Sei sulla pagina 1di 5

HVU adhesive with HAS rod

Features:
- foil capsule vs. glass
- flexible for inserting into crooked / irregular holes

HVU capsule

- pre-setting / through-setting
- specials lengths available on request
- test reports: fire, dynamic (fatigue, shock, seismic),
water tightness

HAS, HAS-R, HAS-HCR

Material:
HVU:
HAS, HAS-E:

- urethane methacrylate resin styrene free, hardener,


quartz sand or corundum, foil tube
- grade 5.8 and 8.8, ISO 898 T1, galvanised to min.
5 microns

HAS-R / -ER:

- stainless steel; A4-70; 1.4401, 1.4404, 1.4571

HAS-HCR:

- stainless steel; 1.4529

HAS-E, HAS-E-R

Small edge
distance /
spacing

Concrete

A4
316

Fatigue

Seismic

HCR

highMo

Corrosion
resistance

High
corrosion Fire resistance
resistance

Hilti Anchor
programme

Basic loading data (for a single anchor): HVU capsule with HAS, HAS-E
All data on this page applies to
For detailed design method, see pages 204 208.
! concrete: See table below.
! correct setting (See setting operations page 203)
! no edge distance and spacing influence
! steel failure: steel grade 5.8 for M8 M24 sizes and steel grade 8.8 for M27 M39

non-cracked concrete
Mean ultimate resistance, Ru,m [kN]: concrete " C20/25
Anchor size!
Tensile, NRu,m
Shear, VRu,m

M8
17.7
10.7

M10
28.2
17.0

M12
41.1
24.7

M16
77.9
46.7

M20
121.7
72.9

M24
175.2
105.0

M27
320.1
221.4

M30
305.1
269.1

M33
498.6
335.3

M36
534.0
393.5

M39
621.6
473.3

M33
440.9
310.5

M36
494.0
364.4

M39
503.2
438.3

Characteristic resistance, Rk [kN]: concrete " C20/25


Anchor size!
Tensile, NRk
Shear, VRk

M8
16.4
9.9

M10
26.1
15.8

M12
38.1
22.9

M16
72.2
43.2

M20
112.7
67.5

M24
162.0
97.3

M27
182.4
205.0

M30
228.0
249.1

Following values according to the

Concrete Capacity Method


Design resistance, Rd [kN]: concrete, fck,cube = 25 N/mm2
Anchor size!
Tensile, NRd
Shear, VRd

M8
10.9
7.9

M10
16.6
12.6

M12
23.8
18.3

M16
34.7
34.6

M20
62.9
54.0

M24
90.6
77.8

M27
110.9
164.0

M30
145.6
199.3

M33
171.0
248.4

M36
203.3
291.5

M39
232.9
350.6

M27
79.2
117.1

M30
104.0
142.4

M33
122.1
177.4

M36
145.2
208.2

M39
166.4
250.4

Recommended load, Lrec [kN]: concrete, fck,cube = 25 N/mm2


Anchor size!
Tensile, NRec
Shear, VRec

185

M8
7.8
5.6

M10
11.8
9.0

M12
17.0
13.1

M16
24.8
24.7

M20
44.9
38.6

M24
64.7
55.6

HVU adhesive with HAS rod


Basic loading data (for a single anchor): HVU capsule with HAS-R, HAS-E-R, HAS-HCR
All data on this section applies to
For detailed design method, see pages 204 208.
! concrete: See table below.
! correct setting (See setting operations page 203)
! no edge distance and spacing influence
! steel failure: steel grade A4-70 for M8 M24; for A4 grade, fuk changes for the sizes M27 to M39 from
700 N/mm2 to 500 N/mm2.

non-cracked concrete
Mean ultimate resistance, Ru,m [kN]: concrete " C20/25
Anchor size!
Tensile, NRu,m
Shear, VRu,m

M8
24.8
14.8

M10
39.6
23.8

M12
57.8
34.5

M16
109.1
65.4

M20
170.3
102.1

M24
244.4
146.9

M27
230.7
138.5

M30
280.2
168.3

M33
349.4
209.7

M36
410.1
246.0

M39
493.0
295.9

M24
226.3
136.0

M27
213.6
128.2

M30
259.4
155.8

M33
323.5
194.2

M36
379.7
227.8

M39
456.5
274.0

Characteristic resistance, Rk [kN]: concrete " C20/25


Anchor size!
Tensile, NRk
Shear, VRk

M8
23.0
13.7

M10
36.7
22.0

M12
53.5
32.0

M16
101.0
60.5

M20
157.6
94.5

Following values according to the

Concrete Capacity Method


Design resistance, Rd [kN]: concrete, fck,cube = 25 N/mm2
Anchor size!
Tensile, NRd
Shear, VRd

