catalogue
INDEX
SURFACE PUMPS
EP.....................................................................4
CM....................................................................5
CB.....................................................................6
CM DIN 24255 .................................................7
JETINOX ........................................................14
NEW JET........................................................16
JET .................................................................17
AP...................................................................19
MCX ...............................................................20
DHR................................................................23
DHI .................................................................25
MAX ...............................................................27
MULTINOX-A VE ...........................................29
VLR - VLRI - VLRX ........................................31
VLR ACESSORIES ........................................63
R2CD R4CD...................................................85
R2T R4T .........................................................95
R2TD R4TD..................................................105
A2L A4L .......................................................115
A2LD A4LD....................................................121
CIRCULATION PUMP ACCESSORIES........128
PRESSURE ASSEMBLIES
SIZING HOME WATER SYSTEMS .............195
WATERPRESS SUPERINOX.......................204
WATERPRESS .............................................198
WATERPRESS INOX ...................................200
ACCESSORIES
HYDRAULIC ................................................207
ELECTRICAL ...............................................210
CONTYROL PANELS ..................................211
A2L A4L........................................................115
A2LD A4LD...................................................121
ACCESSORIES CIRCULATION PUMPS . 128
ACCESSORIES ELECTRICAL ..................210
ACCESSORIES HYDRAULIC ...................207
ACCESSORIES PGA - DELTA OIL ...........191
ACCESSORIES VERSAILLES ...................193
ACCESSORIES VITEX ..............................166
ACCESSORIES VLR ....................................63
OMNIA .........................................................133
PRIOX ..........................................................135
PGA - DELTA OIL ........................................191
PRATIKA ......................................................168
PIPE FRICTION LOSS CHARTS.................197
SA 6 ............................................................184
SCM 4 PLUS................................................172
SOM .............................................................134
SOMVORT ...................................................138
SR3.................................................................65
SIZING HOME
WATER SYSTEMS.......................................195
SCM 4 PLUS PUMP-ENDS.........................181
4" SUBMERSIBLE MOTORS......................183
VACUSYSTEM.............................................217
VERSAILLES................................................192
VITEX OM ....................................................159
VITEX SB .....................................................139
VITEX SP......................................................149
VLR.................................................................31
VLRI................................................................43
VLRX ..............................................................51
WATERPRESS ............................................198
WATERPRESS INOX...................................200
WATERPRESS INOX 50L............................202
WATERPRESS - SUPERINOX ....................204
AP...................................................................19
DHI ................................................................25
DHR ...............................................................23
DOMINATOR 4"...........................................169
DOMINATOR 5"...........................................170
DRENOX ......................................................132
EP.....................................................................4
JET .................................................................17
JETINOX ........................................................14
MAX ...............................................................27
MCX ...............................................................20
MINIVORT P ................................................136
MINIVORT PP ..............................................137
MULTINOX - A - VE.......................................29
NEWJET.........................................................16
SURFACE PUMPS
50 Hz
EP
SURFACE PUMPS
PERIPHERAL PUMPS
The EP series peripheral monobloc pumps are
especially suitable where high heads with limited
flow rates need to be developed.
Design Features
-Cast iron pump casing
-Cast iron motor bracket
-Brass impeller
-Stainless steel shaft
-Graphite mechanical seal with ceramic
counterface
Motor
-Enclosed, externally ventilated
-Level of protection IP 44
-Class F insulation
-Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
-Three phase power supply with external
protection provided by the user
-Speed of rotation 2850 rpm
-Suitable for continuous use
70
60
50
40
Usage Limitations
-Type of liquid: clean water with no suspended
solids or abrasive material
-Maximum liquid temperature 70C
-Maximum recommended suction height 5 m
with foot valve
-Maximum operating pressure 6.5 bar
30
20
10
Applications
-Small-scale booster systems
-Domestic autoclaves
-Small-scale irrigation
-Washing systems
Hm
Q
30
1,8
20
1,2
10
0,6
L / 1'
m3/ h
50
3
40
2,4
60
3,6
70
4,2
Dimensions mm.
Model
A
80
4,8
Weight
DNA
DNM
kg
EP2
260
85
100
145
135
1"
1"
6,8
EP4
295
90
112
156
150
1"
1"
11
MODEL
Nominal Absorbed
Power
Power
HP
kW
HP
VOLTAGE
Amp.
L/1'
10
20
30
40
50
60
0,3
0,6
1,2
1,8
2,4
3,6
42
37
27
17
59
55
46
37
28
19
Q
m /h
kW
N4162010
N4162020
EP2 M
EP2 T
2,9
1,6-0,9
N4164010
N4164020
EP4 M
EP4 T
1 ~ 220240 V
3 ~ 230400 V
5
3,8-2,2
16
Discharge head
in meters
CODE
PRICE
CM
SURFACE PUMPS
HORIZONTAL SINGLE-STAGE
CENTRIFUGAL PUMPS
The CM series single impeller centrifugal pumps
are silent and have a high hydraulic efficiency.
Design Features
- Cast iron pump casing
- Cast iron motor bracket
- Brass impeller (model CM 90/22 in
technopolymer)
- Stainless steel shaft
- Graphite mechanical seal with ceramic
counterface
- Stainless steel seal holder plate
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
70
60
50
130/51
110/44
10 0 / 3 6
40
30
Usage Limitations
- Type of liquid: non-abrasive clear or slightly
cloudy water
- M a x i m u m l i q u i d t e m p e r a t u re 9 0 C
(model CM 90/22 50C)
- Maximum recommended suction height 5 m
with foot valve
- Maximum operating pressure:
6 bar for models HP 0.5 - 0.75
8 bar for models HP 1 - 1.5 - 2
9 0/ 2 2
20
10
Hm
Q
60
40
20
L / 1'
m3/ h
100
6
80
4
120
140
8
160
Applications
- Pumping from wells for irrigation
- Booster systems
- Domestic autoclaves
- Washing systems
Dimensions mm.
Model
A
Weight
75
43
267
150
110
160
82
202
CM 100/36
82
44
310
180
140
185
97
232
CM 110/44
88
45
350
194
155
200
100
252
CM 130/51
88
45
350
220
180
225
115
286
MODEL
Nominal Absorbed
Power
Power
VOLTAGE
Amp. F
0,75
1 ~ 220240 V
3 ~ 230400 V
3,6
2,4-1,4
12,5
CM 100/36 M
CM 100/36 T
1 ~ 220240 V
3 ~ 230400 V
5,5
3,8-2,2
20
N4187090
N4187100
CM 110/44 M
CM 110/44 T
1 ~ 230 V
3 ~ 230400 V
9,2
6,1-3,3
35
N4187110
N4187120
CM 130/51 M
CM 130/51 T
1 ~ 230 V
3 ~ 230400 V
10,8
7,8-4,5
40
CM 90/22 M*
CM 90/22 T*
N418B130
N418B140
0,5 0,35 1
10
30
50
80
100
120
0,6
1,8
3,0
4,8
7,2
22
20
18
13
35
33
31
26
22
42
40
38
33
29
51
50
48
44
40
m /h
HP KW HP KW
N418B090
N418B100
L/1'
Q
* TECHNOPOLYMER IMPELLER
5
Discharge head
in meters
CODE
DNA
CM 90/22
34
DNM
kg
1"
1"
6,5
1"
1"
11
1"1/4
1"
20,5
1"1/4
1"
23
PRICE
CB
SURFACE PUMPS
TWIN IMPELLER
CENTRIFUGAL PUMPS
The model CB Twin impeller centrifugal electric
pumps have two self balanced impellers to give
very high efficiency.
Design Features
- Cast iron pump casing
- Cast iron motor bracket
- Die cast aluminium support with stainless
steel back plate to hidraulic side (cast iron
only on models 1,5-2-3 HP)
- Noryl GFN2 impeller ( stamped brass impeller
on model 1,5-2-3 HP)
- Stainless steel motor shaft
- Graphite mechanical seal with ceramic
counterface
80
70
Motor
- Totally enclosed fan cooled motor to IP44
protection
- F class winding
- Stamped fan cover
- For singlephase models built in thermal
protector and permanently connected
capacitor
60
160/6
8
/65
120
50
110/
55
80/38 90/44
40
30
Usage Limitations
- Suction depth 5 mt.
- Max water temp.:
40 C for models 0,75-1 HP
90 C for models 1,5-2-3 HP
- Max pressure:
6 Bar 0,75-1 HP
10 Bar 1,5-2-3 HP
20
10
Hm
Q
L / 1'
m3/ h
20
1,2
40
2,4
60
3,6
80
4,8
100
6,0
120
7,2
160
9,6
140
8,4
180
10,8
Applications
- Domestic and industrial uses
- Booster systems
- Pumping from wells for irrigation
- Washing system
Dimensions mm.
Model
Weight
DNA
DNM
CB 80/38
66
73
346
180
140
180
97
227
1"
1"
14,3
CB 90/44
66
73
346
180
140
180
97
227
1"
1"
15,6
CB 110/55
CB 120/65
CB 160/68
74
74
74
86
86
86
400
400
400
195
195
195
155
155
155
214
214
214
110
110
110
265
265
265
1"1/4
1"1/4
1"1/4
1"
1"
1"
25,7
26
26,5
N4189010
N4189020
Nominal
Power
MODEL
CB 80/38 M *
CB 80/38 T *
Absorbed
Power
VOLTAGE
Amp.
F.
L/1'
kW
HP
kW
0,75
0,55
1,1
0,8
1 ~ 220 V
3 ~ 220380 V
4,4
2,6-1,5
1,6
5,5
3,8-2,2
20
N4189030
N4189040
CB 90/44 M *
CB 90/44 T *
0,74
1,6
1,2
1 ~ 220 V
3 ~ 220380 V
N4189050
N4189060
CB 110/55 M
CB 110/55 T
1,5
1,1
2,5
1,8
1 ~ 220 V
3 ~ 220380 V
8,5
6 -3,4
31,5
N4189070
N4189080
CB 120/65 M
CB 120/65 T
1,5
3,1
2,3
1 ~ 220 V
3 ~ 220380 V
10,5
7,3-4,2
31,5
N4189090
CB 160/68 T
2,2
3,8
2,8
3 ~ 220380 V
8,2-4,7
* TECHNOPOLYMER IMPELLER
6
20
40
60
80
100
120
140
160
1,2
2,4
3,6
4,8
7,2
8,4
9,6
35
31
26
18
40
37
31,5
24,5
54,5
51
46
39
30
64
60
55
49
41
32
67
64,5
61
57
52
46
39
32
kg
PRICE
3
m /h
HP
Altezza
manometrica
in m.c.a.
CODE
SURFACE PUMPS
USAGE LIMITATIONS
Type of liquid: non-aggressive, non-explosive,
free from solid particles and fibres.
- Hot water for heating
- Coolants (not containing mineral oils) for airconditioning systems
- Pumped liquid temperature from -10 C to 90C
- Environmental temperature up to 40 C
- Maximum operating pressure 10 bar
MOTOR
- Type: induction, enclosed, self-ventilated
- Design: B5
- Use: continuous
- Insulation: Class F
- Level of protection: IP 55 Terminal Box
IP 44 complete motor
- Number of poles: 2
- Speed of rotation 2900 rpm
APPLICATIONS
- Agricultural: overhead or surface irrigation
water supply
- Civil: autoclave supply, pressure elevation,
heating and air-conditioning systems, water
supply and firefighting systems
- Industrial: liquid transfer in general
CM DIN 24255
DN
32
40
50
65
80
100
DIMENSIONS (mm)
Holes
D
K
n
Dia.
140
100
4
18
150
110
4
18
165
125
4
18
185
145
4
18
200
160
4
18
220
180
8
18
Dimensions mm
Weight
kg
Model
DNM
CM 32/160
CM 32/200
CM 32/250
CM 40/125
CM 40/160
CM 40/200
CM 40/250
CM 50/125
CM 50/160
CM 50/200
CM 50/250
CM 65/125
CM 65/160
CM 65/200
CM 65/250
CM 80/160
CM 80/200
C
B
A
C
B
A
C
B
A
C
B
A
B
A
B
A
B
A
B
A
B
A
C
B
A
C
B
A
B
A
C
B
A
C
B
A
B
A
D
C
B
A
B
A
DNA
H1
H2
132
160
100
80
32
50
100
M1
160
180
180
225
112
140
132
160
160
180
180
225
132
160
150
180
M2
70
N1
240
N2
190
50
65
125
95
320
250
210
160
240
190
265
212
320
250
240
190
65
65
100
100
70
125
100
95
70
490
240
292
268
340
305
405
495
220
252
500
245
292
590
273
340
630
700
322
405
525
250
292
590
270
340
505
565
625
14
695
50
14
15
65
50
265
160
12
12
100
50
14
80
40
12
212
14
200
635
290
360
332
405
705
180
225
125
95
320
250
65
14
750
180
605
280
160
200
65
80
125
95
100
635
65
14
14
100
125
340
290
360
330
405
370
450
705
180
225
200
250
160
120
320
250
360
280
320
80
212
280
180
225
125
80
250
16
345
280
19
14
16
850
665
735
14
65
95
750
330
780
870
405
355
38
39
42
52
63
69
83
90
120
36
37
40
47
50
65
71
91
121
47
50
65
71
82
89
122
125
140
149
64
70
84
90
120
122
138
148
239
253
99
129
143
152
233
247
CM 32
SURFACE PUMPS
20
100
90
80
15
30
40
20
30
50
100
40
50
Q (US. GPM)
100
200
300
Q (IMP. GPM)
200
400
300
500
400
750
500
1000
750
300
250 A
250
70
250 B
60
200
250 C
50
150
40
200 A
30
100
200 B
200 C
75
20
160 A
50
H (m)
160 C
160 B
40
10
H (ft)
10
9
8
7
6
5
30
250
0B A
16 160
200
25
20
15
C
160
3
NPSH
(m)
2
10
NPSH
(ft)
5
5
75
CODE
100
MODEL
9 10
150
15
200
300
Motor
Power
Q (m3h) 30
20
Q (l/min) 500
VOLTAGE
HP
kW
Amp.
3 X 400 V
D5732KKK
CM 32/160 C
1,5
3 ~ 230 400 V
D5733KKK
CM 32/160 B
2,2
3 ~ 230 400 V
5,2
D5734KKK
CM 32/160 A
3 ~ 230 400 V
7,1
D5735KKK
CM 32/200 C
5,5
3 ~ 230 400 V
9,4
D5736KKK
CM 32/200 B
5,5
3 ~ 230 400 V
14,2
7,5
D5737KKK
CM 32/200 B
D5738KKK
CM 32/200 A
10
7,5
3 ~ 400 690 V
3 ~ 230 400 V
16,5
40
50
60
750
70 80 90 100
1000
L/1'
1500
150
2000
200
3000
PRICE
3
m /h
24,7 24,1
9
23
12
18
24
30
36
37
28,7
21,5 17,2
41
40
53
52
51
50
26
30
46,8 42,7
3 ~ 400 690 V
D5739KKK
CM 32/200 A
D5740KKK
CM 32/250 C
12,5
9,2
3 ~ 400 690 V
20,1
70
D5741KKK
CM 32/250 B
15
11
3 ~ 400 690 V
24,2
82
D5742KKK
CM 32/250 A
20
15
3 ~ 400 690 V
30,1
93
250
4000
Discharge head
in meters
68
67
80,5 79,5
92
77
72,6 66,5
80
CM 40
SURFACE PUMPS
20
100
90
80
15
30
20
40
30
50
100
40
50
Q (US. GPM)
100
200
300
Q (IMP. GPM)
200
400
300
500
400
750
500
1000
750
300
250
250 A
70
200
60
250 B
50
150
200 A
40
200 B
30
100
160 A
75
160 B
20
125 A
50
H (m)
40
125 B
125 C
10
H (ft)
10
9
8
7
6
5
30
00
25
5
12
20
15
16
25
10
3
NPSH
(m)
2
NPSH
(ft)
5
1
4
5
75
CODE
100
9 10
150
MODEL
15
200
300
Motor
Power
Q (m3h) 30
20
Q (l/min) 500
VOLTAGE
HP
kW
Amp.
3 x 400 V
40
50
750
60
70 80 90 100
1000
L/1'
Q
m /h
1500
150
2000
12
24
30
36
42
CM 40/125 C
1,5
3 ~ 230 400 V
D5771KKK
CM 40/125 B
2,2
3 ~ 230 400 V
5,2
D5772KKK
CM 40/125 A
3 ~ 230 400 V
7,1
D5744KKK
CM 40/160 B
3 ~ 230 400 V
7,4
D5745KKK
CM 40/160 A
5,5
3 ~ 230 400 V
9,9
D5746KKK
CM 40/200 B
7,5
5,5
3 ~ 400 690 V
13,2
D5751KKK
CM 40/200 A
10
7,5
3 ~ 400 690 V
16,8
56,4 58
D5749KKK
CM 40/250 B
15
11
3 ~ 400 690 V
24,2
56
D5750KKK
CM 40/250 A
20
15
3 ~ 400 690 V
32
76
30
Discharge head
in meters
250
4000
PRICE
18
D5770KKK
10
200
3000
30
35,4 35,5
21
29
27,1 24,4
35
57,6
56
53
84
48,9 43,9
80,5
CM 50
SURFACE PUMPS
20
100
90
80
15
30
20
40
30
50
100
40
50
Q (US. GPM)
100
200
300
Q (IMP. GPM)
400
200
300
500
400
750
500
1000
750
300
250
250 A
70
200
60
250 B
50
40
250 C
200 A
30
200 B
150
100
160 A
200 C
20
75
160 B
125 A
H (m)
50
40
10
H (ft)
125 B
10
9
8
7
6
5
30
25
20
15
160
10
3
NPSH
(m)
2
NPSH
(ft)
5
1
4
5
75
CODE
100
9 10
15
150
200
300
Motor
Power
MODEL
HP
kW
Q (m3h) 30
20
Q (l/min) 500
VOLTAGE
Amp.
3 x 400 V
40
50
60
750
70 80 90 100
1000
L/1'
150
1500
2000
21
30
20
250
4000
PRICE
3
m /h
39
48
60
72
14
11,2
CM 50/125 B
3 ~ 230 400 V
7,4
19,9
D5774KKK
CM 50/125 A
5,5
3 ~ 230 400 V
9,9
D5753KKK
CM 50/160 B
7,5
5,5
3 ~ 400 690 V
11,6
D5755KKK
CM 50/160 A
10
7,5
3 ~ 400 690 V
15,8
36,3 37
D5775KKK
CM 50/200 C
12,5
9,2
3 ~ 400 690 V
18,5
D5756KKK
CM 50/200 B
15
11
3 ~ 400 690 V
21
D5757KKK
CM 50/200 A
20
15
3 ~ 400 690 V
27
58,5
D5758KKK
CM 50/250 C
20
15
3 ~ 400 690 V
32,5
71,5
70,3 68,3
D5759KKK
CM 50/250 B
25
18,5
3 ~ 400 690 V
41,5
78
D5760KKK
CM 50/250 A
30
22
3 ~ 400 690 V
51,5
90
Discharge head
in meters
D5773KKK
11
200
3000
36,6 35,6
47
44,5
52
50
42
34
31
26,9
38,5
33
24,5
66
32
49
42,8
61,5
55
CM 65
SURFACE PUMPS
20
100
90
80
15
30
20
40
30
50
100
40
50
Q (US. GPM)
100
200
300
Q (IMP. GPM)
400
200
500
300
750
400
1000
500
750
300
250
70
60
250 A
50
250 B
200
150
200 A
40
200 B
200 C
30
100
160 A
75
160 B
125 A
20
160 C
50
H (m)
125 B
40
10
H (ft)
10
9
8
7
6
5
125
30
250
25
160
20
200
15
4
10
3
NPSH
(m)
2
NPSH
(ft)
5
1
4
5
75
CODE
100
MODEL
9 10
150
15
200
20
300
Motor
Power
Q (m3h) 30
Q (l/min) 500
VOLTAGE
HP
kW
Amp.
3 x 400 V
40
50
750
60
70 80 90 100
1000
1500
150
200
2000
3000
L/1'
m3/h
54
PRICE
72
84
144
CM 65/125 B
7,5
5,5
3 ~ 400 690 V
12,3
D5777KKK
CM 65/125 A
10
7,5
3 ~ 400 690 V
15,9
D5761KKK
CM 65/160 C
12,5
3 ~ 400 690 V
19,5
D5762KKK
CM 65/160 B
15
11
3 ~ 400 690 V
22,5
34
D5763KKK
CM 65/160 A
20
15
3 ~ 400 690 V
30
39
D5764KKK
CM 65/200 C
20
15
3 ~ 400 690 V
32,5
43
D5765KKK
CM 65/200 B
25
18,5
3 ~ 400 690 V
41,5
D5766KKK
CM 65/200 A
30
22
3 ~ 400 690 V
51,5
D5778KKK
CM 65/250 B
40
30
3 ~ 400 690 V
63,5
81 79,5
76
73
65
D5779KKK
CM 65/250 A
50
37
3 ~ 400 690 V
74,5
90 89,5 86,5
84
76,5
Discharge head
in meters
D5776KKK
12
250
4000
38 35,3
41
60
15
32
38
44
54,5 48,5
72 66,5 60,5
CM 80
SURFACE PUMPS
20
100
90
80
15
30
20
40
30
50
100
40
50
Q (US. GPM)
100
200
300
Q (IMP. GPM)
200
400
500
300
400
750
500
1000
750
300
250
70
60
200 A
50
200 B
200
150
40
160 A
160 B
160 C
30
100
160 D
75
20
50
H (m)
40
H (ft)
10
10
9
8
7
6
5
30
25
20
160
200
15
4
10
3
NPSH
(m)
2
NPSH
(ft)
5
1
4
5
75
CODE
100
9 10
150
MODEL
15
200
20
300
Motor
Power
HP
kW
Q (m3h) 30
40
Q (l/min) 500
VOLTAGE
50
60
750
Amp.
3 x 400 V
70 80 90 100
1000
L/1'
1500
150
2000
250
4000
Q
3
m /h
72
96
CM 80/160 D
15
11
3 ~ 400 690 V
20,8
24
D5781KKK
CM 80/160 C
20
15
3 ~ 400 690 V
25,8
29
D5782KKK
CM 80/160 B
25
18,5
3 ~ 400 690 V
35
D5783KKK
CM 80/160 A
30
22
3 ~ 400 690 V
42
D5786KKK
CM 80/200 B
40
30
3 ~ 400 690 V
D5787KKK
CM 80/200 A
50
37
3 ~ 400 690 V
Discharge head
in meters
D5780KKK
13
200
3000
31
22
18,7
27,7
25
20,3
37
63,5
49
74,5
58
JETINOX
SURFACE PUMPS
SELF-PRIMING STAINLESS STEEL
JET PUMPS
The JETINOX self-priming pumps combine the
functional benefits of centrifugal pumps and
the practical benefits of self-priming pumps.
The Venturi system the pumps are fitted with
guarantees optimum hydraulic efficiency and
considerable pressure capacity.
Design Features
- Pump casing in AISI 304 stainless steel
- Motor bracket in die-cast aluminium
- Technopolymer impeller with stainless steel
shim ring
- Monobloc technopolymer diffusor-Venturi
tube-nozzle assembly
- Stainless steel shaft
- Graphite mechanical seal with ceramic
counterface
- Technopolymer seal holder plate
48
40
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use
32
70
/50
24
45
60/
/43
50
16
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 8 m
with foot valve
- Maximum operating pressure 6 bar
8
Hm
Q
30
1,8
20
1,2
10
0,6
L / 1'
m3/ h
50
3
40
2,4
60
3,6
70
4,2
80
4,8
Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Washing systems, garden irrigation, fountains
Dimensions mm.
Model
A
Weight
E
DNA
DNM
kg
351
93
140
190
178
1" F
1" F
4,7
374
93
140
190
178
1" F
1" F
8,2
JETINOX 70/50
351
76
144
196
180
1"F
1" F
9,5
CODE
MODEL
Nominal Absorbed
Power
Power
HP
kW HP
VOLTAGE
Amp.
kW
N4176190
N4176570
12,5
N4176760
4,5
16
L/1'
10
20
30
40
50
60
70
m /h
0,6
1,2
1,8
2,4
3,6
4,2
Discharge head
in meters
JETINOX 45/43
JETINOX 60/50
43
30
23
16
46
36
31
26
18
48
43
37
32
25
16
14
PRICE
JETINOX
SURFACE PUMPS
SELF-PRIMING STAINLESS STEEL
JET PUMPS
The JETINOX series self-priming pumps
combine the functional benefits of centrifugal
pumps and the practical benefits of self-priming
pumps.
The Venturi system the pumps are fitted with
guarantees optimum hydraulic efficiency and
considerable pressure capacity.
Design Features
- Pump casing in AISI 304 stainless steel
- Motor bracket in die-cast aluminium
- Technopolymer impeller with stainless steel
shim ring
- Monobloc technopolymer diffusor-Venturi
tube-nozzle assembly
- Stainless steel shaft
- Graphite mechanical seal with ceramic
counterface
- Stainless steel seal holder plate
60
50
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use
40
90/50
30
90/43
20
10
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 8 m
with foot valve
- Maximum operating pressure 6 bar
Hm
Q
45
2,7
30
1,8
15
0,9
L / 1'
m3/ h
75
4,5
60
3,6
90
5,4
105
6,3
Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Washing systems, garden irrigation, fountains
Dimensions mm.
Model
Weight
DNA
DNM
kg
JETINOX 90/43
397
98
168
220
235
1 1 /4 " M
1" F
11
JETINOX 90/50
430
98
168
260
235
1 1 /4 " M
1" F
13
MODEL
Nominal Absorbed
Power
Power
HP
kW HP
JETINOX 90/43 M
N4176500
Amp.
1,5 1 ~ 220240 V
L/1'
10
20
30
40
50
60
80
0,6
1,2
1,8
2,4
3,6
4,8
43
38
34
32
29
27
25
10
50
42
39
37
33
30
27
20
Q
m /h
kW
N4176280
VOLTAGE
6,5
20
25
Discharge head
in meters
CODE
15
PRICE
NEW JET
SURFACE PUMPS
SELF-PRIMING CAST IRON
JET PUMPS
The NEWJET series self-priming pumps
combine the functional benefits of centrifugal
pumps and the practical benefits of self-priming
pumps.
The Venturi system the pumps are fitted with
guarantees optimum hydraulic efficiency and
considerable pressure capacity.
Design Features
- Cast iron pump casing
- Motor bracket in die-cast-aluminium
- Technopolymer impeller with stainless steel
shim ring
- Monobloc technopolymer diffusor-Venturi
tube-nozzle assembly
- Stainless steel shaft
- Graphite mechanical seal with ceramic
counterface
48
40
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use
32
24
45
60/
/43
50
16
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 8 m
with foot valve
- Maximum operating pressure 6 bar
8
Hm
Q
30
1,8
20
1,2
10
0,6
L / 1'
m3/ h
50
3
40
2,4
60
3,6
80
4,8
70
4,2
Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Washing systems, garden irrigation, fountains
Dimensions mm.
Model
Weight
DNA
DNM
kg
NEWJET 45/43
351
93
130
180
174
1"
1"
8,2
NEWJET 60/50
351
93
130
180
174
1"
1"
CODE
MODEL
Nominal
Power
Absorbed
Power
HP
kW
HP
kW
L/1'
VOLTAGE
Amp.
F.
N4176050
NEWJET 45/43 M
0,5
0,37
0,8
0,6
1 ~ 220 240 V
N4176580
NEWJET 60/50 M
0,75
0,55
1,1
0,8
1 ~ 220 240 V
12,5
16
10
20
30
40
50
60
0,6
1,2
1,8
2,4
3,6
43
30
23
16
46
36
31
26
18
Q
3
m /h
Discharge
head
in meters
PRICE
SURFACE PUMPS
SELF-PRIMING CAST IRON
JET PUMPS
The JET series self-priming pumps combine
the functional benefits of centrifugal pumps and
the practical benefits of self-priming pumps.
The Venturi system the pumps are fitted with
guarantees optimum hydraulic efficiency and
considerable pressure capacity.
Design Features
- Cast iron pump casing
- Cast iron motor bracket
- Technopolymer impeller, Venturi tube and
nozzle
- Diffusor, with stainless steel shim ring
- Stainless steel shaft
- Graphite mechanical seal with ceramic
counterface
50
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
40
30
100
00
60
20
10
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 8 m
with foot valve
- Maximum operating pressure 6 bar
Hm
Q
30
1,8
20
1,2
10
0,6
L / 1'
m3/ h
50
3
40
2,4
60
3,6
80
4,8
70
4,2
Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Washing systems, garden irrigation, fountains
Dimensions mm.
Model
Weight
DNA
DNM
kg
JET 600
400
147
160
190
182
1"
1"
13,7
JET 800
400
147
160
190
182
1"
1"
14,2
JET 1000
425
147
160
190
182
1"
1"
16,8
MODEL
Nominal
Power
Absorbed
Power
HP
kW
HP
kW
VOLTAGE
Amp.
F.
L/1'
JET 600 M
JET 600 T
0,8
0,6
0,9
0,7
1 ~ 220 240 V
3 ~ 230 400 V
3,2
1,9-1,1
N4176550
N4176560
JET 800 M
JET 800 T
0,75
1,3
1 ~ 220 240 V
3 ~ 230 400 V
4,5
3,6-2,1
12,5
N4173010
N4173020
JET 1000 M
JET 1000 T
1,36
1,5
1,1
1 ~ 220 240 V
3 ~ 230 400 V
5
3,8-2,2
16
17
20
30
40
50
60
70
0,3
1,2
1,8
2,4
3,6
4,2
43
40
30
24
17
48
46
39
33
27
50
48
41
37
32
28
18
PRICE
3
m /h
N4171010
N4171020
Discharge head
in meters
CODE
JET
SURFACE PUMPS
SELF-PRIMING CAST IRON
JET PUMPS
The JET series self-priming pumps combine
the functional benefits of centrifugal pumps and
the practical benefits of self-priming pumps.
The Venturi system the pumps are fitted with
guarantees optimum hydraulic efficiency and
considerable pressure capacity.
Design Features
- Cast iron pump casing
- Cast iron motor bracket
- Pressed brass alloy impeller
- Technopolymer diffusor, Venturi tube and
nozzle
- Stainless steel shaft
- Graphite mechanical seal with ceramic
counterface
80
70
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
100
/68
60
100
/80
50
160/60
160/52
100/5
0
40
30
20
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 8 m
with foot valve
- Maximum operating pressure 10 bar
10
Hm
Q
20
1,2
L / 1'
m3/ h
60
3,6
40
2,4
100
6
80
4,8
120
7,2
140
8,4
160
9,6
Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Washing systems, garden irrigation, fountains
Dimensions mm.
Model
A
Weight
H2
H1
DNA
DNM
kg
1/2"
JET 100/50
180
157
500
220
180
235
170
227
1"
27
180
157
500
220
180
235
170
227
1 1/2"
1"
29
227
1"
31
CODE
MODEL
157
180
Nominal
Power
500
Absorbed
Power
HP
kW
HP
kW
220
180
235
170
L/1'
VOLTAGE
Amp.
F.
N4175010
N4175020
JET 100/50 M
JET 100/50 T
1,5
1,1
2,2
1,6
1 ~ 230 V
3 ~ 230 400 V
7,4
5-2,5
31,5
N4175030
N4175040
JET 100/68 M
JET 100/68 T
1,5
2,7
1 ~ 230 V
3 ~ 230 400 V
10,5
7,5-4,3
31,5
N4175050
JET 100/80 T
2,2
3,4
2,5
3 ~ 230 400 V
8,2-4,8
N4175080
N4175090
JET 160/52 M
JET 160/52 T
1,5
2,7
1 ~ 230 V
3 ~ 230 400 V
10,5
7,5-4,3
N4175100
JET 160/60 T
2,2
3,4
2,5
3 ~ 230 400 V
9,2-5,3
18
31,5
20
40
60
80
0,3
1,2
2,4
3,6
4,8
50
45
40
35
32
27
65
60,5
55
48
43
35
77
70,5
65
58
52
45
52
49,5
46
43
39,5
60
58
54,5
51
47
Q
3
m /h
Discharge head
in meters
1/2"
PRICE
7,2
8,4
36
33,5
30
44
40
38
AP
SURFACE PUMPS
DEEP SUCTION SELF-PRIMING
PUMPS COMPLETE WITH EJECTOR
The JET AP 800, AP 1000 pumps are suitable for
deep suction from wells with a minimum diameter
of 4" using a recirculation system.
Design Features
- Cast iron pump casing AP 800/AP 1000
- Cast iron motor bracket
- Technopolymer diffusor, impeller, Venturi tube and
nozzle AP 800/AP 1000
- Stainless steel shaft
- Graphite mechanical seal with ceramic counterface
Cast Iron Ejector
- supplied as standard N30 (on request N20)
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Three phase power supply with external protection
provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height with foot
valve: AP 800 = 30m AP 1000 = 35m
- Maximum operating pressure 6 bar
Applications
- Pumping and distribution
- Booster systems
Dimensions mm.
Model
Weight
DNA
AP 800
340
147
182
92
AP 1000
365
147
182
92
Nominal
Power
Absorbed
Power
CODE
MODEL
HP
kW
HP
VOLTAGE
Amp.
F.
kW
DNM
DNME
kg
43
1 /4 "
1"
1"
13,2
43
1 1 /4 "
1"
1"
15,8
Max
Suction
Ejector Suction
Type
m
L/1' 10 15 20 25 30 40 50
Q
m3/h 0,6 0,9 1,2 1,5 1,8 2,4 3
15
35
22
20
21
10
11
25
22
16
11
15
10
49
33
22
31
19
10
25
27
22
16
11
30
19
16
10
35
14
10
N20
AP 800 M
0,75
1,3
1 ~ 220 240 V
4,5
12,5
30
N30
30
15
N20
20
N4173030
AP 1000 M
1,36
1,5
1,1
1 ~ 220 240 V
16
35
N30
19
Discharge head
in meters
N4176630
11
PRICE
MCX
SURFACE PUMPS
MULTISTAGE
CENTRIFUGAL PUMPS
The MCX series horizontal multistage centrifugal
p u m p s o ff e r t h e f o l l o w i n g b e n e f i t s :
- High hydraulic pressure and flow rate
performance
- Minimum electric energy consumption
- Extremely silent operation
Design Features
- Stainless steel pump casing AISI304
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel
shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic
counterface
60
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
50
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 6m
with foot valve
- Maximum operating pressure 7 bar
10
80 / 6
40
80/4
30
80/36
20
Hm
Q
10
0,6
L / 1'
m3/ h
30
1,8
20
1,2
50
3
40
2,4
60
3,6
80
4,8
70
4,2
Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Firefighting systems
- Washing systems, irrigation
Dimensions mm.
Model
Weight
DNA
DNM
Kg
MCX 80/36
90
296
99
190
174
1"
1"
MCX 80/48
90
318
99
190
174
1"
1"
MCX 80/60
90
360
99
195
174
1"
1"
MODEL
Absorbed
Power
VOLTAGE
Amp.
F.
L/1'
kW
HP
kW
0,6
0,45
0,8
0,6
1 ~ 230 V
3 ~ 230 400 V
2,9
2-1,2
12,5
0,75
0,55
1,1
0,8
1 ~ 230 V
3 ~ 230 400 V
4
2,6-1,5
12,5
0,75
1,3
1 ~ 230 V
3 ~ 230 400 V
4,8
2,9-1,7
16
20
20
40
60
80
100
1,2
2,4
3,6
4,8
35
28
21
13
0,5
45
36
28
17
57
50
40
27
PRICE
3
m /h
HP
Discharge head
in meters
CODE
Nominal
Power
SURFACE PUMPS
MULTISTAGE
CENTRIFUGAL PUMPS
The MCX series horizontal multistage centrifugal
p u m p s o ff e r t h e f o l l o w i n g b e n e f i t s :
- High hydraulic pressure and flow rate
performance
- Minimum electrical energy consumption
- Extremely silent operation
Design Features
- Stainless steel pump casing AISI 304
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel
shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic
counterface
60
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
50
1 20
40
12 0
30
120/3
/6 0
/4 8
20
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 6 m
with foot valve
- Maximum operating pressure 7 bar
10
Hm
Q
20
1,2
L / 1'
m3/ h
60
3,6
40
2,4
80
4,8
100
6
120
7,2
Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Firefighting systems
- Washing systems, irrigation
Dimensions mm.
Model
Weight
DNA
DNM
Kg
MCX 120/36
90
316
99
195
174
1"
1"
MCX 120/48
90
338
99
195
174
1"
1"
MCX 120/60
90
360
99
195
174
1"
1"
10
MODEL
Absorbed
Power
VOLTAGE
Amp.
F.
L/1'
kW
HP
kW
0,75
1,1
0,8
1 ~ 230 V
3 ~ 230 400 V
3,5
2,9-1,7
12,5
0,75
1,5
1,1
1 ~ 230 V
3 ~ 230 400 V
4,6
3,6-2,1
16
1,2
0,9
1,7
1,25
1 ~ 230 V
3 ~ 230 400 V
5,8
3,5-2
20
21
20
40
60
80
100
1,2
2,4
3,6
4,8
36
33
28
22
14
48
42
37
27
18
60
55
48
36
26
10
PRICE
3
m /h
HP
Discharge head
in meters
CODE
Nominal
Power
MCX
SURFACE PUMPS
MULTISTAGE
CENTRIFUGAL PUMPS
The MCX series horizontal multistage centrifugal
p u m p s o ff e r t h e f o l l o w i n g b e n e f i t s :
- High hydraulic pressure and flow rate
performance
- Minimum electrical energy consumption
- Extremely silent operation
Design Features
- Stainless steel pump casing AISI 304
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel
shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic
counterface
BA010042/01.06.01
BA000062/14.06.00
BA000011/29.03.99
70
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
60
2 0 0/
65
2 0 0/ 5
2
50
40
2 0 0 /4 0
30
20
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 6 m
with foot valve
- Maximum operating pressure 7 bar
10
Hm
Q
20 30
1,2 1,8
L / 1'
m3/ h
40 60
2,4 3,6
Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Firefighting systems
- Washing systems, irrigation
Dimensions mm.
Model
A
Weight
DNA
DNM
kg
1 /4 "
14
MCX 200/40
105
400
141
235
205
MCX 200/52
105
430
141
235
205
1 1/4"
1 1 /4 "
16
205
1 1/4"
1 1 /4 "
18
CODE
105
MODEL
Nominal
Power
460
Absorbed
Power
HP
kW
HP
kW
141
VOLTAGE
235
Amp.
F.
