Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
circuit protection
width in mod. of 9 mm 2
24395
1 protected pole
2P
1 3
2 4
2 4 6
1 3 5 7
2 4 6 8
rat (A) 1 2 3 4 6 10 16 20 25 32 40 50 63 1 2 3 4 6 10 16 20 25 32 40 50 63 1 2 3 4 6 10 16 20 25 32 40 50 63 1 2 3 4 6 10 16 20 25 32 40 50 63
Cat No. C curve 24395 24396 24397 24398 24399 24401 24403 24404 24405 24406 24407 24408 24409 24331 24332 24333 24334 24335 24336 24337 24338 24339 24340 24341 24342 24343 24344 24345 24346 24347 24348 24349 24350 24351 24352 24353 24354 24355 24356 24357 24358 24359 24360 24361 24362 24363 24364 24365 24366 24367 24368 24369
C curve
Application control and protection of circuits against overloads and short-circuits. c in domestic installation; c in commercial and industrial electrical distribution systems; Technical data c current rating: 1 to 63 A; c voltage rating: 230-400 V AC; c breaking capacity: v Icn ultimate breaking capacity (O-CO cycle):
rat. type (A) to IEC 898 1 to 63 1P 2, 3, 4P voltage (V) 230-240 400-415 breaking capacity (A) 6000 6000
2, 3, 4P
c fast closing contacts; c number of operating cycles (O-C); 20000; c tripping characteristics: v C curve: the magnetic releases operate between 5 and 10 In; c impulse withstand voltage (U imp.): 6 kV; c tropicalization: treatment 2 (relative humidity 95% at 55C); c weight (g):
type 1P 110 2P 220 3P 340 4P 450
c connections: tunnel terminals for rigid cables up to: v 25 mm2 for rating < 25 A, v 35 mm2 for rating 32 to 63 A; c approvals: Marine, (consult us) c installation: in all enclosures designed for Multi 9 equipment.
additional information
Merlin Gerin
circuit breakers
C60 N UL 489
CSA 22.2 No 5.1 UL Listed for branch circuit protection DC
Main functions of C60N UL 489 circuit breaker: - protection of circuits against: - short circuit currents - overload currents - control - isolation Various applications: - semi-conductors - electronic machinery - control panel - metal working - telecommunication - food, beverage - packaging - crane - conveyors - pumps and compressors - HACR (Heating, Air conditioning, Refrigeration) - engine generators
Compliance with standards c UL 489 circuit breakers File #E215117 c CSA C22.2 No. 5.1 circuit breakers File #179014 c IEC 60947-2, VDE 0660 c CE Marked Standard features c Power circuit: v voltage rating: 120 up to 240 Vac (delta) v ampere interrupting ratings:
rating (A) 77F/25C 0.5-35 number of poles 0.71 in. (18 mm) 1P 2P/3P voltage interrupting rating (kA rms) UL 489 / CSA 10 5 10 -
1P 2P
120 Vac 240 Vac 240 Vac 415 Vac 440 Vac 65 Vdc 125 Vdc
IEC 60947.2 10 20 10 6 10 10
v fast closing: allows increased withstand of the high inrush currents of some loads v current limiting v trip-free mechanism: contacts cannot be held in the ON position when the circuit breaker is tripped automatically v isolation with position break indication - Green strip on the circuit breaker operating handle indicates that all poles open v number of operating cycles (0-C): - electrical: 10,000 - mechanical: 20,000 c Environment: v tropicalization: treatment 2 (relative humidity: 95% at 131F/55C) v degree of protection: - case: IP40 as per IEC 60529 - terminals: IP20 v temperature: -operation: -22 to 158F (-30 to 70C) - storage: -40 to 176F (-40 to 80C) c Weight (oz./g):
type C60N 1P 3.88/110 2P 7.75/220 3P 11.64/330
058976N
Merlin Gerin