M8
12.3
8.8

M10
16.6
14.1

M12
23.8
20.5

M16
34.7
38.8

M20
62.9
60.6

M24
90.6
87.2

M27
89.0
64.1

M30
108.1
77.9

M33
134.8
97.1

M36
158.2
113.9

M39
190.2
137.0

M27
63.6
45.8

M30
77.2
55.6

M33
96.3
69.4

M36
113.0
81.3

M39
135.9
97.9

Recommended load, Lrec [kN]: concrete, fck,cube = 25 N/mm2


Anchor size!
Tensile, NRec
Shear, VRec

M8
8.8
6.3

M10
11.8
10.1

M12
17.0
14.6

M16
24.8
27.7

M20
44.9
43.3

M24
64.7
62.3

187

HVU adhesive with HAS rod


Setting details

df
d0

t fix

h1
h min

Anchor size
Foil capsule
Anchor rod

1)

M8

M16

M20

M24

M27

M30

M33

M36

M39

M10x90 M12x110 M16x125 M20x170 M24x210 M27x240 M30x270 M33x300 M36x330 M39x360

HAS /-E/-R/-ER/-HCR

M8x80/
14

M10x90/ M12x110/ M16x125/ M20x170/ M24x210/ M27x240/ M30x270/ M33x300/ M36x330/ M39x360/
21
28
38
48
54
60
70
80
90
100

Drill bit diameter

h1=hnom

Hole depth =
[mm]
Embedment depth

tfix (max)

M12

M8x80

d0

h (min)

M10

HVU

[mm]

10

12

14

18

24

28

30

35

37

40

42

80

90

110

125

170

210

240

270

300

330

360

[mm]

110

120

140

170

220

270

300

340

380

410

450

[mm]

14

21

28

38

48

54

60

70

80

90

100

rec. [mm]
max. [mm]

9
11

12
13

14
15

18
19

22
25

26
29

30
31

33
36

36
38

39
41

42
43

15

30

50

100

160

240

270

300

1200

1500

1800

10/22

12/22

14/22

18/32

24/32

28/52

30/57

Min. thickness
of base material
Max. fixture
thickness

df

Clearance
hole

Tinst

Tightening torque [Nm]


TE-CX-

Drill bit
TE-TRec. diamond drilling machine
1)

DD 100 // DD 160 E

The values for the maximum fixture thickness are only valid for the HAS anchor rods given in this table.
If other HAS rods are used, these values will change. (Example: HAS M12x110/128; tfix = 128 mm)

1)

Temperature when setting:


20C and above
10C to 20C
0C to 10C
-5C to 0C
1)

DD EC-1

Min. time to wait before


removing SCREWED-ON
setting tool,
trel
8 min.
20 min.
30 min.
60 min.

Curing timebefore anchor can


be fully loaded,
tcure
20 min.
30 min.
60 min.
5 hours

If the temperature is less than 5C, contact your Hilti technical service.

Installation equipment
Rotary hammer (TE1, TE 2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE 35, TE 55 or TE 76) or a diamond
drilling machine, a drill bit, a TE-C HEX, TE-C-E TE-Y-E setting tool and a blow-out pump.

187

HVU with HAS adhesive anchor


Setting operations
1

4
5

HAS

HVU

Blow out dust and


fragments.

Drill hole.

trel

Allow gel time to pass.

Insert HVU capsule.

tcure

Drive in anchor.

7
Tinst

Apply tightening
torque.

Wait for curing.

HVU M..

Sw

d
dpp

dw

Anchor geometry and mechanical properties

HVU M..