L/1'
MCX 200/40 M
MCX 200/40 T
1,5
1,1
1,5
1 ~ 230 V
3 ~ 230 400 V
7
3,6-2,1
20
N4201380-B
N4201390-B
MCX 200/52 M
MCX 200/52 T
1,8
1,3
2,5
1,8
1 ~ 230 V
3 ~ 230 400 V
8,5
5-2,9
25
N4201400-B
MCX 200/65 T
1,9
1,4
2,7
3 ~ 230 400 V
6-3,5
22
20
40
80
1,2
2,4
4,8
7,2
9,6
38
35
32
26
19
11
49
47
44
38
29
18
62
59
55
47
36
22
PRICE
3
m /h
N4201360-B
N4201370-B
Discharge head
in meters
MCX 200/65
1/4"
12
SURFACE PUMPS
MULTISTAGE
CENTRIFUGAL PUMPS
The DHR series horizontal multistage centrifugal
p u m p s o ff e r t h e f o l l o w i n g b e n e f i t s :
- High hydraulic pressure and flow rate
performance
- Minimum electrical energy consumption
- Extremely silent operation
Design Features
- Pump casing built in stages in AISI 304
stainless steel
- Motor bracket in GG20 cast iron
- Suction flange in GG20 cast iron
- Impellers and diffusors in AISI 304 stainless
steel
- Shaft in AISI 316 stainless steel
- NBR rubber O ring
- Mechanical seal with graphite/ceramic
counterfaces
Motor
- Enclosed, externally ventilated
- Level of protection IP 54
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- M a x i m u m l i q u i d t e m p e r a t u re 9 0 C
- Maximum recommended suction height 6 m
with foot valve (with max. liquid temp. at 50C)
- Maximum operating pressure 6 bar
Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Washing systems, garden irrigation, fountains
Nominal
Power
Absorbed
Power
HP
kW
HP
VOLTAGE
Amp.
F.
m /h
DHR 23 M
DHR 23 T
0,5
0,5
0,37
0,37
0,65
0,62
2,4
1,75 - 1
14
E0502105
E0501005
DHR 25 M
DHR 25 T
0,75
0,75
0,55
0,55
3,8
0,98 0,725
1 ~ 230 V
0,95 0,7 3 ~ 230 400 V 2,45 - 1,4
16
MODEL
Nominal
Power
0,48
1 ~ 230 V
0,46 3 ~ 230 400 V
Absorbed
Power
HP
kW
HP
VOLTAGE
Amp.
F.
E1502102
E1501002
DHR 42 M
DHR 42 T
0,5
0,5
0,37
0,37
0,73
0,7
1 ~ 230 V
0,54
0,52 3 ~ 230 400 V
2,6
1,9 - 1,1
14
E1502103
E1501003
DHR 43 M
DHR 43 T
0,75
0,75
0,55
0,55
1
0,99
0,75
1 ~ 230 V
0,73 3 ~ 230 400 V
3,9
2,6 - 1,5
16
E1502104
E1501004
DHR 44 M
DHR 44 T
1
1
0,75
0,75
1,33
1,25
0,98
1 ~ 230 V
5
0,92 3 ~ 230 400 V 2,95 - 1,7
20
E1502105
E1501005
DHR 45 M
DHR 45 T
1,5
1,5
1,1
1,1
1,7
1,61
6,3
1,25
1 ~ 230 V
1,19 3 ~ 230 400 V 4,2 - 2,4
32
E1502106
E1501006
DHR 46 M
DHR 46 T
1,5
1,5
1,1
1,1
1,97
1,87
1,45
1 ~ 230 V
1,38 3 ~ 230 400 V
7,4
4,5 - 2,6
32
23
20
30
40
50
0,6
1,2
1,8
2,4
28
26
23
19
15
44
42
37
32
25
L/1'
40
60
80
100 120
2,4
3,6
4,8
7,2
16
14
12
23
20
17
14
10
30
27
23
18
13
39
35
30
24
17
47
42
35
28
20
Q
3
m /h
kW
10
PRICE
3
kW
E0502103
E0501003
CODE
L/1'
Q
Discharge head
in meters
MODEL
Discharge head
in meters
CODE
PRICE
DHR
DHR 42 /43 / 44
45 / 46
50 Hz
DHR 23 /25
50 Hz
Weight
Dimensions mm.
Model
DNA
DNM
L1
L2
L3
L4
DHR 23
368
120
109
140
1"
1"
11,3
DHR 25
422
168
157
193
1"
1"
12,6
110
1/4"
1"
11,3
DHR 42
342
93
85
kg
DHR 43
370
120
110
137
1 1/4"
1"
12,3
DHR 44
396
144
133
165
1 1/4"
1"
13,6
1"
15,8
1"
17,2
DHR 45
445
173
162
190
1 1/4"
DHR 46
470
200
189
217
1 1/4"
24
SURFACE PUMPS
MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The DHI series horizontal multistage centrifugal pumps
offer the following benefits:
- High hydraulic pressure and flow rate performance
- Minimum electrical energy consumption
- Extremely silent operation
Design Features
- Pump casing in AISI 316 stainless steel
- Aluminium motor coupling bracket
- Seal holder plate in AISI 316 stainless steel
- Impellers and diffusors in AISI 316 stainless steel
- Shaft in AISI 316 stainless steel
- EPDM rubber O ring
- Mechanical seal with graphite/ceramic counterfaces
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Three phase power supply with external protection
provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Types of pumped liquid: clear, non-explosive with
no suspended solids or abrasive material
- Special liquids such as: softened demineralised
water, washing system solutions, oils, non-aggressive
chemical compound fluids
- Maximum liquid temperature 90C
- Maximum recommended suction height 6 m with
foot valve (with max. liquid temp. at 50C)
- Maximum operating pressure 6 bar
Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent basis
- Booster systems
- Washing systems, garden irrigation, fountains
- Condensate conveyance
- Food and wine industries
- As a component of industrial machinery
Nominal
Power
Absorbed
Power
HP
kW
HP
kW
VOLTAGE
Amp.
F.
DHI 24 M
DHI 24 T
0,75
0,55
1,00
0,75
1 ~ 230 V
3 ~ 400 V
3,4
1,4
16
N4221010
N4221080
DHI 26 M
DHI 26 T
1,00
0,75
1,30
0,95
1 ~ 230 V
3 ~ 400 V
4,3
2,0
20
N4221020
N4221090
DHI 27 M
DHI 27 T
1,25
0,9
1,65
1,20
1 ~ 230 V
3 ~ 400 V
5,3
2,4
32
VOLTAGE
Amp.
F.
MODEL
Nominal
Power
HP
kW
Absorbed
Power
HP
kW
m /h
N4221000
N4221070
CODE
L/1'
DHI 43 M
DHI 43 T
0,75
0,55 1,00
0,75
1 ~ 230 V
3 ~ 400 V
3,5
1,6
16
N4221040
N4221110
DHI 44 M
DHI 44 T
1,00
0,75
1,36
1,00
1 ~ 230 V
3 ~ 400 V
4,6
2,0
20
N4221050
N4221060
DHI 45 M
DHI 45 T
1,25
0,9
1,70
1,25
1 ~ 230 V
3 ~ 230 400 V
5,9
2,5
25
25
20
30
40
50
60
0,6
1,2
1,8
2,4
3,6
35
32
28
25
20
16
52
46
40
34
27
19
63
57
50
43
35
26
L/1'
40
60
80
2,4
3,6
4,8
7,2
24
22
18
16
12
33
31
27
22
16
42
36
33
27
18
100 120
Q
3
m /h
N4221030
N4221100
10
Discharge head
in meters
MODEL
Discharge head
in meters
CODE
PRICE
PRICE
DHI
DHI 24 / 26 / 27
50Hz
DHI 43 / 44 / 45
50 Hz
Weight
Dimensions mm.
Model
A
DNA
DNM
Kg
11/4
11,3
12,6
DHI 24
105
400
141
235
205
11/4
DHI 26
105
430
141
235
205
11/4
11/4
11/4
11,3
DHI 27
105
460
141
235
205
11/4
DHI 43
105
400
141
235
205
11/4
11/4
12,3
DHI 44
105
430
141
235
205
11/4
11/4
13,6
DHI 45
105
460
141
235
205
11/4
11/4
15,8
26
SURFACE PUMPS
SELF-PRIMING MULTISTAGE
CENTRIFUGAL PUMPS
The MAX series horizontal multistage centrifugal
pumps offer the following benefits:
- High hydraulic pressure and flow rate
performance
- Minimum electrical energy consumption
- Extremely silent operation
Design Features
- Stainless steel pump casing AISI 304
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel
shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic
counterface
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 7 m
with foot valve
- Maximum operating pressure 7 bar
60
50
80 / 6
40
80/4
30
20
10
Hm
Q
L / 1'
m3/ h
10
0,6
30
1,8
20
1,2
50
3
40
2,4
60
3,6
80
4,8
70
4,2
Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Firefighting systems
- Washing systems, irrigation
Water recycling in the pump casing only takes
place during the priming stage, after which the
special valve closes recirculation achieving
maximum flow rate.
Dimensions mm.
Model
Weight
DNA
DNM
kg
MAX 80/48
129
370
99
182
176
1"
1"
MAX 80/60
129
392
99
182
176
1"
1"
MODEL
Nominal
Power
Absorbed
Power
VOLTAGE
Amp.
F.
L/1'
kW
HP
kW
0,75
0,55
1,1
0,8
1 ~ 230 V
3 ~ 230 400 V
4
2,6-1,5
12,5
0,75
1,3
1 ~ 230 V
3 ~ 230 400 V
4,8
2,9-1,7
16
27
20
40
60
80
1,2
2,4
3,6
4,8
45
36
28
17
57
50
40
27
PRICE
3
m /h
HP
Discharge head
in meters
CODE
MAX
SELF-PRIMING MULTISTAGE
CENTRIFUGAL PUMPS
The MAX series horizontal multistage centrifugal
p u m p s o ff e r t h e f o l l o w i n g b e n e f i t s :
- High hydraulic pressure and flow rate
performance
- Minimum electrical energy consumption
- Extremely silent operation
Design Features
- Stainless steel pump casing AISI 304
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel
shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic
counterface
60
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
50
1 20
40
12 0
/6 0
/4 8
30
20
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 7 m
with foot valve
- Maximum operating pressure 7 bar
10
Hm
Q
20
1,2
L / 1'
m3/ h
Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Firefighting systems
- Washing systems, irrigation
60
3,6
40
2,4
100
6
80
4,8
120
7,2
Weight
Dimensions mm.
Model
A
DNA
DNM
kg.
MAX 120/48
129
393
99
192
176
1"
1"
10
MAX 120/60
129
415
99
192
176
1"
1"
11
MODEL
Absorbed
Power
VOLTAGE
Amp.
F.
HP
kW
HP
kW
0,75
1,5
1,1
1 ~ 230 V
3 ~ 230 400 V
4,6
3,6-2,1
16
1,2
0,9
1,7
1,25
1 ~ 230 V
3 ~ 230 400 V
5,8
3,5-2
20
28
L/1'
20
40
60
80
100
m3/h
1,2
2,4
3,6
4,8
48
42
37
27
18
60
55
48
36
26
10
PRICE
Discharge head
in meters
CODE
Nominal
Power
MULTINOX-A
SURFACE PUMPS
SELF-PRIMING MULTISTAGE
CENTRIFUGAL PUMPS
The horizontal multistage centrifugal self-priming
MULTINOX-A pumps are suitable for developing a
considerable pressure and flow rate with extremely
silent operation and with minimum electrical energy
consumption.
Design Features
- Stainless steel outer liner
- Cast iron motor bracket
- Cast iron suction flange
- Technopolymer impellers with
stainless steel shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic counterface
- Special patented brass valve for closure during the
priming stage
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Three phase power supply with external protection
provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 8 m with
foot valve
- Maximum operating pressure 9 bar
RIMING
SELF-P
80
70
200
60
/ 80
20 0/
65
200/5
2
2 0 0 /4 0
50
40
30
20
10
Hm
Q
80
4,8
40
2,4
L / 1'
m3/ h
120
7,2
160
9,6
200
12
Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent basis
- Booster systems
- Washing systems, garden irrigation, fountains
Water recycling in the pump casing only takes place
during the priming stage, after which the special valve
closes recirculation achieving maximum flow rate.
Weight
Dimensions mm.
Model
A
DNA
DNM
kg
MULTINOX 200/40
441
200
188
155
170
1 1 /4 "
1 1/4"
19
MULTINOX 200/52
469
200
215
155
170
1 1 /4 "
1 1/4"
21
MULTINOX 200/65
497
200
243
155
170
1 1 /4 "
1 1/4"
23
MULTINOX 200/80
525
200
270
155
170
1 1 /4 "
1 1/4"
25
MODEL
Nominal Absorbed
Power
Power
VOLTAGE
Amp.
F. Q
HP kW HP kW
1,5 1,1
1,5
L/1'
20
40
80
120
160
m3/h
1,2
2,4
4,8
7,2
9,6
38
37
32
24
12
50
49
42
32
18
63
60
52
40
24
77
73
62
48
27
20
1 ~ 220240 V
3 ~ 230400 V
3,6-2,1
1 ~ 220240 V
8,5
3 ~ 230400 V
5-2,9
3 ~ 230400 V
6-3,5
3 ~ 230400 V
8-4,6
29
25
Discharge head
in meters
CODE
PRICE
MULTINOX-VE
SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The MULTINOX-VE vertical multistage
centrifugal pumps are especially suitable for
the manufacture of pumping assemblies, above
all in cases where a high level of efficiency and
silence is required with reduced overall floor
dimensions.
Design Features
- Stainless steel outer liner
- Cast iron motor bracket
- Cast iron suction flange
- Technopolymer impellers with stainless steel
shim ring
- Technopolymer diffusors
- Stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic
counterface
100
90
80
70
60
50
40
30
20
10
Motor
- Enclosed, externally ventilated
- Level of protection IP 44
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection
built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 50C
- Maximum recommended suction height 6 m
with foot valve
- Maximum operating pressure 9 bar
200/9
0
200/8
0
200/65
200/52
200/40
Hm
Q
80
4,8
40
2,4
L / 1'
m3/ h
120
7,2
160
9,6
200
12
Applications
- Pumping and distribution of water in domestic
systems used on a continuous or intermittent
basis
- Booster systems
- Firefighting systems
- Washing systems, garden irrigation, fountains
Dimensions mm.
Model
CODE
MODEL
A
438
466
504
525
555
B
115
115
115
115
115
Nominal Absorbed
Power
Power
C
37
37
37
37
37
VOLTAGE
D
143
174
203
230
257
Amp.
F. Q
HP kW HP kW
N4194010 -B
N4194020 -B
N4194030 -B
N4194040 -B
MULTINOX 200/40 M VE
MULTINOX 200/40 T VE
MULTINOX 200/52 M VE
MULTINOX 200/52 T VE
1,5 1,1
1,5
1 ~ 220240 V
3 ~ 230400 V
1 ~ 220240 V
3 ~ 230400 V
7
3,6-2,1
8,5
5-2,9
3 ~ 230400 V
6-3,5
3 ~ 230400 V
8-4,6
3 ~ 230400 V
9-5,2
30
E
204
204
204
204
204
DNA
1 1/4"
1 1/4"
1 1/4"
1 1/4"
1 1 /4 "
DNM
1 1/4"
1 1/4"
1 1/4"
1 1/4"
1 1/4"
L/1'
20
40
80
120
160
m3/h
1,2
2,4
4,8
7,2
9,6
38
37
32
24
12
50
49
42
32
18
63
60
52
40
24
77
73
62
48
27
83
78
67
54
33
20
25
Discharge head
in meters
MULTINOX 200/40 VE
MULTINOX 200/52 VE
MULTINOX 200/65 VE
MULTINOX 200/80 VE
MULTINOX 200/90 VE
Weight
kg
19
21
23
25
27
PRICE
SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 2Bs are vertical multistage centrifugal pumps with "in line" suction
and delivery points directly connected to an electric motor. They are not
self-priming.
Design Features
- Impellers, diffusors, intermediate chambers and outer liner in AISI 304
stainless steel, shaft in AISI 431 stainless steel
- Base and head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- All the version "A" VLR are complete with 1" oval gas counterflanges
- For the version "F" VLR , round DN32 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure:
Oval flanges
: 16 bar
DIN flanges
: 25 bar (maximum pumped liquid temperature 40 C)
: 21 bar (maximum pumped liquid temperature 120 C)
- Maximum inlet pressure:
VLR 2B-30/2
=
6 bar
VLR 2B-30 - VLR 2B-110 = 10 bar
VLR 2B-130 - VLR 2B-260 = 15 bar
- Minimum suction head:
Please refer to NPSH plus a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer
CODE
Motor
Power
MODEL
VOLTAGE
HP
kW
Amp.
F.
L/1'
10
20
30
40
50
0,6
1,2
1,8
2,4
19
18
17
14
11
29
27
25
21
17
37
35
32
29
23
47
43
40
35
28
56
51
48
42
33
65
60
55
49
39
84
78
70
62
50
100
93
84
74
60
89
71
99
81
99
PRICE
3
m /h
VLR 2B - 30/2 A M
VLR 2B - 30/2 A T
0,5
0,37
1 ~ 230 V
3 ~ 230 400 V
2,7
1-0,6
14
E2302103
E2301003
VLR 2B - 30 A M
VLR 2B - 30 A T
0,5
0,37
1 ~ 230 V
3 ~ 230 400 V
2,7
1,4-0,8
14
E2302104
E2301004
VLR 2B - 40 A M
VLR 2B - 40 A T
0,75
0,55
1 ~ 230 V
3 ~ 230 400 V
4
1,8-1
16
E2302105
E2301005
VLR 2B - 50 A M
VLR 2B - 50 A T
0,75
0,55
1 ~ 230 V
3 ~ 230 400 V
4
2,3-1,3
16
E2302106
E2301006
VLR 2B - 60 A M
VLR 2B - 60 A T
0,75
1 ~ 230 V
3 ~ 230 400 V
5,2
2,7-1,5
25
E2302107
E2301007
VLR 2B - 70 A M
VLR 2B - 70 A T
0,75
1 ~ 230 V
3 ~ 230 400 V
5,2
3-1,7
25
E2302109
E2301009
VLR 2B - 90 A M
VLR 2B - 90 A T
1,5
1,1
1 ~ 230 V
3 ~ 230 400 V
8
3,6-2,1
35
E2302111
E2301011
VLR 2B - 110 A M
VLR 2B - 110 A T
1,5
1,1
1 ~ 230 V
3 ~ 230 400 V
8
4,3-2,5
35
E2302113
E2301013
VLR 2B - 130 A M
VLR 2B - 130 A T
1,5
1 ~ 230 V
3 ~ 230 400 V
12
5-2,9
45
E2302115
E2301015
VLR 2B - 150 A M
VLR 2B - 150 A T
1,5
1 ~ 230 V
3 ~ 230 400 V
12
5,7-3,3
45
E2331018
VLR 2B - 180 F T
2,2
3 ~ 230 400 V
7,2-4,1
E2331022
VLR 2B - 220 F T
2,2
3 ~ 230 400 V
8,7-5
E2331026
VLR 2B - 260 F T
3 ~ 230 400 V
11,4-6,6
31
Discharge head
in meters
E2302102
E2301002
VLR 2B
Version with oval flanges
VLR 2B 30/2 - VLR 2B 150
H
B1
50
A1
L1
3/4"
22
60
100
156
160
22
65
3/8"
20
M 10x40
1"gas
104
180
210
13,5
H
D
B1
A2
L2
3/4"
3/8"
3/8"
75
A1 1
60
100
156
250
3/8"
20
32
78
100
140
n4 holes 18
104
180
210
13,5
4 holes
Net Weight
(kg)
Dimensions (mm)
Model
VLR 2B - 30/2
VLR 2B - 30
VLR 2B - 40
VLR 2B - 50
VLR 2B - 60
VLR 2B - 70
VLR 2B - 90
VLR 2B - 110
VLR 2B - 130
VLR 2B - 150
VLR 2B - 180
VLR 2B - 220
VLR 2B - 260
238
238
256
274
296
314
350
386
441
477
-
32
B1
213
213
213
213
237
237
237
237
265
265
265
265
315
L1 1
451
451
469
487
533
551
587
623
706
742
-
A2 2
556
628
704
L2 2
821
893
1019
142
142
142
142
160
160
160
160
185
185
185
185
200
109
109
109
109
131
131
131
131
130
130
130
130
140
20
21
23
25
26
33
34
36
37
43
-
49
61
63
SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 4s are vertical multistage centrifugal pumps with "in line" suction
and delivery points directly connected to an electric motor. They are not
self-priming.
Design Features
- Impellers, diffusors, intermediate chambers and outer liner in AISI 304
stainless steel, shaft in AISI 431 stainless steel
- Base and head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- All the version "A" VLR are complete with 11/4" oval gas counterflanges
- For the version "F" VLR, round DN32 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure:
Oval flanges
: 16 bar
DIN flanges
: 25 bar (maximum pumped liquid temperature 40 C)
: 21 bar (maximum pumped liquid temperature 120 C)
- Maximum inlet pressure:
VLR 4- 20
= 6 bar
VLR 4- 30 - VLR 4-100 = 10 bar
VLR 4-120 - VLR 4-260 = 15 bar
- Minimum suction head:
Please refer to NPSH plus a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer
CODE
Motor
Power
MODEL
HP
kW
VOLTAGE
F.
Amp.
L/1'
40
60
80
100 120
2,4
3,6
4,8
7,2
19
17
15
13
28
25
22
19
13
36
33
29
25
18
44
42
37
31
23
53
50
44
38
27
61
58
51
44
32
71
67
59
50
37
90
82
72
61
46
99
Q
3
m /h
VLR 4 - 20 A M
VLR 4 - 20 A T
0,5
0,37
1 ~ 230 V
3 ~ 230 400 V
2,7
1,73-1
14
E3502103
E3501003
VLR 4 - 30 A M
VLR 4 - 30 A T
0,75
0,55
1 ~ 230 V
3 ~ 230 400 V
4
2,5-1,45
16
E3502104
E3501004
VLR 4 - 40 A M
VLR 4 - 40 A T
0,75
1 ~ 230 V
3 ~ 230 400 V
5,2
3,3-1,9
25
E3502105
E3501005
VLR 4 - 50 A M
VLR 4 - 50 A T
1,5
1,1
1 ~ 230 V
3 ~ 230 400 V
8
4,3-2,5
35
E3502106
E3501006
VLR 4 - 60 A M
VLR 4 - 60 A T
1,5
1,1
1 ~ 230 V
3 ~ 230 400 V
8
4,3-2,5
35
E3502107
E3501007
VLR 4 - 80/7 A M
VLR 4 - 80/7 A T
1,5
1 ~ 230 V
3 ~ 230 400 V
12
5,9-3,4
45
E3502108
E3501008
VLR 4 - 80 A M
VLR 4 - 80 A T
1,5
1 ~ 230 V
3 ~ 230 400 V
12
5,9-3,4
45
E3501010
VLR 4 - 100 A T
2,2
3 ~ 230 400 V
8,3-4,8
E3501012
VLR 4 - 120 A T
2,2
3 ~ 230 400 V
8,3-4,8
107
87
73
54
E3501014
VLR 4 - 140 A T
3 ~ 230 400 V
10,9-6,3
85
63
E3501016
VLR 4 - 160 A T
3 ~ 230 400 V
10,9-6,3
97
72
E3531019
E3531119
VLR 4 - 190 F T
VLR 4 - 190 F T
5,5
3 ~ 230 400 V
3 ~ 400 690 V
13,8-8
86
E3531022
E3531122
VLR 4 - 220 F T
VLR 4 - 220 F T
5,5
3 ~ 230 400 V
3 ~ 400 690 V
13,8-8
E3531024
E3531124
VLR 4 - 240 F T
VLR 4 - 240 F T
7,5
5,5
3 ~ 230 400 V
3 ~ 400 690 V
12,4-21,5
E3531026
E3531126
VLR 4 - 260 F T
VLR 4 - 260 F T
7,5
5,5
3 ~ 230 400 V
3 ~ 400 690 V
12,4-21,5
33
Discharge head
in meters
E3502102
E3501002
PRICE
VLR 4
Version with oval flanges
VLR 4-20 - VLR 4-160
H
B1
50
A1
L1
3/4"
22
60
100
156
160
22
65
3/8"
20
M 10x40
1 /4"gas
104
180
210
13,5
H
D
B1
Net weight
(kg)
Dimensions (mm)
3/4"
A1 1
3/8"
3/8"
75
A2
L2
Model
60
100
156
250
3/8"
20
32
78
100
140
n4 holes 18
104
180
210
13,5
4 holes
VLR 4 - 20
VLR 4 - 30
VLR 4 - 40
VLR 4 - 50
VLR 4 - 60
VLR 4 - 80/7
VLR 4 - 80
VLR 4 - 100
VLR 4 - 120
VLR 4 - 140
VLR 4 - 160
VLR 4 - 190
VLR 4 - 220
VLR 4 - 240
VLR 4 - 260
238
265
296
323
350
423
423
477
531
589
643
-
34
B1
213
213
237
237
237
265
265
265
265
315
315
335
335
385
385
L1 1
451
478
533
560
587
688
688
742
796
904
958
-
A2 2
749
830
911
965
L2 2
1084
1165
1298
1350
142
142
160
160
160
185
185
185
185
200
200
200
200
260
260
109
109
131
131
131
130
130
130
130
140
140
140
140
185
185
20
21
23
25
26
33
33
36
37
41
43
-
61
63
87
89
SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 8s are vertical multistage centrifugal pumps with "in line" suction
and delivery points directly connected to an electric motor.
They are not self-priming.
Design Features
- Impellers, diffusors, intermediate chambers and outer liner in AISI 304
stainless steel, shaft in AISI 431 stainless steel
- Base and head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- All the version "A" VLR are complete with 11/2" oval gas counterflanges
- For the version "F" VLR, round DN40 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure:
Oval flanges
: 16 bar
DIN flanges
: 25 bar (maximum pumped liquid temperature 85 C)
: 23 bar (maximum pumped liquid temperature 120 C)
- Maximum inlet pressure:
VLR 8-20 - VLR 8- 30 = 6 bar
VLR 8-40 - VLR 8-200 = 10 bar
- Minimum suction head:
please refer to the NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer
CODE
Motor
Power
MODEL
HP
kW
VOLTAGE
F.
Amp.
L/1'
50
Q
3
m /h
10,5
12
21
20
18
15
13
32
30
27
23
19
42
40
35
30
26
VLR 8 - 20 A M
VLR 8 - 20 A T
0,75
1 ~ 230 V
3 ~ 230 400 V
5,2
3,3-1,9
25
E4502103
E4501003
VLR 8 - 30 A M
VLR 8 - 30 A T
1,5
1,1
1 ~ 230 V
3 ~ 230 400 V
8
4,3-2,5
35
E4502104
E4501004
VLR 8 - 40 A M
VLR 8 - 40 A T
1,5
1 ~ 230 V
3 ~ 230 400 V
12
5,9-3,4
45
E4501005
VLR 8 - 50 A T
2,2
3 ~ 230 400 V
8,8-5,1
53
50
44
38
32
E4501006
VLR 8 - 60 A T
2,2
3 ~ 230 400 V
8,8-5,1
64
60
52
45
39
E4501008
VLR 8 - 80 A T
3 ~ 230 400 V
11,8-6,8
85
80
70
60
52
E4501010
E4501110
VLR 8 - 100 A T
VLR 8 - 100 A T
5,5
3 ~ 230 400 V
3 ~ 400 690 V
16,8-9,7
106 100
88
76
65
E4501012
E4501112
VLR 8 - 120 A T
VLR 8 - 120 A T
5,5
3 ~ 230 400 V
3 ~ 400 690 V
16,8-9,7
90
77
E4531014
E4531114
VLR 8 - 140 F T
VLR 8 - 140 F T
7,5
5,5
3 ~ 230 400 V
3 ~ 400 690 V
21,5-12,4
92
E4531016
E4531116
VLR 8 - 160 F T
VLR 8 - 160 F T
7,5
5,5
3 ~ 230 400 V
3 ~ 400 690 V
21,5-12,4
E4531018
E4531118
VLR 8 - 180 F T
VLR 8 - 180 F T
10
7,5
3 ~ 230 400 V
3 ~ 400 690 V
28-16,4
E4531020
E4531120
VLR 8 - 200 F T
VLR 8 - 200 F T
10
7,5
3 ~ 230 400 V
3 ~ 400 690 V
28-16,4
Discharge head
in meters
E4502102
E4501002
35
PRICE
VLR 8
Version with oval flanges
VLR 8-20 - VLR 8-120
H
B1
80
A1
L1
3/4"
27
130
190
200
27
100
20
M 12x45
1"1/2 gas
155
215
246
13
B1
A2
L2
D3
3/8"
3/8"
Net Weight
(kg)
Dimensions (mm)
Model
80
A1 1
130
190
280
3/8"
20
40
88
110
150
n4 holes 18
155
215
246
13
4 holes
VLR 8 - 20
VLR 8 - 30
VLR 8 - 40
VLR 8 - 50
VLR 8 - 60
VLR 8 - 80
VLR 8 - 100
VLR 8 - 120
VLR 8 - 140
VLR 8 - 160
VLR 8 - 180
VLR 8 - 200
245
375
420
450
480
545
605
665
-
36
B1
237
237
265
265
265
315
335
335
385
385
385
385
L1 1
482
612
685
715
745
860
940
1000
-
A2 2
745
805
865
925
L2 2
1130
1190
1250
1310
D3
160
160
185
185
185
200
200
200
260
260
260
260
131
131
130
130
130
140
140
140
185
185
185
185
300
300
300
300
30
32
40
42
43
51
52
56
-
85
86
90
91
SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 16s are vertical multistage centrifugal pumps with "in line"
suction and delivery points directly connected to an electric motor. They
are not self-priming.
Design Features
- Impellers, diffusors, intermediate chambers and outer liner in AISI 304
stainless steel, shaft in AISI 431 stainless steel
- Base and head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- Version with DIN/ISO flanges:
Flanges DN 50 PN25 DIN 2534/ISO 7005-2
(with 65mm diameter bore)
Counterflanges available on request: - weldable DN 50 PN 25
- 2" threaded gas
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure:
VLR 16- 30/2 - VLR 16- 80
= 16 bar
VLR 16-100 - VLR 16-160
= 25 bar (max. temp. 85 C)
VLR 16-100 - VLR 16-160
= 23 bar (max. temp. 120 C)
- Maximum inlet pressure:
VLR 16-30/2 - VLR 16- 30
= 6 bar
VLR 16-40
- VLR 16-160
=10 bar
- Minimum suction head:
please refer to the NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer
CODE
Motor
Power
MODEL
HP
kW
L/1'
VOLTAGE
Amp.
Q
m3/h
12
15
18
21
VLR 16 - 30/2F T
2,2
3 ~ 230 400 V
8,8-5,1
29
27
26
22
18
E5501003
VLR 16 - 30 F T
3 ~ 230 400 V
11,8-6,8
43
40
37
32
27
E5501004
E5501104
VLR 16 - 40 F T
VLR 16 - 40 F T
5,5
3 ~ 230 400 V
3 ~ 400 690 V
16,8-9,7
58
54
52
44
37
E5501005
E5501105
VLR 16 - 50 F T
VLR 16 - 50 F T
7,5
5,5
3 ~ 230 400 V
3 ~ 400 690 V
21,5-12,4
72
68
65
56
46
E5501006
E5501106
VLR 16 - 60 F T
VLR 16 - 60 F T
7,5
5,5
3 ~ 230 400 V
3 ~ 400 690 V
21,5-12,4
87
81
78
68
58
E5501007
E5501107
VLR 16 - 70 F T
VLR 16 - 70 F T
10
7,5
3 ~ 230 400 V
3 ~ 400 690 V
28-16,4
101
95
90
80
67
E5501008
E5501108
VLR 16 - 80 F T
VLR 16 - 80 F T
10
7,5
3 ~ 230 400 V
3 ~ 400 690 V
28-16,4
92
76
E5501010
E5501110
VLR 16 - 100 F T
VLR 16 - 100 F T
15
11
3 ~ 230 400 V
3 ~ 400 690 V
40-23,5
98
E5501012
E5501112
VLR 16 - 120 F T
VLR 16 - 120 F T
15
11
3 ~ 230 400 V
3 ~ 400 690 V
40-23,5
E5501014
E5501114
VLR 16 - 140 F T
VLR 16 - 140 F T
20
15
3 ~ 230 400 V
3 ~ 400 690 V
50-29
E5501016
E5501116
VLR 16 - 160 F T
VLR 16 - 160 F T
20
15
3 ~ 230 400 V
3 ~ 400 690 V
50-29
37
Discharge head
in meters
E5501002
PRICE
VLR 16
H
D
D3
3/8"
90
3/8"
130
190
300
165
125
65
20
102
n 4 holes 18
DN 50
155
215
n 4 holes
13
246
Net Weight
(kg)
Dimensions (mm)
Model
VLR 16 - 30/2
VLR 16 - 30
VLR 16 - 40
VLR 16 - 50
VLR 16 - 60
VLR 16 - 70
VLR 16 - 80
VLR 16 - 100
VLR 16 - 120
VLR 16 - 140
VLR 16 - 160
D3
460
464
509
575
620
665
710
830
920
1010
1100
265
315
335
385
385
385
385
495
495
495
495
725
779
844
960
1005
1050
1095
1325
1425
1505
1595
185
200
200
260
260
260
260
260
260
310
310
130
140
140
185
185
185
185
185
185
230
230
140
250
250
300
300
300
300
350
350
350
350
38
52
56
59
82
84
90
92
136
140
181
185
SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 30Bs are vertical multistage centrifugal pumps with "in line"
suction and delivery points directly connected to an electric motor.
They are not self-priming.
Design Features
- Impellers, diffusor and upper spacer, shaft, outer liner and coupling
guard in stainless steel AISI 304
- Electric pump base and head and coupling in cast iron
- Shaft protected by a tungsten carbide liner
- Mechanical seal in silicon carbide and carbon (on request widia-widia)
- EPDM rubber O ring
- Supplied complete with counterflanges
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 20C to +120C
- M a x i m u m o p e r a t i n g p re s s u re i n c l u d i n g s u c t i o n h e a d :
16 bar (VLR 30-20 - VLR 30-60)
25 bar (VLR 30-70 - VLR 30-120)
- Minimum suction head:
please refer to the NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general.
CODE
Motor
Power
MODEL
VOLTAGE
HP
kW
Amp.
L/1
233
300
350
400
500
600
m3 /h
14
18
21
24
30
36
VLR 30B - 20 FT
5,50
4,00
3 ~ 400/690 V
8,6
39
37
35
32,5
26,5
19
E6500020
VLR 30B - 30 FT
7,50
5,50
3 ~ 400/690 V
11,3
58
55
53
48
40
29
E6500030
7,50
3 ~ 400/690 V
14,7
78
74
70
65
53
38
E6500040
11,00
3 ~ 400/690 V
21,0
97
92
88
81
66
48
E6500050
11,00
3 ~ 400/690 V
21,0
117
110
105
97
79
58
E6500060
15,00
3 ~ 400/690 V
29,0
136
129
123
113
92
67
E6500070
15,00
3 ~ 400/690 V
29,0
155
147
140
130
106
77
E6500080
15,00
3 ~ 400/690 V
29,0
175
166
158
146
119
86
E6500090
18,50
3 ~ 400/690 V
35,0
194
184
175
162
132
96
E6500100
18,50
3 ~ 400/690 V
35,0
214
202
193
178
145
106
E6500110
22,00
3 ~ 400/690 V
42,0
233
221
210
194
158
115
39
Discharge head
in meters
E6500010
PRICE
VLR 30B
D2
L1
G 1/2 LOAD
Rp 3/8
Rp 3/8
DNA
DNM
A
35
B
G 1/2 LOAD
220
260
L1+L2
L2
15
N 4 HOLES
220
260
Net Weight
kg
Dimensions in mm
Model
DNA/
DNM
L1
L2
D1
D2
Pump- Electric
pump
end
VLR 30B - 20
65
588
312
105
320
136
193
160
170
48
78
VLR 30B - 30
65
680
350
105
320
150
220
300
190
56
102
VLR 30B - 40
65
752
350
105
320
150
220
300
190
59
109
VLR 30B - 50
65
856
856
105
320
228
316
350
222
70
155
VLR 30B - 60
65
1120
495
105
320
228
316
350
222
83
168
VLR 30B - 70
65
1192
495
105
320
228
316
350
222
86
178
VLR 30B - 80
65
1264
495
105
320
228
316
350
222
89
181
VLR 30B - 90
65
1336
495
105
320
228
316
350
222
93
185
65
1408
495
105
320
228
316
350
222
96
195
65
1480
495
105
320
228
316
350
222
99
198
65
1552
495
105
320
245
316
350
222
102
216
40
SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 60Bs are vertical multistage centrifugal pumps with "in line"
suction and delivery points directly connected to an electric motor.
They are not self-priming.
Design Features
- Impellers, diffusor and upper spacer, shaft, outer liner and coupling
guard in stainless steel AISI 304
- Electric pump base and head and coupling in cast iron
- Shaft protected by a tungsten carbide liner
- Mechanical seal in silicon carbide and carbon
(on request widia-widia)
- EPDM rubber O ring
- Supplied complete with counterflanges
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 20C to 120C
- Maximum operating pressure including suction head: 16 bar
- Minimum suction head:
please refer to the NPSH values with a safety margin of 0.5 m water
column
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general
CODE
Motor
Power
MODEL
VOLTAGE
HP
kW
Amp.
L/1
400
500
600
800 1000
1200
m3 /h
24
30
36
48
60
72
VLR 60B - 20 FT
7,50
5,50
3 ~ 400/690 V
11,3
33
32
30
25
19
12
E7500020
VLR 60B - 30 FT
10,00
7,50
3 ~ 400/690 V
14,7
51
48
45
38
28
17
E7500030
VLR 60B - 40 FT
15,00
11,00
3 ~ 400/690 V
21,0
67
63
60
51
38
23
E7500040
VLR 60B - 50 FT
20,00
15,00
3 ~ 400/690 V
29,0
84
80
75
63
48
28
E7500050
VLR 60B - 60 FT
20,00
15,00
3 ~ 400/690 V
29,0
102
96
90
76
58
35
E7500060
VLR 60B - 70 FT
25,00
18,50
3 ~ 400/690 V
35,0
118
112
105
88
67
E7500070
VLR 60B - 80 FT
30,00
22,00
3 ~ 400/690 V
42,0
135
128
120
102
77
41
Discharge head
in meters
E7500010
40
46
PRICE
VLR 60B
D2
L1
G 1/2 LOAD
Rp 3/8
Rp 3/8
DNM
DNA
35
B
G 1/2 LOAD
220
260
L1+L2
L2
15
N 4 HOLES
220
260
Net Weight
kg
Dimensions mm
Model
DNA/
DNM
L1
VLR 60B - 20
100
VLR 60B - 30
VLR 60B - 40
VLR 60B - 50
VLR 60B - 60
Pump- Electric
end
pump
L2
D1
D2
658
350
140
365
150
220
300
190
57
103
100
730
350
140
365
150
220
300
190
60
110
100
834
495
140
365
228
316
350
222
71
156
100
906
495
140
365
228
316
350
222
74
166
100
1170
495
140
365
228
316
350
222
87
179
VLR 60B - 70
100
1242
495
140
365
228
316
350
222
90
189
VLR 60B - 80
100
1314
495
140
365
245
316
350
222
94
208
42
SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLRI 2Bs (Version "A" with oval flanges) are vertical multistage
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Design Features
- Base, impellers, diffusors, intermediate chambers and outer liner in
stainless steel AISI 304
- Electric pump head and coupling in GG20 cast iron
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- EPDM rubber O ring
- The VLRI 2B, A version, are complete with 11/4" oval gas counterflanges
in steel AISI 316
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to 120C
- Maximum operating pressure: 16 bar
- Maximum inlet pressure: VLRI 2B- 30/2
= 6 bar
VLRI 2B- 30 - VLRI 2B-110 = 10 bar
VLRI 2B-130 - VLRI 2B-150 = 15 bar
- Minimum suction head:
please refer to the NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general
Motor
Power
MODEL
HP
kW
VOLTAGE
Amp.
