Hepco has distributed ASKs linear motion products exclusively for over 20 years. The current range continues ASKs tradition of offering designers and engineers the highest quality linear bearings standard linear ball bushings are complemented by

a wide variety of flanged units and housings for ease of installation. The combination of the best application advice from Hepcos Technical Sales Team and the wide ASK range means Customer requirements are met exactly.

B A L L B U S H I N G S
A quality range of precision bearings with plastic retainers. A very competitively priced product with no sacrifice to quality. Also includes a range of long series ball bushings with extra rigidity.

N F S E R I E S
A compact ball bushing with integral outer case and flange. This product with its machined datum face offers the designer a unique compact and very simple solution for mounting a datum platform perpendicular to the direction of travel.

N F L O N G S E R I E S
A very versatile range of products. Two flange profiles and two methods of location. In addition the longer bearing length gives much greater rigidity and load capacity.

L C F - B F L A N G E D H O U S I N G S
For more arduous applications than the NF long type product the use of the LCF flanged housing is recommended. With a longer distance between the two separate internal ball bushings this product offers even greater rigidity and load carrying capacity. Location on both sides of a spigot flange are offered, as is the capability to connect to a central lubrication system.

L C H O U S I N G S
For applications where the datum face is required to be mounted in the same plane as the direction of travel the LC housing offers the designer a very effective off the shelf solution. The simple four fixing hole arrangement with machined datum faces also offers the ability of fixation from either side.

B A L L

B U S H I N G

U N I T S

L C

S E R I E S

G G G

Lightweight aluminium housing 4 fixing holes allow simple mounting to plate Can be fixed from either side

W W2 E W2

4-S1

L F W2

W E W2

4-S1

L F

h2

h1

W1

4-S2 W1 4-S2

LC-8VUU12VUU

LC-12VUU30VUU
W E L F

W2

W2

4-S1 Heli-sert on
10

h1

h2

W1

LC-40VUU

Note: Grease nipple attached (A-PT 1/8)

h3

4-S2

h3

h3

h1

h2

Reference Number LC-8VUU

Main Dimensions d 8 h1 0.02 13 15 19 11 W 34 40 43 50 76 54 E 0.1 28 36 54 58 24 W1 0.02 20 25 38 39 17 W2 5 6.25 h2 8 h3 20 21 H 22 L 30 F 18 S1 M4 M5 M5 M8 M6 S2 3.4 4.3 4.3 6.9 9

Weight (kg)

LC-10VUU LC-12VUU LC-16VUU

10 12 16

30.5 40

21.5

6 7

10 12 12

12

23.5 28 37

26 29 37 51 41

36 39 55 49 73

26 40 34 50

21

M5

4.3

0.069 0.10 0.18

0.040

Basic Load Capacity C C (kgf) (kgf) 38 27 43 23

42 79

44 103 72

LC-20VUU

LC-25VUU LC-30VUU LC-40VUU

20

25 30

26 40 30

21

27

40

110

78

80

55

10 15

11

18 20 18

32

5.1

0.23

43

60

78

57

80

80

60

58

M10

M8

6.9

0.53 1.54

0.63

104 280 148

88

200 443 255

Note: All LC Series units are supplied with seals both ends.

B A L L
W I T H

B U S H I N G
F L A N G E

U N I T S

L C F - B . B L

S E R I E S

G G G G G

Ideal for arduous applications Connections for (manual or automatic) lubrication Greater rigidity High load / moment load capacity Location diameter on both sides of spigot
1000Nm
4-a Mounting hole W W1 f c T e Screw for grease nipple M6 P=0.75

DYNAMIC LOAD CAPACITIES


(See table below)

