 40

148

260

24

120

123

1"

1"

DELTA OIL

141

255

20

120

119

3/4"

3/4"

CODE

MODEL

Nominal Absorbed
Power
Power

VOLTAGE

Amp.

F. Q

HP kW HP kW
N6232090
N6232100

PGA 40 - 30 M
PGA 40 - 30 T

0,6 0,45 0,75 0,55

1 ~ 220 240 V
3 ~ 230 400 V

2,7
1,6-0,9

N6232130
N6232140

PGA 60 - 40 M
PGA 60 - 40 T

0,8 0,6 1,2 0,9

1 ~ 220 240 V
3 ~ 230 400 V

4,5
2,7-1,6

12,5

N6232170

DELTA OIL

0,6 0,45 0,75 0,55

1 ~ 220 240 V

2,7

ACCESSORIES
ZA000840

4 M SUCTION KIT

ZA005380

4 M DELIVERY KIT PIPE AND GUN

ZA000120

VOLUMETRIC METER PLASTC CASE

ZA005160

VOLUMETRIC METER ALUMINIUM CASE

ZA000130

ALUMINIUM DELIVERY GUN WITH RUBBER HOLDER 19 mm

191

L/1'

10

15

25

35

45

60

m3/h

0,3

0,6

0,9

1,5

2,1

2,7

3,6

Discharge Head
in meters

PGA 40 - 30

28

23

18

13

39

34

32

25

18

12

28

23

18

13

PRICE

PUMPS FOR SPECIAL USES


SUBMERSIBLE PUMPS
FOR FOUNTAINS AND WATER FEATURES
The VERSAILLES pumps have been designed for
fountains, water features and waterfalls in water
gardens.
Design Features
- Stainless steel pump casing
- Stainless steel suction grid, plate and base
- Die Cast stainless steel impeller
- 10m H07 RN-F power supply cable with plug in the
single phase 220 V 50Hz version
- Fixed double NBR 70 rubber seal with special sand
guard V-ring
- Oil chamber for seal lubrication
- Stainless steel shaft with ceramic facing at the points
of wear
- Equipped with 1" F plastic reducer
Motor
- Dry motor with stainless steel casing
- Level of protection IP68
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Completely insulated cable connection chamber
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clear water, free of solids
- Maximum liquid temperature 40C
- Maximum submersion under the water level 7m
- Free 1.5 mm clearance. For water features with a
lesser clearance insert the sponge filter (optional) in
the hydraulics
Applications
- For fountains, water features, waterfalls in water
gardens
Accessories (optional)
- Vulcano: adjustable water feature with three level
jets
- Gaiser: adjustable water feature with a single foamyjet
- Campana: adjustable bell-shaped water feature
- Filters: sponge to be used for water features with
clearances under 1.5 mm
Dimensions mm.

Model

Weight

Free Clearance

DNM

Kg

VERSAILLES 80/7

144

231

403

1,5

1 1/4"

6,7

VERSAILLES 160/8

144

231

425

1,5

1 1/4"

VERSAILLES 250/10

285

372

620

1,5

1 /4"

7,8

VERSAILLES 350/12

285

372

620

1,5

1 1/4"

9,3

MODEL

Nominal
Power
HP

Absorbed
Power

kW

HP

VOLTAGE

Amp.

F.

Ql/1'

N2121000

VERSAILLES 80/7

0,3

0,2

0,4

0,3

1 ~ 220 240 V

1,3

6,3

N2121010

VERSAILLES 160/8

0,5

0,37

0,6

0,45 1 ~ 220 240 V

2,2

N2121020

VERSAILLES 250/10 0,75

0,55

1,2

0,9

1 ~ 220 240 V

4,5

10

N2121030

VERSAILLES 350/12

1,1

0,8

1,6

1,2

1 ~ 220 240 V

5,1

16

ZB401690

VULCANO

ZB401700

GAISER

ZB401710

CAMPANA

ZB401720

FILTRO 1 PER MOD. 80/7 - 160/8

ZB401730

FILTRO 2 PER MOD. 250/10 - 350/12

192

DIAMETER AND HEIGHT OF WATER


FEATURES in cm
VULCANO

kW
Discharge Head
in meters

CODE

GAISER

CAMPANA

150 - H 230

15 - H 45

80 - H 45

180 - H 360

20 - H 110

90 - H 45

230 - H 500

30 - H 180

95 - H 45

300 - H 600

50 - H 250

100 - H 45

PRICE

VERSAILLES
VULCANO

GAISER

CAMPANA

193

PRESSURE ASSEMBLIES

50 Hz

PRESSURE ASSEMBLIES
SIZING HOME WATER SYSTEMS
The fundamental data for selecting a pressure assemblie unit is:
a)
the water flow rate required at the moment of maximum usage
b)
the total delivery head
The flow rate required may be taken from the average statistical values diagram shown below (Fig. No. 1).
The calculation of the total delivery head (which corresponds to the minimum unit working pressure) provides for three different cases:
A)
supply from a deposit at the same level as the unit
B)
supply from a mains water supply system or deposit higher than the unit
C)
supply from a well or deposit situated lower than the unit
Case A) The height of the highest sampling point is added to the pressure value required at that point plus any flow resistance. (See
example Fig. No. 2)
Case B) Proceed as per case A, then take from the figure obtained the actual pressure value of the water supply system or the pressure
value developed as a result of the drop from the deposit. (See example Fig. No. 3)
Case C) Proceed as per case A, then add to the figure obtained the value in metres between the water level and the unit. (see Fig. No.
4)
The figures obtained compared with the tables specifying the features of the different autoclave units shown in the catalogue will allow
the most suitable unit to be selected. You must consider that in these tables the highest minimum tap pressure provided for is 1.5 atm.
The information outlined is of a general nature as the different specific conditions of use cannot be taken into consideration.

Fig. 1
FLATS (2 wcS)

50
40

60

30

IC

TE

ES
M

18

200

65

150

70

100

75

63

20

60

ES

57

ST

300

NS

50

IO

60

UT

43

50

IT

80

LS

30

ST

100

TE

20

500

IN

200

O
F
PA F
R

17

NUMBER OF PEOPLE

16
14
66

12
10
5

7 8 9 10

12 14 16

18 20

30

40

60 80 100

m3/h
% CALCULATED CONTEMPORANEOUSNESS % CALCULATED CONTEMPORANEOUSNESS

CURVES FOR WC WITH FLUSH CISTERNS


(FOR WC WITH FAST RATE FLUSHINGS + 30%)

195

80

PRESSURE ASSEMBLIES
Fig. 2

Min. pressure 1,5 ATM

HE

CASE A
H building
Minimum pressure
Flow resistance

Deposit

18 +
15 +
2=
Meters

35

HE = Building height 18 m.

Fig. 3
Deposit

HD

Min. pressure 1,5 ATM

CASE B
Head necessary
Mains water supply pressure

35 20 =

Meters

15

Pressure necessary
The tank
Public water
supply system
pressure 2 ATM

35 20 =
Meters

15

HD = Deposit height 20 m.

Fig. 4

Min. pressure 1,5 ATM

CASO C
Head necessary
Suction Height

35 +
5=

HA

Meters

HA = Suction height 5 m.