F.
L/1
10
20
30
40
50
m /h
0,6
1,2
1,8
2,4
3,0
19
18
17
14
11
29
27
25
21
17
37
35
32
29
23
47
43
40
35
28
56
51
48
42
33
65
60
55
49
39
84
78
70
62
50
100
93
84
74
60
120
112
102
89
71
138
129
116
99
81
PRICE
Q
3
E2402010
E2402020
0,50
0,37
1 ~ 230 V
3 ~ 230/400 V
2,7
1,0 - 0,6
14
E2402030
E2402040
VLRI 2B- 30
VLRI 2B- 30
AM
AT
0,50
0,37
1 ~ 230 V
3 ~ 230/400 V
2,7
1,4 - 0,8
14
E2402050
E2402060
E2402070
E2402080
40
40
50
50
AM
AT
AM
AT
0,75
0,55
1 ~ 230 V
3 ~ 230/400 V
4,0
1,8 - 1,0
16
0,75
0,55
1 ~ 230 V
3 ~ 230/400 V
4,0
2,3 - 1,3
16
E2402090
E2402100
VLRI 2B- 60
VLRI 2B- 60
AM
AT
1,00
0,75
1 ~ 230 V
3 ~ 230/400 V
5,2
2,7 - 1,5
25
E2402110
E2402120
VLRI 2B- 70
VLRI 2B- 70
AM
AT
1,00
0,75
1 ~ 230 V
3 ~ 230/400 V
5,2
3,0 - 1,7
25
E2402130
E2402140
VLRI 2B- 90
VLRI 2B- 90
AM
AT
1,50
1,10
1 ~ 230 V
3 ~ 230/400 V
8,0
3,6 - 2,1
35
E2402150
E2402160
VLRI 2B-110 A M
VLRI 2B-110 A T
1,50
1,10
1 ~ 230 V
3 ~ 230/400 V
8,0
4,3 - 2,5
35
E2402170
E2402180
VLRI 2B-130
VLRI 2B-130
AM
AT
2,00
1,50
1 ~ 230 V
3 ~ 230/400 V
12,0
5,0 - 2,9
45
E2402190
E2402200
VLRI 2B-150
VLRI 2B-150
AM
AT
2,00
1,50
1 ~ 230 V
3 ~ 230/400 V
12,0
5,7 - 3,3
45
43
Discharge head
in meters
CODE
VLRI 2B
H
50
3/4"
22
64
100
156
160
22
65
3/8"
M 10x40
20
11/4"gas
104
180
210
13,5
n. 4 holes
Net Weight
kg
Dimensions mm
Model
VLRI 2B - 30/2 A
VLRI 2B - 30 A
VLRI 2B - 40 A
VLRI 2B - 50 A
VLRI 2B - 60 A
VLRI 2B - 70 A
VLRI 2B - 90 A
VLRI 2B - 110 A
VLRI 2B - 130 A
VLRI 2B - 150 A
263
263
281
299
321
339
375
411
466
502
215
215
215
215
245
245
245
245
255
255
478
478
496
514
566
584
620
656
721
757
158
158
158
158
170
170
170
170
180
180
168
168
168
168
203
203
203
203
205
205
44
20
21
23
25
26
33
34
36
37
43
SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLRI 2Bs (Version "F" with round flanges) are vertical multistage
electric centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Design Features
- Base, impellers, diffusors, intermediate chambers and outer liner in
stainless steel AISI 304
- Electric pump head and coupling in GG20 cast iron
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- EPDM rubber O ring
- For the version "F" VLRI, round DN 32 counterflanges on request
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to 120C
- Maximum operating pressure:
25 bar (max. pumped liquid temperature 40 C)
21 bar (max. pumped liquid temperature 120 C)
- Maximum inlet pressure: VLRI 2B- 30/2
VLRI 2B- 30 - VLRI 2B-110
VLRI 2B- 130 - VLRI 2B-260
- Minimum suction head:
please refer to the NPSH values with a safety margin
= 6 bar
= 10 bar
= 15 bar
of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general
Motor
Power
MODEL
VOLTAGE
HP
kW
E2400010
E2400020
0,50
0,37
E2400030
E2400040
VLRI 2B- 30
VLRI 2B- 30
FM
FT
0,50
E2400050
E2400060
VLRI 2B- 40
VLRI 2B- 40
FM
FT
E2400070
E2400080
VLRI 2B- 50
VLRI 2B- 50
E2400090
E2400100
Amp.
F.
1 ~ 230 V
2,7
3 ~ 230400 V
1,0 - 0,6
0,37
1 ~ 230 V
3 ~ 230400 V
2,7
1,4 - 0,8
14
0,75
0,55
1 ~ 230 V
3 ~ 230400 V
4,0
1,8 - 1,0
16
FM
FT
0,75
0,55
1 ~ 230 V
3 ~ 230400 V
4,0
2,3 - 1,3
16
VLRI 2B- 60
VLRI 2B- 60
FM
FT
1,00
0,75
1 ~ 230 V
3 ~ 230400 V
5,2
2,7 - 1,5
25
E2400110
E2400120
VLRI 2B- 70
VLRI 2B- 70
FM
FT
1,00
0,75
25
E2400130
E2400140
VLRI 2B- 90
VLRI 2B- 90
FM
FT
1,50
E2400150
E2400160
VLRI 2B-110
VLRI 2B-110
FM
FT
E2400170
E2400180
VLRI 2B-130
VLRI 2B-130
E2400190
E2400200
L/1
10
20
30
40
50
m3 /h
0,6
1,2
1,8
2,4
3,0
19
18
17
14
11
29
27
25
21
17
37
35
32
29
23
47
43
40
35
28
56
51
48
42
33
65
60
55
49
39
84
78
70
62
50
100
93
84
74
60
120
112
102
89
71
138
129
116
99
81
PRICE
14
Discharge head
in meters
CODE
1 ~ 230 V
5,2
3 ~ 230400 V
3,0 - 1,7
1,10
1 ~ 230 V
3 ~ 230400 V
8,0
3,6 - 2,1
35
1,50
1,10
1 ~ 230 V
3 ~ 230400 V
8,0
4,3 - 2,5
35
FM
FT
2,00
1,50
1 ~ 230 V
3 ~ 230400 V
12,0
5,0 - 2,9
45
VLRI 2B-150
VLRI 2B-150
FM
FT
2,00
1,50
1 ~ 230 V
3 ~ 230400 V
12,0
5,7 - 3,3
45
E2400210
VLRI 2B-180
FT
3,00
2,20
3 ~ 230400 V
7,2 - 4,1
166
155
141
122
99
E2400220
VLRI 2B-220
FT
3,00
2,20
3 ~ 230400 V
8,7 - 5,0
199
185
168
145
118
E2400230
VLRI 2B-260
FT
4,00
3,00
3 ~ 230400 V
11,4 - 6,6
232
220
200
173
141
45
VLRI 2B
H
3/8"
3/8"
75
3/4"
60
100
156
250
3/8"
20
32
78
100
140
n4 holes 18
104
180
210
13,5
n. 4 holes
Net Weight
kg
Dimensions mm
Model
VLRI 2B - 30/2 F
VLRI 2B - 30 F
VLRI 2B - 40 F
VLRI 2B - 50 F
VLRI 2B - 60 F
VLRI 2B - 70 F
VLRI 2B - 90 F
VLRI 2B - 110 F
VLRI 2B - 130 F
VLRI 2B - 150 F
VLRI 2B - 180 F
VLRI 2B - 220 F
VLRI 2B - 260 F
250
250
268
286
308
326
362
388
453
489
568
640
716
215
215
215
215
245
245
245
245
255
255
280
280
300
465
465
483
501
553
571
607
633
708
744
848
920
1016
158
158
158
158
170
170
170
170
180
180
180
180
196
168
168
168
168
203
203
203
203
205
205
205
205
235
46
26
27
29
31
32
39
39
42
43
49
49
61
63
SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLR 4s (Version "A" with oval flanges) are vertical multistage electric
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Design Features
- Base, impellers, diffusors, intermediate chambers and outer liner in
stainless steel AISI 304
- Electric pump head and coupling in GG20 cast iron
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- EPDM rubber O ring
- The VLRI 4, version A, are complete with 11/4" oval gas counterflanges
in steel AISI 316
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to 120C
- Maximum operating pressure: 16 bar
- Maximum inlet pressure:
VLRI 4- 20
=
VLRI 4- 30 - VLRI 4-100 =
VLRI 4-120 - VLRI 4-160 =
- Minimum suction head:
please refer to the NPSH values with a safety margin of
6 bar
10 bar
15 bar
0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general
Motor
Power
MODEL
HP
kW
VOLTAGE
Amp.
F.
E3602010
E3602020
VLRI 4- 20 A M
VLRI 4- 20 A T
0,50
0,37
1 ~ 230 V
3 ~ 230400 V
2,7
1,7 - 1,0
14
E3602030
E3602040
VLRI 4- 30 A M
VLRI 4- 30 A T
0,75
0,55
1 ~ 230 V
3 ~ 230400 V
4,0
2,5 - 1,4
16
E3602050
E3602060
E3602070
E3602080
1,00
0,75
1 ~ 230 V
3 ~ 230400 V
5,2
3,3 - 1,9
25
1,50
1,10
1 ~ 230 V
3 ~ 230400 V
8,0
4,3 - 2,5
35
E3602090
E3602100
VLRI 4- 60 A M
VLRI 4- 60 A T
1,50
1,10
1 ~ 230 V
3 ~ 230400 V
8,0
4,3 - 2,5
35
E3602110
E3602120
VLRI 4- 80/7 A M
VLRI 4- 80/7 A T
2,00
1,50
1 ~ 230 V
3 ~ 230400 V
12
5,9 - 3,4
45
E3602130
E3602140
VLRI 4- 80 A M
VLRI 4- 80 A T
2,00
1,50
45
E3602150
VLRI 4-100 A T
3,00
E3602160
VLRI 4-120 A T
E3602170
E3602180
40
40
50
50
A
A
A
A
M
T
M
T
L/1
40
60
80
100
120
m3 /h
2,4
3,6
4,8
6,0
7,2
19
17
15
13
28
25
22
19
13
36
33
29
25
18
44
42
37
31
23
53
50
44
38
27
61
58
51
44
32
71
67
59
50
37
PRICE
Discharge head
in meters
CODE
1 ~ 230 V
12
3 ~ 230400 V
5,9 - 3,4
2,20
3 ~ 230400 V
8,3 - 4,8
90
82
72
61
46
3,00
2,20
3 ~ 230400 V
8,3 - 4,8
107
99
87
73
54
VLRI 4-140 A T
4,00
3,00
3 ~ 230400 V
10,9 - 6,3
124
116
102
85
63
VLRI 4-160 A T
4,00
3,00
3 ~ 230400 V
10,9 - 6,3
142
132
116
97
72
47
VLRI 4
H
50
3/4"
22
64
100
156
160
22
65
3/8"
M 10x40
20
11/4"gas
104
180
210
13,5
n. 4 holes
Net Weight
kg
Dimensions mm
Model
VLRI 4 - 20 A
VLRI 4 - 30 A
VLRI 4 - 40 A
VLRI 4 - 50 A
VLRI 4 - 60 A
VLRI 4 - 80/7 A
VLRI 4 - 80 A
VLRI 4 - 100 A
VLRI 4 - 120 A
VLRI 4 - 140 A
VLRI 4 - 160 A
263
290
321
348
375
448
448
502
556
614
668
215
215
245
245
245
255
255
280
280
300
300
478
505
566
593
620
703
703
782
836
914
968
158
158
170
170
170
180
180
180
180
196
196
168
168
203
203
203
205
205
205
205
235
235
48
20
21
23
25
26
33
34
36
37
43
43
SURFACE PUMPS
VERTICAL MULTISTAGE
CENTRIFUGAL PUMPS
The VLRI 4s (Version "F" with round flanges) are vertical multistage
electric centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Design Features
- Base, impellers, diffusors, intermediate chambers and outer liner in
stainless steel AISI 304
- Electric pump head and coupling in GG20 cast iron
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- EPDM rubber O ring
- For the version "F" VLRI, round DN 32 counterflanges on request
Motor
- Asynchronous electric three-phase motor with enclosed stator and
external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to 120C
- Maximum operating pressure:
25 bar (max. pumped liquid temperature
40 C)
21 bar (max. pumped liquid temperature 120 C)
- Maximum inlet pressure:
VLRI 4- 20
= 6 bar
VLRI 4- 30 - VLRI 4-100 = 10 bar
VLRI 4-120 - VLRI 4-260 = 15 bar
- Minimum suction head:
please refer to the NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general
CODE
Motor
Power
MODEL
HP
kW
E3600010
E3600020
VLRI 4- 20
VLRI 4- 20
FM
FT
0,50
0,37
E3600030
E3600040
VLRI 4- 30
VLRI 4- 30
FM
FT
0,75
E3600050
E3600060
VLRI 4- 40
VLRI 4- 40
FM
FT
1,00
E3600070
E3600080
VLRI 4- 50
VLRI 4- 50
FM
FT
E3600090
E3600100
VLRI 4- 60
VLRI 4- 60
FM
FT
E3600110
E3600120
VLRI 4- 80/7 F M
VLRI 4- 80/7 F T
2,00
1,50
E3600130
E3600140
VLRI 4- 80
VLRI 4- 80
FM
FT
2,00
E3600150
VLRI 4-100
FT
E3600160
VLRI 4-120
E3600170
VOLTAGE
Amp.
F. Q
L/1
40
60
80
100
120
m3 /h
2,4
3,6
4,8
6,0
7,2
19
17
15
13
28
25
22
19
13
36
33
29
25
18
44
42
37
31
23
53
50
44
38
27
61
58
51
44
32
71
67
59
50
37
90
82
72
61
46
107
99
87
73
54
PRICE
1 ~ 230 V
2,7
3 ~ 230400 V
1,7 - 1,0
0,55
1 ~ 230 V
3 ~ 230400 V
4,0
2,5 - 1,4
16
0,75
1 ~ 230 V
3 ~ 230400 V
5,2
3,3 - 1,9
25
1,50
1,10
1 ~ 230 V
3 ~ 230400 V
8,0
4,3 - 2,5
35
1,50
1,10
1 ~ 230 V
3 ~ 230400 V
8,0
4,3 - 2,5
35
1 ~ 230 V
12
45
3 ~ 230400 V
5,9 - 3,4
1,50
1 ~ 230 V
3 ~ 230400 V
12
5,9 - 3,4
3,00
2,20
3 ~ 230400 V
8,3 - 4,8
FT
3,00
2,20
3 ~ 230400 V
8,3 - 4,8
VLRI 4-140
FT
4,00
3,00
3 ~ 230400 V
10,9 - 6,3
124
116
102
85
63
E3600180
VLRI 4-160
FT
4,00
3,00
3 ~ 230400 V
10,9 - 6,3
142
132
116
97
72
E3600250
E3600190
E3600260
E3600200
VLRI 4-190
VLRI 4-190
FT
FT
5,50
4,00
170
157
138
114
86
VLRI 4-220
VLRI 4-220
FT
FT
5,50
196
181
160
131
101
E3600230
E3600210
VLRI 4-240
VLRI 4-240
FT
FT
213
198
175
143
110
E3600220
E3600240
VLRI 4-260
VLRI 4-260
FT
FT
230
231
189
156
120
3 ~ 230400 V
3 ~ 400690 V
13,8 - 8,0
4,00
3 ~ 230400 V
3 ~ 400690 V
13,8 - 8,0
7,50
5,50
3 ~ 230400 V
3 ~ 400690 V
12,4 - 21,5
7,50
5,50
3 ~ 230400 V
3 ~ 400690 V
12,4 - 21,5
49
45
Discharge head
in meters
14
VLRI 4
H
3/8"
3/8"
75
3/4"
60
100
156
250
3/8"
20
32
78
100
140
n4 holes 18
104
180
210
13,5
n. 4 holes
Net Weight
kg
Dimensions mm
Model
VLRI 4 - 20 F
VLRI 4 - 30 F
VLRI 4 - 40 F
VLRI 4 - 50 F
VLRI 4 - 60 F
VLRI 4 - 80/7 F
VLRI 4 - 80 F
VLRI 4 - 100 F
VLRI 4 - 120 F
VLRI 4 - 140 F
VLRI 4 - 160 F
VLRI 4 - 190 F
VLRI 4 - 220 F
VLRI 4 - 240 F
VLRI 4 - 260 F
250
277
308
335
362
435
435
489
543
601
655
761
842
923
977
215
215
245
245
245
255
255
280
280
300
300
325
325
390
390
465
492
553
580
607
690
690
769
823
901
955
1086
1167
1313
1367
158
158
170
170
170
180
180
180
180
196
196
218
218
300
300
168
168
203
203
203
205
205
205
205
235
235
256
256
350
350
50
26
27
29
31
32
39
39
42
43
49
49
61
63
87
89
SURFACE PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX 2Bs (Version A with oval flanges) are vertical multistage
electric centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Entirely in AISI 316 stainless steel for sea water and special applications.
Design Features
- Impellers, shaft, diffusors, intermediate chambers, outer liner and pump
base in AISI 316 stainless steel
- Pump head in GG20 cast iron
- EPDM rubber O ring
- Complete with 11/4" oval gas counterflanges
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure: 16 bar
- Maximum inlet pressure:
VLRX 2B- 30/2
VLRX 2B- 30 - VLRX 2B-110
VLRX 2B-130 - VLRX 2B-150
- Minimum suction head:
please refer to the NPSH values with a safety margin
= 6 bar
= 10 bar
= 15 bar
of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer
MODEL
Motor
Power
HP
kW
VOLTAGE
F.
Amp.
L/1'
VLRX 2B - 30/2 A M
VLRX 2B - 30/2 A T
0,5
0,37
1 ~ 230 V
3 ~ 230 400 V
2,7
1 - 0,6
14
E2632103
E2631003
VLRX 2B - 30 A M
VLRX 2B - 30 A T
0,5
0,37
1 ~ 230 V
3 ~ 230 400 V
2,7
1,4 - 0,8
14
E2632104
E2631004
VLRX 2B - 40 A M
VLRX 2B - 40 A T
0,75
0,55
1 ~ 230 V
3 ~ 230 400 V
4
1,8 - 1
16
E2632105
E2631005
VLRX 2B - 50 A M
VLRX 2B - 50 A T
0,75
0,55
1 ~ 230 V
3 ~ 230 400 V
4
2,3 - 1,3
16
E2632106
E2631006
VLRX 2B - 60 A M
VLRX 2B - 60 A T
0,75
1 ~ 230 V
3 ~ 230 400 V
5,2
2,7 - 1,5
25
E2632107
E2631007
VLRX 2B - 70 A M
VLRX 2B - 70 A T
0,75
1 ~ 230 V
3 ~ 230 400 V
5,2
3 - 1,7
25
E2632108
E2631008
VLRX 2B - 90 A M
VLRX 2B - 90 A T
1,5
1,1
1 ~ 230 V
3 ~ 230 400 V
8
3,6 - 2,1
35
E2632110
E2631010
VLRX 2B - 110 A M
VLRX 2B - 110 A T
1,5
1,1
1 ~ 230 V
3 ~ 230 400 V
8
4,3 - 2,5
35
E2632112
E2631012
VLRX 2B - 130 A M
VLRX 2B - 130 A T
1,5
1 ~ 230 V
3 ~ 230 400 V
12
5 - 2,9
45
E2632114
E2631014
VLRX 2B - 150 A M
VLRX 2B - 150 A T
1,5
1 ~ 230 V
3 ~ 230 400 V
12
5,7 - 3,3
45
51
20
30
40
50
0,6
1,2
1,8
2,4
19
18
17
14
11
29
27
25
21
17
37
35
32
29
23
47
43
40
25
28
56
51
48
42
33
65
60
55
49
39
84
78
70
62
50
100
93
84
74
60
89
71
99
81
PRICE
3
m /h
E2632102
E2631002
10
Discharge head
in meters
CODE
VLRX 2B
H
50
3/4"
22
64
100
156
160
22
65
3/8"
M 10x40
20
11/4"gas
104
180
210
13,5
n. 4 holes
VLRX 2B - 30/2 A
VLRX 2B - 30 A
VLRX 2B - 40 A
VLRX 2B - 50 A
VLRX 2B - 60 A
VLRX 2B - 70 A
VLRX 2B - 90 A
VLRX 2B - 110 A
VLRX 2B - 130 A
VLRX 2B - 150 A
Net Weight
kg
Dimensions mm.
Model
A
237
237
255
273
297
315
351
387
439
475
216
216
216
216
241
241
241
241
260
260
453
453
471
488
538
556
592
628
699
735
141
141
141
141
158
158
158
158
176
176
101
101
101
101
115
115
115
115
115
115
52
20
21
23
25
26
33
33
36
37
43
SURFACE PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX 2Bs (Version F with round flanges) are vertical multistage
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Entirely in AISI 316 stainless steel for sea water and special applications.
Design Features
- Impellers, shaft, diffusors, intermediate chambers, outer liner and pump
base in AISI 316 stainless steel
- Pump head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- For the version "F" VLRX, round DN 32 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation;
- level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure: 25 bar
- Maximum head pressure:
VLRX 2B- 30/2
VLRX 2B- 30 - VLRX 2B-110
VLRX 2B-130 - VLRX 2B-260
- Minimum suction head:
please refer to the NPSH values with a safety margin
= 6 bar
= 10 bar
= 15 bar
of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer
CODE
Motor
Power
MODEL
HP
VOLTAGE
Amp.
F.
kW
L/1
10
20
30
40
50
m3 /h
0,6
1,2
1,8
2,4
3,0
19
18
17
14
11
29
27
25
21
17
37
35
32
29
23
47
43
40
35
28
56
51
48
42
33
65
60
55
49
39
84
78
70
62
50
100
93
84
74
60
120
112
102
89
71
138
129
116
99
81
PRICE
1 ~ 230 V
2,7
3 ~ 230400 V
1,0 - 0,6
FM
F T 0,50 0,37
1 ~ 230 V
3 ~ 230400 V
2,7
1,4 - 0,8
14
FM
F T 0,75 0,55
1 ~ 230 V
3 ~ 230400 V
4,0
1,8 - 1,0
16
FM
0,55
F T 0,75
1 ~ 230 V
3 ~ 230400 V
4,0
2,3 - 1,3
16
FM
F T 1,00 0,75
1 ~ 230 V
3 ~ 230400 V
5,2
2,7 - 1,5
25
FM
F T 1,00 0,75
1 ~ 230 V
5,2
25
3 ~ 230400 V
3,0 - 1,7
FM
F T 1,50 1,10
1 ~ 230 V
3 ~ 230400 V
8,0
3,6 - 2,1
35
FM
F T 1,50 1,10
1 ~ 230 V
3 ~ 230400 V
8,0
4,3 - 2,5
35
FM
2,00 1,50
FT
1 ~ 230 V
3 ~ 230400 V
12,0
5,0 - 2,9
45
FM
2,00 1,50
FT
1 ~ 230 V
3 ~ 230400 V
12,0
5,7 - 3,3
45
FT
3,00 2,20
3 ~ 230400 V
7,2 - 4,1
166
155
141
122
99
FT
3,00 2,20
3 ~ 230400 V
8,7 - 5,0
199
185
168
145
118
FT
4,00 3,00
3 ~ 230400 V
11,4 - 6,6
232
220
200
173
141
53
Discharge head
in meters
14
VLRX 2B
H
3/8"
3/8"
75
3/4"
60
100
156
250
3/8"
20
32
78
100
140
n4 holes 18
104
180
210
13,5
n. 4 holes
Net Weight
kg
Dimensions mm
Model
VLRX 2B - 30/2 F
VLRX 2B - 30 F
VLRX 2B - 40 F
VLRX 2B - 50 F
VLRX 2B - 60 F
VLRX 2B - 70 F
VLRX 2B - 90 F
VLRX 2B - 110 F
VLRX 2B - 130 F
VLRX 2B - 150 F
VLRX 2B - 180 F
VLRX 2B - 220 F
VLRX 2B - 260 F
250
250
268
286
308
326
362
388
453
489
568
640
716
215
215
215
215
245
245
245
245
255
255
280
280
300
465
465
483
501
553
571
607
633
708
744
848
920
1016
158
158
158
158
170
170
170
170
180
180
180
180
196
168
168
168
168
203
203
203
203
205
205
205
205
235
54
26
27
29
31
32
39
39
42
43
49
49
61
63
SURFACE PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX 4s (Version A with oval flanges) are vertical multistage
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming.
Entirely in AISI 316 stainless steel for sea water and special applications.
Design Features
- Impellers, shaft, diffusors, intermediate chambers, outer liner and pump
base in AISI 316 stainless steel
- Pump head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- Complete with 11/4" oval gas counterflanges
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure: 16 bar
- Maximum inlet pressure:
VLRX 4- 20
VLRX 4- 30 - VLRX 4-100
VLRX 4-120 - VLRX 4-160
- Minimum suction head:
please refer to the NPSH values with a safety margin
= 6 bar
= 10 bar
= 15 bar
of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer in general
CODE
Motor
Power
MODEL
HP
kW
VOLTAGE
Amp.
F.
L/1'
40
60
80
m3/h
2,4
3,6
4,8
7,2
19
17
15
13
28
25
22
19
13
36
33
29
25
18
44
42
37
31
23
53
50
44
38
27
61
58
51
44
32
71
67
59
50
37
100 120
PRICE
VLRX 4 - 20 A M
VLRX 4 - 20 A T
0,5
0,37
1 ~ 230 V
3 ~ 230 400 V
2,7
1,73-1
14
E3632103
E3631003
VLRX 4 - 30 A M
VLRX 4 - 30 A T
0,75
0,55
1 ~ 230 V
3 ~ 230 400 V
4
2,5-1,45
16
E3632104
E3631004
VLRX 4 - 40 A M
VLRX 4 - 40 A T
0,75
1 ~ 230 V
3 ~ 230 400 V
5,2
3,3-1,9
25
E3632105
E3631005
VLRX 4 - 50 A M
VLRX 4 - 50 A T
1,5
1,1
1 ~ 230 V
3 ~ 230 400 V
8
4,3-2,5
35
E3632106
E3631006
VLRX 4 - 60 A M
VLRX 4 - 60 A T
1,5
1,1
1 ~ 230 V
3 ~ 230 400 V
8
4,3-2,5
35
E3632107
E3631007
VLRX 4 - 80/7 A M
VLRX 4 - 80/7 A T
1,5
1 ~ 230 V
3 ~ 230 400 V
12
5,9-3,4
45
E3632108
E3631008
VLRX 4 - 80 A M
VLRX 4 - 80 A T
1,5
1 ~ 230 V
3 ~ 230 400 V
12
5,9-3,4
45
E3631010
VLRX 4 - 100 A T
2,2
3 ~ 230 400 V
8,3-4,8
90
82
72
61
46
E3631012
VLRX 4 - 120 A T
2,2
3 ~ 230 400 V
8,3-4,8
107
99
87
73
54
E3631014
VLRX 4 - 140 A T
3 ~ 230 400 V
10,9-6,3
85
63
E3631016
VLRX 4 - 160 A T
3 ~ 230 400 V
10,9-6,3
97
72
55
Discharge head
in meters
E3632102
E3631002
VLRX 4
50
3/4"
22
64
100
156
160
22
65
3/8"
M 10x40
20
11/4"gas
104
180
210
13,5
n. 4 holes
VLRX 4 - 20 A
VLRX 4 - 30 A
VLRX 4 - 40 A
VLRX 4 - 50 A
VLRX 4 - 60 A
VLRX 4 - 80/7 A
VLRX 4 - 80 A
VLRX 4 - 100 A
VLRX 4 - 120 A
VLRX 4 - 140 A
VLRX 4 - 160 A
Net Weight
kg
Dimensions mm.
Model
A
235
262
289
316
347
401
401
455
528
636
636
215
215
237
237
237
277
277
277
277
323
323
450
477
526
553
584
678
678
732
805
959
959
141
141
158
158
158
179
179
179
179
197
197
115
115
142
142
142
145
145
145
145
165
165
56
20
21
23
25
26
33
33
36
37
43
43
SURFACE PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX 4s (Version F with round flanges) are vertical multistage
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming. Entirely in AISI
316 stainless steel for sea water and special applications.
Design Features
- Impellers, shaft, diffusors, intermediate chambers, outer liner and pump
base in AISI 316 stainless steel
- Pump head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- For the version "F" VLRXs, round DN 32 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure: 25 bar (max. liquid temperature 40 C)
- Maximum inlet pressure:
VLRX 4- 20
= 6 bar
VLRX 4- 30 - VLRX 4-100
= 10 bar
VLRX 4-120 - VLRX 4-260
= 15 bar
- Minimum suction head:
Please refer to NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer
CODE
Motor
Power
MODEL
HP
VOLTAGE
Amp.
F. Q
kW
E3730010 VLRX 4- 20
E3730020 VLRX 4- 20
FM
FT
0,50 0,37
E3730030 VLRX 4- 30
E3730040 VLRX 4- 30
FM
FT
E3730050 VLRX 4- 40
E3730060 VLRX 4- 40
FM
FT
E3730070 VLRX 4- 50
E3730080 VLRX 4- 50
E3730090 VLRX 4- 60
E3730100 VLRX 4- 60
1 ~ 230 V
2,7
3 ~ 230400 V
1,7 - 1,0
0,75 0,55
1 ~ 230 V
3 ~ 230400 V
4,0
2,5 - 1,4
16
1,00 0,75
1 ~ 230 V
3 ~ 230400 V
5,2
3,3 - 1,9
25
FM
FT
1,50 1,10
1 ~ 230 V
3 ~ 230400 V
8,0
4,3 - 2,5
35
FM
FT
1,50 1,10
1 ~ 230 V
3 ~ 230400 V
8,0
4,3 - 2,5
35
1 ~ 230 V
12
45
3 ~ 230400 V
5,9 - 3,4
L/1
40
60
80
100
120
m3 /h
2,4
3,6
4,8
6,0
7,2
19
17
15
13
28
25
22
19
13
36
33
29
25
18
44
42
37
31
23
53
50
44
38
27
61
58
51
44
32
71
67
59
50
37
90
82
72
61
46
107
99
87
73
54
PRICE
14
2,00 1,50
E3730130 VLRX 4- 80
E3730140 VLRX 4- 80
FM
FT
2,00 1,50
1 ~ 230 V
3 ~ 230400 V
12
5,9 - 3,4
FT
3,00 2,20
3 ~ 230400 V
8,3 - 4,8
FT
3,00 2,20
3 ~ 230400 V
8,3 - 4,8
FT
4,00 3,00
3 ~ 230400 V
10,9 - 6,3
124
116
102
85
63
FT
4,00 3,00
3 ~ 230400 V
10,9 - 6,3
142
132
116
97
72
VLRX 4-190
VLRX 4-190
FT
FT
5,50 4,00
170
157
138
114
86
VLRX 4-220
VLRX 4-220
FT
FT
196
181
160
131
101
VLRX 4-240
VLRX 4-240
213
198
175
143
110
230
231
189
156
120
E3730190
E3730250
E3730200
E3730260
E3730210
E3730230
3 ~ 230400 V
3 ~ 400690 V
13,8 - 8,0
5,50 4,00
3 ~ 230400 V
3 ~ 400690 V
13,8 - 8,0
FT
FT
7,50 5,50
3 ~ 230400 V
3 ~ 400690 V
12,4 - 21,5
FT
FT
7,50 5,50
3 ~ 230400 V
3 ~ 400690 V
12,4 - 21,5
57
Discharge head
in meters
45
VLRX 4
H
3/8"
3/8"
75
3/4"
60
100
156
250
3/8"
20
32
78
100
140
n4 holes 18
104
180
210
13,5
n. 4 holes
Net Weight
kg
Dimensions mm
Model
VLRX 4 - 20 F
VLRX 4 - 30 F
VLRX 4 - 40 F
VLRX 4 - 50 F
VLRX 4 - 60 F
VLRX 4 - 80/7 F
VLRX 4 - 80 F
VLRX 4 - 100 F
VLRX 4 - 120 F
VLRX 4 - 140 F
VLRX 4 - 160 F
VLRX 4 - 190 F
VLRX 4 - 220 F
VLRX 4 - 240 F
VLRX 4 - 260 F
250
277
308
335
362
435
435
489
543
601
655
761
842
923
977
215
215
245
245
245
255
255
280
280
300
300
325
325
390
390
465
492
553
580
607
690
690
769
823
901
955
1086
1167
1313
1367
158
158
170
170
170
180
180
180
180
196
196
218
218
300
300
168
168
203
203
203
205
205
205
205
235
235
256
256
350
350
58
26
27
29
31
32
39
39
42
43
49
49
61
63
87
89
SURFACE PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX 8s (Version F with round flanges) are vertical multistage
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming. Entirely in AISI
316 stainless steel for sea water and special applications.
Design Features
- Impellers, shaft, diffusors, intermediate chambers, outer liner and pump
base in AISI 316 stainless steel
- Pump head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- For the version "F" VLRXs, round DN 32 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure: 25 bar (max. liquid temperature 40 C)
23 bar (max. liquid temperature 120 C)
- Maximum inlet pressure:
VLRX 8-20 - VLRX 8-30
= 6 bar
VLRX 8-40 - VLRX 8-200
= 10 bar
- Minimum suction head:
Please refer to NPSH values with a safety margin of 0.5 m
Applications
Water supply - Pressure increase systems - Irrigation - High pressure
washes - Firefighting systems - Boiler supply - Liquid transfer
CODE
Motor
Power
MODEL
HP
kW
VOLTAGE
Amp.
F. Q
L/1
50
100
150
175
200
m /h
10,5
12
PRICE
3
VLRX 8 - 20 F M
VLRX 8 - 20 F T
0,75
1 ~ 230 V
3 ~ 230 400 V
5,2
3,3-1,9
25
21
20
18
15
13
E4730030
E4730040
VLRX 8 - 30 F M
VLRX 8 - 30 F T
1,5
1,1
1 ~ 230 V
3 ~ 230 400 V
8
4,3-2,5
35
32
30
27
23
19
E4730050
E4730060
VLRX 8 - 40 F M
VLRX 8 - 40 F T
1,5
1 ~ 230 V
3 ~ 230 400 V
12
5,9-3,4
45
42
40
35
30
26
E4730070
VLRX 8 - 50 F T
2,2
3 ~ 230 400 V
8,8-5,1
53
50
44
38
32
E4730080
VLRX 8 - 60 F T
2,2
3 ~ 230 400 V
8,8-5,1
64
60
52
45
39
E4730090
VLRX 8 - 80 F T
3 ~ 230 400 V
11,8-6,8
85
80
70
60
52
E4730100
E4730110
VLRX 8 - 100 F T
VLRX 8 - 100 F T
5,5
3 ~ 230 400 V
3 ~ 400 690 V
16,8-9,7
106
100
88
76
65
E4730120
E4730130
VLRX 8 - 120 F T
VLRX 8 - 120 F T
5,5
3 ~ 230 400 V
3 ~ 400 690 V
16,8-9,7
127
119
104
90
77
E4730140
E4730150
VLRX 8 - 140 F T
VLRX 8 - 140 F T
7,5
5,5
3 ~ 230 400 V
3 ~ 400 690 V
21,5-12,4
149
130
122
105
92
E4730160
E4430170
VLRX 8 - 160 F T
VLRX 8 - 160 F T
7,5
5,5
3 ~ 230 400 V
3 ~ 400 690 V
21,5-12,4
171
160
138
120
104
E4730180
E4730190
VLRX 8 - 180 F T
VLRX 8 - 180 F T
10
7,5
3 ~ 230 400 V
3 ~ 400 690 V
28-16,4
193
181
160
135
120
E4730200
E4730210
VLRX 8 - 200 F T
VLRX 8 - 200 F T
10
7,5
3 ~ 230 400 V
3 ~ 400 690 V
28-16,4
214
200
175
153
132
59
Discharge head
in meters
E4730010
E4730020
VLRX 8
Version with round flanges
PN10 DIN 2534/ISO 7005-2
80
3/4"
13,5 n4 holes
77
130
190
280
110
150
1B
48
66,5
19
215
245
3/4"
D3
Net Weight
kg
Dimensions mm
80
Model
13,5 n4 holes
77
130
190
280
110
150
48
1B
215
245
66,5
19
VLRX 8 - 20 F
VLRX 8 - 30 F
VLRX 8 - 40 F
VLRX 8 - 50 F
VLRX 8 - 60 F
VLRX 8 - 80 F
VLRX 8 - 100 F
VLRX 8 - 120 F
VLRX 8 - 140 F
VLRX 8 - 160 F
VLRX 8 - 180 F
VLRX 8 - 200 F
D3
745
805
865
925
237
237
265
265
265
315
335
335
385
385
385
385
1130
1190
1250
1310
160
160
185
185
185
200
200
200
260
260
260
260
131
131
130
130
130
140
140
140
185
185
185
185
300
300
300
300
60
33
35
43
45
46
54
55
59
80
81
85
86
SURFACE PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL
PUMPS IN AISI 316 STAINLESS STEEL
The VLRX 16s (Version F with round flanges) are vertical multistage
centrifugal pumps with "in line" suction and delivery points directly
connected to an electric motor. They are not self-priming. Entirely in AISI
316 stainless steel for sea water and special applications.
