Sei sulla pagina 1di 2

Stainless Steel

7-Round HX Cartridge Filter Housings


Specifications
I Liquid Pressure Rating .........150 psig @ 200 F (10.3 bar @ 93 C) I Housing Material .................316 Stainless Steel I Inlet/Outlet Connections .......2-inch (5.1 cm) MNPT standard [3" (7.62 cm) optional]; Victaulic and flanges optional I Pre- and Post-Filter I Gauge Ports..........................1/4-inch (0.6 cm) FNPT ports for inlet and outlet pressure gauges I Upstream Vent Port..............1/4-inch (0.6 cm) FNPT I Drain Port .............................1/2-inch (1.3 cm) MNPT
Shown with optional clamp on stand and pressure gauges.

I O-Ring Material....................Buna-N Standard; EPDM, Silicone, Viton* and Teflon* optional I Cartridge Lengths ................20-, 30-, 40-, or 50-inch filters (51, 76, 102, or 127 cm) I Finish ....................................Satin Finish I Handles.................................Handles included on 30-, 40-, and 50-inch (76, 102, or 127 cm) housing domes

Cartridge Filter Housings


Osmonics Stainless Steel 7-Round Filter Housings combine superior versatility with maximum value to meet the demands of a variety of applications. Each 7-round housing accommodates seven cartridge filters in 20-, 30-, 40- or 50-inch lengths (51, 76, 102, or 127 cm), and up to 2.75-inches (7 cm) in diameter. The innovative housings accept filters with a wide variety of end adapters. In addition, the V-band closure design simplifies cartridge filter replacement.

Features and Benefits


I Stainless Steel Construction .......................................................Proven corrosion resistance and strength. Operating pressure to 150 psig (10.3 bar) at 200 F (93 C). I Side Inlet and Bottom Outlet ......................................................Side inlet is located below the level of the filters, providing non-impinging flow. The bottom outlet allows the housing to be drained completely and reduces the installation space required. I Universal Cup and Post Sealing ..................................................Provides lower seal for cartridge filters with open-end knife-edge type, 222 O-ring, or 120 O-ring end adapters. I Hold-Down Plate ...........................................................................Provides upper seal for cartridge filters with patented Hytrex self seal spring, open-end knife-edge seal (when used with optional stainless steel cup and spring adapters). I V-Clamp Closure ...........................................................................Quick and easy cartridge filter replacement reduces labor costs and downtime. I Clamp-On Stainless Steel Stand .................................................An optional floor mounting stand allows adjustment of the housing height and the level of the inlet and outlet. Height can be adjusted so that the outlet is lower than floor level. I Tungsten Inert Gas (TIG) Welding ............................................... All TIG welding is done at Osmonics factories for the highest quality control.

Housing Specifications
Side View
8.6 in (21.8 cm) vent

Pressure Drop vs. Flow Rate


Top View

(Empty Housing)
0
11.3 in (28.7 cm)

(Shown with optional clamp stand)

12.0 in (30.5 cm)

200

400 Q (Lpm)

600

800

8 ! P (psid) 6
A C 28.1 in (71.4 cm) 2.27 in (5.8 cm) 7.3 in* (18.5 cm) Inlet 4.4 in (11.2 cm) 1.2 in (3.0 cm) Drain 1.1 in (2.8 cm) 12.6 in (32.0 cm)

0.6 2-inch inlet/outlet ! P (bar) 0.5 0.4 0.3 0.2 0.1 0 Q (gpm) 0 50 100 150 200

4 2 0

3-inch inlet/outlet

6.1 in (15.5 cm) B Outlet

1.8 in (4.7 cm)

6.1 in 5.6 in (15.5 cm) (14.2 cm)

B: Bottom of outlet can be as high as 10 inches (25.4 cm) above the floor or as low as 7.5 inches (19.0 cm) below the floor if mounted over a trench. * 8.4 inch (21.3 cm) with flange connection.

Model HX720-_____-316-A HX730-_____-316-A HX740-_____-316-A HX750-_____-316-A

Flow Capacity** gpm (Lpm) to 70 to 105 to 140 to 175 (265) (397) (530) (662)

lb

Weight (kg) (29) (33) (37) (41)

A Length** inch (cm) 40 50 60 70 (102) (127) (152) (178)

"C" Overall height required for cartridge removal*** inch (cm) 54 68 88 108 (137) (173) (224) (274)

64 72 81 90

** Flow rate is dependent upon cartridge filter selection, fluid properties, and maximum acceptable pressure drop. *** Based on B = 5 inches (12.7 cm) on dimensional drawing (this dimension is adjustable). Add 1 inch for housings with flanged ports.

Ordering Information
Sample: HX740-2.0T-316-A-222
HX 7
Hytrex Filter Housing

I
Cartridge Length 20-inch 30-inch 40-inch 50-inch

I
Inlet/ Outlet Size 2.0 -inch 3.0 -inch

316

A
Housing Material 316SS V-Band Clamp Closure

Number of Cartridges per Housing

Port Type V=Victaulic (optional) T=MNPT (standard) F=Flange (optional)

Accessories: Clamp-on legs, cup and spring assemblies (for double-open-end cartridges), pressure gauges, and threaded or victaulic flanges are ordered separately.

For More Information: Call Osmonics Process Water Group at (952) 933-2277 or (800) 848-1750, or visit www.osmonics.com

North American Sales 5951 Clearwater Drive Minnetonka, MN 55343-8995 USA (952) 933-2277 Phone (952) 988-6060 Fax

Euro/African Sales 230 rue Robert Schuman ZA des Uselles 77350 Le Me sur Seine FRANCE +33 1 64 10 2000 Phone +33 1 64 10 3747 Fax

Asian/Pacific Sales 1044/8 SOI 44/2 Sukhumvit Road Prakanong Bangkok 10110 THAILAND +66 2 38 14213 Phone +66 2 39 18183 Fax