HVU M..

l lpp
Anchor size

l
M8

Foil capsule

HVU

M8x80

M10

M12

M16

M20

M24

M27

M30

M33

M36

M39

M10x90 M12x110 M16x125 M20x170 M24x210 M27x240 M30x270 M33x300 M36x330 M39x360

lp [mm]

HVU capsule length

110

110

127

140

170

200

225

260

290

320

350

dp [mm]

HVU capsule diameter

9.3

10.7

13.1

17.1

22.0

25.7

26.8

31.5

31.5

32.0

35.0

Anchor rod
l

[mm]
2

As [mm ]

HAS

M8x80/
14

M10x90/ M12x110/ M16x125/ M20x170/ M24x210/ M27x240/ M30x270/ M33x300/ M36x330/ M39x360/
21
28
38
48
54
60
70
80
90
100

Anchor length

110

130

160

190

240

290

340

380

420

460

510

Stressed cross-section

32.8

52.3

76.2

144

225

324

427

519

647

759

913

HAS 5.8

500

500

500

500

500

500

HAS 8.8

800

800

800

800

800

700

700

700

700

700

700

500

500

500

500

500

HAS 5.8

400

400

400

400

400

400

HAS 8.8

640

640

640

640

640

450

450

450

450

450

450

250

250

250

250

250

26.5

53.3

93.9

244

477

824

1245

1668

2322

2951

3860

HAS 5.8

12.7

25.6

45.1

117.1

228.8

395.3

HAS 8.8

956.1

1280.8 1783.5 2266.5 2987.8

14.3

28.7

50.6

131.4

256.7

443.5

478.8

641.5

893.0

fuk [N/mm ] Nominal tensile


strength

HAS-R
-HCR

fyk [N/mm ] Yield strength

HAS-R
-HCR
3

W [mm ]

MRd,s [Nm]

Moment of resistance

Design bending
1)
resistance

HAS-R

1134.9 1484.5

-HCR
Sw [mm]

Width across flats

13

17

19

24

30

36

41

46

50

55

59

dw [mm]

Washer diameter

16

20

24

30

37

44

50

56

60

66

72

1)

The design bending resistance of the anchor rod is calculated from MRd,s = (1.2 W fuk)/#Ms,b , where the partial safety factor, #Ms,b , for
grade 5.8 and 8.8 rods is 1.25 and for 1.56 for A4-70 and HCR. The final safety check is then MSk #F $ MRd,s

188

page 4 of 9

HVA ADHESIVE ANCHOR


Detailed design method - Hilti CC
(The Hilti CC method is a simplified version of ETAG Annex C.)

Caution: In view of the high loads transferable with HVU, it must be verified by the user that the load acting on
the concrete structure, including the loads introduced by the anchor fastening, do not cause failure, e.g.
cracking, of the concrete structure.
N rec,c/s

TENSION

The design tensile resistance of a single anchor


is the lower of
NRd,c : concrete cone/pull-out resistance
NRd,s : steel resistance

NRd,c: Concrete cone/pull-out resistance


o
NRd,c & NRd
,c % fB,N % f T % f A,N % fR,N

N0Rd,c : Concrete cone/pull-out design resistance


Concrete compressive strength, fck,cube(150) = 25 N/mm2

Anchor size
0
1)
Rd,c

hnom
1)

[kN]
[mm]

Nominal anchorage depth

M8

M10

M12

M16

M20

M24

M27

M30

M33

M36

M39

12.4

16.6

23.8

34.7

62.9

90.6

110.9

145.6

171.0

203.3

232.9

80

90

110

125

170

210

240

270

300

330

360

The design tensile resistance is calculated from the characteristic tensile resistance, NRk,c , by NRd,c = NRk,c/#Mc,N, where the
partial safety, #Mc,N , factor is 1.8.

fB,N : Influence of concrete strength


Designation of
grade of
concrete

Cylinder
compressive
strength,

Cube compressive

(ENV 206)

fck,cyl [N/mm]

fck,cube [N/mm]

C16/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60

16
20
25
30
35
40
45
50

20
25
30
37
45
50
55
60

Concrete cylinder:

Concrete cube:

height 30cm, 15cm

side length 15cm

, fck,cube - 25 )
'
80
+
(

fB,N & 1 . *

strength,
fB,N
0.94
1
1.05
1.12
1.20
1.25
1.30
1.35

for fck,cube= 20N/mm

- 25 )
,f
''
fB,N & 1 . ** ck,cube
100
+
(

Limits:
25 N/mm $ fck,cube $ 60 N/mm

diameter
Concrete test specimen geometry

189

Potrebbero piacerti anche