Design Features
- Impellers, shaft, diffusors, intermediate chambers, outer liner and pump
base in AISI 316 stainless steel
- Pump head in GG20 cast iron
- EPDM rubber O ring
- Mechanical seal with tungsten carbide primary and secondary ring,
EPDM O-ring
- For the version "F" VLRXs, round DN 32 counterflanges on request
Motor
- Asynchronous electric motor with enclosed stator and external ventilation
- Main dimensions are in accordance with the provisions of DIN and IEC
standards
- Class F insulation
- Level of protection IP 55
- Maximum environmental temperature 40 C
- Speed of rotation 2900 rpm
Usage Limitations
- Liquid temperature from - 15C to +120C
- Maximum operating pressure:
VLRX 16/30-2 - VLRX 16/80 16 bar
VLRX 16/100 - VLRX 16/160 25 bar
VLRX16/100 - VLRX 16/160 23 bar
( max temp 85 )
( max temp 120 )
= 6 bar
= 10bar
CODE
MODEL
Motor
Power
VOLTAGE
Amp.
L/1
100
200
250
300
350
m3 /h
12
15
18
21
PRICE
kW
2,2
3 ~ 230 400 V
8,8-5,1
29
27
26
22
18
E5730020 VLRX 16 - 30 F T
3 ~ 230 400 V
11,8-6,8
43
40
37
32
27
E5730030 VLRX 16 - 40 F T
E5730040 VLRX 16 - 40 F T
5,5
3 ~ 230 400 V
3 ~ 400 690 V
16,8-9,7
58
54
52
44
37
E5730050 VLRX 16 - 50 F T
E5730060 VLRX 16 - 50 F T
7,5
5,5
3 ~ 230 400 V
3 ~ 400 690 V
21,5-12,4
72
68
65
56
46
E5730070 VLRX 16 - 60 F T
E5730080 VLRX 16 - 60 F T
7,5
5,5
3 ~ 230 400 V
3 ~ 400 690 V
21,5-12,4
87
81
78
68
58
E5730090 VLRX 16 - 70 F T
E5730100 VLRX 16 - 70 F T
10
7,5
3 ~ 230 400 V
3 ~ 400 690 V
28-16,4
101
95
90
80
67
E5730110 VLRX 16 - 80 F T
E5730120 VLRX 16 - 80 F T
10
7,5
3 ~ 230 400 V
3 ~ 400 690 V
28-16,4
116
108
102
92
76
15
11
3 ~ 230 400 V
3 ~ 400 690 V
40-23,5
145
136
130
118
98
15
11
3 ~ 230 400 V
3 ~ 400 690 V
40-23,5
174
163
156
140
118
20
15
3 ~ 230 400 V
3 ~ 400 690 V
50-29
204
190
184
163
140
20
15
3 ~ 230 400 V
3 ~ 400 690 V
50-29
232
220
208
188
159
61
Discharge head
in meters
HP
VLRX 16
H
D
D3
90
13,5 n4 fori
190
300
165
126
48
28
103
20
215
245
Net Weight
kg
Dimensions mm
Model
A
VLRX 16 - 30/2 F
VLRX 16 - 30 F
VLRX 16 - 40 F
VLRX 16 - 50 F
VLRX 16 - 60 F
VLRX 16 - 70 F
VLRX 16 - 80 F
VLRX 16 - 100 F
VLRX 16 - 120 F
VLRX 16 - 140 F
VLRX 16 - 160 F
460
464
509
575
620
665
710
830
920
1010
1100
62
265
315
335
385
385
385
385
495
495
495
495
725
779
844
960
1005
1050
1095
1325
1425
1505
1595
D3
185
200
200
260
260
260
260
260
260
310
310
130
140
140
185
185
185
185
185
185
230
230
140
250
250
300
300
300
300
350
350
350
350
44
48
51
74
76
82
84
128
132
173
177
ACCESSORIES FOR
VLR
CIRCULAR FLANGES PN 16
CODE
MATERIAL
DESCRIPTION
D3086KKK
Hole No.
140
100
18
11/4
150
110
18
DN40
150
110
18
1 /2
165
125
18
DN50
165
125
18
185
145
18
DN65
220
180
18
DN100
UNI
2254
UNI
2282
UNI
2254
UNI
2282
UNI
2254
UNI
2282
UNI
2282
Stainless
steel
AISI 316
140
99,2
20
11/4 DN32
N/A
MATERIAL
B7097KKK
ZB901890
B
STEEL
B7050KKK
B7075KKK
ZB901920
ZA008460
SPEC
B7098KKK
To be
Threaded welded
PRICE
OVAL FLANGES
CODE
DESCRIPTION
Threaded
PRICE
F
ZC001290
ZC001280
ZA008560
CAST
IRON
95
68
65
11
CAST
IRON
95
68
65
11
11/4
CAST
IRON
128
75
100
14
11/2
95
68
65
11
11/4
Stainless
steel
stamped
AISI 316
SELECTION TABLE
DN 50
DN 65
DN 100
DN 32
PN 16
PN 16
PN 16
PN 16
PN 25
PN 16
PN 16
PN 16
VLR 4 FLANGE A
VLR 4 FLANGE F
VLR 8 FLANGE A
VLR 8 FLANGE F
VLR 16 FLANGE F
B7050KKK
B7051KKK
ZB901890
B7075KKK
ZB901920
ZA008460
11/2
11/4
AISI 316
"
"
"
"
11/4
CAST IRON
"
VLR 2B FLANGE A
VLR 2B FLANGE F
ZA008560
21/2
ZC001280
ZC001290
DN 40
ZC001270
11/2
B7098KKK
TIPO
CODE
Notes
OVAL FLANGES
11/4
B7097KKK
D3086KKK
ACCESSORY
63
"
"
"
"
CIRCULATION PUMPS
50 Hz
CIRCULATION PUMPS
SR3 CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both individual and communal
heating systems.
Design Features
-
Motor
-
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Liquid temperature: from +10 C to +110 C
- Maximum operating pressure: 10 bar
- Pressure necessary at the suction point to avoid cavitation:
1,5 m (at a water temperature of 90 C)
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Civil and industrial pressurised or open tank heating
systems
1 x 230
1"
Motor
Power
W
110
0,48 1800
74
0,32 1200
44
0,19
130
0,30 1950
55
0,24 1550
40
0,18 1150
104
0,45 1850
78
0,35 1400
180
56
0,26 950
130
110
0,48 1800
83
0,37 1400
180
1 x 230
1"
1 x 230
1"
Motor
Power
W
71
2,0
130
130
130
180
2,5
2,8
60
65
10
20
30
40
50
60
70
m /h 0,6
1,2
1,8
2,4
3,0
3,6
4,2
3,7
3,1
1,9
3,0
2,2
1,0
2,2
1,2
1,4 0,5
0,2
5,4
4,0
2,4
4,5
3,0
1,2
3,5
1,8
0,2
2,6
1,0
1,6
5,5
4,5
2,8
4,9
3,5
1,6
3,8
2,2
0,5
3,2
1,3
2,4 1,5
0,4
L/1'
N
Amp. (min
-1
)
2
1
130
700
F.
SPEED
SPEED
3
0,27 1050
PRICE
Q
3
Altezza
manometrica
in m.c.a.
N
Amp. (min
-1
)
(mm)
MODEL
CODE
2,8
VOLTAGE.
(V)
F.
CENTRE
DISTANCE
MODEL
Connections
CODE
VOLTAGE.
(V)
0,8
0,5
SR3
H (m)
P (kPa)
H (m)
P (kPa)
60
70
SR3 15/25-40
6
60
50
40
30
SR3 15/25-50
5
50
40
2
1
0
2
0,5
20
H (m)
2
0,5
(l/sec.)
10
0
5 (m3/h)
10
20
30
0
5 (m3/h)
(l/sec.)
P (kPa)
70
SR3 15/25-60
6
60
50
40
30
20
10
0
0
MODEL
2
0,5
0
5 (m3/h)
(l/sec.)
PACKING
VOLUME
CONNECT.
(dm3)
130
65
105,4
135
46,6
76,7
2,75
1 1/2
130
65
105,4
135
46,6
76,7
2,75
1 1/2
180
90
105,4
135
46,6
76,7
3,55
130
65
105,4
135
46,6
76,7
2,75
1 1/2
130
65
105,4
135
46,6
76,7
2,75
1 1/2
180
90
105,4
135
46,6
76,7
3,55
130
65
105,4
135
46,6
76,7
2,75
1 1/2
130
65
105,4
135
46,6
76,7
2,75
1 1/2
180
90
105,4
135
46,6
76,7
3,55
66
WEIGHT (kg)
net
gross
2,7
2,8
2,7
2,8
2,8
2,9
CIRCULATION PUMPS
R2S 25 CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both individual and communal
heating systems.
Design Features
-
Motor
-
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Liquid temperature: from +10 C to +110 C
- Maximum operating pressure: 10 bar
- Pressure necessary at the suction point to avoid cavitation:
2 m (at a water temperature of 90 C)
- The pump must be installed with the driving shaft in a
horizontal position
3,0
Motor
Power
W
180
F.
SPEED
(mm)
CENTRE
DISTANCE
MODEL
Connections
CODE
VOLTAGE.
(V)
Applications
- Civil and industrial pressurised or open tank heating
systems
3
2
1
140
110
86
n
Amp.
(rpm )
0,70
0,59
0,43
67
2400
2000
1400
l/1'
20
30
40
50
60
80
m3/h
1,2
1,8
2,4
3,0
3,6
4,8
5,8
3,6
1,7
5,5
2,9
1
4,9
2,1
4,2
1,5
3,4
0,8
PRICE
Altezza
manom.
in m.c.a.
R2S 25
H (m)
BA010101 / 03.09.01
P (kPa)
70
R2S 25-70
6
60
50
40
30
20
10
0
0
0
MODEL
R2S 25 - 70
(l/sec.)
0,5
PACKING
VOLUME
CONNECT.
1"1/2
0
5 (m3/h)
WEIGHT (kg)
(dm3)
net
gross
180
90
100
135
46
75
4,5
2,6
2,8
68
OPTIONAL
ACCESSORIES
PIPE FITTING
KIT
CIRCULATION PUMPS
R2S CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both individual and communal
heating systems.
Design Features
- Pump casing in GG20 cast iron
- Glass-fibre reinforced Noryl impeller
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Connections: threaded 40 series
flanged 42 series
- Versions: single
R2S
Motor
- Wet rotor with internal separator sleeve
- Asynchronous single phase
- 3 speed operation
- Provided with built in capacitor
- Class F insulation
- Level protection IP 42
- Power supply voltage: single phase 1 x 230 V - 50 Hz
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Liquid temperature: from +10 C to +110 C
- Maximum operating pressure: 10 bar
- Pressure necessary at the suction point to avoid cavitation:
2 m (at a water temperature of 90 C)
- The pump must be installed with the driving shaft in a
horizontal position
R2S...F
20
30
40
60
80
100
R2S 32 - 60
1 x 230
2"
180
5,0
3
2
1
143
121
110
0,8
0,7
0,6
2600
2300
1500
4,7
4,5
4,2
4,4
4,0
3,4
4,2
3,6
3,0
2,9
2,3
1,6
1,8
N8010000
R2S 32 - 90
1 x 230
2"
180
5,0
3
2
1
1,1
0,9
0,8
2600
2100
1400
6,6
4,9
2,0
4,8
2,6
0,4
2,6
0,2
R2S 40 - 60
1 x 230
2"
180
5,0
0,9
0,8
0,7
2700
2400
1550
7,8
6,8
4,7
4,9
4,7
4,0
7,3
6,0
3,2
N8010002
231
198
181
165
159
143
0,2
N8010001
4,7
4,4
3,6
4,4
4,1
3,2
3,9
3,4
2,5
3,3
2,8
1,8
2,4
2,1
1,2
N8010003
R2S 40 - 90 1 x 230
2"
180
7,0
7,8
3,9
2,3
7,5
3,0
1,7
6,5
1,7
1,0
5,6
1,2
0,8
4,7
0,9
0,4
R2S 42 - 60 F 1 x 230
DN 40
250
PN 6
5,0
N8010005
R2S 42 - 90 F 1 x 230
DN 40
250
PN 6
7,0
2600
1900
1300
2600
2300
1600
2250
1800
1600
8,3
5,0
3,4
N8010004
1,2
1,1
0,9
0,9
0,8
0,7
1,2
1,1
0,9
4,9
4,7
4,0
7,9
6,7
3,8
4,6
4,3
3,6
7,5
5,7
2,9
4,4
4,0
3,2
7,1
4,7
2,0
3,8
3,3
2,2
6,4
2,8
1,2
2,9
2,4
1,3
5,5
1,4
0,7
2,0
1,5
0,2
4,4
0,8
0,4
F.
3
2
1
3
2
1
3
2
1
3
2
1
275
253
187
165
159
143
275
253
187
69
n
Q
(rpm)
150
PRICE
m /h
MODEL
(mm)
Amp.
CODE
Motor
Power
W
l/1'
SPEED
CENTRE
DISTANCE
Connections
VOLTAGE.
(V)
Applications
- Civil and industrial pressurised or open tank heating
systems
1,2
1,8
2,4
3,6
4,8
6,0
9,0
2,4
1,4
R2S
H (m)
P (kPa)
P01024244 / 10.07.01
H (m)
70
P01024547 / 11.07.01
10
9
R2S 32-60
R2S 32-90
P (kPa)
100
90
60
80
50
70
40
60
5
3
30
2
1
10
0
1
0,5
H (m)
1,5
20
10
6 (m3/h)
(l/sec.)
50
40
1,5
(l/sec.)
P01019193 / 08.05.01
P (kPa)
R2S 40-90
80
70
60
50
4
20
40
30
10
20
10
1
0
0
0
4
1
0,5
6
1,5
H (m)
8
2
50
40
0,5
4
1
6
1,5
2,5
0
10 (m3/h)
(l/sec.)
P (kPa)
90
80
70
60
50
40
30
20
10
0
0
0
(l/sec.)
2,5
0,5
4
1
6
1,5
8
2
9
2,5
0
10 (m3/h)
(l/sec.)
R2S 40......
CONNECT.
1,5
P010273 / 19.07.01
0
10 (m3/h)
R2S 42-90F
R2S 42....F
MODEL
0,5
20
10
30
H (m)
60
P (kPa)
R2S 42-60F
(l/sec.)
2,5
P19701.3V / 30.07.01
10 (m3/h)
100
90
6
30
0
6 (m3/h)
0,5
H (m)
R2S 40-60
10
60
30
P (kPa)
P010241 / 10.07.01
40
20
50
PACKING
VOLUME
WEIGHT (kg)
net
gross
4,8
5,0
4,8
5,0
100
5,3
5,5
120
100
5,3
5,5
190
120
100
11
7,5
7,7
190
120
100
11
7,5
7,7
R2S 32 - 60
A
180
B
90
C
125
D
165
E
120
F
100
R2S 32 - 90
180
90
125
165
120
100
R2S 40 - 60
180
90
135
175
120
R2S 40 - 90
180
90
135
175
R2S 42 - 60 F
DN 40
250
125
135
R2S 42 - 90 F
DN 40
250
125
135
70
(dm 3)
ACCESSORIES
ON REQUEST
page 120
CIRCULATION PUMPS
R2SD CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both individual and communal
heating systems.
Design Features
- Pump casing in GG20 cast iron
- Glass-fibre reinforced Noryl impeller
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Connections: threaded
flanged (R2SD 40-50 F)
- Versions: twin
Motor
- Wet rotor with internal separator sleeve
- Asynchronous single phase
- 3 speed operation
- Provided with built in capacitor
- Class F insulation
- Level protection IP 42
- Power supply voltage: single phase 1 x 230 V - 50 Hz
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Liquid temperature: from +10 C to +110 C
- Maximum operating pressure: 10 bar
- Pressure necessary at the suction point to avoid cavitation:
2 m (at a water temperature of 90 C)
- The pump must be installed with the driving shaft in a
horizontal position
20
30
40
60
80
100
150
m3/h
1,2
1,8
2,4
3,6
4,8
6,0
9,0
R2SD 32 - 60 1 x 230
2"
180
3
2
1
143
121
110
0,8
0,7
0,6
2600
2300
1450
5,2
4,8
4,5
4,8
4,5
4,0
4,4
4,0
3,5
3,0
2,6
2,0
0,9
0,6
2"
180
3
2
1
231
198
181
1,1
0,9
0,8
2600
2000
1400
8,0
7,0
4,8
7,5
6,1
3,4
6,9
5,0
2,2
5,4
2,8
0,8
3,2
0,9
1,0
DN40
N8010008 R2SD 42 - 60F 1 x 230 PN6 255
PN10
3
2
1
165
159
143
0,9
0,8
0,7
2400
1800
1150
5,1
4,8
4,1
4,9
4,5
3,6
4,6
4,2
3,1
4,0
3,4
2,1
3,2
2,4
1,3
2,1
1,4
0,6
DN40
N8010009 R2SD 42 - 90F 1 x 230 PN6 255
PN10
3
2
1
275
253
187
1,2
1,1
0,9
2400
1600
1100
7,7
6,3
3,6
7,4
5,2
2,7
7,1
4,1
2,0
6,4
2,3
1,1
5,5
1,2
0,7
4,4
0,7
F.
71
n
Q
(rpm)
PRICE
Discharge Head
in meters
N8010006
MODEL
(mm)
Amp.
CODE
Motor
Power
W
l/1'
SPEED
CENTRE
DISTANCE
Connections
VOLTAGE.
(V)
Applications
- Civil and industrial pressurised or open tank heating
systems
1,2
R2SD
H (m)
H (m)
P (kPa)
P230001b / 07.09.01
P22601b / 07.09.01
60
R2SD 32-60
R2SD 32-90
80
70
40
30
10
1
0
4
1
0,5
H (m)
P22302b / 31.08.01
30
20
10
0
(l/sec.)
P (kPa)
H (m)
60
0
6 (m3/h)
0,5
1,5
P22301e / 28.08.01
R2SD 42-60F
R2SD 42-90F
50
40
0
5 (m3/h)
50
20
60
5
3
40
4
3
20
0
0
0,5
6
1,5
20
10
0
0
(l/sec.)
30
0
8 (m3/h)
1,5
8
2
0
9 (m3/h)
2,5 (l/sec.)
R2SD 42 - 60 F
R2SD 42 - 90 F
CONNECT.
3
1
0,5
R2SD 32-60
R2SD 32-90
MODEL
80
40
2
10
90
50
30
P (kPa)
60
5
3
(l/sec.)
70
7
4
90
8
50
P (kPa)
R2SD 32 - 60
180
105
135
175
235
100
14,2
9,9
10,1
R2SD 32 - 90
180
105
135
175
235
100
14,2
9,9
10,1
R2SD 42 - 60 F DN 40
DN- 40N 10
250
145
135
195
245
100
21,5
15,7
15,9
R2SD 42 - 90 F DN 40
DN- 40
PN 10
250
145
135
195
245
100
21,5
15,7
15,9
72
ACCESSORIES
ON REQUEST
page 120
CIRCULATION PUMPS
R2X - R2B CIRCULATION PUMPS
FOR DOMESTIC WATER
Circulation pumps of the wet rotor type are suitable for the
circulation of hot sanitary water in heating systems.
Materials
- Pump casing
- Impeller
- Motor liner
- Seal ring
- Shaft
- Motor casing
- Pump bearing
- Fifth wheel
R2X Series
R2B Series
Motor
- Wet rotor with liner
- Asynchronous single phase
- One speed operation
- Provided with built in capacitor
- Class F insulation
- Level protection IP 42
- Power supply voltage: single phase 1 x 230 V - 50 Hz
- Direction of rotation (motor end view):
R2X series - anticlockwise
R2B series - anticlockwise
Restrictions
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Linestone-free water (if water exceeds 35 F a softener
device must be installed)
- Suggested water temperature max 60 C
- The pump must be installed with the driving shaft in a
horizontal position (see side picture)
10
20
30
40
50
60
80
m3/h
0,6
1,2
1,8
2,4
3,0
3,6
4,8
B1641600
150
3,0
75
0,36
2200
1,7
1,3
0,7
B1643600
1/4
R2X 20 - 30 1 x 230 1"
150
3,0
87
0,42
2000
2,6
2,0
1,3
0,3
180
5,0
143
0,77
2600
5,3
4,9
4,6
4,1
3,5
2,7
0,5
180
5,0
231
1,1
2600
8,2
7,6
7,1
6,6
6,0
5,2
3,0
F.
n
(rpm) Q
PRICE
1"1/2
N8010014 R2B 30 - 60
1 x 230
N8010010 R2B 32 - 60
2"
N8010015 R2B 30 - 90
1"1/2
1 x 230
Discharge Head
in meters
MODEL
(mm)
Amp.
CODE
Motor
Power
W
l/1'
SPEED
CENTRE
DISTANCE
Connections
VOLTAGE
(V)
Applications
- Sanitary hot water circulation systems, heating and
conditioning systems
N8010011 R2B 32 - 90
2"
2"
180
5,0
165
0,88
2700
5,3
5,0
4,8
4,5
4,2
3,8
3,2
2"
180
7,0
275
1,21
2600
7,6
7,2
6,8
6,4
6,1
5,8
5,1
73
R2X - R2B
H (m)
H (m)
P (kPa)
P31001 / 08.11.01
P31101a / 07.11.01
10
70
R2B 30 / 32-60
R2B 30 / 32-90
P (kPa)
100
90
60
50
40
30
20
30
20
10
2
1
10
0
0
0,5
H (m)
P (kPa)
40
30
2
1
10
0
0
4
1
0,5
6
1,5
8
2
50
40
R2X 20 - 18
R2X 20 - 30
R2B 30 - 60
R2B 32 - 60
R2B 30 - 90
R2B 32 - 90
R2B 40 - 60
R2B 40 - 90
0,5
0
8 (m3/h)
1,5
(l/sec.)
P (kPa)
P010265 / 17.07.01
90
80
70
60
50
40
30
20
10
4
1
0,5
R2X
MODEL
R2B 40-90
(l/sec.)
2,5
10 (m3/h)
20
5
4
H (m)
50
60
R2B 40-60
60
70
(l/sec.)
1,5
P010262 / 17.07.01
80
0
6 (m3/h)
6
1,5
7
2
9
2,5
0
10 (m3/h)
(l/sec.)
R2B
CONNECT.
1/4
1"
150
90
119
154
120
80
4,5
2,0
2,2
1"1/2
2
1"1/2
2
2
2
180
180
180
180
180
180
90
90
90
90
90
90
125
125
125
125
135
135
165
165
165
165
175
175
120
120
120
120
120
120
100
100
100
100
100
100
7
7
7
7
7
7
5,1
5,1
5,1
5,1
5,6
5,6
5,3
5,3
5,3
5,3
5,8
5,8
74
ACCESSORIES
ON REQUEST
(page 128)
CIRCULATION PUMPS
R2C - R4C CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 40 - PN 6/10
- Versions: single
Motor
- Asynchronous wet rotor with internal separator sleeve, 2
pole (R2C) or 4 pole (R4C)
- Two speed operation
- Provided with built in capacitor (single phase models)
- Class F insulation
- Level of protection IP 42
- Power supply voltage: single or three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems
MODEL
B3420374
B3420352
VOLTAGE
SPEED
(V)
1 x 230
R4C 40 - 30
3 x 230
B3420350
3 x 400
B3420624
11 x 2300
B3420602
R2C 40 - 60
3 x 230
B3420600
3 x 400
B3421224
1 x 230
B3421202
B3421200
R2C 40 - 120
3 x 230
3 x 400
Motor
n
Power
Amp. (rpm)
W
max min.
2
1
2
1
250
180
200
108
210
110
150
68
1,14
1,05
1,20
0,48
1450
1320
1410
1190
2
1
200
108
150
68
0,70
0,28
1410
1190
2
1
2
1
337
290
305
202
250
170
210
132
1,54
1,40
1,34
0,64
2760
2470
2810
2520
2
1
305
202
210
132
0,77
0,37
2810
2520
2
1
2
1
540
450
550
370
390
280
335
245
2,46
2,20
1,85
1,10
2710
2150
2710
2110
2
1
550
370
335
245
1,07
0,63
2710
2110
75
l/1'
50
100
150
200 250
m3/h
12
15
3,3
2,8
3,1
2,6
2,6
2,0
2,0
1,2
1,2
0,5
0,3
6,5
5,5
6,2
4,8
5,4
3,7
4,1
2,2
2,7
0,8
1,0
11,8 11,2
9,1 7,3
9,9
5,7
8,3
3,8
6,8
2,3
4,7
0,8
300
F. Q
PRICE
18
12
12
-
Discharge Head
in meters
CODE
20
-
2,2
R2C-R4C 40
B2
B1
B5
H1
D6
D3
D1
D2
D4
H2
H3
G 1/4"
B3
B4
L1
D5
D7
MODEL
D1
D2
D3
D4
D5 nD5 D6 D7 nD7 H1
H2
H3
WEIGHT (kg)
L1
B1
B2
B3
B4
B5
net
gross
PACKING
VOLUME
(dm3)
R4C 40 -
30
42
80 100 150
14
110
19
95
75
90
96 M12
14
16
0,030
R2C 40 -
60
42
80 100 150
14
110
19
67
95
75
90
96 M12
14
16
0,030
R2C 40 - 120
42
80 100 150
14
110
19
95
75
90
96 M12
15
17
0,030
76
75
CIRCULATION PUMPS
R2C - R4C CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 50 - PN 6/10
- Versions: single
Motor
- Asynchronous wet rotor with internal separator sleeve, 2
pole (R2C) or 4 pole (R4C)
- Two speed operation
- Provided with built in capacitor (single phase models)
- Class F insulation
- Level of protection IP 42
- Power supply voltage: single or three phase (except for
mod. R2C 50-180)
- Direction of rotation: anticlockwise (motor end view):
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems
MODEL
B3520374
B3520352
1 x 230
R4C 50 - 30
3 x 230
B3520350
3 x 400
B3540674
1 x 230
B3540652
R4C 50 - 60
3 x 230
B3540650
3 x 400
B3520624
1 x 230
B3520602
R2C 50 - 60
3 x 230
B3520600
3 x 400
B3541224
1 x 230
B3541202
R2C 50 - 120
B3541200
3 x 400
B3541802
B3541800
3 x 230
3 x 230
R2C 50 - 180
3 x 400
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Motor
n
Power
Amp. (rpm)
W
max min.
275
225
230
132
230
132
450
420
425
290
425
290
390
350
390
243
390
243
1020
950
885
650
885
650
1330
940
1330
940
235
130
160
90
160
90
290
195
220
140
220
140
250
190
240
145
240
145
620
450
480
370
480
370
730
530
730
530
1,30
1,27
1,28
0,58
0,74
0,33
2,10
2,25
1,91
1,04
1,10
0,60
1,80
2,25
1,65
0,75
0,95
0,43
4,60
4,50
3,02
2,04
1,75
1,18
4,42
2,85
2,55
1,65
1380
1150
1390
1170
1390
1170
1380
1120
1390
1170
1390
1170
2700
2230
2700
2280
2700
2280
2800
2500
2700
2280
2700
2050
2700
2280
2760
2260
77
F.
l/1'
50
100
200
300 400
500
m3/h
12
18
3,0
2,5
2,8
2,2
2,6
1,9
2,0
1,0
1,0
0,2
5,6
5,0
5,4
4,5
5,2
3,9
4,2
2,5
2,9
1,0
6,9
5,2
6,7
4,8
6,3
4,1
4,7
2,4
2,2
0,4
8,4
6,2
7,2
4,0
4,5
2,0
1,4
9,0
4,0
4,3
0,2
PRICE
24
30
12
20
12
-
Discharge Head
in meters
CODE
VOLTAGE
SPEED
(V)
1,0
35
-
R2C-R4C 50
B2
B1
B5
H1
D6
D3
D1
D2
D4
H2
H3
G 1/4"
B3
B4
L1
D5
D7
MODEL
D1
D2
D3
D4 D5 nD5 D6 D7 nD7 H1
H2
H3
WEIGHT (kg)
L1
B1
B2
B3
B4
B5
75
95
75
net
gross
PACKING
VOLUME
(dm3)
R4C 50 -
30
50
90
110 165
14
125
19
75
102
96 M12
17
19
0,030
R4C 50 -
60
50
90
110 165
14
125
19
75
96 M12
23
26
0,054
R2C 50 -
60
50
90
110 165
14
125
19
75
102
96 M12
17
19
0,030
R2C 50 - 120
50
90
110 165
14
125
19
75
96 M12
24
26
0,054
R2C 50 - 180
50
90
110 165
14
125
19
75
96 M12
25
28
0,054
78
75
95
75
CIRCULATION PUMPS
R2C - R4C CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 65 - PN 6/10
- Versions: single
Motor
- Asynchronous wet rotor with internal separator sleeve, 2
pole (R2C) or 4 pole (R4C)
- Two speed operation
- Class F insulation
- Level of protection IP 42
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems
MODEL
Motor
n
Power
Amp. (rpm)
W
max min.
3 x 230
2
1
305 210
185 120
1,52
0,70
1330
1010
B3620350
3 x 400
2
1
305 210
185 120
0,87
0,40
1330
1010
B3640652
3 x 230
2,55
1,30
1,47
0,55
1,70
1,02
0,98
0,59
4,42
2,85
2,55
1,65
6,65
4,50
3,85
2,60
1400
1190
1400
1190
2780
2270
2780
2270
2760
2260
2760
2260
2810
2420
2810
2420
B3620352
R4C 65 - 30
R4C 65 - 60
3 x 400
B3640650
3 x 230
B3620602
R2C 65 - 60
3 x 400
B3620600
3 x 230
B3641202
R2C 65 - 120
3 x 400
B3641200
3 x 230
B3641802
R2C 65 - 180
B3641800
3 x 400
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
540
370
540
370
478
328
478
328
1330
940
1330
940
1970
1510
1970
1510
280
175
280
175
302
208
302
208
730
530
730
530
950
720
950
720
79
l/1'
100
200
300
400
600
800
m3/h
12
18
24
36
48
2,9
2,4
2,8
2,1
2,4
1,6
1,9
1,0
1,3
0,5
0,1
5,5
5,0
5,4
4,2
4,8
3,4
4,2
2,5
3,2
1,4
1,0
6,3
5,1
6,0
4,1
5,3
3,2
4,2
2,1
2,6
0,9
8,6
4,5
5,7
2,7
9,4
6,3
2,5
0,4
PRICE
Discharge Head
in meters
CODE
VOLTAGE
SPEED
(V)
1,9
R2C-R4C 65
B2
B1
B5
H1
D6
D3
D1
D2
D4
H2
H3
G 1/4"
B3
B4
L1
D5
D7
MODEL
D1
D2
D3
D4 D5 nD5 D6 D7 nD7 H1
H2
H3
L1
WEIGHT (kg)
B1
B2
B3
B4
B5
net
gross
PACKING
VOLUME
(dm3)
R4C 65 -
30
65
14
145
19
82
75
95
75
124
96
M12
23
26
0,054
R4C 65 -
60
65
14
145
19
82
75
95
75
124
96
M12
29
32
0,054
R2C 65 -
60
65
14
145
19
82
96
M12
23
25
0,054
R2C 65 - 120
65
14
145
19
82
96
M12
30
33
0,054
R2C 65 - 180
65
14
145
19
82
96
M12
33
36
0,054
80
CIRCULATION PUMPS
R2C - R4C CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for
the circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 80
- PN 10 version are available on request
- Versions: single
Motor
- Asynchronous wet rotor with internal separator sleeve, 2
pole (R2C) or 4 pole (R4C)
- Two speed operation
- Class F insulation
- Level of protection IP 42
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems
MODEL
VOLTAGE
SPEED
(V)
Motor
Power
Amp.
W
max min.
n
(rpm)
3 x 230
2
1
390 270
273 185
1,82
1,00
1405
1200
B3840350
3 x 400
2
1
390 270
273 185
1,05
0,58
1405
1200
B3840652
3 x 230
2
1
975 470
710 290
4,75
2,50
1400
1200
B3840650
3 x 400
2
1
975
710
470
290
2,75
1,45
1400
1200
B3841202
3 x 230
2
1
1970
1510
950
720
6,65
4,50
2810
2420
B3841200
3 x 400
2
1
1970
1510
730 3,85
530 2,60
2810
2420
B3841802
3 x 230
2
1
2520 2320
1780 1040
7,60
5,40
2800
2450
3 x 400
2
1
2520 2320
1780 1040
4,40
3,10
2800
2450
B3840352
R4C 80 - 30
R4C 80 - 60
R2C 80 - 120
R2C 80 - 180
B3841800
81
l/1'
100
250
500
m3/h
15
30
45
3,7
3,1
3,6
2,8
3,2
2,2
1,9
0,7
0,2
6,0
5,4
5,9
5,2
5,7
4,8
4,7
3,2
2,9
0,9
0,8
9,8
6,9
7,8
4,7
5,0
2,2
4,6
Discharge Head
in meters
CODE
PRICE
60
75
1,3
R2C-R4C 80
B1
B2
B5
D3
H1
B3
MODEL
B4
D1
D2
D4
H2
H3
G 1/4"
L1
D5
PN
bar
D1
D2
D3
D4
D5
nD5
H1
H2
H3
L1
B1
B2
B3
B4
B5
R4C 80 -
30
80
128
150
190
18
97
266
363
360
101
115
101
130
96
M12
32
35
0,054
R4C 80 -
60
80
128
150
190
18
97
286
383
360
101
115
101
130
96
M12
36
39
0,054
R2C 80 - 120
80
128
150
190
18
97
286
383
360
101
115
101
130
96
M12
37
40
0,054
R2C 80 - 180
80
128
150
190
18
97
286
383
360
101
115
101
130
96
M12
37
40
0,054
82
CIRCULATION PUMPS
R4C CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for the
circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 100
- PN 10 versions are available on request
- Versions: single
Motor
- Asynchronous wet rotor with internal separator sleeve, 4 pole
(R4C)
- Two speed operation
- Class F insulation
- Level of protection IP 42
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems
CODE
MODEL
VOLTAGE
SPEED
(V)
3 x 230
B3040352
2
1
Motor
Power
Amp.
W
max min.
669 495
420 340
2,85
1,55
n
(rpm)
l/1'
m /h
2
1
669 495
420 340
1,65
0,90
1370
1130
B3040652
3 x 230
2
1
1235 880
810 595
5,42
2,95
1375
1120
R4C 100 - 60
1235 880
810 595
3,12
1,70
15
30
45
60
75
3,7
3,0
3,4
2,6
3,0
2,0
2,3
1,2
1,4
0,1
0,1
6,0
4,6
5,7
4,2
5,2
3,5
4,7
2,7
3,8
1,6
2,6
0,3
90
1375
1120
83
Discharge Head
in meters
3 x 400
2
1
500
1370
1130
B3040350
3 x 400
250
PRICE
3
R4C 100 - 30
B3040650
1,1
R4C 100
B1
B2
B5
D3
H1
B3
B4
PN
bar
MODEL
D1
D2
D4
H2
H3
G 1/4"
L1
D5
D2
D3
D4
D5
nD5
H1
H2
H3
L1
B1
B2
B3
B4
B5
R4C 100 -
30
100
148
170
210
18
107
305
412
450
101
115
101
167
144 M16
45
48
0,081
R4C 100 -
60
100
148
170
210
18
107
325
432
450
101
115
101
167
144 M16
46
49
0,081
84
CIRCULATION PUMPS
R2CD - R4CD CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for the
circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 40 - PN 6/10
- Versions: twin
Motor
- Asynchronous wet rotor with internal separator sleeve, 2 pole
(R2CD) or 4 pole (R4CD)
- Two speed operation
- Provided with built in capacitor (single phase models)
- Class F insulation
- Level of protection IP 42
- Power supply voltage: single or three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems
MODEL
Motor
Power
Amp.
W
max min.
l/1'
n
(rpm)
F.
2
1
250
180
210
110
1,14
1,05
1450
1320
12
3 x 230
2
1
200
108
150
68
1,20
0,48
1410
1190
B3420250
3 x 400
2
1
200
108
150
68
0,70
0,28
1410
1190
B3420524
1 x 230
2
1
337
290
250
170
1,54
1,40
2760
2470
12
3 x 230
2
1
305
202
210
132
1,34
0,64
2810
2520
B3420500
3 x 400
2
1
305
202
210
132
0,77
0,37
2810
2520
B3421124
1 x 230
2
1
540
450
390
280
2,46
2,20
2710
2150
20
3 x 230
2
1
550
370
335
245
1,85
1,10
2710
2110
3 x 400
2
1
550
370
335
245
1,07
0,63
2710
2110
B3420252
B3420502
B3421102
B3421100
R4CD 40 - 30
R2CD 40 - 60
R2CD 40 - 120
85
50
100
150
200 250
300
PRICE
m3/h
1 x 230
B3420274
Discharge Head
in meters
CODE
VOLTAGE
SPEED
(V)
12
15
3,3
2,8
3,1
2,6
2,6
2,0
2,0
1,2
1,2
0,5
0,3
6,5
5,5
6,2
4,8
5,4
3,7
4,1
2,2
2,7
0,8
1,0
11,8 11,2
9,1 7,5
9,9
6,1
8,3
4,2
6,8
2,2
4,7
0,2
18
2,2
R2CD-R4CD 40
HYDRAULIC PERFORMANCE
WITH ONLY ONE HEAD IN OPERATION
B1
L4
B2
L5
B3
H2
H3
M
G 1/4
B4
D7
H1
B4
B5
D5
G1/8
D1
D2
D3
L2
L3
L1
D6
D4
MODEL
D1 D2 D3
D4 D5 nD5 D6 D7 nD7 H1 H2 H3
L1 L2 L3 L4 L5
B1 B2 B3 B4 B5
R4CD 40 - 30
42
80 100 150 14
4 110 19
68 218 286 250 99 151 97 96 364 184 180 100 200 M12
27
30
0,054
R2CD 40 - 60
42
80 100 150 14
4 110 19
68 218 286 250 99 151 97 96 364 184 180 100 200 M12
27
30
0,054
R2CD 40 - 120
42
80 100 150 14
68 218 286 250 99 151 97 96 364 184 180 100 200 M12
29
32
0,054
110 19
86
CIRCULATION PUMPS
R2CD - R4CD CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for the
circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 50 - PN 6/10
- Versions: twin
Motor
- Asynchronous wet rotor with internal separator sleeve, 2 pole
(R2CD) or 4 pole (R4CD)
- Two speed operation
- Provided with built in capacitor (single phase models)
- Class F insulation
- Level of protection IP 42
- Power supply voltage: single or three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems
MODEL
B3520274
B3520252
VOLTAGE
SPEED
(V)
1 x 230
R4CD 50 - 30
3 x 230
B3520250
3 x 400
B3540574
1 x 230
B3540552
R4CD 50 - 60
B3540550
3 x 400
B3520524
B3520502
3 x 230
1 x 230
R2CD 50 - 60
3 x 230
B3520500
3 x 400
B3541124
1 x 230
B3541102
R2CD 50 - 120
B3541100
3 x 400
B3541702
B3541700
3 x 230
3 x 230
R2CD 50 - 180
3 x 400
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Motor
Power
Amp.