800Nm 600Nm

W1

Df

D1

400Nm 200Nm

0
20mm
NF long LCF-B LCF-BL

25mm 54 243 464

30mm 86 523 862

33 111 206

Reference Number LCF-12BUU LCF-16BUU LCF-20BUU

Main Dimensions d 12 20 16 D h7

26 40 32 45 52 65 32

72 76

0 0.3

Df 48 73 58 83

W 36 53 45 62 82 53

T 8

W1 26 40 32 45 65 40

a 6

0 0.3

e 8

f 36 41

D1 25 39 31

Number Weight of Ball Circuits (kg) 5 6 5 0.25 0.65 1.36 2.12 0.38

LCF-25BUU LCF-30BUU LCF-40BUU LCF-16BLUU

25 30 40 16

102 144 120 122

82

10 12 12 15

8 8

Basic Load Capacity C Co (kgf) (kgf) 123 166 130 278 158 90

Moment Load Capacity Dyn Stat Nm Nm 46 65

LCF-20BLUU

LCF-25BLUU LCF-30BLUU LCF-40BLUU

20

30

25 40

52

45 65

40

100

112 73

94

69 45

15

52 32

9 9 9

12 12 12 8

10 12 12

38 51

34 51

15 15

58

10 12 12 15 15

240

180

150

83 94

112

69

62 82

52

45 65

9 9

12

12 12

10 12 12 15 15

72

61

44

38 51 61

64

51 31

6 6 5

0.88

459

257

41

44 51

39

72

64

0.85 1.77 3.15 1.15

0.45

1131 257

721

166

652 158

394

523

243

111

130

820

286 473 82

147

68

464 1131 721

278 652 394

206 862

104

464

278 471

126

1973

1137

Note: 1 To the axis, the concentricity of outer surface of the case and squareness of mounting face
of the flange are below 0.025 respectively. 2 The shaft tolerance of h7 for normal clearance and h6, h5 for tight clearance are advisable. 3 All mounted with specific seals at two ends.

B A L L

B U S H I N G S

L N L

S E R I E S S E R I E S

G G G

Plastic retainers for quiet operation Metric dimensions for European market NL long series for greater rigidity
L B W W

D1

L SERIES

Reference Number

With two seals L-6VUU L-10VUU L-16VUU L-12VUU L-8VUU

Inside Diameter d Tolerance 6 10 12 16 8

Outside Diameter D Tolerance 12


0 -0.008 0 -0.009 0 -0.011 0 -0.013

Length L 19 Tolerance B 13.5 21.9

Setting Groove Tolerance W 1.15 D1 11.5

L-6V L-10V L-16V L-12V L-8V

Number Weight of Ball Circuits (kg) 4 4 4 0.014

+0.008 0 +0.009 -0.001 +0.011 -0.001


+0.013 -0.002

16 19

25 29 32 36 45 58 68 80 0 -0.2

16.5 0 -0.2

1.15

22

L-20V L-30V

L-25V

L-20VUU L-30VUU

L-25VUU

20 30

25

32

26 40

22.9 25 31.5

1.35

1.35

1.35

21.0

18.0

15.2

0.007

Basic Load Capacity C Co (kgf) (kgf) 27 21 23 13

L-40V
NL SERIES

L-40VUU

40

62

47

0 -0.3

44.1

1.65 1.90

30.3 38.0 59.0

24.9

5 6 6

0.054 0.212

0.032

0.030

0.090 0.330

60

42

38

44 103 66

43

52.1

60.7

0 -0.3

2.20

1.90

45.5

104 280 148

88

200

0.780

443

255

Reference Number

With two seals NL-8VUU NL-10VUU NL-16VUU

Inside Diameter d Tolerance 8

Outside Diameter D Tolerance 15 21 19

Length L 45 Tolerance B 35

Setting Groove Tolerance W 1.10 -0.3 0 -0.4


0

D1 14.3 20 18

NL-8V

Number Weight Basic Load of Ball Capacity Circuits C Co (kg) (kgf) (kgf) 4 4 0.028 0.064 0.140 0.180 0.060 45 63 86 64

NL-12V NL-16V

NL-10V

NL-12VUU

10 12 16

0 -0.010

NL-30V

NL-25V

NL-20V

NL-25VUU

NL-20VUU

NL-30VUU

25

20

28

0 -0.016 0 -0.019

55 70 57

-0.3 0 -0.4

44 46 53

1.35 1.65

30

0 -0.012

32 40

45

123

112

80

82 89

61

1.90

38 43

30.5

27

0.424

148 247 174

125

70

0.480

400

206 510

158

88

B A L L
W I T H

B U S H I N G
F L A N G E

U N I T S

N F

S E R I E S

G G G

Compact bushing with integral outer case Machined datum for end face mounting Outer location diameter

4-Mounting hole

L T

PC D
Df

Reference Number NF-8VUU

Main Dimensions d 8 -0.009 0 0 Tolerance D h1 L 24 -0.2 0 Tolerance Df 32 42 W 25 32 T 5 PCD 24

