Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
I n t e l e C o o l 2
Cellular Radio Paging Microwave/Satellite Earth Stations PCS Services Mobile/Modular Electronic Equipment Structures
The InteleCool 2 is designed with the flexibility to match the multiple protection needs of todays telecommunications industry. You pick the level of protection your application requires and Liebert will configure an InteleCool 2 for you...
Basic Cooling
For shelters that are less critical and located close to service capability, minimum seasonal air conditioning is usually sufficient. Depending on the application, single or redundant units may be used. A simple remote monitoring capability may also be added.
Critical Shelters
Shelters with highly sensitive equipment and limited site access must keep operating no matter what. These sites may require dual units, high-reliability components such as a scroll compressor, energy saving capabilities such as an economizer, heating, remote monitoring and switchover control. The InteleCool 2 T-Pack is designed for these types of common telecommunications shelters. This package includes the basic InteleCool 2 system with all of the most popular options including high and low pressure switches, fan cycle control and low pressure bypass.
Special Locations
You dont always have a choice as to where to place a telecom shelter. It may be located in an urban environment where noise, appearance and other factors are important. Or it may be miles from nowhere on the side of a mountainmaking absolute reliability an important requirement.
NOW YOU CAN CUSTOM-CONFIGURE SHELTER AIR CONDITIONING TO YOUR EXACT NEEDS AND BUDGET
4
Maximum Flexibility Designed To Meet All Your Shelter Cooling Requirements
This simple, seven-step process can determine your needs and configure protection to match those needs exactly.
No more wondering why you paid for all those features you dont use...or lamenting that you could have saved a lot of problems if you only added that one little feature when you had it installed.
Aluminum
Step 2: Cabinet
The self-contained InteleCool 2 cabinets come with your choice of painted steel or aluminum panels. Painted steel panels are available in a choice of four different colors. The evaporator supply and return openings match industry standard dimensions for ease of installation.
Tan
Step 3: Compressor
The InteleCool 2 offers a choice of compressors to match your specific reliability needs. A rugged hermetic compressor is standard on the 1.5, 2 and 3 ton units. For applications requiring the highest reliability and lower energy use, a scroll compressor is also available as an option on the 1.5, 2 and 3 ton sizes and is standard equipment on the 4 and 5 ton capacity models. With fewer moving parts and continuous compression, the scroll compressor is 14% more efficient than hermetic units. It operates at an EER level of 11.3 one of the highest in the industry. The scroll compressor is also ideal in applications where noise is a factor thanks to its low noise and vibration.
Almond
Bright White
Scroll
Hermetic
Desert Brown
Compressors can also be located on either the right or left side of the unit to make it easier to service dual installations.
5
6
4 6
No Economizer
When outside temperatures are warmer than the inside air, the Economizer is closed and indoor air is recirculated to maintain proper cooling.
Full Economizer
The Economizer takes advantage of low outdoor ambients, drawing on this cool air to maintain indoor temperatures. The result is cooling at lower energy costs, also saving wear on components.
Modulated
In Modulated mode, the Economizer draws cool outside air and recirculates indoor air, reducing compressor run time.
Step 6: Controls
The high quality thermostat senses ambient temperature and compares it to your predetermined requirements. For the highest levels of reliability
and to minimize site downtime critical shelters can be equipped with two InteleCool 2 units and an autochangeover system that balances runtime and automatically switches from one unit to another in case of a system failure. Dual operation can be accomplished with either the Dual Unit Control thermostat or the Tele2 control and monitoring system.