W
max min.
275
225
230
132
230
132
450
420
425
290
425
290
390
350
390
243
390
243
1020
950
885
650
885
650
1330
940
1330
940
235
130
160
90
160
90
290
195
220
140
220
140
250
190
240
145
240
145
620
450
480
370
480
370
730
530
730
530
1,30
1,27
1,28
0,58
0,74
0,33
2,10
2,25
1,91
1,04
1,10
0,60
1,80
2,25
1,65
0,75
0,95
0,43
4,60
4,50
3,02
2,04
1,75
1,18
4,42
2,85
2,55
1,65
n
(rpm)
1380
1150
1390
1170
1390
1170
1380
1120
1390
1170
1390
1170
2700
2230
2700
2280
2700
2280
2800
2500
2700
2280
2700
2050
2700
2280
2760
2260
87
F.
l/1'
50
100
200
300
400
500
m3/h
12
18
24
30
3,0
2,5
2,8
2,2
2,6
1,9
2,0
1,0
1,0
0,2
5,6
5,0
5,4
4,5
5,2
3,9
4,2
2,5
6,9
5,2
6,7
4,8
6,3
4,1
4,7
2,4
PRICE
12
20
12
-
Discharge Head
in meters
CODE
2,9
1,0
1,0
2,2
0,4
35
-
9,4
6,4
7,2
4,2
4,5
2,0
1,5
9,0
3,8
4,3
0,2
R2CD-R4CD 50
HYDRAULIC PERFORMANCE
WITH ONLY ONE HEAD IN OPERATION
WEIGHT (kg)
MODEL
D1 D2 D3 D4 D5 nD5 D6 D7 nD7 H1 H2 H3 L1 L2
L3 L4
L5 B1 B2 B3 B4 B5
net gross
PACKING
VOLUME
(dm3)
R4CD 50 - 30
50 90 110 165 14
4 125 19
76 225 301 280 117 163 120 96 380 193 187 100 200 M12
31
34
0,081
R4CD 50 - 60
50 90 110 165 14
4 125 19
76 260 336 280 120 160 120 120 440 220 220 120 240 M12
43
46
0,081
R2CD 50 - 60
50 90 110 165 14
4 125 19
76 225 301 280 120 160 120 96 440 220 220 100 200 M12
31
34
0,081
R2CD 50 - 120
50 90 110 165 14
4 125 19
76 260 336 280 120 160 120 120 440 220 220 120 240 M12
45
48
0,081
R2CD 50 - 180
50 90 110 165 14
4 125 19
76 261 337 280 120 160 120 120 440 220 220 120 240 M12
48
51
0,081
88
CIRCULATION PUMPS
R2CD - R4CD CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for the
circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 65 - PN 6/10
- Versions: twin
Motor
- Asynchronous wet rotor with internal separator sleeve, 2 pole
(R2CD) or 4 pole (R4CD)
- Two speed operation
- Class F insulation
- Level of protection IP 42
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view):
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems
MODEL
B3620252
VOLTAGE
SPEED
(V)
3 x 230
R4CD 65 - 30
B3620250
3 x 400
B3640552
3 x 230
R4CD 65 - 60
B3640550
3 x 400
B3620502
3 x 230
R2CD 65 - 60
B3620500
3 x 400
B3641102
3 x 230
R2CD 65 - 120
B3641100
3 x 400
B3641702
3 x 230
R2CD 65 - 180
B3641700
3 x 400
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Motor
Power
Amp.
W
max min.
305
185
305
185
540
370
540
370
478
328
478
328
1330
940
1330
940
1970
1510
1970
1510
210
120
210
120
280
175
280
175
302
208
302
208
730
530
730
530
950
720
950
720
1,52
0,70
0,87
0,40
2,55
1,30
1,47
0,55
1,70
1,02
0,98
0,59
4,42
2,85
2,55
1,65
6,65
4,50
3,85
2,60
n
(rpm)
1330
1010
1330
1010
1400
1190
1400
1190
2780
2270
2780
2270
2760
2260
2760
2260
2810
2420
2810
2420
89
l/1'
100
200
300
400
600
800
m3/h
12
18
24
36
48
2,9
2,4
2,8
2,1
2,4
1,6
2,1
1,1
1,5
0,5
0,1
5,5
5,1
5,4
4,1
4,8
3,4
4,2
2,4
3,2
1,6
3,2
6,3
5,1
6,0
4,3
5,3
3,2
4,2
2,1
2,8
0,9
8,7
5,7
6,1
2,7
2,5
0,4
PRICE
Discharge Head
in meters
CODE
1,5
R2CD-R4CD 65
HYDRAULIC PERFORMANCE
WITH ONLY ONE HEAD IN OPERATION
B1
L4
B2
L5
B3
H2
H3
M
G 1/4
B4
D7
H1
B4
B5
D5
G1/8
D1
D2
D3
L2
L3
L1
D6
D4
WEIGHT (kg)
MODEL
D1 D2 D3 D4 D5 nD5 D6 D7 nD7 H1 H2 H3
L1 L2 L3 L4
L5 B1 B2 B3
B4 B5 M
net gross
PACKING
VOLUME
(dm3)
R4CD 65 - 30
145 19
84 226 310 340 136 204 140 96 404 208 196 120 240 M12
40
45
0,096
R4CD 65 - 60
145 19
84 261 345 340 140 200 140 120 455 231 224 100 200 M12
53
58
0,096
R2CD 65 - 60
145 19
84 226 310 340 140 200 140 96 455 231 224 120 240 M12
40
45
0,096
R2CD 65 - 120
145 19
84 261 345 340 140 200 140 120 455 231 224 120 240 M12
54
59
0,096
R2CD 65 - 180
145 19
84 289 373 340 140 200 140 120 455 231 224 120 240 M12
59
64
0,096
90
CIRCULATION PUMPS
R2CD - R4CD CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for the
circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 80
- PN 10 versions are available on request
- Versions: twin
Motor
- Asynchronous wet rotor with internal separator sleeve, 2 pole
(R2CD) or 4 pole (R4CD)
- Two speed operation
- Class F insulation
- Level of protection IP 42
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems
MODEL
VOLTAGE
SPEED
(V)
Motor
n
Power
Amp.
(rpm)
W
max min.
3 x 230
2
1
390
273
B3840250
3 x 400
2
1
390 270
273 185
1,05
0,58
1405
1200
B3840552
3 x 230
2
1
975
710
470
290
4,75
2,50
1400
1200
B3840550
3 x 400
2
1
975 470
710 290
2,75
1,45
1400
1200
B3841102
3 x 230
2
1
1970
1510
950 6,65
720 4,50
2810
2420
B3841100
3 x 400
2
1
1970
1510
730
530
3,85
2,60
2810
2420
B3841702
3 x 230
2
1
2520 2320
1780 1040
7,60
5,40
2800
2450
3 x 400
2
1
2520 2320
1780 1040
4,40
3,10
2800
2450
B3840252
R4CD 80 - 30
R4CD 80 - 60
270 1,82
185 1,00
R2CD 80 - 180
91
100
250
500
m /h
1405
1200
R2CD 80 - 120
B3841700
l/1'
Q
Discharge Head
in meters
CODE
15
30
45
60
3,7
3,1
3,6
2,8
3,2
2,2
1,9
0,7
0,2
6,0
5,4
5,9
5,2
5,7
4,8
4,7
3,2
3,2
0,9
0,8
9,8
6,9
7,8
4,7
5,4
2,2
4,6
75
1,3
R2CD-R4CD 80
HYDRAULIC PERFORMANCE
WITH ONLY ONE HEAD IN OPERATION
B1
L4
B2
L5
B3
H2
H3
G1/8
5
D
MODEL
PN
bar D1 D2
H1
B4
B5
B4
G 1/4
L2
D1
D2
D3
D4
D5 nD5 H1
H2 H3
L1
L3
L1
L2
L3
L4
L5
B1
B2 B3
B4 B5
R4CD 80 -
30
98 269 367 360 145 215 143 120 464 236 228 120 240 M12
50
55
0,096
R4CD 80 -
60
98 289 387 360 145 215 143 120 464 236 228 100 200 M12
60
65
0,096
R2CD 80 - 120
98 289 387 360 145 215 143 120 464 236 228 120 240 M12
61
66
0,096
R2CD 80 - 180
98 289 387 360 145 215 143 120 464 236 228 120 240 M12
61
66
0,096
92
CIRCULATION PUMPS
R4CD CIRCULATION PUMPS
Variable speed pumps of the wet rotor type are suitable for the
circulation of water in both civil and industrial heating,
air-conditioning and refrigeration systems.
Design Features
- Pump casing in GG20 cast iron
- Impeller in AISI 304 stainless steel
- Motor sleeve and guide ring in AISI 304 stainless steel
- Shaft in AISI 431 stainless steel
- Aluminium stator casing
- Graphite pump bearing
- Ceramic thrust bearing
- Thermal protector built into the windings
- Connections: flanged DN 100
- PN 10 versions are available on request
- Versions: twin
Motor
- Asynchronous wet rotor with internal separator sleeve, 4 pole
(R4CD)
- Two speed operation
- Class F insulation
- Level of protection IP 42
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- The pump must be installed with the driving shaft in a
horizontal position
Applications
- Pressurised or open tank heating systems
- Air-conditioning systems
- Domestic hot water distribution systems
CODE
MODEL
B3040252
VOLTAGE
SPEED
(V)
3 x 230
2
1
Motor
n
Amp.
Power
(rpm)
W
max min.
669 495
420 340
2,85
1,55
3 x 400
2
1
669 495
420 340
1,65
0,90
1370
1130
B3040552
3 x 230
2
1
1235 880
810 595
5,42
2,95
1375
1120
R4CD 100 - 60
2
1
1235 880
810 595
3,12
1,70
250
500
m3/h
15
30
45
60
75
3,7
3,0
3,4
2,6
3,0
2,1
2,3
1,2
1,4
0,1
0,1
6,0
4,6
5,7
4,2
5,2
3,5
4,7
2,7
3,8
1,6
2,6
0,3
PRICE
90
1375
1120
93
Discharge Head
in meters
B3040250
3 x 400
1370
1130
R4CD 100 - 30
B3040550
l/1'
Q
1,1
R4CD 100
HYDRAULIC PERFORMANCE
WITH ONLY ONE HEAD IN OPERATION
B1
L4
B2
L5
B3
H2
H3
G1/8
5
D
MODEL
PN
bar D1 D2
H1
B4
B5
B4
G 1/4
L2
D1
D2
D3
D4
D5 nD5 H1
H2 H3
L1
L3
L1
L2
L3
L4
L5
B1
B2 B3
B4 B5
R4CD 100 -
30
108 306 414 450 189 261 187 140 560 286 274 140 240 M16
80
87
0,224
R4CD 100 -
60
108 327 435 450 189 261 187 140 560 286 274 140 240 M16
82
89
0,224
94
CIRCULATION PUMPS
R2T - R4T CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal
and inline flanged connections, is the alternative type of design
and completes the wet rotor circulation pumps
(R2C - R4C series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush
nut in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 40 - PN 6/10
- Versions: single
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2T) or 4 pole (R4T)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all
positions between horizontal and vertical
D5
D7
WEIGHT (kg)
MODEL
gross
net
D2
H2
H3
B3
B4
B5
R4T 40 - 30
42
80 100 150
14
110 19
67
101 75
90
96 M12
20
22
0,039
R2T 40 - 60
42
80 100 150
14
110 19
67
90
96 M12
20
22
0,039
R2T 40 - 120
42
80 100 150
14
110 19
67
90
96 M12
20
22
0,039
B1
l/1'
Ia / I n
Q
(%)
m3/h
CODE
MODEL
Motor
Power
(kW)
B2001011
R4T 40 - 30
0,25
1,10
1,90
1380
4,6
B2001015
R2T 40 - 60
0,37
1,00
1,73
2840
4,1
B2001017
R2T 40 - 120
0,55
1,45
2,50
2810
5,2
Amp.
n
3x400 V 3x230 V (rpm)
L1
95
Discharge Head
in meters
D3
D4 D5 nD5 D6 D7 nD7 H1
D1
B2
PACKING
VOLUME
(dm3)
101 75
25
50
100
150
200
250
1,5
12
15
3,3
3,2
3,1
2,7
2,4
1,7
6,8
6,7
6,5
5,8
4,8
3,4
1,8
9,2
7,4
5,3
PRICE
D4
D1
D2
D3
D6
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops
R2T-R4T 40
96
CIRCULATION PUMPS
R2T - R4T CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal
and inline flanged connections, is the alternative type of design
and completes the wet rotor circulation pumps
(R2C - R4C series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush
nut in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium statar casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 50 - PN 6/10
- Versions: single
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2T) or 4 pole (R4T)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all
positions between horizontal and vertical
D5
D7
WEIGHT (kg)
MODEL
D3
D4 D5 nD5 D6 D7 nD7 H1
D1
D2
R4T 40 - 30
42
80 100 150
14
110 19
67
R2T 40 - 60
42
80 100 150
14
110 19
R2T 40 - 120
42
80 100 150
14
110 19
CODE
MODEL
Motor
Power
(kW)
B2001021
R4T 50 - 30
0,25
1,10
B2001023
R4T 50 - 60
0,37
B2001027
R2T 50 - 120
B2001025
R2T 50 - 180
H2
H3
B4
B5
101 75
90
96 M12 20
22
0,039
67
90
96 M12 20
22
0,039
67
90
96 M12 20
22
0,039
1,90
1380
4,6
1,25
2,15
1390
4,2
0,75
1,90
3,30
2810
4,5
1,10
2,60
4,50
2860
5,2
97
Discharge Head
in meters
l/1'
Ia / I n
Q
(%)
m3/h
B1
B2
101 75
net gross
B3
n
(rpm)
Amp.
3x400 V 3x230 V
L1
PACKING
VOLUME
(dm3)
50
100
200
300
400
500
12
18
24
30
3,1
3,0
2,8
2,5
1,5
5,9
5,7
5,4
4,5
3,3
1,4
9,1
7,0
3,9
1,2
PRICE
D4
D1
D2
D3
D6
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops
R2T-R4T 50
98
CIRCULATION PUMPS
R2T - R4T CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal
and inline flanged connections, is the alternative type of design
and completes the wet rotor circulation pumps
(R2C - R4C series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush
nut in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 65 - PN 6/10
- Versions: single
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2T) or 4 pole (R4T)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all positions
between horizontal and vertical
D5
D7
D1
D2
D3 D4 D5 nD5 D6 D7 nD7 H1 H2
H3
L1
B1
B2
B3
B4
B5
gross
75 124
96 M12
26
29
0,073
75 124
96 M12
29
32
0,073
96 M12
33
36
0,073
96 M12
36
39
0,073
R4T 65 - 30
65
14
145 19
R4T 65 - 60
65
14
145 19
R2T 65 - 120
65
14
145 19
R2T 65 - 180
65
14
145 19
CODE
MODEL
Motor
Power
(kW)
B2001031
R4T 65 - 30
0,25
1,10
1,90
1380
4,6
B2001033
R4T 65 - 60
0,37
1,25
2,15
1390
4,2
B2001037
R2T 65 - 120
1,10
2,50
4,30
2840
5,8
B2001035
R2T 65 - 180
1,50
3,40
5,90
2870
6,0
l/1'
Ia / I n
Q
(%)
m3/h
99
Discharge Head
in meters
Amp.
n
3x400 V 3x230 V (rpm)
net
PACKING
VOLUME
(dm3)
WEIGHT (kg)
MODEL
0
0
70 101
101
100
6
200
12
300
18
400
24
500
30
3,0
2,9
2,7
2,3
1,8
1,2
5,5
5,4
4,9
4,4
3,6
2,7
9,9
9,0
7,8
6,7
700
42
4,2
PRICE
D4
D1
D2
D3
D6
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops
R2T-R4T 65
100
CIRCULATION PUMPS
R2T - R4T CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal
and inline flanged connections, is the alternative type of design
and completes the wet rotor circulation pumps
(R2C - R4C series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush
nut in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 80
- PN 10 versions are available on request
- Versions: single
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2T) or 4 pole (R4T)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all
positions between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops
MODEL
PN
bar
D1
D2
D4
D3
D5 nD5
H1
H2
H3
L1
B1
B2
B3
B4
B5
97
348
445
360
70
101
101
130
96
M12
32
35
0,073
R4T 80 -
30
80
128
150
190
18
R4T 80 -
60
80
128
150
190
18
97
383
480
360
80
115
101
130
96
M12
36
39
0,073
R2T 80 - 120
80
128
150
190
18
97
433
530
360
90
115
101
130
96
M12
41
44
0,073
R2T 80 - 180
80
128
150
190
18
97
433
530
360
90
115
101
130
96
M12
41
44
0,073
CODE
MODEL
Motor
Power
(kW)
B2001041
R4T 80 - 30
0,25
1,10
B2001043
R4T 80 - 60
0,75
B2001047
R2T 80 - 120
B2001045
R2T 80 - 180
l/1'
Ia / I n
Q
(%)
m3/h
0
0
1,90
1380
4,6
2,25
3,90
1405
5,1
2,20
4,80
8,30
2870
4,8
2,20
4,80
8,30
2870
4,8
101
Discharge Head
in meters
n
(rpm)
Amp.
3x400 V 3x230 V
200
12
300
18
400
24
500
30
750 1000
45
60
3,7
3,3
3,0
2,5
2,0
6,0
5,8
5,6
5,3
4,9
3,3
8,4
6,4
5,5
PRICE
R2T-R4T 80
102
CIRCULATION PUMPS
R2T - R4T CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal
and inline flanged connections, is the alternative type of design
and completes the wet rotor circulation pumps
(R2C - R4C series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush
nut in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 100
- PN 10 versions are available on request
- Versions: single
Motor
- Squirrel cage asynchronous three phase with enclosed
stator, externally ventilated, 2 pole (R2T) or 4 pole (R4T)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all
positions between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops
MODEL
PN
bar
D1
D2
D4
D3
D5 nD5
H1
H2
H3
L1
B1
B2
B3
B4
B5
R4T 100 -
30
100
148
170
210
18
107
421
528
450
80
115
101
167
144 M16
49
56
0,249
R4T 100 -
60
100
148
170
210
18
107
457
564
450
90
115
101
167
144 M16
57
64
0,249
100
148
170
210
18
107
507
614
450
100
130
101
167
144 M16
62
69
0,249
CODE
MODEL
Motor
Power
(kW)
B2001051
R4T 100 - 30
0,55
1,70
2,90
1390
4,5
B2001053
R4T 100 - 60
1,10
3,00
5,20
1395
4,0
B2001057
3,00
6,30
10,90
2870
4,2
l/1'
Ia / I n
Q
(%)
m3/h
103
Discharge Head
in meters
Amp.
n
3x400 V 3x230 V (rpm)
0
0
250
15
500
30
4,0
3,7
3,2
2,4
1,3
6,0
5,9
5,7
5,3
4,6
3,4
9,4
7,4
4,5
PRICE
R2T-R4T 100
104
CIRCULATION PUMPS
R2TD - R4TD CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the circulation
of hot and cold water in heating and air-conditioning systems. The
type of design: external motor, mechanical seal and inline flanged
connections, is the alternative type of design and completes the
wet rotor circulation pumps (R2CD - R4CD series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush nut
in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 40 - PN 6/10
- Versions: twin
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2TD) or 4 pole (R4TD)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of suspended
solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all positions
between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops
D7
D5
D1
D2
D3
D6
D4
WEIGHT (kg)
MODEL
net gross
D1 D2 D3 D4 D5 nD5 D6 D7 nD7 H1 H2 H3 L1
L2 L3 L4
L5 B1
B2 B3 B4 B5
PACKING
VOLUME
(dm3)
R4TD 40 - 30
42 80 100 150 14
110 19
27
30
0,068
R2TD 40 - 60
42 80 100 150 14
110 19
27
30
0,068
R2TD 40 - 120
42 80 100 150 14
110 19
68 343 411 250 99 151 97 96 184 101 180 100 200 M12
29
32
0,073
CODE
MODEL
Motor
Power
(kW)
B2001010
R4TD 40 - 30
2 x 0,25
1,10
1,90
1380
4,6
B2001016
R2TD 40 - 60
2 x 0,37
1,00
1,73
2840
4,1
B2001018
R2TD 40 - 120
2 x 0,55
1,45
2,50
2810
5,2
l/1'
Ia / I n
Q
(%)
m3/h
105
Discharge Head
in meters
Amp.
n
3x400 V 3x230 V (rpm)
0
0
25
1,5
50
3
100
6
150
9
3,3
3,1
6,8
6,2
200 250
15
12
2,8
2,4
1,8
5,8
4,8
3,6
2,0
8,5
6,2
PRICE
R2TD-R4TD 40
106
CIRCULATION PUMPS
R2TD - R4TD CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal and
inline flanged connections, is the alternative type of design and
completes the wet rotor circulation pumps (R2CD - R4CD series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush nut
in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 50 - PN 6/10
- Versions: twin
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2TD) or 4 pole (R4TD)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all positions
between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops
D7
D5
D1
D2
D3
D6
D4
D1 D2 D3
D4 D5 nD5 D6 D7 nD7 H1 H2 H3
L1
L2
L3 L4
net
gross
PACKING
VOLUME
(dm3)
WEIGHT (kg)
MODEL
L5 B1 B2 B3 B4 B5
R4TD 50 - 30
50
90 110 165 14
4 125 19
76 337 413 280 117 163 120 96 380 193 187 100 200 M12
31
34
0,073
R4TD 50 - 60
50
90 110 165 14
4 125 19
76 337 413 280 120 160 120 120 440 220 220 120 240 M12
43
46
0,073
R2TD 50 - 120
50
90 110 165 14
4 125 19
76 337 413 280 120 160 120 120 440 220 220 120 240 M12
31
34
0,073
R2TD 50 - 180
50
90 110 165 14
4 125 19
76 337 413 280 120 160 120 120 440 220 220 120 240 M12
35
38
0,073
CODE
MODEL
Motor
Power
(kW)
B2001020
R4TD 50 - 30
2 x 0,25
1,10
1,90
1380
4,6
B2001022
R4TD 50 - 60
2 x 0,37
1,25
2,15
1390
4,2
B2001028
R2TD 50 - 120
2 x 0,75
1,90
3,30
2810
4,5
B2001026
R2TD 50 - 180
2 x 1,10
2,60
4,50
2860
5,2
n
(rpm)
l/1'
Ia / I n
Q
(%)
m3/h
107
Discharge Head
in meters
Amp.
3x400 V 3x230 V
0
0
50
3
100
6
200
12
300
18
400
24
3,1
2,8
2,7
1,9
0,8
5,9
5,7
5,4
4,2
3,6
1,4
9,9
7,8
5,2
5,8
500
30
PRICE
R2TD-R4TD 50
108
CIRCULATION PUMPS
R2TD - R4TD CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal and
inline flanged connections, is the alternative type of design and
completes the wet rotor circulation pumps (R2CD - R4CD series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush nut
in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator Casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 65 - PN 6/10
- Versions: twin
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2TD) or 4 pole (R4TD)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 10 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all positions
between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops
D7
D5
D1
D2
D3
D6
D4
D1 D2 D3 D4 D5 nD5 D6 D7 nD7 H1 H2 H3 L1
L2 L3
L4
net
gross
PACKING
VOLUME
(dm3)
WEIGHT (kg)
MODEL
L5 B1 B2 B3 B4 B5
R4TD 65 - 30
4 145 19
84 347 431 340 136 204 120 96 404 208 196 120 240 M12
45
50
0,073
R4TD 65 - 60
4 145 19
84 347 431 340 140 200 140 120 455 231 224 100 200 M12
40
45
0,073
R2TD 65 - 120
4 145 19
84 382 466 340 140 200 140 120 455 231 224 120 240 M12
40
45
0,073
R2TD 65 - 180
4 145 19
84 401 485 340 140 200 140 120 455 231 224 120 240 M12
46
51
0,073
CODE
MODEL
Motor
Power
(kW)
B2001030
R4TD 65 - 30
2 x 0,25
1,10
1,90
1380
4,6
B2001032
R4TD 65 - 60
2 x 0,37
1,25
2,15
1390
4,2
B2001038
R2TD 65 - 120
2 x 1,10
2,50
4,30
2840
5,8
B2001036
R2TD 65 - 180
2 x 1,50
3,40
5,90
2870
6,0
l/1'
Ia / I n
Q
(%)
m3/h
0
0
109
Discharge Head
in meters
Amp.
n
3x400 V 3x230 V (rpm)
100
6
200
12
300
18
400
24
500
30
3,0
2,8
2,4
1,9
1,3
5,3
5,2
4,7
4,0
2,8
1,6
9,3
8,2
7,0
7,2
700
42
PRICE
R2TD-R4TD 65
110
CIRCULATION PUMPS
R2TD - R4TD CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal and
inline flanged connections, is the alternative type of design and
completes the wet rotor circulation pumps (R2CD - R4CD series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush nut
in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 80
- PN 10 versions are available on request
- Versions: twin
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2TD) or 4 pole (R4TD)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all positions
between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops
PN
bar D1 D2
MODEL
D5 nD5 H1
H2 H3
L1
L2
L3
L4
L5
B1 B2
B3 B4 B5
R4TD 80 -
30
98 348 446 360 145 215 140 120 464 236 228 120 240 M12
54
59
0,073
R4TD 80 -
60
80
98 375 481 360 145 215 143 120 464 236 228 120 240 M12 50
55
0,073
R2TD 80 - 120
80
98 433 531 360 145 215 143 120 464 236 228 120 240 M12
60
65
0,224
R2TD 80 - 180
80
98 433 531 360 145 215 143 120 464 236 228 120 240 M12
66
65
0,224
CODE
MODEL
Motor
Power
(kW)
B2001040
R4TD 80 - 30
2 x 0,25
1,10
1,90
1380
4,6
B2001042
R4TD 80 - 60
2 x 0,75
2,25
3,90
1405
5,1
B2001048
R2TD 80 - 120
2 x 2,20
4,80
8,30
2870
4,8
B2001046
R2TD 80 - 180
2 x 2,20
4,80
8,30
2870
4,8
l/1'
Ia / I n
Q
(%)
m3/h
111
Discharge Head
in meters
Amp.
n
3x400 V 3x230 V (rpm)
0
0
200
12
300
18
400
24
500
30
750 1000
45
60
3,7
3,2
2,7
2,2
1,5
6,0
5,7
5,2
4,7
4,3
2,5
9,8
9,2
6,8
6,4
3,5
PRICE
R2TD-R4TD 80
112
CIRCULATION PUMPS
R2TD - R4TD CIRCULATION PUMPS
Mechanically sealed circulation pumps are suitable for the
circulation of hot and cold water in heating and air-conditioning
systems. The type of design: external motor, mechanical seal and
inline flanged connections, is the alternative type of design and
completes the wet rotor circulation pumps (R2CD - R4CD series).
Design Features
- Pump casing, motor bracket in GG20 cast iron
- Impeller, impeller guide ring, tapered bush and tapered bush nut
in AISI 304 stainless steel
- Shaft in AISI 420 stainless steel
- Aluminium stator casing
- Mechanical seal with graphite primary ring,
tungsten carbide secondary ring and EPDM O-ring
- Connections: flanged DN 100
- PN 10 versions are available on request
- Versions: twin
Motor
- Squirrel cage asynchronous three phase with enclosed stator,
externally ventilated, 2 pole (R2TD) or 4 pole (R4TD)
- Class F insulation
- Level of protection IP54
- Design V 18
- Power supply voltage: three phase
- Direction of rotation: anticlockwise (motor end view)
Usage Limitations
- Non-aggressive and non-explosive clean liquids free of
suspended solid particles and fibres
- Hot water or coolants not containing mineral oils
- Liquid temperature: from -20 C to +130 C
- Maximum operating pressure: 6 bar
- Maximum environmental temperature: 40 C
- The pump may be installed with the driving shaft in all positions
between horizontal and vertical
Applications
- Heating and air-conditioning systems
- Water supply systems
- Booster systems
- Agriculture and fruit and vegetable crops
PN
bar D1
MODEL
D5 nD5 H1
H2 H3
L1
L2
L3
L4
L5
B1 B2
B3 B4
B5
R4TD 100 -
30
108 421 529 450 189 261 143 140 560 286 274 140 280 M16
61
68
0,224
R4TD 100 -
60
108 457 565 450 189 261 187 140 560 286 274 140 280 M16
80
87
0,224
108 504 615 450 189 261 187 140 560 286 274 140 280 M16
82
89
0,224
CODE
MODEL
Motor
Power
(kW)
B2001050
R4TD 100 - 30
2 x 0,55
1,70
2,90
1390
4,5
2 x 1,10
3,00
5,20
1395
4,0
B2001058
2 x 3,00
6,30
10,90
2870
4,2
l/1'
Ia / I n
Q
(%)
m3/h
113
Discharge Head
in meters
Amp.
n
3x400 V 3x230 V (rpm)
0
0
250
15
500
30
3,8
3,3
2,8
2,1
6,0
5,6
5,1
4,3
3,4
8,6
PRICE
R2TD-R4TD 100
114
CIRCULATION PUMPS
A2L - A4L - CIRCULATION PUMPS
Applications
- Heating and air-conditioning systems
- Water lifting from lakes , rivers, wells, etc.
- Irrigation systems on ground surface or by sprinkling.
- Water supply and distribution for isolated houses or small villages.
- Pressure systems.
- Industrial services.
- Domestic hot water supply systems.
Construction features
It is a single impeller centrifugal pump coupled by a spindle to a totally
enclosed asynchronous motor. The motor cooling is obtained by means
of external ventilation. The shaft seal is of the mechanical type.
Single construction. Performance data as given on the guidelist and
on the nameplate refer to continuous duty and clear water ( specific
Weight: 1000 Kg / m3 ) with a manometric suction head of 2 meters.
Installation
Since suction and delivery are in-line, pump can be installed in line
with the piping, either horizontally or vertically. Do not install the pump
with motor facing downwards.
On request the pumps can be supplied with flanged counterflanges.
Construction materials
- Pump casing : Cast iron
- Impeller : Cast iron
- Shield, lantern, cover: cast iron
- Shaft: Stainless steel
Pump working limits
- Max working pressure: 10 bar .
- Max liquid temperature: +130 C .
- Min. liquid temperature : -10 C
- Max ambient temperature : +40 C
- Max liquid viscosity : 5 E.
Motor
Asynchronous Threephase motor.
- Protection: IP 54
- Standard voltages:
50 Hz: V. 220 - 400 ( +-10 % )
- Insulation: Class F
Tolerances
- Pump: ISO 2548 class C annex B.
- Motor: according to CEI standards.
A2L
A4L
H
[m]
H
[m]
100-250
50
20
40-200
65-200
40
80-200
100-200
50-200
100-250
15
30
80-200
40-160
50-160
25
20
65-160
80-160
40-125
15
50-125
40-200
10
100-160
65-200
100-200
8
40-160
65-125
80-160
50-200
100-160
65-160
5
50-160
10
8
6
5
2
4
1,2
12
24
60
120
0,6
180
Q [m3/h]
1,2
12
24
60
120
180
Q [m3/h]
115
A2L - A4L 40
CODE
Motor
Power
MODEL
L/1' 50
n -1
Q
(min
)
3x400V 3x230V
m3/h 3
Amp.
(Kw)
75
100 125 150 175 200 225 250 300 350 400
PRICE
4,5
7,5
10,5
12
13,5
9,2
8,9
8,3
7,7
0,37
1,15
4 poli
9,4
6,9
5,8
4,7
9,8
15
18
3,5
4 poli
0,9
2,4
4,2
4 poli
0,75
1,9
3,3
2 poli
9,5
1,0
2,4
4,2
2 poli
1,5
3,6
6,2
2 poli
2,0
4,4
7,7
2 poli
3,0
6,4
11
2 poli
3,0
6,4
11
2 poli
4,0
8,8
15,2
5,5
11,3
6,3
12,8
Discharge Head
in meters
0,75
21
24
20,5
20
19
18
17
16
15
11,5
7,5
24,5
24
23,5
23
22
21
20
16,5
13
28,5
28
23
20
15
33,5
33
32,5
32
31
30
29
26
22,5
38
37,5
37
36
35
34
33
30
26,5
2 poli
47
46,5
46
45
44
43
42
2 poli
55
54,5
54
53,5
53
52
51
48
45
42
2 poli
62
61,5
61
60
59
58
57
54
52,5
49
39,5 37,5
35
E
B
F
D
MODEL
MOTOR
DN : Flanges
DN
n d holes e
WEIGHT (kg)
FLANGES mm.
DNa
DNm
a
A4L 40 - 160 X
71
40 PN10
88
110
150
18
425
100
325
215
103
107
320
170
150
23
A4L 40 - 200 X
80
40 PN10
88
110
150
18
445
100
345
245
127
118
380
200
180
31
A4L 40 - 200 Y
80
40 PN10
88
110
150
18
445
100
345
245
127
118
380
200
180
30
A2L 40 - 125 A
80
40 PN10
88
110
150
18
445
100
345
211
93
118
300
160
140
26
A2L 40 - 125 B
80
40 PN10
88
110
150
18
445
100
345
211
93
118
300
160
140
25
A2L 40 - 125 C
71
40 PN10
88
110
150
18
425
100
325
200
93
107
300
160
140
24
A2L 40 - 160 A
90
40 PN10
88
110
150
18
485
100
385
257
108
149
320
170
150
37
A2L 40 - 160 B
90
40 PN10
88
110
150
18
485
100
385
257
108
149
320
170
150
35
A2L 40 - 160 C
80
40 PN10
88
110
150
18
445
100
345
226
108
118
320
170
150
30
A2L 40 - 200 A
112
40 PN10
88
110
150
18
535
100
435
286
127
159
380
200
180
56
A2L 40 - 200 B
112
40 PN10
88
110
150
18
535
100
435
286
127
159
380
200
180
55
A2L 40 - 200 C
110
40 PN10
88
110
150
18
525
100
425
286
127
159
380
200
180
50
116
A2L - A4L 50
CIRCULATION PUMPS
CODE
MODEL
Motor
Power
(Kw)
L/1' 100 125 150 175 200 225 250 300 350 400 450 500 600
n -1
Q
(min
)
3x400V 3x230V
m3/h 6 7,5 9 10,5 12 13,5 15 18 21 24 27 30 36
Amp.
0,5
1,6
2,8
4 poli
8,8 8,6
1,1
2,6
4,5
4 poli
1,1
2,6
4,5
4 poli
1,5
3,6
6,2
2 poli
2,0
4,4
7,7
2 poli
3,0
8,8
15,2
2 poli
3,0
6,4
11
2 poli
4,0
8,8
15,2
2 poli
5,5
11,3
2 poli
6,3
12,8
2 poli
7,5
17,3
2 poli
8,3 8,0
7,7
4,5
7
8,3
10
Discharge Head
in meters
PRICE
22 20,5 17
23
18
27
30
28 26,5 25
29
46
44
43 41,5 39
51
50
49 47,5 45 42,5 37
51
37
31
49
44
E
B
F
D
MODEL
MOTOR
DN : Flanges
DN
n d holes e
WEIGHT (kg)
FLANGES mm.
DNa
DNm
a
A4L 50 - 160 X
71
50 PN10
102
125
165
18
435
110
325
220
113
107
340
180
160
25
A4L 50 - 200 X
90
50 PN10
102
125
165
18
495
110
385
280
131
149
400
220
180
36
A4L 50 - 200 Y
90
50 PN10
102
125
165
18
495
110
385
280
131
149
400
220
180
36
A2L 50 - 125 A
90
50 PN10
102
125
165
18
495
110
385
252
103
149
320
180
140
32
A2L 50 - 125 B
80
50 PN10
102
125
165
18
455
110
345
221
103
118
320
180
140
28
A2L 50 - 125 C
80
50 PN10
102
125
165
18
455
110
345
221
103
118
320
180
140
27
A2L 50 - 160 A
100
50 PN10
102
125
165
18
535
110
425
272
113
159
340
180
160
42
A2L 50 - 160 B
90
50 PN10
102
125
165
18
495
110
385
262
113
149
340
180
160
32
A2L 50 - 200 A
132
50 PN10
102
125
165
18
650
110
540
315
131
184
400
220
180
64
A2L 50 - 200 B
112
50 PN10
102
125
165
18
545
110
435
290
131
159
400
220
180
57
A2L 50 - 200 C
112
50 PN10
102
125
165
18
545
110
435
290
131
159
400
220
180
56
117
A2L - A4L 65
CIRCULATION PUMPS
CODE
MODEL
L/1' 200 225 250 300 350 400 450 500 600 700 800 900 1000
Amp.
n
Q
-1
3x400V 3x230V (min )
m3/h 12 13,5 15 18 21 24 27 30 36 42 48 54 60
Motor
Power
(Kw)
0,75
3,5
4 poli
8,2
0,9
2,4
4,2
4 poli
9,0
1,1
2,6
4,5
1,5
3,5
6,1
2,0
4,4
7,7
2 poli
3,0
6,4
11
2 poli
4,0
8,8
15,2
2 poli
5,5
11,3
2 poli
7,5
17,3
2 poli
37 36,5 36
35
10
22,5
2 poli
51 50,5 50
48 45,5 42 39,5 37
12,5
27
2 poli
58 57,5 57
55
7,4
7,0
8,4
8,1
4 poli
4 poli
5,0
15
13
Discharge Head
in meters
7,9 7,7
17 16,5 16
21 20,5 20
11
19 17,5 16
14
12
23 21,5 20
18
24
25,5 25,3 25
26 23,5
34 32,5 31
53
PRICE
29
50 46,5 42,5
E
B
MODEL
MOTOR
DN : Flanges
DN
n d holes e
FLANGES mm.
