AT235-AT235h - Technical Specifications

Page 1

Technical Specifications

AT235-AT235h Impedance Audiometer

Item No. 8011689 Rev. 2 11/2011

AT235-AT235h - Technical Specifications

Page 2

General Technical Specifications


Standards: Audiometer Impedance Safety

: : :

IEC60645-1, ANSI S3.6, Type 4 IEC 61027, ANSI S3.39, Type 2 IEC60601-1, Class 1, Type B, EMC: IEC60601-1-2

The CE mark indicates that the instrument is made to fulfil the demands of the Council Directive 93/42/EEC concerning medical devices and that TV Product Service, identification no. 0123, has approved the quality system of Interacoustics. Impedance: Probe Tone Frequency: High Freq. Probe Tones: Probe Tone Intensity : Pressure Range : Accuracy : Compliance Range : High Frequency : Compliance Accuracy : 226 Hz 1% 678, 800 and 1000Hz. 85 dB SPL 1.5 dB +300 to -600 daPa 5% or 10 daPa 0.1-6 ml. 0.3 12 mmho 5% or 0.1 ml.

Reflex: Manual or automatic testing with 18 stimuli to each ear. Auto Reflex Detection. Multiple Reflex stimuli. Stimulus Duration : 1.0 sec. Reflex Acceptance : Adjustable between 2% and 6%, or 0.05 0.15 ml change of ear canal volume. Ipsi Frequencies : 500, 1000, 2000, 3000, 4000 Hz, wide band, high and low pass. Intensity (Max.) : 100, 105, 110 dBHL. Contra Frequencies : 250, 500, 1000, 2000, 3000, 4000, 6000, 8000 Hz, wide band, high and low pass. Intensity (Max.) : 90, 100, 120, dBHL. Reflex Decay: Stimulus Duration Stimulus Frequency Stimulus Intensity

: : :

10 sec.

Ipsi and Contra as above.

Audiometer: Type 4 according to IEC60645-1, ANSI S3.6. Frequencies Hz: 125 250 500 1000 2000 3000 4000 6000 8000 Intensities dBHL: -10 to 90 -10 to 90 -10 to 120 -10 to 120 -10 to 120 -10 to 120 -10 to 120 -10 to 120 -10 to 110

Auto Threshold Determination (Modified Hughson Westlake).

AT235-AT235h - Technical Specifications

Page 3

Tests: Tympanometry : Reflexometry incl. decay: Audiometry : Eustachian Tube :

Automatic or Manual Automatic or Manual. Manual or Auto Threshold (Patient controlled Hughson Westlake test after ISO 8253) Semi Automatic function test. Williams Test (non perforated eardrums)

Calibration: Impedance : IEC61027, ANSI S3.39 Audiometer : ISO 389-1, ANSI S3.6 Calibration is performed via the instrument's front panel and is stored in a permanent memory. Computer Communication: Built-in USB input/output computer interface. One mode allows the computer to both monitor and control the AT235. Control actions will be indicated on the operation panel and the display. Power supply: 100-240V~50/60Hz Fuses: 2A Consumption: 15VA, max. 45VA. The AT235 is delivered with a power cord for the relevant national mains socket. But AT235 can be powered by any national AC voltage - Before use, the correct attachment plug/mains cable must be identified and installed. Dimensions: W x D x H: 32 x 32 x 10.2 cm, 16.5 x 12.5 x 4 inches. Weight: 4.1 kg / 9.0 lbs.

AT235-AT235h - Technical Specifications

Page 4

Included and Optional Parts


Included Parts: ATP-AT235u Universal probe system with shoulder strap and wrist strap TSH39 Single contralateral headset UPS400 external switch mode power supply Power cable BET55 Box of 65 assorted ear tips TPR26 3 rolls of recording paper PCR-AT235h dust cover Operation Manual. Multilingual CE instructions for use

Additional Parts: TDH39 audiometric headsetACC226 Carrying Case EARtone 5A Audiometric Insert Phones ACC25 carrying case CIR33 contralateral insert phone APS2 patient signal CAT40 calibration unit 0.2-0.5-2.0-5.0 ml CAT227 calibration unit 0.2-0.5-1-2-3-4-5 ml IES impedance ear simulator USB cable 2m black