196

40

PRESSURE ASSEMBLIES
FLOW RESISTANCE AND WATER SPEED TABLE
GALVANISED PIPES - NEW

FLOW RATE

NOMINAL DIAMETERS IN INCHES AND IN MILLIMETRES


1

lt./sec.

0,6

10

0,16

0,855

0,470

0,292

9,910

2,407

0,784

0,9

15

0,25

1,282

0,705

0,438

0,249

20,11

4,862

1,570

0,416

1,2

20

0,33

1,710

0,940

0,584

0,331

0,249

33,53

8,035

2,588

0,677

0,346

2,138

1,174

0,730

0,415

0,312

49,93

11,91

3,834

1,004

0,510

2,565

1,409

0,876

0,498

0,374

0,231

16,50

5,277

1,379

0,700

0,223

25

0,42

1"
27,00

11/2"
41,25

lt./min.

1,5

/4"
21,25

11/4"
35,75

m3/h

/2"
15,75

2"
52,50

21/2"
68,00

3"
80,25

31/2"
92,50

4"
105,0

5"
130,0

6"
155,5

Large numbers: Flow resistance in m for


every 100 m of piping
Small numbers: Water speed in metres
per second

1,8

30

0,50

69,34

2,1

35

0,58

2,993

1,644

1,022

0,581

0,436

0,269

91,54

21,75

6,949

1,811

0,914

0,291

2,4

40

0,67

1,879

1,168

0,664

0,499

0,308

27,66

8,820

2,290

1,1160

0,368

3,0

50

0,83

2,349

1,460

0,830

0,623

0,385

0,229

41,40

13,14

3,403

1,719

0,544

0,159

3,6

60

1,00

2,819

1,751

0,996

0,748

0,462

0,275

57,74

18,28

4,718

2,375

0,751

0,218

4,2

70

1,12

3,288

2,043

1,162

0,873

0,539

0,321

0,231

76,49

24,18

6,231

3,132

0,988

0,287

0,131

4,8

80

1,33

2,335

1,328

0,997

0,616

0,376

0,263

30,87

7,940

3,988

1,254

0,363

0,164

5,4

90

1,50

2,627

1,494

1,122

0,693

0,413

0,296

38,30

9,828

4,927

1,551

0,449

0,203

6,0

100

1,67

2,919

1,660

1,247

0,770

0,459

0,329

0,248

46,49

11,90

5,972

1,875

0,542

0,244

0,124

7,5

125

2,08

3,649

2,075

1,558

0,962

0,574

0,412

0,310

0,241

70,41

17,93

8,967

2,802

0,809

0,365

0,185

0,101

9,0

150

2,50

2,490

1,870

1,154

0,688

0,494

0,372

0,289

25,11

12,53

3,903

1,124

0,506

0,256

0,140

10,5

175

2,92

2,904

2,182

1,347

0,803

0,576

0,434

0,337

33,32

16,66

5,179

1,488

0,670

0,338

0,184

12

200

3,33

3,319

2,493

1,539

0,918

0,659

0,496

0,385

0,251

42,75

21,36

6,624

1,901

0,855

0,431

0,234

0,084

15

250

4,17

4,149

3,117

1,924

1,147

0,823

0,620

0,481

0,314

64,86

32,32

10,03

2,860

1,282

0,646

0,350

0,126

18

300

5,00

3,740

2,309

1,377

0,988

0,744

0,577

0,377

0,263

45,52

14,04

4,009

1,792

0,903

0,488

0,175

0,074

24

400

6,67

4,987

3,078

1,836

1,317

0,992

0,770

0,502

0,351

78,17

24,04

6,828

3,053

1,530

0,829

0,294

0,124

30

500

8,33

3,848

2,295

1,647

1,240

0,962

0,628

0,439

36,71

10,40

4,622

2,315

1,254

0,445

0,187

36

600

10,0

4,618

2,753

1,976

1,488

1,155

0,753

0,526

51,84

14,62

6,505

3,261

1,757

0,623

0,260

42

700

11,7

3,212

2,306

1,736

1,347

0,879

0,614

19,52

8,693

4,356

2,345

0,831

0,347

48

800

13,3

3,671

2,635

1,984

1,540

1,005

0,702

25,20

11,18

5,582

3,009

1,066

0,445

54

900

15,0

4,130

2,964

2,232

1,732

1,130

0,790

31,51

13,97

6,983

3,762

1,328

0,555

60

1000

16,7

4,589

3,294

2,480

1,925

1,256

0,877

38,43

17,06

8,521

4,595

1,616

0,674

75

1250

20,8

4,117

3,100

2,406

1,5701,883

1,097

26,10

13,00

7,010

2,458

1,027

90

1500

25,0

4,941

3,720

2,887

2,197

1,316

36,97

18,42

9,892

3,458

1,444

105

1750

29,2

4,340

3,368

2,511

1,535

24,76

13,30

4,665

1,934

120

2000

33,3

4,960

3,850

3,139

1,754

31,94

17,16

5,995

2,496

150

2500

41,7

180

3000

50,0

5,023

2,632

13,05

5,417

240

4000

66,7

22,72

8,926

300

5000

83,3

4,812

3,767

2,193

26,26

9,216

3,807

3,509
4,386

14,42

N.B. - To evaluate the flow resistance in pipes made of different materials, the value found for the galvanised pipe must be
multiplied by the following set coefficients:
0,6 for PVC pipes
0,7 for aluminium pipes
0,8 for rolled steel pipes
1,3 for cement fibre pipes

197

PRESSURE ASSEMBLIES WITH ONE PUMP


WATERPRESS 60/50
The WATERPRESS 60/50 is a booster set produced
with NEWJET self-priming centrifugal pump.
The WATERPRESS 60/50 is supplied wired, tested
and complete with expansion tank.
Design Features
- Cast iron pump casing
- Die-cast aluminium motor bracket
- Technopolymer impeller with stainless steel shim
ring
- Monobloc technopolymer diffusor-Venturi tube-nozzle
assembly
- Stainless steel shaft
- Graphite mechanical seal with ceramic counterface
- Pressure switch (max 6 bar) calibrated at:
min. 2 - max. 3 bar
- Pressure gauge
- 24 Lt steel expansion tank with interchangeable
food-quality rubber diaphragm
- Flexible pipe for water connection
- 1.5 m H05 RN-F power supply cable with plug

48

Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use

40
32

16
8

Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation

Hm
Q

WATERPRESS 60/50

WATERPRESS 60/50

30
1,8

20
1,2

10
0,6

50
3

40
2,4

Weight

DNA

DNM

kg

510

430

470

260

1" F

1" F

14,5

Nominal
Power

HP

N5209160

L / 1'
m3/ h

Dimensions mm.

Model

MODEL

60/5

24

Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height 8m with foot valve
- Maximum operating pressure 6 bar

CODE

WP

kW

Absorbed
Power

HP

0,75 0,55 1,1

10

40

50

m /h

0,3 1,2 1,8 2,4

Discharge
Head
in meters

46

36

L/1'

VOLTAGE

Amp.