DNa
DNm
WEIGHT (kg)
A4L 65 - 160 X
80
65 PN10
122
145
185
18
485
140
345
240
122
118
400
220
180
33
A4L 65 - 160 Y
80
65 PN10
122
145
185
18
485
140
345
240
122
118
400
220
180
32
A4L 65 - 200 X
90
65 PN10
122
145
185
18
525
140
385
285
136
149
440
240
200
40
A4L 65 - 200 Y
90
65 PN10
122
145
185
18
525
140
385
285
136
149
440
240
200
38
A2L 65 - 125 A
100
65 PN10
122
145
185
18
565
140
425
267
108
159
360
205
155
43
A2L 65 - 125 B
90
65 PN10
122
145
185
18
525
140
385
257
108
149
360
205
155
39
A2L 65 - 125 C
80
65 PN10
122
145
185
18
485
140
345
226
108
118
360
205
155
32
A2L 65 - 160 A
132
65 PN10
122
145
185
18
680
140
540
306
122
184
400
220
180
61
A2L 65 - 160 B
112
65 PN10
122
145
185
18
575
140
435
281
122
159
400
220
180
54
A2L 65 - 200 A
132
65 PN10
122
145
185
18
680
140
540
320
136
184
440
240
200
77
A2L 65 - 200 B
132
65 PN10
122
145
185
18
680
140
540
320
136
184
440
240
200
70
118
A2L - A4L 80
CIRCULATION PUMPS
CODE
MODEL
Motor
Power
(Kw)
L/1' 300 350 400 450 500 600 700 800 900 1000 1100 1200 1250 1500 1750 2000 2250
Amp.
n
-1 Q
3x400V 3x230V (min )
m3/h 18 21 24 27 30 36 42 48 54 60 66 72 75 90 105 120 135
1,1
2,6
4,5
2 poli
8,6 8,5 8,4 8,3 8,2 8,0 7,5 6,8 6,0 5,0
1,5
3,5
6,1
2 poli
2,2
5,1
8,9
2 poli
3,0
6,9
12
2 poli
10
22,5
2 poli
12,5
27
2 poli
15
32
2 poli
15
32
2 poli
18,5
38
2 poli
22
44,5
2 poli
PRICE
Discharge Head
in meters
11
27 23
19
30
24
E
B
F
D
MODEL
MOTOR
DN : Flanges
DN
n d holes e
FLANGES mm.
DNa
DNm
WEIGHT (kg)
A4L 80 - 160 X
90
80 PN10
138
160
200
18
545
140
325
280
131
149
440
240
200
40
A4L 80 - 160 Y
90
80 PN10
138
160
200
18
545
140
325
280
131
149
440
240
200
38
A4L 80 - 200 X
100
80 PN10
138
160
200
18
585
140
345
305
146
159
500
275
225
57
A4L 80 - 200 Y
100
80 PN10
138
160
200
18
585
140
345
305
146
159
500
275
225
51
A2L 80 - 160 A
132
80 PN10
138
160
200
18
700
160
540
315
131
184
440
240
200
85
A2L 80 - 160 B
132
80 PN10
138
160
200
18
700
160
540
315
131
184
440
240
200
79
A2L 80 - 160 C
132
80 PN10
138
160
200
18
700
160
540
315
131
184
440
240
200
72
A2L 80 - 200 B
180
80 PN10
138
160
200
18
860
160
700
375
146
229
500
275
225
142
A2L 80 - 200 C
160
80 PN10
138
160
200
18
860
160
700
375
146
229
500
275
225
124
A2L 80 - 200 D
132
80 PN10
138
160
200
18
700
160
540
330
146
184
500
275
225
91
119
CIRCULATION PUMPS
CODE
Motor
Power
MODEL
(Kw)
Amp.
n
-1 Q
3x400V 3x230V (min )
L/1' 600 700 800 900 1000 1100 1200 1250 1300 1500 1750 2000 2250 2500 2750 3000 3500
PRICE
36
m3/h
42
48
54
60
66
72
75
78
1,5
3,5
6,1
4 poli
2,2
5,1
8,9
4 poli
3,0
6,9
12
4 poli
4,0
9,2
16
4 poli
14,5 14,2 14 13,8 13,5 13,1 12,7 12,4 12,2 11 9,0 6,5
5,5
12
4 poli
7,5
16
4 poli
10
22,5
2 poli
12,5
27
2 poli
15
32
2 poli
29 27,5 26 24,5
18,5
38
2 poli
35
33 30,5 38
22
44,5
2 poli
41
39
37
34
30
58
2 poli
37
71
2 poli
55 54,5 54,3 54 54 53 52
57 56,9 56,8 56,8 56,6 56,5 56
51
55
49 47 45
54 52,5 51
43
48
37
42
37
71
2 poli
65
63
58
55
47
Discharge Head
in meters
7,7 7,5 7,3 7,0 6,7 6,4 6,1 5,7 5,8 5,0
8
16
14
12
19
17
68 67,5 67
21 19,5 18 16,5 15
26 24,5 23 21,5 20 18,5
66
61
E
B
F
D
MODEL
MOTOR
DN : Flanges
DN
n d holes e
FLANGES mm.
DNa
DNm
WEIGHT (kg)
100
100 PN10
158
180
220
18
615
190
425
295
136
159
525
300
225
50
90
100 PN10
158
180
220
18
575
190
385
285
136
149
525
300
225
45
112
100 PN10
158
180
220
18
625
190
435
315
156
159
550
300
250
73
100
100 PN10
158
180
220
18
615
190
425
315
156
159
550
300
250
66
132
100 PN10
158
180
220
18
730
190
540
360
176
184
600
320
280
106
132
100 PN10
158
180
220
18
730
190
540
360
176
184
600
320
280
96
132
100 PN10
158
180
220
18
730
190
540
320
136
184
525
300
225
91
132
100 PN10
158
180
220
18
730
190
540
320
136
184
525
300
225
84
132
100 PN10
158
180
220
18
730
190
540
320
136
184
525
300
225
76
200
100 PN10
158
180
220
18
995
190
805
413
156
257
550
300
250
213
200
100 PN10
158
180
220
18
995
190
805
413
156
257
550
300
250
195
180
100 PN10
158
180
220
18
890
190
710
386
156
230
550
300
250
153
160
100 PN10
158
180
220
18
890
190
710
386
156
230
550
300
250
135
200
100 PN10
158
180
220
18
995
190
805
433
176
257
600
320
280
220
120
A2LD - A4LD
CIRCULATION PUMPS
A2L - A4L - CIRCULATION PUMPS
Applications
- Heating and air-conditioning systems
- Water lifting from lakes , rivers, wells, etc.
- Irrigation systems on ground surface or by sprinkling.
- Water supply and distribution for isolated houses or small villages.
- Pressure systems.
- Industrial services.
- Domestic hot water supply systems.
Construction features
It is a single impeller centrifugal pump coupled by a spindle to a totally
enclosed asynchronous motor. The motor cooling is obtained by means
of external ventilation. The shaft seal is of the mechanical type.
Twin construction. Performance data as given on the guidelist and on
the nameplate refer to continuous duty and clear water ( specific
Weight: 1000 Kg / m3 ) with a manometric suction head of 2 meters.
Installation
Since suction and delivery are in-line, pump can be installed in line
with the piping, either horizontally or vertically. Do not install the pump
with motor facing downwards.
On request the pumps can be supplied with flanged counterflanges.
Construction materials
- Pump casing : Cast iron
- Impeller : Cast iron
- Shield, lantern, cover: cast iron
- Shaft: Stainless steel
Pump working limits
- Max working pressure: 10 bar .
- Max liquid temperature: +130 C .
- Min. liquid temperature : -10 C
- Max ambient temperature : +40 C
- Max liquid viscosity : 5 E.
Motor
Asynchronous Threephase motor.
- Protection: IP 54
- Standard voltages:
50 Hz: V. 220 - 400 ( +-10 % )
- Insulation: Class F
Tolerances
- Pump: ISO 2548 class C annex B.
- Motor: according to CEI standards.
A2LD
A4LD
H
[m]
H
[m]
50
20
15
40
30
50-160
25
20
65-160
10
8
6
5
4
80-160
100-200
50-125
40-125
15
80-160
65-160
40-125
50-125
3
2
10
8
6
1
0,8
0,6
0,5
5
4
100-200
50-160
12
24
60
120
180 240
Q [m3/h]
0,6
121
1,2
12
24
60
120
180
Q [m3/h]
A2LD -A4LD 40
CIRCULATION PUMPS
Motor
Power
MODEL
(Kw)
N8020800 A4LD 40 - 125 Y
40
50
75
m /h 2,4
4,5
L/1'
Amp.
n
Q
-1
3x400V 3x230V (min )
3
0,25
0,85
1,46
0,25
0,85
1,46
4 poli
0,75
1,9
3,3
2 poli
1,0
2,4
4,4
2 poli
1,5
3,6
6,2
2 poli
4 poli
Discharge Head
in meters
CODE
4,6 4,5
4,1
6,2
6,0
7,5
3,6 3,0
2,2
5,8 5,2
4,5
10,5
12
13,5 15
9,5
20,5 20
19
21
3,9 3,0
24,5 24 23,5
18
18
17
16
15 11,5 7,5
23
22
21
20 16,5 13
MODEL
MOTOR
DN
n d holes e
DN : Flanges
FLANGES mm.
DNa
DNm
WEIGHT (kg)
A4LD 40 - 125 X
71
40 PN10
88
110
150
18
425
100
325
397
200
197
340
130
210
100
41
A4LD 40 - 125 Y
71
40 PN10
88
110
150
18
425
100
325
397
200
197
340
130
210
100
41
A2LD 40 - 125 A
80
40 PN10
88
110
150
18
445
100
345
397
200
197
340
130
210
100
54
A2LD 40 - 125 B
80
40 PN10
88
110
150
18
445
100
345
397
200
197
340
130
210
100
52
A2LD 40 - 125 C
71
40 PN10
88
110
150
18
425
100
325
397
200
197
340
130
210
100
50
122
A2LD -A4LD 50
CIRCULATION PUMPS
MODEL
Motor
Power
(Kw)
N8020820 A4LD 50 - 125 X
L/1' 100 125 150 175 200 225 250 300 350 400 450 500 600
Amp.
n
-1
Q
3x400V 3x230V (min )
3
6
m /h
1,15
0,37
7,5
9 10,5 12 13,5 15 18
21 24 27 30
4 poli
0,5
1,6
2,8
4 poli
1,5
3,6
6,2
2 poli
2,0
4,4
7,7
2 poli
3,0
6,4
11
2 poli
3,0
6,4
11
2 poli
4,0
8,8
15,2
2 poli
Discharge Head
in meters
CODE
PRICE
36
22 20,5 17
28 26,5 25
23
18
27
MODEL
MOTOR
DN
n d holes e
DN : Flanges
FLANGES mm.
DNa
DNm
a
WEIGHT (kg)
A4LD 50 - 125 X
71
50 PN10 102
125
165
18
435
110
325
427
217
210
365
145
220
105
46
A4LD 50 - 160 X
71
50 PN10 102
125
165
18
435
110
325
480
245
235
410
170
240
120
52
A2LD 50 - 125 A
90
50 PN10 102
125
165
18
495
110
385
427
217
210
365
145
220
105
66
A2LD 50 - 125 B
80
50 PN10 102
125
165
18
455
110
345
427
217
210
365
145
220
105
58
A2LD 50 - 125 C
80
50 PN10 102
125
165
18
455
110
345
427
217
210
365
145
220
105
56
A2LD 50 - 160 A
80
50 PN10 102
125
165
18
455
110
345
427
217
210
365
145
220
105
56
A2LD 50 - 160 B
100
50 PN10 102
125
165
18
535
110
425
480
245
235
410
170
240
120
86
123
A2LD -A4LD 65
CIRCULATION PUMPS
CODE
MODEL
Motor
Power
(Kw)
L/1' 200 225 250 300 350 400 450 500 600 700 800 900 1000
Amp.
n
Q
-1
3x400V 3x230V (min )
m3/h 12 13,5 15 18 21 24 27 30 36 42 48 54 60
0,55
1,6
2,7
4 poli
0,75
3,5
4 poli
0,9
2,4
4,2
4 poli
6,4
11
2 poli
8,8
15,2
2 poli
5,5
11,3
2 poli
7,5
17,3
2 poli
Discharge Head
in meters
PRICE
35
26 23,5
34 32,5 31
29
MODEL
MOTOR
DN
n d holes e
DN : Flanges
FLANGES mm.
DNa
DNm
WEIGHT (kg)
A4LD 65 - 160 X
80
65 PN10
122
145
185
18
475
130
345
543
275
268
450
180
270
140
67
A4LD 65 - 160 Y
80
65 PN10
122
145
185
18
475
130
345
543
275
268
450
180
270
140
65
A4LD 65 - 160 Z
80
65 PN10
122
145
185
18
475
130
345
543
275
268
450
180
270
140
65
A2LD 65 - 160 A
90
65 PN10
122
145
185
18
495
110
385
480
245
235
410
170
240
120
67
A2LD 65 - 160 B
132
65 PN10
122
145
185
18
670
130
540
543
275
268
450
180
270
140
125
A2LD 65 - 160 C
100
65 PN10
122
145
185
18
565
130
435
543
275
268
450
180
270
140
101
A2LD 65 - 160 D
90
65 PN10
122
145
185
18
485
130
345
543
275
268
450
180
270
140
81
124
A2LD -A4LD 80
CIRCULATION PUMPS
CODE
Motor
Power
MODEL
(Kw)
N8020870 A4LD 80 - 160 W
L/1' 300 350 400 450 500 600 700 800 900 1000 1250 1500 1750 2000 2250
Amp.
n
Q
3x400V 3x230V (min-1)
m3/h 18 21 24 27 30 36 42 48 54 60 75 90 105 120 135
2,25
3,9
4 poli
0,9
2,7
4,7
4 poli
1,1
2,6
4,5
4 poli
1,5
3,5
6,1
4 poli
7,5
17,3
2 poli
10
22,5
2 poli
12,5
27
2 poli
15
32
2 poli
Discharge Head
in meters
0,75
PRICE
23
19
29
24
30
MODEL
MOTOR
DN
n d holes e
DN : Flanges
FLANGES mm.
DNa
DNm
WEIGHT (kg)
A4LD 80 - 160 X
90
80 PN10
138
160
200
18
535
150
385
550
280
270
510
205
305
135
83
A4LD 80 - 160 Y
90
80 PN10
138
160
200
18
535
150
385
550
280
270
510
205
305
135
79
A4LD 80 - 160 Z
80
80 PN10
138
160
200
18
485
150
335
550
280
270
510
205
305
135
74
A4LD 80 - 160 W
80
80 PN10
138
160
200
18
485
150
335
550
280
270
510
205
305
135
72
A2LD 80 - 160 A
112
80 PN10
138
160
200
18
565
130
435
543
275
268
450
180
270
140
110
A2LD 80 - 160 B
132
80 PN10
138
160
200
18
690
150
540
550
280
270
510
205
305
135
175
A2LD 80 - 160 C
132
80 PN10
138
160
200
18
690
150
540
550
280
270
510
205
305
135
162
A2LD 80 - 160 D
132
80 PN10
138
160
200
18
690
150
540
550
280
270
510
205
305
135
141
125
CIRCULATION PUMPS
CODE
MODEL
Motor
Power
(Kw)
L/1' 500
Amp.
n
-1
3x400V 3x230V (min ) Q 3
m /h 30
600 700 800 900 1000 1100 1200 1300 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000
36
42
48
54
60
66
72
78
6,5
5,3 4,6
90
105 120 135 150 165 180 195 210 225 240
N8020910
1,5
3,8
6,6
4 poli
N8020920
2,2
5,1
8,9
4 poli
N8020930
3,0
6,9
12
4 poli
N8020940
4,0
9,2
16
4 poli
N8020760
10
38
2 poli
N8020770
12,5
44,5
2 poli
N8020780
15
58
2 poli
N8020790
15
71
2 poli
N8020740
12,5
27
2 poli
32,1 31 29 27 24,5 22 19
N8020750
15
32
2 poli
37,3 36,5 35 33
20 17,5 15
12 8,6
31 28,5 26
MODEL
MOTOR
DN : Flanges
DN
n d holes e
FLANGES mm.
DNa
DNm
WEIGHT (kg)
112
100 PN10
158
180
220
18
615
180
435
670
325
345
630
240
390
165
150
100
100 PN10
158
180
220
18
605
180
425
670
325
345
630
240
390
165
138
100
100 PN10
158
180
220
18
605
180
425
670
325
345
630
240
390
165
130
90
100 PN10
158
180
220
18
535
180
355
670
325
345
630
240
390
165
110
132
100 PN10
158
180
220
18
720
180
540
670
325
345
630
240
390
165
162
132
100 PN10
158
180
220
18
720
180
540
670
325
345
630
240
390
165
162
132
100 PN10
158
180
220
18
720
180
540
670
325
345
630
240
390
165
162
132
100 PN10
158
180
220
18
720
180
540
670
325
345
630
240
390
165
162
132
100 PN10
158
180
220
18
720
180
540
670
325
345
630
240
390
165
162
132
100 PN10
158
180
220
18
720
180
540
670
325
345
630
240
390
165
162
126
DESCRIPTION
MATERIAL
UNION
(PIPE END)
RING NUT
B7012KKK
3/4F
1 1/2
B7016KKK
3/4F
1 1/4
B7013KKK
1F
1 1/2
1F L
1 1/2
B7014KKK
1 1/4 M
1 1/2
B7015KKK
1 1/4 F
B7009KKK
PRICE
Brass
CIRCULAR FLANGES
CODE
MATERIAL
DESCRIPTION
B7058KKK
TYPE
To be
welded
B7098KKK
B7047KKK
Threaded
B7097KKK
B7059KKK
To be
welded
ZB901890
B7048KKK
B
Threaded
B7050KKK
B7060KKK
B7075KKK
Fig. 1
Steel
B7049KKK
B7051KKK
B7061KKK
To be
welded
Threaded
To be
welded
ZB901910
B7054KKK
Threaded
ZB901900
B7062KKK
To be
welded
ZB901920
SPEC
N F
PN
100
14
PN 6
DN 40 UNI 2280
110
19
PN 16
DN 40 UNI 2282
100
14
PN 6
11/2
UNI 2253
110
19
PN 16
1 /2
UNI 2254
110
14
PN 6
DN 50 UNI 2280
145
18
PN 16
DN 50 UNI 2282
110
14
PN 6
UNI 2253
125
18
PN 16
UNI 2254
130
14
PN 6
DN 65 UNI 2280
145
18
PN 16
DN 65 UNI 2282
130
14
PN 6
21/2
UNI 2253
125
18
PN 16
2 /2
UNI 2254
150
19
PN 6
DN 80 UNI 2280
160
18
PN 16
DN 80 UNI 2282
150
18
PN 6
UNI 2253
160
18
PN 16
UNI 2254
170
19
180
18
DN
PRICE
BLIND FLANGES
MATERIAL
INT
N F
Fe 360
105
G20
133,5
8,5
B7230KKK
G20
180
11
ZB901860
Fe 360
112
CODE
DESCRIPTION
B7241KKK
B7231KKK
Blind Flange
128
PRICE
BRASS UNIONS
ACCESSORY
CIRCULAR FLANGES
BRASS UNIONS
CIRCULAR FLANGES
Ring nut
3 DN 80 DN 80 DN 100 DN 100
B7241KKK
B7230KKK
B7231KKK
ZB901860
B7062KKK
ZB901920
B7061KKK
ZB901910
ZB901900
B7054KKK
B7051KKK
B7049KKK
B7075KKK
B7060KKK
ZB901890
B7059KKK
B7050KKK
B7048KKK
B7058KKK
B7098KKK
B7047KKK
B7097KKK
B7015KKK
B7014KKK
B7009KKK
B7013KKK
B7016KKK
B7012KKK
CODE
BLIND FLANGES
2 DN 50 DN 50 DN 65 DN 65 21/2 21/2
PN 16 PN 6 PN 16 PN 6 PN 6 PN 16 PN 6 PN 16 PN 6 PN 16 PN 6 PN 16 PN 6 PN 16 PN 16 PN 6 PN 16 PN 6
Nom. Pressure
TYPE
BLIND FLANGES
SR3
SR3/RS2 25
R2X 20
R2B 30
R2B 32/R2B 40
R2S (D) 32
R2S (D) 40
R2S 40 F
R2S (D) 42 F
R2C/R4C (D) 40
R2T/R4T (D) 50
A2L/A4L (D) 65
A2L/A4L (D) 80
A2L/A4L (D) 100
"PREVIOUS MODEL
129
A2L/A4L (D) 50
"
A2L/A4L (D) 40
"
"
R2T/R4T (D) 40
DRENOX
12
10
Motor
- Dry motor with stainless steel casing
- Level of protection IP68
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Three phase power supply with external protection
provided by the user
- Completely insulated cable connection chamber
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
/1 2
250
/10
16
0/ 8
80
/7
Usage Limitations
- Type of liquid: partially effluent and dirty clear water,
non-aggressive liquids
- Maximum liquid temperature 40C
- Maximum submersion under the water level 7m
- Minimum drainage level 3 mm for model 80/7, 35 mm
for the remaining models (manual version)
- Free clearance of solids 3 mm for models 80/7, 6 mm
for the remaining models
350
2
Hm
Q
50
3
L / 1'
m3/ h
250
15
200
12
150
9
100
6
300
18
Applications
- Drainage of seepage water, pumping of rain water,
from a grating or drain, pumping of domestic waste
water, drainage of environments, bathing and
swimming pools, industrial applications
- Fountains and water features
- Surface irrigation
Dimensions mm.
Model
B
Weight
Free Clearance
DNM
kg.
1/4"
5,7
6,5
DRENOX 80/7
231
61
177
DRENOX 160/8
300
94
177
1 1/4"
1/4"
DRENOX 250/10
338
94
177
DRENOX 350/12
338
94
177
1 1/4"
MODEL
N1031010
N1031050
N1031090
N1031100
N1031020
N1031060
N1031030
N1031070
N1031040
N1031080
DRENOX 80/7 N *
DRENOX 80/7 N AUT *
DRENOX 80/7
DRENOX 80/7 AUT
DRENOX 160/8
DRENOX 160/8 AUT
DRENOX 250/10
DRENOX 250/10 AUT
DRENOX 350/12
DRENOX 350/12 AUT
N1031110
DRENOX 350/12 T
Nominal
Power
Absorbed
Power
L/1'
VOLTAGE
Amp.
F.
m /h
HP
kW
HP
kW
0,3
0,2
0,4
0,3
1 ~ 220 240 V
1,3
6,3
0,3
0,2
0,4
0,3
1 ~ 220 240 V
1,3
6,3
0,55
0,40
0,75
2,4
0,75
0,55
1,2
0,9
1 ~ 220 240 V
4,5
10
1,1
0,8
1,6
1,2
1 ~ 220 240 V
5,1
16
1,1
0,8
1,6
1,2
3 ~ 400 V
* TECHNOPOLYMER IMPELLER
132
10
40
60
80
0,6
2,4
3,6
4,8
7,2
6,5
6,5
5,8
4,1
2,2
9,4
8,5
7,6
7,2
5,1
4,1
10,5
10
9,5
7,7
6,5
3,4
10,5
10
9,5
7,7
6,5
3,4
Discharge Head
in meters
CODE
7
8,5
PRICE
9,6 14,4
18
OMNIA
6
20
0/8
16
Motor
- Dry motor with stainless steel casing
- Level of protection IP68
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Completely insulated cable connection chamber
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
0/7
4
80
/5
2
Hm
Usage Limitations
- Type of liquid: waste water with solids
- Maximum liquid temperature 40C
- Maximum submersion under the water level 7m
- Minimum drainage level 35 mm (manual)
- Free clearance of solids 20 mm
100
6
50
3
L / 1'
m3/ h
150
9
200
12
Applications
- Pumping of domestic waste water, draining of
environments, bathing and swimming pools, industrial
applications
- Fountains and water features
- Surface irrigation
Dimensions mm.
Model
A
Weight
Free Clearance
DNM
kg
1 /4 "
6,1
OMNIA 80/5
264
94
177
20
OMNIA 160/7
300
94
177
20
1 1 /4 "
20
1 /4 "
CODE
338
MODEL
94
Nominal
Power
Absorbed
Power
HP
kW
HP
kW
VOLTAGE
177
Amp. F.
N2081070
N2081090
OMNIA 80/5
OMNIA 80/5 AUT
0,3
0,2
0,4
0,3
1 ~ 220 240 V
1,4
N2081020
N2081110
OMNIA 160/7
OMNIA 160/7 AUT
0,5 0,37
0,7
0,5
1 ~ 220 240 V
2,5
N2081030
N2081100
OMNIA 200/8
OMNIA 200/8 AUT
0,7
3,2
0,5
* TECHNOPOLYMER IMPELLER
133
8,5
L/1'
10
40
70
100
140
200
m3/h
0,6
2,4
4,2
8,4
12
4,1
2,7
5,5
2,8
7,8
6,3
5,4
4,1
2,7
PRICE
Discharge Head
in meters
OMNIA 200/8
0,5
SOM
DNM
Applications
- Marble processing industry, quarries, ceramics, paper
mills and in agriculture for handling sewage and
surface irrigation and for all typical building applications
- Draining of muddy and marshy land
D
SOM
Dimensions mm.
Model
Weight
DNM
kg
SOM 2 B
110
690
295
290
3"
54
SOM 2 A
110
690
295
290
3"
55
SOM 3
110
740
295
290
3"
60
MODEL
Nominal
Power
Absorbed
Power
HP
kW
HP
kW
L/1'
VOLTAGE
Amp.
m /h
N1061010
SOM 2 B
2,2
3,8
2,8
3 ~ 400 V
5,2
N1062010
SOM 2 A
2,2
3,8
2,8
3 ~ 400 V
5,2
N1063010
SOM 3
4,8
3,5
3 ~ 400 V
134
Discharge Head
in meters
CODE
PRICE
12
24
36
48
60
6,7
2,5
9,5
5,7
12
7,5
5,7
3,7
72
PRIOX
14
12
10
8
30
11
13
13
0/
0/
25
Applications
All applications of pumping and draining effluent, civil
and industrial sewage with suspended solids
Pumping stations with one or more pumps for civil
and industrial plants
0/
0/
0/
46
42
Usage Limitations
Type of liquid: waste water and sewage with solids
Maximum liquid temperature 40C.
Maximun submersion under the water level 7m
Minimum drainage level 60 mm (manual version)
Free clearance of solids 40 mm
(PRIOX 600/13 - 50mm)
60
Hm
Q
100
6
L / 1'
m3/ h
200
12
400
24
300
18
Dimensions mm.
Model
600
36
500
30
Weight
Free Clearance
DNM
kg
PRIOX 250/8
420
122,5
235
40
1"1/2
9,4
PRIOX 300/9
420
122,5
235
40
2"
9,6
PRIOX 420/11
450
122,5
235
40
2"
11,2
PRIOX 460/13
450
122,5
235
40
2"
11,7
450
122,5
235
50
2"
12,6
PRIOX 600/13
MODEL
Nominal
Power
HP
N2110100
N2110110
PRIOX 250/8 M
PRIOX 250/8 M AUT
N2110040
N2110050
PRIOX 300/9 M
PRIOX 300/9 M AUT
0,8
N2110090
N2110020
N2110030
N2110080
N2110000
N2110010
N2110070
PRIOX 300/9 T
PRIOX 420/11 M
PRIOX 420/11 M AUT
PRIOX 420/11 T
PRIOX 460/13 M
PRIOX 460/13 M AUT
PRIOX 460/13 T
0,8
1,2
N2110060
PRIOX 600/13 T
kW
Absorbed
Power
HP
VOLTAGE
Amp.
F.
L/1'
50
12
15
m /h
kW
1,0
0,7
1 ~ 230 V
0,6
1,2
0,9
0,6
1,2
0,6
0,9
1,8
1,2
0,9
1,6
PRICE
18
24
3,15
14,0
6,5
5,2
3,4
2,0
0,2
1 ~ 230 V
4,1
12,5
7,7
6,4
3,8
2,3
3 ~ 400 V
1,55
7,7
6,4
3,8
2,3
1,3
1 ~ 230 V
10
7,8
6,3
3,8
1,8
1,3
3 ~ 400 V
2,3
1,2
2,3
1,7
1 ~ 230 V
7,5
8,5
5,5
1,6
1,2
2,3
1,7
3 ~ 400 V
2,7
1,8
1,3
2,5
1,8
3 ~ 400 V
0,7
0,5
20
20
Discharge Head
in meters
CODE
135
5,5
30
33
1,8
MINIVORT P
12
P2
-2
10
P21 ,5
P2 -
1
P 4 -1
6
4
Usage Limitations
- Type of liquid: waste water and sewage
- Maximum liquid temperature 40C
- Maximum submersion under the water level 7m
- Minimum drainage level 45mm (manual version)
- Free clearance of solids 52 mm
2
Hm
Q
100
6
L / 1'
m3/ h
200
12
400
24
300
18
700
42
DNM
Applications
- Pumping and draining effluent; civil and industrial
sewage with suspended solids
- Draining of cesspits, cesspools, handling of effluent
- Pumping stations with one or more pumps
for civil and industrial plants
600
36
500
30
Dimensions mm.
Model
Weight
DNM
kg
MINIVORT P2 - 1
45
440
85
235
2"
27
MINIVORT P2 - 1,5
45
440
85
235
2"
27
MINIVORT P2 - 2
45
440
85
235
2"
28
MINIVORT P4 - 1
45
440
85
235
2"
27
MODEL
Nominal
Power
Absorbed
Power
L/1'
VOLTAGE
Amp.
F.
m /h
HP
kW
HP
kW
0,75
1,5
1 ~ 220 240 V
1 ~ 220 240 V
3 ~ 400 V
6,5
6,5
2,3
20
20
N2041010
N2041020
N2041030
MINIVORT P2 - 1 M
MINIVORT P2 - 1 M AUT
MINIVORT P2 - 1 T
N2042010
N2042020
N2042030
MINIVORT P2 - 1,5 M
MINIVORT P2 - 1,5 M AUT 1,5
MINIVORT P2 - 1,5 T
1,1
2,2
1,6
1 ~ 220 240 V
1 ~ 220 240 V
3 ~ 400 V
7
7
2,7
25
25
N2043010
N2043020
N2043030
MINIVORT P2 - 2 M
MINIVORT P2 - 2 M AUT
MINIVORT P2 - 2 T
1,5
2,2
1 ~ 220 240 V
1 ~ 220 240 V
3 ~ 400 V
9,8
9,8
3,2
35
35
N2044010
N2044020
N2044030
MINIVORT P4 - 1 M
MINIVORT P4 - 1 M AUT
MINIVORT P4 - 1 T
0,75
1,7
1 ~ 220 240 V
1,25 1 ~ 220 240 V
3 ~ 400 V
5,5
5,5
2,3
25
25
136
50
Discharge Head
in meters
CODE
PRICE
30
12
18
24
5,4
4,1
8,3
7,5
6,1
4,6
2,8
3,7
4,6
3,3
2,2
MINIVORT PP
10
Motor
- Dry motor
- Level of protection IP68
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal protection built
into the motor winding
- Three phase power supply with external protection
provided by the user
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
PP
2-2
6
PP
2 -1
,5
PP
2-1
4
2
Usage Limitations
- Type of liquid: waste water and sewage
- Maximum liquid temperature 40C
- Maximum submersion under the water level 7m
- Minimum drainage level 72mm (manual version)
- Free clearance of solids 58 mm
Hm
Q
L / 1'
m3/ h
100
6
200
12
300
18
600
36
400 500
24
30
800
48
900
54
DNM
Applications
- Pumping and draining effluent; civil and industrial
sewage with suspended solids
- Draining of cesspits, cesspools, handling of effluent
- Pumping stations with one or more pumps
for civil and industrial plants
- On request, connecting foot to facilitate
installations and maintenance
700
42
Dimensions mm.
Model
MINIVORT PP2 - 1
Weight
DNM
Kg
72
475
115
325
2 1/2"
30
1/2"
31
33
72
475
115
325
MINIVORT PP2 - 2
72
475
115
325
2 1/2"
MODEL
Absorbed
power
HP
kW
HP
kW
L/1'
VOLTAGE
Amp.
F.
MINIVORT PP2 - 1 M
MINIVORT PP2 - 1 M AUT
MINIVORT PP2 - 1 T
0,75
1,5
1 ~ 220 240 V
1 ~ 220 240 V
3 ~ 400 V
6,2
6,2
2,3
20
20
N2052010
N2052020
N2052030
1,2
2,5
1,8
1 ~ 220 240 V
1 ~ 220 240 V
3 ~ 400 V
8,2
8,2
3
25
25
N2053010
N2053020
N2053030
MINIVORT PP2 - 2 M
MINIVORT PP2 - 2 M AUT
MINIVORT PP2 - 2 T
1,5
2,2
1 ~ 220 240 V
1 ~ 220 240 V
3 ~ 400 V
9,8
9,8
3,5
35
35
PRICE
3
m /h
N2051010
N2051020
N2051030
137
Discharge Head
in meters
CODE
Nominal
Power
12
18
24
1,6
6,7
5,7
4,6
3,3
10
9,3
8,2
4,2
36
48
SOMVORT
Motor
- Motor in dielectric oil bath
- Level of protection IP68
- Class F insulation
- Cable connection chamber in oil bath
- Three phase power supply with external protection
provided by the user
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
- Suitable for continuous use
SOM
VOR
T
4
Usage Limitations
- Type of liquid: suspended and also fibrous solids
- Maximum liquid temperature 40C
- Maximum submersion under the water level 7m
- Minimum drainage level 105mm (manual version)
- Free clearance of solids 75 mm
Hm
Applications
- Pumping and draining effluent, civil and industrial
sewage with suspended solids
- Draining of cesspits, cesspools, handling of effluent
- Pumping stations with one or more pumps for civil
and industrial plants
L / 1'
m3/ h
100
6
300
18
700
42
500
30
900
54
1100
66
DNM
Dimensions mm.
Model
SOMVORT
CODE
N2061010
MODEL
SOMVORT
Weight
DNM
kg
105
710
250
290
3"
56
Nominal
Power
Absorbed
Power
HP
kW
HP
kW
4,8
3,5
L/1'
VOLTAGE
Amp.
PRICE
3
3 ~ 400 V
138
Q
m /h
18
30
42
54
Discharge
Head
in meters
5,5
4,5
3,5
2,5
Screw impeller
139
VITEX SB
Free Bore
(mm.)
B2
K1
P2
Q (nx)
WEIGHT
(kg)
AC 50/2 SB
52
2"
237
518
53
260
3 x 18
400
233
465
36
30
AD 50/2 SB
52
2"
237
518
53
260
3 x 18
400
233
465
38
28
AC 55/2 SB
50
50
165
237
518
53
260
3 x 18
400
280
465
36
30
AD 55/2 SB
50
50
165
237
518
53
260
3 x 18
400
280
465
38
28
CODE
F2602KKK
MODEL
Electric cable
l/1' 0
Mot. Pow. VOLTAGE
n
Amp.
(V) 1x230V 3x400V (rpm) (n.cond. x cable) Q m3/h 0
HP kW
direct
Y/
1x230
3x400
F2600KKK
1x230
2,3
2900 4x1,5+
5,5
2,5
2900 4x1,5+
5,2
2,3
2900 4x1,5+
5,5
2,5
2900 4x1,5+
3x400
F2570KKK
1x230
F2571KKK
F2572KKK
3x400
F2580KKK
1x230
5,2
3x400
140
50
3
11,2 10,5
Diacharge Head
in meters
MODEL
12
18
24
27
2,9 1,8
3,4 2,2
11,2 10,5
2,9 1,8
3,4 2,2
PRICE
VITEX AC-AD
141
MODEL
WEIGHT
(kg)
Free Bore
(mm.)
B2
K1
P2
Q (nx)
CD 80/2 SB
95
80
200
315
838
63
360
3 x 18
650
377
725
124
58
CE 80/2 SB
95
80
200
315
967
113
360
3 x 18
650
377
854
235
60
CD 80/4 SB
95
80
200
315
674
113
360
3 x 18
650
377
561
75
58
CE 80/4 SB
95
80
200
315
838
113
360
3 x 18
650
377
725
107
60
Electric cable
(n.cond. x cable)
direct
Y/
n
(rpm)
3x400/
F2607KKK-B CD 80/2 SB 9,00 6,50
690
16,0
2900
4x4+
2x4x2,5+
35,0
2900 4x10+
2x4x2,5+
2,4
1450 4x1,5+
5,3
1450 4x2,5+
MODEL
142
l/1'
m3/h
30
60
90
Discharge Head
in meters
Amp.
3x400 V
CODE
8,5 5,2
11,5
8,3
1,5
5,4 2,8
PRICE
VITEX CD-CE
143
MODEL
WEIGHT
(kg)
Free Bore
(mm.)
B2
K1
P2
Q (nx)
DE 100/2 SB
100
100
224
370
1021
117
435
3 x 18
650
433
904
258
75
DE 100/4 SB
100
100
224
370
892
117
435
3 x 18
650
433
775
129
75
DG 100/4 SB
100
100
224
370
892
117
435
3 x 18
650
433
775
144
78
MODEL
Electric cable
(n.cond. x cable)
direct
Y/
Amp.
3x400 V
n
(rpm)
3x400/
690
40,0
2900
6,0
1450 4x2,5+
8,0
1450 4x2,5+
4x10+
144
l/1' 0
m3/h 0
2x4x6+
60
90
Discharge Head
in meters
CODE
12,8 11,2
8,2
6,0 4,3
2,4
7,8
3,0
5,2
8,0
PRICE
VITEX DE-DG
145
MODEL
WEIGHT
(kg)
Free Bore
(mm.)
B2
K1
P2
Q (nx)
EF 125/4 SB
150
125
250
490
1039
172
570
3 x 18
750
585
867
210
73
EM 125/4 SB
150
125
250
490
1172
172
570
3 x 18
750
585
1000
300
95
EP 125/4 SB
150
125
250
490
1172
172
570
3 x 18
750
585
1000
320
93
MODEL
Amp.
3x400 V
n
(rpm)
Electric cable
(n.cond. x cable)
direct
Y/
3x400/
690
11,5
1450
4x4+
2x4x2,5+
3x400/
690
17,5
1450
4x4+
2x4x2,5+
F2651KKK-B
3x400/
690
25,0
1450
4x6+
2x4x4+
F2641KKK-B
146
l/1'
m3/h
0
0
16,4 12,0
Discharge Head
in meters
CODE
9,0
4,4
7,5 4,0
4,8
PRICE
VITEX EF-EM-EP
147
Screw impeller
149
VITEX SP
MODEL
A
B1 B3 D
E E1 F1 F2 F3 F4
WEIGHT
(kg)
Free Bore
(mm.)
AC 55/2 SP
50 50 165 237 200 93 128 552 30011/4" 524 59 312 180 220 3 x 400 280 465
18
58
30
AD 55/2 SP
50 50 165 237 200 93 128 552 30011/4" 524 59 312 180 220 3 x 400 280 465
18
60
28
CODE
MODEL
Electric cable
Mot. Pow. VOLTAGE
l/1'
n
Amp.
(n.cond. x cable) Q
HP kW (V)
1x230 V 3x400 V (rpm) direct
m3/h
Y/
1x230
F2576KKK
F2577KKK
3x400
F2585KKK
1x230
F2586KKK
F2587KKK
3x400
5,2
2,3
2900 4x1,5+
5,5
2,5
2900 4x1,5+
50
12
18
24
27
7,5
5,2
2,9
1,8
6,4
3,4
2,2
F2575KKK
*Note: the connecting foot is not included in the price, see page 158
150
PRICE
VITEX AC-AD
151
MODEL
A
B1 B3 D
E E1 F1 F2 F3 F4 H
K1 M
WEIGHT
(kg)
Free Bore
(mm.)
