Sei sulla pagina 1di 11

AIR BREATHER

FILTERS

The comprehensive series of breather filters makes it possible to

Temperature

meet all market demands. Metal and plastic styles suitable for use

from -25C to +100C

on mobile equipment are available.


The function of breather filters is to intercept environmental
contamination.
The correct use of breather filters ensures longer life of filter
cartridges installed in the hydraulic circuit, and in applications
where high level of contamination are present.
The use of breather filters calls for the simultaneous installation
of plugs for filling and topping up fluids; it is recommended to use
plugs complete with basket for correct prefiltration of the fluid.
If the filler plug is equipped with a filter, the filtration degree must
be the same as that of the breather filter.

34

Compatibility
NBR seals and Cork Gasket, compatible with:
Mineral oils to ISO 2943 - aqueous emulsions
Synthetic fluids, glycol water.
FPM seals, compatible with:
Synthetic fluids type HS-HFDR-HFDS-HFDU.

Metal air breather filter

Series

TA 4 6

Dimens ions
Threaded connection
TA46G-N...P01
46

With filter

40

13

A/F 16
(mm)
A

TA46 G - N (Materials)

Flow rate with p: 0,02 bar

1 - Cover: Chrome plated steel

Filtration

2 - Filter element: Impregnated paper


Polyurethane

lN/min

3 m

150

Connection

10 m

200

G 1/4
1/4 NPT

3 - Flange: Galvanised Steel


4 - Threaded connection: Phosphated Steel

Weight
TA 46: 0,110 kg

Or dering i nfor mation


Breather filter

03

P01

TA46
Example: TA46

1 - Connection to reservoir
G

G 1/4

1/4 NPT

3 - Options
P01

MP Filtri standard

2 - Filter element
03
10

3 m - Impregnated paper
10 m - Polyurethane

35

Series

TA 8 0

Metal air breather filter

TA80.....P01

Or dering i nfor mation

With filter

Breather filter

03

P01

TA80
Exemple: TA80

1 - Connection to reservoir

4 - Valves

G 3/4

Without

3/4 NPT

0,3 bar pressurisation valve

0,7 bar pressurisation valve

2 - Filter element

TA80.03.9P01
With anti-splash feature

3 m - Impregnated paper

03

10 m - Polyurethane

10

5 - Options
P01

3 - Seal

Without

NBR (pressurised only)

Anti-splash feature
(only with filter element 3 m)

MP Filtri standard

TA80
TA80....1P01
With filter and
pressurisation valve

1
2

Flow rate with p: 0,02 bar


3

lN/min

Filtration
3 m

450

10 m

550

4
5

Weight
TA 80: 0,350 Kg

Dimensions
Threaded connection
80

TA80 G (Materials)
1 - Cover: Chrome Plated Steel

55

2 - Filter element: Impregnated paper


Polyurethane
3 - Pressurisation valve: Nylon
Galvanised Steel
NBR

16

A/F 35
(mm)

36

Connection

G 3/4
3/4 NPT

4 - Flange: Galvanised Steel


5 - Threaded connection: Galvanised Steel
6 - Anti-slosh feature: Galvanised Steel

Nylon air breather filter

Series

TA P 9 0
TAP 90 G
With filter

Or der ing infor mation

1
Breather filter

2
TAP90
Exempie: TAP90

03

P01

4 - Pressurisation valve

1 - Connection to reservoir
G

M52x2

Without

G 1 1/2

0,3 bar pressurisation valve

G 1 1/4

0,7 bar pressurisation valve

3/4 NPT

1 NPT

G 3/4

03
10

3 m - Impregnated paper
10 m - Polyurethane

Standard

With Dipstick

With Padlock tab

With Dipstick and Padlock tab

P01

Without

NBR (pressurised)

3 - Seal: NBR

6 - Options

3 - Seal

1 - Cover/ringnut: Nylon
2 - Breather filter: Impregnated paper
Polyurethane

5 - Variants

2 - Filter element

TAP90 (Materials)