F.

kW

0,8 1 ~ 220 240 V

198

10

20

30

PRICE

Q
3

31

24

WATERPRESS
WATERPRESS 70/50
The WATERPRESS 70/50 is a booster set produced
with JET self-priming centrifugal pump.
The WATERPRESS 70/50 is supplied wired, tested
and with expansion tank.
Design Features
- Cast iron pump casing
- Cast iron motor bracket
- Technopolymer impeller, Venturi tube and nozzle
- Technopolymer diffusor, with stainless steel shim
ring
- Stainless steel shaft
- Graphite mechanical seal with ceramic counterface
- Pressure switch (max 6 bar) calibrated at:
min. 2 - max. 3 bar
- Pressure gauge
- Pressed brass 3 way fitting
- 24 Lt steel expansion tank with interchangeable
food-quality rubber diaphragm
- Flexible pipe for water connection
- 1.5 m H05 RN-F power supply cable with plug
Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use

50

7 0/5

10
Hm
Q

L / 1'
m3/ h

30
1,8

20
1,2

10
0,6

50
3

40
2,4

60
3,6

WATERPRESS 70/50

1,36

DNA

DNM

kg

520

460

550

315

1" F

1" F

22,3

kW

Weight

Nominal
Power

HP

80
4,8

70
4,2

Dimensions mm.

Model

N5209730 WATERPRESS 70/50

SS

20

Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation

MODEL

PRE

30

Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height 8m with foot valve
- Maximum operating pressure 6 bar

CODE

WA
TE R

40

Absorbed
Power

HP

1,5

VOLTAGE

Amp.

F.

kW

1,1 1 ~ 220 240 V

199

16

20

30

70

L/1'

10

40

50

60

m3/h

0,3 1,2 1,8 2,4

3,6 4,2

Discharge
Head
in meters

50

PRICE

46

41

37

32

28

18

PRESSURE ASSEMBLIES WITH ONE PUMP


WATERPRESS INOX 70/50
The WATERPRESS INOX 70/50 is a booster set
produced with JETINOX self-priming centrifugal pump.
The WATERPRESS INOX 70/50 is supplied wired,
tested and complete with expansion tank.
Design Features
- Pump casing in AISI 304 stainless steel
- Die-cast aluminium motor bracket
- Technopolymer impeller with stainless
steel shim ring
- Monobloc technopolymer diffusor-Venturi tube-nozzle
assembly
- Stainless steel shaft
- Graphite mechanical seal with ceramic counterface
- Technopolymer seal holder plate
- Pressure switch (max 6 bar) calibrated at:
min. 2 - max. 3 bar
- Pressure gauge
- Chromium plated pressed brass 5 way fitting
- 24 Lt steel expansion tank with interchangeable
food-quality rubber diaphragm
- Flexible pipe for water connection
- 1.5 m H05 RN-F power supply cable with plug

60
50

Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use

40

WP

30

X7

0/

20

Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height 8m with foot valve
- Maximum operating pressure 6 bar

Hm
Q

50

40
2,4

60
3,6

Weight

DNA

DNM

kg

520

445

565

260

1" F

1" F

13,8

Nominal
Power

HP

80
4,8

70
4,2

Dimensions mm.

WATERPRESS INOX 70/50

N5209750 WATERPRESS INOX 70/50

30
1,8

20
1,2

10
0,6

L / 1'
m3/ h

Model

MODEL

50

10

Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation

CODE

INO

Absorbed
Power

kW

HP

0,95 0,7

1,36

Amp.

F.

kW

1,0 1 ~ 220 240 V

4,5

200

16

20

30

70

10

40

50

60

m /h

0,3 1,2 1,8 2,4

3,6 4,2

Discharge
Head
in meters

48

L/1'

VOLTAGE

PRICE

Q
3

42 37,5 31

25

16

WATERPRESS INOX
WATERPRESS INOX 80/48
The WATERPRESS INOX 80/48 is a booster set
produced with MAX self-priming multistage centrifugal
pump. The WATERPRESS INOX 80/48 is supplied
wired, tested and complete with steel expansion tank.
Design Features
- AISI 304 stainless steel pump casing
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel shim
ring
- Technopolymer diffusors
- AISI 304 stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic counterface
- Pressure switch (max 6 bar) calibrated at:
min. 2 - max. 3 bar
- Pressure gauge
- Chromium plated pressed brass 5 way fitting
- 24 Lt steel expansion tank with interchangeable
food-quality rubber diaphragm
- Flexible pipe for water connection
- 1.5 m H05 RN-F power supply cable with plug

60

Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use

50
40

WP

30

Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height recommended 7 m with
foot valve
- Maximum operating pressure 7 bar

Hm
Q

L / 1'
m3/ h

10

20

30

40

50

60

70

80

0,6

1,2

1,8

2,4

3,6

4,2

4,8

Weight

DNA

DNM

kg

520

430

550

260

1" F

1" F

12,3

Nominal
Power

HP

WATERPRESS INOX 80/48

Dimensions mm.

WATERPRESS INOX 80/48

N5301110

0 /4

10

Model

MODEL

X8

20

Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation

CODE

INO

Absorbed
Power

kW

HP

0,75 0,55

1,1

VOLTAGE

Amp.

F.

kW

0,8 1 ~ 220 240 V

4,0

201

12,5

20

30

70

L/1'

10

40

50

60

m3/h

0,3 1,2 1,8 2,4

3,6 4,2

Discharge
Head
in meters

45

PRICE

41

36

32

28

22

17

10

PRESSURE ASSEMBLIES WITH ONE PUMP


WATERPRESS INOX 80/48 50 L
The WATERPRESS INOX 80/48 50 L is a booster set
produced with MAX self-priming multistage centrifugal
pump.
The WATERPRESS INOX 80/48 50 L is supplied wired,
tested and complete with 50 Lt steel expansion tank.
Design Features
- AISI 304 stainless steel pump casing
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel shim
ring
- Technopolymer diffusors
- AISI 304 stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic counterface
- Pressure switch (max 6 bar) calibrated at:
min. 2 - max. 3 bar
- Pressure gauge
- Chromium plated pressed brass 5 way fitting
- 50 Lt steel expansion tank with interchangeable
food-quality rubber diaphragm
- Flexible pipe for water connection
- 1.5 m H05 RN-F power supply cable with plug

60

Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use

50
40
30

Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height recommended 7 m with
foot valve
- Maximum operating pressure 7 bar

MODEL

0 /4

Hm
Q

L / 1'
m3/ h

10

20

30

40

50

60

70

80

0,6

1,2

1,8

2,4

3,6

4,2

4,8

Dimensions mm.

Weight

DNA

DNM

kg

640

520

640

370

1" F

1" F

18

Nominal
Power

HP

N5301140

X8

10

Model

CODE

INO

20

Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation

WATERPRESS INOX 80/48 50L

WP

Absorbed
Power

kW

HP

WATERPRESS INOX 80/48 50L 0,75 0,55

1,1

VOLTAGE

Amp.