CD 80/4 SP
95 100 224 315 250100 160 704 415 11/2" 842 113 402 200 250 3 x 650 377 725
18
82
58
CE 80/4 SP
95 100 224 315 250100 160 704 415 11/2" 892 113 402 200 250 3 x 650 377 775
18
114
60
CODE
MODEL
Amp.
3x400 V
Electric cable
l/1' 0
n
(n.cond. x cable) Q
(rpm) direct
m3/h 0
Y/
2,4
1450 4x1,5+
F2614KKK-B
5,3
1450 4x2,5+
15
8,5 7,2
30
45
60
75
90
5,2 3,4
1,5
8,3 6,7
5,4 3,9
2,8
Discharge Head
in meters
F2612KKK-B
11,5
9,8
152
PRICE
VITEX CD-CE
153
MODEL
A
B1 B3 D
E E1 F1 F2 F3 F4 H
Free Bore
(mm.)
WEIGHT
(kg)
DE 100/4 SP
100 100 224 370 250 100 160 760 415 11/2" 857 82 458 200 250 3 x 650 433 775
18
154
75
DG 100/4 SP
100 100 224 370 250 100 160 760 415 11/2" 857 82 458 200 250 3 x 650 433 775
18
169
78
CODE
MODEL
Amp.
3x400 V
n
(rpm)
Electric cable
(n.cond. x cable)
direct
Y/
6,0
1450 4x2,5+
8,0
1450 4x2,5+
l/1' 0
m3/h 0
12,8 11,2
60
90
120 150
8,2
6,0 4,3
2,4
7,8
3,0
Discharge Head
in meters
5,2
PRICE
VITEX DE-DG
155
MODEL
A B1 B3 D
E E1 F1 F2 F3 F4
Free Bore
(mm.)
WEIGHT
(kg)
EF 125/4 SP
150 125 250 490 250 105 175 945 550 11/2" 949 82 610 200 250 3 x 750 585
18
867
245
73
EM 125/4 SP
150 125 250 490 250 105 175 945 550 11/2"1082 82 610 200 250 3 x 750 585 1000
18
335
95
EP 125/4 SP
150 125 250 490 250 105 175 945 550 11/2"1082 82 610 200 250 3 x 750 585 1000
18
355
93
n
(rpm)
Electric cable
(n.cond. x cable)
direct
Y/
3x400/
690
11,5
1450
4x4+
2x4x2,5+
17,5
1450
4x4+
2x4x2,5+
25,0
1450
4x6+
2x4x4+
F2642KKK-B
F2652KKK-B
MODEL
0
0
16,4 12,0
9,0
4,4
7,5 4,0
*
156
l/1'
m3/h
Discharge Head
in meters
Amp.
3x400 V
CODE
4,8
PRICE
VITEX EF-EM-EP
157
Screw impeller
159
VITEX OM
A1
A2
Free Bore
(mm.)
AC 50/2 OM - TM
472
360
83
2"
2"
180
40
110
20
295
270
300
11
30
AD 50/2 OM - TM
472
360
83
2"
2"
180
40
110
20
295
270
300
11
28
AC 55/2 OM - TM
499
360
100
50
50
180
40
160
20
295
270
300
11
30
AD 55/2 OM - TM
499
360
100
50
50
180
40
160
20
295
270
300
11
28
MODEL
MODEL
Mot. Pow.
HP kW
F2662KKK
VOLTAGE
(V)
n
(rpm)
l/1'
m3/h
50
12
18
24
27
1x230
AC 50/2 OM - TM 1,00 0,75
F2663KKK
4,85
1,75
2900
11,2 10,5
9,6 7,5
5,2
2,9
1,8
5,5
2,5
2900
6,4
3,4
2,2
5,2
2,3
2900
11,2 10,5
9,6 7,5
5,2
2,9
1,8
5,5
2,5
2900
6,4
3,4
2,2
3x400
F2660KKK
1x230
AD 50/2 OM - TM 1,50 1,10
F2661KKK
3x400
F2664KKK
1x230
AC 55/2 OM - TM 1,00 0,75
F2665KKK
3x400
F2666KKK
1x230
AD 55/2 OM - TM 1,50 1,10
F2667KKK
Amp.
1x230 V
3x400 V
Discharge Head
in meters
CODE
3x400
160
PRICE
VITEX AC-AD
161
A1
A2
Free Bore
(mm.)
CD 80/4 OM - TB
650
500
106
80
100
233
60
217
25
450
395
430
14
58
CE 80/4 OM - TB
688
500
106
80
100
233
60
217
25
450
395
430
14
60
MODEL
CODE
MODEL
Mot. Pow.
HP kW
VOLTAGE
(V)
Amp.
3x400 V
n
(rpm)
CD 80/4 OM - TB
1,50 1,10
3x400
2,8
1450
F2672KKK
CE 80/4 OM - TB
3,00 2,20
3x400
5,5
1450
l/1' 0
m3/h 0
30
45
60
8,5 7,5
5,2
3,4 1,5
11,5 9,8
8,3
6,7 5,4
75
90
Discharge Head
in meters
F2670KKK
162
3,9 2,8
PRICE
VITEX CD-CE
163
A1
A2
Free Bore
(mm.)
DE 100/4 OM - TB
760
500
130
100
100
270
60
250
25
450
395
430
14
75
DG 100/4 OM - TB
760
500
130
100
100
270
60
250
25
450
395
430
14
78
MODEL
Mot. Pow.
HP kW
Amp.
3x400 V
n
(rpm)
3x400
6,80
1450
F2681KKK
3x400
8,85
1450
MODEL
l/1'
m3/h
30
60
90
120 150
6,0
4,3
2,4
5,2
3,0
Discharge Head
in meters
VOLTAGE
(V)
CODE
3x690
164
PRICE
VITEX DE-DG
165
PUMPS
DESCRIPTION
B7091KKK
AC 55/2 SB
AD 55/2 SB
B7090KKK
AC 55/2 SP
AD 55/2 SP
B7053KKK
CD 80/2 SB
CE 80/2 SB
B7083KKK
CD 80/4 SB
CE 80/4 SB
B7084KKK
CD 80/4 SP
CE 80/4 SP
B7084KKK
DE 100/2 SB
DE 100/4 SB
DG 100/4 SB
DE 100/4 SP
DG 100/4 SP
B7088KKK
EF 125/4 SB
EM 125/4 SB
EP 125/4 SB
EF 125/4 SP
EM 125/4 SP
EP 125/4 SP
B7091KKK
B7090KKK
AC 55/2 OM-TM
AD 55/2 OM-TM
B7053KKK
B7083KKK
CD 80/4 OM-TB
CE 80/4 OM-TB
B7084KKK
DE 100/4 OM-TB
DG 100/4 OM-TB
CODE
PUMPS
DESCRIPTION
A2-A0114
AC 55/2 SP
AD 55/2 SP
A2-A0100
CD 80/4 SP
CE 80/4 SP
DE 100/4 SP
DG 100/4 SP
A2-A0110
EF 125/4 SP
EM 125/4 SP
EP 125/4 SP
CODE
PUMPS
DESCRIPTION
F2706KKK
AC 50/2 SB
AD 50/2 SB
AC 55/2 SB/SP
AD 55/2 SB/SP
CD 80/4 SB/SP
CE 80/4 SB/SP
F2708KKK
CD 80/2 SB
DE 100/4 SB/SP
DG 100/4 SB/SP
F2710KKK
EF 125/4 SB/SP
EM 125/4 SB/SP
EP 125/4 SB/SP
166
VITEX
PRICE
PRICE
PRICE
50 Hz
PRATIKA
SUBMERSIBLE PUMPS
MULTISTAGE CENTRIFUGAL
SUBMERSIBLE PUMPS FOR CLEAR WATER
The PRATIKA submersible pumps are portable and
ready for use for installation in traditional wells, water
deposits, collection tanks, clear watercourses, lakes
etc.
Design Features
- Stainless steel pump casing
- Suction grid and base in stainless steel
- 15m H07 RN-F power supply cable with plug
- Graphite mechanical seal, ceramic counterface and
NBR 70 rubber lip seal ring
- Oil chamber for seal lubrication
- Stainless steel shaft steel with ceramic facing at the
points of seal wear
- Equipped with 32 mm rubber holder fitting
- Automatic version equipped with float switch
Motor
- Dry motor
- Level of protection IP 68
- Class F insulation
- Single phase supply with capacitor permanently
activated
- Thermal protection built into the motor winding
- Completely insulated cable connection chamber
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
- Suitable for continuous use
50
40
PR
AT
IKA
30
Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 40 C
- Maximum submersion under the water level 10 m
20
10
Applications
- Pumping of water from traditional wells
- Domestic tank installations for boosting domestic
drinking water systems
- Small-scale automatic systems for garden irrigation
- Surface irrigation
Hm
10
0,6
30
1,8
70
4,2
50
3
90
5,4
110
6,6
DNM
L / 1'
m3/ h
Dimensions mm.
Model
CODE
MODEL
Free Bore
DNM
Kg
406
162
178
1,5
1 1/4"
Nominal
Power
Absorbed
Power
HP
kW
HP
kW
L/1'
VOLTAGE
Amp.
F.
N3051010-B
PRATIKA
1,1
0,8
1,6
1,2
1 ~ 230 V
16
N3051000-B
PRATIKA - AUT
1,1
0,8
1,6
1,2
1 ~ 230 V
16
168
20
40
60
80
100
1,2
2,4
3,6
4,8
46
39
31
23
12
46
39
31
23
12
Q
3
m /h
Discharge Head
in meters
PRATIKA
Weight
PRICE
DOMINATOR 4
SUBMERSIBLE PUMPS
4 SUBMERSIBLE MULTISTAGE
CENTRIFUGAL PUMP FOR CLEAN
WATER
Motor
Dry motor with stainless steel casing cooled
by the pumped liquid.
Level of protection IP 68.
Class F insulation.
Single phase supply with capacitor
permanently activated.
Thermal protection built into the motor
winding.
Completely insulated cable connection
chamber.
Self-lubricating ball bearings.
Speed of rotation 2850 rpm.
Suitable for continuous use.
Usage Limitations
Type of liquid: clean water with no suspended
solids or abrasive material.
Maximum liquid temperature 40C.
Maximum submersion under the water level
20 m.
Applications
Pumping of water from traditional wells.
Domestic tank installations for boosting
domestic drinking water systems.
Small-scale automatic systems for garden
irrigation.
Surface irrigation.
60
50
11
75 5/57
/5
6
40
5
50
5/
30
20
10
Hm
L / 1'
m3/ h
10
0,6
20
1,2
30
1,8
40
2,4
60
3,6
50
3,0
70
4,2
90 100
5,4 6,0
80
4,8
Dimensions
Model
Weight
Free Bore
DNM
Kg.
DOMINATOR 4 - 55/50
549
98
2 mm
1 1/4"
8,8
DOMINATOR 4 - 75/56
643
98
2 mm
1 1/4"
9,6
DOMINATOR 4 - 115/57
643
98
2 mm
1 1/4"
9,9
MODEL
Nominal
Power
Absorbed
Power
HP
kW
HP
kW
VOLTAGE
Amp.
F.
Stages
N3200020
DOMINATOR 4 - 55/50 M
0,70
0,50
0,90
0,65
1 ~ 220 240 V
16
N3200010
DOMINATOR 4 - 75/56 M
0,80
0,60
0,75
1 ~ 220 240 V
3,3
16
N3200040
DOMINATOR 4 - 115/57 M
0,80
1,50
1,10
1 ~ 220 240 V
16
169
L/1'
Q
m3/h
Dicharge Head
in meters
CODE
20
40
60
80
1.2
2.4
3.6
4.8
50
38,7
17
56
49,8
38,1
19
57
52
44,4
31,5
16,6
PRICE
DOMINATOR 5
SUBMERSIBLE PUMPS
SUBMERSIBLE MULTISTAGE
CENTRIFUGAL PUMP
FOR CLEAR WATER
The DOMINATOR 5" submersible pumps are
suitable for installation in traditional wells, water
deposits, collection tanks, clear watercourses,
lakes etc.
Design Features
- Impellers and diffusors in AISI 304 stainless
steel
- Stainless steel pump casing
- Suction grid and base in stainless steel
- Graphite mechanical seal, aluminium oxide
counterface
- Oil chamber for seal lubrication
- Shaft in AISI 304 steel with ceramic facing at
the points of wear
- 20 m H07 RN-F power supply cable with plug
- Built in capacitor
- Automatic version equipped with float switch
Motor
- Dry motor with stainless steel casing cooled
by the pumped liquid
- Level of protection IP 68
- Class F insulation
- Single phase supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Completely insulated cable connection
chamber
- Self-lubricating ball bearings
- Speed of rotation 2850 rpm
- Suitable for continuous use
Usage Limitations
- Type of liquid: clean water with no suspended
solids or abrasive material
- Maximum liquid temperature 40 C
- Maximum submersion under the water level
20 m
Applications
- Pumping of water from traditional wells
- Domestic tank installations for boosting
domestic drinking water systems
- Small-scale automatic systems for garden
irrigation
- Surface irrigation
70
60
50
40
/50
75
70/
70
30
40
60
20
140
/65
140
/45
10
Hm
Q
L / 1'
m3/ h
20
2
100
6
80
4
120
160
140
8
Dimensions mm.
Model
A
Weight
Free Bore
DNM
Kg
DOMINATOR 5 - 70/50
470
132
2 mm
1 /4"
13.7
DOMINATOR 5 - 70/75
520
132
2 mm
1 1/4"
15.5
DOMINATOR 5 - 140/45
495
132
2 mm
1 1/4"
14.2
DOMINATOR 5 - 140/65
550
132
2 mm
1 1/4"
15.8
MODEL
N3191000
N3191010
N3191080
D 5 - 70/50
D 5 - 70/50 AUT
D 5 - 70/50
N3191020
N3191030
N3191090
N3191040
N3191050
N3191100
D 5 - 70/75
D 5 - 70/75 AUT
D 5 - 70/75
D 5 - 140/45
D 5 - 140/45 AUT
D 5 - 140/45
D 5 - 140/65
D 5 - 140/65 AUT
D 5 - 140/65
N3191060
N3191070
N3191110
Nominal
Power
Absorbed
Power
L/1'
VOLTAGE
Amp.
F.
N Q
Stages m3/h
HP
kW
HP
kW
0.7
1.3
0.95
1 ~ 220 240 V
3 ~ 400 V
4.5
1.8
16
1.4
1.45
1 ~ 220 240 V
3 ~ 400 V
6.5
2.1
20
1.2
0.9
1.8
1.3
1 ~ 220 240 V
3 ~ 400 V
5.5
2
16
1.5
1.1
2.3
1.7
1 ~ 220 240 V
7.5
20
3 ~ 400 V
2.6
170
20
40
60
80
100
1.2
2.4
3.6
4.8
120 140
PRICE
Discharge Head
in meters
CODE
75
7.2
8.4
7.5
28
21.8 15.2
7.4
38
27.9 18.2
7.6
46
SCM 4 Plus
SUBMERSIBLE PUMPS
4" MULTISTAGE CENTRIFUGAL
SUBMERSIBLE PUMPS COMPLETE
WITH MOTOR
The SCM 4 PLUS submersible pumps consist of a multistage
pumping unit directly connected to a submersible motor.
Especially suitable for pumping from deep 4'' (100mm) wells.
Design Features
- Delivery connection point in microcast AISI 304 stainless steel
- Suction flange in microcast AISI 304 stainless steel
- Pump casing in AISI 304 stainless steel
- Non return valve in AISI 304 stainless steel
- Cable protection filter and trough in AISI 430 stainless steel
- Hexagonal shaft in AISI 303 stainless steel with ceramic facing
on the upper end
- Acetal resin impellers
- Polycarbonate diffusors with ceramic insert at the point of wear
- Polycarbonate diffusor cap with stainless steel insert
- Thrust ring inserted in every stage
- Molybdenum bisulphide polyamide self-lubricating delivery
bearing
Motor
- 4" submersible motor
- Special resin impregnated sealed stator
- Water-cooled thrust bearings and bushes
- Approx. 1.5 m extendible power supply cable
- Non-polluting water cooling
- 4" NEMA flange
- Level of protection IP 58
- Class B insulation
- Speed of rotation 2850 rpm
- Special mechanical seal with sand guard
- Pressure compensation diaphragm
- Supplied without capacitor (single phase version)
- Suitable for continuous use
- Electrical control panel on request
Usage Limitations
- Type of liquid: clean non-aggressive, non-explosive, free of solids
- Maximum liquid temperature 30 C
- Max. start-ups per hour 20
- Motor protection with thermal relay provided by the user
Applications
- Pumping of water from drilled wells
- Automatic systems for garden irrigation
- Surface irrigation for agricultural use
- Drinking water systems
- Pumping and supply of stored deposits or of booster autoclaves
for civil and industrial systems
172
SUBMERSIBLE PUMPS
173
SCM 4 Plus
TABLE FOR CALCULATING PUMP LENGTH
A
Total length
mm.
B
Motor length
mm.
C
Pump length
mm.
576
557
717
688
857
829
1109
1081
1339
1310
242
223
271
242
299
271
327
299
356
327
509
490
628
599
700
672
862
834
1026
997
1317
MODEL
L
Packing length
Total weight
Kg.
334
334
446
446
558
558
782
782
983
983
730
710
870
840
1010
980
1260
1230
1490
1460
11.8
10.8
14.0
12.7
16.1
14.9
19.2
17.9
22.2
20.8
242
223
271
242
299
271
327
299
356
327
356
267
267
357
357
401
401
535
535
670
670
961
660
640
780
750
850
830
1012
990
1180
1150
1470
11.3
10.3
13.1
11.8
14.9
13.7
17.3
16.0
19.8
18.4
22.3
545
526
631
602
744
716
915
887
1058
1029
1372
242
223
271
242
299
271
327
299
356
327
356
303
303
360
360
445
445
588
588
702
702
1016
700
680
780
750
900
870
1070
1040
1200
1180
1520
11.2
10.2
12.9
11.6
14.8
13.6
17.1
15.8
19.4
18.0
21.5
488
469
602
573
687
659
829
801
973
944
1202
1525
242
223
271
242
299
271
327
299
356
327
356
423
246
246
331
331
388
388
502
502
617
617
846
1102
640
620
750
720
840
810
980
950
1120
1100
1350
1680
11.0
10.0
12.8
11.5
14.4
13.2
16.6
15.3
18.8
17.4
20.8
25.0
652
624
790
762
929
900
1142
1466
1816
2407
299
271
327
299
356
327
356
423
590
704
353
353
463
463
573
573
786
1043
1226
1703
800
780
940
910
1080
1050
1300
1620
1970
2560
14.0
12.8
16.1
14.8
18.3
16.9
20.1
24.2
33.1
42.3
951
922
1186
1550
1833
2462
356
327
356
514
590
704
595
595
830
1036
1243
1758
1100
1070
1340
1700
1983
2612
18.0
15.6
18.0
23.9
29.6
42.6
DNM
96
2"
174
105
1 1/4"
DNM
SCM 4 Plus 40
SUBMERSIBLE PUMPS
The power curve refers to the brake horse power (BHP) per stage.
MODEL
N3181000
SCM 4 PLUS-40/57 M
N3181010
SCM 4 PLUS-40/57 T
N3181020
SCM 4 PLUS-40/90 M
N3181030
SCM 4 PLUS-40/90 T
N3181040
SCM 4 PLUS-40/120 M
14
19
N3181050
SCM 4 PLUS-40/120 T
N3181060
SCM 4 PLUS-40/185 M
N3181070
SCM 4 PLUS-40/185 T
N3181080
SCM 4 PLUS-40/240 M
29
38
N3181090
SCM 4 PLUS-40/240 T
Motor
Power
Stadi
Stages
HP
kW
0,5
0,37
0,75
1,5
0,55
L/1'
VOLTAGE
Amp.
1 ~ 230 V
3,2
3 ~ 400 V
1,1
1 ~ 230 V
4,3
3 ~ 400 V
1,6
1 ~ 230 V
5,3
3 ~ 400 V
2,1
1 ~ 230 V
7,8
3 ~ 400 V
3,2
1 ~ 230 V
9,9
3 ~ 400 V
F Q
16
20
30
0,75
40
1,1
1,5
175
m3/h
Discharge Head
in meters
CODE
10
20
30
40
DNM
0,6
1,2
1,8
2,4
49
41
26
76
64
40
104
86
55
158
130
85
10
205
160
110
12
50
11/4"
PRICE
SCM 4 Plus 55
SUBMERSIBLE PUMPS
The power curve refers to the brake horse power (BHP) per stage.
MODEL
Motor
Power
Stadi
Stages
HP
kW
L/1'
VOLTAGE
Amp.
F Q
N3182000
N3182010
SCM 4 PLUS-55/50 M
SCM 4 PLUS-55/50 T
0,5
0,37
1 ~ 230 V
3 ~ 400 V
3,2
1,1
16
N3182020
N3182030
SCM 4 PLUS-55/80 M
SCM 4 PLUS-55/80 T
10
0,75
0,55
1 ~ 230 V
3 ~ 400 V
4,3
1,6
20
N3182040
N3182050
SCM 4 PLUS-55/105 M
SCM 4 PLUS-55/105 T
12
0,75
1 ~ 230 V
3 ~ 400 V
5,3
2,1
30
N3182060
N3182070
SCM 4 PLUS-55/160 M
SCM 4 PLUS-55/160 T
18
1,5
1,1
1 ~ 230 V
3 ~ 400 V
7,8
3,2
40
N3182080
N3182090
SCM 4 PLUS-55/200 M
SCM 4 PLUS-55/200 T
24
1,5
1 ~ 230 V
3 ~ 400 V
9,9
4
50
N3182100
SCM 4 PLUS-55/300 T
37
2,2
3 ~ 400 V
5,9
176
m3/h
Discharge Head
in meters
CODE
10
20
30
40
50
DNM
0,6
1,2
1,8
2,4
47
42
36
23
75
66
55
35
12
98
87
72
46
12
145
132
110
70
24
187
169
145
90
30
278
244
200
140
50
11/4"
PRICE
SCM 4 Plus 75
SUBMERSIBLE PUMPS
The power curve refers to the brake horse power (BHP) per stage.
MODEL
Motor
Power
Stadi
Stages
HP
kW
L/1'
VOLTAGE
Amp.
N3183000
N3183010
SCM 4 PLUS-75/40 M
SCM 4 PLUS-75/40 T
0,5
0,37
1 ~ 230 V
3 ~ 400 V
3,2
1,1
16
N3183020
N3183030
SCM 4 PLUS-75/56 M
SCM 4 PLUS-75/56 T
0,75
0,55
1 ~ 230 V
3 ~ 400 V
4,3
1,6
20
N3183040
N3183050
SCM 4 PLUS-75/75 M
SCM 4 PLUS-75/75 T
11
0,75
1 ~ 230 V
3 ~ 400 V
5,3
2,1
30
N3183060
N3183070
SCM 4 PLUS-75/110 M
SCM 4 PLUS-75/110 T
16
1,5
1,1
1 ~ 230 V
3 ~ 400 V
7,8
3,2
40
N3183080
N3183090
SCM 4 PLUS-75/140 M
SCM 4 PLUS-75/140 T
20
1,5
1 ~ 230 V
3 ~ 400 V
9,9
4
50
N3183100
SCM 4 PLUS-75/210 T
30
2,2
3 ~ 400 V
5,9
177
m3/h
Discharge Head
in meters
CODE
20
30
40
50
60
DNM
1,2
1,8
2,4
3,6
36
33
28
23
15
50
45
40
32
21
67
62
55
45
30
11/4"
100
92
82
68
44
127
116
105
86
57
186
170
155
130
80
PRICE
SUBMERSIBLE PUMPS
The power curve refers to the brake horse power (BHP) per stage.
CODE
MODEL
Motor
Power
Stages
Stadi
VOLTAGE
HP
kW
Amp.
F Q
L/1'
30
40
50
60
80
90
100
m3/h
1,8
2,4
3,6
4,8
5,4
DNM
26
24
22
20
13
6,4
46
43
40
36
23
16
10
58
55
51
46
29
20
11
83
80
74
67
43
30
18 11/4"
109 106
98
88
55
38
21
SCM 4 PLUS-115/30 M
SCM 4 PLUS-115/30 T
0,5
0,37
1 ~ 230 V
3 ~ 400 V
3,2
1,1
16
N3184020
N3184030
SCM 4 PLUS-115/50 M
SCM 4 PLUS-115/50 T
0,75
0,55
1 ~ 230 V
3 ~ 400 V
4,3
1,6
20
N3184040
N3184050
SCM 4 PLUS-115/65 M
SCM 4 PLUS-115/65 T
0,75
1 ~ 230 V
3 ~ 400 V
5,3
2,1
30
N3184060
N3184070
SCM 4 PLUS-115/95 M
SCM 4 PLUS-115/95 T
13
1,5
1,1
1 ~ 230 V
3 ~ 400 V
7,8
3,2
40
N3184080
N3184090
SCM 4 PLUS-115/122 M
SCM 4 PLUS-115/122 T
17
1,5
1 ~ 230 V
3 ~ 400 V
9,9
4
50
N3184100
SCM 4 PLUS-115/185 T
24
2,2
3 ~ 400 V
5,9
85
58
31
N3184110
SCM 4 PLUS-115/245 T
33
3 ~ 400 V
7,8
84
47
178
Discharge Head
in meters
N3184000
N3184010
PRICE
SUBMERSIBLE PUMPS
CODE
MODEL
Motor
Power
Stages
VOLTAGE
HP
kW
Amp.
F Q
N3185000
N3185010
SCM 4 PLUS-150/42 M
SCM 4 PLUS-150/42 T
0,75
1 ~ 230 V
3 ~ 400 V
5,3
2,1
30
N3185020
N3185030
SCM 4 PLUS-150/64 M
SCM 4 PLUS-150/64 T
1,5
1,1
1 ~ 230 V
3 ~ 400 V
7,8
3,2
40
N3185040
N3185050
SCM 4 PLUS-150/84 M
SCM 4 PLUS-150/84 T
12
1,5
1 ~ 230 V
3 ~ 400 V
9,9
4
50
N3185060
SCM 4 PLUS-150/120 T
17
2,2
3 ~ 400 V
5,9
N3185070
SCM 4 PLUS-150/170 T
24
3 ~ 400 V
7,8
N3185080
SCM 4 PLUS-150/200 T
29
5,5
3 ~ 400 V
10
N3185090
SCM 4 PLUS-150/300 T
42
7,5
5,5
3 ~ 400 V
13,7
179
L/1'
40
50
60
80
m3/h
2,4
3,6
4,8
7,2
8,4 DNM
38
37
36
33
26
17
10
59
58
57
50
39
27
15
80
78
75
64
50
34
20
96
77
53
26
69
30
71
32
82
Discharge Head
in meters
The power curve refers to the brake horse power (BHP) per stage.
2"
PRICE
SUBMERSIBLE PUMPS
The power curve refers to the brake horse power (BHP) per stage.
MODEL
Motor
Power
Stadi
Stages
L/1'
VOLTAGE
HP
kW
1,5
N3186000
SCM 4 PLUS-250/53 M
N3186010
SCM 4 PLUS-250/53 T
N3186020
SCM 4 PLUS-250/78 T
13
N3186030
SCM 4 PLUS-250/100 T
17
N3186040
SCM 4 PLUS-250/127 T
N3186050
SCM 4 PLUS-250/185 T
Amp.
1 ~ 230 V
9,9
3 ~ 400 V
2,2
3 ~ 400 V
5,9
3 ~ 400 V
7,8
21
5,5
3 ~ 400 V
10
31
7,5
5,5
3 ~ 400 V
13,7
180
F Q
m3/h
50
Discharge Head
in meters
CODE
7,2
43
41
37
26
18
11
63
59
54
41
30
18
83
78
66
54
41
24
106 100
90
68
49
31
14
81
57
36
18
2"
PRICE
SCM 4 Plus
SUBMERSIBLE PUMPS
PUMP-ENDS
10
20
30
40
NECESSARY
MOTOR
49
41
37
26
HP 0,5
N1050020
76
64
40
HP 0,75
N1050030
104
86
55
HP 1
N1050040
85
10
HP 1,5
N1050050
12
HP 2
CODE
MODEL
10
20
30
40
50
NECESSARY
MOTOR
N1050060
47
42
36
23
HP 0,5
N1050070
75
66
55
35
12
HP 0,75
N1050080
98
87
72
46
15
HP 1
N1050090
70
24
HP 1,5
N1050100
90
30
HP 2
N1050110
50
HP 3
CODE
MODEL
20
30
40
50
60
NECESSARY
MOTOR
N1050120
36
33
28
23
15
HP 0,5
N1050130
50
45
40
32
21
HP 0,75
N1050140
67
62
55
45
30
HP 1
N1050150
100
92
82
68
44
HP 1,5
N1050160
86
57
HP 2
N1050170
80
HP 3
N1050010
Ql/1'
Ql/1'
MODEL
Ql/1'
181
CODE
158 130
PRICE
PRICE
PRICE
SCM 4 Plus
PUMP-ENDS
30
40
50
60
80
90
100
NECESSARY
MOTOR
26
24
22
20
13
6,4
HP 0,5
N1050190
46
43
40
36
23
16
10
HP 0,75
N1050200
58
55
51
46
29
20
11
HP 1
N1050210
83
80
74
67
43
30
18
HP 1,5
N1050220
98
88
55
38
21
HP 2
N1050230
85
58
31
HP 3
N1050240
84
47
HP 4
MODEL
N1050180
CODE
MODEL
N1050250
Ql/1'
CODE
Ql/1'
109 106
NECESSARY
MOTOR
50
60
38
37
36
33
26
17
10
HP 1
N1050260
59
58
57
50
39
27
15
HP 1,5
N1050270
80
78
75
64
50
34
20
HP 2
N1050280
96
77
53
26
HP 3
N1050290
69
30
HP 4
N1050300
71
32
HP 5,5
N1050310
82
HP 7,5
40
NECESSARY
MOTOR
CODE
MODEL
N1050320
43
41
37
26
18
11
HP 2
N1050330
63
59
54
41
30
18
HP 3
N1050340
83
78
66
54
41
24
HP 4
N1050350
90
68
49
31
14
HP 5,5
N1050360
81
57
36
18
HP 7,5
182
106 100
PRICE
PRICE
PRICE
SUBMERSIBLE PUMPS
4 SUBMERSIBLE MOTORS FOR SCM 4 PLUS
NEMA SPEC WITH PART ELECTRICAL CABLE
POWER
HP
kW
VOLTAGE
Hz
222P0390
0,5
0,37
1 ~ 230V
50
221P0740
0,5
0,37
3 ~ 400V
50
222P0400
0,75
0,55
1 ~ 230V
50
221P0740
0,75
0,55
3 ~ 400V
50
222P0310
0,74
1 ~ 230V
50
221P0760
0,74
3 ~ 400V
50
222P0320
1,5
1,1
1 ~ 230V
50
221P0770
1,5
1,1
3 ~ 400V
50
222P0330
1,5
1 ~ 230V
50
221P0570
1,5
3 ~ 400V
50
221P0580
2,2
3 ~ 400V
50
221P0590
3 ~ 400V
50
221P0600
5,5
3 ~ 400V
50
221P0610
7,5
5,5
3 ~ 400V
50
POWER
HP
kW
VOLTAGE
Hz
222P0010
0,5
0,37
1 ~ 230V
50
221P0030
0,5
0,37
3 ~ 400V
50
222P0020
0,75
0,55
1 ~ 230V
50
221P0040
0,75
0,55
3 ~ 400V
50
222P0030
0,74
1 ~ 230V
50
221P0050
0,74
3 ~ 400V
50
222P0040
1,5
1,1
1 ~ 230V
50
221P0060
1,5
1,1
3 ~ 400V
50
222P0050
1,5
1 ~ 230V
50
221P0070
1,5
3 ~ 400V
50
221P0080
2,2
3 ~ 400V
50
221P0090
3 ~ 400V
50
221P0100
5,5
3 ~ 400V
50
CODE
PRICE
WATER COOLED
CODE
OIL COOLED
183
PRICE
SA
SUBMERSIBLE PUMPS
6" MULTISTAGE SUBMERSIBLE PUMPS
COMPLETE WITH MOTOR
The SA submerged pumps consist of a multistage pumping unit
directly connected to a submersible motor. Especially suitable for
pumping from deep 6'' (150mm) wells.
Design Features
- Delivery connection point in nodular cast iron
- Suction flange in nodular cast iron
- Stainless steel outer liner
- Built in non return valve
- Cable protection filter and trough, in stainless steel
- Stainless steel splined shaft
- Noryl or polycarbonate impellers:
SA 615/SA 625 with radial impellers,
SA630/SA 650 with semiaxial impellers
- Noryl diffusors
- Stainless steel wear rings
- Bronze/rubber bush bearings
Motor
- 6" Franklin submersible motor
- Special resin impregnated sealed stator
- Water-cooled thrust bearings and bushes
- Approx. 1.5 m extendible power supply cable
- Non-polluting water cooling
- 6" NEMA flange
- Level of protection IP58. Class F insulation
- Speed of rotation 2850 rpm
- Special mechanical seal with sand guard
- Pressure compensation diaphragm
- Suitable for continuous use
- Electrical control panel on request
- Direction of rotation anticlockwise (seen from the delivery end)
Usage Limitations
- Type of liquid: clean non-aggressive, non-explosive, free of solids
- Maximum liquid temperature 30 C
- Max. start-ups per hour: 15
- Motor protection with thermal relay provided by the user
- Maximum quantity of sand present: 40 g/m3
Applications
- Civil and industrial supply systems
- Overhead or surface irrigation
- Boosting
- Firefighting
- Various civil and industrial applications
- Mains water supply systems
184
SA 615
SUBMERSIBLE PUMPS
145
L1
DNM 3 Gas
MOTOR
Model
Electric pump
Pump
casing Motor
L1
L
Weight
SA 615/4
SA 615/5
SA 615/6
SA 615/9
SA 615/12
SA 615/18
(mm)
(mm)
(mm)
(kg)
435
478
511
625
738
966
87
87
87
87
137
137
791
901
1056
1329
1384
1677
22
27
30
41
58
67
The power curve refers to the brake horse power (BHP) per stage.
CODE
MODEL
N of
Stages
Motor
Power
VOLTAGE
HP
kW
Amp.
L/1'
120
160
200
230
260
300
m3/h
7,2
9,6
12
13,8
15,6
18
PRICE
SA 615/4*
2,2
3 ~ 400 V
5,5
62
60
55
51
46
39
31
D8761KKK
SA 615/5*
3 ~ 400 V
78
74
69
63
57
49
39
D8762KKK
SA 615/6*
4,0
3 ~ 400 V
10
94
89
82
75
68
58
46
D8763KKK
SA 615/9*
7,5
5,5
3 ~ 400 V
13
140
134
123
113
101
88
70
D8764KKK
SA 615/12
12
10
7,5
3 ~ 400 V
16
187
179
166
152
136
118
92
D8765KKK
SA 615/18
18
15
11
3 ~ 400 V
23
281
268
250
231
210
180
138
* WITH 4 MOTOR
185
Discharge Head
in meters
D8760KKK
SA 625
SUBMERSIBLE PUMPS
145
L1
DNM 3 Gas
MOTOR
Model
SA 625/4
SA 625/6
SA 625/8
SA 625/12
SA 625/16
SA 625/20
Electric pump
Pump
casing Motor
L1
L
Weight
(mm)
(mm)
(mm)
(kg)
511
625
738
966
1193
1474
87
87
137
137
137
137
1056
1329
1384
1677
1969
2316
30
41
57
66
75
86
The power curve refers to the brake horse power (BHP) per stage.
CODE
MODEL
N of
Stages
Motor
Power
VOLTAGE
HP
kW
Amp.
L/1'
200
300
350
400
500
600
m3/h
12
18
21
24
30
36
PRICE
SA 625/4*
3 ~ 400 V
10
61
53
48
44
40
28
17
D8772KKK
SA 625/6*
7,5
5,5
3 ~ 400 V
12
91
80
71
66
59
43
25
D8773KKK
SA 625/8
10
7,5
3 ~ 400 V
16
122
106
95
87
79
58
34
D8774KKK
SA 625/12
12
15
11
3 ~ 400 V
23
182
159
143
131
119
88
50
D8775KKK
SA 625/16
16
20
15
3 ~ 400 V
31
243
212
190
177
159
118
67
D8776KKK
SA 625/20
20
25
18,5
3 ~ 400 V
38
304
265
238
220
198
146
84
* WITH 4 MOTOR
186
Discharge Head
in meters
D8771KKK
SA 630
SUBMERSIBLE PUMPS
145
L1
DNM 3 Gas
MOTOR
Model
SA 630/4
SA 630/5
SA 630/8
SA 630/10
SA 630/12
Electric pump
Pump
casing Motor
L1
L
Weight
(mm)
(mm)
(mm)
(kg)
522
582
762
882
1002
87
137
137
137
137
1226
1228
1473
1658
1844
39
54
62
70
78
The power curve refers to the brake horse power (BHP) per stage.
CODE
MODEL
N of
Stages
Motor
Power
HP
kW
VOLTAGE
Amp.
L/1'
300
400
500
600
700
800
m3/h
18
24
30
36
42
48
PRICE
SA 630/4*
7,5
5,5
3 ~ 400 V
12
63
57
53
47
40
30
19
D8783KKK
SA 630/5
10
7,5
3 ~ 400 V
16
78
72
67
59
50
37
23
D8784KKK
SA 630/8
15
11
3 ~ 400 V
23
126
114
106
94
80
62
37
D8785KKK
SA 630/10
10
20
15
3 ~ 400 V
31
157
143
133
119
101
76
45
D8786KKK
SA 630/12
12
25
18,5
3 ~ 400 V
38
188
171
160
143
122
92
55
* WITH 4 MOTOR
187
Discharge Head
in meters
D8782KKK
SA 650
SUBMERSIBLE PUMPS
145
L1
DNM 3 Gas
MOTOR
Model
SA 650/4
SA 650/6
SA 650/9
SA 650/10
SA 650/12
Electric pump
Pump
casing Motor
L1
L
Weight
(mm)
(mm)
(mm)
(kg)
522
642
822
882
1002
137
137
137
137
137
1168
1353
1598
1724
1909
53
61
69
76
84
The power curve refers to the brake horse power (BHP) per stage.
CODE
MODEL
N of
Stages
Motor
Power
HP
kW
VOLTAGE
Amp.