MP Filtri standard

Flow rate with p: 0,02 bar


Filtration

lN/min

3 m

450

10 m

550

Weight
TAP 90: 0,130 Kg
TAP G
With Pressurisation

Dimensions
TAP 90 for connection on weld flange
91
63

44

TAP G
With Dipstick

12

25

A
15

2 X 15

8,5

B
G
H
L
M
N
Q

M52x2
G 1 1/2
G 1 1/4
3/4 NPT

52,5
48,5
42
-

1 NPT
G 3/4

37

Nylon air breather filter

SAP 50

Series

Dimens ions
D1

H2

H3

H1

4
A

Connection to reservoir A

SAP050 (Materials)

Type SAP 50

1 - Cover/Connection: Nylon
2 - Filter element: Impregnated paper
Polyurethane

G1

G2

G3

G 1/4

G 3/8

G 1/2

G8
G7
G6
3/8 NPT 1/2 NPT 3/4 NPT

3 - Pressurisation: Nylon
Galvanised steel
NBR
4 - Seal: NBR

Type SAP D1
G4

SAP50

G5

G 3/4 1/4 NPT


G9

G10

SAE 6

SAE 12

Quantity per pack


Number of Parts

Flow rate with p: 0,02 bar


Filtration

Dimensions

10

H1

50 G1
50 G2
50 G3
50 G4
50,5 12
50 G5
50 G6
50 G7
50 G8
50 G9
50,5 14,5
50 G10

H2

H3

36

48

35

50

lN/min

10 m

204

Weights
SAP 050: 0,040 kg

Or der ing infor mation


Breather filter

G4

L10

P01

SAP
Example: SAP50

1 - Connection to reservoir

38

G1

G 1/4

G2

G 3/8

G3

G 1/2

G4

G 3/4

G5

1/4 NPT

G6

3/8 NPT

G7

1/2 NPT

G8

3/4 NPT

G9

SAE 6

G10

SAE 12

2 - Filter element
L03
L
L 10

3 m - Impregnated paper

Without

Pressurisation valve
0,5 bar
Only for connection:
G2 - G3 - G4 - G6
G7 - G8 - G10

10 m - Polyurethane

3 - Seal
A

4 - Pressurisation valve

NBR
5 - Options
P01

MP Filtri standard

Nylon air breather filter

Series

SAP 054 - 075


Dimens ions

H2

H3

Flow rate with p: 0,02 bar

1 - Cover: Nylon

Filtration

2 - Connection: Nylon

SAP 054

A/F

H1

SAP 054 - 075 (Materials)

lN/min
A

3 - Filter element: Impregnated paper


Weights

3 m

200

10 m

250

D1

SAP 075

SAP 054: 0,060 Kg

Connection to reservoir A

3 m

350

10 m

400

SAP 075: 0,150 Kg

Type SAP
054
075

G1

G2

G 3/8 G 1/2
G 1/2 G 3/4

G3

G4

G5

1/2 NPT
1/2 NPT

3/4 NPT

Dimensions
Type SAP

D1

H1

H2

H3

054 G1
054 G2
054 G4

54

13,5

51

075 G1
075 G2
075 G4
075 G5

75

A/F (mm)
22
27

17

64

32
27
32

Or dering i nfor mation


Breather filter

075

G4

L10

P01

A7

L10

SAP
Example: SAP

Filter element
Example:
1 - Size
Filter

3 - Filter element

2 - Connection to reservoir
Filter element

054

A4

075

A7

SAP 054

SAP 075

L03

3 m - Impregnated paper

G1

G 3/8

G 1/2

L10

10 m - Impregnated paper

G2

G1/2

G 3/4

G3

G4

1/2 NPT

1/2 NPT

G5

3/4 NPT

4 - Seal
A

NBR

5 - Options
P01

MP Filtri standard

39

Nylon air breather filter

SAP 115

Series

2
3

Clogging indicator
Set pressure: - 0.062 bar 10%
Manual reset

SAP115 (Materials)