F.

kW

0,8 1 ~ 220 240 V

202

4,0

12,5

20

30

70

L/1'

10

40

50

60

m3/h

0,3 1,2 1,8 2,4

3,6 4,2

Discharge
Head
in meters

45

PRICE

41

36

32

28

22

17

10

WATERPRESS INOX 50 L
WATERPRESS INOX 120/60 50 L
The WATERPRESS INOX 120/60 50 L is a booster
set produced with MAX self-priming multistage
centrifugal pump.
The WATERPRESS INOX 120/60 50 L is supplied
wired, tested and complete with 50 Lt steel expansion
tank.
Design Features
- AISI 304 stainless steel pump casing
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel shim
ring
- Technopolymer diffusors
- AISI 304 stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic counterface
- Pressure switch: electronic control and protection
device AQUA TROL (adjustable starting pressure
from 1,5 to 3 bar)
- Pressure gauge
- Chromium plated pressed brass 5 way fitting
- 50 Lt steel expansion tank with interchangeable
food-quality rubber diaphragm
- Flexible pipe for water connection
- 1.5 m H05 RN-F power supply cable with plug

60

Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use

50
40

10
Hm
Q

N5301130

20
1,2

L / 1'
m3/ h

60
3,6

40
2,4

100
6

80
4,8

Dimensions mm.

Model

MODEL

12
0/6
0

20

Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation

CODE

IN
OX

30

Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height recommended 7 m with
foot valve
- Maximum operating pressure 7 bar

WATERPRESS INOX 120/60 50L

WA
TE
RP
RE
SS

120
7,2

Weight

DNA

DNM

kg

640

520

640

370

1" F

1" F

21

Nominal
Power

Absorbed
Power

HP

kW

HP

WATERPRESS INOX 120/60 50L 1,2

0,9

1,7

VOLTAGE

Amp.

F.

kW

1,25 1 ~ 220 240 V

203

5,8

20

L/1'

20

40

60

80

m3/h

1,2

2,4

3,6

4,8

Discharge
Head
in meters

60

55

48

36

26

PRICE

WATERPRESS SUPERINOX
WATERPRESS SUPERINOX
The WATERPRESS SUPERINOX is a booster set
produced with JETINOX self-priming centrifugal pump.
The WATERPRESS SUPERINOX is supplied wired,
tested and complete with stainless steel expansion
tank.
Design Features
- Pump casing in AISI 304 stainless steel
- Die-cast aluminium motor bracket
- Technopolymer impeller with stainless steel shim
ring
- Monobloc technopolymer diffusor-Venturi-nozzle
assembly
- Stainless steel shaft
- Graphite mechanical seal with ceramic counterface
- Technopolymer seal holder plate
- Pressure switch (max 6 bar) calibrated at:
min. 2 - max. 3 bar
- Pressure gauge
- Chromium plated pressed brass 5 way fitting
- Stainless steel expansion tank with interchangeable
food-quality rubber diaphragm
- Flexible pipe for water connection
- 1.5 m H05 RN-F power supply cable with plug

48
40
32

Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use

24

60/

50

16
8

Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height 8m with foot valve
- Maximum operating pressure 6 bar

Hm
Q

L / 1'
m3/ h

10
0,6

30
1,8

20
1,2

50
3

40
2,4

60
3,6

80
4,8

70
4,2

Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation

Dimensions mm.

Model

WATERPRESSSUPERINOX 60/50

CODE

MODEL

Weight

530

425

550

280

Nominal
Power

Absorbed
Power

HP

kW

HP

kW

N5209680 WATERPRESSSUPERINOX 60/50 0,75

0,55

1,1

0,8

VOLTAGE

Amp.

1 ~ 220 240 V

204

F.

12,5

DNA
1" F

L/1'

DNM

kg

1" F

11,2

10

20

30

40

50

60

80

m /h

0,6

1,2

1,8

2,4

3,6

4,8

Discharge
Head
in meters

46

36

31

26

18

Q
3

PRICE

HYDRAULIC AND ELECTRIC ACCESSORIES

50 Hz

ACCESSORIES
HYDRAULIC ACCESSORIES
CODE

MODEL

DESCRIPTION

ZA004520

KA4

SUCTION KIT 4 m

ZA003830

KA7

SUCTION KIT 7 m

ZA004080

NIPPLEX 1 M-M

1 MALE THREADED NIPPLE FOR SUCTION KIT

ZA000900

RCF 30

1 1/4

FEMALE ELBOW HOSE HOLDER 30 mm

ZA000910

RCF 40

FEMALE ELBOW HOSE HOLDER 40 mm

ZA000920

RCF 50

ZA000270

TF 500

1 x mm 500 M-F

FLEXIBLE PIPE

ZA003060

TF 600

1 x mm 600 M-F

FLEXIBLE PIPE

ZA003160

TF 700

1 x mm 700 M-F

FLEXIBLE PIPE

ZA003070

TF 800

1 x mm 800 M-F

FLEXIBLE PIPE

ZA007430

GA 1 1/4

1 1/4 x mm 400 M-F FLEXIBLE PIPE

ZA007440

GA 2

2 x mm 500 M-F

ZA007450

GA 2 1/2

2 1/2 x mm 500 M-F FLEXIBLE PIPE

ZA007460

GA 3

3 x mm 500 M-F

ZA002030

MAR 6

6 BAR RADIAL MOUNTING PRESSURE GAUGE

ZA005170

MAP 6

6 BAR REAR MOUNTING PRESSURE GAUGE

ZA000680

MAR 10

10 BAR RADIAL MOUNTING PRESSURE GAUGE

ZA000780

MAP 10

10 BAR REAR MOUNTING PRESSURE GAUGE

207

1/2

FEMALE ELBOW HOSE HOLDER 50 mm

FLEXIBLE PIPE
FLEXIBLE PIPE

PRICE

ACCESSORIES
HYDRAULIC ACCESSORIES
CODE

MODEL

DESCRIPTION

N2054010

PAF

CAST IRON CONNECTING FOOT

ZA008450

PAA

STAINLESS STEEL CONNECTING FOOT FOR


VACUSYSTEM (mod. 170S - 400 Twin)

ZB401770

PRESSED STEEL BASE KIT WITH SCREWS FOR

B1

MCX 80-120 E JETINOX 45-60


ZB41780

PRESSED STEEL BASE KIT WITH SCREWS FOR

B2

MCX 200 E JETINOX 90

ZA000240

R3V

3 WAY BRASS FITTING 1

ZA000260

R5V

5 WAY BRASS FITTING 1

ZA000020
ZA003000
ZA003190
ZA003200
ZA003210
ZA002020
ZA003220
ZA003230
ZA003240
ZA008430

VF 1
VFF 1
VFF 1 1/4
VFF 1 1/2
VFF 2
VAR 1
VAR 1 1/4
VAR 1 1/2
VAR 2
RVFF 2

1
PLASTIC FOOT VALVE
1
BRASS FOOT VALVE WITH STAINLESS STEEL FILTER
1 1/4 BRASS FOOT VALVE WITH STAINLESS STEEL FILTER
1 1/2 BRASS FOOT VALVE WITH STAINLESS STEEL FILTER
2
BRASS FOOT VALVE WITH STAINLESS STEEL FILTER
1
BRASS NON RETURN VALVE
1 1/4 BRASS NON RETURN VALVE
1 1/2 BRASS NON RETURN VALVE
2
BRASS NON RETURN VALVE
2
BALL VALVE WITH FULL BORE