L/1'
600
700
800
900
1000
1100
m3/h
36
42
48
54
60
66
PRICE
SA 650/4
10
7,5
3 ~ 400 V
15
54
40
35
31
25
19
13
D8793KKK
SA 650/6
15
11
3 ~ 400 V
21
81
59
53
46
37
29
20
D8794KKK
SA 650/9
20
15
3 ~ 400 V
31
122
90
80
68
57
44
30
D8795KKK
SA 650/10
10
25
18,5
3 ~ 400 V
34
135
101
90
77
63
49
33
D8796KKK
SA 650/12
12
30
22
3 ~ 400 V
40
162
120
107
93
75
59
40
* WITH 4 MOTOR
188
Discharge Head
in meters
D8792KKK
SCM 4 Plus - SA 6
ACCESSORIES
Direct Starting
1 ~ 220 240 V - 50 Hz
3 ~ 400 V - 50 Hz
1 four-pole cable
4 x mm2
MOTOR
1 four-pole cable
4 x mm2
MOTOR
1.5 2.5 4
10
1.5 2.5 4
kW
Cables - L max in m.
kW
0.37
0.37
777
0.55
0.55
523
0.75
0.75
384
1.1
1.1
262
1.5
47 75 113 188
1.5
192 320
2.2
32 51 77 128
2.2
35 50 70
Cables - L max in m.
5.5
10 16 25
52
7.5
9.2
52
84
11
70
13
60
90
78
15
18.5
22
189
50 Hz
P.G.A.
PGA
DELTA OIL
SPECIAL SELF-PRIMING LIQUID RING PUMPS
FOR DIESEL TRANSFER
The PGA series pumps are particularly
suitable for diesel transfer.
30
10
O
IL
4 M DELIVERY KIT
PIPE AND GUN
0
-4
TA
EL
/D
20
Hm
Q
4 M SUCTION KIT
60
0
Applications
- Manufacture of delivery assemblies
Usage Limitations
- Type of liquid: diesel
- Maximum liquid temperature 50C
- Maximum recommended suction height
5m with foot valve
- Maximum operating pressure 6 bar
40
-3
- DELTA-OIL version
Handle, electric switch, power supply cable
with plug
Motor
- Enclosed, externally ventilated
- Level of protection IP55
- Class F insulation
- Single phase power supply with capacitor
permanently activated and thermal
protection built into the motor winding
- Three phase power supply with external
protection provided by the user
- Speed of rotation 2850 rpm
- Suitable for continuous use
40
Design Features
- Cast iron pump casing
- Cast iron motor bracket
- Brass finned impeller
- Stainless steel shaft
- Mechanical graphite seal with ceramic
counterface
- Intermediate flange drainage pipe
50
L / 1'
m3/ h
15
0,9
30
1,8
45
2,7
75
4,5
VOLUMETRIC
LITRE-COUNTER
Dimensions mm.
Model
A
60
3,6
Weight
E
DNA
DNM
kg
141
255
20
120
119
3/4"
3/4"
6,2
PGA 60 - 40
148
260
24
120
123
1"
1"
DELTA OIL
141
255
20
120
119
3/4"
3/4"
CODE
MODEL
Nominal Absorbed
Power
Power
VOLTAGE
Amp.
F. Q
HP kW HP kW
N6232090
N6232100
PGA 40 - 30 M
PGA 40 - 30 T
1 ~ 220 240 V
3 ~ 230 400 V
2,7
1,6-0,9
N6232130
N6232140
PGA 60 - 40 M
PGA 60 - 40 T
1 ~ 220 240 V
3 ~ 230 400 V
4,5
2,7-1,6
12,5
N6232170
DELTA OIL
1 ~ 220 240 V
2,7
ACCESSORIES
ZA000840
4 M SUCTION KIT
ZA005380
ZA000120
ZA005160
ZA000130
191
L/1'
10
15
25
35
45
60
m3/h
0,3
0,6
0,9
1,5
2,1
2,7
3,6
Discharge Head
in meters
PGA 40 - 30
28
23
18
13
39
34
32
25
18
12
28
23
18
13
PRICE
Model
Weight
Free Clearance
DNM
Kg
VERSAILLES 80/7
144
231
403
1,5
1 1/4"
6,7
VERSAILLES 160/8
144
231
425
1,5
1 1/4"
VERSAILLES 250/10
285
372
620
1,5
1 /4"
7,8
VERSAILLES 350/12
285
372
620
1,5
1 1/4"
9,3
MODEL
Nominal
Power
HP
Absorbed
Power
kW
HP
VOLTAGE
Amp.
F.
Ql/1'
N2121000
VERSAILLES 80/7
0,3
0,2
0,4
0,3
1 ~ 220 240 V
1,3
6,3
N2121010
VERSAILLES 160/8
0,5
0,37
0,6
2,2
N2121020
0,55
1,2
0,9
1 ~ 220 240 V
4,5
10
N2121030
VERSAILLES 350/12
1,1
0,8
1,6
1,2
1 ~ 220 240 V
5,1
16
ZB401690
VULCANO
ZB401700
GAISER
ZB401710
CAMPANA
ZB401720
ZB401730
192
kW
Discharge Head
in meters
CODE
GAISER
CAMPANA
150 - H 230
15 - H 45
80 - H 45
180 - H 360
20 - H 110
90 - H 45
230 - H 500
30 - H 180
95 - H 45
300 - H 600
50 - H 250
100 - H 45
PRICE
VERSAILLES
VULCANO
GAISER
CAMPANA
193
PRESSURE ASSEMBLIES
50 Hz
PRESSURE ASSEMBLIES
SIZING HOME WATER SYSTEMS
The fundamental data for selecting a pressure assemblie unit is:
a)
the water flow rate required at the moment of maximum usage
b)
the total delivery head
The flow rate required may be taken from the average statistical values diagram shown below (Fig. No. 1).
The calculation of the total delivery head (which corresponds to the minimum unit working pressure) provides for three different cases:
A)
supply from a deposit at the same level as the unit
B)
supply from a mains water supply system or deposit higher than the unit
C)
supply from a well or deposit situated lower than the unit
Case A) The height of the highest sampling point is added to the pressure value required at that point plus any flow resistance. (See
example Fig. No. 2)
Case B) Proceed as per case A, then take from the figure obtained the actual pressure value of the water supply system or the pressure
value developed as a result of the drop from the deposit. (See example Fig. No. 3)
Case C) Proceed as per case A, then add to the figure obtained the value in metres between the water level and the unit. (see Fig. No.
4)
The figures obtained compared with the tables specifying the features of the different autoclave units shown in the catalogue will allow
the most suitable unit to be selected. You must consider that in these tables the highest minimum tap pressure provided for is 1.5 atm.
The information outlined is of a general nature as the different specific conditions of use cannot be taken into consideration.
Fig. 1
FLATS (2 wcS)
50
40
60
30
IC
TE
ES
M
18
200
65
150
70
100
75
63
20
60
ES
57
ST
300
NS
50
IO
60
UT
43
50
IT
80
LS
30
ST
100
TE
20
500
IN
200
O
F
PA F
R
17
NUMBER OF PEOPLE
16
14
66
12
10
5
7 8 9 10
12 14 16
18 20
30
40
60 80 100
m3/h
% CALCULATED CONTEMPORANEOUSNESS % CALCULATED CONTEMPORANEOUSNESS
195
80
PRESSURE ASSEMBLIES
Fig. 2
HE
CASE A
H building
Minimum pressure
Flow resistance
Deposit
18 +
15 +
2=
Meters
35
HE = Building height 18 m.
Fig. 3
Deposit
HD
CASE B
Head necessary
Mains water supply pressure
35 20 =
Meters
15
Pressure necessary
The tank
Public water
supply system
pressure 2 ATM
35 20 =
Meters
15
HD = Deposit height 20 m.
Fig. 4
CASO C
Head necessary
Suction Height
35 +
5=
HA
Meters
HA = Suction height 5 m.
196
40
PRESSURE ASSEMBLIES
FLOW RESISTANCE AND WATER SPEED TABLE
GALVANISED PIPES - NEW
FLOW RATE
lt./sec.
0,6
10
0,16
0,855
0,470
0,292
9,910
2,407
0,784
0,9
15
0,25
1,282
0,705
0,438
0,249
20,11
4,862
1,570
0,416
1,2
20
0,33
1,710
0,940
0,584
0,331
0,249
33,53
8,035
2,588
0,677
0,346
2,138
1,174
0,730
0,415
0,312
49,93
11,91
3,834
1,004
0,510
2,565
1,409
0,876
0,498
0,374
0,231
16,50
5,277
1,379
0,700
0,223
25
0,42
1"
27,00
11/2"
41,25
lt./min.
1,5
/4"
21,25
11/4"
35,75
m3/h
/2"
15,75
2"
52,50
21/2"
68,00
3"
80,25
31/2"
92,50
4"
105,0
5"
130,0
6"
155,5
1,8
30
0,50
69,34
2,1
35
0,58
2,993
1,644
1,022
0,581
0,436
0,269
91,54
21,75
6,949
1,811
0,914
0,291
2,4
40
0,67
1,879
1,168
0,664
0,499
0,308
27,66
8,820
2,290
1,1160
0,368
3,0
50
0,83
2,349
1,460
0,830
0,623
0,385
0,229
41,40
13,14
3,403
1,719
0,544
0,159
3,6
60
1,00
2,819
1,751
0,996
0,748
0,462
0,275
57,74
18,28
4,718
2,375
0,751
0,218
4,2
70
1,12
3,288
2,043
1,162
0,873
0,539
0,321
0,231
76,49
24,18
6,231
3,132
0,988
0,287
0,131
4,8
80
1,33
2,335
1,328
0,997
0,616
0,376
0,263
30,87
7,940
3,988
1,254
0,363
0,164
5,4
90
1,50
2,627
1,494
1,122
0,693
0,413
0,296
38,30
9,828
4,927
1,551
0,449
0,203
6,0
100
1,67
2,919
1,660
1,247
0,770
0,459
0,329
0,248
46,49
11,90
5,972
1,875
0,542
0,244
0,124
7,5
125
2,08
3,649
2,075
1,558
0,962
0,574
0,412
0,310
0,241
70,41
17,93
8,967
2,802
0,809
0,365
0,185
0,101
9,0
150
2,50
2,490
1,870
1,154
0,688
0,494
0,372
0,289
25,11
12,53
3,903
1,124
0,506
0,256
0,140
10,5
175
2,92
2,904
2,182
1,347
0,803
0,576
0,434
0,337
33,32
16,66
5,179
1,488
0,670
0,338
0,184
12
200
3,33
3,319
2,493
1,539
0,918
0,659
0,496
0,385
0,251
42,75
21,36
6,624
1,901
0,855
0,431
0,234
0,084
15
250
4,17
4,149
3,117
1,924
1,147
0,823
0,620
0,481
0,314
64,86
32,32
10,03
2,860
1,282
0,646
0,350
0,126
18
300
5,00
3,740
2,309
1,377
0,988
0,744
0,577
0,377
0,263
45,52
14,04
4,009
1,792
0,903
0,488
0,175
0,074
24
400
6,67
4,987
3,078
1,836
1,317
0,992
0,770
0,502
0,351
78,17
24,04
6,828
3,053
1,530
0,829
0,294
0,124
30
500
8,33
3,848
2,295
1,647
1,240
0,962
0,628
0,439
36,71
10,40
4,622
2,315
1,254
0,445
0,187
36
600
10,0
4,618
2,753
1,976
1,488
1,155
0,753
0,526
51,84
14,62
6,505
3,261
1,757
0,623
0,260
42
700
11,7
3,212
2,306
1,736
1,347
0,879
0,614
19,52
8,693
4,356
2,345
0,831
0,347
48
800
13,3
3,671
2,635
1,984
1,540
1,005
0,702
25,20
11,18
5,582
3,009
1,066
0,445
54
900
15,0
4,130
2,964
2,232
1,732
1,130
0,790
31,51
13,97
6,983
3,762
1,328
0,555
60
1000
16,7
4,589
3,294
2,480
1,925
1,256
0,877
38,43
17,06
8,521
4,595
1,616
0,674
75
1250
20,8
4,117
3,100
2,406
1,5701,883
1,097
26,10
13,00
7,010
2,458
1,027
90
1500
25,0
4,941
3,720
2,887
2,197
1,316
36,97
18,42
9,892
3,458
1,444
105
1750
29,2
4,340
3,368
2,511
1,535
24,76
13,30
4,665
1,934
120
2000
33,3
4,960
3,850
3,139
1,754
31,94
17,16
5,995
2,496
150
2500
41,7
180
3000
50,0
5,023
2,632
13,05
5,417
240
4000
66,7
22,72
8,926
300
5000
83,3
4,812
3,767
2,193
26,26
9,216
3,807
3,509
4,386
14,42
N.B. - To evaluate the flow resistance in pipes made of different materials, the value found for the galvanised pipe must be
multiplied by the following set coefficients:
0,6 for PVC pipes
0,7 for aluminium pipes
0,8 for rolled steel pipes
1,3 for cement fibre pipes
197
48
Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use
40
32
16
8
Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation
Hm
Q
WATERPRESS 60/50
WATERPRESS 60/50
30
1,8
20
1,2
10
0,6
50
3
40
2,4
Weight
DNA
DNM
kg
510
430
470
260
1" F
1" F
14,5
Nominal
Power
HP
N5209160
L / 1'
m3/ h
Dimensions mm.
Model
MODEL
60/5
24
Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height 8m with foot valve
- Maximum operating pressure 6 bar
CODE
WP
kW
Absorbed
Power
HP
10
40
50
m /h
Discharge
Head
in meters
46
36
L/1'
VOLTAGE
Amp.
F.
kW
198
10
20
30
PRICE
Q
3
31
24
WATERPRESS
WATERPRESS 70/50
The WATERPRESS 70/50 is a booster set produced
with JET self-priming centrifugal pump.
The WATERPRESS 70/50 is supplied wired, tested
and with expansion tank.
Design Features
- Cast iron pump casing
- Cast iron motor bracket
- Technopolymer impeller, Venturi tube and nozzle
- Technopolymer diffusor, with stainless steel shim
ring
- Stainless steel shaft
- Graphite mechanical seal with ceramic counterface
- Pressure switch (max 6 bar) calibrated at:
min. 2 - max. 3 bar
- Pressure gauge
- Pressed brass 3 way fitting
- 24 Lt steel expansion tank with interchangeable
food-quality rubber diaphragm
- Flexible pipe for water connection
- 1.5 m H05 RN-F power supply cable with plug
Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use
50
7 0/5
10
Hm
Q
L / 1'
m3/ h
30
1,8
20
1,2
10
0,6
50
3
40
2,4
60
3,6
WATERPRESS 70/50
1,36
DNA
DNM
kg
520
460
550
315
1" F
1" F
22,3
kW
Weight
Nominal
Power
HP
80
4,8
70
4,2
Dimensions mm.
Model
SS
20
Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation
MODEL
PRE
30
Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height 8m with foot valve
- Maximum operating pressure 6 bar
CODE
WA
TE R
40
Absorbed
Power
HP
1,5
VOLTAGE
Amp.
F.
kW
199
16
20
30
70
L/1'
10
40
50
60
m3/h
3,6 4,2
Discharge
Head
in meters
50
PRICE
46
41
37
32
28
18
60
50
Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use
40
WP
30
X7
0/
20
Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height 8m with foot valve
- Maximum operating pressure 6 bar
Hm
Q
50
40
2,4
60
3,6
Weight
DNA
DNM
kg
520
445
565
260
1" F
1" F
13,8
Nominal
Power
HP
80
4,8
70
4,2
Dimensions mm.
30
1,8
20
1,2
10
0,6
L / 1'
m3/ h
Model
MODEL
50
10
Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation
CODE
INO
Absorbed
Power
kW
HP
0,95 0,7
1,36
Amp.
F.
kW
4,5
200
16
20
30
70
10
40
50
60
m /h
3,6 4,2
Discharge
Head
in meters
48
L/1'
VOLTAGE
PRICE
Q
3
42 37,5 31
25
16
WATERPRESS INOX
WATERPRESS INOX 80/48
The WATERPRESS INOX 80/48 is a booster set
produced with MAX self-priming multistage centrifugal
pump. The WATERPRESS INOX 80/48 is supplied
wired, tested and complete with steel expansion tank.
Design Features
- AISI 304 stainless steel pump casing
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel shim
ring
- Technopolymer diffusors
- AISI 304 stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic counterface
- Pressure switch (max 6 bar) calibrated at:
min. 2 - max. 3 bar
- Pressure gauge
- Chromium plated pressed brass 5 way fitting
- 24 Lt steel expansion tank with interchangeable
food-quality rubber diaphragm
- Flexible pipe for water connection
- 1.5 m H05 RN-F power supply cable with plug
60
Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use
50
40
WP
30
Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height recommended 7 m with
foot valve
- Maximum operating pressure 7 bar
Hm
Q
L / 1'
m3/ h
10
20
30
40
50
60
70
80
0,6
1,2
1,8
2,4
3,6
4,2
4,8
Weight
DNA
DNM
kg
520
430
550
260
1" F
1" F
12,3
Nominal
Power
HP
Dimensions mm.
N5301110
0 /4
10
Model
MODEL
X8
20
Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation
CODE
INO
Absorbed
Power
kW
HP
0,75 0,55
1,1
VOLTAGE
Amp.
F.
kW
4,0
201
12,5
20
30
70
L/1'
10
40
50
60
m3/h
3,6 4,2
Discharge
Head
in meters
45
PRICE
41
36
32
28
22
17
10
60
Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use
50
40
30
Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height recommended 7 m with
foot valve
- Maximum operating pressure 7 bar
MODEL
0 /4
Hm
Q
L / 1'
m3/ h
10
20
30
40
50
60
70
80
0,6
1,2
1,8
2,4
3,6
4,2
4,8
Dimensions mm.
Weight
DNA
DNM
kg
640
520
640
370
1" F
1" F
18
Nominal
Power
HP
N5301140
X8
10
Model
CODE
INO
20
Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation
WP
Absorbed
Power
kW
HP
1,1
VOLTAGE
Amp.
F.
kW
202
4,0
12,5
20
30
70
L/1'
10
40
50
60
m3/h
3,6 4,2
Discharge
Head
in meters
45
PRICE
41
36
32
28
22
17
10
WATERPRESS INOX 50 L
WATERPRESS INOX 120/60 50 L
The WATERPRESS INOX 120/60 50 L is a booster
set produced with MAX self-priming multistage
centrifugal pump.
The WATERPRESS INOX 120/60 50 L is supplied
wired, tested and complete with 50 Lt steel expansion
tank.
Design Features
- AISI 304 stainless steel pump casing
- Die-cast aluminium motor bracket
- Technopolymer impellers with stainless steel shim
ring
- Technopolymer diffusors
- AISI 304 stainless steel shaft (hydraulic end)
- Graphite mechanical seal with ceramic counterface
- Pressure switch: electronic control and protection
device AQUA TROL (adjustable starting pressure
from 1,5 to 3 bar)
- Pressure gauge
- Chromium plated pressed brass 5 way fitting
- 50 Lt steel expansion tank with interchangeable
food-quality rubber diaphragm
- Flexible pipe for water connection
- 1.5 m H05 RN-F power supply cable with plug
60
Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use
50
40
10
Hm
Q
N5301130
20
1,2
L / 1'
m3/ h
60
3,6
40
2,4
100
6
80
4,8
Dimensions mm.
Model
MODEL
12
0/6
0
20
Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation
CODE
IN
OX
30
Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height recommended 7 m with
foot valve
- Maximum operating pressure 7 bar
WA
TE
RP
RE
SS
120
7,2
Weight
DNA
DNM
kg
640
520
640
370
1" F
1" F
21
Nominal
Power
Absorbed
Power
HP
kW
HP
0,9
1,7
VOLTAGE
Amp.
F.
kW
203
5,8
20
L/1'
20
40
60
80
m3/h
1,2
2,4
3,6
4,8
Discharge
Head
in meters
60
55
48
36
26
PRICE
WATERPRESS SUPERINOX
WATERPRESS SUPERINOX
The WATERPRESS SUPERINOX is a booster set
produced with JETINOX self-priming centrifugal pump.
The WATERPRESS SUPERINOX is supplied wired,
tested and complete with stainless steel expansion
tank.
Design Features
- Pump casing in AISI 304 stainless steel
- Die-cast aluminium motor bracket
- Technopolymer impeller with stainless steel shim
ring
- Monobloc technopolymer diffusor-Venturi-nozzle
assembly
- Stainless steel shaft
- Graphite mechanical seal with ceramic counterface
- Technopolymer seal holder plate
- Pressure switch (max 6 bar) calibrated at:
min. 2 - max. 3 bar
- Pressure gauge
- Chromium plated pressed brass 5 way fitting
- Stainless steel expansion tank with interchangeable
food-quality rubber diaphragm
- Flexible pipe for water connection
- 1.5 m H05 RN-F power supply cable with plug
48
40
32
Motor
- Enclosed, externally ventilated
- Level of protection IP44
- Class F insulation
- Single phase power supply with capacitor
permanently activated
- Thermal protection built into the motor winding
- Speed of rotation 2850 rpm
- Suitable for continuous use
24
60/
50
16
8
Usage Limitations
- Type of liquid: clean water with no suspended solids
or abrasive material
- Maximum liquid temperature 50 C
- Maximum suction height 8m with foot valve
- Maximum operating pressure 6 bar
Hm
Q
L / 1'
m3/ h
10
0,6
30
1,8
20
1,2
50
3
40
2,4
60
3,6
80
4,8
70
4,2
Applications
- Pumping and distribution of water in domestic
systems
- Booster systems
- Washing systems and irrigation
Dimensions mm.
Model
WATERPRESSSUPERINOX 60/50
CODE
MODEL
Weight
530
425
550
280
Nominal
Power
Absorbed
Power
HP
kW
HP
kW
0,55
1,1
0,8
VOLTAGE
Amp.
1 ~ 220 240 V
204
F.
12,5
DNA
1" F
L/1'
DNM
kg
1" F
11,2
10
20
30
40
50
60
80
m /h
0,6
1,2
1,8
2,4
3,6
4,8
Discharge
Head
in meters
46
36
31
26
18
Q
3
PRICE
50 Hz
ACCESSORIES
HYDRAULIC ACCESSORIES
CODE
MODEL
DESCRIPTION
ZA004520
KA4
SUCTION KIT 4 m
ZA003830
KA7
SUCTION KIT 7 m
ZA004080
NIPPLEX 1 M-M
ZA000900
RCF 30
1 1/4
ZA000910
RCF 40
ZA000920
RCF 50
ZA000270
TF 500
1 x mm 500 M-F
FLEXIBLE PIPE
ZA003060
TF 600
1 x mm 600 M-F
FLEXIBLE PIPE
ZA003160
TF 700
1 x mm 700 M-F
FLEXIBLE PIPE
ZA003070
TF 800
1 x mm 800 M-F
FLEXIBLE PIPE
ZA007430
GA 1 1/4
ZA007440
GA 2
2 x mm 500 M-F
ZA007450
GA 2 1/2
ZA007460
GA 3
3 x mm 500 M-F
ZA002030
MAR 6
ZA005170
MAP 6
ZA000680
MAR 10
ZA000780
MAP 10
207
1/2
FLEXIBLE PIPE
FLEXIBLE PIPE
PRICE
ACCESSORIES
HYDRAULIC ACCESSORIES
CODE
MODEL
DESCRIPTION
N2054010
PAF
ZA008450
PAA
ZB401770
B1
B2
ZA000240
R3V
ZA000260
R5V
ZA000020
ZA003000
ZA003190
ZA003200
ZA003210
ZA002020
ZA003220
ZA003230
ZA003240
ZA008430
VF 1
VFF 1
VFF 1 1/4
VFF 1 1/2
VFF 2
VAR 1
VAR 1 1/4
VAR 1 1/2
VAR 2
RVFF 2
1
PLASTIC FOOT VALVE
1
BRASS FOOT VALVE WITH STAINLESS STEEL FILTER
1 1/4 BRASS FOOT VALVE WITH STAINLESS STEEL FILTER
1 1/2 BRASS FOOT VALVE WITH STAINLESS STEEL FILTER
2
BRASS FOOT VALVE WITH STAINLESS STEEL FILTER
1
BRASS NON RETURN VALVE
1 1/4 BRASS NON RETURN VALVE
1 1/2 BRASS NON RETURN VALVE
2
BRASS NON RETURN VALVE
2
BALL VALVE WITH FULL BORE
ZA009330
VRP 1 1/4
ZA009320
VRP 1 1/2
ZA009310
VRP 2
ZA006450
ZA006460
ZA006570
ZA006470
ZA006610
ZA007000
D3114KKK
D3104KKK
VES INOX N 8
VES INOX N 20
VES INOX N 24
VES INOX N 24 H
VAA 24
KAA
FLEXINOX V 20
FLEXINOX SB 20
ZA003860
ZA000140
ZA003850
ZA009120-CE
ZA009070-CE
ZA009130-CE
ZA009080-CE
ZA009090-CE
ZA009100-CE
ZA009110-CE
VES 2
VES 24
VES 24 H
VEC 60 H
VEC 60 V
VEC 100 H
VEC 100 V
VEC 200 V
VEC 300 V
VEC 500 V
208
PRICE
ACCESSORIES
HYDRAULIC ACCESSORIES
CODE
D6024KKK
ZA006380
ZA003050
ZA000790
ZA009190
ZA009200
ZA009210
ZA009220
ZA009230
CODE
MODEL
MBF
MBB
MGS 2
MGS 24
MB 60
MB 100
MB 200
MB 300
MB 500
DESCRIPTION
PRICE
MODEL
DESCRIPTION
PRICE
ZA008290
CS 85
ZA008310
RS 170
m
nom.
DESCRIPTION
ZB401390
ZB900010
5 FILTER 1 CONNECTION
ZB900060
7 FILTER 1 CONNECTION
ZB900020
ZB900030
10 FILTER 1 CONNECTION
ZB900070
ZB401350
20
20
ZB401370
60
20
ZB401410
20
20
ZB401460
20
20
ZB401550
60
20
ZB401540
60
20
ZB401360
20
20
ZB401570
20
20
ZB401380
60
20
60
20
1/4
CONNECTION
ZB401580
ZB401420
60
20
ZB401620
ZA006640
20
ZB401470
60
ZB401480
80
ZB401500
5 CARTRIDGE KZ (QUARTZ)
30
ZB401560
60
ZB401510
80
ZB401530
7 CARTRIDGE KZ (QUARTZ)
30
ZB401590
80
ZB401610
10 CARTRIDGE KZ (QUARTZ)
30
In exhaustion
209
PRICE
ACCESSORIES
ELECTRICAL ACCESSORIES
CODE
MODEL
UZB00500
AQUA MATIC
UZB00600
AQUA MATIC
DESCRIPTION
PRICE
(wired)
UZB00200
AQUA TROL
UZB00400
AQUA TROL
(wired)
ZA003110
PM 5 ITAL
PRESSURE SWITCH
- 6 ATM - ITALTECNICA
ZA006400
PM 12 ITAL
PRESSURE SWITCH
- 12 ATM - ITALTECNICA
ZA000630
PT 6 TEL
PRESSURE SWITCH
- 6 ATM - TELEMECANIQUE
ZA000640
PT 12 TEL
PRESSURE SWITCH
- 12 ATM - TELEMECANIQUE
ZA000590
MICROSTART 3-3
ZA000330
MICROSTART 10-3
ZA000650
MICROSTART 5-2
ZA000750
MICROSTART 10 -2
ZA000350
MICROSTART S 5-2
ZA000390
MICROSTART S10-2
ZA000820
CP
ZA008120
MERCURY 15 M
ZA000420
CAVO 4 x 1
ZA000430
CAVO 4 x 1,5
ZA000440
CAVO 4 x 2,5
ZA000450
CAVO 4 x 4
ZA000460
CAVO 4 x 6
ZA000470
CAVO 4 x 10
ZA003370
GIUNZIONE 2,5
ZA003390
GIUNZIONE 6
ZA003380
GIUNZIONE 10
2
2
2
WIRES
WIRES
2
210
ACCESSORIES
CONTROL PANELS
AMC 10
AMCS 10
AM 10
AT 10
AD 10
AY 10
AR 10
AA 10
ADRM 10
211
ACCESSORIES
CONTROL PANELS
ADRD 10
ADRY 10
ADRM 20
ADRD 20
ADRY 20
QES M
QES T
QES
212
ACCESSORIES
CONTROL PANELS
CODE
MODEL
VOLTAGE
at 50 Hz
RANGE
CAPAC.
1~230
1~230
1~230
1~230
1~230
1~230
Control Panels pre-set for level control for 1 single phase Submersible pump
1~230
1~230
1~230
1~230
1~230
1~230
Control Panels pre-set for level control for 1 single phase Submersible pump
1~230
1~230
1~230
1~230
1~230
Control Panels pre-set for level control for 1 three phase Submersible or Surface-Centrifugal pump - Direct Start
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels with level control device for 1 three phase Submersible or Surface-Centrifugal pump - Direct Start
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
213
PRICE
ACCESSORIES
CONTROL PANELS
CODE
MODEL
VOLTAGE
at 50 Hz
RANGE
Amin.
Amax.
CAPAC.
Control Panels with level control device for 1 three phase Surface-Centrifugal pump - Star/Triangle Start
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels with level control device for 1 three phase Submersible pump - Reactance Start
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels with level control device for 1 three phase Submersible pump - Auto-Transformer Start
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels for 1 single phase Sump, Sewage and Effluent pump
1~230
1~230
1~230
1~230
1~230
214
PRICE
ACCESSORIES
CONTROL PANELS
CODE
MODEL
VOLTAGE
at 50 Hz
RANGE
Control Panels for 1 three phase Sump, Sewage and Effluent pump - Direct Start
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels for 1 three phase Sump, Sewage and Effluent pump - Star/Triangle Start
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels for 2 single phase Sump, Sewage and Effluent pumps
1~230
1~230
1~230
1~230
1~230
Control Panels for 2 three phase Sump, Sewage and Effluent pumps - Direct Start
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
Control Panels for 2 three phase Sump, Sewage and Effluent pumps - Star/Triangle Start
3~400
3~400
3~400
3~400
3~400
3~400
3~400
3~400
215
CAPAC.
PRICE
ACCESSORIES
CONTROL PANELS
CODE
VOLTAGE
at 50 Hz
MODEL
PRICE
CODE
PRICE
MODEL
Electrodes for conductive fluids level control
12Vcc Acoustical and Optical Alarm system for Sump, Sewage and Effluent pumps Control Panels
MODEL
DESCRIPTION
QES HP 0,5 M
QES HP 0,5 T
QES HP 0,75 M
QES HP 0,75 T
QES HP 1 M
QES HP 1 T
QES HP 1,5 M
QES HP 1,5 T
QES HP 2 M
QES HP 2 T
QES HP 3 T
QES HP 4 T
PRICE
MODEL
DESCRIPTION
ZQ001000
QEF-26
FOR MODELS:
ZQ001010
QEF-37
216
PRICE
12
10
- Plug
with built in thermal protection and switch for
manual/automatic operation.
250
/10
16
0/ 8
2
Hm
Q
50
3
L / 1'
m3/ h
200
12
150
9
100
6
250
15
300
18
Usage Limitations
- Type of liquid: partially effluent and dirty clear water,
with suspended solids of a maximum dimension of
6 mm, non-aggressive liquids
- Maximum liquid temperature 40C
Accessories (only on request)
- Sealing lid to be fitted in place of the grid
(see page 209)
CODE
MODEL
Nominal
Power
Absorbed
Power
HP
kW
HP
VOLTAGE
Amp.
F.
L/1'
N2141000
VS 85-D 160
0,5
0,37
0,6
2,2
N2141010
VS 85-D 250
0,75
0,55
1,2
0,9
1 ~ 220 240 V
4,5
10
217
40
60
80
0,6
2,4
3,6
4,8
7,2
5,8
4,1
2,2
9,4
8,5
7,6
7,2
5,1
PRICE
3
m /h
kW
10
Discharge
Head
in meters
9,6 14,4
4,1
18
VACUSYSTEM
MINI COLLECTION AND PUMPING
STATIONS FOR WASTE WATER
The VACUSYSTEM 170s are pre-assembled, readyfor-use automatic pumping stations, designed for the
disposal of waste and sewage water.
Particularly suitable when the water from drains is
collected at a lower level than the main sewer.
Design Features
- The standard pumping station consists of:
- Tank
In polyethylene with a capacity of 170 litres with screwdown lid. Three possible types of inlet for water
collection or ventilation pipe inlet and cable glands for
the electric pump power supply cable and service
cables (overflow float on request).
- BIOX Submersible Pump
Models 200/8 AUT, 300/10 AUT, 400/12 AUT with cast
steel impellers .
14
12
- Plug
with built in thermal protection and manual/automatic
switch.
10
40 0
/12
300
/10
20
0/8
4
2
Hm
Q
50
3
L / 1'
m3/ h
100
6
200
12
150
9
250
15
300
18
350
21
400
24
450
27
N2141030
N2141040
N2141050
MODEL
Nominal
Power
Absorbed
Power
VOLTAGE
Amp.
F.
L/1'
kW
HP
kW
VS 170-B 200 I
0,8
0,6
1,2
0,9
1 ~ 220 240 V
4,1
12,5
VS 170-B 300
1,2
0,9
1,7
1,3
1 ~ 220 240 V
5,8
20
VS 170-B 400
1,6
1,2
2,2
1,6
1 ~ 220 240 V
7,2
20
218
m /h
HP
50
Discharge Head
in meters
CODE
12
15
18
21
7,8
6,3
4,6
0,5
9,8
8,7
7,5
6,3
4,7
0,5
8,3
7,1
5,8
4,2
24
2,5
10
40 0
/12
300
/10
Hm
Q
50
3
L / 1'
m3/ h
100
6
200
12
150
9
250
15
300
18
350
21
400
24
450
27
Usage Limitations
- Type of liquid: sewage water, with suspended solids
of a maximum dimension of 40 mm.
- Maximum liquid temperature 50C
Accessories (only on request)
- Screw-down tank extension
(see page 209)
- Threaded ball check valve 2" F
(see page 208)
- Ball valve with threaded full bore 2" F
(see page 208)
- Overflow float
(see page 210)
MODEL
Nominal
Power
Absorbed
Power
HP
kW
HP
kW
VOLTAGE
Amp.
F.
L/1'
3
m /h
N2141060
1,2
0,9
1,7
1,3
1 ~ 220 240 V
5,8
N2141070
1,2
0,9
1,7
1,3
3 ~ 400 V
2,2
N2141080
1,6
1,2
2,2
1,6
1 ~ 220 240 V
7,2
N2141090
1,6
1,2
2,2
1,6
3 ~ 400 V
2,5
219
20
20
50
Discharge Head
in meters
CODE
PRICE
3
9,8
9,8
12
15
18
21
24
8,7 7,5
6,3
4,7
0,5
8,7 7,5
6,3
4,7
0,5
8,3
7,1
5,8
4,2
2,5
8,3
7,1
5,8
4,2
2,5
VACUSYSTEM
MINI COLLECTION AND PUMPING
STATIONS FOR WASTE WATER
The VACUSYSTEM 400 TWINs are pre-assembled,
ready-for-use automatic pumping stations, designed
for the disposal of waste and sewage water.
Particularly suitable when the water from drains is
collected at a lower level than the main sewer.
Design Features
- The standard pumping station consists of:
- Tank
In polyethylene with a capacity of 400 litres with screwdown lid.
Three possible types of water collection or ventilation
pipe inlet and cable glands for the electric pump power
supply cable and service cables (overflow float on
request)
- Pair of BIOX Submersible Pumps
Models 300/10 and 400/12 with cast steel impellers.
- Two Stainless Steel Connecting Foot
10
40 0
/12
300
/10
2
Hm
Q
50
3
L / 1'
m3/ h
100
6
200
12
150
9
300
18
250
15
350
21
400
24
450
27
Usage Limitations
- Type of liquid: sewage water, with suspended solids
of a maximum dimension of 40 mm.
- Maximum liquid temperature 50C
Accessories (only on request)
- Screw-down tank extension
(see page 209)
- Threaded ball check valve 2" F
(see page 208)
- Ball valve with threaded full bore 2" F
(see page 208)
- Overflow float
(see page 210)
MODEL
Nominal
Power
Absorbed
Power
HP
kW
HP
kW
VOLTAGE
Amp.
F.
L/1'
3
m /h
N2141100
1,2
0,9
1,7
5,8
N2141110
1,2
0,9
1,7
1,3
2,2
N2141120
1,6
1,2
2,2
7,2
N2141130
1,6
1,2
2,2
1,6
2,5
3 ~ 400 V
3 ~ 400 V
220
20
20
50
Discharge Head
in meters
CODE
PRICE
3
12
15
18
21
9,8
8,7
7,5 6,3
4,7
0,5
9,8
8,7
7,5 6,3
4,7
0,5
24
8,3 7,1
5,8
4,2
2,5
8,3 7,1
5,8
4,2
2,5
by
STA-RITE
S.p.A.
SUPPLIES
Agreements or promises that are different from the normal conditions of supply are not recognised unless signed in the purchase order and
duly approved by STA-RITE S.p.A.
GUARANTEE
This device is covered by legal warrantee according to the laws and norms in force on the date and in the country of purchase, relatively to
flaws and defects in manifacturing and/or materials used. Our guarantee is limited to the replacement or repair, in our workshop and by us, of
the pump or part that is identified as being faulty. In no case however does the guarantee involve the possibility of requesting compensation.
Breakdowns caused by errors in electrical connection, by a lack of adequate protection, by defective assembly, by incorrect action or by a lack
of care in producing the equipment are excluded from the guarantee:
- breakdowns caused to the materials due to corrosion or abrasions of any type and nature caused by the pumped liquid:
- incorrect operation due to installations not performed in a perfectly workmanlike manner;
- where the Customer is not up-to-date with payments.
In particular our guarantee is void where our submersed or submersible pumps (three phase or single phase) have not been installed with the
control and protection equipment specified by us. In the absence of documentation proving the date of shipment, the age of the pump will be
determined from the code given in the identification plate. Finally material removed, repaired or tampered with by any person not expressly
authorised by us to do so is excluded from our guarantee.
The faulty material must be returned to our workshops carriage free and, once it is identified that the fault comes under our responsibility, it
will in turn be returned carriage free.
TESTS
Tests are undertaken at our workshops in the presence of the customer if this is required. The curves are considered valid for the rotation speeds
given in the tables: tolerance according to ISO 2548 standards - C. Head and NPSH values valid for water with a specific weight of 1 kg/dm3
at 20 C.
DISPUTES
There may be no exception to the conditions stated above unless expressed and accepted in writing. The resolution of any dispute falls within
the jurisdiction of the Court of Pisa, even if the payment is agreed by means of a draft.
This Catalogue replaces and cancels all previous ones
BENELUX