NF-10VUU NF-12VUU NF-16VUU

10 12 16

16 19

Number Weight Basic Load of Ball Capacity Clamping Circuits (kg) C Co Bolt (kgf) (kgf) M4 M3 4 4 0.06 0.10 0.18 0.04 0.08 38 27 43 23

22 32 26

30 36

29

39

30

NF-20VUU NF-25VUU NF-30VUU

20

25 30

NF-40VUU

NF-35VUU

35

-0.010 -0.012 0

40 47

58 70

42 64 0

46

62 82

54 76

42

35

29

32

50 64

36 51

M4

40

52

60

80

-0.3

60

10 10 13

43

M4

62 78 67

M5 M6 M6

M5

42

6 6 6

60

44

0.30 0.59 1.21 0.55

102 148 167

88

200 255

103

66

96

75

M8

280

443

314

Note: The squareness of datum face of the flange to axis: below 0.012 for 8~16.
below 0.015 for 20~30 below 0.020 for 35~40.

B A L L

B U S H I N G
W I T H

U N I T S
F L A N G E

N F

L O N G

S E R I E S

G G

Longer series than NF type Spigot type for end location and mounting
NFID NFED NFIO NFEO
W

G G

Oval flange where space is a premium Long series for greater rigidity

L C T

PCD

4-Mounting hole Clamping bolt

2-Mounting hole Clamping bolt

SPIGOT TYPE

Reference Number

Main Dimensions d 8 0 -0.010 Tolerance D 15 21 19 Tolerance 0 -0.013 0 -0.016 0 -0.019 L 45 57 0 -0.3 Tolerance Df 32 T 5 C 5 W N/A 21 N/A 25 N/A 27 N/A N/A N/A N/A PCD 24

Df

NFID-8VLUU NFIO-8VLUU NFID-10VLUU NFIO-10VLUU NFID-12VLUU NFIO-12VLUU NFID-16VLUU NFID-20VLUU NFID-25VLUU NFID-30VLUU Reference Number

Clamping (kg) Bolt M4 M4 M3

Weight

10

12 16

55 70

20 30 25

28 0 -0.012 40

32

45

123

112

80

0 -0.4

54

48

42

40

6 8 6

29 38 32

62

74

10

10

43

M4

0.048 0.042 0.088 0.078 0.093 0.083 0.170 0.247

Basic Load Capacity C Co (kgf) (kgf) 63 125 174 70 45 60 152 86 32

Moment Load Capacity Dyn Stat Nm Nm 10 26 11 6 9 4

60

51

M6

M5

M5

0.502 0.631

148

206

247

386

33

452

54

86

120

46

31

12

157

END FLANGE TYPE

Main Dimensions Tolerance D 15 0 -0.010 21 19 Tolerance 0 -0.013 0 -0.016 0 -0.019 L 45 55 70 112 57 0 -0.3 Tolerance Df 32 40 48 0 -0.4 42 T 5 6 6 C 0 0 0 W N/A 21 N/A 25 N/A 27 N/A N/A N/A N/A PCD 24

d 8

NFED-8VLUU NFEO-8VLUU NFED-10VLUU NFEO-10VLUU NFED-12VLUU NFEO-12VLUU NFED-16VLUU NFED-20VLUU NFED-25VLUU NFED-30VLUU

Clamping (kg) Bolt M3 M4 M4

Weight

10 16

12

29

20 25

30

0 -0.012

32

28

40

80

54

45

123

62

74

10

38 51

32 43

M4

0.048 0.042 0.088 0.078 0.093 0.083 0.170 0.247

Basic Load Capacity C Co (kgf) (kgf) 45 63 32 60

Moment Load Capacity Dyn Stat Nm Nm 10 26 11 6 4 9

M5

60

M5

M6

0.502 0.631

148

125

70

247

174

206

152

86

386

33

452

54

86

120

46

31

12

157

A P P L I C AT I O N

E X A M P L E S

NF LONG (SPIGOT FLANGE)

LC ALUMINIUM HOUSING

NF LONG (END FLANGE)

LCB-B TYPE

Hepco Slide Systems Ltd Tiverton Way, Tiverton, Devon EX16 6TG Tel: 01884 257000 Fax: 01884 243500 E-mail: hepco.sales@hepco.co.uk Website: www.hepco.co.uk