ZA009330

VRP 1 1/4

STAINLESS STEEL BALL CHECK VALVE 1 1/4 F

ZA009320

VRP 1 1/2

STAINLESS STEEL BALL CHECK VALVE 1 1/2 F

ZA009310

VRP 2

STAINLESS STEEL BALL CHECK VALVE 2 F

ZA006450
ZA006460
ZA006570
ZA006470
ZA006610
ZA007000
D3114KKK
D3104KKK

VES INOX N 8
VES INOX N 20
VES INOX N 24
VES INOX N 24 H
VAA 24
KAA
FLEXINOX V 20
FLEXINOX SB 20

VERTICAL 8 LT STAINLESS STEEL EXPANSION TANK 6 BAR


VERTICAL 20 LT STAINLESS STEEL EXPANSION TANK 6 BAR
VERTICAL 24 LT STAINLESS STEEL EXPANSION TANK 6 BAR
HORIZONTAL 24 LT STAINLESS STEEL EXPANSION TANK 6 BAR
24 LITRE STAINLESS STEEL TANK FOR AIR FEEDER 6 BAR
AIR FEEDER KIT FITTING AND FLEXIBLE
FLEXINOX 87 EXPANSION TANK - 20 LITER VERTICAL 10 BAR
FLEXINOX 87 EXPANSION TANK - 20 LITER S/B VERTICAL 10 BAR

ZA003860
ZA000140
ZA003850
ZA009120-CE
ZA009070-CE
ZA009130-CE
ZA009080-CE
ZA009090-CE
ZA009100-CE
ZA009110-CE

VES 2
VES 24
VES 24 H
VEC 60 H
VEC 60 V
VEC 100 H
VEC 100 V
VEC 200 V
VEC 300 V
VEC 500 V

2 LITER EXPANSION TANK 6 BAR


VERTICAL 24 LITER EXPANSION TANK 6 BAR
HORIZONTAL 24 LITER EXPANSION TANK 6 BAR
HORIZONTAL 60 LITER EXPANSION TANK 10 BAR
VERTICAL 60 LITER EXPANSION TANK 10 BAR
HORIZONTAL 100 LITER EXPANSION TANK 10 BAR
VERTICAL 100 LITER EXPANSION TANK 10 BAR
VERTICAL 200 LITER EXPANSION TANK 10 BAR
VERTICAL 300 LITER EXPANSION TANK 10 BAR
VERTICAL 500 LITER EXPANSION TANK 10 BAR

208

PRICE

ACCESSORIES
HYDRAULIC ACCESSORIES
CODE
D6024KKK
ZA006380
ZA003050
ZA000790
ZA009190
ZA009200
ZA009210
ZA009220
ZA009230
CODE

MODEL
MBF
MBB
MGS 2
MGS 24
MB 60
MB 100
MB 200
MB 300
MB 500

DESCRIPTION

PRICE

BROMOBUTYL DIAPHRAGM FOR FLEXINOX 20 LITER TANKS


BROMOBUTYL DIAPHRAGM FOR INOX TANKS
FOOD-QUALITY RUBBER DIAFHRAGM FOR 2 LITER TANK
FOOD-QUALITY RUBBER DIAFHRAGM FOR 24 LITER TANK
FOOD-QUALITY RUBBER DIAFHRAGM FOR 60 LITER TANK
FOOD-QUALITY RUBBER DIAFHRAGM FOR 100 LITER TANK
FOOD-QUALITY RUBBER DIAFHRAGM FOR 200 LITER TANK
FOOD-QUALITY RUBBER DIAFHRAGM FOR 300 LITER TANK
FOOD-QUALITY RUBBER DIAFHRAGM FOR 500 LITER TANK

MODEL

DESCRIPTION

PRICE

ZA008290

CS 85

SEALED LID FOR VACUSYSTEM 85 LITER TANK

ZA008310

RS 170

SCREW EXTENSION FOR VACUSYSTEM 170/400 LITER TANK

FILTERS AND FILTERING CARTRIDGES


CODE

m
nom.

DESCRIPTION

ZB401390

ANTI-SCALE FILTER COMPLETE ( FOR WASHING MACHINE)

ZB900010

5 FILTER 1 CONNECTION

ZB900060

7 FILTER 1 CONNECTION

ZB900020

7 FILTER 1 1/4 CONNECTION

ZB900030

10 FILTER 1 CONNECTION

ZB900070

10 FILTER 1 1/4 CONNECTION

ZB401350

5 CARTRIDGE FA (WOUND WIRE)

20

20

ZB401370

5 CARTRIDGE NY (NYLON MESH)

60

20

ZB401410

7 CARTRIDGE FA (WOUND WIRE) FOR FILTER 1 CONNECTION

20

20

ZB401460

7 CARTRIDGE FA (WOUND WIRE) FOR FILTER 1 1/4 CONNECTION

20

20

ZB401550

7 CARTRIDGE NY (NYLON MESH) FOR FILTER 1 CONNECTION

60

20

ZB401540

7 CARTRIDGE NY (NYLON MESH) FOR FILTER 1 1/4 CONNECTION

60

20

ZB401360

10 CARTRIDGE FA (WOUND WIRE) FOR FILTER 1 CONNECTION

20

20

ZB401570

10 CARTRIDGE FA (WOUND WIRE) FOR FILTER 1 1/4 CONNECTION

20

20

ZB401380

10 CARTRIDGE NY (NYLON MESH) FOR FILTER 1 CONNECTION

60

20

60

20

1/4

CONNECTION

ZB401580

10 CARTRIDGE NY (NYLON MESH) FOR FILTER 1

ZB401420

10 CARTRIDGE CA (NYLON MESH + ACTIVE CARBON)

60

20

ZB401620

10 CARTRIDGE PL (CRYSTALLINE POLYPHOSPHATE)

ZA006640

FILTRATION KIT COMPLETE WITH CARTRIDGES

20

ZB401470

5 CARTRIDGE CA (NYLON MESH + ACTIVE CARBON)

60

ZB401480

5 CARTRIDGE IX (PLEATED STAINLESS STEEL)

80

ZB401500

5 CARTRIDGE KZ (QUARTZ)

30

ZB401560

7 CARTRIDGE CA (NYLON MESH + ACTIVE CARBON)

60

ZB401510

7 CARTRIDGE IX (PLEATED STAINLESS STEEL)

80

ZB401530

7 CARTRIDGE KZ (QUARTZ)

30

ZB401590

10 CARTRIDGE IX (PLEATED STAINLESS STEEL)

80

ZB401610

10 CARTRIDGE KZ (QUARTZ)

30

In exhaustion

209

PRICE

ACCESSORIES
ELECTRICAL ACCESSORIES
CODE

MODEL

UZB00500

AQUA MATIC

UZB00600

AQUA MATIC

DESCRIPTION

PRICE

ELECTRONIC CONTROL AND PROTECTION


DEVICE FOR ELECTRIC PUMPS

(wired)