Weight

1 - Cover: Nylon

SAP 115 1: 0,410 Kg

2 - Filter element: Microfibre


Impregnated paper

SAP 115 2: 0,525 Kg

3 - Connection: Nylon
4 - Seals: NBR
FPM

Dimensions
SAP 115 2

SAP 115 1 - Dimension

22

Visual
Indicator

SAP 115 1

H1

H1

22

Visual
Indicator

Connection

A/F

H1

H2

H3

A
B
C

G 1
M33x2
G 1 1/2

41
41
55

106
106
111

18
18
23

17
17
22

SAP 115 2 - Dimension


Connection

A/F

H1

H2

H3

A
B
C

G 1
M33x2
G 1 1/2

41
41
55

171
171
176

18
18
23

17
17
22

Connection Filtration

H2

H2

H3

H3

Flow rate with p: 0,02 bar

A/F

A/F
A

116

116

G 1
M33x2

G 1 1/2

40

L10

A03
L10

A03

lN/min
lN/min
SAP 115 1 SAP 115 2
2170
1830

2800
2800

2330
1995

3000
3000

Spar e par ts
3a
1

TAP SAP 115 spare parts


Q.ty

Filler cap series


SAP 115

Complete filler cap

See order table

Filter Element

See order tablee

Indicator kit

Visual indicator

S62P01

3b

Seal

O-R 3106 26,64 X 2,62

3c

Indicator securing screw

01022670

3d

O-R indicator

O-R 2112 28,3 x 1,78

3d

Item.

3b

3c

3a
2

Description

NBR
02005187

FPM
02005188

Changing the filter element in SAP 115 series filler caps

1 Thoroughly clean the filler cap and


adjacent parts.
2 Unscrew and raise the cover.
3 Replace the filter element.
4 Screw the cover.

Or dering i nfor mation


Breather filter

A03

P01

A03

P01

SAP115
Example: SAP115
Filter element
A115

Example: A115
1 - Length

6 - Clogging indicator

4 - Seal

NBR

Without

FPM

Visual indicator

2 - Connection

5 - Variants

7 - Options

G 1

Standard

M33x2

With anti-splash feature

G 1 1/2

P01

MP Filtri standard

3 - Filter element
A03
L10

3 m - Microfibre
10 m - Impregnated paper

41

Metal air breather filter

SA

Series

Dimens ions
1
2
3
H2

4
5

H1

H3

6
A/F

SA (Materials)

1 - Screw: Galvanised Steel

D1

2 - Washer: Teflon
Dimension

3 - Cover: Steel
4 - Filter element: Impregnated paper
5 - Ring: Galvanised Steel
6 - Seal: NBR
7 - Connection: Anodised Aluminium
Galvanised Steel

Flow rate with p: 0,02 bar


Weight

Type

3 m 10 m
lN/min

036
053
075
115
145
185

140
250
350
800
1800
2300

SA 036: 0,080 Kg

Type

D1

H1

H2

H3

A/F (mm)

036
053
075 G1
075 G2
075 G4
075 G5
115
145
185

36
53

13
13
13
17
15
20
17
25
25

36,5
52,5

9
7

68,5

11,5

80
115
164

11
13
23

22
22
27
32
27
32
38
55
80

SA 075: 0,260 Kg
SA 115: 0,400 Kg
SA 145: 0,590 Kg
SA 185: 1,220 Kg

115
145
185

Connection to reservoir A
Type

SA 053: 0,150 Kg

75

140
250
400
850
1850
2500

G1

G2

G3

G4

036 G 1/4 G 3/8 G 1/2


053 G 1/4 G 3/8
075 G 1/2 G 3/4
G 1
115
145 G 1 1/2
185 G 2 1/2

G5

G6

1/4 NPT 3/8 NPT 1/2 NPT


1/4 NPT 3/8 NPT
1/2 NPT 3/4 NPT
1 NPT
1 1/2 NPT
2 1/2 NPT
-

Or der ing infor mation


1

075

G4

L10

P01

Breather filter

A7

L10

Filter element

SA
Example: SA
1 - Size
Filter

Example:

3 - Filter element

2 - Connection to reservoir
Filter element

Type

G1

G2

G3

G4

G5

G6

036

A05

036

G 1/4

G 3/8

G 1/2

1/4 NPT

3/8 NPT 1/2 NPT

053

A5

053

G 1/4

G 3/8

1/4 NPT

3/8 NPT

075

A7

075

G 1/2

G 3/4

1/2 NPT

3/4 NPT

115

A8

115

G 1

1 NPT

145

A10

145 G 1 1/2

1 1/2 NPT

185

A11

185 G 2 1/2

2 1/2 NPT

L03

3 m - Impregnated paper

L10

10 m - Impregnated paper

Without

4 - Seal
A

NBR

5 - Options
P01

42

MP Filtri standard

Series

Metal air breather filter

SCS
Flow rate with p: 0,02 bar
Type

Filtration lN/min
P10

SCS 050

A03
A10

SCS 070

A03
A10

SCS 100

A03
A10

SCS 150

A03
A10

P10

P10

P10
SCS XXX C

550
515
530
550
515
530
1415
1300
1330
1415
1300
1330

SCS XXX F

SCS (Materials)

Weight

Weight

Riser: Galvanised Steel

SCS050...G1: 0,200 Kg

CS/CG050: 0,73 Kg

SCS050...G2: 0,265 Kg

CS/CG070: 0,95 Kg

SCS100...G1: 0,450 Kg

CS100: 1,3 Kg

SCS100...G2: 0,645 Kg

CS150: 1,6 Kg
CG100: 1,3 Kg
CG150: 1,6 Kg

Dimensions SCS - CS - CG
Type

D1

H1

H2

H3

CS/CG050
CS/CG070
CS100
CS150
CG100
CG150

96
96
129
129
129
129

143
210
180
220
180
265

195
262
232
272
232
317

20
20
25
25
30
30

SCS Riser dimensions


Type

D2

D3

SCS050...G1
SCS050...G2
SCS100...G1
SCS100...G2

G 3/4
1 12 UN
G 1 1/4
1 1/2 16 UN

18
18
32
32

32
32
48
48

Dimensions
SCS XXX C

H1
H2

Flange holes for


SCS 050 F

12
0

52

52

60

H1

H2

Flange holes for


SCS 100 F

D1

D1

D2

D2
D3

44

Gasket 42x32x2
(60Sh)
(for SCS 100)

Gasket 42x32x2
(60Sh)
(for SCS 100)

73

41

83

52

H3

H3

SCS XXX F

Or dering i nfor mation

050

G1

A10

P01

050

G1

P01

CS

050

A10

P01

Breather filter
SCS
Example: SCS
Riser
only
SCS
Example: SCS

Filter element
Example:

1 - Filter element type

5 - Filter element

CS

Connection ISO 228 for SCS......G1

A03

3 m - Microfibre

CG

Connection A.S.A. for SCS......G2

A10

10 m - Microfibre

P10

10 m - Impregnated paper

2 - Size
050
070

6 - Seal
Riser assembly excluded

NBR

FPM

100
150

Riser assembly excluded


7 - Options

3 - Connection to reservoir
P01
C

Weld riser

Flange riser

MP Filtri standard

4 - Threaded connection
G1

G 3/4 for SCS 050/070


G 1 1/4 for SCS 100/150

G1 with filter elements series CS


G2

G 3/4 for SCS 050/070


G 1 1/4 for SCS 100/150

G2 with filter elements series CG

45

Potrebbero piacerti anche