Features:
- foil capsule vs. glass
- flexible for inserting into crooked / irregular holes
HVU capsule
- pre-setting / through-setting
- specials lengths available on request
- test reports: fire, dynamic (fatigue, shock, seismic),
water tightness
Material:
HVU:
HAS, HAS-E:
HAS-R / -ER:
HAS-HCR:
HAS-E, HAS-E-R
Small edge
distance /
spacing
Concrete
A4
316
Fatigue
Seismic
HCR
highMo
Corrosion
resistance
High
corrosion Fire resistance
resistance
Hilti Anchor
programme
Basic loading data (for a single anchor): HVU capsule with HAS, HAS-E
All data on this page applies to
For detailed design method, see pages 204 208.
! concrete: See table below.
! correct setting (See setting operations page 203)
! no edge distance and spacing influence
! steel failure: steel grade 5.8 for M8 M24 sizes and steel grade 8.8 for M27 M39
non-cracked concrete
Mean ultimate resistance, Ru,m [kN]: concrete " C20/25
Anchor size!
Tensile, NRu,m
Shear, VRu,m
M8
17.7
10.7
M10
28.2
17.0
M12
41.1
24.7
M16
77.9
46.7
M20
121.7
72.9
M24
175.2
105.0
M27
320.1
221.4
M30
305.1
269.1
M33
498.6
335.3
M36
534.0
393.5
M39
621.6
473.3
M33
440.9
310.5
M36
494.0
364.4
M39
503.2
438.3
M8
16.4
9.9
M10
26.1
15.8
M12
38.1
22.9
M16
72.2
43.2
M20
112.7
67.5
M24
162.0
97.3
M27
182.4
205.0
M30
228.0
249.1
M8
10.9
7.9
M10
16.6
12.6
M12
23.8
18.3
M16
34.7
34.6
M20
62.9
54.0
M24
90.6
77.8
M27
110.9
164.0
M30
145.6
199.3
M33
171.0
248.4
M36
203.3
291.5
M39
232.9
350.6
M27
79.2
117.1
M30
104.0
142.4
M33
122.1
177.4
M36
145.2
208.2
M39
166.4
250.4
185
M8
7.8
5.6
M10
11.8
9.0
M12
17.0
13.1
M16
24.8
24.7
M20
44.9
38.6
M24
64.7
55.6
non-cracked concrete
Mean ultimate resistance, Ru,m [kN]: concrete " C20/25
Anchor size!
Tensile, NRu,m
Shear, VRu,m
M8
24.8
14.8
M10
39.6
23.8
M12
57.8
34.5
M16
109.1
65.4
M20
170.3
102.1
M24
244.4
146.9
M27
230.7
138.5
M30
280.2
168.3
M33
349.4
209.7
M36
410.1
246.0
M39
493.0
295.9
M24
226.3
136.0
M27
213.6
128.2
M30
259.4
155.8
M33
323.5
194.2
M36
379.7
227.8
M39
456.5
274.0
M8
23.0
13.7
M10
36.7
22.0
M12
53.5
32.0
M16
101.0
60.5
M20
157.6
94.5
M8
12.3
8.8
M10
16.6
14.1
M12
23.8
20.5
M16
34.7
38.8
M20
62.9
60.6
M24
90.6
87.2
M27
89.0
64.1
M30
108.1
77.9
M33
134.8
97.1
M36
158.2
113.9
M39
190.2
137.0
M27
63.6
45.8
M30
77.2
55.6
M33
96.3
69.4
M36
113.0
81.3
M39
135.9
97.9
M8
8.8
6.3
M10
11.8
10.1
M12
17.0
14.6
M16
24.8
27.7
M20
44.9
43.3
M24
64.7
62.3
187
df
d0
t fix
h1
h min
Anchor size
Foil capsule
Anchor rod
1)
M8
M16
M20
M24
M27
M30
M33
M36
M39
M10x90 M12x110 M16x125 M20x170 M24x210 M27x240 M30x270 M33x300 M36x330 M39x360
HAS /-E/-R/-ER/-HCR
M8x80/
14
M10x90/ M12x110/ M16x125/ M20x170/ M24x210/ M27x240/ M30x270/ M33x300/ M36x330/ M39x360/
21
28
38
48
54
60
70
80
90
100
h1=hnom
Hole depth =
[mm]
Embedment depth
tfix (max)
M12
M8x80
d0
h (min)
M10
HVU
[mm]
10
12
14
18
24
28
30
35
37
40
42
80
90
110
125
170
210
240
270
300
330
360
[mm]
110
120
140
170
220
270
300
340
380
410
450
[mm]
14
21
28
38
48
54
60
70
80
90
100
rec. [mm]
max. [mm]
9
11
12
13
14
15
18
19
22
25
26
29
30
31
33
36
36
38
39
41
42
43
15
30
50
100
160
240
270
300
1200
1500
1800
10/22
12/22
14/22
18/32
24/32
28/52
30/57
Min. thickness
of base material
Max. fixture
thickness
df
Clearance
hole
Tinst
Drill bit
TE-TRec. diamond drilling machine
1)
DD 100 // DD 160 E
The values for the maximum fixture thickness are only valid for the HAS anchor rods given in this table.