UZB00200

AQUA TROL

UZB00400

AQUA TROL

ELECTRONIC CONTROL AND PROTECTION


DEVICE FOR ELECTRIC PUMPS WITH EXPANSION TANK

(wired)

ZA003110

PM 5 ITAL

PRESSURE SWITCH

- 6 ATM - ITALTECNICA

ZA006400

PM 12 ITAL

PRESSURE SWITCH

- 12 ATM - ITALTECNICA

ZA000630

PT 6 TEL

PRESSURE SWITCH

- 6 ATM - TELEMECANIQUE

ZA000640

PT 12 TEL

PRESSURE SWITCH

- 12 ATM - TELEMECANIQUE

ZA000590

MICROSTART 3-3

3 M FLOAT 3 WIRES FOR EMPTYING/FILLING

ZA000330

MICROSTART 10-3

10 M FLOAT 3 WIRES FOR EMPTYING/FILLING

ZA000650

MICROSTART 5-2

ZA000750

MICROSTART 10 -2

ZA000350

MICROSTART S 5-2

5 M FLOAT 2 WIRES WITH PLUG AND SOCKET

ZA000390

MICROSTART S10-2

10 M FLOAT 2 WIRES WITH PLUG AND SOCKET

ZA000820

CP

COUNTERWEIGHT FOR FLOAT

ZA008120

MERCURY 15 M

15 MT FLOAT SWITCH MERCURY MC

ZA000420

CAVO 4 x 1

NEOPRENE HO7 RNF 4 WIRE CABLE 1,5 MM WIRES

ZA000430

CAVO 4 x 1,5

NEOPRENE HO7 RNF 4 WIRE CABLE 1,5 MM WIRES

ZA000440

CAVO 4 x 2,5

NEOPRENE HO7 RNF 4 WIRE CABLE 2,5 MM WIRES

ZA000450

CAVO 4 x 4

NEOPRENE HO7 RNF 4 WIRE CABLE 4 MM

ZA000460

CAVO 4 x 6

NEOPRENE HO7 RNF 4 WIRE CABLE 6 MM

ZA000470

CAVO 4 x 10

NEOPRENE HO7 RNF 4 WIRE CABLE 10 MM WIRES

ZA003370

GIUNZIONE 2,5

joint with thermoretractable units for cables up to 4 x 2,5

ZA003390

GIUNZIONE 6

joint with thermoretractable units for cables up to 4 x 6

ZA003380

GIUNZIONE 10

joint with box for cables up to 4 x 10

5 M FLOAT 2 WIRES FOR FILLING


10 M FLOAT 2 WIRES FOR FILLING

2
2
2

WIRES
WIRES
2

210

ACCESSORIES
CONTROL PANELS

AMC 10

AMCS 10

AM 10

AT 10

AD 10

AY 10

AR 10

AA 10

ADRM 10

211

ACCESSORIES
CONTROL PANELS

ADRD 10

ADRY 10

ADRM 20

ADRD 20

ADRY 20

QCL - MCL - ECL - AOA

QES M

QES T

QES

212

ACCESSORIES
CONTROL PANELS
CODE

MODEL

VOLTAGE
at 50 Hz

MOTOR Nominal Power


kW
HP

RANGE

CAPAC.

Control Panels for 1 single phase Submersible pump

1~230
1~230
1~230
1~230
1~230
1~230
Control Panels pre-set for level control for 1 single phase Submersible pump

1~230
1~230
1~230
1~230
1~230
1~230
Control Panels pre-set for level control for 1 single phase Submersible pump

1~230
1~230
1~230
1~230
1~230
Control Panels pre-set for level control for 1 three phase Submersible or Surface-Centrifugal pump - Direct Start

3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels with level control device for 1 three phase Submersible or Surface-Centrifugal pump - Direct Start

3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400

213

PRICE

ACCESSORIES
CONTROL PANELS
CODE

MODEL

VOLTAGE
at 50 Hz

MOTOR Nominal Power


kW
HP

RANGE
Amin.
Amax.

CAPAC.

Control Panels with level control device for 1 three phase Surface-Centrifugal pump - Star/Triangle Start

3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels with level control device for 1 three phase Submersible pump - Reactance Start

3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels with level control device for 1 three phase Submersible pump - Auto-Transformer Start

3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels for 1 single phase Sump, Sewage and Effluent pump

1~230
1~230
1~230
1~230
1~230

214

PRICE

ACCESSORIES
CONTROL PANELS
CODE

MODEL

VOLTAGE
at 50 Hz

MOTOR Nominal Power

RANGE

Control Panels for 1 three phase Sump, Sewage and Effluent pump - Direct Start

3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels for 1 three phase Sump, Sewage and Effluent pump - Star/Triangle Start

3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels for 2 single phase Sump, Sewage and Effluent pumps

1~230
1~230
1~230
1~230
1~230
Control Panels for 2 three phase Sump, Sewage and Effluent pumps - Direct Start

3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels for 2 three phase Sump, Sewage and Effluent pumps - Star/Triangle Start

3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400

215

CAPAC.

PRICE

ACCESSORIES
CONTROL PANELS

Control Panels and modules for conductive fluids

CODE

VOLTAGE
at 50 Hz

MODEL

PRICE

QCL5 Level Control Panel 5A


MCL5/BD Level Module 10A b.DIN
MCL5/Z Level Module 5A
QCL10 Level Control Panel 10A

Accessories for Control Panels

CODE

PRICE

MODEL
Electrodes for conductive fluids level control
12Vcc Acoustical and Optical Alarm system for Sump, Sewage and Effluent pumps Control Panels

Control Panels for single and three phase Submersible pumps


CODE
ZQ000080
ZQ000090
ZQ000100
ZQ000110
ZQ000120
ZQ000130
zq000140
ZQ000150
ZQ000160
ZQ000170
V000180
ZQ000190

MODEL

DESCRIPTION

QES HP 0,5 M
QES HP 0,5 T
QES HP 0,75 M
QES HP 0,75 T
QES HP 1 M
QES HP 1 T
QES HP 1,5 M
QES HP 1,5 T
QES HP 2 M
QES HP 2 T
QES HP 3 T
QES HP 4 T

Simple electromechanical panel with fixed thermal protection,


for controlling single phase pumps up to 2 HP and three phase
pumps up to 5,5 HP

PRICE

Control Panels for Sump, Sewage and Effluent pumps


CODE

MODEL

DESCRIPTION

ZQ001000

QEF-26

FOR MODELS:

DRENOX - BIOX - MINIVORT P2


MINIVORT PP2

ZQ001010

QEF-37

ELECTRIC PANEL FOR AUTOMATION ( 1,8 2,6 )


EQUIPPED WITH 10m CABLE FLOAT SWITCH
ELECTRIC PANEL FOR AUTOMATION ( 2,7 3,7 )
EQUIPPED WITH 10m CABLE FLOAT SWITCH

216

PRICE

AUTOMATIC PUMPING STATION


MINI COLLECTION AND PUMPING
STATIONS FOR WASTE WATER
The VACUSYSTEM 85 are pre-assembled ready-foruse automatic pumping stations, designed for the
disposal of domestic waste water in houses and small
blocks of flats.
Particularly suitable when the water from skin drains,
baths, washing machines (excluding that of WCs) etc.
is collected at a lower level than the main sewer.
Design Features
- The standard pumping station consists of:
- Tank
In polyethylene with a capacity of 85 litres with
corrosion and wear resistant sand filter bowl and
grid. Three possible types of 40 pipe inlet.
- DRENOX Submersible Pump
Models 160/8 AUT and 250/10 AUT with cast
stainless steel impeller (for the features please see
Data Sheet on page 125).
- Flexible pipe
1 1/4 helically wound complete with a sleeve for the
connection of the delivery pipe for both right-hand
and left-hand connection.