Specifications
60Hz Models 95F Outdoor Ambient ET018 Compressor Type Hermetic Scroll 80/67F 26.7/19.4C Total BTU/H 19300 19200 Total kW 5.65 5.63 Sensible BTU/H 17200 17200 Sensible kW 5.04 5.04 75/62.5F 23.9/16.9C Total BTU/H 17800 17900 Total kW 5.22 5.24 Sensible BTU/H 16600 16600 Sensible kW 4.86 4.86 Weight (Standard Unit) lbs.(kg) 330 (150) (Unit w/Economizer) lbs.(kg) 350 (159) 50Hz Models 95F Outdoor Ambient ET017 Compressor Type Hermetic Scroll 80/67F 26.7/19.4C Total BTU/H 16500 19200 Total kW 4.83 5.63 Sensible BTU/H 14700 15800 Sensible kW 4.31 4.63 75/62.5F 23.9/16.9C Total BTU/H 15300 18000 Total kW 4.48 5.27 Sensible BTU/H 14200 15300 Sensible kW 4.16 4.48 Weight (Standard Unit) lbs.(kg) 330 (150) (Unit w/Economizer) lbs.(kg) 350 (159) ET024 Hermetic Scroll 23200 6.80 19100 5.60 21500 6.30 18400 5.39 22400 6.56 18800 5.51 20900 6.12 18200 5.33 ET036 Hermetic Scroll 33800 9.90 26100 7.65 31400 9.20 25300 7.41 34600 10.14 26400 7.74 32300 9.46 25700 7.53 ET048/ET348 Scroll 46900 13.74 38400 11.25 43800 12.83 37300 10.93 470( 213) 490( 222) ET060/ET360 Scroll 56000 16.41 41900 12.28 52400 15.35 40800 11.95 470 (213) 490 (222)
ET023 Hermetic Scroll 19900 5.83 16500 4.83 18400 5.39 15900 4.66 21600 6.33 17100 5.01 20100 5.89 16600 4.86
ET035 Hermetic Scroll 28800 8.44 22300 6.53 26800 7.85 21700 6.36 27700 8.12 21900 6.42 25900 7.59 21300 6.24
ET047/ET347 Scroll 39800 11.66 32500 9.52 37200 10.90 31600 9.26 470( 213) 490( 222)
ET059/ET359 Scroll 49000 14.36 36000 10.55 45900 13.45 35100 10.28 470 (213) 490 (222)
The ET3 Series of InteleCool 2 is designed as a field replacement/upgrade of a 3 ton air conditioner to a 4 or 5 ton using existing air openings. This allows a unit with more cooling capacity to be installed quickly and easily. No cutting or sawing of the shelter is required.
Ws Wu E
J G A
SUPPLY
B
RETURN
Model Wu Ws Wf A B E F G H J 1.5/2 Ton 37.1(943) 17.8(451) 38.8(984) 20.0(508) 20.0(508) 8.0(203) 20.8(527) 12.0(305) 25.1(638) 69.8(1772) 3 Ton 37.1(943) 17.8(451) 38.8(984) 28.0(711) 28.0(711) 8.0(203) 18.0(457) 14.0(356) 26.0(660) 69.8(1772) 4/5 Ton with 3 ton openings 41.0(1041) 22.5(572) 42.75(1086) 30.3(768) 28.0(711) 8.0(203) 18.0(457) 14.0(356) 37.5(952) 83.0(2108)
Wu= unit width Wf=width to flange edges A=height to top of flange
Shaded areas indicate a recommended clearance of 34 (864mm) in front and 30 (762mm) each side or 36 (914mm) each side when mounted adjacent to another unit for component access. For recommended minimum clearances refer to the installation manual.
L I E B E R T CO R P O R AT I O N
1050 DEARBORN DRIVE P.O. BOX 29186 COLUMBUS, OHIO 43229 800.877.9222 PHONE (U.S. & CANADA ONLY) 614.888.0246 PHONE (OUTSIDE U.S.) 614.841.6022 FAX VIA LEONARDO DA VINCI 8 ZONA INDUSTRIALE TOGNANA 35028 PIOVE DI SACCO (PD) ITALY 39 049 9719 111 PHONE 39 049 5841 257 FAX EMERSON NETWORK POWER ASIA PACIFIC 7/F., DAH SING FINANCIAL CENTRE 108 GLOUCESTER RD, WANCHAI HONG KONG 852 25722201 PHONE 852 28029250 FAX
24
7 TECH SUPPORT
The day your critical operations are threatened by excessive heat, power problems or other risks is no time to find out if a "simple" solution to system protection will work. Let Liebert help you make the smart decision about assuring reliability in your high availability facilities.
While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 2004 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. Liebert and the Liebert logo are registered trademarks of the Liebert Corporation. Keeping Business in Business is a registered trademark of the Liebert Corporation. The Emerson logo is a trademark and service mark of Emerson Electric Co. SL-19500 (R3/04) Printed in USA