If other HAS rods are used, these values will change. (Example: HAS M12x110/128; tfix = 128 mm)
1)
DD EC-1
If the temperature is less than 5C, contact your Hilti technical service.
Installation equipment
Rotary hammer (TE1, TE 2, TE5, TE6, TE6A, TE15, TE15-C, TE18-M, TE 35, TE 55 or TE 76) or a diamond
drilling machine, a drill bit, a TE-C HEX, TE-C-E TE-Y-E setting tool and a blow-out pump.
187
4
5
HAS
HVU
Drill hole.
trel
tcure
Drive in anchor.
7
Tinst
Apply tightening
torque.
HVU M..
Sw
d
dpp
dw
HVU M..
HVU M..
l lpp
Anchor size
l
M8
Foil capsule
HVU
M8x80
M10
M12
M16
M20
M24
M27
M30
M33
M36
M39
M10x90 M12x110 M16x125 M20x170 M24x210 M27x240 M30x270 M33x300 M36x330 M39x360
lp [mm]
110
110
127
140
170
200
225
260
290
320
350
dp [mm]
9.3
10.7
13.1
17.1
22.0
25.7
26.8
31.5
31.5
32.0
35.0
Anchor rod
l
[mm]
2
As [mm ]
HAS
M8x80/
14
M10x90/ M12x110/ M16x125/ M20x170/ M24x210/ M27x240/ M30x270/ M33x300/ M36x330/ M39x360/
21
28
38
48
54
60
70
80
90
100
Anchor length
110
130
160
190
240
290
340
380
420
460
510
Stressed cross-section
32.8
52.3
76.2
144
225
324
427
519
647
759
913
HAS 5.8
500
500
500
500
500
500
HAS 8.8
800
800
800
800
800
700
700
700
700
700
700
500
500
500
500
500
HAS 5.8
400
400
400
400
400
400
HAS 8.8
640
640
640
640
640
450
450
450
450
450
450
250
250
250
250
250
26.5
53.3
93.9
244
477
824
1245
1668
2322
2951
3860
HAS 5.8
12.7
25.6
45.1
117.1
228.8
395.3
HAS 8.8
956.1
14.3
28.7
50.6
131.4
256.7
443.5
478.8
641.5
893.0
HAS-R
-HCR
HAS-R
-HCR
3
W [mm ]
MRd,s [Nm]
Moment of resistance
Design bending
1)
resistance
HAS-R
1134.9 1484.5
-HCR
Sw [mm]
13
17
19
24
30
36
41
46
50
55
59
dw [mm]
Washer diameter
16
20
24
30
37
44
50
56
60
66
72
1)
The design bending resistance of the anchor rod is calculated from MRd,s = (1.2 W fuk)/#Ms,b , where the partial safety factor, #Ms,b , for
grade 5.8 and 8.8 rods is 1.25 and for 1.56 for A4-70 and HCR. The final safety check is then MSk #F $ MRd,s
188
page 4 of 9
Caution: In view of the high loads transferable with HVU, it must be verified by the user that the load acting on
the concrete structure, including the loads introduced by the anchor fastening, do not cause failure, e.g.
cracking, of the concrete structure.
N rec,c/s
TENSION
Anchor size
0
1)
Rd,c
hnom
1)
[kN]
[mm]
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
M39
12.4
16.6
23.8
34.7
62.9
90.6
110.9
145.6
171.0
203.3
232.9
80
90
110
125
170
210
240
270
300
330
360
The design tensile resistance is calculated from the characteristic tensile resistance, NRk,c , by NRd,c = NRk,c/#Mc,N, where the
partial safety, #Mc,N , factor is 1.8.
Cylinder
compressive
strength,
Cube compressive
(ENV 206)
fck,cyl [N/mm]
fck,cube [N/mm]
C16/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
16
20
25
30
35
40
45
50
20
25
30
37
45
50
55
60
Concrete cylinder:
Concrete cube:
, fck,cube - 25 )
'
80
+
(
fB,N & 1 . *
strength,
fB,N
0.94
1
1.05
1.12
1.20
1.25
1.30
1.35
- 25 )
,f
''
fB,N & 1 . ** ck,cube
100
+
(
Limits:
25 N/mm $ fck,cube $ 60 N/mm
diameter
Concrete test specimen geometry
189