MOTOR PUMP INCLUDED

12
10

- Non return valve

- Plug
with built in thermal protection and switch for
manual/automatic operation.

Electric pump motor


- Dry motor
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Level of protection IP68
- Class F insulation
- Speed of rotation 2850 rpm
- Completely insulated cable connection chamber
- 10 m H07 RN-F power supply cable with plug

250
/10
16

0/ 8

2
Hm
Q

50
3

L / 1'
m3/ h

200
12

150
9

100
6

250
15

300
18

Usage Limitations
- Type of liquid: partially effluent and dirty clear water,
with suspended solids of a maximum dimension of
6 mm, non-aggressive liquids
- Maximum liquid temperature 40C
Accessories (only on request)
- Sealing lid to be fitted in place of the grid
(see page 209)

CODE

MODEL

Nominal
Power

Absorbed
Power

HP

kW

HP

VOLTAGE

Amp.

F.

L/1'

N2141000

VS 85-D 160

0,5

0,37

0,6

0,45 1 ~ 220 240 V

2,2

N2141010

VS 85-D 250

0,75

0,55

1,2

0,9

1 ~ 220 240 V

4,5

10

217

40

60

80

120 160 240 300

0,6

2,4

3,6

4,8

7,2

5,8

4,1

2,2

9,4

8,5

7,6

7,2

5,1

PRICE
3

m /h

kW

10

Discharge
Head
in meters

9,6 14,4

4,1

18

VACUSYSTEM
MINI COLLECTION AND PUMPING
STATIONS FOR WASTE WATER
The VACUSYSTEM 170s are pre-assembled, readyfor-use automatic pumping stations, designed for the
disposal of waste and sewage water.
Particularly suitable when the water from drains is
collected at a lower level than the main sewer.
Design Features
- The standard pumping station consists of:
- Tank
In polyethylene with a capacity of 170 litres with screwdown lid. Three possible types of inlet for water
collection or ventilation pipe inlet and cable glands for
the electric pump power supply cable and service
cables (overflow float on request).
- BIOX Submersible Pump
Models 200/8 AUT, 300/10 AUT, 400/12 AUT with cast
steel impellers .

MOTOR PUMP INCLUDED

- PVC 2" Delivery Pipe

14

- PVC 2" 90 Bend

12

- Plug
with built in thermal protection and manual/automatic
switch.

10

40 0
/12

300

Electric Pump Motor


- Dry motor
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Level of protection IP68
- Class F insulation
- Speed of rotation 2850 rpm
- Completely insulated cable connection chamber
Usage Limitations
- Type of liquid: sewage water, with suspended solids
of a maximum dimension of 40 mm
- Maximum liquid temperature 50C

/10

20

0/8

4
2
Hm
Q

50
3

L / 1'
m3/ h

100
6

200
12

150
9

250
15

300
18

350
21

400
24

450
27

Accessories (only on request)


- Screw-down tank extension
(see page 209)
- Threaded ball check valve 2" F
(see page 208)
- Ball valve with threaded full bore 2" F
(see page 208)
- Overflow float
(see page 210)

N2141030
N2141040
N2141050

MODEL

Nominal
Power

Absorbed
Power

VOLTAGE

Amp.

F.

L/1'

kW

HP

kW

VS 170-B 200 I

0,8

0,6

1,2

0,9

1 ~ 220 240 V

4,1

12,5

VS 170-B 300

1,2

0,9

1,7

1,3

1 ~ 220 240 V

5,8

20

VS 170-B 400

1,6

1,2

2,2

1,6

1 ~ 220 240 V

7,2

20

218

100 150 200 250 300 350 400


PRICE

m /h

HP

50

Discharge Head
in meters

CODE

12

15

18

21

7,8

6,3

4,6

0,5

9,8

8,7

7,5

6,3

4,7

0,5

11,2 10,4 9,3

8,3

7,1

5,8

4,2

24

2,5

AUTOMATIC PUMPING STATION


MINI COLLECTION AND PUMPING
STATIONS FOR WASTE WATER
The VACUSYSTEM 170Ss are pre-assembled, readyfor-use automatic pumping stations, designed for the
disposal of waste and sewage water.
Particularly suitable when the water from drains is
collected at a lower level than the main sewer.
Design Features
- The standard pumping station consists of:
- Tank
In polyethylene with a capacity of 170 litres with screwdown lid.
Three possible types of water collection or ventilation
pipe inlet and cable glands for the electric pump power
supply cable and service cables (overflow float on
request).
- BIOX Submersible Pump
Models 300/10 and 400/12 single phase version with
float or three phase; with cast steel impellers.
- Stainless Steel Connecting Foot

CONNECTING GUIDE, MOTOR PUMP INCLUDED


14
12

- 2" Delivery Pipe


- 2" 90 Bend
- Plug
with built in thermal protection and manual/automatic
switch.

10

40 0
/12

300

- Electric panel for the control and protection of three


phase electric pumps.

- Float with 10 m of 3 x 1 HO7 RN-F cable (for three


phase pumps)

Electric Pump Motor


- Dry motor
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding; three phase with external
protection
- Level of protection IP68
- Class F insulation
- Speed of rotation 2850 rpm
- Completely insulated cable connection chamber

/10

Hm
Q

50
3

L / 1'
m3/ h

100
6

200
12

150
9

250
15

300
18

350
21

400
24

450
27

Usage Limitations
- Type of liquid: sewage water, with suspended solids
of a maximum dimension of 40 mm.
- Maximum liquid temperature 50C
Accessories (only on request)
- Screw-down tank extension
(see page 209)
- Threaded ball check valve 2" F
(see page 208)
- Ball valve with threaded full bore 2" F
(see page 208)
- Overflow float
(see page 210)

MODEL

Nominal
Power

Absorbed
Power

HP

kW

HP

kW

VOLTAGE

Amp.

F.

L/1'
3

m /h

N2141060

VS 170 S-B 300 M

1,2

0,9

1,7

1,3

1 ~ 220 240 V

5,8

N2141070

VS 170 S-B 300 T

1,2

0,9

1,7

1,3

3 ~ 400 V

2,2

N2141080

VS 170 S-B 400 M

1,6

1,2

2,2

1,6

1 ~ 220 240 V

7,2

N2141090

VS 170 S-B 400 T

1,6

1,2

2,2

1,6

3 ~ 400 V

2,5

219

20

20

50

100 150 200 250 300 350 400

Discharge Head
in meters

CODE

PRICE
3

9,8
9,8

12

15

18

21

24

8,7 7,5

6,3

4,7

0,5

8,7 7,5

6,3

4,7

0,5

11,2 10,4 9,3

8,3

7,1

5,8

4,2

2,5

11,2 10,4 9,3

8,3

7,1

5,8

4,2

2,5

VACUSYSTEM
MINI COLLECTION AND PUMPING
STATIONS FOR WASTE WATER
The VACUSYSTEM 400 TWINs are pre-assembled,
ready-for-use automatic pumping stations, designed
for the disposal of waste and sewage water.
Particularly suitable when the water from drains is
collected at a lower level than the main sewer.
Design Features
- The standard pumping station consists of:
- Tank
In polyethylene with a capacity of 400 litres with screwdown lid.
Three possible types of water collection or ventilation
pipe inlet and cable glands for the electric pump power
supply cable and service cables (overflow float on
request)
- Pair of BIOX Submersible Pumps
Models 300/10 and 400/12 with cast steel impellers.
- Two Stainless Steel Connecting Foot

DOUBLE CONNECTING GUIDE, MOTOR PUMPS AND SINGLE


CONTROL BOX INCLUDED
14
12

- Two 2" Delivery Pipes

10

40 0
/12

- Electric panel for the control and protection of three


phase electric pumps, with metal body, general switch,
electronic keyboard, pump start/stop control LEDs,
remote alarm activation and alternation on pump
starting.

300

- Two floats with 10 m of 3 x 1 HO7 RN-F cable

- Two 2" 90 Bends

Electric Pump Motor


- Dry motor
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding; three phase with external
protection
- Level of protection IP68
- Class F insulation
- Speed of rotation 2850 rpm
- Completely insulated cable connection chamber

/10

2
Hm
Q

50
3

L / 1'
m3/ h

100
6

200
12

150
9

300
18

250
15

350
21

400
24

450
27

Usage Limitations
- Type of liquid: sewage water, with suspended solids
of a maximum dimension of 40 mm.
- Maximum liquid temperature 50C
Accessories (only on request)
- Screw-down tank extension
(see page 209)
- Threaded ball check valve 2" F
(see page 208)
- Ball valve with threaded full bore 2" F
(see page 208)
- Overflow float
(see page 210)

MODEL

Nominal
Power

Absorbed
Power

HP

kW

HP

kW

VOLTAGE

Amp.

F.

L/1'
3

m /h

N2141100

VS 400 TWIN-B 300 M

1,2

0,9

1,7

1,3 1 ~ 220 240 V

5,8

N2141110

VS 400 TWIN-B 300 T

1,2

0,9

1,7

1,3

2,2

N2141120

VS 400 TWIN-B 400 M

1,6

1,2

2,2

1,6 1 ~ 220 240 V

7,2

N2141130

VS 400 TWIN-B 400 T

1,6

1,2

2,2

1,6

2,5

3 ~ 400 V

3 ~ 400 V

220

20

20

50

100 150 200 250 300 350 400

Discharge Head
in meters

CODE

PRICE
3

12

15

18

21

9,8

8,7

7,5 6,3

4,7

0,5

9,8

8,7

7,5 6,3

4,7

0,5

24

11,2 10,4 9,3

8,3 7,1

5,8

4,2

2,5

11,2 10,4 9,3

8,3 7,1

5,8

4,2

2,5

GENERAL CONDITIONS OF SALE


ORDERS
Orders sent to our agents become valid only if approved by our Sales Department.
PRICES
The prices are understood as net of taxes and may be modified without prior notice, due to the general trend in costs or other causes.
DELIVERY
Delays due to force majeure, or any other reason, do not justify the cancellation of the order, nor may any compensation be requested. Partial
deliveries, i.e. performed at different successive stages, are also authorised. The delivery date of the supply is never to be considered final or
essential.
SHIPMENT
The goods are carried at the risk of the buyer even when sent carriage free. In the case of a dispute, the buyer must immediately inform the
carrier of the event by registered mail with a copy to us. However, once eight days have lapsed from receipt of the goods, claims are no longer
permitted.
PAYMENTS
Our invoices are payable in cash or in accordance with the methods established and accepted when ordering. Any delay or irregularity in
payments as well as any irregularity in performing the contract on the part of the buyer constitute non-fulfilment with resultant default action,
authorising the seller to issue a sight draft for the sum due to him without prejudice to any other or greater action by him. Any contract expenses,
registration fees, stamp duty, invoicing, receipt etc. expenses are to the account of the buyer in the case of non-payment.
PROPERTY TO THE MATERIAL
Our right of property in the material delivered is valid until full payment of the corresponding invoice has been made. An unjustified delay in
the payment agreed gives us the right to exact immediate return, carriage free of the material delivered, even if partial delivery has been made.
The BUYER will be immediately declared as forfeiting the benefit of the term and bank interest will be to his account.
MODIFICATIONS
STA-RITE S.p.A. reserves the right to carry out modifications to its products at any time without having to provide prior notice.
RETURNS
Goods retur ns are not accepted for any reason unless otherwise authorised by letter

by

STA-RITE

S.p.A.

SUPPLIES
Agreements or promises that are different from the normal conditions of supply are not recognised unless signed in the purchase order and
duly approved by STA-RITE S.p.A.
GUARANTEE
This device is covered by legal warrantee according to the laws and norms in force on the date and in the country of purchase, relatively to
flaws and defects in manifacturing and/or materials used. Our guarantee is limited to the replacement or repair, in our workshop and by us, of
the pump or part that is identified as being faulty. In no case however does the guarantee involve the possibility of requesting compensation.
Breakdowns caused by errors in electrical connection, by a lack of adequate protection, by defective assembly, by incorrect action or by a lack
of care in producing the equipment are excluded from the guarantee:
- breakdowns caused to the materials due to corrosion or abrasions of any type and nature caused by the pumped liquid:
- incorrect operation due to installations not performed in a perfectly workmanlike manner;
- where the Customer is not up-to-date with payments.
In particular our guarantee is void where our submersed or submersible pumps (three phase or single phase) have not been installed with the
control and protection equipment specified by us. In the absence of documentation proving the date of shipment, the age of the pump will be
determined from the code given in the identification plate. Finally material removed, repaired or tampered with by any person not expressly
authorised by us to do so is excluded from our guarantee.
The faulty material must be returned to our workshops carriage free and, once it is identified that the fault comes under our responsibility, it
will in turn be returned carriage free.
TESTS
Tests are undertaken at our workshops in the presence of the customer if this is required. The curves are considered valid for the rotation speeds
given in the tables: tolerance according to ISO 2548 standards - C. Head and NPSH values valid for water with a specific weight of 1 kg/dm3
at 20 C.
DISPUTES
There may be no exception to the conditions stated above unless expressed and accepted in writing. The resolution of any dispute falls within
the jurisdiction of the Court of Pisa, even if the payment is agreed by means of a draft.
This Catalogue replaces and cancels all previous ones

Technical data subject to change without notice.

BENELUX

STA RITE BENELUX


Tel. / Fax + 31(0)13 631 633 / 4
Saal van Zwanembergweg, 11
5026 RM Tilburg
The Netherlands
e-mail: sta-rite@remmersretailservice.com

Potrebbero piacerti anche